FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. MMD Hong Kong Holding Limited/
  3. 2AR2STAB7807RESW

2AR2STAB7807RESWWireless subwoofer

MMD Hong Kong Holding Limited
Wireless subwoofer - FCC ID 2AR2STAB7807RESW - MMD Hong Kong Holding Limited
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Apr 24, 2022
Application Purpose
Original Equipment
Date of Application
Apr 24, 2022
Equipment Note
Wireless subwoofer
Frequency Range
2402.00000000 - 2480.00000000
Company
MMD Hong Kong Holding Limited
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

User manual Register your product and get support at www.philips.com/support TAB7807 7000 Series Soundbar FPO 2EN Contents 1 Important safety instructions 3 Safety 3 Care for your product 4 Care of the environment 4 Compliance 4 Help and support 4 2 Your Soundbar 6 What’s in the box 6 Main unit 6 Connectors 7 Wireless subwoofer 7 Remote control 8 Prepare the remote control 8 Placement 9 Wall mount 10 3 Connect 11 Dolby Atmos® 11 Connect to HDMI Socket 11 Connect to Optical Socket 12 Connect to Audio in Socket 12 Connect to Power 13 Pair up with the Subwoofer 13 4 Use your Soundbar 14 Turn ON and OFF 14 Select Modes 14 Adjust the Volume 14 Dolby Sound Mode 14 Setup Menu 14 Factory Reset 16 Bluetooth Operation 16 HDMI in / HDMI eARC Optical / Audio in / Operation 17 USB Operation 18 5 Product specifications 19 6 Troubleshooting 21 Trademarks: 23 3EN 1 Important safety instructions Read and understand all instructions before you use your product. If damage is caused by failure to follow instructions, the warranty does not apply. Safety Risk of electric shock or fire! • Before you make or change any connections, make sure that all devices are disconnected from the power outlet. • Never expose the product and accessories to rain or water. Never place liquid containers, such as vases, near the product. If liquids are spilt on or into the product, disconnect it from the power outlet immediately. Contact Consumer Care to have the product checked before use. • Never place the product and accessories near naked flames or other heat sources, including direct sunlight. • Never insert objects into the ventilation slots or other openings on the product. • Where the mains plug or an appliance coupler is used as the disconnect device, the disconnect device shall remain readily operable. • Battery (battery pack or batteries installed) shall not be exposed to excessive heat such as sunshine, fire or the like. • Disconnect the product from the power outlet before lightning storms. • When you disconnect the power cord, always pull the plug, never the cable. • Use the product in tropical and/or moderate climates. Risk of short circuit or fire! • For identification and supply ratings, see the type plate at the back or bottom of the product. • Before you connect the product to the power outlet, ensure that the power voltage matches the value printed on the back or bottom of the product. Never connect the product to the power outlet if the voltage is different. Risk of injury or damage to this product! • For wall mounting, this product must be securely attached to the wall in accordance with the installation instructions. Use only the supplied wall mount bracket (if available). Improper wall mounting may result in accident, injury or damage. If you have any query, contact Consumer Care in your country. • Never place the product or any objects on power cords or on other electrical equipment. • If the product is transported in temperatures below 5°C, unpack the product and wait until its temperature matches room temperature before connecting it to the power outlet. • Parts of this product can be made of glass. Handle with care to avoid injury and damage. Risk of overheating! • Never install this product in a confined space. Always leave a space of at least four inches around the product for ventilation. Ensure curtains or other objects never cover the ventilation slots on the product. Risk of contamination! • Do not mix batteries (old and new or carbon and alkaine, etc.). 4EN • CAUTION: Danger of explosion if batteries are incorrectly replaced. Replace only with the same or equivalent type. • Remove batteries if they are exhausted or if the remote control is not to be used for a long time. • Batteries contain chemical substances, they should be disposed of properly. This is CLASS II apparatus with double insulation, and no protective earth provided. AC voltage Follow the instructions in the user manual! WARNING! Warning: risk of electric shock! The exclamatory mark is intended to alert the user to the presence of important operating instructions. Note • The rating label is pasted on the bottom or back of the equipment. Care for your product Use only microfiber cloth to clean the product. Care of the environment Disposal of your old product and battery Your product is designed and manufactured with high quality materials and components, which can be recycled and reused. This symbol on a product means that the product is covered by European Directive 2012/19/EU. This symbol means that the product contains batteries covered by European Directive 2013/56/EU which cannot be disposed of with normal household waste. Inform yourself about the local separate collection system for electrical and electronic products and batteries. Follow local rules and never dispose of the product and batteries with normal household waste. Correct disposal of old products and batteries helps prevent negative consequences for the environment and human health. Removing the disposable batteries To remove the disposable batteries, see battery installation section. Compliance This product complies with the radio interference requirements of the European Community. Hereby, TP Vision Europe B.V. declares that this product is in compliance with the essential requirements and other relevant provisions of RED Directive 2014/53/EU and UK Radio Equipment Regulations 2017. You can find the Declaration of Conformity on www.p4c.philips.com. Help and support For extensive online support, visit www.philips.com/support to: • download the user manual and the quick start guide • watch video tutorials (available only for selected models) 5EN • find answers to frequently answered questions (FAQs) • email us a question • chat with our support representative. Follow the instructions on the website to select your language, and then enter your product model number. Alternatively, you can contact Consumer Care in your country. Before you contact, note down the model…

