
Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: -- Reorient or relocate the receiving antenna. -- Increase the separation between the equipment and receiver. -- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -- Consult the dealer or an experienced radio/TV technician for help. Warning: changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment
C5266091_X8_Ed.1 1/1 LetterofAuthorization VTrumpTech(Shanghai)Co.,Ltd Company:VTrumpTech(Shanghai)Co.,Ltd Address:Room508,1888YiShanRoad,Shanghai ProductName:KegelCoach ModelNumber:SMV21 FCCIdentifier:2ARV3-SMV21 WeauthorizeLGAITechnologicalCenterS.A.,RondadelaFontdelCarme,s/n, 08193Bellaterra,Spain,toactonourbehalfonallmattersconcerningthe abovenamedequipment. AnyindividualwithinLGAITechnologicalCenterS.A.isauthorizedtoactonour behalfandtakeactionontheapplication. WedeclarethatauthorizeLGAITechnologicalCenterS.A.,RondadelaFontdel Carme,s/n,08193Bellaterra,Spain,isallowedtoforwardallinformation relatedtotheapprovalprojecttotheFederalCommunicationCommissionand todiscussanyissuesconcerningtheapprovalapplication.Anyandallacts carriedoutbyLGAITechnologicalCenterS.A.onourbehalfshallhavethe sameeffectasactsofourown. Name:XIESHENGXIDate:January19,2021 Title:Manager Signatureofapplicant:
C5266091_X10_Ed.2 1/1 VTrumpTech(Shanghai)Co.,Ltd OfficeofEngineeringTechnology FederalCommunicationsCommission 7435OaklandMillsRoad Columbia,MD21046 Date:January19,2021 Subject:RequestforConfidentiality FCCID:2ARV3-SMV21 ToWhomItMayConcern, PursuanttotheprovisionsofSections0.457and0.459ofCommission'srules (47CFR0.457,0.459),wearerequestingtheCommissiontowithholdthefollowing attachment(s)asconfidentialdocumentfrompublicdisclosure. ExhibitsLong-Term Confidentiality Short-Term Confidentiality NOTE2 IDLabel/LocationNoNo AttestationStatementNoNo ExternalPhotosNo â BlockDiagram ââ Schematics ââ TestReportNoNo TestSetupPhotosNo â UserâsManual â NOTE 1 â InternalPhotos â NOTE 1 â PartsList/TuneUp ââ RFExposureInfoNoNo OperationalDescription ââ CoverLetter(s)NoNo SDRSoftware/SecurityInfo â No NOTE1:Long-TermConfidentialitymaybepermittedunderspecialconditions(SeeII.LONG-TERMCONFIDENTIALITY,Section3of KDB726920,uselastinforce) NOTE2:Short-TermConfidentialitycanberequestedforamaximumof180daysfromthedateofthegrant. Abovementioneddocumentcontainsdetailedsystemandequipmentdescriptionare consideredasproprietaryinformationinoperationoftheequipment.Thepublic disclosureofabovedocumentsmightbeharmfultoourcompanyandwouldgive competitoranunfairadvantageinthemarket. Incaseofshort-termConfidentiality,theapplicantrequeststheexhibitsselected abovearewithheldfrompublicviewforaperiodof______daysfromthedateofthe GrantofEquipmentAuthorizationandpriortomarketing. Itisourunderstandingthatallmeasurementtestreports,FCCIDlabelformatand correspondentduringcertificationreviewprocesscannotbegrantedasconfidential documentsandthoseinformationwillbeavailableforpublicreviewoncethegrantof equipmentauthorizationisissued. C5266091_X10_Ed.2 1/1 Sincerely, Signature: Name:XIESHENGXI Title:Manager
Page1of3ReportNo.:FCS202101015 Externalphotos Photo1 Photo2 Page2of3ReportNo.:FCS202101015 Photo3 Photo4 Page3of3ReportNo.:FCS202101015 Photo5 Photo6
LabelandLabelLocation FCCID:2ARV3-SMV21 L*W:10mm*7mm whitefontonaBlacklabel
Page1of3ReportNo.:FCS202101015 Photo1 Photo2 Page 2 of 3Report No.:FCS202101015 Photo 3 Antenna Photo 4 CC2541 Page3of3ReportNo.:FCS202101015 Photo5
FCCTestReport ReportNo:FCS202101015W01 Issuedfor Applicant: VTrumpTech(Shanghai)co.,Ltd Address: Room508,1888YiShanRoad,Shanghai ProductName: KegelCoach BrandName: MagicMotion ModelName: SMV21 SeriesModel: N/A FCCID: 2ARV3-SMV21 IssuedBy:FluxComplianceServiceLaboratory Add:Room105FloorBaohaoTechnologyBuilding1NO.15GongyeWestRoadHi-Tech Industrial,SongshanlakeDongguan Tel:769-27280901Fax:769-27280901http://www.fcs-lab.com Page2of34ReportNo.:FCS202101015W01 FluxComplianceServiceLaboratory Room105FloorBaohaoTechnologyBuilding1NO.15GongyeWestRoadHi-TechIndustrial,SongshanlakeDongguan Tel:769-27280901Fax:769-27280901http://www.fcs-lab.com TESTRESULTCERTIFICATION ApplicantâsName......................:VTrumpTech(Shanghai)co.,Ltd Address......................................:Room508,1888YiShanRoad,Shanghai Manufacture'sName ................ :VTrumpTech(Shanghai)co.,Ltd Address ...................................... :Room508,1888YiShanRoad,Shanghai ProductDescription ProductName...........................:KegelCoach BrandName ............................. :MagicMotion ModelName..............................:SMV21 SeriesModel .............................. :N/A TestStandards..........................:FCCRulesandRegulationsPart15SubpartC,Section249 TestProcedure .......................... :ANSIC63.10:2013 ThisdevicedescribedabovehasbeentestedFCS,thetestresultsshowthattheequipmentundertest (EUT)isincompliancewiththeFCCrequirements.Anditisapplicableonlytothetestedsample identifiedinthereport. Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofFCS,thisdocument maybealteredorrevisedbyFCS,personalonly,andshallbenotedintherevisionofthedocument.. DateofTest .................................. : Date(s)ofperformanceoftests.:08Jan.2021~15Jan.2021 DateofIssue.................................:15Jan.2021 TestResult.....................................:Pass Testedby: (ScottShen) Reviewedby : (DukeQian) Approvedby: (KaitChen) Page3of34ReportNo.:FCS202101015W01 FluxComplianceServiceLaboratory Room105FloorBaohaoTechnologyBuilding1NO.15GongyeWestRoadHi-TechIndustrial,SongshanlakeDongguan Tel:769-27280901Fax:769-27280901http://www.fcs-lab.com TableofContentsPage 1.SUMMARYOFTESTRESULTS5 1.1TESTFACTORY6 1.2MEASUREMENTUNCERTAINTY6 2.GENERALINFORMATION7 2.1GENERALDESCRIPTIONOFTHEEUT7 2.2DESCRIPTIONOFTHETESTMODES9 2.3DESCRIPTIONOFNECESSARYACCESSORIESANDSUPPORTUNITS10 2.4EQUIPMENTSLIST11 3CONDUCTEDEMISSIONMEASUREMENT12 3.1LIMIT12 3.2TESTPROCEDURE12 3.3TESTSETUP13 3.4TESTRESULTS14 4.RADIATEDEMISSIONMEASUREMENT16 4.1LIMIT16 4.2TESTPROCEDURE17 4.3TESTSETUP18 4.4TESTRESULTS19 5.BANDEDGETEST25 5.1LIMIT25 5.2TESTPROCEDURE25 5.3TESTSETUP26 5.4TESTRESULTS27 6.20DBBANDWIDTHTEST31 6.1LIMIT31 6.2TESTPROCEDURE31 6.3TESTSETUP31 6.4TESTRESULTS32 7.ANTENNAREQUIREMENT34 7.1STANDARDREQUIREMENT34 7.2EUTANTENNA34 Page4of34ReportNo.:FCS202101015W01 FluxComplianceServiceLaboratory Room105FloorBaohaoTechnologyBuilding1NO.15GongyeWestRoadHi-TechIndustrial,SongshanlakeDongguan Tel:769-27280901Fax:769-27280901http://www.fcs-lab.com RevisionHistory Rev.IssueDateEffectPageContents 0015Jan.2021AllInitialIssue Page5of34ReportNo.:FCS202101015W01 FluxComplianceServiceLaboratory Room105FloorBaohaoTechnologyBuilding1NO.15GongyeWestRoadHi-TechIndustrial,SongshanlakeDongguan Tel:769-27280901Fax:769-27280901http://www.fcs-lab.com 1.SUMMARYOFTESTRESULTS FCCPart15.249,SubpartC Standard Section TestItemJudgmentRemark 15.207ConductedEmissionPASS-- 15.205(a),15.209(a), 15.249(a),15.249(c) RadiatedSpuriousEmissionPASS-- 15.209FieldstrengthoffundamentalPASS 15.249(d)BandEdgeEmissionPASS-- 15.215(c)20dBBandwidthPASS-- 15.203AntennaRequirementPASS-- NOTE: (1)âN/AâdenotestestisnotapplicableinthisTestReport (2)AlltestsareaccordingtoANSIC63.10-2013 Page6of34ReportNo.:FCS202101015W01 FluxComplianceServiceLaboratory Room105FloorBaohaoTechnologyBuilding1NO.15GongyeWestRoadHi-TechIndustrial,SongshanlakeDongguan Tel:769-27280901Fax:769-27280901http://www.fcs-lab.com 1.1TESTFACTORY CompanyName:FluxComplianceServiceLaboratory Address: Room105FloorBaohaoTechnologyBuilding1NO.15Gongye WestRoadHi-TechIndustrial,SongshanlakeDongguan Telephone:+86-769-27280901 Fax:+86-769-27280901 FCCTestFirmRegistrationNumber:514908 Designationnumber:CN0127 A2LAaccreditationnumberïŒ5545.01 1.2MEASUREMENTUNCERTAINTY Thereporteduncertaintyofmeasurementy±U,whereexpendeduncertaintyUisbasedona standarduncertaintymultipliedbyacoveragefactorofk=2,providingalevelofconfidenceof approximately95%. No.ItemUncertainty 1RFoutputpower,conducted±0.71dB 2UnwantedEmissions,conducted±2.98dB 3ConductedEmission(9KHz-150KHz) ±4.13dB 4ConductedEmission(150KHz-30MHz) ±4.74dB 5Allemissions,radiated(<1G)30MHz-1000MHz ±3.2dB 6Allemissions,radiated(1GHz-18GHz) ±3.66dB 7Allemissions,radiated(18GHz-40GHz) ±4.31dB Page7of34ReportNo.:FCS202101015W01 FluxComplianceServiceLaboratory Room105FloorBaohaoTechnologyBuilding1NO.15GongyeWestRoadHi-TechIndustrial,SongshanlakeDongguan Tel:769-27280901Fax:769-27280901http://www.fcs-lab.com 2.GENERALINFORMATION 2.1GENERALDESCRIPTIONOFTHEEUT ProductName KegelCoach TradeName MagicMotion ModelName SMV21 SeriesModel N/A ModelDifference N/A ChannelList PleaserefertotheNote2. BT Frequency:2402-2480MHz Modulation:GFSK Datarate:1Mbps Channelnumber:40CH PowerSupply Input:5V,300mA Output:3.7V HardwareversionnumberV1.0 SoftwareversionnumberV1.0 ConnectingI/OPort(s)PleaserefertotheUser'sManual Note: 1. Foramoredetailedfeaturesdescription,pleaserefertothemanufacturerâsspecifications ortheUser'sManual. Page8of34ReportNo.:FCS202101015W01 FluxComplianceServiceLaboratory Room105FloorBaohaoTechnologyBuilding1NO.15GongyeWestRoadHi-TechIndustrial,SongshanlakeDongguan Tel:769-27280901Fax:769-27280901http://www.fcs-lab.com 2. 3.TableforFiledAntenna Ant.Brand Model Name AntennaTypeConnectorGain(dBi)NOTE 1NADYRTPCBAntennaN/A1.0Antenna Page9of34ReportNo.:FCS202101015W01 FluxComplianceServiceLaboratory Room105FloorBaohaoTechnologyBuilding1NO.15GongyeWestRoadHi-TechIndustrial,SongshanlakeDongguan TelâŠ
Text truncated - open the document above for the full version.
Page 1 of2ReportNo.:FCS202101015 Above1GHzforradiatedemissiontestsetup Blow1GHzforradiatedemissiontestsetup Page 2 of2ReportNo.:FCS202101015 Conductionemissiontestingdevice
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | - |

Flamingo Max
Equipment Class
DTS - Digital Transmission System
An Interactive Stroker Sync with Video
Equipment Class
DTS - Digital Transmission System
Solstice X
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Sundae
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Lotos
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter