
Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
IC Caution: Radio Standards Specification RSS-Gen, issue 5 - English: This device contains licence-exempt transmitter(s)/receiver(s) that comply with Innovation, Science and Economic Development Canada’s licence-exempt RSS(s). Operation is subject to the following two conditions: This device may not cause interference. This device must accept any interference, including interference that may cause undesired operation of the device. RF exposure statement: The equipment complies with IC Radiation exposure limit set forth for uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator and your body. - French: Cet appareil contient des émetteurs / récepteurs exemptés de licence conformes aux RSS (RSS) d'Innovation, Sciences et Développement économique Canada. Le fonctionnement est soumis aux deux conditions suivantes: Cet appareil ne doit pas causer d'interférences. Cet appareil doit accepter toutes les interférences, y compris celles susceptibles de provoquer un fonctionnement indésirable de l'appareil. Déclaration d'exposition RF: L'équipement est conforme à la limite d'exposition aux radiations de la IC établie pour un environnement non contrôlé. Cet équipement doit être installé et utilisé avec une distance minimale de 20 cm entre le radiateur et votre corps.
1 - Page 1 of 4 - Report No.: MTi20102216-1E1-1 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: [email protected] Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’ an District, Shenzhen, Guangdong, China. APPENDIX 1: EUT PHOTO Photo 1 (For model Core300S) Photo 2 1 - Page 2 of 4 - Report No.: MTi20102216-1E1-1 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: [email protected] Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’ an District, Shenzhen, Guangdong, China. Photo 3 Photo 4 1 - Page 3 of 4 - Report No.: MTi20102216-1E1-1 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: [email protected] Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’ an District, Shenzhen, Guangdong, China. Photo 5 Photo 6 1 - Page 4 of 4 - Report No.: MTi20102216-1E1-1 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: [email protected] Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’ an District, Shenzhen, Guangdong, China. Photo 7 ----END OF REPORT----
1 - Page 1 of 4 - Report No.: MTi20102216-1E1-1 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: [email protected] Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’ an District, Shenzhen, Guangdong, China. APPENDIX 1: EUT PHOTO Photo 1 (For model Core300S) Photo 2 1 - Page 2 of 4 - Report No.: MTi20102216-1E1-1 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: [email protected] Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’ an District, Shenzhen, Guangdong, China. Photo 3 Photo 4 PCB antenna 1 - Page 3 of 4 - Report No.: MTi20102216-1E1-1 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: [email protected] Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’ an District, Shenzhen, Guangdong, China. Photo 5 Photo 6 1 - Page 4 of 4 - Report No.: MTi20102216-1E1-1 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: [email protected] Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’ an District, Shenzhen, Guangdong, China. Photo 7 Photo 8 ----END OF REPORT----
This test report is valid for the tested samples only. It cannot be reproduced except in full without prior written consent of Shenzhen Microtest Co., Ltd. Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: [email protected] Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’ an District, Shenzhen, Guangdong, China. MPE REPORT FCC ID: 2ARBY-CORE-300S Date of issue: Dec. 24, 2020 Report number: MTi20102216-1E4 Sample description: Smart True HEPA Air Purifier Model(s): Core 300S Applicant: Arovast corporation Address: 1202 N Miller St., Suite A, Anaheim, CA 92806, USA Date of test: Dec. 02, 2020 to Dec. 22, 2020 Shenzhen Microtest Co., Ltd. http://www.mtitest.com - Page 2 of 5 - Report No.: MTi20102216-1E4 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: [email protected] Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’ an District, Shenzhen, Guangdong, China. TEST RESULT CERTIFICATION Applicant’s name: Arovast corporation Address: 1202 N Miller St, Suite A, Anaheim, CA 92806, USA Manufacture's name: Xiamen BRI Environmental Industry Co., Ltd Address: R&D Office Building 1, 2&3 Workshop, No.30 Ma An Road, Tong An District, Xiamen, Fujian Province, P.R.China Product name: Smart True HEPA Air Purifier Trademark: LEVOIT, VESYNC Model and/or type reference: Core 300S Serial model: N/A RF exposure procedures: KDB 447498 D01 v06 This device described above has been tested by Shenzhen Microtest Co., Ltd and the test results show that the equipment under test (EUT) is in compliance with the FCC requirements. And it is applicable only to the tested sample identified in the report. Tested by: Danny Xu Dec. 22, 2020 Reviewed by: Leo Su Dec. 24, 2020 Approved by: Tom Xue Dec. 24, 2020 - Page 3 of 5 - Report No.: MTi20102216-1E4 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: [email protected] Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’ an District, Shenzhen, Guangdong, China. RF EXPOSURE EVALUATION According to FCC 1.1310: The criteria listed in the following table shall be used to evaluate the environment impact of human exposure to radio frequency (RF) Radiation as specified in §1.1307(b) Limits for Maximum Permissible Exposure (MPE) MPE Calculation Method Friis transmission formula: Pd= (Pout*G)\ (4*pi*R 2 ) Where Pd= Power density in mW/cm2 Pout=output power to antenna in mW G= Numeric gain of the antenna relative to isotropic antenna Pi=3.1415926 R= distance between observation point and center of the radiator in cm(20cm) Pd the limit of MPE, 1mW/cm2. If we know the maximum gain of the antenna and total power input to the antenna, through the calculation, we will know the distance where the MPE limit is reached. - Page 4 of 5 - Report No.: MTi20102216-1E4 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: [email protected] Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’ an District, Shenzhen, Guangdong, China. Measurement Result WIFI: Operation Frequency: WIFI 802.11b/g/n HT20: 2412-2462MHz, 802.11n HT40: 2422-2452MHz, BLE&BT: 2402-2480MHz Power density limited: 1mW/ cm 2 Antenna Type: PCB Antenna; Antenna gain: 1.44dBi R=20cm mW=10^(dBm/10) antenna gain Numeric=10^(dBi/10)= 10^(1.44/10)=1.39 Bluetooth DSS: Channel Freq. (MHz) modulation conducted power Tune- up power (dBm) Max Antenna Evaluation result Power density Limits (dBm) tune-up power Gain (mW/cm2 ) (mW/cm2) (dBm) (mW) (dBi) Numeric 2402 GFSK 5.497 6±1 7 5.012 1.44 1.39 0.0014 1 2441 6.049 6±1 7 5.012 1.44 1.39 0.0014 1 2480 6.386 6±1 7 5.012 1.44 1.39 0.0014 1 2402 π/4- DQPSK 5.124 6±1 7 5.012 1.44 1.39 0.0014 1 2441 5.768 6±1 7 5.012 1.44 1.39 0.0014 1 2480 6.129 6±1 7 5.012 1.44 1.39 0.0014 1 2402 8DPSK 5.562 6±1 7 5.012 1.44 1.39 0.0014 1 2441 6.389 6±1 7 5.012 1.44 1.39 0.0014 1 2480 6.182 6±1 7 5.012 1.44 1.39 0.0014 1 Bluetooth DTS: Channel Freq. (MHz) modulation conducted power Tune- up power (dBm) Max Antenna Evaluation result Power density Limits (dBm) tune-up power Gain (mW/cm2 ) (mW/cm2) (dBm) (mW) (dBi) Numeric 2402 GFSK 2.359 3±1 4 2.512 1.44 1.39 0.0007 1 2440 2.777 3±1 4 2.512 1.44 1.39 0.0007 1 2480 3.132 3±1 4 2.512 1.44 1.39 0.0007 1 - Page 5 of 5 - Report No.: MTi20102216-1E4 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: [email protected] Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’ an District, Shenzhen, Guangdong, China. Channel Freq. (MHz) modulation conducted power Tune- up power Max Antenna Evaluation result at 20cm Power density Limits (dBm) (dBm) tune-up power Gain Power density(mW/cm2 ) (mW/cm2) (dBm) (mW) Numeric Ant A Ant A Ant A Ant A Ant A Ant A 2412 802.11b 17.48 17±1 18 63.095734 1.39 0.01745 1 2437 17.47 17±1 18 63.095734 1.39 0.01745 1 2462 17.40 17±1 18 63.095734 1.39 0.01745 1 2412 802.11g 16.95 16±1 17 50.118723 1.39 0.01386 1 2437 16.48 16±1 17 50.118723 1.39 0.01386 1 2462 16.64 16±1 17 50.118723 1.39 0.01386 1 2412 802.11n H20 16.56 16±1 17 50.118723 1.39 0.01386 1 2437 16.36 16±1 17 50.118723 1.39 0.01386 1 2462 16.34 16±1 17 50.118723 1.39 0.01386 1 2422 802.11n H40 17.02 17±1 18 63.095734 1.39 0.01745 1 2437 16.72 17±1 18 63.095734 1.39 0.01745 1 2452 16.65 17±1 18 63.095734 1.39 0.01745 1 Conclusion: For the max result (BT+WIFI): 0.01745+0.0014=0.01885≤ 1.0 for 1g SAR, No SAR is required. ----END OF REPORT----
This test report is valid for the tested samples only. It cannot be reproduced except in full without prior written consent of Shenzhen Microtest Co., Ltd. Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: [email protected] Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’ an District, Shenzhen, Guangdong, China. Test Report FCC ID: 2ARBY-CORE-300S Date of issue: Dec. 24, 2020 Report number: MTi20102216-1E2 Sample description: Smart True HEPA Air Purifier Model(s): Core 300S Applicant: Arovast corporation Address: 1202 N Miller St, Suite A, Anaheim, CA 92806, USA Date of test: Dec. 02, 2020 to Dec. 22, 2020 Shenzhen Microtest Co., Ltd. http://www.mtitest.com - Page 2 of 66 - Report No.: MTi20102216-1E2 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: [email protected] Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’ an District, Shenzhen, Guangdong, China. Table of Contents 1 GENERAL INFORMATION .......................................................................................................................................... 5 1.1 DESCRIPTION OF EUT ................................................................................................................................................... 5 1.2 OPERATION CHANNEL LIST .............................................................................................................................................. 5 1.3 TEST CHANNEL LIST ....................................................................................................................................................... 6 1.4 ANCILLARY EQUIPMENT LIST ........................................................................................................................................... 6 1.5 DESCRIPTION OF SUPPORT UNITS .................................................................................................................................... 6 2 SUMMARY OF TEST RES U LT S .................................................................................................................................... 7 3 TEST FACILITIES AND ACCREDITATIONS ..................................................................................................................... 8 3.1 TEST LABORATORY ........................................................................................................................................................ 8 3.2 ENVIRONMENTAL CONDITIONS ........................................................................................................................................ 8 3.3 MEASUREMENT UNCERTAINTY ........................................................................................................................................ 8 3.4 TEST SOFTWARE ........................................................................................................................................................... 8 4 EQUIPMENT LIST ...................................................................................................................................................... 9 5 TEST RESULT ........................................................................................................................................................... 10 5.1 ANTENNA REQUIREMENT ............................................................................................................................................. 10 5.1.1 Standard requirement ....................................................................................................................................... 10 5.1.2 EUT antenna ..................................................................................................................................................... 10 5.2 PEAK OUTPUT POWER ................................................................................................................................................. 11 5.2.1 Limit .................................................................................................................................................................. 11 5.2.2 Test setup .......................................................................................................................................................... 11 5.2.3 Test procedure ................................................................................................................................................... 11 5.2.4 Test results......................................................................................................................................................... 11 5.3 CONDUCTED EMISSION ................................................................................................................................................ 18 5.3.1 Limits ................................................................................................................................................................. 18 5.3.2 Test setup .......................................................................................................................................................... 18 5.3.3 Test procedure ................................................................................................................................................... 19 5.3.4 Test results......................................................................................................................................................... 19 5.4 RADIATED SPURIOUS EMISSION ...................................................................................................................................... 22 5.4.1 Limits ....................................................................................................................................................…
Text truncated - open the document above for the full version.
Model: Core 300S Radiated emission Conducted emission Conducted emission
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 4.40 mW |

Air Purifier
Equipment Class
DTS - Digital Transmission SystemNeoClassic 450S Smart Ultrasonic Cool Mist Humidifier
Equipment Class
DTS - Digital Transmission System
Superior 6000S Smart Evaporative Humidifier
Equipment Class
DTS - Digital Transmission System
Smart Air Purifier
Equipment Class
DTS - Digital Transmission SystemAir fryer
Equipment Class
DTS - Digital Transmission System