FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. VTrump Tech (Shanghai) Co., Ltd/
  3. 2ARV3-SMV45

2ARV3-SMV45Flamingo Max

VTrump Tech (Shanghai) Co., Ltd
Flamingo Max - FCC ID 2ARV3-SMV45 - VTrump Tech (Shanghai) Co., Ltd
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Sep 08, 2024
Application Purpose
Original Equipment
Date of Application
Sep 08, 2024
Equipment Note
Flamingo Max
Frequency Range
2402.00000000 - 2480.00000000
Company
VTrump Tech (Shanghai) Co., Ltd
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

X Note: Please insert the charging pin fully into the charging port. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: -- Reorient or relocate the receiving antenna. -- Increase the separation between the equipment and receiver. -- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -- Consult the dealer or an experienced radio/TV technician for help. Warning: changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment The devices has been evaluated to meet general RF exposure requirement the device can be used in portable exposure condition without restriction

Attestation Statements

1/1 US Agent for Service of Process LETTER OF ATTESTATION TO: Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 US Agent for Service of Process: Company Name: Wilson Tech Service LLC FRN: 0033402033 Contact Name: Wilson Cheung Address: 1312 17th Street Suite 692,Denver,CO,80202,US Telephone No: +1-716-965-5112 Email: [email protected] [VTrump Tech (Shanghai) Co., Ltd ] certifies that, as of the date of this filing of the application with the TCB, [Wilson Tech Service LLC] is our designated US agent for service of process for the above referenced FCC ID. [VTrump Tech (Shanghai) Co., Ltd ] accepts to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any commission related proceeding involving equipment. [Wilson Tech Service LLC] accepts, as of the date of the filing of the application, the obligation of the designated US Applicant: Company name:VTrump Tech (Shanghai) Co., Ltd FRN:0022135230 Product Description:Smart Knob Lock with Fingerprint and Keypad Grantee code:2ARV3 FCC ID:2ARV3-SMV45 Contact Name: SHENGXI XIE Address:Room 508, 1888 Yishan Road, Minhang District, Shanghai Telephone No:+86-021-64052517 Email:[email protected] agent for service of process for the above reference FCC ID. The US Agent for Service of Process is aware of and agrees to comply with the requirements outlined in the FCC Equipment Authorization Program, Report and Order FCC 22-84, and clause § 2.911. The Applicant is aware of and agrees to comply with the requirements outlined in the FCC Equipment Authorization Program, Report and Order FCC 22-84, and clause § 2.911. Date: 2024/09/09 Applicant’s Name: S HENGXI XIE US Agent’s Name: Wilson Cheung Title:Manager Title: Manager Signature Signature

Attestation Statements

C5266091_X24_Ed.2 1/1 VTrump Tech (Shanghai) Co., Ltd “Attestation Statements” TO: Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 The Commission adopted rules that prohibit equipment authorization for “covered” telecommunications equipment and video surveillance equipment produced by entities identified on the Commission’s Covered List 1 , which is periodically updated. See the Covered List for more details. This Attestation Statement is to confirm that we follow the Section 2.911(d)(5)(i)-(ii) Applicant Company name: VTrump Tech (Shanghai) Co., Ltd FRN:0022135230 Grantee code: 2ARV3 FCC ID: 2ARV3-SMV45 Contact Name: SHENG XI XIE Address: Room 508, 1888 Yishan Road, Minhang District, Shanghai Telephone No: 862164052517 Fax No: 862164052517 Email: [email protected] i. [VTrump Tech (Shanghai) Co., Ltd] (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. The applicant must sign this certification. ii. [VTrump Tech (Shanghai) Co., Ltd] (“the applicant”) certifies that, as of the date of the filing of the application, the applicant [is not] (as a specifically named entity or any of its subsidiaries or affiliates) identified on the Covered List as an entity producing “covered” equipment. The applicant must sign this certification. [VTrump Tech (Shanghai) Co., Ltd] (“the applicant”) certifies that, as of the date of the filing of the application, the applicant [is not] identified on the Covered List as an entity producing “covered”equipment . Date: 2024/09/05 Applicant’s Name: SHENG XI XIE Title: Manager Signature 1 The Commission’s Covered List is published by the Public Safety and Homeland Security Bureau and posted on the Commission’s website. This Covered List, which is periodically updated, identifies particular equipment, produced by particular entities, that constitutes “covered” equipment. https://www.fcc.gov/supplychain/coveredlist C5266091_X24_Ed.2 1/1

Cover Letter(s)

C5266091_X8_Ed.1 1/1 Letter of Authorization Company: VTrump Tech (Shanghai) Co., Ltd Address: Room 508, 1888 Yishan Road, Minhang District, Shanghai Product Name: Flamingo Max Model Number: SMV45 We authorize LGAI Technological Center S.A., Ronda de la Font del Carme, s/n, 08193 Bellaterra, Spain, to act on our behalf on all matters concerning the above named equipment. Any individual within LGAI Technological Center S.A. is authorized to act on our behalf and take action on the application. We declare that authorize LGAI Technological Center S.A., Ronda de la Font del Carme, s/n, 08193 Bellaterra, Spain, is allowed to forward all information related to the approval project to the Federal Communication Commission and to discuss any issues concerning the approval application. Any and all acts carried out by LGAI Technological Center S.A. on our behalf shall have the same effect as acts of our own. Name: SHENG XI XIE Date: 2024.09.06 Title: Manager Signature of applicant:

Cover Letter(s)

C5266091_X10_Ed.2 1/1 VTrump Tech (Shanghai) Co., Ltd Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 Date: 2024.9.5 Subject: Request for Confidentiality FCC ID: 2ARV3-SMV45 To Whom It May Concern, Pursuant to the provisions of Sections 0.457 and 0.459 of Commission's rules (47CFR0.457, 0.459), we are requesting the Commission to withhold the following attachment(s) as confidential document from public disclosure. Exhibits Long-Term Confidentiality Short-Term Confidentiality NOTE 2 ID Label/Location No No Attestation Statement No No External Photos No ☐ Block Diagram ☒ ☐ Schematics ☒ ☐ Test Report No No Test Setup Photos No ☐ User’s Manual ☐ NOTE 1 ☐ Internal Photos ☐ NOTE 1 ☐ Parts List / Tune Up ☐ ☐ RF Exposure Info No No Operational Description ☒ ☐ Cover Letter(s) No No SDR Software / Security Info ☐ No NOTE 1: Long-Term Confidentiality may be permitted under special conditions (See II. LONG-TERM CONFIDENTIALITY, Section 3 of KDB 726920, use last in force) NOTE 2: Short-Term Confidentiality can be requested for a maximum of 180 days from the date of the grant. Above mentioned document contains detailed system and equipment description are considered as proprietary information in operation of the equipment. The public disclosure of above documents might be harmful to our company and would give competitor an unfair advantage in the market. In case of short-term Confidentiality, the applicant requests the exhibits selected above are withheld from public view for a period of ______ days from the date of the Grant of Equipment Authorization and prior to marketing. It is our understanding that all measurement test reports, FCC ID label format and correspondent during certification review process cannot be granted as confidential documents and those information will be available for public review once the grant of equipment authorization is issued. C5266091_X10_Ed.2 1/1 Sincerely, Signature: Name: SHENG XI XIE Title: Manager 2024.09.05

External Photos

Page1of3ReportNo.:FCS202409016 Externalphotos Photo1 Photo2 Page2of3ReportNo.:FCS202409016 Photo3 Photo4 Page3of3ReportNo.:FCS202409016 Photo5 Photo6

ID Label/Location Info

LabelandLabelLocation FCCID:2ARV3-SMV45

Internal Photos

Page1of4ReportNo.:FCS202409016 Internalphotos Photo1 Photo2 Page2of4ReportNo.:FCS202409016 Photo3 Photo4 Internalantenna Page3of4ReportNo.:FCS202409016 Photo5 Photo6 Page4of4ReportNo.:FCS202409016 Photo7

RF Exposure Info

FCCRFExposure EUTDescription:FlamingoMax ModelNo.:SMV45 SeriesModel:N/A FCCID:2ARV3-SMV45 Equipmenttype:PortableDevice 1.TestProcedure AccordingtoKDB447498D01GeneralRFExposureGuidancev06 The1-gand10-gSARtestexclusionthresholdsfor100MHzto6GHzattest separationdistances ≤ 50mmaredeterminedby: [(max.powerofchannel,includingtune-uptolerance,mW)/ (min.testseparationdistance,mm)]·[√f(GHz)]≤3.0for1-gSARand≤7.5for10-g extremitySAR, where f(GHz)istheRFchanneltransmitfrequencyinGHz PoweranddistanceareroundedtothenearestmWandmmbefore calculationTheresultisroundedtoonedecimalplaceforcomparison Thetestexclusionsareapplicableonlywhentheminimumtestseparation distanceis ≤ 50mmandfortransmissionfrequenciesbetween100MHzand6GHz. Whentheminimumtestseparationdistanceis<5mm,adistanceof5mmisappliedto determineSARtestexclusion. 2.TestResultofRFExposureEvaluation BLE [(max.powerofchannel,includingtune-uptolerance,mW)/(min.testseparation distance,mm)]·[√f(GHz)]=0.5767/5*√2.440=0.180166≤3.0ThresholdatwhichnoSARrequired isand≤3.0for1-gSAR,Separationdistanceis5mm. Conclusion : NoSARrequired Mode Channel Freq.(MHz) Maximum Conducted Output Power(PK) AntennaGain (dBi) Antenna gainnumeric Maxtune- uppower (W) GFSK 2402-2.800.591.150.0005248 2440-2.390.591.150.0005767 2480-2.820.591.150.0005223

Test Report

FCCTestReport ReportNo:FCS202409016W01 Issuedfor Applicant: VTrumpTech(Shanghai)Co.,Ltd Address: Room508,No.1888YishanRoad,MinhangDistrict, Shanghai ProductName: FlamingoMax BrandName: MagicMotion ModelName: SMV45 SeriesModel: N/A FCCID: 2ARV3-SMV45 IssuedBy:FluxComplianceServiceLaboratory Add:Room105FloorBaohaoTechnologyBuilding1NO.15GongyeWestRoadHi-Tech Industrial,SongshanlakeDongguan Tel:769-27280901Fax:769-27280901http://www.FCS-lab.com Page 2 of35ReportNo.:FCS202409016W01 FluxComplianceServiceLaboratory Room105FloorBaohaoTechnologyBuilding1NO.15GongyeWestRoadHi-TechIndustrial,SongshanlakeDongguan Tel:769-27280901Fax:769-27280901http://www.FCS-lab.com TESTRESULTCERTIFICATION Applicant’sName......................:VTrumpTech(Shanghai)Co.,Ltd Address ...................................... :Room508,No.1888YishanRoad,MinhangDistrict,Shanghai Manufacture'sName................:VTrumpTech(Shanghai)Co.,Ltd Address......................................:Room508,No.1888YishanRoad,MinhangDistrict,Shanghai ProductDescription ProductName ........................... :FlamingoMax BrandName ............................... :MagicMotion ModelName..............................:SMV45 SeriesModel..............................:N/A TestStandards .......................... :FCCRulesandRegulationsPart15SubpartC,Section247 TestProcedure..........................:ANSIC63.10:2013 ThisdevicedescribedabovehasbeentestedbyFluxComplianceServiceLaboratory,thetestresults showthattheequipmentundertest(EUT)isincompliancewiththeFCCrequirements.Anditis applicableonlytothetestedsampleidentifiedinthereport. Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofFluxCompliance ServiceLaboratory,thisdocumentmaybealteredorrevisedbyFluxComplianceServiceLaboratory, personalonly,andshallbenotedintherevisionofthedocument.. DateofTest..................................: Date(s)ofperformanceoftests . :September2,2024~September4,2024 DateofIssue.................................:September4,2024 TestResult....................................:Pass Testedby: (ScottShen) Reviewedby : (DukeQian) Approvedby: (JackWang) Page 3 of35ReportNo.:FCS202409016W01 FluxComplianceServiceLaboratory Room105FloorBaohaoTechnologyBuilding1NO.15GongyeWestRoadHi-TechIndustrial,SongshanlakeDongguan Tel:769-27280901Fax:769-27280901http://www.FCS-lab.com TableofContentsPage 1.SUMMARYOFTESTRESULTS...........................................................................................6 1.1TESTFACTORY............................................................................................................7 1.2MEASUREMENTUNCERTAINTY.................................................................................7 2.GENERALINFORMATION...................................................................................................8 2.1GENERALDESCRIPTIONOFTHEEUT.......................................................................8 2.2BLOCKDIGRAMSHOWINGTHECONFIGURATIONOFSYSTEMTESTED............10 2.3DESCRIPTIONOFNECESSARYACCESSORIESANDSUPPORTUNITS...............11 2.4EQUIPMENTSLIST.....................................................................................................12 3.CONDUCTEDEMISSIONMEASUREMENT.......................................................................13 4.6DBBANDWIDTH...............................................................................................................17 4.1Limit..............................................................................................................................17 4.2TestProcedure.............................................................................................................17 4.3Testsetup.....................................................................................................................17 4.4Testresults...................................................................................................................17 4.5OriginalTestData.........................................................................................................18 5.CONDUCTEDOUTPUTPOWER........................................................................................19 5.1LIMIT............................................................................................................................19 5.2TESTPROCEDURE.....................................................................................................19 5.3TESTSETUP...............................................................................................................19 5.5TESTRESULTS...........................................................................................................19 6.BANDEDGEANDSPURIOUS(CONDUCTED)..................................................................20 6.1LIMIT............................................................................................................................20 6.2TESTPROCEDURE.....................................................................................................20 6.3TESTSETUP...............................................................................................................20 6.4TESTRESULTS...........................................................................................................21 6.5Originaltestdata..........................................................................................................21 7.POWERSPECTRALDENSITY...........................................................................................23 7.1LIMIT............................................................................................................................23 7.2TESTPROCEDURE.....................................................................................................23 Page 4 of35ReportNo.:FCS202409016W01 FluxComplianceServiceLaboratory Room105FloorBaohaoTechnologyBuilding1NO.15GongyeWestRoadHi-TechIndustrial,SongshanlakeDongguan Tel:769-27280901Fax:769-27280901http://www.F…

Text truncated - open the document above for the full version.

Test Report

Dongzhen Electronics Co., Ltd Shangpin Science and Technology Building, Xinjin Street, Longhu District, Shantou City customer Antenna Specification for Approval Product Name: 2.4G antenna SMV45 Part NO.: *151.50±61.20 Write By: Mr. zhou Issued Date: 2024-4-7 : R&D Dept Business Dept Approved By supplier R&D Dept Engineer Dept Approval Product Specification A. Electrical Characteristics Frequency 2400MHz ~2500MHz VSWR <3.0 Efficiency >20% Impedance 50 Ohm Gain 0.59 dBi Polarization mode: linear polarization B. Material & Mechanical Characteristics Material of Radiator Cu Cable Type 1.4 white Connector Type : NO Dimension C. Environmental Operation Temperature - 30 °C ~ + 80 °C Storage Temperature - 30 °C ~ + 85 °C Test Equipment & Conditions 1. Network Analyzers: Agilent 8753D 5071B 2. Communications Test Set: Agilent E5515C 3. 3D Chamber Test System Effiency &Gain Freq (MHz) Effi (%) Gain (dBi) 2400 23.66 0.47 2410 23.19 0.38 2420 23.03 0.49 2430 22.41 0.42 2440 21.67 0.45 2450 20.24 0.52 2460 20.61 0.51 2470 21.41 0.59 2480 23.89 0.56 2490 26.46 0.53 2500 25.73 0.46 Radiation Pattern

Test Setup Photos

Page 1 of2ReportNo.:FCS202409016 Below1GHzforradiatedemissiontestsetup Above1GHzforradiatedemissiontestsetup Page 2 of2ReportNo.:FCS202409016 Conductedemissiontestsetup

Contact Information

Applicant

SHENG XI XIE
[email protected]+862164052517Fax: +862164052517

Technical Contact

Flux Compliance Service LaboratoryAndy yue
[email protected]+86-769-27280901

Dongguang · China

Test Firm

Flux Compliance Service LaboratoryAndy Yue
[email protected]13510297284

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz600.00 µW
Confidentiality
Long Term
Grant Notes
Output power listed is conducted.

Other Applications from VTrump Tech (Shanghai) Co., Ltd

An Interactive Stroker Sync with Video - FCC ID 2ARV3-XONE - VTrump Tech (Shanghai) Co., Ltd
2ARV3-XONE

An Interactive Stroker Sync with Video

Jun 29, 2023

Equipment Class

DTS - Digital Transmission System
Solstice X - FCC ID 2ARV3-SMV42 - VTrump Tech (Shanghai) Co., Ltd
2ARV3-SMV42

Solstice X

Apr 23, 2023

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
Kegel Coach - FCC ID 2ARV3-SMV21 - VTrump Tech (Shanghai) Co., Ltd
2ARV3-SMV21

Kegel Coach

Jan 20, 2021

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
Sundae - FCC ID 2ARV3-SMV23 - VTrump Tech (Shanghai) Co., Ltd
2ARV3-SMV23

Sundae

Nov 19, 2020

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
Lotos - FCC ID 2ARV3-SMV18 - VTrump Tech (Shanghai) Co., Ltd
2ARV3-SMV18

Lotos

Nov 19, 2020

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter