User Manual © 2022 Phillips Connect Technologies LLC 1 / 9 Dagger-QG User Manua Dagger QG and Dagger QG Slim 4-8470-10 Tracking Device Author Revision Changes Date Tony_Wang V01 Initial version 2022-01-06 The information presented in this document is strictly confidential and contains trade secrets and other confidential information that are the exclusive property of Phillips Connect Technologies. User Manual © 2022 Phillips Connect Technologies LLC 2 / 9 Contents 1 Introduction 3 2 Hardware Design 4 2.1 Basic Hardware 4 2.2 Basic RF Performance 5 2.3 Certification and Safety 6 3 Test Items 7 3.1 Hardware 7 3.2 Software 7 Mechanical Structure(mm) 8 FCC/IC Statement 9 User Manual © 2022 Phillips Connect Technologies LLC 3 / 9 1 Introduction The Dagger-QG is a self-contained tracking device that combines the GPS with LTE and BLE connectivity. The Dagger-QG is a single endpoint device to a user or a server application. It can be quired, updated and configured either through a serial connection, or an over the air LTE IP- network. The Dagger-QG presents itself over these connections as an enhanced cellular modem with attached functional elements. These elements include: ⚫ GPS location engine ⚫ General Purpose I/O (GPIO) pins ⚫ Serial UART port ⚫ Voltage monitor ⚫ BLE5.0 Application scene: User Manual © 2022 Phillips Connect Technologies LLC 4 / 9 2 Hardware Design 2.1 Basic Hardware Items Requirement Baseband Chipset Qualcomm Cat.M1 RF Transceiver Qualcomm SDR Memory Internal Air Interface Support for LTE Cat.M1 Frequency 4G band support : Band 2/4/5/12/13/25/26 BLE5.0 band support : ISM 2.4GHz Antenna Internal Antenna / Chip Antenna GPS Antenna Dedicated high performance ceramic antenna Interface UART TX UART RX 12V DC Input(1A current) GPI GPO GND Battery Monitor Supported Watchdog Supported Motion Detect Supported LED 2 LEDs (Red and Green) Battery Built in battery(8.8A non-chargeable) Power Cable connector type 6 pin Power Consumption < 5Watts The Dagger-QG provides support for specialized hardware features through AT commands. The features supported include the following. GPS The major functionality of the GPS system is to compute the correlation results between the incoming signal and the selected PRN code based on certain Carrier Doppler Frequency, Code Doppler Frequency, code phase, carrier phase, and the particular satellite the system is tracking or acquiring. GPIO The GPIO pins are presented to the external environment on the main connector. They are general purpose bidirectional lines capable of providing system interrupts to generate a report or drive logic levels to external devices. LEDs Two LED status indicators are provided to verify correct installation (Red) and operation (Green). User Manual © 2022 Phillips Connect Technologies LLC 5 / 9 UART A UART port is provided for AT command and data interaction and optionally for application specific control. Battery Monitor The battery monitor is internal analog input scaled such that the DC value of the power input pin to the Dagger-QG system is measured. Watchdog Qualcomm chipset supports internal software and hardware Watchdog. Motion Detect This function will work with firmware power down options to keep the Dagger-QG in a very low power down state until motion is detected. Upon wakening, a report can then be generated. 