Instruction Manual ELOshield: driver-assistance system for vehicle safety that automatically helps avoid collisions to reduce risk of vehicle-pedestrian accidents Revision 20 For software version 1.2.0.9 09.03.2020 INSTRUCTION MANUAL Winning solution Instruction manual I ELOshield Rev. 20 09.03.2020 Page 2 of 85 CONTENT 1. IMPORTANT INFORMATION .................................................................................................................. 4 1.1 Risk assessment ............................................................................................................................................ 6 1.2 Electromagnetic wave radiation ................................................................................................................... 7 1.3 Operation of ELOshield ................................................................................................................................. 7 2. MAIN FUNCTIONALITY OF THE MODULES .............................................................................................. 8 2.1 Vehicle/stationary antenna modules (A) ...................................................................................................... 8 2.2 Pedestrian module ....................................................................................................................................... 8 2.3 Vehicle/stationary antenna module (B) ....................................................................................................... 8 2.4 Vehicle module ............................................................................................................................................. 8 3. INTERACTION BETWEEN MODULES ....................................................................................................... 9 4. SCOPE OF DELIVERY ............................................................................................................................. 13 4.1 Vehicle set .................................................................................................................................................. 13 4.2 Stationary set and verification unit. ........................................................................................................... 13 4.3 Pedestrian set ............................................................................................................................................. 14 4.4 Accessories ................................................................................................................................................. 15 5. USE AND OPERATION OF THE PEDESTRIAN MODULE AND CHARGER ................................................... 16 5.1 Operating modes ........................................................................................................................................ 17 5.2 Q button ..................................................................................................................................................... 18 5.3 Warning and informing the operator ......................................................................................................... 18 5.4 Charging the battery ................................................................................................................................... 19 5.4.1 Use the standard charger supplied with the pedestrian module as follows: ............................................. 19 5.5 Correct use of the pedestrian module........................................................................................................ 20 6. USE AND OPERATION OF THE VEHICLE MODULE ................................................................................. 23 6.1 Operating modes ........................................................................................................................................ 23 6.2 Warning and informing the operator ......................................................................................................... 24 6.3 Inputs/outputs ............................................................................................................................................ 25 6.4 Zones .......................................................................................................................................................... 25 6.5 Mechanical installation ............................................................................................................................... 25 6.5.1 Vehicle modules ......................................................................................................................................... 26 6.5.2 Antenna modules (A) .................................................................................................................................. 26 6.5.3 Antenna module (B) ................................................................................................................................... 31 6.5.4 Vehicle module ........................................................................................................................................... 32 6.6 Electrical installation .................................................................................................................................. 32 6.6.1 Assigning connection cables ....................................................................................................................... 33 6.6.2 Example connections in X1 group .............................................................................................................. 35 7. USE AND OPERATION OF THE STATIONARY MODULE .......................................................................... 37 7.1 Warning and informing ............................................................................................................................... 37 7.2 Inputs/outputs ......…
Text truncated - open the document above for the full version.
ELOKON GmbH Gärtnerweg 49 25436 Tornesch / GERMANY T. +49 4122 9570-0 E. [email protected] www.elokon.com Bankverbindung / Banking Account Sparkasse Westholstein BIC NOLADE21WHO IBAN DE60 2225 0020 0000 193003 Amtsgericht / Court of Jurisdiction Elmshorn, HRB Nr. / No. 1534 USt.ID-Nr. / VAT No. DE 175 589 136 Steuer-Nr. / Tax No. 1829409317 Finanzamt / Finance Office Itzehoe Geschäftsführer / Managing Directors Dr. Volker Auerbach Alexander Glasmacher Tornesch, Germany, 2019-17-06 External Photos ELOshield Antenna Module FCC: 2ASP7-ANTM-V01 FRN No: 0028314623 Confirmation of identity Herewith I confirm that antenna A (ELOKON Article EU 100856/US 101062) and antenna B (ELOKON article EU 100867/US101063) are electrically identic, just the firmware is different. The only difference is the label, named A or B. Sincerely, ELOKON GmbH Contact: Dr. Kai Haake Head of Engineering & Product Management T. +49 4122 9570-36 E. [email protected] Seite 2 von 4 ELOKON GmbH Gärtnerweg 49 25436 Tornesch / GERMANY T. +49 4122 9570-0 E. [email protected] www.elokon.com Bankverbindung / Banking Account Sparkasse Westholstein BIC NOLADE21WHO IBAN DE60 2225 0020 0000 193003 Amtsgericht / Court of Jurisdiction Elmshorn, HRB Nr. / No. 1534 USt.ID-Nr. / VAT No. DE 175 589 136 Steuer-Nr. / Tax No. 1829409317 Finanzamt / Finance Office Itzehoe Geschäftsführer / Managing Directors Dr. Volker Auerbach Alexander Glasmacher Seite 3 von 4 ELOKON GmbH Gärtnerweg 49 25436 Tornesch / GERMANY T. +49 4122 9570-0 E. [email protected] www.elokon.com Bankverbindung / Banking Account Sparkasse Westholstein BIC NOLADE21WHO IBAN DE60 2225 0020 0000 193003 Amtsgericht / Court of Jurisdiction Elmshorn, HRB Nr. / No. 1534 USt.ID-Nr. / VAT No. DE 175 589 136 Steuer-Nr. / Tax No. 1829409317 Finanzamt / Finance Office Itzehoe Geschäftsführer / Managing Directors Dr. Volker Auerbach Alexander Glasmacher Seite 4 von 4 ELOKON GmbH Gärtnerweg 49 25436 Tornesch / GERMANY T. +49 4122 9570-0 E. [email protected] www.elokon.com Bankverbindung / Banking Account Sparkasse Westholstein BIC NOLADE21WHO IBAN DE60 2225 0020 0000 193003 Amtsgericht / Court of Jurisdiction Elmshorn, HRB Nr. / No. 1534 USt.ID-Nr. / VAT No. DE 175 589 136 Steuer-Nr. / Tax No. 1829409317 Finanzamt / Finance Office Itzehoe Geschäftsführer / Managing Directors Dr. Volker Auerbach Alexander Glasmacher
ELOKON GmbH Gärtnerweg 49 25436 Tornesch / GERMANY T. +49 4122 9570-0 E. [email protected] www.elokon.com Bankverbindung / Banking Account Sparkasse Westholstein BIC NOLADE21WHO IBAN DE60 2225 0020 0000 193003 Amtsgericht / Court of Jurisdiction Elmshorn, HRB Nr. / No. 1534 USt.ID-Nr. / VAT No. DE 175 589 136 Steuer-Nr. / Tax No. 1829409317 Finanzamt / Finance Office Itzehoe Geschäftsführer / Managing Directors Dr. Volker Auerbach Alexander Glasmacher Tornesch, Germany April, 25th, 2019 External Photos ELOshield Antenna Module FCC: 2ASP7-ANTM-V01 FRN No: 0028314623 Contact: Thomas Linke Produktmanager ELOshield T. +49 4122 9570-35 M [email protected] Seite 2 von 2 ELOKON GmbH Gärtnerweg 49 25436 Tornesch / GERMANY T. +49 4122 9570-0 E. [email protected] www.elokon.com Bankverbindung / Banking Account Sparkasse Westholstein BIC NOLADE21WHO IBAN DE60 2225 0020 0000 193003 Amtsgericht / Court of Jurisdiction Elmshorn, HRB Nr. / No. 1534 USt.ID-Nr. / VAT No. DE 175 589 136 Steuer-Nr. / Tax No. 1829409317 Finanzamt / Finance Office Itzehoe Geschäftsführer / Managing Directors Dr. Volker Auerbach Alexander Glasmacher
ELOKON GmbH Gärtnerweg 49 25436 Tornesch / GERMANY T. +49 4122 9570-0 E. [email protected] www.elokon.com Bankverbindung / Banking Account Sparkasse Westholstein BIC NOLADE21WHO IBAN DE60 2225 0020 0000 193003 Amtsgericht / Court of Jurisdiction Elmshorn, HRB Nr. / No. 1534 USt.ID-Nr. / VAT No. DE 175 589 136 Steuer-Nr. / Tax No. 1829409317 Finanzamt / Finance Office Itzehoe Geschäftsführer / Managing Directors Dr. Volker Auerbach Alexander Glasmacher Tornesch, Germany April, 25th, 2019 Internal Photos ELOshield Antenna Module FCC: 2ASP7-ANTM_V01 FRN No: 0028314623 Seite 2 von 2 ELOKON GmbH Gärtnerweg 49 25436 Tornesch / GERMANY T. +49 4122 9570-0 E. [email protected] www.elokon.com Bankverbindung / Banking Account Sparkasse Westholstein BIC NOLADE21WHO IBAN DE60 2225 0020 0000 193003 Amtsgericht / Court of Jurisdiction Elmshorn, HRB Nr. / No. 1534 USt.ID-Nr. / VAT No. DE 175 589 136 Steuer-Nr. / Tax No. 1829409317 Finanzamt / Finance Office Itzehoe Geschäftsführer / Managing Directors Dr. Volker Auerbach Alexander Glasmacher Antenna PCB Contact: Thomas Linke Produktmanager ELOshield T. +49 4122 9570-35 M [email protected]
Annex 3 to Test Report 18-1-0029001T04a, Page 1 of 4 CETECOM_TR18_1_0029001T04a-A3 Annex 3: Internal photographs of EUT to T E S T R E P O R T No.: 18-1-0039001T04a ELOshield antenna module FCC ID: 2ASP7-ANTM-V01 According to: 47 CFR Part 15.519 ELOKON GmbH for Laboratory Accreditation accredited according to DIN EN ISO/IEC 17025 CETECOM GmbH Laboratory Radio Communications & Electromagnetic Compatibility Im Teelbruch 116 • 45219 Essen • Germany Registered in Essen, Germany, Reg. No.: HRB Essen 8984 Tel.: + 49 (0) 20 54 / 95 19-954 • Fax: + 49 (0) 20 54 / 95 19-964 E-mail: [email protected] • Internet: www.cetecom.com Annex 3 to Test Report 18-1-0029001T04a, Page 2 of 4 CETECOM_TR18_1_0029001T04a-A3 TABLE OF CONTENTS: 1. INTERNAL PHOTOGRAPHS ........................................................................................................................ 3 Annex 3 to Test Report 18-1-0029001T04a, Page 3 of 4 CETECOM_TR18_1_0029001T04a-A3 1. Internal photographs Photograph 1: top and bottom part, overall view 1 Photograph 2: top and bottom part, overall view 2 Annex 3 to Test Report 18-1-0029001T04a, Page 4 of 4 CETECOM_TR18_1_0029001T04a-A3 Photograph 3: top part, close view 1 Photograph 4: top part, close view 2
Page 1 of 27 The test results relate only to the individual items that have been tested. This report shall not be reproduced in parts without the written approval of the testing laboratory © Copyright: All rights reserved by CETECOM Annex 1: Measurement diagrams to T E S T R E P O R T No.: 18-1-0029001T04a ELOshield antenna module FCC ID: 2ASP7-ANTM-V01 According to: 47 CFR Part 15.519 ELOKON GmbH Laboratory Accreditation accredited according to DIN EN ISO/IEC 17025 CETECOM GmbH Laboratory Radio Communications & Electromagnetic Compatibility Im Teelbruch 116 • 45219 Essen • Germany Registered in Essen, Germany, Reg. No.: HRB Essen 8984 Tel.: + 49 (0) 20 54 / 95 19-954 • Fax: + 49 (0) 20 54 / 95 19-964 E-mail: [email protected] • Internet: www.cetecom.com for Annex 1 to Test Report 18-1-0029001T04a, Page 2 of 27 CETECOM_TR18_1_0029001T04a-A1 TABLE OF CONTENTS: 1. TRANSMISSION TIME MEASUREMENT ................................................................................................. 4 1.1. EUT A and AE 4 are ON. ............................................................................................................................. 4 1.2. 1.2. EUT A is ON, AE 4 is deactivated app. at time M1 .............................................................................. 4 2. 10 DB BANDWIDTH MEASUREMENT ....................................................................................................... 5 2.1. Op. Mode 1 ................................................................................................................................................... 5 2.2. Op. Mode 2 ................................................................................................................................................... 5 2.3. Op. mode 3 ................................................................................................................................................... 6 2.4. Op. Mode 4 ................................................................................................................................................... 6 2.5. Op. Mode 5 ................................................................................................................................................... 7 2.6. Op. Mode 6 ................................................................................................................................................... 7 2.7. Op. Mode 7 ................................................................................................................................................... 8 3. GENERAL LIMIT - RADIATED FIELD STRENGTH EMISSIONS BELOW 30 MHZ ......................... 9 3.1. Op. Mode 1 and 7, laying ............................................................................................................................. 9 3.2. Op. Mode 1 and 7, standing .......................................................................................................................... 9 4. GENERAL LIMIT - RADIATED FIELD STRENGTH EMISSIONS, 30 MHZ - 1 GHZ ...................... 10 4.1. Op. Mode 1 and 7, laying ........................................................................................................................... 10 4.2. Op. Mode 1 and 7, standing ........................................................................................................................ 10 5. GENERAL LIMIT – RADIATED FIELD STRENGTH EMISSIONS, ABOVE 960 MHZ .................... 11 5.1. Frequency range 960 MHz – 1610 MHz, op. mode 1 and 7, ANT HOR ................................................... 11 5.2. Frequency range 960 MHz – 1610 MHz, op. mode 1 and 7, ANT VER .................................................... 11 5.3. Frequency range 1610 MHz – 4193 MHz, op. mode 1 and 7, ANT HOR ................................................. 12 5.4. Frequency range 1610 MHz – 4193 MHz, op. mode 1 and 7, ANT VER .................................................. 12 5.5. UWB cen. frequency with span 600 MHz, 600 pts, SWT 600ms, op. mode 1 and 7, 4192.8 MHz – 4792.8 MHz, ANT HOR ............................................................................................................................................... 13 5.6. UWB cen. frequency with span 600 MHz, 600 pts, SWT 600ms, op. mode 1 and 7, 4192.8 MHz – 4792.8 MHz, ANT VER ................................................................................................................................................ 13 5.7. UWB cen. frequency with span 600 MHz, 600 pts, SWT 600ms, op. mode 2 + 7 ..................................... 14 5.8. UWB cen. frequency with span 600 MHz, 600 pts, SWT 600ms, op. mode 3 + 7 ..................................... 14 5.9. UWB cen. frequency with span 600 MHz, 600 pts, SWT 600ms, op. mode 4 + 7 ..................................... 15 5.10. UWB cen. frequency with span 600 MHz, 600 pts, SWT 600ms, op. mode 5 + 7 ................................... 15 5.11. UWB cen. frequency with span 600 MHz, 600 pts, SWT 600ms, op. mode 6 + 7 ................................... 16 5.12. Frequency range 4792 MHz – 5940 MHz, op. mode 1 and 7, ANT HOR ............................................... 16 5.13. Frequency range 4792 MHz – 5940 MHz, op. mode 1 and 7, ANT VER ................................................ 17 5.14. Frequency range 5940 MHz – 8000 MHz, op. mode 1, ANT HOR ......................................................... 17 5.15. Frequency range 5940 MHz – 8000 MHz, op. mode 1, ANT VER .......................................................... 18 5.16. UWB cen. frequency with span 1100 MHz, 1100 pts, SWT 1s, op. mode 1 and 7 .................................. 18 5.17. Frequency range 7039 MHz – 8000 MHz, op. mode 1 + 7, ANT HOR ................................................... 19 5.18. Frequency range 7039 MHz – 8000 MHz, op. mode 1 + 7, ANT VER ................................................... 19 5.19. Frequency range 8000 MHz – 106…
Text truncated - open the document above for the full version.
Page 1 of 26 The test results relate only to the individual items which have been tested. This report shall not be reproduced in parts without the written approval of the testing laboratory © Copyright: All rights reserved by CETECOM T E S T R E P O R T No.: 18-1-0029001T04a ELOshield antenna module FCC ID: 2ASP7-ANTM-V01 According to: 47 CFR Part 15.519 ELOKON GmbH for Laboratory Accreditation accredited according to DIN EN ISO/IEC 17025 CETECOM GmbH Laboratory Radio Communications & Electromagnetic Compatibility Im Teelbruch 116 • 45219 Essen • Germany Registered in Essen, Germany, Reg. No.: HRB Essen 8984 Tel.: + 49 (0) 20 54 / 95 19-954 • Fax: + 49 (0) 20 54 / 95 19-964 E-mail: [email protected] • Internet: www.cetecom.com Test Report 18-1-0029001T04a, Page 2 of 26 CETECOM_TR18_1_0029001T04a Table of contents 1. SUMMARY OF TEST RESULTS................................................................................................................... 3 1.1. Tests measurement overview according of US CFR Title 47, Subpart 15F: ................................................ 3 1.2. Attestation:.................................................................................................................................................... 4 2. ADMINISTRATIVE DATA ............................................................................................................................ 5 2.1. Identification of the testing laboratory .......................................................................................................... 5 2.2. Test location ................................................................................................................................................. 5 2.3. Organizational items ..................................................................................................................................... 5 2.4. Applicant’s details ........................................................................................................................................ 5 2.5. Manufacturer’s details .................................................................................................................................. 5 3. EQUIPMENT UNDER TEST (EUT) .............................................................................................................. 6 3.1. TECHNICAL DATA OF MAIN EUT DECLARED BY APPLICANT ...................................................... 6 3.2. EUT: Type, S/N etc. and short descriptions used in this test report ............................................................. 6 3.3. Auxiliary Equipment (AE): Type, S/N etc. and short descriptions ............................................................... 6 3.4. EUT set-ups .................................................................................................................................................. 7 3.5. EUT operating modes ................................................................................................................................... 7 4. DESCRIPTION OF TEST SYSTEM SET-UP’S ........................................................................................... 8 4.1. Test system set-up for radiated magnetic field measurements below 30 MHz ............................................. 8 4.2. Test system set-up for radiated electric field measurement 30 MHz to 960MHz ......................................... 9 4.3. Test system set-up for radiated electric field measurement above 960MHz .............................................. 10 5. MEASUREMENTS ........................................................................................................................................ 11 5.1. Transmission time measurement ................................................................................................................ 11 5.2. 10 dB bandwidth measurement ................................................................................................................... 12 5.3. General Limit - Radiated field strength emissions below 30 MHz ............................................................. 13 5.4. General Limit - Radiated field strength emissions, 30 MHz – 960 MHz ................................................... 15 5.5. General Limit – Radiated field strength emissions, above 960 MHz ......................................................... 17 5.6. Radiated emissions in the GPS bands ......................................................................................................... 19 5.7. Fundamental emission peak power ............................................................................................................. 20 5.8. Antenna requirement according to FCC 15.203 ......................................................................................... 20 5.9. Measurement uncertainties ...................................................................................................................... 21 6. ABBREVIATIONS USED IN THIS REPORT ............................................................................................ 22 7. ACCREDITATION DETAILS OF CETECOM’S LABORATORIES AND TEST SITES .................... 22 8. INSTRUMENTS AND ANCILLARY ........................................................................................................... 23 8.1. Used equiment “CTC” ............................................................................................................................. 23 9. VERSIONS OF TEST REPORTS (CHANGE HISTORY) ........................................................................ 26 Table of annex Separate document annex 1: Measurement diagrams Separate document annex 2: External photographs of EUT Separate document annex 3: Internal photographs of EUT Separate document annex 4: Test set-up photographs The listed attachments are an integral part of this report. Test Report 18-1-0029001T04a, Page 3 of 26 CETECO…
Text truncated - open the document above for the full version.
Annex 4 to Test Report 18_1_0029001T04a, Page 1 of 9 CETECOM_TR18_1_0029001T04a-A4 Annex 4: Set-up photographs to to T E S T R E P O R T No.: 18-1-0039001T04a ELOshield antenna module FCC ID: 2ASP7-ANTM-V01 According to: 47 CFR Part 15.519 ELOKON GmbH Laboratory Accreditation accredited according to DIN EN ISO/IEC 17025 CETECOM GmbH Laboratory Radio Communications & Electromagnetic Compatibility Im Teelbruch 116 • 45219 Essen • Germany Registered in Essen, Germany, Reg. No.: HRB Essen 8984 Tel.: + 49 (0) 20 54 / 95 19-954 • Fax: + 49 (0) 20 54 / 95 19-964 E-mail: [email protected] • Internet: www.cetecom.com for Annex 4 to Test Report 18_1_0029001T04a, Page 2 of 9 CETECOM_TR18_1_0029001T04a-A4 TABLE OF CONTENTS: 1. TRANSMISSION TIME MEASUREMENT ................................................................................................. 3 2. 10 DB BANDWIDTH MEASUREMENT ....................................................................................................... 3 3. RADIATED RF-MEASUREMENTS SET-UP ............................................................................................... 4 3.1. Radiated Field Strength Emissions – 9 kHz to 30 MHz ............................................................................... 4 3.2. Radiated Field Strength Emissions - 30 MHz to 960 MHz .......................................................................... 5 3.3. Radiated Field Strength Emissions – 960 MHz – 4193 MHz ....................................................................... 6 3.4. Radiated Field Strength Emissions – 4193 MHz – 15000 MHz ................................................................... 7 3.5. Radiated Field Strength Emissions –15000 MHz – 40000 MHz .................................................................. 8 4. RADIATED EMISSIONS IN THE GPS BANDS .......................................................................................... 9 4.1. Frequency range 1164 MHz – 1240 MHz .................................................................................................... 9 4.2. Frequency range 1559 MHz – 1610 MHz .................................................................................................... 9 5. FUNDAMENTAL EMISSION PEAK POWER ............................................................................................ 9 Annex 4 to Test Report 18_1_0029001T04a, Page 3 of 9 CETECOM_TR18_1_0029001T04a-A4 1. Transmission time measurement See chapter 3.4 2. 10 dB bandwidth measurement See chapter 3.4 Annex 4 to Test Report 18_1_0029001T04a, Page 4 of 9 CETECOM_TR18_1_0029001T04a-A4 3. Radiated RF-Measurements Set-up 3.1. Radiated Field Strength Emissions – 9 kHz to 30 MHz Photograph 1: Overall View Photograph 2: Close View Annex 4 to Test Report 18_1_0029001T04a, Page 5 of 9 CETECOM_TR18_1_0029001T04a-A4 3.2. Radiated Field Strength Emissions - 30 MHz to 960 MHz Photograph 3: Overall View For close view see photograph 2. Annex 4 to Test Report 18_1_0029001T04a, Page 6 of 9 CETECOM_TR18_1_0029001T04a-A4 3.3. Radiated Field Strength Emissions – 960 MHz – 4193 MHz Photograph 4: Overall View Photograph 5: Close View Annex 4 to Test Report 18_1_0029001T04a, Page 7 of 9 CETECOM_TR18_1_0029001T04a-A4 3.4. Radiated Field Strength Emissions – 4193 MHz – 15000 MHz Photograph 6: Overall View For close view see photograph 5. Annex 4 to Test Report 18_1_0029001T04a, Page 8 of 9 CETECOM_TR18_1_0029001T04a-A4 3.5. Radiated Field Strength Emissions –15000 MHz – 40000 MHz Please see photograph 5. Annex 4 to Test Report 18_1_0029001T04a, Page 9 of 9 CETECOM_TR18_1_0029001T04a-A4 4. Radiated emissions in the GPS bands 4.1. Frequency range 1164 MHz – 1240 MHz See chapter 3.4 4.2. Frequency range 1559 MHz – 1610 MHz See chapter 3.4 5. Fundamental emission peak power See chapter 3.4
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15F | 3.10 GHz - 7.00 GHz | - |

ELOshield Verification Module
Equipment Class
JAB - Part 15 Class B Digital Device
ELOshield Pedestrian Module
Equipment Class
UWB - Ultra Wideband Transmitter
ELOshield Stationary Module
Equipment Class
JAB - Part 15 Class B Digital Device