Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Sentek TM Sentek IoT Hardware Manual Version 1.0 Copyright © 2019 Sentek Pty Ltd All rights reserved Page i All rights reserved. No part of this document may be reproduced, transcribed, translated into any language or transmitted in any form electronic or mechanical for any purpose whatsoever without the prior written consent of Sentek Pty Ltd. All intellectual and property rights remain with Sentek Pty Ltd. All information presented is subject to change without notice. © 2019 Sentek Pty Ltd Sentek™, EnviroSCAN™, EasyAG™, TriSCAN™, IrriMAX™, IrriMAX Live™ and Drill& Drop™ are trademarks or registered trademarks of Sentek Pty Ltd that may be registered in one or more jurisdictions. Bluetooth™ is a trademark of the Bluetooth Special Interest Group (Bluetooth.org) Android is a trademark of Google Inc. Sentek Pty Ltd A.C.N. 007 916 672 77 Magill Road Stepney, South Australia 5069 Phone: +61 8 8366 1900 Facsimile: +61 8 8362 8400 Internet: www.sentek.com.au Email: [email protected] Sentek IoT Rev 1.0 (2019-11-18) Copyright © 2019 Sentek Pty Ltd All rights reserved Page ii SENTEK - SENTEK IOT - STATEMENTS OF COMPLIANCE FCC COMPLIANCE STATEMENT This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Information to user This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna. • Increase the distance between the equipment and the receiver. • Connect the equipment to outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help. EMC APPROVALS Pending ROHS • EN 50581:2012 Technical documentation for the assessment of electrical and electronic products with respect to the restriction of hazardous substances. Copyright © 2019 Sentek Pty Ltd All rights reserved Page iii TABLE OF CONTENTS Sentek - Sentek IoT - Statements of Compliance ........................................... ii FCC Compliance statement ............................................................................................. ii EMC approvals................................................................................................................ ii RoHS.............................................................................................................................. ii Introduction ....................................................................................................1 Background..................................................................................................................... 1 Features ......................................................................................................................... 1 Hardware Requirement Lists For Sentek IoT ..................................................................... 1 Referenced Documents ...................................................................................3 System Setup ..................................................................................................4 Internet Provisioning ........................................................................................................ 4 Data Transfer and Hosting ........................................................................................... 4 Sentek IoT Dtu Setup....................................................................................................... 4 Sentek IoT Probe Setup ................................................................................................... 5 System Test .................................................................................................................... 5 Viewing Data ................................................................................................................. 11 Maintenance .................................................................................................. 12 DTU.............................................................................................................................. 12 Probe............................................................................................................................ 12 Cabling ......................................................................................................................... 12 Solar Panel ................................................................................................................... 12 battery Life .................................................................................................................... 12 Appendix A – Modem information ................................................................. 13 BuilD In Modem............................................................................................................. 13 SIM Card ...................................................................................................................... 13 Appendix B – Response Fields ..................................................................... 14 Last Response .............…
Text truncated - open the document above for the full version.
CONFIDENTIALITY REQUEST for Certification Service in USA Federal Communication Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21046 Date: 2020/06/28 TO WHOM IT MAY CONCERN Pursuant to Paragraphs §0.457 and 0.459 of the Commission’s Rules (47 C.F.R.) and Section §552(b)(4) of the Freedom of Information Act, we requests confidentiality for the following products: FCC ID Model name 2ARQB-SM200 Sentek Modem SM200 V1.3 For the product stated above, we request that the following information be held confidential; Exhibits Long-Term Confidentiality Short-Term Confidentiality Short-Term Confidentiality Days External Photos Internal Photos Block Diagram Schematics Test Setup Photos User’s Manual Parts List Tune Up Operational Descriptions The long-term confidentiality exhibits contain our trade secrets and proprietary information that could be of benefit to our competitors. The short-term confidentiality on the basis of ensuring that business sensitive information remains confidential until the actual marketing of our new device. If you have any questions, please feel free to contact me at the address shown below. Sincerely, Name: Michael Portmann Company: Sentek Pty Ltd Address: 77 Magill Road, Stepney 5069, South Australia, Australia Phone: +61 883661900 Fax: N/A E-Mail: [email protected]
DATE : 2020-06-28 Federal Communications Commission Authorization & Evaluation Division 7345 Oakland Mills Road Columbia, Maryland 21046 Authority to Act as Agent On our behalf, I appoint Shenzhen CTL Testing Technology Co., Ltd.(MR. Tracy Qi) at Floor 1-A, Baisha Technology Park, No. 3011, Shahexi Road, Nanshan, Shenzhen 518055 China (Name of Agent company name and address) to act as our agent in the preparation of this application for equipment certification. I certify that submitted documents properly describe the device or system for which equipment certification is sought. I also certify that each unit manufactured, imported or marketed, as defined in the Federal Communications Commission’s regulations will have affixed to it a label identical to that submitted for approval with this application. For instances where our authorized agent signs the application for certification on our behalf, I acknowledge that all responsibility for complying with the terms and conditions for certification, still resides with S e n t e k P t y L t d a t 7 7 M a g i l l R o a d , S t e p n e y 5 0 6 9 , S o u t h A u s t r a l i a , A u s t r a l i a (Applicant Name and address) Signature: Name: Michael Portmann Title: Manager Applicant Company: Sentek Pty Ltd
FCC ID Label Information 1. Label location: 2. FCC ID Label: Sentek IoT Model:Sentek Modem SM200 V1.3 FCC ID:2ARQB-SM200 This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Label Size:90mm(L)×60mm(W) FCCID Label Location
BT Antenna
RF Exposure evaluation FCC ID:2ARQB-SM200 1. Reference According to §1.1307(b)(1), systems operating under the provisions of this section shall be operated in a manner that ensures that the public is not exposed to radio frequency energy level in excess of the Commission’s guidelines. According to §1.1310 and §2.1091 RF exposure is calculated. KDB447498 D01: Mobile and Portable Devices RF Exposure Procedures and Equipment Authorization Policies 2. Limit Limits for Maximum Permissible Exposure (MPE)/Controlled Exposure Frequency Range(MHz) Electric Field Strength(V/m) Magnetic Field Strength(A/m) Power Density (mW/cm²) Averaging Time (minute) Limits for Occupational/Controlled Exposure 0.3 – 3.0 3.0 – 30 30 – 300 300 – 1500 1500 – 100,000 614 1842/f 61.4 / / 1.63 4.89/f 0.163 / / (100) * (900/f 2 )* 1.0 f/300 5 6 6 6 6 6 Limits for Maximum Permissible Exposure (MPE)/Uncontrolled Exposure Frequency Range(MHz) Electric Field Strength(V/m) Magnetic Field Strength(A/m) Power Density (mW/cm²) Averaging Time (minute) Limits for Occupational/Controlled Exposure 0.3 – 3.0 3.0 – 30 30 – 300 300 – 1500 1500 – 100,000 614 824/f 27.5 / / 1.63 2.19/f 0.073 / / (100) * (180/f 2 )* 0.2 f/1500 1.0 30 30 30 30 30 F=frequency in MHz *=Plane-wave equivalent power density 3. MPE Calculation Method Predication of MPE limit at a given distance Equation from page 18 of OET Bulletin 65, Edition 97-01 S=PG/4πR² Where: S=power density P=power input to antenna G=power gain of the antenna in the direction of interest relative to an isotropic radiator R=distance to the center of radiation of the antenna 4. Result As declared by the Applicant, the EUT is a wireless device used in a fix application, at least 20 cm from any body part of the user or nearby persons; from the maximum EUT RF output power, the minimum separation distance, r =20cm, as well as the gain of the LTE antenna is 7dBi, the gain of the BT antenna is 0dBi, the RF power density can be obtained. Band Frequen cy (MHz) Max. Outpu t Power (dBm) Max. Output Power (mW) Antenna Gain (Numeric) Power Density At 20 cm (mW/cm 2 ) Power Density Limit FCC (mW/cm 2 ) Test Result s LTE band 2 1850.7 21.69 147.5707 5.0119 0.1471 1.0000 PASS LTE band 4 1710.7 22.35 171.7908 5.0119 0.1713 1.0000 PASS LTE band 5 836.5 23.33 215.2782 5.0119 0.2146 0.5577 PASS LTE band 12 707.5 23.09 203.7042 5.0119 0.2031 0.4665 PASS LTE band 13 779.5 23.11 204.6445 5.0119 0.2040 0.5197 PASS LTE band 14 790.5 23.39 218.2730 5.0119 0.2176 0.5270 PASS LTE band 17 706.5 23.19 208.4491 5.0119 0.2078 0.4710 PASS LTE band 25 1850.7 21.12 129.4196 5.0119 0.1290 1.0000 PASS LTE band 26 824.7 23.90 245.4709 5.0119 0.2448 0.5498 PASS LTE band 66 1710.7 22.87 193.6422 5.0119 0.1931 1.0000 PASS BLE 2480 8.16 6.5464 1.0000 0.0013 1.0000 PASS 5. Conclusion The SAR evaluation is not required.
Shenzhen CTL Testing Technology Co., Ltd. Tel: +86-755-89486194 E-mail: [email protected] TEST REPORT FCC Part 24 Subpart E Report Reference No. ................ : CTL1909294031-WF01 Compiled by: ( position+printed name+signature) Happy Guo (File administrators) Tested by: ( position+printed name+signature) Nice Nong (Test Engineer) Approved by: ( position+printed name+signature) Ivan Xie (Manager) Product Name ............................ : Sentek IoT Model/Type reference ................ : Sentek Modem SM200 V1.3 List Model(s) ............................... : N/A Trade Mark .................................. : N/A FCC ID ......................................... : 2ARQB-SM200 Applicant’s name ....................... : Sentek Pty Ltd Address of applicant ................. : 77 Magill Road, Stepney 5069, South Australia, Australia Test Firm ..................................... : Shenzhen CTL Testing Technology Co., Ltd. Address of Test Firm ................. : Floor 1-A, Baisha Technology Park, No.3011, Shahexi Road, Nanshan District, Shenzhen, China 518055 Test specification ....................... : Standard ...................................... : FCC CFR Title 47 Part 2, Part 24E ANSI/TIA/EIA-603-E:2016 KDB 971168 D01 TRF Originator ............................. : Shenzhen CTL Testing Technology Co., Ltd. Master TRF .................................. : Dated 2011-01 Date of receipt of test item ........ : Sep. 30, 2019 Date of sampling ........................ : Sep. 30, 2019 Date of Test Date ........................ : Sep. 30, 2019–Apr. 03, 2020 Data of Issue............................... : Apr. 03, 2020 Result .......................................... : Pass Shenzhen CTL Testing Technology Co., Ltd. All rights reserved. This publication may be reproduced in whole or in part for non-commercial purposes as long as the Shenzhen CTL Testing Technology Co., Ltd. is acknowledged as copyright owner and source of the material. Shenzhen CTL Testing Technology Co., Ltd. takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. V1.0 Page 2 of 39 Report No.: CTL1909294031-WF01 TEST REPORT Test Report No. : CTL1909294031-WF01 Apr. 03, 2020 Date of issue Equipment under Test : Sentek IoT Model /Type : Sentek Modem SM200 V1.3 Listed Models : N/A Applicant : Sentek Pty Ltd Address : 77 Magill Road, Stepney 5069, South Australia, Australia Manufacturer : Sentek Pty Ltd Address : 77 Magill Road, Stepney 5069, South Australia, Australia Test result Pass * *In the configuration tested, the EUT complied with the standards specified page 5. The test results presented in this report relate only to the object tested. This report shall not be reproduced, except in full, without the written approval of the issuing testing laboratory. V1.0 Page 3 of 39 Report No.: CTL1909294031-WF01 ** Modified History ** Revisions Description Issued Data Report No. Remark Version 1.0 Initial Test Report Release 2020-04-03 CTL1909294031-WF01 Tracy Qi V1.0 Page 4 of 39 Report No.: CTL1909294031-WF01 Table of Contents Page 1. SUMMARY ............................................................................................................................................................... 5 1.1. TEST STANDARDS ..................................................................................................................................................... 5 1.2. TEST DESCRIPTION ........................................................................................................................................................ 5 1.3. TEST FACILITY .............................................................................................................................................................. 6 1.4. STATEMENT OF THE MEASUREMENT UNCERTAINTY ............................................................................................................... 6 2. GENERAL INFORMATION .......................................................................................................................................... 7 2.1. ENVIRONMENTAL CONDITIONS ........................................................................................................................................ 7 2.2. GENERAL DESCRIPTION OF EUT ...................................................................................................................................... 7 2.3. DESCRIPTION OF TEST MODES ........................................................................................................................................ 7 2.4. EQUIPMENTS USED DURING THE TEST .............................................................................................................................. 9 2.5. RELATED SUBMITTAL(S) / GRANT (S) ................................................................................................................................ 9 2.6. MODIFICATIONS ........................................................................................................................................................... 9 3. TEST CONDITIONS AND RESULTS ............................................................................................................................ 10 3.1. OUTPUT POWER ........................................................................................................................................................ 10 3.2. PEAK-TO-AVERAGE RATIO (PAR) ................................................................................................................................... 15 3.3. OCCUPIED BANDWIDTH AND EMISSION BANDWIDTH ......................................................................................................... 18 3.4. BAND EDGE COMPLIANCE .................................................................................................................…
Text truncated - open the document above for the full version.
Shenzhen CTL Testing Technology Co., Ltd. Tel: +86-755-89486194 E-mail: [email protected] TEST REPORT FCC Part 27 Report Reference No. ................ : CTL1909294031-WF02 Compiled by: ( position+printed name+signature) Happy Guo (File administrators) Tested by: ( position+printed name+signature) Nice Nong (Test Engineer) Approved by: ( position+printed name+signature) Ivan Xie (Manager) Product Name ............................ : Sentek IoT Model/Type reference ................ : Sentek Modem SM200 V1.3 List Model(s) ............................... : N/A Trade Mark .................................. : N/A FCC ID ......................................... : 2ARQB-SM200 Applicant’s name ....................... : Sentek Pty Ltd Address of applicant ................. : 77 Magill Road, Stepney 5069, South Australia, Australia Test Firm ..................................... : Shenzhen CTL Testing Technology Co., Ltd. Address of Test Firm ................. : Floor 1-A, Baisha Technology Park, No.3011, Shahexi Road, Nanshan District, Shenzhen, China 518055 Test specification ....................... : Standard ...................................... : FCC CFR Title 47 Part 2, Part 27 ANSI/TIA/EIA-603-E:2016 KDB 971168 D01 TRF Originator ............................. : Shenzhen CTL Testing Technology Co., Ltd. Master TRF .................................. : Dated 2011-01 Date of receipt of test item ........ : Sep. 30, 2019 Date of sampling ........................ : Sep. 30, 2019 Date of Test Date ........................ : Sep. 30, 2019–Apr. 03, 2020 Data of Issue............................... : Apr. 03, 2020 Result .......................................... : Pass Shenzhen CTL Testing Technology Co., Ltd. All rights reserved. This publication may be reproduced in whole or in part for non-commercial purposes as long as the Shenzhen CTL Testing Technology Co., Ltd. is acknowledged as copyright owner and source of the material. Shenzhen CTL Testing Technology Co., Ltd. takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. V1.0 Page 2 of 39 Report No.: CTL1909294031-WF02 TEST REPORT Test Report No. : CTL1909294031-WF02 Apr. 03, 2020 Date of issue Equipment under Test : Sentek IoT Model /Type : Sentek Modem SM200 V1.3 Listed Models : N/A Applicant : Sentek Pty Ltd Address : 77 Magill Road, Stepney 5069, South Australia, Australia Manufacturer : Sentek Pty Ltd Address : 77 Magill Road, Stepney 5069, South Australia, Australia Test result Pass * *In the configuration tested, the EUT complied with the standards specified page 5. The test results presented in this report relate only to the object tested. This report shall not be reproduced, except in full, without the written approval of the issuing testing laboratory. V1.0 Page 3 of 39 Report No.: CTL1909294031-WF02 ** Modified History ** Revisions Description Issued Data Report No. Remark Version 1.0 Initial Test Report Release 2020-04-03 CTL1909294031-WF02 Tracy Qi V1.0 Page 4 of 39 Report No.: CTL1909294031-WF02 Table of Contents Page 1. SUMMARY ............................................................................................................................................................... 5 1.1. TEST STANDARDS ..................................................................................................................................................... 5 1.2. TEST DESCRIPTION ........................................................................................................................................................ 5 1.3. TEST FACILITY .............................................................................................................................................................. 6 1.4. STATEMENT OF THE MEASUREMENT UNCERTAINTY ............................................................................................................... 6 2. GENERAL INFORMATION .......................................................................................................................................... 7 2.1. ENVIRONMENTAL CONDITIONS ........................................................................................................................................ 7 2.2. GENERAL DESCRIPTION OF EUT ...................................................................................................................................... 7 2.3. DESCRIPTION OF TEST MODES ........................................................................................................................................ 7 2.4. EQUIPMENTS USED DURING THE TEST .............................................................................................................................. 9 2.5. RELATED SUBMITTAL(S) / GRANT (S) ................................................................................................................................ 9 2.6. MODIFICATIONS ........................................................................................................................................................... 9 3. TEST CONDITIONS AND RESULTS ............................................................................................................................ 10 3.1. OUTPUT POWER ........................................................................................................................................................ 10 3.2. PEAK-TO-AVERAGE RATIO (PAR) ................................................................................................................................... 15 3.3. OCCUPIED BANDWIDTH AND EMISSION BANDWIDTH ......................................................................................................... 18 3.4. BAND EDGE COMPLIANCE ............................................................................................................................…
Text truncated - open the document above for the full version.
Shenzhen CTL Testing Technology Co., Ltd. Tel: +86-755-89486194 E-mail: [email protected] TEST REPORT FCC Part 22 Subpart H Report Reference No. ................ : CTL1909294031-WF03 Compiled by: ( position+printed name+signature) Happy Guo (File administrators) Tested by: ( position+printed name+signature) Nice Nong (Test Engineer) Approved by: ( position+printed name+signature) Ivan Xie (Manager) Product Name ............................ : Sentek IoT Model/Type reference ................ : Sentek Modem SM200 V1.3 List Model(s) ............................... : N/A Trade Mark .................................. : N/A FCC ID ......................................... : 2ARQB-SM200 Applicant’s name ....................... : Sentek Pty Ltd Address of applicant ................. : 77 Magill Road, Stepney 5069, South Australia, Australia Test Firm ..................................... : Shenzhen CTL Testing Technology Co., Ltd. Address of Test Firm ................. : Floor 1-A, Baisha Technology Park, No.3011, Shahexi Road, Nanshan District, Shenzhen, China 518055 Test specification ....................... : Standard ...................................... : FCC Part 22 Subpart H ANSI/TIA/EIA-603-E:2016 KDB 971168 D01 TRF Originator ............................. : Shenzhen CTL Testing Technology Co., Ltd. Master TRF .................................. : Dated 2011-01 Date of receipt of test item ........ : Sep. 30, 2019 Date of sampling ........................ : Sep. 30, 2019 Date of Test Date ........................ : Sep. 30, 2019–Apr. 03, 2020 Data of Issue............................... : Apr. 03, 2020 Result .......................................... : Pass Shenzhen CTL Testing Technology Co., Ltd. All rights reserved. This publication may be reproduced in whole or in part for non-commercial purposes as long as the Shenzhen CTL Testing Technology Co., Ltd. is acknowledged as copyright owner and source of the material. Shenzhen CTL Testing Technology Co., Ltd. takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. V1.0 Page 2 of 39 Report No.: CTL1909294031-WF03 TEST REPORT Test Report No. : CTL1909294031-WF03 Apr. 03, 2020 Date of issue Equipment under Test : Sentek IoT Model /Type : Sentek Modem SM200 V1.3 Listed Models : N/A Applicant : Sentek Pty Ltd Address : 77 Magill Road, Stepney 5069, South Australia, Australia Manufacturer : Sentek Pty Ltd Address : 77 Magill Road, Stepney 5069, South Australia, Australia Test result Pass * *In the configuration tested, the EUT complied with the standards specified page 5. The test results presented in this report relate only to the object tested. This report shall not be reproduced, except in full, without the written approval of the issuing testing laboratory. V1.0 Page 3 of 39 Report No.: CTL1909294031-WF03 ** Modified History ** Revisions Description Issued Data Report No. Remark Version 1.0 Initial Test Report Release 2020-04-03 CTL1909294031-WF03 Tracy Qi V1.0 Page 4 of 39 Report No.: CTL1909294031-WF03 Table of Contents Page 1. SUMMARY ............................................................................................................................................................... 5 1.1. TEST STANDARDS ..................................................................................................................................................... 5 1.2. TEST DESCRIPTION ........................................................................................................................................................ 5 1.3. TEST FACILITY .............................................................................................................................................................. 6 1.4. STATEMENT OF THE MEASUREMENT UNCERTAINTY ............................................................................................................... 6 2. GENERAL INFORMATION .......................................................................................................................................... 7 2.1. ENVIRONMENTAL CONDITIONS ........................................................................................................................................ 7 2.2. GENERAL DESCRIPTION OF EUT ...................................................................................................................................... 7 2.3. DESCRIPTION OF TEST MODES ........................................................................................................................................ 7 2.4. EQUIPMENTS USED DURING THE TEST .............................................................................................................................. 9 2.5. RELATED SUBMITTAL(S) / GRANT (S) ................................................................................................................................ 9 2.6. MODIFICATIONS ........................................................................................................................................................... 9 3. TEST CONDITIONS AND RESULTS ............................................................................................................................ 10 3.1. OUTPUT POWER ........................................................................................................................................................ 10 3.2. PEAK-TO-AVERAGE RATIO (PAR) ................................................................................................................................... 15 3.3. OCCUPIED BANDWIDTH AND EMISSION BANDWIDTH ......................................................................................................... 18 3.4. BAND EDGE COMPLIANCE .............................................................................................................................…
Text truncated - open the document above for the full version.
Shenzhen CTL Testing Technology Co., Ltd. Tel: +86-755-89486194 E-mail: ctl@ctl-l…
Text truncated - open the document above for the full version.
| # | Rule Parts | Frequency Range | Power Output | Emission | Tolerance |
|---|---|---|---|---|---|
| 22 | 9 | 814.7 MHz - 823.3 MHz | 230.10 mW | 1M09W7D | 0.01 ppm |

IoT Probe
Equipment Class
DTS - Digital Transmission System