2.2 Basic RF Performance Over the Air Requirements Remark TRP free space CTIA TRP free space TIS free space CTIA TIS free space Radio Frequency BLE5.0 Band ISM 2.4GHz Rx Spec Follow Chipset Tx Spec Follow Chipset 4G LTE Cat.M1 Band Band 2/4/5/12/13/25/26 Rx Spec Follow 3gpp TS 36.521 Ch.7 Tx Spec Follow 3gpp TS 36.521 Ch.6 GPS Frequency Support L1-band (1.57542GHz) 2.3 Certification and Safety Items Requirement Drop Design 0.8meter 6 direction standard drop test Temperature Range -20 to 60°C Operation -40 to +85°C Storage Humidity: 20% to 90% Operation 10% to 95% Storage FCC Certification FCC Part 15/22/24/27/90 IC Certification RSS-130/132/133/139/247 ESD Requirement 8KV non-Conductive User Manual © 2022 Phillips Connect Technologies LLC 6 / 9 3 Test Items 3.1 Hardware Test Item Description Function Test • Power Input Test • Heat Dissipation Test • UART Stability Test • GPIO Level Test • LED Stability Test • Drop Down Test • ESD Test • High/Low Temperature Test RF Test • LTE Conformance Test • GPS Performance Test • BLE Performance Test • Antenna Performance Test 3.2 Software Test Environment Construct ➢ UART Test environment 1. Connect Dagger-QG to pc with console board. 2. Open Terminal tool and send the AT command. 3. Response can be shown at terminal window. User Manual © 2022 Phillips Connect Technologies LLC 7 / 9 Mechanical Structure (115*16*92 mm) TOP SIDE BOTTOM FRONT User Manual © 2022 Phillips Connect Technologies LLC 8 / 9 Federal Communication Commission Interference Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures: - Reorient or relocate the receiving antenna. - Increase the separation between the equipment and receiver. - Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. - Consult the dealer or an experienced radio/TV technician for help. This device complies with Part 15 of the FCC Rules. Operation is subject to th…
Text truncated - open the document above for the full version.
PHILLIPS CONNECT TECHNOLOGIES LLC Add: 5231 California Avenue, Suite 110 Irvine California United States Date: 2022-6-28 FCC ID: 2ASKH-DQG01 Dear Sir/Madam, We, PHILLIPS CONNECT TECHNOLOGIES LLC Hereby declares the following statement for Federal Communications Commission, PCB board, circuit, structure and internal of these model(s) are the same, Only model number is different for these model: Product name: Dagger QG and Dagger QG Slim Model no.: 4-8470-10, 4-8490-17, 4-8490-10 Sincerely, Name/Title: Doug Reauso/sales Manager Company: PHILLIPS CONNECT TECHNOLOGIES LLC Address: 5231 California Avenue, Suite 110 Irvine California United States Phone: 17149316998 Fax: 17149316998 E-Mail: [email protected]
CONFIDENTIALITY REQUEST for Certification Service in USA Federal Communication Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21046 Date:<2022-6-28> Pursuant to Paragraphs §0.457 and 0.459 of the Commission’s Rules (47 C.F.R.) and Section §552(b)(4) of the Freedom of Information Act, we requests confidentiality for the following products: FCC ID Model name 2ASKH-DQG01 4-8470-10 For the product stated above, we request that the following information be held confidential; Exhibits Long-Term Confidentiality Short-Term Confidentiality Short-Term Confidentiality Days External Photos Internal Photos Block Diagram Schematics Test Setup Photos User’s Manual Parts List Tune Up Operational Descriptions The long-term confidentiality exhibits contain our trade secrets and proprietary information that could be of benefit to our competitors. The short-term confidentiality on the basis of ensuring that business sensitive information remains confidential until the actual marketing of our new device. If you have any questions, please feel free to contact me at the address shown below. Sincerely, Name/Title: Doug Reauso/sales Manager Company: PHILLIPS CONNECT TECHNOLOGIES LLC Address: 5231 California Avenue, Suite 110 Irvine California United States Phone: 17149316998 Fax: 17149316998 E-Mail: [email protected]
