Application Details

Equipment Class
NII - Unlicensed National Information Infrastructure TX
Date of Grant
Jul 06, 2026
Application Purpose
Original Equipment
Equipment Note
projector
Frequency Range
5745.00000000 - 5825.00000000
Company
Oley company limited
Country
China

Documents & Files

Select a file to view

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗
↗
↗

ID Label/Location Info

↗

RF Exposure Info

↗

Test Report

↗
↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Attestation Statements

Rev1/26/2023 Oleycompanylimited FederalCommunicationsCommission AuthorizationandEvaluationDivision 7435OaklandMillsRoad Columbia,MD21046 USA Date:06-26-2026 Ref:AttestationStatementsPart2.911(d)(5)(i)Filing FCCID:2AS7X-GO2MINI (“Oleycompanylimited”)certifiesthattheequipmentforwhichauthorizationissoughtisnot“covered” equipmentprohibitedfromreceivinganequipmentauthorizationpursuanttosection2.903oftheFCC rules. (“Oleycompanylimited”)certifiesthattheequipmentforwhichauthorizationissoughtdoesnotinclude cybersecurityoranti-virussoftwareproducedorprovidedbyKasperskyLab,Inc.oranyofitssuccessors andassignees,includingequipmentwithintegratedKasperskyLab,Inc.(oranyofitssuccessorsand assignees)cybersecurityoranti-virussoftwarepursuanttoDA-24-886andKDB986446D01Covered EquipmentGuidancesectionB(2a). Deviceisinherentlycompliantbasedonhardwarelimitationsorsoftwarecontrols. or ASoftwareBillofMaterials(SBOM)isprovidedtotheTCBforreview,and Theend-userorthirdpartiescannotinstalladditionalsoftwareonthisdevice. Sincerely, (Applicantsignature)SNOWWANG (Applicantprintedname) Rev1/26/2023 Oleycompanylimited FederalCommunicationsCommission AuthorizationandEvaluationDivision 7435OaklandMillsRoad Columbia,MD21046 USA Date:06-26-2026 Ref:AttestationStatementsPart2.911(d)(5)(ii)Filing FCCID:2AS7X-GO2MINI (“Oleycompanylimited”)certifiesthat,asofthedateofthefilingoftheapplication,Oleycompany limitedisnotidentifiedontheCoveredList(asaspecificallynamedentityoranyofitssubsidiariesor affiliates)asanentityproducing“covered”equipment. Sincerely, (Applicantsignature) (Applicantprintedname)SNOWWANG

Attestation Statements

Oleycompanylimited 2.911(d)(7)USAAgentv1.4 Section2.911(d)(7)USAAgentforServiceofProcess Companyname:Oleycompanylimited Address:3rdFloor,BuildingH,WandaindustrialPark,ZhouShiroad,ShiYan Street,Bao’Andistrict,ShenZhenCity,GuangDongProvince,China.. ProductName:projector FCCID:2AS7X-GO2MINI Model(s):GO2Mini,GO2Air,GO3,GO3Pro,GO5,G05AIR,G06PRO,G08,G08 AIR,P8,BL350,U7,U8,U9,U15,U17,U41,U20,U58,L7,L8,L9,L15,L17,L18, L41,L20,L58,Q20,Q41,Q58,K80,K90,K80Pro,K90Pro 2.911(d)(7)USADesignatedAgentforServiceofProcess We,[Oleycompanylimited](“theapplicant”)designate[CELLTINC.] NOTE1 forthe purposeofacceptingserviceofprocessonbehalfoftheapplicant. Applicantconsent:WeAcknowledgeourconsenttoacceptserviceofprocessinthe UnitedStatesformattersrelatedtotheapplicableequipment,andatthephysicalU.S. addressandemailaddressofthedesignatedagentandacknowledgeour acceptanceofourobligationtomaintainanagentforserviceofprocessintheUnited Statesfornolessthanoneyearaftereitherthegranteehaspermanentlyterminated allmarketingandimportationoftheapplicableequipmentwithintheU.S.,orthe conclusionofanyCommission-relatedadministrativeorjudicialproceedinginvolving theequipment,whicheverislater. Agentobligation:WeAcknowledgeourobligationtoacceptserviceofprocessinthe UnitedStatesformattersrelatedtotheapplicableequipmentatourphysicalU.S. addressandemailaddressfornolessthanoneyearaftereitherthegranteehas permanentlyterminatedallmarketingandimportationoftheapplicableequipment withintheU.S.,ortheconclusionofanyCommission-relatedadministrativeorjudicial proceedinginvolvingtheequipment,whicheverislater. USAAgent Companyname:CELLTINC. Address:140121STST#12958 SACRAMENTO,CA95811,USA FRN:0036412567 Applicant Companyname:Oleycompanylimited Address:3rdFloor,BuildingH,Wanda industrialPark,ZhouShiroad,ShiYan Street,Bao’Andistrict,ShenZhen City,GuangDongProvince,China. Oleycompanylimited 2.911(d)(7)USAAgentv1.4 ContactName:ThompsonLim TelephoneNo:001-424-3474188 Email:[email protected] FRN:0028449221 FCCGranteeCode:2AS7X ContactName:SNOWWANG TelephoneNo:+86-755-27796063 Email:[email protected] Signature: Title:GeneralManager Signature: Title:Manager Date:2026.07.03Date:2026.07.03 NOTE1:AnapplicantlocatedintheUnitedStatesmaydesignateitselfastheagentforservice ofprocess. Reference;FederalRegisterdocument2022-28263publishedon02/06/23 https://www.federalregister.gov/documents/2023/02/06/2022-28263/protecting-against-nation al-security-threats-to-the-communications-supply-chain-through-the

Cover Letter(s)

Oleycompanylimited Date : 06-26-2026 Product/ModelNumber:projector/GO2Mini,GO2Air,GO3,GO3Pro, GO5,G05AIR,G06PRO,G08,G08AIR,P8,BL350,U7,U8,U9,U15,U17, U41,U20,U58,L7,L8,L9,L15,L17,L18,L41,L20,L58,Q20,Q41,Q58, K80,K90,K80Pro,K90Pro FCCID:2AS7X-GO2MINI Towhomitmayconcern, Re:ProductCertificationRepresentativeAuthorizationLetter WeauthorizeQAILaboratoriesLtd.3980NorthFraserWay,BurnabyB.C. CanadaV5J5K5toactonourbehalfonallmattersconcerningtheabove namedequipment. Thisshallincludethefollowing: ď‚·Testing ď‚·Approvalapplicationsandprocedures WedeclarethatQAILaboratoriesLtd.isallowedtoforwardallinformation relatedtotheapprovalprojecttotheappliedcertificationbodyandtothe notificationentitiesandtodiscussanyissuesconcerningtheapproval application.AnyandallactscarriedoutbyQAILaboratoriesLtd.onour behalfshallhavethesameeffectasactsofourown. By:SNOWWANG ContactListedonFCCWesbite Title:Manager Email:[email protected] Telephone:+86-755-27796063 Onbehalfof:Oleycompanylimited

Cover Letter(s)

Oleycompanylimited OfficeofEngineeringTechnology FederalCommunicationsCommission 7435OaklandMillsRoad Columbia,MD21046 USA Date:June26,2026 Subject;RequestforConfidentiality FCCID:2AS7X-GO2MINI ToWhomItMayConcern, PursuanttotheprovisionsoftheCommission’srulesTitle47Sections§0.457and§0.459,we arerequestingtheCommissiontowithholdthefollowingattachment(s)asconfidential documentsfrompublicdisclosureindefinitely. Thesedocumentscontaindetailedsystemandequipmentdescriptionsandareconsideredas proprietaryinformationinoperationoftheequipment.Thepublicdisclosureofthese documentsmightbeharmfultoourcompanyandwouldgivecompetitorsanunfairadvantage inthemarket. SchematicDiagram BlockDiagram PartsList OperationalDescription Tune-upProcedure SoftwareSecurityRequirementsforUNIIdevices Inadditionaltoabovementioneddocuments,inordertocomplywiththemarketingregulations inTitle47CFR§2.803andtheimportationrulesinTitle47CFR§2.1204,whileensuringthat businesssensitiveinformationremainsconfidentialuntiltheactualmarketingofnewly authorizeddevices,werequestShortTermConfidentialityofthefollowingattachment(s); ExternalPhotos TestSetupPhotos InternalPhotos UserManual For45days,pursuanttoPublicNoticeDA04-1705. OR For180dayspursuanttoKDB726920D01. Itisourunderstandingthatallmeasurementtestreports,FCCIDlabelformatand correspondenceduringthecertificationreviewprocesscannotbegrantedasconfidential documentsandthisinformationwillbeavailableforpublicreviewoncethegrantofequipment authorizationisissued. Sincerely, Signature: Name:SNOWWANG Title:Manager

Cover Letter(s)

Oleycompanylimited ProductSimilarityDeclaration Productname: projector Modelname:GO2Mini,GO2Air,GO3,GO3Pro,GO5,G05AIR,G06 PRO,G08,G08AIR,P8,BL350,U7,U8,U9,U15,U17,U41,U20, U58,L7,L8,L9,L15,L17,L18,L41,L20,L58,Q20,Q41,Q58,K80, K90,K80Pro,K90Pro FCCID:2AS7X-GO2MINI We(Oleycompanylimited)herebystatethatallthemodelsare electricalidenticalincludingthesamesoftwareparameterand hardwaredesign(i.e.,circuitdesign,PCBLayout,RF module/circuit,antennatype(s)andantennalocation,components onPCB,etc.,),samemechanicalstructureanddesign(including productenclosure,materials,etc.,),theonlydifferenceisthe modelnumberandcolor. Signature: Name:SNOWWANG Title:Manager Place,date:ShenZhen,2026.06.26

Cover Letter(s)

Oleycompanylimited FCCSoftwareConfigurationControlDeclaration Date:June26,2026 FederalCommunicationsCommission 7435OaklandMillsRoad Columbia,MD21046 USA Attn:OETDept. Product/ModelNumber:projector/GO2Mini,GO2Air,GO3,GO3Pro, GO5,G05AIR,G06PRO,G08,G08AIR,P8,BL350,U7,U8,U9,U15,U17, U41,U20,U58,L7,L8,L9,L15,L17,L18,L41,L20,L58,Q20,Q41,Q58, K80,K90,K80Pro,K90Pro RegardingFCCCountryCodeSelectionguidelinesidentifiedinKDB594280. “Allapplicationsforequipmentauthorizationfortransmittersthatcanhave radioparameters,orothertechnicalparameters,reportedtotheCommission setbysoftwaremusthaveanattestationindicatingthatnothirdpartywillhave software,orconfigurationcontrol,toprogramthedeviceoutofcomplianceof thetechnicalrulesunderwhichithasbeencertified.” Wedeclarethatnothirdpartywillhavesoftware,orconfigurationcontrol,toprogram thedeviceoutofcomplianceofthetechnicalrulesunderwhichithasbeencertified. Name:SNOWWANGDate:June26,2026 Title:Manger Signatureofapplicant :

ID Label/Location Info

Label: projector Model:GO2Mini FCCID:2AS7X-GO2MINI 45mm 30mm

RF Exposure Info

FCCID:2AS7X-GO2MINI RFExposureEvaluation AccordingtoKDB447498D01GeneralRFExposureGuidancev06andpart2.1091,Unlessspecifically requiredbythepublishedRFexposureKDBprocedures,standalone1-gheadorbodyand10-gextremity SARevaluationforgeneralpopulationexposureconditions,bymeasurementornumericalsimulation,isnot requiredwhenthecorrespondingSARTestExclusionThresholdcondition(s),listedbelow,is(are)satisfied. Limits Thecriterialistedinthefollowingtableshallbeusedtoevaluatetheenvironmentimpactofhumanexposure toradiofrequency(RF)radiationasspecifiedin1.1307(b) LimitsforMaximumPermissibleExposure(MPE) Frequencyrange (MHz) Electricfield strength (V/m) Magneticfieldstrength (A/m) Powerdensity (mW/cm 2 ) Averagingtime (minutes) (A)LimitsforOccupational/ControlledExposures 0.3–3.06141.63*(100)6 3.0–301842/f4.89/f*(900/f 2 )6 30–30061.40.1631.06 300–1500f/3006 1500–100,00056 (B)LimitsforGeneralPopulation/UncontrolledExposure 0.3–1.346141.63*(100)30 1.34–30824/f2.19/f*(180/f 2 )30 30–30027.50.0730.230 300–1500f/150030 1500–100,0001.030 f=frequencyinMHz Friistransmissionformula:Pd=(Pout*G)/(4*pi*r 2 ) Where Pd=powerdensityinmW/cm 2 ,Pout=outputpowertoantennainmW; G=gainofantennainlinearscale,Pi=3.1416; R=distancebetweenobservationpointandcenteroftheradiatorincm PdidthelimitofMPE,1mW/cm 2 .Ifweknowthemaximumgainoftheantennaandthetotalpowerinputto theantenna,throughthecalculation,wewillknowthedistancerwheretheMPElimitisreached. TestProcedure SoftwareprovidedbyclientenabledtheEUTtotransmitandreceivedataatlowest,middleandhighest channelindividually. TestResultofRFExposureEvaluation Remark: 1.Wifi2.4gandwifi5.8gdonottransmitatthesametime BTandwificantransmitatthesametime 2.InthecaseofsimultaneouslaunchesforwifiandBT: TheMaxCalc.Thresholds:BT:0.000701,Wifi:0.008825 BTandWifi:0.000701+0.008825=0.009526≤1 SoaSARtestisnotrequired Operating Mode Frequency Measured Power Tuneup tolerance Max.Tune upPower Antenna Gain Power Densityat R=20cm Power Density Limit Result (MHz)(dBm)(dBm)(dBm)(dBi)(mW/cm 2 )(mW/cm 2 ) BT(BR+EDR)2402-2480-0.9 0±1 1.04.470.0007011.0PASS WiFi2.4G2412-246211.07 11±1 124.470.0088251.0PASS WiFi5.8G5745-58255.22 5±1 64.630.0023001.0PASS

Test Report

Report No.:SZNTT26021762E1-3 SZNTT-TR728-0Page1of70 RF Test Data Duty Cycle........................................................................................................................................................................2 Maximum Conducted Output Power..............................................................................................................................12 -6dB Bandwidth..............................................................................................................................................................13 Occupied Channel Bandwidth........................................................................................................................................23 Maximum Power Spectral Density Level....................................................................................................................... 33 Band Edge......................................................................................................................................................................43 Frequency Stability.........................................................................................................................................................51 Conducted RF Spurious Emission.................................................................................................................................61 Report No.:SZNTT26021762E1-3 SZNTT-TR728-0Page2of70 Duty Cycle ConditionModeFrequency(MHz)AntennaDutyCycle(%)CorrectionFactor(dB)1/T(kHz) NVNTa5745Ant157.142.438.33 NVNTa5785Ant157.142.438.33 NVNTa5825Ant157.142.438.33 NVNTn205745Ant1552.69.09 NVNTn205785Ant1552.69.09 NVNTn205825Ant157.142.438.33 NVNTn405755Ant143.753.5914.29 NVNTn405795Ant147.063.2712.5 NVNT ac205745Ant157.142.438.33 NVNT ac205785Ant159.092.287.69 NVNT ac205825Ant159.092.287.69 NVNT ac405755Ant147.063.2712.5 NVNT ac405795Ant1503.0111.11 NVNT ax205745Ant152.382.819.09 NVNT ax205785Ant157.142.438.33 NVNT ax205825Ant1552.69.09 NVNT ax405755Ant143.753.5914.29 NVNT ax405795Ant147.063.2712.5 Report No.:SZNTT26021762E1-3 SZNTT-TR728-0Page3of70 Duty Cycle NVNT a 5745MHz Ant1 Duty Cycle NVNT a 5785MHz Ant1 Report No.:SZNTT26021762E1-3 SZNTT-TR728-0Page4of70 Duty Cycle NVNT a 5825MHz Ant1 Duty Cycle NVNT n20 5745MHz Ant1 Report No.:SZNTT26021762E1-3 SZNTT-TR728-0Page5of70 Duty Cycle NVNT n20 5785MHz Ant1 Duty Cycle NVNT n20 5825MHz Ant1 Report No.:SZNTT26021762E1-3 SZNTT-TR728-0Page6of70 Duty Cycle NVNT n40 5755MHz Ant1 Duty Cycle NVNT n40 5795MHz Ant1 Report No.:SZNTT26021762E1-3 SZNTT-TR728-0Page7of70 Duty Cycle NVNT ac20 5745MHz Ant1 Duty Cycle NVNT ac20 5785MHz Ant1 Report No.:SZNTT26021762E1-3 SZNTT-TR728-0Page8of70 Duty Cycle NVNT ac20 5825MHz Ant1 Duty Cycle NVNT ac40 5755MHz Ant1 Report No.:SZNTT26021762E1-3 SZNTT-TR728-0Page9of70 Duty Cycle NVNT ac40 5795MHz Ant1 Duty Cycle NVNT ax20 5745MHz Ant1 Report No.:SZNTT26021762E1-3 SZNTT-TR728-0Page10of70 Duty Cycle NVNT ax20 5785MHz Ant1 Duty Cycle NVNT ax20 5825MHz Ant1 Report No.:SZNTT26021762E1-3 SZNTT-TR728-0Page11of70 Duty Cycle NVNT ax40 5755MHz Ant1 Duty Cycle NVNT ax40 5795MHz Ant1 Report No.:SZNTT26021762E1-3 SZNTT-TR728-0Page12of70 Maximum Conducted Output Power ConditionModeFrequency (MHz) AntennaConducted Power(dBm) Conducted Power(W) Limit Conducted(dBm) Verdict NVNTa5745Ant11.850.0015330Pass NVNTa5785Ant11.340.0013630Pass NVNTa5825Ant11.240.0013330Pass NVNT n205745Ant11.900.0015530Pass NVNT n205785Ant11.210.0013230Pass NVNT n205825Ant11.110.0012930Pass NVNT n405755Ant13.780.0023930Pass NVNT n405795Ant13.400.0021930Pass NVNT ac205745Ant15.220.0033330Pass NVNT ac205785Ant14.710.0029630Pass NVNT ac205825Ant13.840.0024230Pass NVNT ac405755Ant13.980.002530Pass NVNT ac405795Ant13.580.0022830Pass NVNT ax205745Ant14.790.0030130Pass NVNT ax205785Ant13.940.0024830Pass NVNT ax205825Ant14.470.002830Pass NVNT ax405755Ant14.180.0026230Pass NVNT ax405795Ant13.890.0024530Pass Report No.:SZNTT26021762E1-3 SZNTT-TR728-0Page13of70 -6dB Bandwidth ConditionModeFrequency (MHz) Antenna-6dBBandwidth (MHz) Limit-6dBBandwidth (MHz) Verdict NVNTa5745Ant116.330.5Pass NVNTa5785Ant116.340.5Pass NVNTa5825Ant116.320.5Pass NVNT n205745Ant117.270.5Pass NVNT n205785Ant117.290.5Pass NVNT n205825Ant117.410.5Pass NVNT n405755Ant135.370.5Pass NVNT n405795Ant135.70.5Pass NVNT ac205745Ant117.220.5Pass NVNT ac205785Ant117.110.5Pass NVNT ac205825Ant117.260.5Pass NVNT ac405755Ant135.360.5Pass NVNT ac405795Ant135.530.5Pass NVNT ax205745Ant117.270.5Pass NVNT ax205785Ant117.110.5Pass NVNT ax205825Ant117.140.5Pass NVNT ax405755Ant135.510.5Pass NVNT ax405795Ant135.440.5Pass Report No.:SZNTT26021762E1-3 SZNTT-TR728-0Page14of70 -6dB Bandwidth NVNT a 5745MHz Ant1 -6dB Bandwidth NVNT a 5785MHz Ant1 Report No.:SZNTT26021762E1-3 SZNTT-TR728-0Page15of70 -6dB Bandwidth NVNT a 5825MHz Ant1 -6dB Bandwidth NVNT n20 5745MHz Ant1 Report No.:SZNTT26021762E1-3 SZNTT-TR728-0Page16of70 -6dB Bandwidth NVNT n20 5785MHz Ant1 -6dB Bandwidth NVNT n20 5825MHz Ant1 Report No.:SZNTT26021762E1-3 SZNTT-TR728-0Page17of70 -6dB Bandwidth NVNT n40 5755MHz Ant1 -6dB Bandwidth NVNT n40 5795MHz Ant1 Report No.:SZNTT26021762E1-3 SZNTT-TR728-0Page18of70 -6dB Bandwidth NVNT ac20 5745MHz Ant1 -6dB Bandwidth NVNT ac20 5785MHz Ant1 Report No.:SZNTT26021762E1-3 SZNTT-TR728-0Page19of70 -6dB Bandwidth NVNT ac20 5825MHz Ant1 -6dB Bandwidth NVNT ac40 5755MHz Ant1 Report No.:SZNTT26021762E1-3 SZNTT-TR728-0Page20of70 -6dB Bandwidth NVNT ac40 5795MHz Ant1 -6dB Bandwidth NVNT ax20 5745MHz Ant1 Report No.:SZNTT26021762E1-3 SZNTT-TR728-0Page21of70 -6dB Bandwidth NVNT ax20 5785MHz Ant1 -6dB Bandwidth NVNT ax20 5825MHz Ant1 Report No.:SZNTT26021762E1-3 SZNTT-TR728-0Page22of70 -6dB Bandwidth NVNT ax40 5755MHz Ant1 -6dB Bandwidth NVNT ax40 5795MHz Ant1 Report No.:SZNTT26021762E1-3 SZNTT-TR728-0Page23of70 Occupied Channel Bandwidth ConditionModeFrequency(MHz)Antenna99%OBW(MHz) NVNTa5745Ant116.478 NVNTa5785Ant116.472 NVNTa5825Ant116.492 NVNTn205745Ant117.579 NVNTn205785Ant117.…

Text truncated - open the document above for the full version.

Test Report

SZNTT-TR833-0Page 1 of 45 Hotline:0755-27889935http://www.ntt-testing.com TESTREPORT FCCID:2AS7X-GO2MINI Product:projector ModelName: GO2Mini,GO2Air,GO3,GO3Pro,GO5,G05AIR,G06 PRO,G08,G08AIR,P8,BL350,U7,U8,U9,U15,U17, U41,U20,U58,L7,L8,L9,L15,L17,L18,L41,L20,L58, Q20,Q41,Q58,K80,K90,K80Pro,K90Pro Brand:N/A ReportNo.: SZNTT26021762E1-3 Preparedfor Oleycompanylimited 3rdFloor,BuildingH,WandaindustrialPark,ZhouShiroad,ShiYanStreet,Bao’An district,ShenZhenCity,GuangDongProvince,China. Preparedby ShenzhenNTTTestingTechnologyCo.,Ltd. 1B,Building2,FactoryBuilding&103,Building3,FactoryBuilding,Dayang IndustrialParkNo.4,IndustrialAvenue,TangweiCommunity,FuhaiSub- district,Bao'anDistrict,ShenzhenCity,China TEL: 0755-27889935 ReportNo.:SZNTT26021762E1-3 SZNTT-TR833-0Page 2 of 45 Hotline:0755-27889935http://www.ntt-testing.com 1TESTRESULTCERTIFICATION Applicant:Oleycompanylimited Address: 3 rd Floor,BuildingH,WandaindustrialPark,ZhouShiroad,ShiYanStreet,Bao’An district,ShenZhenCity,GuangDongProvince,China. Manufacturer:Oleycompanylimited Address: 3 rd Floor,BuildingH,WandaindustrialPark,ZhouShiroad,ShiYanStreet,Bao’An district,ShenZhenCity,GuangDongProvince,China. Productname:projector Modelname:GO2Mini Additionalmodel: GO2Air,GO3,GO3Pro,GO5,G05AIR,G06PRO,G08,G08AIR,P8,BL350,U7, U8,U9,U15,U17,U41,U20,U58,L7,L8,L9,L15,L17,L18,L41,L20,L58,Q20, Q41,Q58,K80,K90,K80Pro,K90Pro Standards:FCCCFR47Part15Section15.247 Testprocedure: ANSIC63.10-2020+Cor.1-2023 KDB789033D02GeneralUNIITestProceduresNewRulesv02r01 Dateoftest:May22,2026toJun.12,2026 DateofIssue:Jun.12,2026 ThisdevicedescribedabovehasbeentestedbyNTT,andthetestresultsshowthattheequipmentunder test(EUT)isincompliancewiththeFCCrequirements.Anditisapplicableonlytothetestedsample identifiedinthereport. Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofNTT,thisdocumentmaybe alteredorrevisedbyNTT,personalonly,andshallbenotedintherevisionofthedocument. Preparedby(TestEngineer): CindyQin Reviewer(Supervisor): KenWu Approved(Manager): AbelYu ReportNo.:SZNTT26021762E1-3 SZNTT-TR833-0Page 3 of 45 Hotline:0755-27889935http://www.ntt-testing.com Contents Page 1TESTRESULTCERTIFICATION...............................................................................................................................2 2TESTSUMMARY..........................................................................................................................................................5 3TESTFACILITY.............................................................................................................................................................6 4GENERALINFORMATION..........................................................................................................................................7 4.1GENERALDESCRIPTIONOFE.U.T.....................................................................................................................7 4.2TESTSETUPCONFIGURATION............................................................................................................................8 4.3TESTMODE.........................................................................................................................................................9 5EQUIPMENTDURINGTEST....................................................................................................................................10 5.1EQUIPMENTSLIST.............................................................................................................................................10 5.2MEASUREMENTUNCERTAINTY.........................................................................................................................12 5.3DESCRIPTIONOFSUPPORTUNITS...................................................................................................................12 6CONDUCTEDEMISSION..........................................................................................................................................13 6.1E.U.T.OPERATION............................................................................................................................................13 6.2EUTSETUP.......................................................................................................................................................13 6.3TESTSET-UP(BLOCKDIAGRAMOFCONFIGURATION).................................................................................14 6.4MEASUREMENTPROCEDURE:...........................................................................................................................14 6.5CONDUCTEDEMISSIONLIMIT...........................................................................................................................14 6.6MEASUREMENTDESCRIPTION..........................................................................................................................15 6.7CONDUCTEDEMISSIONTESTRESULT.............................................................................................................15 7RADIATEDSPURIOUSEMISSIONS......................................................................................................................19 7.1EUTOPERATION...............................................................................................................................................20 7.2TESTSETUP......................................................................................................................................................21 7.3SPECTRUMANALYZERSETUP..........................................................................................................................23 7.4TESTPROCEDURE.............................................................................................................................................24 7.5SUMMARYOFTESTRESULTS...........................................................................................................................…

Text truncated - open the document above for the full version.

Contact Information

Applicant

SNOW WANG
[email protected]Fax: +86-755-27901976

Technical Contact

CELLT INC.Thompson Lim
[email protected]

1401 21ST ST# 12958 · United States

Test Firm

Shenzhen NTT Testing Technology Co., Ltd.Henry Wang
[email protected]

Technical Specifications

#Rule PartsFrequency RangePower Output
115E5.75 GHz - 5.83 GHz3.33 mW
Confidentiality
Long Term
Grant Notes
Power listed is the maximum conducted output power. This device contains 20 and 40 MHz signal bandwidth. The antennas used with this transmitter must be installed to provide a minimum separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. End-users must be provided with operating procedures for satisfying RF exposure compliance.

Other Applications from Oley company limited

Projector - FCC ID 2AS7X-BL158 - Oley company limited
2AS7X-BL158

Projector

Jul 22, 2024

Equipment Class

DTS - Digital Transmission System
Projector - FCC ID 2AS7X-F4 - Oley company limited
2AS7X-F4

Projector

Dec 26, 2023

Equipment Class

NII - Unlicensed National Information Infrastructure TX
Projector - FCC ID 2AS7X-W13 - Oley company limited
2AS7X-W13

Projector

Dec 28, 2022

Equipment Class

DTS - Digital Transmission System
projector - FCC ID 2AS7X-X2 - Oley company limited
2AS7X-X2

projector

Jun 01, 2021

Equipment Class

DTS - Digital Transmission System
projector - FCC ID 2AS7X-BL108 - Oley company limited
2AS7X-BL108

projector

Mar 18, 2021

Equipment Class

DTS - Digital Transmission System