Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
FederalCommunicationsCommission(FCC)Statement.Thisdevicecomplieswithpart15ofthe FCCRules.Operationissubjecttothefollowingtwoconditions: (1)Thisdevicemaynotcauseharmfulinterference,and (2)thisdevicemustacceptanyinterferencereceived, includinginterferencethatmaycauseundesiredoperation.Note:Thisequipmenthasbeen testedandfoundtocomplywiththelimitsforaClassBdigitaldevice,pursuanttopart15ofthe FCCRules.TheselimitsaredesignedtoprovideReasonableprotectionagainstharmful interferenceinaresidentialinstallation.Thisequipmentgenerates,usesandcanradiateradio frequencyenergyand,ifnotinstalledandusedinaccordancewiththeinstructions,maycause harmfulinterferencetoradiocommunications.However,thereisnoguaranteethatinterference willnotoccurinaparticularinstallation.Ifthisequipmentdoescauseharmfulinterferenceto radioortelevisionreception,whichcanbedeterminedbyturningtheequipmentoffandon,the userisencouragedtotrytocorrecttheinterferencebyoneormoreofthefollowing measures: •Reorientorrelocatethereceivingantenna. •Increasetheseparationbetweentheequipmentandreceiver. •Connecttheequipmentintoanoutletonacircuitdifferentfromthattowhichthereceiveris connected. •Consultthedealeroranexperiencedradio/TVtechnicianforhelp. Warning:ChangesormodificationsmadetothisdevicenotexpresslyapprovedbyXiameniLead TekCo.,Ltd.mayvoidtheFCCauthorizationtooperatethisdevice.Note:Themanufacturerisnot responsibleforanyradioorTVinterferencecausedbyunauthorizedmodificationstothis equipment.Suchmodificationscouldvoidtheuser’sauthoritytooperatetheequipment. RFexposurestatement: ThisdevicecomplieswithFCCRFradiationexposurelimitssetforthforanuncontrolled environment.Thedeviceisinstalledandoperatedwithoutrestriction.
XiameniLeadTekCo.,Ltd. Room01,Unit2101,No.50ChengyiNorthStreet,SoftwareParkPhaseIII, Xiamen,Fujian,China. OfficeofEngineeringTechnology FederalCommunicationsCommission 7435OaklandMillsRoad Columbia,MD21046 USA Date:December12,2022 Subject;RequestforConfidentiality FCCID:2ASPY-ALD-A300 ToWhomItMayConcern, PursuanttotheprovisionsoftheCommission’srulesTitle47Sections§0.457and§0.459,we arerequestingtheCommissiontowithholdthefollowingattachment(s)asconfidential documentsfrompublicdisclosureindefinitely. Thesedocumentscontaindetailedsystemandequipmentdescriptionsandareconsideredas proprietaryinformationinoperationoftheequipment.Thepublicdisclosureofthese documentsmightbeharmfultoourcompanyandwouldgivecompetitorsanunfairadvantage inthemarket. SchematicDiagram BlockDiagram PartsList OperationalDescription Tune-upProcedure SoftwareSecurityRequirementsforUNIIdevices Inadditionaltoabovementioneddocuments,inordertocomplywiththemarketingregulations inTitle47CFR§2.803andtheimportationrulesinTitle47CFR§2.1204,whileensuringthat businesssensitiveinformationremainsconfidentialuntiltheactualmarketingofnewly authorizeddevices,werequestShortTermConfidentialityofthefollowingattachment(s); ExternalPhotos TestSetupPhotos InternalPhotos UserManual For45days,pursuanttoPublicNoticeDA04-1705. OR For180dayspursuanttoKDB726920D01. Itisourunderstandingthatallmeasurementtestreports,FCCIDlabelformatand correspondenceduringthecertificationreviewprocesscannotbegrantedasconfidential documentsandthisinformationwillbeavailableforpublicreviewoncethegrantofequipment authorizationisissued. Sincerely, Signature: Name:WadeWang Title:N/A E-Mail:[email protected]
EffectiveDate:April2, 2020QSF7.6.4-8– AgentAuthorizationLetterTemplatePage1 of 1 RevisionDate:Revision:0 XiameniLead Tek Co., Ltd. Room01, Unit 2101, No.50ChengyiNorth Street,SoftwarePark PhaseIII, Xiamen,Fujian, China. Date:2022/12/12 ProductModelNumber:ALD-A300,ALD-A301,ALD-A302,ALD-A303,A3, A3s, A3Pro, A3Plus,A3X, A3Xs,A3XPro,A3XPlus,ALD-Q300,ALD-Q301,ALD-Q302,Q3, Q3s, Q3Pro, Q3Plus,Q3X, Q3Xs,Q3XPro,Q3XPlus FCC ID:2ASPY-ALD-A300 To whomit may concern, Re:ProductCertificationRepresentativeAuthorizationLetter We authorizeQAI LaboratoriesLtd. 3980 North FraserWay, BurnabyB.C. CanadaV5J 5K5 to act on our behalfon all mattersconcerningthe abovenamedequipment. This shall includethe following: Testing Approvalapplicationsand procedures We declare that ORGANIZATION. is allowed to forward all information related to the approval project to the applied certification body and to the notification entities and to discuss any issues concerning the approval application. Any and all acts carried out by ORGANIZATION. on our behalf shall have the same effect as acts of our own. By: ContactListedon FCC Wesbite Title: N/A Email: [email protected] Telephone:+86-4008550 520 On behalfof: XiameniLead Tek Co., Ltd.
XiameniLeadTekCo.,Ltd. Room01,Unit2101,No.50ChengyiNorthStreet,SoftwareParkPhaseIII,Xiamen,Fujian,China. SeriesModelsDescription Towhomitmayconcern: Thedevice(ProductName:PeriPageMiniPrinter)ModelsName:ALD-A300, ALD-A301,ALD-A302,ALD-A303,A3,A3s,A3Pro,A3Plus,A3X,A3Xs,A3XPro, A3XPlus,ALD-Q300,ALD-Q301,ALD-Q302,Q3,Q3s,Q3Pro,Q3Plus,Q3X,Q3Xs, Q3XPro,Q3XPlushavesameelectrical,PCBandBOM,onlythemodel’sname andcolouraredifferentformarketingrequirements. Sincerely, WadeWang Phone:+86-4008550520 e-mail:[email protected] Dated:12/12/2022
NOTE:1.Thereportisinvalidwhenthereisnotheapproversignatureandthespecialstampfortestreport.2.Thetestreport shallnotbereproducedexceptinfullwithoutpriorwrittenpermissionofthecompany.3.Thereportcopyisinvalidwhenthereis nothespecialstampfortestrepor.4.Thealteredreportisinvalid.5.Theentrusttestisresponsibilityforthereceivedsample only Kehu-Morlab TestLaboratory XIAMENMORLABCOMMUNICATIONSTECHNOLOGYCo.,Ltd. Unit101,No.1732GangzhongRoad,XiamenArea,PilotFreeTradeZone(Fujian),P.R.China Tel:+865925612050 Fax:+865925612095 REPORTNo.:XM20060056W03 TESTREPORT MANUFACTURER:XiamenIleadTekCo.,Ltd. PRODUCTNAME:2.4G_IFA MODELNAME:ANT001 BRANDNAME:PeriPage STANDARD(S): IEEE-149-1979-R2003 RECEIPTDATE: 2020.7.20 TESTDATE:2020.7.20 ISSUEDATE:2020.7.20 Editedby: Pengfuwei(Testengineer) Reviewby: ElvisWang(Auditor) Approvedby: AnneLiu(Supervisor) Page 1 0f11 Kehu-Morlab TestLaboratory XIAMENMORLABCOMMUNICATIONSTECHNOLOGYCo.,Ltd. Unit101,No.1732GangzhongRoad,XiamenArea,PilotFreeTradeZone(Fujian),P.R.China Tel:+865925612050 Fax:+865925612095 REPORTNo.:XM20060056W03 DIRECTORY 1.Technicalinformation·····················································································3 1.1EquipmentUnderTest(EUT)Description························································3 1.2AntennalayoutandImplementation:······························································4 1.3TestingLaboratoryInformation·····································································5 1.4TestStandardandResults ············································································ 5 1.5TestEquipmentandSoftware ········································································ 6 1.6EnvironmentalConditions ············································································· 6 2.Testresults ···································································································· 7 2.1AntennaGain,Efficiency,Pattern ··································································· 7 AnnexAphotographsoftestsetup····································································11 ChangeHistory VersionDateReasonforchange 1.02020-07-20Firstedition Page20f11 Kehu-Morlab TestLaboratory XIAMENMORLABCOMMUNICATIONSTECHNOLOGYCo.,Ltd. Unit101,No.1732GangzhongRoad,XiamenArea,PilotFreeTradeZone(Fujian),P.R.China Tel:+865925612050 Fax:+865925612095 REPORTNo.:XM20060056W03 1.Technicalinformation 1.1EquipmentUnderTest(EUT)Description EUTType................................: N/A SampleNo.............................:N/A HardwareVersion.................:N/A SoftwareVersion..................:N/A Applicant................................:XiamenIleadTekCo.,Ltd. Manufacturer.........................:XiamenIleadTekCo.,Ltd. StandardandFrequency Band.........................................: 2400MHz-2483.5MHz TestChannel..........................:N/A ModulationType...................:N/A AntennaType........................:PCBon-board AntennaConnector.............:N/A PowerSupply........................:N/A Note1:Foramoredetaileddescription,pleaserefertoSpecificationorUser’sManualsuppliedby theapplicantand/ormanufacturer. Page30f11 Kehu-Morlab TestLaboratory XIAMENMORLABCOMMUNICATIONSTECHNOLOGYCo.,Ltd. Unit101,No.1732GangzhongRoad,XiamenArea,PilotFreeTradeZone(Fujian),P.R.China Tel:+865925612050 Fax:+865925612095 REPORTNo.:XM20060056W03 1.2AntennalayoutandImplementation: Figure1:AntennaDimensions L1 3.94mm L2 2.70mm L3 5.00mm L4 2.64mm L5 2.00mm L6 4.90mm W1 0.90mm W2 0.50mm D1 0.50mm D2 0.30mm D3 0.30mm D4 0.50mm D5 1.40mm D6 1.70mm Table1:AntennaDimensions Page40f11 Kehu-Morlab TestLaboratory XIAMENMORLABCOMMUNICATIONSTECHNOLOGYCo.,Ltd. Unit101,No.1732GangzhongRoad,XiamenArea,PilotFreeTradeZone(Fujian),P.R.China Tel:+865925612050 Fax:+865925612095 REPORTNo.:XM20060056W03 1.3TestingLaboratoryInformation 1.IdentificationoftheResponsibleTestingLaboratory LaboratoryName: Kehu-MorlabTestLaboratory LaboratoryAddress:Unit101,No.1732GangzhongRoad,XiamenArea,PilotFree TradeZone(Fujian)P.R.China Telephone: +865925612050 Facsimile: +865925612095 2.IdentificationoftheResponsibleTestingLocation 1.4TestStandardandResults Thereportistestedaccordingtothefollowingstandard: NoStandardNo.StandardName 1 IEEE-149-1979-R2003 StandardTestProceduresforAntennas Testitemsandtheresultsareasbellow: NoTestFrequencyBandTestItemResult 12400MHz ~ 2483.5MHzGainN/A 22400MHz ~ 2483.5MHzEfficiencyN/A 32400MHz ~ 2483.5MHzPatternN/A Name: Kehu-MorlabTestLaboratory Address: Unit101,No.1732GangzhongRoad,XiamenArea,PilotFree TradeZone(Fujian)P.R.China Page50f11 Kehu-Morlab TestLaboratory XIAMENMORLABCOMMUNICATIONSTECHNOLOGYCo.,Ltd. Unit101,No.1732GangzhongRoad,XiamenArea,PilotFreeTradeZone(Fujian),P.R.China Tel:+865925612050 Fax:+865925612095 REPORTNo.:XM20060056W03 1.5TestEquipmentandSoftware NoEquipmentType(Version)SupplierCal.DueDate 1 OTATestsystem EMQuest1.11Build 7570 ETS/U.S.A / 2 NetworkAnalyzerAglientE5071C keysight/U.S. A 2021-03-11 3 FullyAnechoic Chamber 4m×4m×4mETS/U.S.A2022-05-31 1.6EnvironmentalConditions Recordtherangeoftestenvironmentduringthetest: Ambienttemperature(°C):15-35 Relativehumidity(%):30-60 Atmospherepressure(kPa):86-106 Page60f11 Kehu-Morlab TestLaboratory XIAMENMORLABCOMMUNICATIONSTECHNOLOGYCo.,Ltd. Unit101,No.1732GangzhongRoad,XiamenArea,PilotFreeTradeZone(Fujian),P.R.China Tel:+865925612050 Fax:+865925612095 REPORTNo.:XM20060056W03 2.Testresults 2.1AntennaGain,Efficiency,Pattern 2.1.1TestProcedure: ThemeasuredEUTrotates0~180degreesaroundtheθaxis.Themeasured antennaissampledalongtheΦaxisof0~360from15degreestoameasuringstep,and themeasuredvalueisreadautomatically.Theantennagain,efficiency,patternis measured 2.1.2TestResult: MaxGain:-4.73dBi No. Test Frequency (MHz) GainTest Value (dBi) Efficiency testvalue (%) Antenna pattern Result 12400-4.8015.56 Phi=0 Phi=90 Theta=90 N/A 22402-4.8915.66N/A 32404-4.9015.52N/A 42406-4.7315.49N/A 52408-4.7915.44N/A Master computer PathSwitcher NetworkAnalyzer measured antenna Fully Anechoic Chamb…
Text truncated - open the document above for the full version.
FCCID:2ASPY-ALD-A300Page 1 of 3 ReportNo.:CTL2211162011-WF ExternalPhotosofEUT FCCID:2ASPY-ALD-A300Page 2 of 3 ReportNo.:CTL2211162011-WF FCCID:2ASPY-ALD-A300Page 3 of 3 ReportNo.:CTL2211162011-WF
FCCID:2ASPY-ALD-A300Page 1 of 1 ReportNo.:CTL2211162011-WF FCCIDLabelInformation Labellocation: PeriPageMiniPrinter Model:ALD-A300 FCCID:2ASPY-ALD-A300
FCCID:2ASPY-ALD-A300Page 1 of 3 ReportNo.:CTL2211162011-WF InternalPhotosofEUT FCCID:2ASPY-ALD-A300Page 2 of 3 ReportNo.:CTL2211162011-WF Bluetooth Antenna FCCID:2ASPY-ALD-A300Page 3 of 3 ReportNo.:CTL2211162011-WF
FCCID:2ASPY-ALD-A300Page 1 of 1 ReportNo.:CTL2211162011-WF RFExposureLetter Accordingto447498D01GeneralRFExposureGuidancev05The1 ‐ gand10 ‐ g SARtest exclusionthresholdsfor100MHzto6GHzattestseparationdistances ≤ 50mm aredeterminedby:[(max.powerofchannel,includingtune ‐ uptolerance,mW)/(min. testseparationdistance,mm)] · [ √ f(GHz)] ≤ 3.0for1 ‐ gSARand ≤ 7.5for10 ‐ gextremitySAR,where f(GHz)istheRFchanneltransmitfrequencyinGHz PoweranddistanceareroundedtothenearestmWandmmbeforecalculation Theresultisroundedtoonedecimalplaceforcomparison BluetoothBDR: pt=3.82dBm=2.41mWat2441MHz So(2.41mW/5mm)x √ 2.441GHz=0.7530<3 BluetoothBLE: pt=3.77dBm=2.38mWat2440MHz So(2.38mW/5mm)x √ 2.440GHz=0.7443<3 ThenSARevaluationisnotrequired
ShenzhenCTLTestingTechnologyCo.,Ltd. Tel:+86-755-89486194E-mail:[email protected] 1.Bandwidth 1.1OBW 1.1.1TestResult Mode TX Type Frequency (MHz) ANT 99%OccupiedBandwidth(MHz) Verdict Result 1MSISO 240211.219Pass 244011.194Pass 248011.164Pass V1.0Page2of19ReportNo.:CTL2211162011-WF02 1.1.2TestGraph 1M_LCH_2402MHz_Ant1_NTNV 1M_MCH_2440MHz_Ant1_NTNV V1.0Page3of19ReportNo.:CTL2211162011-WF02 1M_HCH_2480MHz_Ant1_NTNV V1.0Page4of19ReportNo.:CTL2211162011-WF02 1.26dBBW 1.2.1TestResult Mode TX Type Frequency (MHz) ANT 6dBBandwidth(MHz) Verdict ResultLimit 1MSISO 240210.795>=0.5Pass 244010.803>=0.5Pass 248010.816>=0.5Pass V1.0Page5of19ReportNo.:CTL2211162011-WF02 1.2.2TestGraph 1M_LCH_2402MHz_Ant1_NTNV 1M_MCH_2440MHz_Ant1_NTNV V1.0Page6of19ReportNo.:CTL2211162011-WF02 1M_HCH_2480MHz_Ant1_NTNV V1.0Page7of19ReportNo.:CTL2211162011-WF02 2.MaximumConductedOutputPower 2.1Power 2.1.1TestResult Mode TX Type Frequency (MHz) MaximumPeakConductedOutputPower(dBm) Verdict ANT1Limit 1MSISO 24023.36<=30Pass 24403.77<=30Pass 24803.41<=30Pass Note1:AntennaGain:Ant1:-4.73dBi; V1.0Page8of19ReportNo.:CTL2211162011-WF02 2.1.2TestGraph 1M_LCH_2402MHz_Ant1_NTNV 1M_MCH_2440MHz_Ant1_NTNV V1.0Page9of19ReportNo.:CTL2211162011-WF02 1M_HCH_2480MHz_Ant1_NTNV V1.0Page10of19ReportNo.:CTL2211162011-WF02 3.MaximumPowerSpectralDensity 3.1PSD 3.1.1TestResult Mode TX Type Frequency (MHz) MaximumPSD(dBm/3kHz) Verdict ANT1Limit 1MSISO 2402-13.45<=8Pass 2440-13.17<=8Pass 2480-13.16<=8Pass Note1:AntennaGain:Ant1:-4.73dBi; V1.0Page11of19ReportNo.:CTL2211162011-WF02 3.1.2TestGraph 1M_LCH_2402MHz_Ant1_NTNV 1M_MCH_2440MHz_Ant1_NTNV V1.0Page12of19ReportNo.:CTL2211162011-WF02 1M_HCH_2480MHz_Ant1_NTNV V1.0Page13of19ReportNo.:CTL2211162011-WF02 4.UnwantedEmissionsInNon-restrictedFrequencyBands 4.1Ref 4.1.1TestResult Mode TX Type Frequency (MHz) ANT LevelofReference (dBm) 1MSISO 240211.96 244012.36 248011.81 Note1:RefertoFCCPart15.247(d)andANSIC63.10-2013,thechannelcontainsthemaximumPSDlevelwasusedto establishthereferencelevel. V1.0Page14of19ReportNo.:CTL2211162011-WF02 4.1.2TestGraph 1M_LCH_2402MHz_Ant1_NTNV 1M_MCH_2440MHz_Ant1_NTNV V1.0Page15of19ReportNo.:CTL2211162011-WF02 1M_HCH_2480MHz_Ant1_NTNV V1.0Page16of19ReportNo.:CTL2211162011-WF02 4.2CSE 4.2.1TestResult Mode TX Type Frequency (MHz) ANT LevelofReference (dBm) Limit (dBm) Verdict 1MSISO 240212.36-17.64Pass 244012.36-17.64Pass 248012.36-17.64Pass Note1:RefertoFCCPart15.247(d)andANSIC63.10-2013,thechannelcontainsthemaximumPSDlevelwasusedto establishthereferencelevel. V1.0Page17of19ReportNo.:CTL2211162011-WF02 4.2.2TestGraph 1M_LCH_2402MHz_Ant1_NTNV 1M_LCH_2402MHz_Ant1_NTNV V1.0Page18of19ReportNo.:CTL2211162011-WF02 1M_MCH_2440MHz_Ant1_NTNV 1M_HCH_2480MHz_Ant1_NTNV V1.0Page19of19ReportNo.:CTL2211162011-WF02 1M_HCH_2480MHz_Ant1_NTNV
ShenzhenCTLTestingTechnologyCo.,Ltd. Tel:+86-755-89486194E-mail:[email protected] TESTREPORT FCCPART15.247 ReportReferenceNo.....................:CTL2211162011-WF02 Compiledby: (position+printedname+signature) HappyGuo (Fileadministrators) Testedby: (position+printedname+signature) GaryGao (TestEngineer) Approvedby: (position+printedname+signature) IvanXie (Manager) ProductName.................................: PeriPageMiniPrinter Model/Typereference....................:ALD-A300 ListModel(s)....................................: ALD-A301,ALD-A302,ALD-A303,A3,A3s,A3Pro,A3Plus,A3X, A3Xs,A3XPro,A3XPlus,ALD-Q300,ALD-Q301,ALD-Q302,Q3, Q3s,Q3Pro,Q3Plus,Q3X,Q3Xs,Q3XPro,Q3XPlus TradeMark.......................................: PeriPage FCCID ............................................... : 2ASPY-ALD-A300 Applicant’sname...........................: XiameniLeadTekCo.,Ltd. Addressofapplicant.....................: Room01,Unit2101,No.50ChengyiNorthStreet,SoftwarePark PhaseIII,Xiamen,Fujian,China. TestFirm...........................................: ShenzhenCTLTestingTechnologyCo.,Ltd. AddressofTestFirm.....................: Floor1-A,BaishaTechnologyPark,No.3011,ShahexiRoad, NanshanDistrict,Shenzhen,China518055 Testspecification...........................: Standard............................................:FCCPart15.247:Operationwithinthebands902-928MHz, 2400-2483.5MHzand5725-5850MHz. TRFOriginator..................................: ShenzhenCTLTestingTechnologyCo.,Ltd. MasterTRF ....................................... :Dated2011-01 Dateofreceiptoftestitem .......... : Nov.25,2022 DateofTestDate............................: Nov.25,2022-Dec.05,2022 DateofIssue .................................... : Dec.05,2022 Result................................................: Pass ShenzhenCTLTestingTechnologyCo.,Ltd.Allrightsreserved. Thispublicationmaybereproducedinwholeorinpartfornon-commercialpurposesaslongasthe ShenzhenCTLTestingTechnologyCo.,Ltd.isacknowledgedascopyrightownerandsourceofthe material.ShenzhenCTLTestingTechnologyCo.,Ltd.takesnoresponsibilityforandwillnotassume liabilityfordamagesresultingfromthereader'sinterpretationofthereproducedmaterialduetoits placementandcontext. V1.0Page2of28ReportNo.:CTL2211162011-WF02 TESTREPORT TestReportNo.:CTL2211162011-WF02 Dec.05,2022 Dateofissue EquipmentunderTest: PeriPageMiniPrinter SampleNo:CTL221116201-1-S001 Model/Type: ALD-A300 ListedModels : ALD-A301,ALD-A302,ALD-A303,A3,A3s,A3Pro,A3Plus, A3X,A3Xs,A3XPro,A3XPlus,ALD-Q300,ALD-Q301, ALD-Q302,Q3,Q3s,Q3Pro,Q3Plus,Q3X,Q3Xs,Q3XPro, Q3XPlus Applicant: XiameniLeadTekCo.,Ltd. Address : Room01,Unit2101,No.50ChengyiNorthStreet,Software ParkPhaseIII,Xiamen,Fujian,China. Manufacturer: XiameniLeadTekCo.,Ltd. Address : Room01,Unit2101,No.50ChengyiNorthStreet,Software ParkPhaseIII,Xiamen,Fujian,China. TestresultPass* *Intheconfigurationtested,theEUTcompliedwiththestandardsspecifiedpage5. Thetestresultspresentedinthisreportrelateonlytotheobjecttested. Thisreportshallnotbereproduced,exceptinfull,withoutthewrittenapprovaloftheissuingtesting laboratory. Thedevice(ProductName:PeriPageMiniPrinter)ModelsName:ALD-A300,ALD-A301,ALD-A302, ALD-A303,A3,A3s,A3Pro,A3Plus,A3X,A3Xs,A3XPro,A3XPlus,ALD-Q300,ALD-Q301,ALD-Q302,Q3, Q3s,Q3Pro,Q3Plus,Q3X,Q3Xs,Q3XPro,Q3XPlushavesameelectrical,PCBandBOM,onlythemodel’ snameandcolouraredifferentformarketingrequirements. V1.0Page3of28ReportNo.:CTL2211162011-WF02 **ModifiedHistory** RevisionsDescriptionIssuedDataReportNo.Remark Version1.0InitialTestReportRelease2022-12-05CTL2211162011-WF02TracyQi V1.0Page4of28ReportNo.:CTL2211162011-WF02 TableofContentsPage 1.SUMMARY.......................................................................................................................................................................5 1.1.TESTSTANDARDS............................................................................................................................................................5 1.2.TESTDESCRIPTION...............................................................................................................................................................5 1.3.TESTFACILITY.....................................................................................................................................................................6 1.4.STATEMENTOFTHEMEASUREMENTUNCERTAINTY.....................................................................................................................6 2.GENERALINFORMATION.................................................................................................................................................8 2.1.ENVIRONMENTALCONDITIONS...............................................................................................................................................8 2.2.GENERALDESCRIPTIONOFEUT.............................................................................................................................................8 2.3.DESCRIPTIONOFTESTMODESANDTESTFREQUENCY................................................................................................................9 2.4.EQUIPMENTSUSEDDURINGTHETEST...................................................................................................................................10 2.5.RELATEDSUBMITTAL(S)/GRANT(S)....................................................................................................................................10 2.6.MODIFICATIONS................................................................................................................................................................10 3.TESTCONDITIONSANDRESULTS...................................................................................................................................11 3.1.CONDUCTEDEMISSIONSTEST..............................................................................................................................................11 3.2.RADI…
Text truncated - open the document above for the full version.
FCCID:2ASPY-ALD-A300Page 1 of 2 ReportNo.:CTL2211162011-WF TestSetupPhotosoftheEUT FCCID:2ASPY-ALD-A300Page 2 of 2 ReportNo.:CTL2211162011-WF
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 2.40 mW |

PeriPage Tattoo Transfer Printer
Equipment Class
DTS - Digital Transmission SystemPeriPage Numeric Label Maker
Equipment Class
DSS - Part 15 Spread Spectrum TransmitterPeriPage Voice Label Printer
Equipment Class
DTS - Digital Transmission System
PeriPage Translation Pen
Equipment Class
DTS - Digital Transmission System
PeriPage Mini Printer
Equipment Class
DTS - Digital Transmission System