PHILLIPS CONNECT TECHNOLOGIES LLC 5231 California Avenue, Suite 110 Irvine California United States Federal Communications Commission Authorization and Evaluation Division Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MD 21046 2022-6-28 To whom it may concern: We, the undersigned, hereby authorize Eurofins Product Service GmbH to act on our behalf in all matters relating to applications for equipment authorization FCC ID: 2ASKH-DQG01 including the signing of all documents related to these matters. Any and all acts carried out by Eurofins Product Service GmbH on our behalf shall have the same effect as acts of our own. By signing this application form, we agree to Eurofins’ current valid General Terms and Conditions (AGB),Testing and Certification Regulations (PZO) which can be viewed on following website www.eurofins.de/ee or retrieved on request. We also hereby certify that no party to this application is subject to a denial of benefits, including FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 862. Sincerely, Name/Title: Doug Reauso/sales Manager Company: PHILLIPS CONNECT TECHNOLOGIES LLC Address: 5231 California Avenue, Suite 110 Irvine California United States Phone: 17149316998 Fax: 17149316998 E-Mail: [email protected]
Page 1 of 5 FCC ID: 2ASKH-DQG01 IC: 25015-DQG01 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity External Photos of the EUT Fig.1 Fig.2 Page 2 of 5 FCC ID: 2ASKH-DQG01 IC: 25015-DQG01 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig.3 Fig.4 Page 3 of 5 FCC ID: 2ASKH-DQG01 IC: 25015-DQG01 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig.5 Fig.6 Page 4 of 5 FCC ID: 2ASKH-DQG01 IC: 25015-DQG01 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig.7 Fig.8 Page 5 of 5 FCC ID: 2ASKH-DQG01 IC: 25015-DQG01 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig.9
Page1of1FCCID:2ASKH-DQG01IC:25015-DQG01 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity LABELANDLOCATION (Size:L4.0cmx3.0cm) LabelLocation DaggerQGandDaggerQGSlim FCCID:2ASKH-DQG01 IC:25015-DQG01 HVIN:4-8470-10 DaggerQGandDaggerQGSlim FCCID:2ASKH-DQG01 IC:25015-DQG01 HVIN:4-8490-17 DaggerQGandDaggerQGSlim FCCID:2ASKH-DQG01 IC:25015-DQG01 HVIN:4-8490-10
Page 1 of 5 FCC ID: 2ASKH-DQG01 IC: 25015-DQG01 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Internal Photos of the EUT Fig. 1 Fig. 2 Page 2 of 5 FCC ID: 2ASKH-DQG01 IC: 25015-DQG01 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 3 Fig. 4 Page 3 of 5 FCC ID: 2ASKH-DQG01 IC: 25015-DQG01 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 5 Fig. 6 Page 4 of 5 FCC ID: 2ASKH-DQG01 IC: 25015-DQG01 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 7 Fig. 8 LTE ANT GPS RX ANT BLE ANT Page 5 of 5 FCC ID: 2ASKH-DQG01 IC: 25015-DQG01 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 9 Fig. 10
Page 1 of 6 FCC ID: 2ASKH-DQG01 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Maximum Permissible Exposure Report 1. Product Information EUT : Dagger QG and Dagger QG Slim Test Model : 4-8470-10 Additional Model No. : 4-8490-17, 4-8490-10 Model Declaration : PCB board, structure and internal of these model(s) are the same, So no additional models were tested Power Supply : Input: DC 12V DC 3.6V by Battery, 5Ah Hardware Version : 1.3.0 Software Version : APP: 2.10.53_B4 BLE: 1.0.6_B13 BIN: 5.5.9 Bluetooth : Frequency Range : 2402MHz ~ 2480MHz Channel Number : 40 channels for Bluetooth V5.0 (DTS) Channel Spacing : 2MHz for Bluetooth V5.0 (DTS) Modulation Type : GFSK for Bluetooth V5.0 (DTS) Bluetooth Version : V5.0 Antenna Description : Chip Antenna, 3.6dBi(Max.) LTE Cat M1 : Support Band : E-UTRA Band 2(U.S.-Band) E-UTRA Band 4(U.S.-Band) E-UTRA Band 5(U.S.-Band) E-UTRA Band 12(U.S.-Band) E-UTRA Band 13(U.S.-Band) E-UTRA Band 25(U.S.-Band) E-UTRA Band 26(U.S.-Band) LTE Release Version : R14 Type Of Modulation : QPSK/16QAM Antenna Description : Internal Antenna 3.0dBi (max.) For E-UTRA Band 2 3.0dBi (max.) For E-UTRA Band 4 3.0dBi (max.) For E-UTRA Band 5 3.0dBi (max.) For E-UTRA Band 12 3.0dBi (max.) For E-UTRA Band 13 3.0dBi (max.) For E-UTRA Band 25 3.0dBi (max.) For E-UTRA Band 26 Page 2 of 6 FCC ID: 2ASKH-DQG01 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Power Class : Class 3 GPS function : Support and only RX Extreme temp. Tolerance : -30°C to +50°C Extreme vol. Limits : 3.1VDC to 4.2VDC (nominal: 3.6VDC) Exposure category : General population/uncontrolled environment EUT Type : Production Unit Device Type : Mobile Device Page 3 of 6 FCC ID: 2ASKH-DQG01 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity 2. Evaluation Method Systems operating under the provisions of FCC 47 CFR section shall be operated in a manner that ensures that the public is not exposed to radio frequency energy level in excess of the Commission’s guidelines. In accordance with 47 CFR FCC Part 2 Subpart J, section 2.1091 this device has been defined as mobile device whereby a distance of 0.2m normally can be maintained between the user and the device, and below RF Permissible Exposure limit shall comply with. In accordance with KDB447498D01 for Simultaneous transmission MPE test exclusion applies when the sum of the MPE ratios for all simultaneous transmitting antennas incorporated in a host device, based on the calculated/estimated, numerically modelled or measured field strengths or power density, is ≤ 1.0. The MPE ratio of each antenna is determined at the minimum test separation distance required by the operating configurations and exposure conditions of the host device, according to the ratio of field strengths or power density to MPE limit, at the test frequency. Either the maximum peak or spatially averaged results from measurements or numerical simulations may be used to determine the MPE ratios. Spatial averaging does not apply when MPE is estimated using simple calculations based on far-field plane-wave equivalent conditions. The antenna installation and operating requirements for the host device must meet the minimum test separation distances required by all antennas, in both standalone and simultaneous transmission operations, to satisfy compliance. 3. Limit 3. 1 Refer Evaluation Method ANSI C95.1–1999: IEEE Standard for Safety Levels with Respect to Human Exposure to Radio Frequency Electromagnetic Fields, 3 kHz to 300 GHz. FCC KDB publication 447498 D01 General 1 RF Exposure Guidance v06: Mobile and Portable Devices RF Exposure Procedures and Equipment Authorization Policies. FCC CFR 47 part1 1.1310: Radiofrequency radiation exposure limits. FCC CFR 47 part2 2.1091: Radiofrequency radiation exposure evaluation: mobile devices 3. 2 Limit Limits for Maximum Permissible Exposure (MPE)/Controlled Exposure Frequency Range(MHz) Electric Field Strength(V/m) Magnetic Field Strength(A/m) Power Density (mW/cm²) Averaging Time (minute) Limits for Occupational/Controlled Exposure 0.3 – 3.0 3.0 – 30 30 – 300 300 – 1500 1500 – 100,000 614 1842/f 61.4 / / 1.63 4.89/f 0.163 / / (100) * (900/f 2 )* 1.0 f/300 5 6 6 6 6 6 Limits for Maximum Permissible Exposure (MPE)/Uncontrolled Exposure Frequency Range(MHz) Electric Field Strength(V/m) Magnetic Field Strength(A/m) Power Density (mW/cm²) Averaging Time (minute) Limits for Occupational/Controlled Exposure 0.3 – 3.0 3.0 – 30 30 – 300 300 – 1500 1500 – 100,000 614 824/f 27.5 / / 1.63 2.19/f 0.073 / / (100) * (180/f 2 )* 0.2 f/1500 1.0 30 30 30 30 30 F=frequency in MHz *=Plane-wave equivalent power density Page 4 of 6 FCC ID: 2ASKH-DQG01 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity 4. MPE Calculation Method Predication of MPE limit at a given distance Equation from page 18 of OET Bulletin 65, Edition 97-01 S=PG/4πR² Where: S=power density P=power input to antenna G=power gain of the antenna in the direction of interest relative to an isotropic radiator R=distance to the center of radiation of the antenna 5. Antenna I…
Text truncated - open the document above for the full version.
Page 1 of 26 FCC ID: 2ASKH-DQG01 IC: 25015-DQG01 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Appendix A RF Test Data for BLE (Conducted Measurement) Product Name: Dagger QG and Dagger QG Slim Test Model: 4-8470-10 Environmental Conditions Temperature: 23.5 C Relative Humidity: 52.2% ATM Pressure: 100.0 kPa Test Engineer: Ling Zhu Supervised by: Li Huan Page 2 of 26 FCC ID: 2ASKH-DQG01 IC: 25015-DQG01 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity A.1 -6dB Bandwidth Condition Mode Frequency (MHz) Antenna -6 dB Bandwidth (MHz) Limit -6 dB Bandwidth (MHz) Verdict NVNT BLE 1M 2402 Ant1 0.739 0.5 Pass NVNT BLE 1M 2440 Ant1 0.747 0.5 Pass NVNT BLE 1M 2480 Ant1 0.737 0.5 Pass Page 3 of 26 FCC ID: 2ASKH-DQG01 IC: 25015-DQG01 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Test Graphs -6dB Bandwidth NVNT BLE 1M 2402MHz Ant1 -6dB Bandwidth NVNT BLE 1M 2440MHz Ant1 Page 4 of 26 FCC ID: 2ASKH-DQG01 IC: 25015-DQG01 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity -6dB Bandwidth NVNT BLE 1M 2480MHz Ant1 Page 5 of 26 FCC ID: 2ASKH-DQG01 IC: 25015-DQG01 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity A.2 Occupied Channel Bandwidth Condition Mode Frequency (MHz) Antenna 99% OBW (MHz) NVNT BLE 1M 2402 Ant1 1.077 NVNT BLE 1M 2440 Ant1 1.078 NVNT BLE 1M 2480 Ant1 1.067 Page 6 of 26 FCC ID: 2ASKH-DQG01 IC: 25015-DQG01 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Test Graphs OBW NVNT BLE 1M 2402MHz Ant1 OBW NVNT BLE 1M 2440MHz Ant1 Page 7 of 26 FCC ID: 2ASKH-DQG01 IC: 25015-DQG01 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity OBW NVNT BLE 1M 2480MHz Ant1 Page 8 of 26 FCC ID: 2ASKH-DQG01 IC: 25015-DQG01 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity A.3 Maximum Conducted Output Power Condition Mode Frequency (MHz) Antenna Conducted Power (dBm) Limit (dBm) Verdict NVNT BLE 1M 2402 Ant1 0.73 30 Pass NVNT BLE 1M 2440 Ant1 0.9 30 Pass NVNT BLE 1M 2480 Ant1 0.41 30 Pass Page 9 of 26 FCC ID: 2ASKH-DQG01 IC: 25015-DQG01 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Test Graphs Power NVNT BLE 1M 2402MHz Ant1 Power NVNT BLE 1M 2440MHz Ant1 Page 10 of 26 FCC ID: 2ASKH-DQG01 IC: 25015-DQG01 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Power NVNT BLE 1M 2480MHz Ant1 Page 11 of 26 FCC ID: 2ASKH-DQG01 IC: 25015-DQG01 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity A.4 Maximum Power Spectral Density Level Condition Mode Frequency (MHz) Antenna Conducted PSD (dBm/3kHz) Duty Factor (dB) Total PSD (dBm/3kHz) Limit (dBm/3kHz) Verdict NVNT BLE 1M 2402 Ant1 -14.53 0 -14.53 8 Pass NVNT BLE 1M 2440 Ant1 -12.34 0 -12.34 8 Pass NVNT BLE 1M 2480 Ant1 -13.62 0 -13.62 8 Pass Page 12 of 26 FCC ID: 2ASKH-DQG01 IC: 25015-DQG01 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Test Graphs PSD NVNT BLE 1M 2402MHz Ant1 PSD NVNT BLE 1M 2440MHz Ant1 Page 13 of 26 FCC ID: 2ASKH-DQG01 IC: 25015-DQG01 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity PS…
Text truncated - open the document above for the full version.
Page 1 of 33 FCC ID: 2ASKH-DQG01 Report No.: LCS220309059AEA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity FCC TEST REPORT For PHILLIPS CONNECT TECHNOLOGIES LLC Dagger QG and Dagger QG Slim Test Model: 4-8470-10 Additional Model No.: 4-8490-17, 4-8490-10 Prepared for : PHILLIPS CONNECT TECHNOLOGIES LLC Address : 5231 California Avenue, Suite 110, Irvine, CA 92617 Prepared by : Shenzhen LCS Compliance Testing Laboratory Ltd. Address : 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel : (+86)755-82591330 Fax : (+86)755-82591332 Web : www.LCS-cert.com Mail : [email protected] Date of receipt of test sample : March 16, 2022 Number of tested samples : 2 Sample No. : 220309059A-1, 220309059A-2 Serial number : Prototype Date of Test : March 16, 2022 ~ May 05, 2022 Date of Report : May 06, 2022 Page 2 of 33 FCC ID: 2ASKH-DQG01 Report No.: LCS220309059AEA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity FCC TEST REPORT FCC CFR 47 PART 15 C(15.247) Report Reference No. ................. : LCS220309059AEA Date of Issue .................................. : May 06, 2022 Testing Laboratory Name ............ : Shenzhen LCS Compliance Testing Laboratory Ltd. Address .......................................... : 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Testing Location/ Procedure .......... : Full application of Harmonised standards ■ Partial application of Harmonised standards □ Other standard testing method □ Applicant’s Name ......................... : PHILLIPS CONNECT TECHNOLOGIES LLC Address .......................................... : 5231 California Avenue, Suite 110, Irvine, CA 92617 Test Specification Standard ......................................... : FCC CFR 47 PART 15 C(15.247) Test Report Form No.................... : LCSEMC-1.0 TRF Originator ................................ : Shenzhen LCS Compliance Testing Laboratory Ltd. Master TRF ..................................... : Dated 2011-03 Shenzhen LCS Compliance Testing Laboratory Ltd. All rights reserved. This publication may be reproduced in whole or in part for non-commercial purposes as long as the Shenzhen LCS Compliance Testing Laboratory Ltd. is acknowledged as copyright owner and source of the material. Shenzhen LCS Compliance Testing Laboratory Ltd. takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. EUT Description. .......................... : Dagger QG and Dagger QG Slim Trade Mark ..................................... : N/A Test Model ...................................... : 4-8470-10 Ratings ........................................... : Input: DC 12V DC 3.6V by Battery, 5Ah Result ............................................ : Positive Compiled by: Supervised by: Approved by: Jin Wang/ Administrator Cary Luo/ Technique principal Gavin Liang/ Manager Page 3 of 33 FCC ID: 2ASKH-DQG01 Report No.: LCS220309059AEA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity FCC -- TEST REPORT Test Model............................... : 4-8470-10 EUT......................................... : Dagger QG and Dagger QG Slim Applicant............................... : PHILLIPS CONNECT TECHNOLOGIES LLC Address.................................. : 5231 California Avenue, Suite 110, Irvine, CA 92617 Telephone............................... : / Fax.......................................... : / Manufacturer........................ : PHILLIPS CONNECT TECHNOLOGIES LLC Address................................... : 5231 California A…
Text truncated - open the document above for the full version.
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 1.20 mW |

DOOR STATUS INDICATOR
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
CARGOVISION
Equipment Class
DXX - Part 15 Low Power Communication Device TransmitterStealthNet 1928
Equipment Class
PCB - PCS Licensed Transmitter
Smart-7 Pro
Equipment Class
DTS - Digital Transmission System
Battery Operated LTE Celluar GPS Tracker
Equipment Class
PCB - PCS Licensed Transmitter