2ARQ3-MTA42492Access Control System - RF readers

By TechDesign SL
Access Control System - RF readers - FCC ID 2ARQ3-MTA42492 - By TechDesign SL
Click to zoom

Application Details

Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Date of Grant
Dec 21, 2020
Application Purpose
Original Equipment
Date of Application
Dec 21, 2020
Equipment Note
Access Control System - RF readers
Frequency Range
13.56000000 - 13.56000000
Company
By TechDesign SL
Country
Spain

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗
↗

Internal Photos

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

User Manual NÜO Go! NÜO Go! Manual Content 2 ÍNDICE 1. NÜO Go! 4 1.1. equipment references 5 1.2. CONTROLLER AND SECURE DOOR UNITS 6 1.3. WIRING 12 2. Installation 13 2.1. BATTERY CONNECTION 13 2.2. SHUTTING DOWN THE EQUIPMENT 14 2.3. NÜO DC GO!8 ASSEMBLY 15 2.4. SDU AND WILI ASSEMBLY 16 2.5. SDU+ AND WILI+ ASSEMBLY 17 2.6. VIDEOCONSOLA W&M VIEW F 18 3. NÜO Go! equipment information screens 21 3.1. NÜO DC GO! 8 DISPLAY 21 3.2. DISPLAY NÜO SDU+ 26 3.3. DISPLAY WILI+ 30 4. Connect to NÜO Go! 34 4.1. CONSOLE SETTINGS (VIEW DH, VIEW D, VIEW F) 34 4.2. VOXTER/VOXTER SKY VIDEO-INTERCOM SETTINGS 34 4.3. CONTROLLER CONNECTION TO PC 35  +RZWRXVHWKHHTXLSPHQWIRUWKHðUVWWLPH 5.1. FIRST STEPS: REGISTERING A USER 39 5.1.1. Register users 39 5.2. FIRST STEPS - DOORS (ACTION AND SET UP). 42 5.2.1. Door status and actions 42 5.2.2. Set up an On-line door 44 5.2.3. :L[\WHU6ɈSPULKVVY  5.2.4. Set up an Console 46 NÜO Go! Manual Content 3 5.2.5. Set up a Video-intercom door 46 Set up warnings 47 5.2.6. Set up the lighting colours of NÜO Sky 47 5.3. REPORTS 48 5.4. MORE SYSTEM OPTIONS 51 6. Diagrams 53 6.1. CONNECTION TO NÜO DC GO! 8 53 6.1.1. CONNECTION FROM THE SDU DOOR UNITS TO NÜO DC GO! 8 53 6.1.2. NÜO SDU AND SDU+ TO NÜO DC GO! 8 CONNECTION 54 6.1.3. Detail of the connection SDU/SDU+ to NÜO DC Go!8 55 6.1.4. DIAGRAM CONNECTION OF THE ELEMENTS OF A DOOR WITH SDU 56 6.1.5. DETAILED DIAGRAM SDU CONNECTION 57 6.1.6. DIAGRAM CONNECTION OF THE ELEMENTS OF A DOOR WITH SDU+ 58 6.1.7. DETAILED DIAGRAM SDU+ CONNECTION 59 6.2. VIDEO-INTERCOM CONNECTION TO WILI/WILI+ 60 6.2.1. VIDEO-INTERCOM CONNECTION VOXTER TO WILI 60 6.2.2. Voxter and Readers connection to WILI+ 61 6.2.3. CONNECTION FROM SKY FLUX/SURF SUPPORT TO WILI+ 62 6.2.4. CONNECTION OF SKY POST 63 6.2.5. CONNECTION OF SKY CAR POST/WALK WITH WILI+ 64 6.3. W&M CONNECTION TO POE SWITCH 65 7. Information regarding the NÜO DC Go! product 66 NÜO Go! Manual Introduction 4 ;LJOUPJHS:WLJPÄJH[PVUZHUK.LULYHS-LH[\YLZ This manual must be read completely in order to avoid problems and confusion during installation which could cause irreparable failures to the system. ;OLPUZ[HSSH[PVUHUK^PYPUNVM[OPZWYVK\J[ZOV\SKILZ\WLY]PZLKI`X\HSPÄLKWLYZVUULS and treated with caution. Follow the instructions at all times. Do not use abrasive materials to clean the product such as bleach or ammonia. Clean it using a damp cloth with water and/or mild soap. NÜO GO! DIAGRAM Installation Diagram 1. NÜO Go! Red BB4 BB4 BB4 BB4 1 BB2 DC Go! 8 SDU 2 BB2 SDU 3 BB2 SDU 4 BB2 SDU 5 BB2 6 BB2 SDUSDU 7 BB2 SDU 8 BB2 SDU AC SDU SDUSDUSDU SDUSDUSDU 1 BB2 DC Go! 8 SDU 2 BB2 SDU 3 BB2BB2 SDU+ 5 BB2 SDU 6 BB2 SDU AC SDU SDU SDUSDU Alternative Configuration with SDU and SDU + 4 BB2BB2 SDU+ Voxter WILI + WILI Reader Reader Sky Flux/Surf Sky Flux/Surf Voxter WILI WILI + 4 Access control doors with videointercommunication 4 consoles W&M View UTP UTP UTP UTP UTP BB2 BB2 BB4 BB2 BB4 BB2 BB4 BB4 48 Off-line doors with NÜO Tok electronic locks BB4 BB4 BB4 BB4 One SDU + occupies an entire bus, so the number of doors is reduced. UTP Up to 8 access control doors The NÜO Go! system is an access control system for 250 users, 8 On-line doors, 48 Off-line doors and 4 Video-intercom doors. The NÜO Go! System consists of a Multi-Door IP Controller, NÜO DC Go!8, which can manage up to 4 On-line doors and 48 Off-line doors, and can be extended to up to 20 On-line doors using the NÜO DC Slave units. By means of WILI/WILI+, 4 Video-intercom doors can be added. ,WKDVDV\VWHPFDSDFLW\RIXSWRXVHUVZLWKFDUGVDQGÀQJHUSULQWV The NÜO Go! application is embedded in the controller. It can be connected to directly through a browser from any device such as a computer or a tablet. NÜO Go! Manual Introduction 5 ;LJOUPJHS:WLJPÄJH[PVUZHUK.LULYHS-LH[\YLZ NÜO GO! GENERAL FEATURES 1²2'&*R -IP Controller with embedded application. -Set up from any a browser on any device (computer or tablet). -TFT-LCD touch screen 1.77” for monitoring the status of the entire installation -Multi-door management -max. 8 On-Line doors, -TH_6ќ3PULKVVYZ^P[OLSLJ[YVUPJSVJRZHUK+H[H6U*HYKJVTT\UPJH[PVU -max. 4 Video-intercom doors. -Up to 4 Video-consoles for Video-intercom. -\ZLYZ^P[OJHYKZHUKÄUNLYWYPU[Z -Manages authorisations for 25 access groups and 25 timetables. -Compatible with all NÜO readers. -Ethernet connection. -Steel casing with a tough polycarbonate frame -Operating temperature: : -10 ºC a 50 ºC. This manual serves as an installation and operation guide for the following equipment: • Ref. 42552 - NÜO DC Go! 8 • Ref. 42530 - NÜO SDU • Ref. 42550 - NÜO SDU+ • Ref. 42532 - NÜO WILI (SDUY15) • Ref. 42545 - NÜO WILI+ (SDUY50) • Ref. 42451 - W&M View 1.1. EQUIPMENT REFERENCES NÜO Go! Manual Introduction 6 ;LJOUPJHS:WLJPÄJH[PVUZHUK.LULYHS-LH[\YLZ NÜO SDU+·SECURE DOOR UNIT FOR 2 READER + I/O (REF: 42550)· INPUT VOLTAGE48 VDC POWER 1,5 W stand-by 2,5 W maximum CONNECTIONS 2 Readers 3VJR 1 Magnetic sensor 1 Entry Button 2 Inputs and 2 Outputs OPERATING TEMPERATURE -10ºC to 50ºC DIMENSIONSHeight 196, Width 116, Depth 49,4 mm NÜO DC GO! 8 ·CONTROLLER (REF: 42552)· INPUT VOLTAGE In: 100 - 240 VAC Out: 48VDC POWER 12 W (without any connected elements) 120 W (with 8 doors and their terminals, without Batteris); 30W máximo por bus Number of doors8 Number of readersPer door: 1 with SDU, 2 with SDU+ BATERÍA Sealed Lead-Acid (SLA) or GEL batteries. > 4 hours of autonomy (4 doors) > 2,5 hours of autonomy (8 doors) OPERATING TEMPERATURE -10ºC to 50ºC DIMENSIONSHeight 348, Width 348, Depth 75 mm 1.2. CONTROLLER AND SECURE DOOR UNITS NÜO SDU ·SECURE DOOR UNIT FOR 1 READER (REF: 42530)· INPUT VOLTAGE48 VDC POWER 0,45 W stand-by 1 W maximum CONNECTIONS 1 Reader 3VJR 1 Magnetic sensor 1 Entry Button OPERATING TEMPERATURE -10ºC to 50ºC DIMENSIONSHeight 107, Width 107, Depth 43,8 mm NÜO Go! Manual Introduction 7 ;LJOUPJHS:WLJPÄJH[PVUZHUK.LULYHS-LH[\YLZ For door units, The “LOCK 24V” output …

