Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Quick Star t Guide Gett ing St ar ted: Thank you fo r choosing t he 4G MiFi . Note: This guide pro vi de s the basic opera ti ons of the Mi Fi. For confi gu rati on l og into the web gr ap hical user interface a nd click the hel p i con o n t he top ri ght corner. Gett ing to Know Your 4G MiFi 1.Screen 2.Power button 3.WPS button 4.Reset button 5.Typ e-CUSB Basic Info on Screen Display 6.Battery Power 7.Si gn al S trengt h o f Wi-F i 8.Number of Wi-F i Users 9.Message Sign 10 . Number of messages 11 . Network Type 12 . Si gn al S trength ofCellular 13 . Name of the Network Service Provide r 14 . Time Insta ll SIM Card and Battery 1.Power off the MiFi . 2.Remove the back cover and battery. 3.In se rt the SIMcard into card slot in th e correct po si ti on . 4.In stall battery and back cover. Note: Do not remove the SIM card when it is in use, Doing so will affect the performance of your device and data stored on the SIM card may be lost. Sett ing Up a Wi-Fi Connect ion Step1:Power on t he MiFi. Step2:Set up Wi-Fi connection o r wired connection. Ste p3:Conn ect to internet. I. Turning on MiFi Press βPower butto nβ and hol d for a while till th e screen i s lit, and Wi-F i is on. II. Setting up Wi-F i connect ion or wired connection 1.Set up Wi-F i conn ection or wired connection as blow. 2.Make sure t he 4G Mi Fi βs Wi-F i functi on i s on. 3.Select Start>ControlPanel>Network Conne cti ons> Wire less Network Conn ection 4.Click βConnect toβ to show a list of availabl e Wi-Fi n etworks . 5.Select th e wireless network connection wi th th e 4G Mi Fi 's SSID and clickβConnectβ. If th e sec uri ty mechanism is appli ed, you need to enter the correct network ke y. The SSID an d network key a re printed o n t he Mi Fi βs labe l. Note: How to c hang e the SSID & Password 1.Lo g i n to http://192.168.1. 1 or http :/ /192.168 .0.1 (refer to t he devi ce lab el) an d ente r t he management pag e. 2.Select Wire less>WLAN basic settings, then yo u wi ll see βSSIDβ and β Wi-F i Password β, Ensure you delete the old name a nd pa ssword a nd enter the new name and new pa ssword as your required. 3.Click βOKβ button, t hen l og out. 4.Wait for computer o r l aptop screen to disp lay th e modifi ed Wi-F i i con. Indi cates t hat t he SSID & pa ssword of the wi reless network has been modifi ed successfully. III. Connect ing to th e inte rnet If the Wi-F i function i s turned on, your device sh ould conn ect to the Interne t auto mati ca lly . IV. Logging into th e Dev ice Management websi te 1. Make sure t he end-user device is connected to theMi Fi . 2. Open t he browser, ente r http ://192.1 68.1.1or http :/ /192.168 .0.1 (refer to t he devi ce label)in th e address box. 3.Ente r t he user nameand password, a nd click βl oginβ. The administrator has t he ri gh t t o ch ec k and modi fy confi gu ration p ermission . Note: The default usernameand password are admin. Charging your MiFi 1s t method: Charging by power adapte r 1.Use compati bl e p ower adapter (5v, 2A). 2.Power adap ter is a selective accessory. 2ndmethod:Charging by connecti ng to computer or laptop. Please use t he p roper cable to con nect th e MiFi to the computeror l ap top. Note:If the MiFihas nβt been used for a long ti me, pl ea se charge the battery be fore usi ng. Restore Factory Setti ngs If you are un certai n o f which Wi-F i settings you have confi gured or changed, you can restore the fa ctory defaults that come with the MiFito reconfi gure the device Wi-F i setting. 1.Lo g i nto Device Manage ment Web site to restore to fa ctory de fa ult setti ngs. 2.Press and hol d βResetβ butt on fo r 8se conds, an d the MiFi w ill b e acti vated again and restore d to factory settings. Note: Reset button will d el ete all th e d eviceβs user-de fi ned Wi-Fi sett ings and restore Admi n setting and Wi-F i Setting to factory defa ults. Trouble Shooting: If you are havi ng troubl e with t he MiFi , h er e are a fe w things you can d o to get it to fu ncti on properly: 1. Log i nto t he de vi ce management website and cli ck the hel p i con o n t he top ri gh t corner for an swers to frequentl y asked questi on s. 2. If the MiFi is not responsi ve , restart the device. 3. Restore fa ctory setti ngs. 4.Contact your service pro vi der. Note:All figures above are for reference o nly. Safe ty info rmation: 1. Cauti on: Risk of expl osion i f b attery is repl aced wi th a n i ncorrect or un ap proved type. Use d ba tteries must be disp osed according t o the manufact urer's i nstructi ons. 2. The Mi Fi product shall only be connected usi ng a USB interface of version U SB2.0. 3. Adapter shall be i nst alled near the equipment an d shall be easily accessible. 4. The maximum op erating temperature o f th e Mi Fi is 55 . 5. The plug considered as disconn ect de vi ce of ad apter. 6. The d evice complies with RF specifi ca tions when t he device i s use d at 20 cm away from th e bo dy. 7. This equipment i s i n compliance with t he essenti al requ irements and other relevant provi si on s of directive 199 9/5/EC. FCC Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: -- Reorient or relocate the receiving antenna. -- Increase the separation between the equipment and receiver. -- Connect the equipment into an outlet on a ciβ¦
Text truncated - open the document above for the full version.
Shanghai Notion Information Technology CO. LTD Section 2.911(d)(5)(i) Certification β Equipment Type Company name: Shanghai Notion Information Technology CO. LTD Address: Room 408,Building 2, Lane 666,Zhangheng Rd, Pudong New Area, Shanghai, China Product Name: LTE Wireless Router/LTE Mobile Wifi/LTE MiFi/4G MIFI FCC ID: 2AR45-M281T Model(s): M281T, M27, M271, M271s, M271T, M271Ts, M272, M272s, M272T, M272Ts, M28, M281, M281s, M281Ts, M29, M291, M291T, M291s, M291Ts, L28l, L27I, M281e, M271e, M291e, M6 2.911(d)(5)(i) Equipment Type We, [Shanghai Notion Information Technology CO. LTD] certify that the equipment for which authorization is sought through certification is not: ο· Prohibited from receiving an equipment authorization pursuant to Β§ 2.903; of the FCC rules. ο· Identified as an equipment type in the βCovered Listβ NOTE 1 Yours sincerely, Signature: Name: Peng Sun Date: 2024-06-12 Title and Company name: Project Manager and Shanghai Notion Information Technology CO. LTD NOTE 1 βCovered Listβ; is the List of Equipment and Services Covered By Section 2 of The Secure Networks Act, available at https://www.fcc.gov/supplychain/coveredlist References; 1) 986446 D01 Covered Equipment v01 https://apps.fcc.gov/oetcf/kdb/forms/FTSSearchResultPage.cfm?switch=P&id=325672 2) Federal Register document 2022-28263 published on 02/06/23 https://www.federalregister.gov/documents/2023/02/06/2022-28263/protecting-against-national-security-threats-to-the-com munications-supply-chain-through-the
Shanghai Notion Information Technology CO. LTD * the applicant must designate a contact located in the United States for purposes of acting as the applicantβs agent for service of process, regardless of whether the applicant is a domestic or foreign entity. An applicant located in the United States may designate itself as the agent for service of process. U.S. Agent Designation for Service of Process - Certification Attestation Letter Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA ATTN.: Reviewing Engineer FCC ID: 2AR45-M281T FRN of applicant: 0028085231 Per section 2.911(d)(7) of the FCC rules, Shanghai Notion Information Technology CO. LTD certifies that the equipment for which authorization is sought is designated to the following U.S. agent* for service of process: Company Name: Baihetian Innovative Solutions FCC Registration Number (FRN): 0033401605 Physical U.S. Company Address: 6837 Chase Rd, Dearborn, MI 48126, USA Contact Person: Kenneth Young Agent Email Address: [email protected] The above contact person accepts the obligation for service of process. The applicant accepts to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any Commission-related proceeding involving the equipment. Applicant Signed: Signed: Printed name: Peng Sun Title: Project Manager Company Name: Shanghai Notion Information Technology CO. LTD Date: 6/12/2024 Agent Signed: Signed: Printed name: Kenneth Young Title: Manager Company Name: Baihetian Innovative Solutions Date: 6/12/2024
Differences Declaration To whom concern, We company Shanghai Notion Information Technology CO. LTD hereby declares: The product models M281T, M27, M271, M271s, M271T, M271Ts, M272, M272s, M272T, M272Ts, M28, M281, M281s, M281Ts, M29, M291, M291T, M291s, M291Ts, L28l, L27I, M281e, M271e, M291e, M6 are identical in the same PCB layout, interior structure and electrical circuits, The differences are appearance color and model name for commercial purpose. Authorized signature: Date: 2024-06-12
Shanghai Notion Information Technology CO. LTD Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 USA Date: 2024-06-12 FCC ID: 2AR45-M281T To Whom It May Concern, Pursuant to the provisions of the Commissionβs rules Title 47 Sections Β§0.457 and Β§0.459, we are requesting the Commission to withhold the following attachment(s) as confidential documents from public disclosure indefinitely. These documents contain detailed system and equipment descriptions and are considered as proprietary information in operation of the equipment. The public disclosure of these documents might be harmful to our company and would give competitors an unfair advantage in the market. Schematic Diagram Block Diagram Operational Description Part List Tune-up Procedure It is our understanding that all measurement test reports, FCC ID label format and correspondence during the certification review process cannot be granted as confidential documents and this information will be available for public review once the grant of equipment authorization is issued. Sincerely, Signature: Name: Peng Sun Title: Project Manager
Page 1 of 4 Page 2 of 4 Page 3 of 4 Page 4 of 4
LTE MiFi Model: M281T IMEI:8602310517614823 S/N:M281T866S220727000001 MAC ID : 5C:F2:86:26:DB:1D Made in China SSID: L28I_XXXXWiFi Key:xxxxxxxx User Name: adminPassword: adminhttps://192.168.1.1 Rating: 5V 1A Shanghai Notion Information Technology Co. Ltd Room 408, Building 2,Grand Global R & D Center, Lane 666, Zhangheng Road, Pudong New Area,Shanghai Importer: XXXXXX Exporter: XXXXXX FCC ID: 2AR45-M281T
Label location:
Page 1 of 6 Page 2 of 6 Page 3 of 6 Page 4 of 6 Page 5 of 6 Page 6 of 6
Totalor partialreproductionof this documentwithoutpermissionof the Laboratoryis not allowed.Page 1 of 73 BTF TestingLab (Shenzhen)Co., Ltd. F101,201 and 301, Building1, Block2, TantouIndustrialPark,TantouCommunity,SonggangStreet,Bao'anDistrict,Shenzhen,China SAR Test Report For ApplicantName:ShanghaiNotionInformationTechnologyCO. LTD Address: Room408, Building2, Lane666, ZhanghengRd, PudongNew Area,Shanghai,China EUT Name:LTE WirelessRouter/LTEMobileWifi/LTEMiFi/4GMIFI ModelNumber:M281T SeriesModelNumber: M27,M271,M271s,M271T,M271Ts,M272,M272s,M272T, M272Ts,M28,M281,M281s,M281Ts,M29,M291,M291T, M291s,M291Ts,L28l,L27I,M281e,M271e,M291e,M6 IssuedBy CompanyName:BTF TestingLab (Shenzhen)Co., Ltd. Address: F101,201 and 301, Building1, Block2, TantouIndustrialPark, TantouCommunity,SonggangStreet,Bao'anDistrict,Shenzhen, China ReportNumber:BTF240605R0 05 01 Test Standards: FCC 47 CFR Β§2.1093IEC/IEEE62209-1528:2020 IEEEC95.1-2019KDB447498D04KDB865664D01 KDB865664D02 KDB941225D01KDB941225D05 KDB248227D01KDB941225D06KDB648474D04 KDB690783D01 FCC ID:2AR45-M281T Test Conclusion:Pass Test Date:202 4-06-05to 2024-06-12 Dateof Issue:202 4-06-13 PreparedBy: AmendaZhong/ ProjectEngineer Date:2024-06-13 ApprovedBy: Ryan.CJ/ EMCManager Date:2024-06-13 Note: All the test resultsin this reportonly relatedto the testingsamples.Whichcan be duplicatedcompletelyfor the legal use with approvalof applicant;it shall not be reproducedexceptin full withoutthe writtenapprovalof BTF TestingLab (Shenzhen)Co., Ltd., All the objectionsshouldbe raisedwithin thirty days from the date of issue.To validatethe report,you can contactus. Test ReportNumber:BTF2 40 605R0 0501 Totalor partialreproductionof this documentwithoutpermissionof the Laboratoryis not allowed.Page 2 of 73 BTF TestingLab (Shenzhen)Co., Ltd. F101,201 and 301, Building1, Block2, TantouIndustrialPark,TantouCommunity,SonggangStreet,Bao'anDistrict,Shenzhen,China RevisionHistory VersionIssueDateRevisionsContent R_V02024-06-13Original Note:Once the revisionhas been made,then previousversionsreportsare invalid. Test ReportNumber:BTF2 40 605R0 0501 Totalor partialreproductionof this documentwithoutpermissionof the Laboratoryis not allowed.Page 3 of 73 BTF TestingLab (Shenzhen)Co., Ltd. F101,201 and 301, Building1, Block2, TantouIndustrialPark,TantouCommunity,SonggangStreet,Bao'anDistrict,Shenzhen,China Tabl e of Contents 1. Introduction...............................................................................................................................................................................4 1.1 Identificationof TestingLaboratory.................................................................................................................................4 1.2 Identificationof the ResponsibleTestingLocation..........................................................................................................4 1.3 LaboratoryCondition.......................................................................................................................................................4 1.4 Announcement................................................................................................................................................................4 2. ProductInformation..................................................................................................................................................................5 2.1 ApplicationInformation....................................................................................................................................................5 2.2 ManufacturerInformation................................................................................................................................................5 2.3 FactoryInformation.........................................................................................................................................................5 2.4 GeneralDescriptionof EquipmentunderTest (EUT).....................................................................................................5 2.5 EquipmentunderTest AncillaryEquipment....................................................................................................................5 2.6 TechnicalInformation......................................................................................................................................................5 3. Summaryof Test Results.........................................................................................................................................................6 3.1 Test Standards................................................................................................................................................................6 3.2 DeviceCategoryand SARLimit ......................................................................................................................................7 3.3 Test ResultSummary......................................................................................................................................................7 3.4 Test Uncertainty..............................................................................................................................................................8 4. MeasurementSystem.............................................................................................................................................................10 4.1 SpecificAbsorptionRate(SAR)Definition....................................................................................................................10 4.2 MVGSARSystem.........................................................................................................................................................10 5. SystemVerification..................................................................................................................................β¦
Text truncated - open the document above for the full version.
Report No.:GTS2024040098F01 Global United Technology Services Co., Ltd. No. 123- 128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 1 of 56 AppendixA: Effective (Isotropic) Radiated Power Output Data Test Result(WCDMA) Band Channel Power(dBm) Gain (dBi) EIRP/ERP (dBm) Limit(dBm) Verdict Band2 9262 24.00 2.67 26.67 33.01 PASS Band2 9400 23.70 2.67 26.37 33.01 PASS Band2 9538 24.33 2.67 27.00 33.01 PASS Band4 1312 25.33 2.67 28.00 30.00 PASS Band4 1413 24.55 2.67 27.22 30.00 PASS Band4 1513 25.64 2.67 28.31 30.00 PASS Band5 4132 27.84 1.39 27.08 38.45 PASS Band5 4182 28.14 1.39 27.38 38.45 PASS Band5 4233 28.00 1.39 27.24 38.45 PASS Test Result(HSDPA) Band Channel SubTest Power(dBm) Gain (dBi) EIRP/ERP (dBm) Limit(dBm) Verdict Band2 9262 1 24.26 2.67 26.93 33.01 PASS Band2 9262 2 23.68 2.67 26.35 33.01 PASS Band2 9262 3 23.16 2.67 25.83 33.01 PASS Band2 9262 4 23.13 2.67 25.80 33.01 PASS Band2 9400 1 24.16 2.67 26.83 33.01 PASS Band2 9400 2 23.60 2.67 26.27 33.01 PASS Band2 9400 3 23.20 2.67 25.87 33.01 PASS Band2 9400 4 23.12 2.67 25.79 33.01 PASS Band2 9538 1 24.27 2.67 26.94 33.01 PASS Band2 9538 2 23.80 2.67 26.47 33.01 PASS Band2 9538 3 23.41 2.67 26.08 33.01 PASS Band2 9538 4 23.41 2.67 26.08 33.01 PASS Band4 1312 1 25.86 2.67 28.53 30.00 PASS Band4 1312 2 25.47 2.67 28.14 30.00 PASS Band4 1312 3 25.27 2.67 27.94 30.00 PASS Band4 1312 4 25.21 2.67 27.88 30.00 PASS Band4 1413 1 26.01 2.67 28.68 30.00 PASS Band4 1413 2 25.13 2.67 27.80 30.00 PASS Band4 1413 3 24.47 2.67 27.14 30.00 PASS Band4 1413 4 24.41 2.67 27.08 30.00 PASS Band4 1513 1 26.25 2.67 28.92 30.00 PASS Band4 1513 2 25.91 2.67 28.58 30.00 PASS Band4 1513 3 25.56 2.67 28.23 30.00 PASS Report No.:GTS2024040098F01 Global United Technology Services Co., Ltd. No. 123- 128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 2 of 56 Band4 1513 4 25.55 2.67 28.22 30.00 PASS Band5 4132 1 27.74 1.39 26.98 38.5 PASS Band5 4132 2 26.85 1.39 26.09 38.5 PASS Band5 4132 3 26.32 1.39 25.56 38.5 PASS Band5 4132 4 26.28 1.39 25.52 38.5 PASS Band5 4182 1 28.01 1.39 27.25 38.5 PASS Band5 4182 2 27.22 1.39 26.46 38.5 PASS Band5 4182 3 26.82 1.39 26.06 38.5 PASS Band5 4182 4 26.79 1.39 26.03 38.5 PASS Band5 4233 1 27.92 1.39 27.16 38.5 PASS Band5 4233 2 27.12 1.39 26.36 38.5 PASS Band5 4233 3 26.62 1.39 25.86 38.5 PASS Band5 4233 4 26.60 1.39 25.84 38.5 PASS Test Result(HSUPA) Band Channel SubTest Power(dBm) Gain (dBi) EIRP/ERP (dBm) Limit(dBm) Verdict Band2 9262 1 25.64 2.67 28.31 33.01 PASS Band2 9262 2 24.19 2.67 26.86 33.01 PASS Band2 9262 3 25.44 2.67 28.11 33.01 PASS Band2 9262 4 24.92 2.67 27.59 33.01 PASS Band2 9262 5 26.82 2.67 29.49 33.01 PASS Band2 9400 1 25.87 2.67 28.54 33.01 PASS Band2 9400 2 24.56 2.67 27.23 33.01 PASS Band2 9400 3 26.15 2.67 28.82 33.01 PASS Band2 9400 4 25.40 2.67 28.07 33.01 PASS Band2 9400 5 27.47 2.67 30.14 33.01 PASS Band2 9538 1 25.93 2.67 28.60 33.01 PASS Band2 9538 2 24.90 2.67 27.57 33.01 PASS Band2 9538 3 25.80 2.67 28.47 33.01 PASS Band2 9538 4 25.33 2.67 28.00 33.01 PASS Band2 9538 5 26.07 2.67 28.74 33.01 PASS Band4 1312 1 23.64 2.67 26.31 30.00 PASS Band4 1312 2 21.73 2.67 24.40 30.00 PASS Band4 1312 3 22.15 2.67 24.82 30.00 PASS Band4 1312 4 21.52 2.67 24.19 30.00 PASS Band4 1312 5 24.38 2.67 27.05 30.00 PASS Band4 1413 1 23.27 2.67 25.94 30.00 PASS Band4 1413 2 21.46 2.67 24.13 30.00 PASS Band4 1413 3 22.31 2.67 24.98 30.00 PASS Band4 1413 4 21.57 2.67 24.24 30.00 PASS Band4 1413 5 23.74 2.67 26.41 30.00 PASS Band4 1513 1 23.94 2.67 26.61 30.00 PASS Report No.:GTS2024040098F01 Global United Technology Services Co., Ltd. No. 123- 128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 3 of 56 Band4 1513 2 21.97 2.67 24.64 30.00 PASS Band4 1513 3 22.86 2.67 25.53 30.00 PASS Band4 1513 4 22.14 2.67 24.81 30.00 PASS Band4 1513 5 24.61 2.67 27.28 30.00 PASS Band5 4132 1 26.82 1.39 26.06 38.5 PASS Band5 4132 2 25.07 1.39 24.31 38.5 PASS Band5 4132 3 25.83 1.39 25.07 38.5 PASS Band5 4132 4 25.12 1.39 24.36 38.5 PASS Band5 4132 5 27.46 1.39 26.70 38.5 PASS Band5 4182 1 27.19 1.39 26.43 38.5 PASS Band5 4182 2 25.73 1.39 24.97 38.5 PASS Band5 4182 3 26.24 1.39 25.48 38.5 PASS Band5 4182 4 25.93 1.39 25.17 38.5 PASS Band5 4182 5 27.73 1.39 26.97 38.5 PASS Band5 4233 1 27.03 1.39 26.27 38.5 PASS Band5 4233 2 25.72 1.39 24.96 38.5 PASS Band5 4233 3 26.52 1.39 25.76 38.5 PASS Band5 4233 4 25.83 1.39 25.07 38.5 PASS Band5 4233 5 27.61 1.39 26.85 38.5 PASS Report No.:GTS2024040098F01 Global United Technology Services Co., Ltd. No. 123- 128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 4 of 56 AppendixB:Peak-to-Average Ratio Test Result(WCDMA) Band Channel Peak-to-Average Ratio(dB) Limit(dB) Verdict Band2 9262 2.53 13 PASS Band2 9400 2.8 13 PASS Band2 9538 2.39 13 PASS Band4 1312 2.15 13 PASS Band4 1413 1.78 13 PASS Band4 1513 1.98 13 PASS Band5 4132 1.86 13 PASS Band5 4182 2.01 13 PASS Band5 4233 1.99 13 PASS Test Result(HSDPA) Band Channel SubTest Peak-to-Average Ratio(dB) Limit(dB) Verdict Band2 9262 1 2.62 13 PASS Band2 9400 1 2.88 13 PASS Band2 9538 1 2.43 13 PASS Band4 1312 1 2.13 13 PASS Band4 1413 1 1.81 13 PASS Band4 1513 1 1.99 13 PASS Band5 4132 1 1.86 13 PASS Band5 4182 1 2.01 13 PASS Band5 4233 1 2.02 13 PASS Test Result(HSUPA) Band Channel SubTest Peak-to-Average Ratio(dB) Limit(dB) Verdict Band2 9262 1 3.14 13 PASS Band2 9400 1 3.32 13 PASS Band2 9538 1 2.94 13 PASS Band4 1312 1 3.07 13 PASS Band4 1413 1 3 13 PASS Banβ¦
Text truncated - open the document above for the full version.
Report No.:GTS2024040098F02 Global United Technology Services Co., Ltd. No. 123- 128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 1 of 68 AppendixA: Effective (Isotropic) Radiated Power Output Data Test Result Band Bandwidth Modulation Channel RB Configuration Result(dBm) Gain (dBi) EIRP (dBm) Limit(dBm) Verdict Band2 1.4MHz QPSK 18607 1RB#0 23.20 2.67 25.87 33.01 PASS Band2 1.4MHz QPSK 18607 1RB#2 23.20 2.67 25.87 33.01 PASS Band2 1.4MHz QPSK 18607 1RB#5 23.23 2.67 25.90 33.01 PASS Band2 1.4MHz QPSK 18607 3RB#0 23.22 2.67 25.89 33.01 PASS Band2 1.4MHz QPSK 18607 3RB#1 23.22 2.67 25.89 33.01 PASS Band2 1.4MHz QPSK 18607 3RB#3 23.22 2.67 25.89 33.01 PASS Band2 1.4MHz QPSK 18607 6RB#0 22.30 2.67 24.97 33.01 PASS Band2 1.4MHz QPSK 18900 1RB#0 23.28 2.67 25.95 33.01 PASS Band2 1.4MHz QPSK 18900 1RB#2 23.27 2.67 25.94 33.01 PASS Band2 1.4MHz QPSK 18900 1RB#5 23.30 2.67 25.97 33.01 PASS Band2 1.4MHz QPSK 18900 3RB#0 23.24 2.67 25.91 33.01 PASS Band2 1.4MHz QPSK 18900 3RB#1 23.33 2.67 26.00 33.01 PASS Band2 1.4MHz QPSK 18900 3RB#3 23.31 2.67 25.98 33.01 PASS Band2 1.4MHz QPSK 18900 6RB#0 22.39 2.67 25.06 33.01 PASS Band2 1.4MHz QPSK 19193 1RB#0 23.43 2.67 26.10 33.01 PASS Band2 1.4MHz QPSK 19193 1RB#2 23.04 2.67 25.71 33.01 PASS Band2 1.4MHz QPSK 19193 1RB#5 22.59 2.67 25.26 33.01 PASS Band2 1.4MHz QPSK 19193 3RB#0 22.92 2.67 25.59 33.01 PASS Band2 1.4MHz QPSK 19193 3RB#1 22.79 2.67 25.46 33.01 PASS Band2 1.4MHz QPSK 19193 3RB#3 22.51 2.67 25.18 33.01 PASS Band2 1.4MHz QPSK 19193 6RB#0 22.48 2.67 25.15 33.01 PASS Band2 1.4MHz 16QAM 18607 1RB#0 22.44 2.67 25.11 33.01 PASS Band2 1.4MHz 16QAM 18607 1RB#2 22.45 2.67 25.12 33.01 PASS Band2 1.4MHz 16QAM 18607 1RB#5 22.45 2.67 25.12 33.01 PASS Band2 1.4MHz 16QAM 18607 3RB#0 22.11 2.67 24.78 33.01 PASS Band2 1.4MHz 16QAM 18607 3RB#1 22.11 2.67 24.78 33.01 PASS Band2 1.4MHz 16QAM 18607 3RB#3 22.13 2.67 24.80 33.01 PASS Band2 1.4MHz 16QAM 18607 6RB#0 21.22 2.67 23.89 33.01 PASS Band2 1.4MHz 16QAM 18900 1RB#0 22.43 2.67 25.10 33.01 PASS Band2 1.4MHz 16QAM 18900 1RB#2 22.43 2.67 25.10 33.01 PASS Band2 1.4MHz 16QAM 18900 1RB#5 22.49 2.67 25.16 33.01 PASS Band2 1.4MHz 16QAM 18900 3RB#0 22.08 2.67 24.75 33.01 PASS Band2 1.4MHz 16QAM 18900 3RB#1 22.08 2.67 24.75 33.01 PASS Band2 1.4MHz 16QAM 18900 3RB#3 22.12 2.67 24.79 33.01 PASS Band2 1.4MHz 16QAM 18900 6RB#0 21.30 2.67 23.97 33.01 PASS Band2 1.4MHz 16QAM 19193 1RB#0 22.55 2.67 25.22 33.01 PASS Band2 1.4MHz 16QAM 19193 1RB#2 22.33 2.67 25.00 33.01 PASS Band2 1.4MHz 16QAM 19193 1RB#5 22.41 2.67 25.08 33.01 PASS Report No.:GTS2024040098F02 Global United Technology Services Co., Ltd. No. 123- 128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 2 of 68 Band2 1.4MHz 16QAM 19193 3RB#0 22.15 2.67 24.82 33.01 PASS Band2 1.4MHz 16QAM 19193 3RB#1 21.92 2.67 24.59 33.01 PASS Band2 1.4MHz 16QAM 19193 3RB#3 22.10 2.67 24.77 33.01 PASS Band2 1.4MHz 16QAM 19193 6RB#0 21.46 2.67 24.13 33.01 PASS Band2 3MHz QPSK 18615 1RB#0 23.09 2.67 25.76 33.01 PASS Band2 3MHz QPSK 18615 1RB#8 23.07 2.67 25.74 33.01 PASS Band2 3MHz QPSK 18615 1RB#14 23.09 2.67 25.76 33.01 PASS Band2 3MHz QPSK 18615 8RB#0 22.14 2.67 24.81 33.01 PASS Band2 3MHz QPSK 18615 8RB#4 22.13 2.67 24.80 33.01 PASS Band2 3MHz QPSK 18615 8RB#7 22.11 2.67 24.78 33.01 PASS Band2 3MHz QPSK 18615 15RB#0 22.15 2.67 24.82 33.01 PASS Band2 3MHz QPSK 18900 1RB#0 23.17 2.67 25.84 33.01 PASS Band2 3MHz QPSK 18900 1RB#8 23.11 2.67 25.78 33.01 PASS Band2 3MHz QPSK 18900 1RB#14 23.14 2.67 25.81 33.01 PASS Band2 3MHz QPSK 18900 8RB#0 22.23 2.67 24.90 33.01 PASS Band2 3MHz QPSK 18900 8RB#4 22.21 2.67 24.88 33.01 PASS Band2 3MHz QPSK 18900 8RB#7 22.21 2.67 24.88 33.01 PASS Band2 3MHz QPSK 18900 15RB#0 22.23 2.67 24.90 33.01 PASS Band2 3MHz QPSK 19185 1RB#0 23.43 2.67 26.10 33.01 PASS Band2 3MHz QPSK 19185 1RB#8 23.39 2.67 26.06 33.01 PASS Band2 3MHz QPSK 19185 1RB#14 23.37 2.67 26.04 33.01 PASS Band2 3MHz QPSK 19185 8RB#0 22.47 2.67 25.14 33.01 PASS Band2 3MHz QPSK 19185 8RB#4 22.45 2.67 25.12 33.01 PASS Band2 3MHz QPSK 19185 8RB#7 22.43 2.67 25.10 33.01 PASS Band2 3MHz QPSK 19185 15RB#0 22.44 2.67 25.11 33.01 PASS Band2 3MHz 16QAM 18615 1RB#0 22.25 2.67 24.92 33.01 PASS Band2 3MHz 16QAM 18615 1RB#8 22.23 2.67 24.90 33.01 PASS Band2 3MHz 16QAM 18615 1RB#14 22.24 2.67 24.91 33.01 PASS Band2 3MHz 16QAM 18615 8RB#0 21.24 2.67 23.91 33.01 PASS Band2 3MHz 16QAM 18615 8RB#4 21.24 2.67 23.91 33.01 PASS Band2 3MHz 16QAM 18615 8RB#7 21.23 2.67 23.90 33.01 PASS Band2 3MHz 16QAM 18615 15RB#0 21.18 2.67 23.85 33.01 PASS Band2 3MHz 16QAM 18900 1RB#0 22.38 2.67 25.05 33.01 PASS Band2 3MHz 16QAM 18900 1RB#8 22.31 2.67 24.98 33.01 PASS Band2 3MHz 16QAM 18900 1RB#14 22.35 2.67 25.02 33.01 PASS Band2 3MHz 16QAM 18900 8RB#0 21.35 2.67 24.02 33.01 PASS Band2 3MHz 16QAM 18900 8RB#4 21.31 2.67 23.98 33.01 PASS Band2 3MHz 16QAM 18900 8RB#7 21.30 2.67 23.97 33.01 PASS Band2 3MHz 16QAM 18900 15RB#0 21.22 2.67 23.89 33.01 PASS Band2 3MHz 16QAM 19185 1RB#0 22.62 2.67 25.29 33.01 PASS Band2 3MHz 16QAM 19185 1RB#8 22.55 2.67 25.22 33.01 PASS Band2 3MHz 16QAM 19185 1RB#14 22.50 2.67 25.17 33.01 PASS Band2 3MHz 16QAM 19185 8RB#0 21.62 2.67 24.29 33.01 PASS Band2 3MHz 16QAM 19185 8RB#4 21.56 2.67 24.23 33.01 PASS Report No.:GTS2024040098F02 Global United Technology Services Co., Ltd. No. 123- 128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 3 of 68 Band2 3MHz 16QAM 19185 8RB#7 21.55 2.67 24.22 33.01 PASS Band2 3MHz 16QAM 19185 15RB#0 21.50 2.67 24.17 33.01 PASS Band2 5MHz QPSK 18625 1RB#0 23.07 2.67 25.74 33.01 PASS Band2 5MHz QPSK 18625 1RB#12 23.03 2.67 25.70 33.01 PASSβ¦
Text truncated - open the document above for the full version.
Report No.:GTS2024040098F02 Global United Technology Services Co., Ltd. No. 123- 128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 19 of 68 Band2-20MHz-QPSK-18700-1RB#0-PASS Band2-20MHz-QPSK-18700-100RB#0-PASS Band2-20MHz-QPSK-18900-1RB#0-PASS Band2-20MHz-QPSK-18900-100RB#0-PASS Band2-20MHz-QPSK-19100-1RB#0-PASS Band2-20MHz-QPSK-19100-100RB#0-PASS Report No.:GTS2024040098F02 Global United Technology Services Co., Ltd. No. 123- 128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zβ¦
Text truncated - open the document above for the full version.
| # | Rule Parts | Frequency Range | Power Output | Emission | Tolerance |
|---|---|---|---|---|---|
| 24 | 27 | 2.54 GHz - 2.65 GHz | 342.00 mW | 18M0W7D | 2.5 ppm |

LTE MiFi
Equipment Class
DTS - Digital Transmission System
CPE
Equipment Class
DTS - Digital Transmission System