Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
2 IMPORTANT SAFETY INSTRUCTIONS PG 002 PRE-SETUP PG 009 INSTALLATION PG 012 USING THE SPA PG 012 MAINTENANCE PG 014 DISASSEMBLY AND STORAGE PG 014 TROUBLESHOOTING PG 015 ERROR CODES PG 017 CONTENTS Visit the Bestway YouTube channel OWNER’S MANUAL S400105/S400205 READ AND FOLLOW ALL INSTRUCTIONS. Carefully read, understand, and follow all information in this user manual before installing and using the spa. These warnings, instructions, and safety guidelines address some common risks of water recreation, but they cannot cover all risks and dangers in all cases. Always use caution, common sense, and good judgment when enjoying any water activity. Retain this information for future use. In addition, the following information can be supplied depending on the spa type. Keep these instructions in a safe place. If instructions are missing, please contact the manufacturer or search it on the website www.bestwayusa.com. IMPORTANT SAFETY INSTRUCTIONS WE SUGGEST NOT TO RETURN THE PRODUCT TO THE STORE QUESTIONS? PROBLEMS? MISSING PARTS? For FAQ, Manuals, Videos Or Spare Parts, Please Visit bestwayusa.com/ourwarranties V i s i t w w w . b e s t w a y u s a . c o m / o u r w a r r a n t i e s f o r h e l p 3 WARNING IMPORTANT SAFETY INSTRUCTIONS When using this electrical equipment, basic safety precautions should always be followed, including the following: READ AND FOLLOW ALL INSTRUCTIONS. WARNING – To reduce the risk of injury, do not permit children to use this product unless they are closely supervised at all times. A wire connector is provided on this unit to connect a minimum 8 AWG (8.37 mm 2 ) solid copper conductor between this unit and any metal equipment, metal enclosures of electrical equipment, metal water pipe, or conduit within 5 feet (1.5 m) of the unit. DANGER – Risk of injury. a) Replace damaged cord immediately. b) Do not bury cord. c) Connect to a grounded, grounding type receptacle only. WARNING – This product is provided with a ground-fault circuit-interrupter integrated with the power plug at the end of the cord. The GFCI must be tested before each use. With the product operating, push the test button on the GFCI and the product should not operate. Push the reset button on the GFCI and the product should now operate normally. When the product fails to operate in this manner, there is a ground current flowing indicating the possibility of an electrical shock. Disconnect the power until the fault has been identified and corrected. DANGER – Risk of Accidental Drowning. Extreme caution must be exercised to prevent unauthorized access by children. To avoid accidents, ensure that children cannot use this spa unless they are supervised at all times. DANGER – Risk of Injury. The suction fittings in this spa are sized to match the specific water flow created by the pump. Should the need arise to replace the suction fittings or the pump, be sure that the flow rates are compatible. Never operate spa if the suction fittings are broken or missing. Never replace a suction fitting with one rated less than the flow rate marked on the original suction fitting. DANGER – Risk of Electric Shock. Install at least 5 feet (1.5 m) from all metal surfaces. As an alternative, a spa may be installed within 5 feet of metal surfaces if each metal surface is permanently connected by a minimum 8 AWG (8.37 mm 2 ) solid copper conductor to the wire connector on the terminal box that is provided for this purpose. DANGER – Risk of Electric Shock. Do not permit any electric appliance, such as a light, telephone, radio, or television, within 5 feet (1.5 m) of a spa. WARNING – To reduce the risk of injury: a) The water in a spa should never exceed 104°F (40°C). Water temperatures between 100°F (38°C) and 104°F (40°C) are considered safe for a healthy adult. Lower water temperatures are recommended for young children and when spa use exceeds 10 minutes. b) Since excessive water temperatures have a high potential for causing fetal damage during the early months of pregnancy, pregnant or possibly pregnant women should limit spa water temperatures to 100°F (38°C). c) Before entering a spa, the user should measure the water temperature with an accurate thermometer since the tolerance of water temperature-regulating devices varies. d) The use of alcohol, drugs, or medication before or during spa use may lead to unconsciousness with the possibility of drowning. e) Obese persons and persons with a history of heart disease, low or high blood pressure, circulatory system problems, or diabetes should consult a physician before using a spa. f ) Persons using medication should consult a physician before using a spa since some medication may induce drowsiness while other medication may affect heart rate, blood pressure, and circulation. WARNING: To avoid electric shock, do not use the spa during storms in case of thundering or lighting. In case of rain always keeping plug dry, plug in with wet plug is definitely forbidden. Hyperthermia occurs when the internal temperature of the body reaches a level several degrees above the normal body temperature of 98.6°F (37°C). The symptoms of hyperthermia include an increase in the internal temperature of the body, dizziness, lethargy, drowsiness, and fainting. The effects of hyperthermia include failure to perceive heat, failure to recognize the need to exit spa or hot tub, unawareness of impending hazard, fetal damage in pregnant women, physical inability to exit the spa or hot tub, and unconsciousness resulting in the danger of drowning. WARNING: The use of alcohol, drugs, or medication can greatly increase the risk of fatal hyperthermia. WARNING: Water attracts children; Always attach a spa cover after each use. WARNING: TO REDUCE THE RISK OF INJURY: Never add water that is higher than 104°F (40°C) into the spa. CONSULT YOUR PHYSICIAN FOR RECOMMENDATIONS. CAUTION: We strongly recommend not to unfold and inflate the spa if the ambient temperature is below 59°F(15°C). We suggest inflating …
Text truncated - open the document above for the full version.
Rev 1/26/2023 Bestway (Hong Kong) International Ltd. Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: 4/25/2024 Ref: Attestation Statements Part 2.911(d)(7) Filing FCC ID or Grantee Code: 2AS3R-400205R Applicant FRN: 0028407294 Bestway (Hong Kong) International Ltd. (“the applicant”) certifies that, as of the date of the filing of the application, Bestway (USA) Inc. is our designated U.S. agent for service of process for the above referenced FCC ID. Bestway (Hong Kong) International Ltd. accepts to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any Commission-related proceeding involving the equipment. Bestway (USA) Inc. accepts, as of the date of the filing of the application, the obligation of the designated U.S. agent for service of process for the above referenced FCC ID. Designated U.S. Agent Information: Name: Bestway (USA) Inc. U.S. Agent FRN: The agent for service of process does no other business with the FCC and does not have an FRN. Address: 3435 S. McQueen Road, Chandler, AZ 85286, United States of America Contact Person: Brannon Smith Tel.: 832-916-1800 Email: [email protected] Sincerely, Bestway (Hong Kong) International Ltd. Bestway (USA) Inc. Mi Huang Brannon Smith [Insert Applicant signature]: [U.S. Agent signature]:
Rev 1/26/2023 Bestway (Hong Kong) International Ltd. Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: 4/25/2024 Ref: Attestation Statements Part 2.911(d)(5)(i) Filing FCC ID: 2AS3R-400205R [Bestway (Hong Kong) International Ltd.] (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. Sincerely, (Applicant signature) Mi Huang (Applicant printed name) Rev 1/26/2023 Bestway (Hong Kong) International Ltd. Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: 4/25/2024 Ref: Attestation Statements Part 2.911(d)(5)(ii) Filing FCC ID: 2AS3R-400205R [Bestway (Hong Kong) International Ltd.] (“the applicant”) certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List (as a specifically named entity or any of its subsidiaries or affiliates) as an entity producing “covered” equipment. Sincerely, (Applicant signature) Mi Huang (Applicant printed name)
Bestway (Hong Kong) International Ltd. Declaration Letter We Bestway (Hong Kong) International Ltd. Hereby declares that the product Electric Spas/Model: S400204, S400205, the versions of the product available for import and sale in the US and Canada, or any units marked with the FCC ID or IC certification number, will not operation on channel 12 and 13. It will not be possible for users and configure these channels in the US and Canada version. Installation of this product must comply with local regulations and codes. During deployment of the system and its initial setup, professional installer must ensure that the allowed EIRP limit is not exceeded (in the Country of exploitation of this equipment). Date: June 28, 2024 __________ Name / Title Mi Huang / Compliance Manager Company: Bestway (Hong Kong) International Ltd. Tel: +86 021-69133312 Email: [email protected]
Bestway (Hong Kong) International Ltd. Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Date: 4/25/2024 SUBJECT: FCC Application for FCC ID: 2AS3R-400205R To Whom It May Concern: We, the undersigned, hereby authorize Scout Gong, Intertek Testing Service Shanghai on our behalf, to apply to the Federal Communications Commission on our equipment. Any and all acts carried out by Scout Gong, Intertek Testing Service Shanghai on our behalf shall have the same effect as acts of our own. This is to advise that we are in full compliance with the Anti- Drug Abuse Act. We, the applicant, are not subject to a denial of federal benefits pursuant to Section 5301 of the Anti-Drug Act of 1988, 21 USC853a, and no party to the application is subject to a denial of federal benefits pursuant to that section. Regards, By: Mi Huang (Signature 1 ) (Print name) Title: Compliance Manager On behalf of: Bestway (Hong Kong) International Ltd. (Company Name) Telephone: 0 21 69133312 (Must be signed by the person that is listed on the FCC Website)
Bestway (Hong Kong) International Ltd. Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Date: 4/25/2024 SUBJECT: 2AS3R-400205R To Whom It May Concern: I, the undersigned, hereby states this equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules, and will apply the Supplier's Declaration of Conformity procedure to the class B computer peripheral portion of this composite device. I understand the following FCC requirements: 1. Devices subject to the SDoC procedure are required to be tested to show compliance with the FCC technical regulations by a recognized accredited testing laboratory. The testing laboratory must be accredited by a Commission approved accreditation body or designated under the terms of a government-to-government Mutual Recognition Agreement (MRA). A listing of those accredited testing laboratories that have been recognized by the Commission is published on the FCC Webpage: https://apps.fcc.gov/oetcf/eas/reports/TestFirmSearch.cfm (Select the "accredited" option to search for FCC recognized accredited test firms.) 2. Pt 2.1077 contains the list of information that must be included in the Supplier's Declaration of Conformity, which must be supplied with each product sold. The SDoC compliance info shall be included in the User’s Manual or as a separate sheet. The info must contain the name, address, and phone number of the responsible party, which must be located within the United States. According to 2.909(b), the responsible party is either the Manufacturer or if the product is imported the Importer. Regards, Applicant Name: Bestway (Hong Kong) International Ltd. Signature of the person in charge: Print Name: Mi Huang
Rev 11/20/07 Bestway (Hong Kong) International Ltd. Federal Communications Commission Authorization and Evaluation Division Confidentiality Request regarding application for certification of FCC ID: 2AS3R-400205R. Pursuant to Sections 0.457 and 0.459 of the Commission’s Rules, we hereby request confidential treatment of information accompanying this application as outlined below: Exhibit Type File Name* Block Diagram, Schematics, Operational Description Block Diagram.pdf Schematics.pdf Operational Description.pdf The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these materials may be harmful to the applicant and provide unjustified benefits to its competitors. The applicant understands that pursuant to Section 0.457 of the Rules, disclosure of this application and all accompanying documentation will not be made before the date of the Grant for this application. Pursuant to DA04-1705 June 15, 2004 of the Commission’s public notice, we also request temporary confidential treatment of information accompanying this application as outlined below: Exhibit Type File Name* Sincerely, By: Mi Huang (Signature/Title) (Print name)
Page 1 of 5 External Photos Page 2 of 5 External view Page 3 of 5 Page 4 of 5 Page 5 of 5
Page 1 of 2 Label and Location Page 2 of 2 The Label for FCC: The Label for IC: The location of the label:
Page 1 of 8 Internal Photos Page 2 of 8 Page 3 of 8 Antenna Page 4 of 8 Page 5 of 8 Page 6 of 8 Page 7 of 8 Page 8 of 8 The length of wire antenna
Bestway (Hong Kong) International Ltd. MPE ASSESSMENT REPORT Report Type: FCC MPE assessment report Model: S400205 Report Number: 2405B1801SHA-003 Issue Date: June 6, 2024 DOCUMENT CONTROL NUMBER: TTRFFCCMPE-01_V1 © 2018 Intertek Intertek Testing Services Shanghai Building No.86, 1198 Qinzhou Road (North) Caohejing Development Zone Shanghai 200233, China Telephone: 86 21 6127 8200 www.intertek.com TEST REPORT This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to permit copying or distribution of this report and then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test results in this report are relevant only to the sample tested. This report by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. TTRFFCCMPE-01_V1© 2018 Intertek Page 2 of 9 Report no.: 2405B1801SHA-003 Applicant: Bestway (Hong Kong) International Ltd. SUITE 713, 7/FLOOR, EAST WING, TSIM SHA TSUI CENTRE, 66 MODY ROAD, KOWLOON, HONG KONG Manufacturer: Bestway Inflatables & Material Corp. No. 208 Jin Yuan Wu Road, Shanghai, 201812, China Manufacturing site: Bestway (Nantong) Recreation Corp. No. 8, West Huimin Road, Rugao Economic and Technology Development Zone, Jiangsu, 226503, China FCC ID: 2AS3R-400205R SUMMARY: The equipment complies with the requirements according to the following standard(s) or Specification: KDB447498 D01 General RF Exposure Guidance v06 FCC Part2.1091, FCC Part2.1093 FCC Part1.1307(b) PREPARED BY: REVIEWED BY: Scout Gong Eric Li Project Engineer Reviewer Report No.: 2405B1801SHA-003 TEST REPORT TTRFFCCMPE-01_V1© 2018 Intertek Page 3 of 9 Revision History Report No. Version Description Issued Date 2405B1801SHA-003 Rev. 01 Initial issue of report June 6, 2024 Report No.: 2405B1801SHA-003 TEST REPORT TTRFFCCMPE-01_V1© 2018 Intertek Page 4 of 9 1 General Information 1.1 Description of Equipment Under Test (EUT) Product name: Electric Spas Type/Model: S400205 Description of EUT: EUT is a wireless Electric Spas with BLE and Wi-Fi module. Rating: 110-120 VAC, 60Hz, 12A EUT type: Tabletop Floor standing Brand name: / Software Version: / Hardware Version: / Sample received date: March 30, 2024 Date of test: March 30, 2024, to June 5, 2024 Report No.: 2405B1801SHA-003 TEST REPORT TTRFFCCMPE-01_V1© 2018 Intertek Page 5 of 9 1.2 Technical Specification Wi-Fi: Frequency Band: 2400MHz ~ 2483.5MHz Support Standards: IEEE 802.11b, IEEE 802.11g, IEEE 802.11n(HT20) Type of Modulation: IEEE 802.11b: DSSS (CCK, DQPSK, DBPSK) IEEE 802.11g: OFDM (64-QAM, 16-QAM, QPSK, BPSK) IEEE 802.11n(HT20): OFDM (64-QAM, 16-QAM, QPSK, BPSK) Operating Frequency: 2412MHz to 2462MHz for IEEE 802.11b/g/n(HT20) Channel Number: 11 Channels for 802.11b, 802.11g and 802.11n(HT20) Channel Separation: 5 MHz Bluetooth LE: Frequency Band: 2400MHz ~ 2483.5MHz Support Standards: Bluetooth Low Energy Type of Modulation: GFSK Channel Number: 40 Data Rate: 1Mbps Channel Separation: 2MHz 1.3 Antenna Information No. Antenna Type Gain Note 1 PCB antenna 2 dBi Internal type Report No.: 2405B1801SHA-003 TEST REPORT TTRFFCCMPE-01_V1© 2018 Intertek Page 6 of 9 1.4 Description of Test Facility Name: Intertek Testing Services Shanghai Address: Building 86, No. 1198 Qinzhou Road (North), Shanghai 200233, P.R. China Telephone: 86 21 61278200 Telefax: 86 21 54262353 The test facility is recognized, certified, or accredited by these organizations: CNAS Accreditation Lab Registration No. CNAS L0139 FCC Accredited Lab Designation Number: CN0175 IC Registration Lab CAB identifier.: CN0014 VCCI Registration Lab Member No: 3598 (Registration No.: R-14243, G-10845, C-14723, T- 12252) A2LA Accreditation Lab Certificate Number: 3309.02 Report No.: 2405B1801SHA-003 TEST REPORT TTRFFCCMPE-01_V1© 2018 Intertek Page 7 of 9 2 MPE Assessment Test Result: Pass 2.1 MPE Assessment Limit Mobile device exposure for standalone operations: Frequency range E-field strength (V/m) H-field strength (A/m) B-field (uT) Equivalent plane wave power density S eq (W/m 2 ) 0-1 Hz - 3,2 × 10 4 4 × 10 4 - 1-8 Hz 10 000 3,2 × 10 4 /f 2 4 × 10 4 /f 2 - 8-25 Hz 10 000 4 000/f 5 000/f - 0,025-0,8 kHz 250/f 4/f 5/f - 0,8-3 kHz 250/f 5 6,25 - 3-150 kHz 87 5 6,25 - 0,15-1 MHz 87 0,73/f 0,92/f - 1-10 MHz 87/f 1/2 0,73/f 0,92/f - 10-400 MHz 28 0,073 0,092 2 400-2 000 MHz 1,375 f 1/2 0,0037 f 1/2 0,0046 f 1/2 f/200 2-300 GHz 61 0,16 0,20 10 Mobile device exposure for simultaneous transmission operations: the sum of the MPE ratios for all simultaneously transmitting antennas incorporated in a host device is ≤ 1.0. Report No.: 2405B1801SHA-003 TEST REPORT TTRFFCCMPE-01_V1© 2018 Intertek Page 8 of 9 2.2 Assessment Results Power density (S) is calculated according to the formula: S = PG / (4πR²) Where S = power density in mW/cm² P = Radiated transmit power in mW G = numeric gain of transmit antenna R = distance (cm) As we can see from the test report 2405B1801SHA-001 and 2405B1801SHA-002: The calculations in the table below use the highest gain of antenna for client EUT. These calculations represent the worst case in terms of the exposure levels. Mode Frequency band Peak conducted output power Antenna Gain R S Limits (MHz) (dBm) (dBi) (cm) (mW/cm 2 ) (mW/cm 2 ) Wi-Fi 2400-2483.5 14.64 2 20 0.0092 1 BLE 2400-2483.5 9.86 2 20 0.0031 1 Note: 1 mW/cm2 from 1.310 Table 1 Therefore, the MPE requirement is deemed to be satisfied. Report No.: 2405B1801SHA-003 TEST REPORT TTRFFCCMPE-01_V1© 2018 Intertek Page 9 of 9 …
Text truncated - open the document above for the full version.
Bestway (Hong Kong) International Ltd. RF TEST REPORT Report Type: FCC Part 15.247 & ISED RSS-247 RF report Model: S400204, S400205 Report Number: 2405B1801SHA-002 Issue Date: June 6, 2024 Document Control Number: TTRF15.247-02_V1 © 2018 Intertek Intertek Testing Services Shanghai Building No.86, 1198 Qinzhou Road (North) Caohejing Development Zone Shanghai 200233, China Telephone: 86 21 6127 8200 www.intertek.com TEST REPORT This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to permit copying or distribution of this report and then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test results in this report are relevant only to the sample tested. This report by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. TTRF15.247-02_V1 © 2018 Intertek Page 2 of 45 Report no.: 2405B1801SHA-002 Applicant: Bestway (Hong Kong) International Ltd. SUITE 713, 7/FLOOR, EAST WING, TSIM SHA TSUI CENTRE, 66 MODY ROAD, KOWLOON, HONG KONG Manufacturer: Bestway Inflatables & Material Corp. No. 208 Jin Yuan Wu Road, Shanghai, 201812, China Manufacturing site: Bestway (Nantong) Recreation Corp. No. 8, West Huimin Road, Rugao Economic and Technology Development Zone, Jiangsu, 226503, China FCC ID: 2AS3R-400205R IC: 26017-400204R SUMMARY: The equipment complies with the requirements according to the following standard(s) or Specification: 47CFR Part 15 (2023): Radio Frequency Devices (Subpart C) ANSI C63.10 (2020): American National Standard of Procedures for Compliance Testing of Unlicensed Wireless Devices RSS-247 Issue 3 (August 2023): Digital Transmission Systems (DTSs), Frequency Hopping Systems (FHSs) and Licence-Exempt Local Area Network (LE-LAN) Devices RSS-Gen Issue 5 (February 2021) Amendment 2: General Requirements for Compliance of Radio Apparatus PREPARED BY: REVIEWED BY: Scout Gong Eric Li Project Engineer Reviewer Report No.: 2405B1801SHA-002 TEST REPORT TTRF15.247-02_V1 © 2018 Intertek Page 3 of 45 Content REVISION HISTORY................................................................................................................................................ 5 MEASUREMENT RESULT SUMMARY ..................................................................................................................... 6 1 GENERAL INFORMATION ............................................................................................................................. 7 1.1 DESCRIPTION OF EQUIPMENT UNDER TEST (EUT) ................................................................................................ 7 1.2 TECHNICAL SPECIFICATION ................................................................................................................................ 7 1.3 ANTENNA INFORMATION .................................................................................................................................. 7 1.4 DESCRIPTION OF TEST FACILITY ......................................................................................................................... 8 2 TEST SPECIFICATIONS ................................................................................................................................... 9 2.1 STANDARDS OR SPECIFICATION .......................................................................................................................... 9 2.2 MODE OF OPERATION DURING THE TEST ............................................................................................................ 9 2.3 TEST SOFTWARE LIST ..................................................................................................................................... 10 2.4 TEST PERIPHERALS LIST .................................................................................................................................. 10 2.5 TEST ENVIRONMENT CONDITION: .................................................................................................................... 10 2.6 INSTRUMENT LIST ......................................................................................................................................... 11 2.7 MEASUREMENT UNCERTAINTY ........................................................................................................................ 12 3 MINIMUM 6DB BANDWIDTH ..................................................................................................................... 13 3.1 LIMIT ......................................................................................................................................................... 13 3.2 MEASUREMENT PROCEDURE .......................................................................................................................... 13 3.3 TEST CONFIGURATION ................................................................................................................................... 13 3.4 TEST RESULTS OF MINIMUM 6DB BANDWIDTH .................................................................................................. 13 4 MAXIMUM CONDUCTED OUTPUT POWER AND E.I.R.P. ............................................................................. 14 4.1 LIMIT ......................................................................................................................................................... 14 4.2 MEASUREMENT PROCEDURE ..........................................…
Text truncated - open the document above for the full version.
Bestway (Hong Kong) International Ltd. RF TEST REPORT Report Type: FCC Part 15.247 & ISED RSS-247 RF report Model: S400204, S400205 Report Number: 2405B1801SHA-001 Issue Date: June 6, 2024 Document Control Number: TTRF15.247-03_V1 © 2018 Intertek Intertek Testing Services Shanghai Building No.86, 1198 Qinzhou Road (North) Caohejing Development Zone Shanghai 200233, China Telephone: 86 21 6127 8200 www.intertek.com TEST REPORT This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to permit copying or distribution of this report and then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test results in this report are relevant only to the sample tested. This report by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. TTRF15.247-03_V1 © 2018 Intertek Page 2 of 69 Report no. 2405B1801SHA-001 Applicant: Bestway (Hong Kong) International Ltd. SUITE 713, 7/FLOOR, EAST WING, TSIM SHA TSUI CENTRE, 66 MODY ROAD, KOWLOON, HONG KONG Manufacturer: Bestway Inflatables & Material Corp. No. 208 Jin Yuan Wu Road, Shanghai, 201812, China Manufacturing site: Bestway (Nantong) Recreation Corp. No. 8, West Huimin Road, Rugao Economic and Technology Development Zone, Jiangsu, 226503, China FCC ID: 2AS3R-400205R IC: 26017-400204R SUMMARY: The equipment complies with the requirements according to the following standard(s) or Specification: 47CFR Part 15 (2023): Radio Frequency Devices (Subpart C) ANSI C63.10 (2020): American National Standard of Procedures for Compliance Testing of Unlicensed Wireless Devices RSS-247 Issue 3 (August 2023): Digital Transmission Systems (DTSs), Frequency Hopping Systems (FHSs) and Licence-Exempt Local Area Network (LE-LAN) Devices RSS-Gen Issue 5 (February 2021) Amendment 2: General Requirements for Compliance of Radio Apparatus PREPARED BY: REVIEWED BY: Scout Gong Eric Li Project Engineer Reviewer Report No.: 2405B1801SHA-001 TEST REPORT TTRF15.247-03_V1 © 2018 Intertek Page 3 of 69 Content REVISION HISTORY................................................................................................................................................ 5 MEASUREMENT RESULT SUMMARY ..................................................................................................................... 6 1 GENERAL INFORMATION ............................................................................................................................. 7 1.1 DESCRIPTION OF EQUIPMENT UNDER TEST (EUT) ................................................................................................ 7 1.2 TECHNICAL SPECIFICATION ................................................................................................................................ 8 1.3 ANTENNA INFORMATION .................................................................................................................................. 8 1.4 DESCRIPTION OF TEST FACILITY .......................................................................................................................... 9 2 TEST SPECIFICATIONS ................................................................................................................................. 10 2.1 STANDARDS OR SPECIFICATION ........................................................................................................................ 10 2.2 MODE OF OPERATION DURING THE TEST ...................................................…
Text truncated - open the document above for the full version.
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 2 | 15C | 2.40 GHz - 2.48 GHz | 9.70 mW |

Electric Spas
Equipment Class
DTS - Digital Transmission System
Electric Spas
Equipment Class
DTS - Digital Transmission System
Electric Spas
Equipment Class
DTS - Digital Transmission System
SPA
Equipment Class
DTS - Digital Transmission System
SPA
Equipment Class
DTS - Digital Transmission System