Text truncated - open the document above for the full version.

Cover Letter(s)

MMD Hong Kong Holding Limited Federal Communications Commission Authorization and Evaluation Division 1435 Oakland Mills Road Columbia, MD 21046 Date: 2022-04-06 SUBJECT: 2AR2STAB7807RESW To Whom It May Concern: I, the undersigned, hereby states this equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules, and will apply the Supplier's Declaration of Conformity procedure to the class B computer peripheral portion of this composite device. I understand the following FCC requirements: 1. Devices subject to the SDoC procedure are required to be tested to show compliance with the FCC technical regulations by a recognized accredited testing laboratory. The testing laboratory must be accredited by a Commission approved accreditation body or designated under the terms of a government-to-government Mutual Recognition Agreement (MRA). A listing of those accredited testing laboratories that have been recognized by the Commission is published on the FCC Webpage: https://apps.fcc.gov/oetcf/eas/reports/TestFirmSearch.cfm (Select the "accredited" option to search for FCC recognized accredited test firms.) 2. Pt 2.1077 contains the list of information that must be included in the Supplier's Declaration of Conformity, which must be supplied with each product sold. The SDoC compliance info shall be included in the User’s Manual or as a separate sheet. The info must contain the name, address, and phone number of the responsible party, which must be located within the United States. According to 2.909(b), the responsible party is either the Manufacturer or if the product is imported the Importer. Regards, MMD Hong Kong Holding Limited Signed ------------------------------- (Tomas Guan)

Cover Letter(s)

C:\Users\dell\Desktop\Subwoofer FCC ID+IC ID签字文件\FCC ID签字文件\POA_Letter.docx (MMD Hong Kong Holding Limited) Federal Communications Commission Authorization and Evaluation Division 1435 Oakland Mills Road Columbia, MD 21046 Date: 2022-04-06 SUBJECT: FCC Application for (FCC ID: 2AR2STAB7807RESW) To Whom It May Concern: We, the undersigned, hereby authorize _Harry Li at Hwa-Hsing (Dongguan) Testing Co., Ltd._ on our behalf, to apply to the Federal Communications Commission on our equipment. Any and all acts carried out by _ Harry Li at Hwa-Hsing (Dongguan) Testing Co., Ltd. on our behalf shall have the same effect as acts of our own. This is to advise that we are in full compliance with the Anti- Drug Abuse Act. We, the applicant, are not subject to a denial of federal benefits pursuant to Section 5301 of the Anti-Drug Act of 1988, 21 USC853a, and no party to the application is subject to a denial of federal benefits pursuant to that section. Regards, Tomas Guan Signed (Must be signed by the person that is listed on the FCC Website)

External Photos

Lab: Hwa-Hsing (Dongguan) Testing Co., Ltd. Address: No.101, Bld N1, Yuyuan 2Rd, Yuyuan Industrial Park, HuangJiang Town, Dongguan, China Tel: 0769-83078199 Web.: www.hwa-hsing.com E-Mail: [email protected] Release Ver. 1.4 Page 1 of 3 Project No.: 220218KH03-1-2 External EUT Photo Subwoofer Lab: Hwa-Hsing (Dongguan) Testing Co., Ltd. Address: No.101, Bld N1, Yuyuan 2Rd, Yuyuan Industrial Park, HuangJiang Town, Dongguan, China Tel: 0769-83078199 Web.: www.hwa-hsing.com E-Mail: [email protected] Release Ver. 1.4 Page 2 of 3 Project No.: 220218KH03-1-2 Lab: Hwa-Hsing (Dongguan) Testing Co., Ltd. Address: No.101, Bld N1, Yuyuan 2Rd, Yuyuan Industrial Park, HuangJiang Town, Dongguan, China Tel: 0769-83078199 Web.: www.hwa-hsing.com E-Mail: [email protected] Release Ver. 1.4 Page 3 of 3 Project No.: 220218KH03-1-2

Internal Photos

Lab: Hwa-Hsing (Dongguan) Testing Co., Ltd. Address: No.101, Bld N1, Yuyuan 2Rd, Yuyuan Industrial Park, HuangJiang Town, Dongguan, China Tel: 0769-83078199 Web.: www.hwa-hsing.com E-Mail: [email protected] Release Ver. 1.4 Page 1 of 6 Project No.: 220218KH03-1-1 EUT Photos Subwoofer Lab: Hwa-Hsing (Dongguan) Testing Co., Ltd. Address: No.101, Bld N1, Yuyuan 2Rd, Yuyuan Industrial Park, HuangJiang Town, Dongguan, China Tel: 0769-83078199 Web.: www.hwa-hsing.com E-Mail: [email protected] Release Ver. 1.4 Page 2 of 6 Project No.: 220218KH03-1-1 Lab: Hwa-Hsing (Dongguan) Testing Co., Ltd. Address: No.101, Bld N1, Yuyuan 2Rd, Yuyuan Industrial Park, HuangJiang Town, Dongguan, China Tel: 0769-83078199 Web.: www.hwa-hsing.com E-Mail: [email protected] Release Ver. 1.4 Page 3 of 6 Project No.: 220218KH03-1-1 Lab: Hwa-Hsing (Dongguan) Testing Co., Ltd. Address: No.101, Bld N1, Yuyuan 2Rd, Yuyuan Industrial Park, HuangJiang Town, Dongguan, China Tel: 0769-83078199 Web.: www.hwa-hsing.com E-Mail: [email protected] Release Ver. 1.4 Page 4 of 6 Project No.: 220218KH03-1-1 Lab: Hwa-Hsing (Dongguan) Testing Co., Ltd. Address: No.101, Bld N1, Yuyuan 2Rd, Yuyuan Industrial Park, HuangJiang Town, Dongguan, China Tel: 0769-83078199 Web.: www.hwa-hsing.com E-Mail: [email protected] Release Ver. 1.4 Page 5 of 6 Project No.: 220218KH03-1-1 Lab: Hwa-Hsing (Dongguan) Testing Co., Ltd. Address: No.101, Bld N1, Yuyuan 2Rd, Yuyuan Industrial Park, HuangJiang Town, Dongguan, China Tel: 0769-83078199 Web.: www.hwa-hsing.com E-Mail: [email protected] Release Ver. 1.4 Page 6 of 6 Project No.: 220218KH03-1-1 BLE ANT

RF Exposure Info

Lab: Hwa-Hsing (Dongguan) Testing Co., Ltd. Address: No.101, Bld N1, Yuyuan 2Rd, Yuyuan Industrial Park, HuangJiang Town, Dongguan, China Tel: 0769-83078199 Web.: www.hwa-hsing.com E-Mail: [email protected] Release Ver. 1.4 Page 1 of 7 Test Report No.: 220218KH03-SE-US-01-02 RF Exposure Report FCC ID: 2AR2STAB7807RESW Applicant: MMD Hong Kong Holding Limited Address: Unit 1006, 10th Floor, C-Bons International Center, 108 Wai Yip Street, Kwun Tong, Kowloon, Hong Kong Manufacturer: MMD Hong Kong Holding Limited Address: Unit 1006, 10th Floor, C-Bons International Center, 108 Wai Yip Street, Kwun Tong, Kowloon, Hong Kong Product: Wireless subwoofer Brand: PHILIPS or Test Model(s): TAB7807 Series Model(s): See section 2.1 Test Date: Mar. 08, 2022~Mar. 28, 2022 Issued Date: Apr. 19, 2022 Issued By: Hwa-Hsing (Dongguan) Testing Co., Ltd. Address: No.101, Bld N1, Yuyuan 2Rd, Yuyuan Industrial Park, HuangJiang Town, Dongguan, China Test Firm Registration No.: 915896 Standards: 47 CFR FCC Part 15, Subpart C (Section 15.247) ANSI C63.10:2013 The above equipment has been tested by Hwa-Hsing (Dongguan) Testing Co., Ltd., and found compliance with the requirement of the above standards. The test record, data evaluation & Equipment Under Test (EUT) configurations represented herein are true and accurate accounts of the measurements of the sample’s EMC characteristics under the conditions specified in this report. Prepared by : Reviewed by : Myrna Chen/ Report Engineer Scott He/ Project Engineer Approved by : Harry Li/ Technical Director This report is for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you provided to us. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence, provided, however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Unless specific mention, the uncertainty of measurement has been explicitly taken into account to declare the compliance or non-compliance to the specification. The report must not be used by the client to claim product certification, approval, or endorsement by A2LA or any agency of the federal government.The report must not be used by the client to claim product certification, approval, or endorsement by TAF or any government agencies. Lab: Hwa-Hsing (Dongguan) Testing Co., Ltd. Address: No.101, Bld N1, Yuyuan 2Rd, Yuyuan Industrial Park, HuangJiang Town, Dongguan, China Tel: 0769-83078199 Web.: www.hwa-hsing.com E-Mail: [email protected] Release Ver. 1.4 Page 2 of 7 Test Report No.: 220218KH03-SE-US-01-02 Table of contents Release control record ............................................................................................................................ 3 1 General Information ...................................................................................................................... 4 1.1 General Description of EUT ....................................................................................................... 4 2 RF exposure limit .......................................................................................................................... 5 2.1 MPE calculation formula ............................................................................................................ 5 3 Calculation result of maximum conducted power ......................................................................... 6 Appendix – Information on the Testing Laboratories ................................................................................ 7 Lab: Hwa-Hsing (Dongguan) Testing Co., Ltd. Address: No.101, Bld N1, Yuyuan 2Rd, Yuyuan Industrial Park, HuangJiang Town, Dongguan, China Tel: 0769-83078199 Web.: www.hwa-hsing.com E-Mail: [email protected] Release Ver. 1.4 Page 3 of 7 Test Report No.: 220218KH03-SE-US-01-02 Release control record Issue No. Reason for change Date issued 220218KH03-SE-US-01-02 Original Release Apr. 19, 2022 Lab: Hwa-Hsing (Dongguan) Testing Co., Ltd. Address: No.101, Bld N1, Yuyuan 2Rd, Yuyuan Industrial Park, HuangJiang Town, Dongguan, China Tel: 0769-83078199 Web.: www.hwa-hsing.com E-Mail: [email protected] Release Ver. 1.4 Page 4 of 7 Test Report No.: 220218KH03-SE-US-01-02 1 General Information 1.1 General Description of EUT Product Wireless subwoofer Brand PHILIPS or Test Model(s) TAB7807 Series Model(s) TAB7807RE, TAB7807/10, TAB7807RE/10, TAB7807/37, TAB7807RE/37, TAB7807/98, TAB7807RE/98, TAB7807xx/yy(x=A-Z or blank, yy=00-99 or blank for country code) Status of EUT Engineering Prototype Power Supply Rating 100-240V~ 50/60Hz 45W; Modulation Type GFSK Transfer Rate 2Mbps Operating Frequency 2402 ~ 2480MHz Number of Channel 40 Output Power(Average) -9.27dBm Antenna Type PCB Antenna Antenna Gain 0.19dBi Maximum peak Gain Antenna Connector N/A Accessory Device N/A Cable Supplied AC Lines: 142cm Note: 1. Please refer to the EUT photo document (Reference No.: 220218KH03-1-1&-2) for detailed product photo. 2. The above EUT information is declared by manufacturer and for more detailed features description, please refer to the manufacturer's specifications or User's M…