Text truncated - open the document above for the full version.

Attestation Statements

BY TECHDESIGN S.L. Calle Thomas Edison 5, Arganda del Rey Madrid, 28500, Spain Product Similarity Declaration Date: September 22, 2020 FCC ID: 2ARQ3-MTA42492 Model Number: 42492, 42493, 42534, 42535, 42536, 42540 To: Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD To Whom It May Concern, We, BY TECHDESIGN S.L., declare that this EUT (Access Control System – RF readers ) Model Number: 42492, 42493, 42534, 42535, 42536, 42540 board, Schematic, Hardware version, Software version, structure and internal photos are same, named differently due to marketing purposes. Model name Type Brand Power supply and input / output Model difference 42492 Polo NÜO SDU or SUD+ for NÜO Polo: Input: 24VDC, 2.0W All models are same included the hardware and software, except of the exterior’s color and the model name. 42493 42534 42535 42536 42540 Should you have any questions or comments regarding this matter, please have my best attention. Sincerely, (Signed) Name / Title: Inmaculada Ortiz / General Manager Company: BY TECHDESIGN S.L. Address: Calle Thomas Edison 5, Arganda del Rey Madrid, 28500, Spain Phone: 34918707193 Fax: Email:

Cover Letter(s)

BY TECHDESIGN S.L. C5266091_X8_Ed. 1 Letter of Authorization Company: BY TECHDESIGN S.L. Address: Calle Thomas Edison 5, Arganda del Rey Madrid, 28500, Spain Product Name: Access Control System - RF readers Model Number: 42492, 42493, 42534, 42535, 42536, 42540 FCC Identifier: 2ARQ3-MTA42492 We authorize LGAI Technological Center S.A., Ronda de la Font del Carme, s/n, 08193 Bellaterra, Spain, to act on our behalf on all matters concerning the FCC certification of the above named equipment. Any individual within LGAI Technological Center S.A. is authorized to act on our behalf and take action on the application. We declare that authorize LGAI Technological Center S.A., Ronda de la Font del Carme, s/n, 08193 Bellaterra, Spain,, is allowed to forward all information related to the approval project to the Federal Communication Commission and to discuss any issues concerning the approval application. Any and all acts carried out by LGAI Technological Center S.A. on our behalf shall have the same effect as acts of our own. Name: Inmaculada Ortiz Date: 2020-09-22 Title: General Manager Signature of applicant: C.I.F. 8\�16885 气怎言。五怎言'8�ey 1/1

External Photos

Page 1 of 9 External Photos of EUT 42492 EUT-1 EUT-2 FCC ID: 2ARQ3-MTA42492 Page 2 of 9 EUT-3 EUT-4

ID Label/Location Info

Label location 0013BE28 FCC ID: 2ARQ3-MTA42534 Ref: 42534 POLO Input: 24V 0.1A

Internal Photos

Page 3 of 9 EUT-5 EUT-6 FCC ID: 2ARQ3-MTA42492 Page 4 of 9 Internal Photos of EUT 42492 EUT-1 EUT-2 Page 5 of 9 EUT-3 EUT-4 Page 6 of 9 EUT-5 EUT-6 Page 7 of 9 EUT-7 EUT-8 Page 8 of 9 EUT-9 EUT-10 Page 9 of 9 EUT-11 EUT-12 --------------------This is the last page of the report. ----------------------- BT Antenna BT IC NFC Antenna

Test Report

Report No.: E202008101990-10 Application No.: E202008101990 Page 1 of 25 DIRECTIONS OF TEST 1. This station carries out test task according to the national regulation of verifications which can be traced to National Primary Standards and BIPM. 2. The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test result without the written permission of the test laboratory. 3. If there is any objection concerning the test, the client should inform the laboratory within 15 days from the date of receiving the test report. Report No.: E202008101990-10 Application No.: E202008101990 Page 2 of 25 TABLE OF CONTENTS 1. TEST RESULT SUMMARY ............................................................................................................................ 3 2. GENERAL DESCRIPTION OF EUT ................................................................................................................. 4 2.1 APPLICANT ................................................................................................................................................... 4 2.2 MANUFACTURER ........................................................................................................................................ 4 2.3 FACTORY ...................................................................................................................................................... 4 2.4 BASIC DESCRIPTION OF EQUIPMENT UNDER TEST ............................................................................ 4 2.5 TEST OPERATION MODE ........................................................................................................................... 5 2.6 LOCAL SUPPORTIVE ................................................................................................................................... 5 2.7 TEST SOFTWARE ......................................................................................................................................... 5 3. LABORATORY AND ACCREDITATIONS ........................................................................................................ 6 3.1 LABORATORY .............................................................................................................................................. 6 3.2 ACCREDITATIONS ...................................................................................................................................... 6 3.3 MEASUREMENT UNCERTAINTY ............................................................................................................. 6 4. LIST OF USED TEST EQUIPMENT AT GRGT .................................................................................................. 7 5. CONDUCTED EMISSION MEASUREMENT .................................................................................................... 8 5.1 LIMITS ........................................................................................................................................................... 8 5.2 TEST PROCEDURES ..................................................................................................................................... 8 5.3 TEST SETUP .................................................................................................................................................. 9 5.4 DATA SAMPLE ............................................................................................................................................. 9 5.5 TEST RESULTS ........................................................................................................................................... 10 6. IN BAND AND OUT BAND RADIATED SPURIOUS EMISSIONS ...................................................................... 12 6.1 LIMITS ......................................................................................................................................................... 12 6.2 TEST PROCEDURES ................................................................................................................................... 12 6.3 MEASURING INSTRUMENTS SETTING ................................................................................................. 14 6.4 TEST SETUP ................................................................................................................................................ 14 6.5 DATA SAMPLE ........................................................................................................................................... 15 6.6 TEST RESULTS ........................................................................................................................................... 16 6.6.1 IN BAND RADIATED SPURIOUS EMISSIONS ................................................................................. 16 6.6.2 OUT BAND RADIATED SPURIOUS EMISSIONS ............................................................................. 18 7. 20DB BANDWIDTH ................................................................................................................................... 22 7.1 LIMITS ......................................................................................................................................................... 22 7.2 TEST PROCEDURES ................................................................................................................................... 22 7.3 TEST SETUP ................................................................................................................................................ 22 7.4 TEST RESULTS ........................................................................................................................................... 23 8. FREQUENCY TOLERANCE (TEMPERATURE VARIATION AND VOLTAGE VARIATION) .................................... 24 8.1 LIMITS ..........................................................…

Text truncated - open the document above for the full version.

Test Setup Photos

Conducted Emission on AC mains 0.15MHz to 30MHz FCC ID: 2ARQ3-MTA42492 Radiated Spurious Emission Test(Below 1GHz)

Contact Information

Applicant

Inmaculada Tardio Ortiz
[email protected]34918707193Fax: 34918707193

Technical Contact

FANGGUANG Inspection & Testing Co., Ltd.Sabrina wang
[email protected]61180008-8612

Tianjin · China

Test Firm

GRG Metrology & Test Group Co., Ltd.Frank Chen
[email protected]86-20-66830999-8358

Technical Specifications

#Rule PartsFrequency RangePower Output
115C13.56 MHz - 13.56 MHz-
Confidentiality
Long Term

Other Applications from By TechDesign SL

Biometric Reader - FCC ID 2ARQ3-MTA42513 - By TechDesign SL
2ARQ3-MTA42513

Biometric Reader

Jul 04, 2022

Equipment Class

DTS - Digital Transmission System
Access Control System - RF readers - FCC ID 2ARQ3-MTA42272 - By TechDesign SL
2ARQ3-MTA42272

Access Control System - RF readers

Dec 21, 2020

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
Access Control System - RF readers - FCC ID 2ARQ3-MTA42520 - By TechDesign SL
2ARQ3-MTA42520

Access Control System - RF readers

Dec 21, 2020

Equipment Class

DTS - Digital Transmission System
Access Control System - RF readers - FCC ID 2ARQ3F-MTA42553 - By TechDesign SL
2ARQ3F-MTA42553

Access Control System - RF readers

Dec 21, 2020

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter