Application Details

Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz
Date of Grant
Apr 02, 2023
Application Purpose
Original Equipment
Date of Application
Apr 02, 2023
Equipment Note
MagEZ Slider Dock 2
Frequency Range
0.11030000 - 0.20500000
Company
Shenzhen Lingyi Innovation Tech Co., Ltd.
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

FCC Radiation Exposure Statement The equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. During the operation of device a distance of 15 cm surrounding the device and 20 cm above the top surface of the device must be respected. FCC ID: 2ARI5-MSPD1-02 The device has been evaluated to meet general RF exposure requirement. FCC ID: 2ARI5-MBP1-02

Attestation Statements

Shenzhen Lingyi Innovation Tech Co., Ltd. 2.911 (d)(5)(i) Equipment Type Attestation v1.2 Section 2.911(d)(5)(i) Certification – Equipment Type Company name: Shenzhen Lingyi Innovation Tech Co., Ltd. Address: 12 F, Block C, Central Avenue Building, Xixiang BLVD West, Baoan District, Shenzhen China Product Name: MagEZ Slider Dock 2 FCC ID: 2ARI5-MSPD1-02 Model(s): MS1-02 2.911(d)(5)(i) Equipment Type We, [Shenzhen Lingyi Innovation Tech Co., Ltd.] (“the applicant”) certify that the equipment for which authorization is sought through certification is not: • Prohibited from receiving an equipment authorization pursuant to § 2.903; of the FCC rules. • Identified as an equipment type in the “Covered List” NOTE 1 Yours sincerely, Name: yanhui li Date: 2023-03-25 Title and Company name: General manager / Shenzhen Lingyi Innovation Tech Co., Ltd. NOTE 1 “Covered List”; is the List of Equipment and Services Covered By Section 2 of The Secure Networks Act, available at https://www.fcc.gov/supplychain/coveredlist References; 1) 986446 D01 Covered Equipment v01 https://apps.fcc.gov/oetcf/kdb/forms/FTSSearchResultPage.cfm?switch=P&id=325672 2) Federal Register document 2022-28263 published on 02/06/23 https://www.federalregister.gov/documents/2023/02/06/2022-28263/protecting-against-national-security-threats-to-the-com munications-supply-chain-through-the

Attestation Statements

Shenzhen Lingyi Innovation Tech Co., Ltd. 2.911 (d)(5)(ii) Applicant Attestation v1.3 Section 2.911(d)(5)(ii) Certification – Applicant (Covered List ) Company name: Shenzhen Lingyi Innovation Tech Co., Ltd. Address: 12 F, Block C, Central Avenue Building, Xixiang BLVD West, Baoan District, Shenzhen China Product Name: MagEZ Slider Dock 2 FCC ID: 2ARI5-MSPD1-02 Model(s): MS1-02 2.911(d)(5)(ii) Applicant filing We, [Shenzhen Lingyi Innovation Tech Co., Ltd.] (“the applicant”) certify that, as of the date of the filing of the application, the applicant is not identified NOTE 1 on the “Covered List” NOTE 2 , established pursuant to § 1.50002 of this chapter, as an entity producing covered communications equipment. Yours sincerely, Name: yanhui li Date: 2023-03-25 Title and Company name: General manager / Shenzhen Lingyi Innovation Tech Co., Ltd. NOTE 1 Delete option not applicable to this application. NOTE 2 “Covered List”; is the List of Equipment and Services Covered By Section 2 of The Secure Networks Act, available at https://www.fcc.gov/supplychain/coveredlist References; 1) 986446 D01 Covered Equipment v01 https://apps.fcc.gov/oetcf/kdb/forms/FTSSearchResultPage.cfm?switch=P&id=325672 2) Federal Register document 2022-28263 published on 02/06/23 https://www.federalregister.gov/documents/2023/02/06/2022-28263/protecting-against-national-security-threats-to-the-com munications-supply-chain-through-the

Cover Letter(s)

Shenzhen Lingyi Innovation Tech Co., Ltd. Agent Authorization Company: Shenzhen Lingyi Innovation Tech Co., Ltd. Address: 12 F, Block C, Central Avenue Building, Xixiang BLVD West, Baoan District, Shenzhen China Product Name: MagEZ Slider Dock 2 Trade Mark: N/A Model Number(s): MS1-02 FCC ID: 2ARI5-MSPD1-02 We authorize MiCOM Labs Inc., 575 Boulder Court, Pleasanton, California 94566, USA, to act on our behalf on all matters concerning the certification of above named equipment. We declare that MiCOM Labs Inc. is allowed to forward all information related to the approval and certification of equipment to the regulatory agencies as required and to discuss any issues concerning the approval application. Any and all acts carried out by MiCOM Labs on our behalf shall have the same effect as acts of our own. Signature: Date: 2023-03-25 Name: yanhui li Title: General manager Company: Shenzhen Lingyi Innovation Tech Co., Ltd.

Cover Letter(s)

Shenzhen Lingyi Innovation Tech Co., Ltd. Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 USA Date: 2023-03-25 Subject; Request for Confidentiality FCC ID: 2ARI5-MSPD1-02 To Whom It May Concern, Pursuant to the provisions of the Commission’s rules Title 47 Sections §0.457 and §0.459, we are requesting the Commission to withhold the following attachment(s) as confidential documents from public disclosure indefinitely. These documents contain detailed system and equipment descriptions and are considered as proprietary information in operation of the equipment. The public disclosure of these documents might be harmful to our company and would give competitors an unfair advantage in the market. Schematic Diagram Block Diagram Parts List Operational Description Tune-up Procedure In additional to above mentioned documents, in order to comply with the marketing regulations in Title 47 CFR §2.803 and the importation rules in Title 47 CFR §2.1204, while ensuring that business sensitive information remains confidential until the actual marketing of newly authorized devices, we request Short Term Confidentiality of the following attachment(s); External Photos Test Setup Photos Internal Photos User Manual For 45 days, pursuant to Public Notice DA 04-1705. OR For 180 days pursuant to KDB 726920 D01. It is our understanding that all measurement test reports, FCC ID label format and correspondence during the certification review process cannot be granted as confidential documents and this information will be available for public review once the grant of equipment authorization is issued. Sincerely, Signature: Name: yanhui li Title: General manager

External Photos

Page1of4FCCID:2ARI5-MSPD1-02 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity EXTERIORPHOTOGRAPHS Fig.1 Fig.2 Page2of4FCCID:2ARI5-MSPD1-02 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.3 Fig.4 Page3of4FCCID:2ARI5-MSPD1-02 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.5 Fig.6 Page4of4FCCID:2ARI5-MSPD1-02 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.7 Fig.8

ID Label/Location Info

Page1of1FCCID:2ARI5-MSPD1-02 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity LABELANDLOCATION (Size:L1cmx1cm) LabelLocation FCCID:2ARI5-MSPD1-02

Internal Photos

Page1of5FCCID:2ARI5-MSPD1-02 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity INTERIORPHOTOGRAPHS Fig.1 Fig.2 Page2of5FCCID:2ARI5-MSPD1-02 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.3 Fig.4 CoilAntenna Page3of5FCCID:2ARI5-MSPD1-02 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.5 Fig.6 Page4of5FCCID:2ARI5-MSPD1-02 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.7 Fig.8 Page5of5FCCID:2ARI5-MSPD1-02 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.9 Fig.10

RF Exposure Info

Page 1 of 10 FCCID:2ARI5-MSPD1-02 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity RFExposureEvaluationReport 1.ProductInformation FCCID:2ARI5-MSPD1-02 Numberoftestedsamples2 SamplenumberA020123185-1(Engineersample),A020123185-2(Normalsample) ProductNameMagEZSliderDock2 ModelNumberMS1-02 PowerSupply Type-CInput:9V2.22A Type-COutput:5V2A TypeC(watch)Output:5V1A WirelessOutput:5W ModulationTypeContinuousWave FrequencyRange110.3~205.0KHz AntennaTypeCoilAntenna Hardwareversion/ Softwareversion / Accessories/ ExposurecategoryGeneralpopulation/uncontrolledenvironment EUTTypeProductionUnit DeviceTypeMobileDevice 2.EvaluationMethod PerKDB680106D01Section3.RFExposureRequirements; 1)ConsumerwirelesspowertransferdevicesapprovedunderPart18insomecaseshaveto demonstratecompliancewithRFexposurerequirements.Thepotentialforexposuremustbe assessedaccordingtotheoperatingconfigurationsofthewirelesssystemandtheexposure conditionsofusersandbystanders.RFexposuremustbeevaluatedwiththeclientdevice(s)being chargedbytheprimaryatmaximumoutputpower.TheRFexposurerequirementsmustbe determinedinconjunctionwiththedeviceoperatingcharacteristics,accordingtothemobileand portableexposurerequirementsinSection2.1091andSection2.1093oftherules.SARandMPE limitsdonotcoverthefrequencyrangeforwirelesspowertransferapplicationswhichoperate below100kHzand300kHzrespectively;therefore,RFexposurecomplianceneedstobe determinedwithrespectto1.1307(c)and(d)oftheFCCrules. 2)Basedonthedesignandimplementationofthepowertransferapplication,itmustbeclearly identifiedifmobileorportableRFexposureconditionsapply.Devicesthatareinstalledtoprovide separationofatleast20cmfromusersandbystandersmayqualifyformobileexposureconditions. Forsomeconditionswhereusersandbystandersmaybeexposedatcloserthan20cm,section 2.1091(d)(4)oftherulesmayapply. 3)Fordevicesdesignedfortypicaldesktopapplications,suchawirelesschargingpads,RFexposure evaluationshouldbeconductedassumingauserseparationdistanceof15cm.EandHfield strengthmeasurementsornumericalmodelingmaybeusedtodemonstratecompliance. Measurementsshouldbemadefromallsidesandthetopoftheprimary/clientpair,withthe15cm measuredfromthecenteroftheprobe(s)totheedgeofthedevice.Emissionsbetween100kHzto 300kHzshouldbeassessedversusthelimitsat300kHzinTable1ofSection1.1310:614V/mand 1.63A/m.AKDBinquiryisrequiredtodeterminetheapplicableexposurelimitsbelow100kHz. Page 2 of 10 FCCID:2ARI5-MSPD1-02 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity 4)Portableexposureconditionsfrom100kHzto6GHzaredeterminedwithrespecttoSAR requirements.ExistingSARsystemsandtestproceduresaregenerallyintendedformeasurements above100MHz.Whilenumericalmodelingcanbeanalternative,theconstraintsofsubstantial computationalresourcesatlowfrequenciescouldintroducefurtherlimitations.Underthese circumstances,includingoperationsbelow100kHz,theCommissionmayconsideracombination ofanalyticalanalysis,fieldstrength,radiatedandconductedpowermeasurements,inconjunction withsomelimitednumericalmodelingtoassesscompliance. 5)Dependingontheoperatingfrequency,existingSARandMPEmeasurementproceduresmaybe adaptedtoevaluatewirelesspowertransferdevicesforcompliancewithrespecttomobileor portableexposureconditions.IfthegranteeoritstestlabhaveanyquestionsregardingRF exposureevaluationtheyshouldcontacttheFCCLaboratorywithsufficientsystemoperating configurationdetailstodetermineifRFexposureevaluationisnecessaryand,ifrequired,howto applyspecifictestprocedures.Below100MHz,whenSARtestingisrequiredandthedeviceis operatingatcloseproximitytopersons,informationondevicedesign,implementation,operating configurations,exposureconditionsofusersandbystandersareneededtodeterminethe evaluationandtestingrequirements.Inaddition,theinfluenceofnearbyobjectsmayalsoneed considerationaccordingtothewirelesspowertransfersystemimplementation;forexample,the effectsofplacingthedevice,itscoilsorradiatingelementsonornearmetallicsurfaces 3.EvaluationLimit 3.1Referevaluationmethod ANSIC95.1–1999:IEEEStandardforSafetyLevelswithRespecttoHumanExposuretoRadio FrequencyElectromagneticFields,3kHzto300GHz. FCCKDBpublication680106D01RFExposureWirelessChargingAppsv03:RFExposure ConsiderationsforLowPowerConsumerWirelessPowerTransferApplications FCCCFR47part11.1310:Radiofrequencyradiationexposurelimits. FCCCFR47part22.1091:Radiofrequencyradiationexposureevaluation:mobiledevices FCCCFR47part18.107:Indusial,Scientific,andMedicalEquipment Page 3 of 10 FCCID:2ARI5-MSPD1-02 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity 3.2Limit LimitsforMaximumPermissibleExposure(MPE)/ControlledExposure Frequency Range(MHz) ElectricField Strength(V/m) MagneticField Strength(A/m) PowerDensity (mW/cm²) AveragingTime (minute) LimitsforOccupational/ControlledExposure 0.3-3.06141.63*1006 3.0-301842/f4.89/f*900/f 2 6 30-30061.40.1631.06 300-1,500//f/3006 1,500-100,000//56 LimitsforMaximumPermissibleExposure(MPE)/UncontrolledExposure Frequency Range(MHz) ElectricField Strength(V/m) MagneticField Strength(A/m) PowerDensity (mW/cm²) AveragingTime (minute) LimitsforGeneralPopulation/UncontrolledExposure 0.3-1.346141.63*10030 1.34-30824/f2.19/f*180/f 2 30 30-30027.50.0730.230 300-1,500//f/150030 1,500-100,000//1.030 F=frequencyinMHz *=Plane-waveequivalentpowerdensity AccordingtoFCCKDB680106D01Section3.RFExposureRequirementsclause3the Emission-Limitsinthefrequencyrangefrom100KHzto300KHzshouldbeassessedversus thelimitsat300KHzinTable1ofCFR47–Section1.310asfoll…

Text truncated - open the document above for the full version.

Test Report

Manufacturer:ShenzhenLingyiInnovationTechCo.,Ltd. Model:MS1-02 Gain:0dBi Size:38mm*38mm

Test Report

Page1of24FCCID:2ARI5-MSPD1-02ReportNo.:LCSA020123185EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity FCCTESTREPORT For ShenzhenLingyiInnovationTechCo.,Ltd. MagEZSliderDock2 TestModel:MS1-02 Preparedfor:ShenzhenLingyiInnovationTechCo.,Ltd. Address: 12F,BlockC,CentralAvenueBuilding,XixiangBLVDWest, BaoanDistrict,ShenzhenChina Preparedby:ShenzhenLCSComplianceTestingLaboratoryLtd. Address: 101,201BldgA&301BldgC,JujiIndustrialParkShajing Street,BaoanDistrict,Shenzhen,China Tel:(+86)755-82591330 Fax:(+86)755-82591332 Web:www.LCS-cert.com Mail:[email protected] Dateofreceiptoftestsample:February23,2023 Numberoftestedsamples:2 Serialnumber:A020123185-1(Engineersample),A020123185-2(Normal sample) DateofTest:February23,2023~March01,2023 DateofReport:March02,2023 Page2of24FCCID:2ARI5-MSPD1-02ReportNo.:LCSA020123185EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity FCCTESTREPORT FCCCFR47PART15C ReportReferenceNo......................:LCSA020123185EA DateOfIssue......................................:March02,2023 TestingLaboratoryName..............:ShenzhenLCSComplianceTestingLaboratoryLtd. Address................................................: 101,201BldgA&301BldgC,JujiIndustrialParkShajingStreet, BaoanDistrict,Shenzhen,China TestingLocation/Procedure............ : FullapplicationofHarmonisedstandardsâ–  PartialapplicationofHarmonisedstandardsâ–ˇ Otherstandardtestingmethodâ–ˇ Applicant’sName.............................:ShenzhenLingyiInnovationTechCo.,Ltd. Address................................................: 12F,BlockC,CentralAvenueBuilding,XixiangBLVDWest, BaoanDistrict,ShenzhenChina TestSpecification Standard..............................................:FCCCFR47PART15C TestReportFormNo.........................:LCSEMC-1.0 TRFOriginator....................................:ShenzhenLCSComplianceTestingLaboratoryLtd. MasterTRF.........................................:Dated2011-03 ShenzhenLCSComplianceTestingLaboratoryLtd.Allrightsreserved. Thispublicationmaybereproducedinwholeorinpartfornon-commercialpurposesaslongasthe ShenzhenLCSComplianceTestingLaboratoryLtd.isacknowledgedascopyrightownerandsourceof thematerial.ShenzhenLCSComplianceTestingLaboratoryLtd.takesnoresponsibilityforandwillnot assumeliabilityfordamagesresultingfromthereader'sinterpretationofthereproducedmaterialdueto itsplacementandcontext. TestItemDescription.....................:MagEZSliderDock2 TradeMark..........................................:N/A TestModel...........................................:MS1-02 PowerSupply......................................: Type-CInput:9V2.22A Type-COutput:5V2A TypeC(watch)Output:5V1A WirelessOutput:5W Result..................................................: Positive Compiledby:Supervisedby:Approvedby: RoryHuang/AdministratorCaryLuo/Techniqueprincipal GavinLiang/Manager Page3of24FCCID:2ARI5-MSPD1-02ReportNo.:LCSA020123185EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity FCCTESTREPORT TestResultPositive Thetestreportmerelycorrespondstothetestsample. Itisnotpermittedtocopyextractsofthesetestresultwithoutthewrittenpermissionofthetest laboratory. TestReportNo.:LCSA020123185EA March02,2023 Dateofissue TestModel..............................:MS1-02 EUT.........................................:MagEZSliderDock2 Applicant...............................:ShenzhenLingyiInnovationTechCo.,Ltd. Address..................................: 12F,BlockC,CentralAvenueBuilding,XixiangBLVDWest, BaoanDistrict,ShenzhenChina Telephone...............................:/ Fax..........................................:/ Manufacturer........................:ShenzhenLingyiInnovationTechCo.,Ltd. Address...................................: 12F,BlockC,CentralAvenueBuilding,XixiangBLVDWest, BaoanDistrict,ShenzhenChina Telephone...............................:/ Fax..........................................:/ Factory...................................:ShenzhenLingyiInnovationTechCo.,Ltd. Address...................................: 12F,BlockC,CentralAvenueBuilding,XixiangBLVDWest, BaoanDistrict,ShenzhenChina Telephone...............................:/ Fax..........................................:/ Page4of24FCCID:2ARI5-MSPD1-02ReportNo.:LCSA020123185EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity RevisionHistory ReportVersionIssueDateRevisionContentRevisedBy 000March02,2023InitialIssue-- Page5of24FCCID:2ARI5-MSPD1-02ReportNo.:LCSA020123185EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity TABLEOFCONTENTS 1.GENERALINFORMATION................................................................................................................6 1.1DescriptionofDevice(EUT)........................................................................................................................6 1.2SupportequipmentList................................................................................................................................6 1.3ExternalI/OCable....................................................................…

Text truncated - open the document above for the full version.

Test Setup Photos

Page1of2FCCID:2ARI5-MSPD1-02 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity PhotographsofTestSetup ConductedEmission-ACadapterchargemode RadiatedEmissionbelow30MHz-ACadapterchargemode Page2of2FCCID:2ARI5-MSPD1-02 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity RadiatedEmissionbelow1GHz-ACadapterchargemode

Contact Information

Applicant

yanhui li(General manager)
[email protected]+86 755-23057199Fax: +86 755-23057199

Technical Contact

Shenzhen Lingyi Innovation Tech Co., Ltd.
[email protected]

China

Test Firm

Shenzhen LCS Compliance Testing Laboratory Ltd.Gavin Liang
[email protected]0755-82591330Fax: 0755-82591132

Technical Specifications

#Rule PartsFrequency RangePower Output
115C0.1103 MHz - 0.205 MHz-
Confidentiality
Long Term

Other Applications from Shenzhen Lingyi Innovation Tech Co., Ltd.

Aramid Magnetic Power Bank - FCC ID 2ARI5-PB3 - Shenzhen Lingyi Innovation Tech Co., Ltd.
2ARI5-PB3

Aramid Magnetic Power Bank

Dec 03, 2025

Equipment Class

DCD - Part 15 Low Power Transmitter Below 1705 kHz
MagEZ Car Mount Pro 2 - FCC ID 2ARI5-B2302 - Shenzhen Lingyi Innovation Tech Co., Ltd.
2ARI5-B2302

MagEZ Car Mount Pro 2

Sep 26, 2023

Equipment Class

DCD - Part 15 Low Power Transmitter Below 1705 kHz
MagEZ Battery Pack 2 - FCC ID 2ARI5-MBP1-02 - Shenzhen Lingyi Innovation Tech Co., Ltd.
2ARI5-MBP1-02

MagEZ Battery Pack 2

Apr 09, 2023

Equipment Class

DCD - Part 15 Low Power Transmitter Below 1705 kHz
2ARI5-MCST1-01

MagEZ Charging Stand for Tablets

Jul 27, 2022

Equipment Class

DCD - Part 15 Low Power Transmitter Below 1705 kHz
Wireless Power Bank - FCC ID 2ARI5-MJ2-01 - Shenzhen Lingyi Innovation Tech Co., Ltd.
2ARI5-MJ2-01

Wireless Power Bank

Jan 12, 2021

Equipment Class

DCD - Part 15 Low Power Transmitter Below 1705 kHz