Text truncated - open the document above for the full version.

Test Report

Lab: Hwa-Hsing (Dongguan) Testing Co., Ltd. Address: No.101, Bld N1, Yuyuan 2Rd, Yuyuan Industrial Park, HuangJiang Town, Dongguan, China Tel: 0769-83078199 Web.: www.hwa-hsing.com E-Mail: [email protected] Release Ver. 1.4 Page 1 of 46 Test Report No.: 220218KH03-RF-US-01-02 FCC Part 15, Subpart C Test Report FCC ID: 2AR2STAB7807RESW Applicant: MMD Hong Kong Holding Limited Address: Unit 1006, 10th Floor, C-Bons International Center, 108 Wai Yip Street, Kwun Tong, Kowloon, Hong Kong Manufacturer: MMD Hong Kong Holding Limited Address: Unit 1006, 10th Floor, C-Bons International Center, 108 Wai Yip Street, Kwun Tong, Kowloon, Hong Kong Product: Wireless subwoofer Brand: PHILIPS or Test Model(s): TAB7807 Series Model(s): See section 2.1 Test Date: Mar. 08, 2022~Mar. 28, 2022 Issued Date: Apr. 19, 2022 Issued By: Hwa-Hsing (Dongguan) Testing Co., Ltd. Address: No.101, Bld. N1, Yuyuan 2Rd, Yuyuan Industrial Park, HuangJiang Town, Dongguan, China Test Firm Registration No.: 915896 Standards: 47 CFR FCC Part 15, Subpart C (Section 15.247) ANSI C63.10:2013 The above equipment has been tested by Hwa-Hsing (Dongguan) Testing Co., Ltd., and found compliance with the requirement of the above standards. The test record, data evaluation & Equipment Under Test (EUT) configurations represented herein are true and accurate accounts of the measurements of the sample’s EMC characteristics under the conditions specified in this report. Prepared by : Reviewed by : Myrna Chen/ Report Engineer Scott He/ Project Engineer Approved by : Harry Li/ Technical Director This report is for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you provided to us. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence, provided, however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Unless specific mention, the uncertainty of measurement has been explicitly taken into the account to declare the compliance or non-compliance to the specification. The report must not be used by the client to claim product certification, approval, or endorsement by A2LA or any agency of the federal government. The report must not be used by the client to claim product certification, approval, or endorsement by TAF or any government agencies. Lab: Hwa-Hsing (Dongguan) Testing Co., Ltd. Address: No.101, Bld N1, Yuyuan 2Rd, Yuyuan Industrial Park, HuangJiang Town, Dongguan, China Tel: 0769-83078199 Web.: www.hwa-hsing.com E-Mail: [email protected] Release Ver. 1.4 Page 2 of 46 Test Report No.: 220218KH03-RF-US-01-02 Table of Contents Release Control Record .................................................................................................................................. 4 1. Summary of Test Results .......................................................................................................................... 5 1.1 Measurement Uncertainty ..................................................................................................................... 5 1.2 Modification Record .............................................................................................................................. 5 2. General Information ................................................................................................................................... 6 2.1 General Description of EUT .................................................................................................................. 6 2.2 Description of Test Channels ................................................................................................................ 7 2.3 Test Mode Applicability and Tested Channel Detail ............................................................................. 7 2.4 Description of Support Units ................................................................................................................. 9 2.5 Configuration of System under Test ..................................................................................................... 9 2.6 Duty Cycle of Test Signal ..................................................................................................................... 9 3. Test Types and Results ........................................................................................................................... 10 3.1 Radiated Emission and Band-edge Measurement ............................................................................. 10 3.1.1 Limits of radiated emission and band-edge measurement ...................................................... 10 3.1.2 Test Instruments ....................................................................................................................... 11 3.1.3 Test Procedures ....................................................................................................................... 12 3.1.4 Deviation from Test Standard ................................................................................................... 13 3.1.5 Test Setup ......................................................................…

Text truncated - open the document above for the full version.

Test Setup Photos

Lab: Hwa-Hsing (Dongguan) Testing Co., Ltd. Address: No.101, Bld N1, Yuyuan 2Rd, Yuyuan Industrial Park, HuangJiang Town, Dongguan, China Tel: 0769-83078199 Web.: www.hwa-hsing.com E-Mail: [email protected] Release Ver. 1.4 Page 1 of 3 Project No.: 220218KH03-1-3 Set-Up for Conducted Emission Test Frequency Range< 0.15MHz~30MHz > Lab: Hwa-Hsing (Dongguan) Testing Co., Ltd. Address: No.101, Bld N1, Yuyuan 2Rd, Yuyuan Industrial Park, HuangJiang Town, Dongguan, China Tel: 0769-83078199 Web.: www.hwa-hsing.com E-Mail: [email protected] Release Ver. 1.4 Page 2 of 3 Project No.: 220218KH03-1-3 Set-Up for Radiated Emission Test Frequency Range< 30MHz~1GHz > Lab: Hwa-Hsing (Dongguan) Testing Co., Ltd. Address: No.101, Bld N1, Yuyuan 2Rd, Yuyuan Industrial Park, HuangJiang Town, Dongguan, China Tel: 0769-83078199 Web.: www.hwa-hsing.com E-Mail: [email protected] Release Ver. 1.4 Page 3 of 3 Project No.: 220218KH03-1-3 Frequency Range< Above 1GHz >

Contact Information

Applicant

Tomas Guan(Safety & Approbation Manager)
[email protected]86-755-36358341Fax: 86-755-26634642

Test Firm

Hwa-Hsing (Dongguan) Testing Co., Ltd.David Chen
[email protected]0769-83078199

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz3.47 mW
Confidentiality
Long Term

Other Applications from MMD Hong Kong Holding Limited

2AR2STAA6219

On-ear solar-powered headphones

Sep 26, 2024

Equipment Class

DTS - Digital Transmission System
2AR2STAA6709

True wireless sports headphones

Aug 20, 2024

Equipment Class

DTS - Digital Transmission System
2AR2STAX5509

Party Speaker

Aug 04, 2024

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
2AR2STAS2508M

Wireless Speaker

Jul 21, 2024

Equipment Class

DTS - Digital Transmission System
2AR2STAS2508

Wireless Speaker

Jun 26, 2024

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter