FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. ELOKON GmbH/
  3. 2ASP7-STATM-V01

2ASP7-STATM-V01ELOshield Stationary Module

ELOKON GmbH
ELOshield Stationary Module - FCC ID 2ASP7-STATM-V01 - ELOKON GmbH
Click to zoom

Application Details

Equipment Class
JAB - Part 15 Class B Digital Device
Date of Grant
Mar 19, 2020
Application Purpose
Original Equipment
Date of Application
Mar 19, 2020
Equipment Note
ELOshield Stationary Module
Company
ELOKON GmbH
Country
Germany

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗

External Photos

↗
↗

ID Label/Location Info

↗

Internal Photos

↗
↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Instruction Manual ELOshield: driver-assistance system for vehicle safety that automatically helps avoid collisions to reduce risk of vehicle-pedestrian accidents Revision 20 For software version 1.2.0.9 09.03.2020 INSTRUCTION MANUAL Winning solution Instruction manual I ELOshield Rev. 20 09.03.2020 Page 2 of 85 CONTENT 1. IMPORTANT INFORMATION .................................................................................................................. 4 1.1 Risk assessment ............................................................................................................................................ 6 1.2 Electromagnetic wave radiation ................................................................................................................... 7 1.3 Operation of ELOshield ................................................................................................................................. 7 2. MAIN FUNCTIONALITY OF THE MODULES .............................................................................................. 8 2.1 Vehicle/stationary antenna modules (A) ...................................................................................................... 8 2.2 Pedestrian module ....................................................................................................................................... 8 2.3 Vehicle/stationary antenna module (B) ....................................................................................................... 8 2.4 Vehicle module ............................................................................................................................................. 8 3. INTERACTION BETWEEN MODULES ....................................................................................................... 9 4. SCOPE OF DELIVERY ............................................................................................................................. 13 4.1 Vehicle set .................................................................................................................................................. 13 4.2 Stationary set and verification unit. ........................................................................................................... 13 4.3 Pedestrian set ............................................................................................................................................. 14 4.4 Accessories ................................................................................................................................................. 15 5. USE AND OPERATION OF THE PEDESTRIAN MODULE AND CHARGER ................................................... 16 5.1 Operating modes ........................................................................................................................................ 17 5.2 Q button ..................................................................................................................................................... 18 5.3 Warning and informing the operator ......................................................................................................... 18 5.4 Charging the battery ................................................................................................................................... 19 5.4.1 Use the standard charger supplied with the pedestrian module as follows: ............................................. 19 5.5 Correct use of the pedestrian module........................................................................................................ 20 6. USE AND OPERATION OF THE VEHICLE MODULE ................................................................................. 23 6.1 Operating modes ........................................................................................................................................ 23 6.2 Warning and informing the operator ......................................................................................................... 24 6.3 Inputs/outputs ............................................................................................................................................ 25 6.4 Zones .......................................................................................................................................................... 25 6.5 Mechanical installation ............................................................................................................................... 25 6.5.1 Vehicle modules ......................................................................................................................................... 26 6.5.2 Antenna modules (A) .................................................................................................................................. 26 6.5.3 Antenna module (B) ................................................................................................................................... 31 6.5.4 Vehicle module ........................................................................................................................................... 32 6.6 Electrical installation .................................................................................................................................. 32 6.6.1 Assigning connection cables ....................................................................................................................... 33 6.6.2 Example connections in X1 group .............................................................................................................. 35 7. USE AND OPERATION OF THE STATIONARY MODULE .......................................................................... 37 7.1 Warning and informing ............................................................................................................................... 37 7.2 Inputs/outputs ......…

Text truncated - open the document above for the full version.

External Photos

ELOKON GmbH Gärtnerweg 49 25436 Tornesch / GERMANY T. +49 4122 9570-0 E. [email protected] www.elokon.com Bankverbindung / Banking Account Sparkasse Westholstein BIC NOLADE21WHO IBAN DE60 2225 0020 0000 193003 Amtsgericht / Court of Jurisdiction Elmshorn, HRB Nr. / No. 1534 USt.ID-Nr. / VAT No. DE 175 589 136 Steuer-Nr. / Tax No. 1829409317 Finanzamt / Finance Office Itzehoe Geschäftsführer / Managing Directors Dr. Volker Auerbach Alexander Glasmacher Tornesch, Germany April, 25th, 2019 External Photos ELOshield Stationary Module FCC: 2ASP7-STATM-V01 FRN No: 0028314623 Contact: Thomas Linke Produktmanager ELOshield T. +49 4122 9570-35 M [email protected] Seite 2 von 2 ELOKON GmbH Gärtnerweg 49 25436 Tornesch / GERMANY T. +49 4122 9570-0 E. [email protected] www.elokon.com Bankverbindung / Banking Account Sparkasse Westholstein BIC NOLADE21WHO IBAN DE60 2225 0020 0000 193003 Amtsgericht / Court of Jurisdiction Elmshorn, HRB Nr. / No. 1534 USt.ID-Nr. / VAT No. DE 175 589 136 Steuer-Nr. / Tax No. 1829409317 Finanzamt / Finance Office Itzehoe Geschäftsführer / Managing Directors Dr. Volker Auerbach Alexander Glasmacher

External Photos

Page 1 of 7 The test results relate only to the individual items which have been tested. This report shall not be reproduced in parts without the written approval of the testing laboratory © Copyright: All rights reserved by CETECOM Annex 3: External photographs to T E S T R E P O R T No.: 18-1-0029001T01a Stationary Module ELOShield Warning System 100868 FCC-ID: 2ASP7-STATM-V01 Laboratory Accreditation accredited according to DIN EN ISO/IEC 17025 CETECOM GmbH Laboratory Radio Communications & Electromagnetic Compatibility Im Teelbruch 116 • 45219 Essen • Germany Registered in Essen, Germany, Reg. No.: HRB Essen 8984 Tel.: + 49 (0) 20 54 / 95 19-954 • Fax: + 49 (0) 20 54 / 95 19-964 E-mail: [email protected] • Internet: www.cetecom.com According to: Title 47 - FCC Regulations Part 15, Subpart B §5.107, §15.109 ELOKON GmbH for Annex 3 to Test Report 18-1-0029001T01a, Page 2 of 7 CETECOM_TR18_1_0029001T01a_A3.docx Table of contents 1. EXTERNAL PHOTOGRAPHS.......................................................................................................................... 3 1.1. EUTs ................................................................................................................................................................ 3 1.2. Auxiliary equipment ........................................................................................................................................ 6 Annex 3 to Test Report 18-1-0029001T01a, Page 3 of 7 CETECOM_TR18_1_0029001T01a_A3.docx 1. External photographs 1.1. EUTs Figure 1: EUT top side view Figure 2: EUT side view Annex 3 to Test Report 18-1-0029001T01a, Page 4 of 7 CETECOM_TR18_1_0029001T01a_A3.docx Figure 3: EUT bottom side view Figure 4: EUT side view Annex 3 to Test Report 18-1-0029001T01a, Page 5 of 7 CETECOM_TR18_1_0029001T01a_A3.docx Figure 5: Cetecom marking Figure 6: ELOKON marking Annex 3 to Test Report 18-1-0029001T01a, Page 6 of 7 CETECOM_TR18_1_0029001T01a_A3.docx 1.2. Auxiliary equipment Figure 7: USB cable Figure 8: USB stick Annex 3 to Test Report 18-1-0029001T01a, Page 7 of 7 CETECOM_TR18_1_0029001T01a_A3.docx Figure 9: Can Bus cable

ID Label/Location Info

ELOKON GmbH Gärtnerweg 49 25436 Tornesch / GERMANY T. +49 4122 9570-0 E. [email protected] www.elokon.com Bankverbindung / Banking Account Sparkasse Westholstein BIC NOLADE21WHO IBAN DE60 2225 0020 0000 193003 Amtsgericht / Court of Jurisdiction Elmshorn, HRB Nr. / No. 1534 USt.ID-Nr. / VAT No. DE 175 589 136 Steuer-Nr. / Tax No. 1829409317 Finanzamt / Finance Office Itzehoe Geschäftsführer / Managing Directors Dr. Volker Auerbach Alexander Glasmacher Tornesch, Germany April, 25th, 2019 Label location info ELOshield Stationary Module FCC ID: 2ASP7-STATM-V01 FRN No: 0028314623 Front side Right side Contact: Thomas Linke Produktmanager ELOshield T. +49 4122 9570-35 M [email protected] Seite 2 von 2 ELOKON GmbH Gärtnerweg 49 25436 Tornesch / GERMANY T. +49 4122 9570-0 E. [email protected] www.elokon.com Bankverbindung / Banking Account Sparkasse Westholstein BIC NOLADE21WHO IBAN DE60 2225 0020 0000 193003 Amtsgericht / Court of Jurisdiction Elmshorn, HRB Nr. / No. 1534 USt.ID-Nr. / VAT No. DE 175 589 136 Steuer-Nr. / Tax No. 1829409317 Finanzamt / Finance Office Itzehoe Geschäftsführer / Managing Directors Dr. Volker Auerbach Alexander Glasmacher Label detailed

Internal Photos

ELOKON GmbH Gärtnerweg 49 25436 Tornesch / GERMANY T. +49 4122 9570-0 E. [email protected] www.elokon.com Bankverbindung / Banking Account Sparkasse Westholstein BIC NOLADE21WHO IBAN DE60 2225 0020 0000 193003 Amtsgericht / Court of Jurisdiction Elmshorn, HRB Nr. / No. 1534 USt.ID-Nr. / VAT No. DE 175 589 136 Steuer-Nr. / Tax No. 1829409317 Finanzamt / Finance Office Itzehoe Geschäftsführer / Managing Directors Dr. Volker Auerbach Alexander Glasmacher Tornesch, Germany, April, 25th, 2019 Internal Photos ELOshield Stationary Module FCC: 2ASP7-STATM-V01 FRN No: 0028314623 Contact: Thomas Linke Produktmanager ELOshield T. +49 4122 9570-35 M [email protected]

Internal Photos

Page 1 of 3 The test results relate only to the individual items which have been tested. This report shall not be reproduced in parts without the written approval of the testing laboratory © Copyright: All rights reserved by CETECOM Annex 2: Internal photographs to T E S T R E P O R T No.: 18-1-0029001T01a Stationary Module ELOshield Warning System 100868 FCC-ID: 2ASP7-STATM-V01 According to: Title 47 - FCC Regulations Part 15, Subpart B §5.107, §15.109 ELOKON GmbH Laboratory Accreditation accredited according to DIN EN ISO/IEC 17025 CETECOM GmbH Laboratory Radio Communications & Electromagnetic Compatibility Im Teelbruch 116 • 45219 Essen • Germany Registered in Essen, Germany, Reg. No.: HRB Essen 8984 Tel.: + 49 (0) 20 54 / 95 19-954 • Fax: + 49 (0) 20 54 / 95 19-964 E-mail: [email protected] • Internet: www.cetecom.com for Annex 2 to Test Report 18-1-0029001T01a, Page 2 of 3 CETECOM_TR_18_1_0029001T01a_A2 Table of contents 1. INTERNAL PHOTOGRAPHS ........................................................................................................................... 3 Annex 2 to Test Report 18-1-0029001T01a, Page 3 of 3 CETECOM_TR_18_1_0029001T01a_A2 1. Internal photographs Figure 2: EUT inside view Figure 3: EUT inside view

Test Report

Page 1 of 5 The test results relate only to the individual items which have been tested. This report shall not be reproduced in parts without the written approval of the testing laboratory © Copyright: All rights reserved by CETECOM Annex 1: Measurement diagrams to T E S T R E P O R T No.: 18-1-0029001T01a for Stationary Module ELOShield Warning System 100868 FCC-ID: 2ASP7-STATM-V01 According to: Title 47 - FCC Regulations Part 15, Subpart B §5.107, §15.109 ELOKON GmbH Laboratory Accreditation accredited according to DIN EN ISO/IEC 17025 CETECOM GmbH Laboratory Radio Communications & Electromagnetic Compatibility Im Teelbruch 116 • 45219 Essen • Germany Registered in Essen, Germany, Reg. No.: HRB Essen 8984 Tel.: + 49 (0) 20 54 / 95 19-954 • Fax: + 49 (0) 20 54 / 95 19-964 E-mail: [email protected] • Internet: www.cetecom.com Annex 1 to Test Report 18-1-0029001T01a, Page 2 of 5 CETECOM_TR18_1_0029001T01a_A1.docx Table of contents 1. MEASUREMENT DIAGRAMS 3 1.1. Conducted emissions on AC Power lines 3 1.2. Radiated emissions in the frequency range 30 to 1000MHz 4 1.3. Radiated emissions in the frequency range above 1000MHz 5 Annex 1 to Test Report 18-1-0029001T01a, Page 3 of 5 CETECOM_TR18_1_0029001T01a_A1.docx 1. Measurement diagrams 1.1. Conducted emissions on AC Power lines 1.01 Common Information Test Description: Conducted Voltage Measurement Class B Test Site & Location: Conducted Emission, CETECOM GmbH Essen Test Software: R&S EMC32 v9.15 Test Specification: §15.107 Operating Mode: Stationery Panel – Relay On/Off – UWB Off Measured on line: 120V AC N/L1 Diagram details: Shows the peak values as a sum of measured ports in maxhold mode Environmental Conditions: Humidity: 45% rH; Temperature: 20° C Operator: JVo EUT Information Manufacturer: ELOKON GmbH Model: Stationery Panel Type: Indoor Warning System EUT: 100868 HW version: 1.1 SW version: 1.1.0.4 Config: Elo Shield Manager 1.1.9.8 Serial number: 18070046 Connected Interfaces: CAN Bus, 120V AC, USB Cable, 2 x Ant Cable Power Supply: 120 V AC Comments: Relay On/Off, UWB Off Frequency (MHz) QuasiPeak (dBμV) CAverage (dBμV) Limit (dBμV) Margin (dB) Bandwidth (kHz) Corr. (dB) 0.200781 37.02 --- 63.58 26.56 9.000 0.1 0.200781 --- 25.86 53.58 27.72 9.000 0.1 0.669531 26.11 --- 56.00 29.89 9.000 0.2 0.669531 --- 24.16 46.00 21.84 9.000 0.2 9.411719 --- 25.85 50.00 24.15 9.000 0.4 9.411719 31.63 --- 60.00 28.37 9.000 0.4 Level in dBμV Annex 1 to Test Report 18-1-0029001T01a, Page 4 of 5 CETECOM_TR18_1_0029001T01a_A1.docx 1.2. Radiated emissions in the frequency range 30 to 1000 MHz 3.01 Common Information Test description: Electric Field Strength Measurement Test site and distance: Ref.-Nr. 441 Semi Anechoic Room (SAR) with 3 m measurement distance Version of Testsoftware: EMC32 V9.25.0 Technical Data: please see page 2 for detailed data of measurement setup Test specification.: §15.109 Class B Operator: HEl Operating conditions: Stationery Panel – Relay On/off- UWB Off Power during tests: 120 V Environmental Conditions: Humidity: 48% rH; Temperature: 20° C Comment 1: -- EUT Information Manufacturer: ELOKON GmbH Model: Stationery Panel Type: Indoor Warning System EUT: 100868 HW version: 1.1 SW version: 1.1.0.4 Config: Elo Shield Manager 1.1.9.8 Serial number: 18070046 Connected Interfaces: CAN Bus, 120V AC, USB Cable, 2 x Ant B Power Supply: 120 V AC Comments: Relay On/off- UWB Off Frequency (MHz) QuasiPeak (dBμV/m) Limit (dBμV/m) Margin (dB) Bandwidth (kHz) Corr. (dB) 42.670000 18.55 40.00 21.45 120.000 16.0 64.200000 22.64 40.00 17.36 120.000 7.5 75.270000 20.52 40.00 19.48 120.000 6.7 87.850000 21.44 40.00 18.56 120.000 8.1 88.760000 24.35 43.50 19.15 120.000 8.1 94.030000 21.05 43.50 22.45 120.000 8.3 111.400000 27.68 43.50 15.82 120.000 8.2 117.710000 27.18 43.50 16.32 120.000 7.9 156.290000 21.83 43.50 21.67 120.000 9.0 171.540000 18.46 43.50 25.04 120.000 10.3 171.980000 17.74 43.50 25.76 120.000 10.3 197.740000 23.42 43.50 20.08 120.000 11.4 208.860000 24.41 43.50 19.09 120.000 11.6 Level in dBμV/m Annex 1 to Test Report 18-1-0029001T01a, Page 5 of 5 CETECOM_TR18_1_0029001T01a_A1.docx 1.3. Radiated emissions in the frequency range above 1000MHz 4.01 Common Information Test Description: Radiated Filed Strength Emission Test Site Location: CETECOM GmbH Essen Test Site: Fully Anechoic Room (FAR) Test Standard: FCC Part 15.109, class B Operating Mode: Relay On/Off, no TX Equipment Class: Class B Environmental Conditions: Humidity: 40% rH; Temperature: 19.7° C Operator: JVo EUT Information Manufacturer: ELOKON GmbH Model: Stationery Panel Type: Indoor Warning System EUT: 100868 HW version: 1.1 SW version: 1.1.0.4 Config: Elo Shield Manager 1.1.9.8 Serial number: 18070046 Connected Interfaces: CAN Bus, 120V AC, USB Cable, 2 x Ant B Power Supply: 120V AC Comments: Relay On/off- UWB Off Frequency (MHz) Limit (dBμV/m) Margin (dB) Bandwidth (kHz) Pol Corr. (dB) 2960.020000 74.00 36.02 1000.000 H -1.3 3173.100000 74.00 34.17 1000.000 V -0.2 3629.460000 74.00 33.85 1000.000 H 0.5 8329.940000 74.00 23.13 1000.000 V 13.6 14826.820000 74.00 14.83 1000.000 H 22.8 Level in dBμV/m

Test Report

Page 1 of 19 The test results relate only to the individual items which have been tested. This report shall not be reproduced in parts without the written approval of the testing laboratory © Copyright: All rights reserved by CETECOM T E S T R E P O R T No.: 18-1-0029001T01a for Stationary Module ELOshield Warning System 100868 FCC-ID: 2ASP7-STATM-V01 According to: Title 47 - FCC Regulations Part 15, Subpart B §5.107, §15.109 ELOKON GmbH Laboratory Accreditation accredited according to DIN EN ISO/IEC 17025 CETECOM GmbH Laboratory Radio Communications & Electromagnetic Compatibility Im Teelbruch 116 • 45219 Essen • Germany Registered in Essen, Germany, Reg. No.: HRB Essen 8984 Tel.: + 49 (0) 20 54 / 95 19-954 • Fax: + 49 (0) 20 54 / 95 19-964 E-mail: [email protected] • Internet: www.cetecom.com Test Report 18-1-0029001T01a, Page 2 of 19 CETECOM_TR18_1_0029001T01a.docx Table of contents 1. SUMMARY OF TEST RESULTS 3 1.1. RX mode, tests overview according FCC Part 15B 3 2. ADMINISTRATIVE DATA 4 2.1. Identification of the testing laboratory 4 2.2. Test location 4 2.3. Organizational items 4 2.4. Applicant’s details 4 2.5. Manufacturer’s details 4 3. EQUIPMENT UNDER TEST (EUT) 5 3.1. TECHNICAL DATA OF MAIN EUT DECLARED BY APPLICANT 5 3.2. EUT: Type, S/N etc. and short descriptions used in this test report 5 3.3. Auxiliary Equipment (AE): Type, S/N etc. and short descriptions 5 3.4. EUT set-ups 5 3.5. EUT operating modes 6 4. DESCRIPTION OF TEST SYSTEM SET-UP’S 7 4.1. Test system set-up for AC power-line conducted emission measurements 7 4.2. Test system set-up for radiated electric field measurement 30 MHz to 1 GHz 8 4.3. Test system set-up for radiated electric field measurement above 1 GHz 9 5. MEASUREMENTS 10 5.1. General Limit - Conducted emissions on AC-Power lines 10 5.2. General Limit - Radiated field strength emissions, 30 MHz - 1 GHz 11 5.3. General Limit - Radiated emissions, above 1 GHz 12 5.4. Measurement uncertainties 13 6. ABBREVIATIONS USED IN THIS REPORT 14 7. ACCREDITATION DETAILS OF CETECOM’S LABORATORIES AND TEST SITES 14 8. INSTRUMENTS AND ANCILLARY 15 8.1. Used equiment “CTC” 15 9. VERSIONS OF TEST REPORTS (CHANGE HISTORY) 19 Table of annex Total pages SEPARATE ANNEX 1: DIAGRAM OF TESTING “CETECOM_TR18_1_0029001T01a_A1” 5 SEPARATE ANNEX 2: INTERNAL PHOTOGRAPHS OF EUT “CETECOM_TR18_1_0029001T01a_A2” 3 SEPARATE ANNEX 3: EXTERNAL PHOTOGRAPHS OF EUT “CETECOM_TR18_1_0029001T01a_A3” 7 SEPARATE ANNEX 4: TEST SETUP PHOTOGRAPHS “CETECOM_TR18_1_0029001T01a_A4” 5 The listed attachments are an integral part of this report. Test Report 18-1-0029001T01a, Page 3 of 19 CETECOM_TR18_1_0029001T01a.docx 1. Summary of test results The test results apply exclusively to the test samples as presented in this Report. The CETECOM GmbH does not assume responsibility for any conclusions and generalizations taken in conjunction with other specimens or samples of the type of the item presented to tests. Also we refer on special conditions which the applicant should fulfill according §2.927 to §2.948, special focus regarding modification of the equipment and availability of sample equipment for market surveillance tests. The Equipment Under Test (in this report, hereinafter referred as EUT) is a ELOshield warning system with support of UWB technology. A typical operation mode was set-up as described in chapter 3.4 according applicants instructions. Following tests have been performed to show compliance with applicable FCC Part 15, Subpart B (Unintentional Radiators) of the CFR 47 Rules, Edition 2018. 1.1. RX mode, tests overview according FCC Part 15B No. of Diagram group Test case Port References & Limits EUT set-up EUT op- mode Result FCC Standard Test limit 1 Emissions AC-Power lines conducted (0.15 to 30 MHz) AC-Power lines §15.107  Class A  Class B 1 1 Passed 3 & 4 Receiver radiated emissions Cabinet + Inter- connecting cables §15.109  Class A  Class B 1 1 Passed Remark: ...................................................... .................................................... Dipl.-Ing. Markus Ridder Dipl.-Ing. C. Lorenz Responsible for test section Responsible for test report Test Report 18-1-0029001T01a, Page 4 of 19 CETECOM_TR18_1_0029001T01a.docx 2. Administrative Data 2.1. Identification of the testing laboratory Company name: CETECOM GmbH Address: Im Teelbruch 116 45219 Essen - Kettwig Germany Responsible for testing laboratory: Volker Wittmann Deputy: Dipl.-Ing. Niels Jeß 2.2. Test location 2.2.1. Test laboratory “CTC” Company name: see chapter 2.1. Identification of the testing laboratory 2.3. Organizational items Responsible for test report and project leader: Dipl.-Ing. C. Lorenz Receipt of EUT: 2018-03-19 Date(s) of test: 2018-03-22 – 2018-10-16 Date of report: 2019-08-27 2.4. Applicant’s details Applicant’s name: ELOKON GmbH Address: Gärtnerweg 49 25436 Tornesch Germany Contact person: Mr. Thomas Linke 2.5. Manufacturer’s details Manufacturer’s name: please see Applicant details Address: please see Applicant details Test Report 18-1-0029001T01a, Page 5 of 19 CETECOM_TR18_1_0029001T01a.docx 3. Equipment under test (EUT) 3.1. TECHNICAL DATA OF MAIN EUT DECLARED BY APPLICANT Main function Pedestrian Detection and warning Device type Indoor warning system Frequency range 3100 MHz - 7000 MHz Type of modulation BPM/PSK + OOK/BPSK Number of channels 4 UWB channel EMISSION DESIGNATOR(S) IEEE 802.15.4-2011 UWB Antenna Type  Integrated  External, no RF- connector  External, separate RF-connector Power supply  power supply: 120 V AC/60 Hz EUT sample type  Production  Pre-Production  Engineering FCC label attached  yes  no 3.2. EUT: Type, S/N etc. and short descriptions used in this test report Short descrip- tion*) EUT Type S/N serial number HW hardware status SW software status EUT A S07 Stationary Module ELOshield Warning System 100868 18070046 1.1 1.1.0.4 *) EUT short description is used to simplify the identification of the EUT in this test report. 3.3. Auxiliary Equipment (AE):…

Text truncated - open the document above for the full version.

Test Setup Photos

Page 1 of 5 The test results relate only to the individual items which have been tested. This report shall not be reproduced in parts without the written approval of the testing laboratory © Copyright: All rights reserved by CETECOM Annex 4: Test setup photographs T E S T R E P O R T No.: 18-1-0029001T01a Stationary Module ELOShield Warning System 100868 FCC-ID: 2ASP7-STATM-V01 Laboratory Accreditation accredited according to DIN EN ISO/IEC 17025 CETECOM GmbH Laboratory Radio Communications & Electromagnetic Compatibility Im Teelbruch 116 • 45219 Essen • Germany Registered in Essen, Germany, Reg. No.: HRB Essen 8984 Tel.: + 49 (0) 20 54 / 95 19-954 • Fax: + 49 (0) 20 54 / 95 19-964 E-mail: [email protected] • Internet: www.cetecom.com According to: Title 47 - FCC Regulations Part 15, Subpart B §5.107, §15.109 ELOKON GmbH for Annex 4 to Test Report 18-1-0029001T01a, Page 2 of 5 CETECOM_TR18_1_0029001T01a_A4.docx Table of contents 1. TEST SETUP PHOTOGRAPHS ........................................................................................................................ 3 1.1. Conducted emission set up .............................................................................................................................. 3 1.2. Radiated Field Strength Emissions – below 1GHz .......................................................................................... 4 1.3. Radiated Field Strength Emissions – above 1GHz .......................................................................................... 5 Annex 4 to Test Report 18-1-0029001T01a, Page 3 of 5 CETECOM_TR18_1_0029001T01a_A4.docx 1. Test setup photographs 1.1. Conducted emission set up Figure 1: Stationery panel conducted AC emission set up Figure 2: Stationery panel conducted AC emission set up Annex 4 to Test Report 18-1-0029001T01a, Page 4 of 5 CETECOM_TR18_1_0029001T01a_A4.docx 1.2. Radiated Field Strength Emissions – below 1 GHz Figure 3: Radiated field set up close view – below 1 GHz Figure 4: Radiated field set up close view – below 1 GHz Annex 4 to Test Report 18-1-0029001T01a, Page 5 of 5 CETECOM_TR18_1_0029001T01a_A4.docx 1.3. Radiated Field Strength Emissions – above 1 GHz Figure 5: Radiated field set up close view – above 1 GHz Figure 6: Radiated field set up close view – above 1 GHz

Contact Information

Applicant

Thomas Linke
[email protected]+49 4122 9570-0Fax: +49 4122 957022

Test Firm

cetecom advanced GmbHGerald Schmidt
[email protected]+49 681 598 0Fax: +49 681 598 8775

Technical Specifications

#Rule PartsFrequency RangePower Output
115B--
Confidentiality
Long Term

Other Applications from ELOKON GmbH

ELOshield Verification Module - FCC ID 2ASP7-VERIFM-V01 - ELOKON GmbH
2ASP7-VERIFM-V01

ELOshield Verification Module

Jun 02, 2020

Equipment Class

JAB - Part 15 Class B Digital Device
ELOshield Pedestrian Module - FCC ID 2ASP7-PEDM-V01 - ELOKON GmbH
2ASP7-PEDM-V01

ELOshield Pedestrian Module

Mar 23, 2020

Equipment Class

UWB - Ultra Wideband Transmitter
ELOshield Antenna Module - FCC ID 2ASP7-ANTM-V01 - ELOKON GmbH
2ASP7-ANTM-V01

ELOshield Antenna Module

Mar 22, 2020

Equipment Class

UWB - Ultra Wideband Transmitter