
Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
SERIES Smart Cordless Hard Floor Cleaner Bedienungsanleitung Instruction Manual Manual De Uso Mode D’emploi Manuale D’istruzioni leaner 23 EN CONTENTS Important Safety Instructions ............................................................. 24 Overview .............................................................................................. 28 Accessories .......................................................................................... 30 Assembly ............................................................................................. 31 Operation ............................................................................................ 32 Maintenance ....................................................................................... 38 Specifications ...................................................................................... 42 Troubleshooting .................................................................................. 43 Warranty .............................................................................................. 44 EN 24 Important Safety Instructions SAVE THESE INSTRUCTIONS Household use only. When using an electrical appliance, basic precautions should always be followed, including the following: READ ALL INSTRUCTIONS BEFORE USING (THIS APPLIANCE). Failure to follow the warnings and instructions may result in electric shock, fire and/or serious injury. WARNING – To reduce the risk of fire, electric shock, or injury: 1. Use only indoors, on non-carpeted floor surfaces such as vinyl, tile, sealed wood, etc. Be careful not to run over loose objects or edges of area rugs. Stalling the brush may result in premature belt failure. 2. Do not allow to be used as a toy. Close attention is necessary when used by or near children, pets or plants. 3. Use only as described in this manual. Use only manufacturer’s recommended attachments. 4. Do not use with a damaged cord or plug. If appliance has been dropped, damaged, left outdoors, dropped into water, or is not working as it should, return it to a service center. 5. Do not handle charger, including charger plug, and charger terminals with wet hands. 6. Do not put any object into openings. Do not use with any opening blocked; keep free of dust, lint, hair, and anything that may reduce air flow. 7. Keep hair, loose clothing, fingers, and all parts of your body away from openings and moving parts. 8. Use extra care when cleaning on stairs. 9. Do not use to pick up flammable or combustible liquids, such as gasoline, or use in areas where they may be present. 10. Do not pick up anything that is burning or smoking, such as cigarettes, matches, or hot ashes. 11. Do not use without filter. 12. Prevent unintentional activation. Ensure the switch is in the off-position before picking up or carrying the appliance. Carrying the appliance with your finger on the switch or energizing appliance that have the switch on invites accidents. 13. Always switch off the appliance before making any adjustments, changing accessories, or storing the appliance. Such preventive safety measures reduce the risk of starting the appliance accidentally. 14. Recharge only with the charger specified by Tineco. A charger that is suitable for one type of battery pack may create a risk of fire when used with another battery pack. 15. Use appliances only with specifically designated Tineco battery packs. Use of any other battery packs may create a risk of injury and fire. 16. Under abusive conditions, liquid may be ejected from the battery; avoid contact. If contact accidentally occurs, flush with water. If liquid comes into eye contact, seek medical help. Liquid ejected from the battery may cause irritation or burns. EN 25 17. Do not use a battery pack or appliance that is damaged or modified. Damaged or modified batteries may exhibit unpredictable behavior resulting in fire, explosion or risk of injury. 18. Do not expose a battery pack or appliance to fire or excessive temperature. Exposure to fire or temperature above 266°F (130°C) may cause an explosion. 19. Follow all charging instructions and do not charge the battery pack or appliance outside of the temperature range specified in the instructions. Charging improperly or at temperatures outside of the specified range may damage the battery and increase the risk of fire. 20. Have servicing performed by a qualified repair person using only identical replacement parts. This will ensure that the safety of the product is maintained. 21. Do not modify or attempt to repair the appliance or the battery pack except as indicated in the instructions for use and care. 22. Always turn off this appliance before connecting or disconnecting the motorized nozzle. 23. Do not charge or store the appliance outdoors or inside the car. Only charge, store or use the battery in a dry indoor area where the temperature is higher than 39.2°F (4°C) but lower than 104°F (40°C). The charger is for indoor use only. 24. Do not use to pick up ultrafine particles, such as lime, cement, sawdust, gypsum powder, or ashes. 25. Do not use to pick up sharp objects, such as metallic nails, pieces of glass, metal paper clips, or pins. 26. Do not use to pick up hazardous material and chemicals, such as solvent, drain cleaner, strong acids, or strong alkali. 27. Stop using immediately if the appliance is overheating, making unusual noises, producing unusual odors, performing low suction, or leaks electricity. 28. Turn cleaner OFF and disconnect from electrical outlet for long-term storage. 29. Always clean the Dirty Water Tank after each use to avoid potential blockage, which may lead to low suction power, motor overheating, or reduce the service life of the appliance. 30. Store appropriately indoors in a dry place after use. 31. Do not place or submerge appliance in standing water or try to clean flooded areas. 32. All data and technical instructions of this manual are based on results from lab tests of Tineco or desi…
Text truncated - open the document above for the full version.
FR 68 SOMMAIRE Consignes de sécurité importantes .................................................. 69 Description .......................................................................................... 72 Accessoires .......................................................................................... 74 Assemblage ........................................................................................ 75 Fonctionnement ................................................................................. 76 Entretien .............................................................................................. 82 Spécifications ...................................................................................... 86 Guide de dépannage ......................................................................... 87 Garantie ............................................................................................... 88 FR 69 Consignes de sécurité importantes CONSERVEZ CES INSTRUCTIONS Usage domestique exclusivement. Lorsque vous utilisez un appareil électrique, veuillez respecter des précautions de sécurité élémentaires, incluant les suivantes : LISEZ TOUTES LES INSTRUCTIONS AVANT L’UTILISATION (DE CET APPAREIL). Ne pas respecter les consignes de sécurité et les instructions peut provoquer un choc électrique, un incendie et/ou des blessures graves. AVERTISSEMENT – Afin de réduire le risque d’incendie, de choc électrique ou de blessures corporelles : 1. Veillez à uniquement utiliser l’appareil en intérieur, sur des sols dépourvus de moquette, par exemple en vinyle, en carrelage, en parquet, etc. Veillez à ne pas passer sur des objets non fixés ni sur les bords de tapis. Le blocage de la brosse peut entraîner une défaillance prématurée de la courroie. 2. Veillez à ce que cet appareil ne soit pas utilisé comme un jouet. Une attention particulière est nécessaire lorsque l’aspirateur est utilisé près d’enfants, d’animaux domestiques ou de plantes. 3. Utilisez l’appareil uniquement de la manière décrite dans ce manuel. Utilisez exclusivement les accessoires recommandés par le constructeur. 4. N’utilisez pas l’appareil si son câble d’alimentation ou sa prise est endommagé(e). Si l’appareil est tombé, est endommagé, a été laissé à l’extérieur ou en contact avec de l’eau ou ne fonctionne pas correctement, retournez-le à un centre d’entretien. 5. Ne manipulez pas le chargeur, y compris la prise et/ou les bornes du chargeur avec les mains mouillées. 6. N’insérez aucun objet dans les ouvertures. N’utilisez pas l’appareil si l’une des ouvertures est obstruée. Veillez à éviter l’accumulation dans les ouvertures de tout ce qui pourrait diminuer le flux d’air (poussières, peluches, poils, etc.). 7. Gardez les cheveux, les vêtements amples, les doigts et autres parties du corps éloignés des ouvertures et des pièces en mouvement. 8. Soyez particulièrement vigilant(e) en passant l’aspirateur dans les escaliers. 9. N’utilisez pas cet appareil pour aspirer des liquides combustibles ou inflammables, comme l’essence, et ne passez pas l’aspirateur dans une pièce où se trouvent de tels liquides. 10. Ne passez en aucun cas l’aspirateur sur des objets brûlants ou incandescents, comme des cigarettes, des allumettes ou des cendres chaudes. 11. Ne faites pas fonctionner cet appareil sans le filtre. 12. Évitez la mise en marche accidentelle. Vérifiez que l’interrupteur marche/arrêt est en position d’arrêt avant de saisir l’appareil ou de le porter. Transporter l’appareil avec un doigt sur l’interrupteur ou le brancher sur une alimentation électrique alors que son interrupteur est en position de marche favorise les accidents. 13. Éteignez toujours l’appareil avant d’effectuer un réglage, de changer un accessoire ou de ranger l’appareil. Ces mesures de sécurité permettent de réduire les risques de démarrage accidentel de l’outil. 14. Rechargez uniquement l’appareil avec le chargeur spécifié par Tineco. Un chargeur adapté à un seul type de batterie peut présenter un risque d’incendie s’il est utilisé avec une batterie différente. FR 70 15. Utilisez cet appareil uniquement avec des batteries Tineco spécialement conçues pour cet usage. L’utilisation de toute autre batterie peut créer un risque de blessures et d’incendie. 16. Si la batterie est soumise à des conditions abusives, du liquide peut s’en échapper. Évitez tout contact avec ce liquide. En cas de contact accidentel, rincez à grande eau. Si du liquide entre en contact avec les yeux, consultez un médecin. Le liquide qui s’échappe de la batterie peut provoquer des irritations et des brûlures. 17. N’utilisez pas l’appareil si la batterie ou l’appareil lui-même est endommagé ou modifié. Les batteries modifiées ou endommagées peuvent produire un fonctionnement imprévisible pouvant provoquer un incendie, une explosion ou un risque de blessure. 18. N’exposez pas la batterie ou l’appareil à des flammes ou à une température excessive. L’exposition au feu ou à des températures supérieures à 130 °C (266 °F) peut provoquer une explosion. 19. Respectez toutes les instructions de charge et ne rechargez pas la batterie ou l’appareil quand la température ambiante est au-delà de la plage spécifiée dans les instructions. Une recharge incorrecte ou recharger une batterie sous des températures hors de la plage spécifiée peut endommager la batterie et accroître le risque d’incendie. 20. Faites réparer votre appareil par un réparateur qualifié qui ne devra utiliser que des pièces de rechange identiques. Cet appareil contient des batteries qui ne peuvent être remplacées que par des personnes qualifiées. Cela permettra de garantir une utilisation sûre de l’appareil. 21. Ne modifiez pas et n’essayez pas de réparer l’appareil ou la batterie sauf comme indiqué dans les instructions d’utilisation et d’entretien. 22. Éteignez toujours cet appareil avant de brancher ou de débrancher l’embout motorisé. 23. Ne chargez et ne rangez pas l’appareil en plein air ou à l’intérieur d’une voiture. Charg…
Text truncated - open the document above for the full version.
Addres Confir m We, Ec o The pro And mo T L c m O ss: NO 108 mation Letter ovacs Robo oduct: Smart odel No.: FW These mod Layout, com construction marketing c (Signature) On behalf o E SHI HU RD r otics Co Ltd t Cordless H W05US0001 dels have t mponents a n with FW05 channel and of: Ecovacs Ro D (W) WU Z Hard Floor C ,FW05CA0 the same t and compon 5US0001.Th d sale count obotics Co HONG ZON Cleaner 0001, FW05U echnical co nent layout, he differenc ry o Ltd NE, SUZHO US0201 onstruction all electri c ce lies only t OU JIANGSU including c cal construc the model n U 215128Ch circuit diagr ction and m number ,pro hina ram, PCB mechanical oduct color,
Co m Ad d 215 Pro d Mo d Prod We to a c equi We app r disc MiC Sig n Nam Title Com mpany: Eco dress: NO 1 128China duct Name del Number duct Descr authorize M ct on our be ipment. declare tha roval and ce cuss any iss OM Labs o nature: me: Yo e: Ce mpany: Ec ovacs Robo 108 SHI HU e: Smart Co r(s): FW05U ription: Sm MiCOM Labs ehalf on all m t MiCOM La ertification o ues concer n our behal onghua Huang ertification Eng covacs Robo Ecovac Agent otics Co Lt RD (W) W U ordless Ha US0001, FW art Cordles s Inc., 575 B matters con abs Inc. is a of equipmen ning the app f shall have g gineer otics Co Ltd cs Robotic Autho d U ZHONG Z rd Floor Cl W05CA0001 ss Hard Flo Boulder Cou ncerning the allowed to fo nt to the reg proval appli e the same e cs Co Ltd rization ZONE, SUZ leaner 1, FW05US0 oor Cleaner urt, Pleasan e certification orward all in gulatory age ication. Any effect as act D n ZHOU JIAN 0201 r nton, Califor n of above n nformation r encies as req y and all acts ts of our ow Date: 2020 GSU rnia 94566, named elated to th e quired and t s carried ou wn. 0/01/11 USA, e to ut by
Office o Federal 7435 O a Columb USA Subject FCC ID To Wh o Pursuan are requ docume These d propriet might be In addit i in Title 4 busines authoriz For 4 O For 1 It is our corresp o docume authoriz Sincere Signatu Name: Y Title: Ce of Engineerin Communic akland Mills bia, MD 2104 ; Request fo : 2ASWB-F om It May C nt to the pro uesting the ents from pu documents c tary informa e harmful to Schema Block Di Parts Lis Operatio Tune-up FCC Sof ional to abo 47 CFR §2. ss sensitive zed devices External Test Set Internal User Ma 45 days, pu OR 180 days pu understand ondence du ents and this zation is issu ly, re : Yonghua Hua ertification Eng ng Technolo cations Com s Road 46 or Confiden S3 oncern, ovisions of th Commissio ublic disclos contain deta ation in oper o our compa tic Diagram agram st onal Descrip p Procedure ftware Secu ove mention 803 and th e information , we reque s Photos tup Photos Photos anual rsuant to P u ursuant to K ding that all uring the cer s informatio ued. ng gineer Ecovacs R ogy mmission tiality he Commis n to withhol sure indefini ailed system ration of the any and wou m ption urity Require ed docume e importatio remains c o st Short Ter ublic Notice KDB 726920 measureme rtification re on will be av Robotics Co sion’s rules ld the follow tely. m and equip equipment uld give com ements for U nts, in orde n rules in T onfidential u m Confiden e DA 04-170 0 D01. ent test repo eview proces vailable for p o Ltd s Title 47 Se wing attachm pment descr . The public mpetitors an UNII device r to comply itle 47 CF R until the actu ntiality of the 05. orts, FCC ID ss cannot b public review D ections §0.4 ment(s) as c riptions and c disclosure n unfair adva es with the m a R §2.1204, w ual marketin e following a D label form be granted a w once the g Date: 2020/0 57 and §0.4 confidential are consid e of these do antage in th arketing reg while ensurin ng of newly attachment( mat and as confident grant of equ 01/07 459, we ered as ocuments he market. gulations ng that s); tial uipment
UL-CCIC COMPANY LIMITED This report shall not be reproduced except in full, without the written approval of UL-CCIC COMPANY LIMITED. Appendix I External Photographs MODEL NUMBER: FW05US0001 FCC ID: 2ASWB-FS3 IC: 24918-FS3 Page 2 of 4 UL-CCIC COMPANY LIMITED This report shall not be reproduced except in full, without the written approval of UL-CCIC COMPANY LIMITED. . . All View of EUT Detail View of Adapter FCC ID: 2ASWB-FS3 IC: 24918-FS3 Page 3 of 4 UL-CCIC COMPANY LIMITED This report shall not be reproduced except in full, without the written approval of UL-CCIC COMPANY LIMITED. . . Back View of EUT FCC ID: 2ASWB-FS3 IC: 24918-FS3 Page 4 of 4 UL-CCIC COMPANY LIMITED This report shall not be reproduced except in full, without the written approval of UL-CCIC COMPANY LIMITED. . . Left View of EUT Right View of EUT
55mm 37mm Smart Cordless Hard Floor Cleaner Model: FW05CA0001 Rating Power: 220W FCC ID: 2ASWB-FS3 IC: 24918-FS3 Voltage: 21.6V Made in China2019.01 IPX4 For use only with TINECO charger YLJXIIBY-T260100 Utiliser seulement TINECO chargeur YLJXIIBY-T260100 Pantone 427c Pantone 427c
55mm 37mm Smart Cordless Hard Floor Cleaner Model: FW05US0001 Rating Power: 220W FCC ID: 2ASWB-FS3 IC: 24918-FS3 Voltage: 21.6V Made in China2019.01 IPX4 For use only with TINECO charger YLJXIIBY-T260100 Utiliser seulement TINECO chargeur YLJXIIBY-T260100 Pantone 427c Pantone 427c
55mm 37mm Smart Cordless Hard Floor Cleaner Model: FW05US0201 Rating Power: 220W FCC ID: 2ASWB-FS3 IC: 24918-FS3 Voltage: 21.6V Made in China2019.01 IPX4 For use only with TINECO charger YLJXIIBY-T260100 Utiliser seulement TINECO chargeur YLJXIIBY-T260100 Pantone 427c Pantone 427c
Appendix II Internal Photographs MODEL NUMBER: FW05US0001 FCC ID: 2ASWB-FS3 IC: 24918-FS3 Page 2 of 10 UL-CCIC COMPANY LIMITED This report shall not be reproduced except in full, without the written approval of UL-CCIC COMPANY LIMITED. . Open View of EUT Internal View of EUT-1 FCC ID: 2ASWB-FS3 IC: 24918-FS3 Page 3 of 10 UL-CCIC COMPANY LIMITED This report shall not be reproduced except in full, without the written approval of UL-CCIC COMPANY LIMITED. . Internal View of EUT-2 Internal View of EUT-3 FCC ID: 2ASWB-FS3 IC: 24918-FS3 Page 4 of 10 UL-CCIC COMPANY LIMITED This report shall not be reproduced except in full, without the written approval of UL-CCIC COMPANY LIMITED. . Internal View of EUT-4 Internal View of EUT-5 FCC ID: 2ASWB-FS3 IC: 24918-FS3 Page 5 of 10 UL-CCIC COMPANY LIMITED This report shall not be reproduced except in full, without the written approval of UL-CCIC COMPANY LIMITED. . Internal View of EUT-6 Internal View of EUT-7 FCC ID: 2ASWB-FS3 IC: 24918-FS3 Page 6 of 10 UL-CCIC COMPANY LIMITED This report shall not be reproduced except in full, without the written approval of UL-CCIC COMPANY LIMITED. . Internal View of EUT-8 Internal View of EUT-9 FCC ID: 2ASWB-FS3 IC: 24918-FS3 Page 7 of 10 UL-CCIC COMPANY LIMITED This report shall not be reproduced except in full, without the written approval of UL-CCIC COMPANY LIMITED. . Internal View of EUT-10 Internal View of EUT-11 FCC ID: 2ASWB-FS3 IC: 24918-FS3 Page 8 of 10 UL-CCIC COMPANY LIMITED This report shall not be reproduced except in full, without the written approval of UL-CCIC COMPANY LIMITED. . Internal View of EUT-12 Internal View of EUT-13 FCC ID: 2ASWB-FS3 IC: 24918-FS3 Page 9 of 10 UL-CCIC COMPANY LIMITED This report shall not be reproduced except in full, without the written approval of UL-CCIC COMPANY LIMITED. . Internal View of EUT-14 Internal View of EUT-15 FCC ID: 2ASWB-FS3 IC: 24918-FS3 Page 10 of 10 UL-CCIC COMPANY LIMITED This report shall not be reproduced except in full, without the written approval of UL-CCIC COMPANY LIMITED. . RF Module location
The results reported herein have been performed in accordance with the laboratory’s terms of accreditation. This report shall not be reproduced except in full without the written approval of the Laboratory. The results in this report apply to the test sample(s) mentioned above at the time of the testing period only and are not to be used to indicate applicability to other similar products. This report does not imply that the product(s) has met the criteria for certification. RF EXPOSURE REPORT For Smart Cordless Hard Floor Cleaner MODEL NUMBER: FW05US0001 ADDITIONAL MODEL NUMBER: FW05CA0001, FW05US0201 PROJECT NUMBER: 4789256329 REPORT NUMBER: 4789256329-2 FCC ID: 2ASWB-FS3 IC: 24918-FS3 ISSUE DATE: Jan. 14, 2020 Prepared for Ecovacs Robotics Co Ltd Prepared by UL-CCIC COMPANY LIMITED No. 2, Chengwan Road, Suzhou Industrial Park, People’s Republic of China Tel: +86 769 22038881 Fax: +86 769 33244054 Website: www.ul.com REPORT No.: 4789259184-2 Page 2 of 6 UL-CCIC COMPANY LIMITED This report shall not be reproduced except in full, without the written approval of UL-CCIC COMPANY LIMITED.. TABLE OF CONTENTS 1. ATTESTATION OF TEST RESULTS ................................................................................. 3 2. TEST METHODOLOGY ..................................................................................................... 4 3. FACILITIES AND ACCREDITATION ................................................................................. 4 4. REQUIREMENT ................................................................................................................. 5 REPORT No.: 4789259184-2 Page 3 of 6 UL-CCIC COMPANY LIMITED This report shall not be reproduced except in full, without the written approval of UL-CCIC COMPANY LIMITED.. 1. ATTESTATION OF TEST RESULTS Applicant Information Company Name: Ecovacs Robotics Co Ltd Address: No. 108 Shihu Road West, Wuzhong Zone,Suzhou, 215168 P.R.China Manufacturer Information Company Name: Ecovacs Robotics Co Ltd Address: No. 108 Shihu Road West, Wuzhong Zone,Suzhou, 215168 P.R.China Factory Information Company Name: Ecovacs Robotics Co Ltd Address: No. 108 Shihu Road West, Wuzhong Zone,Suzhou, 215168 P.R.China EUT Description Product Name Smart Cordless Hard Floor Cleaner Model Name FW05US0001 Additional No. FW05CA0001, FW05US0201 Sample Number 2748831 Data of Receipt Sample Dec. 11, 2019 Date Tested Dec. 11, 2019~ Jan. 14, 2020 APPLICABLE STANDARDS STANDARD TEST RESULTS FCC Guidelines for Human Exposure IEEE C95.1 Complies Prepared By: Reviewed By: Tom Tang Chris Zhong Engineer Project Associate Senior Project Engineer Authorized By: Scholl Zhang Laboratory Leader REPORT No.: 4789259184-2 Page 4 of 6 UL-CCIC COMPANY LIMITED This report shall not be reproduced except in full, without the written approval of UL-CCIC COMPANY LIMITED.. 2. TEST METHODOLOGY The tests documented in this report were performed in accordance with KDB 447498 D01 General RF Exposure Guidance v06 and FCC Guidelines for Human Exposure IEEE C95.1. 3. FACILITIES AND ACCREDITATION Test Location UL-CCIC Company Limited, EMC&RF Lab Address No. 2, Chengwan Road, Suzhou Industrial Park, Suzhou 215122 ,China Accreditation Certificate CNAS (Certificate No.: L2065) The Laboratory has been assessed and proved to be in compliance with CNAS, The Certificate Registration Number is L2065. A2LA (Certificate No.: 4829.01) UL-CCIC COMPANY LIMITED has been assessed and proved to be in compliance with A2LA. FCC (FCC Designation No.: CN1247) UL-CCIC COMPANY LIMITED has been recognized to perform compliance testing on equipment subject to the Commission's Declaration of Conformity (DoC) and Certification rules. IC (IC Designation No.: 25056) UL-CCIC COMPANY LIMITED has been recognized to perform compliance testing on equipment subject to the Commission's Declaration of Conformity (DoC) and Certification rules. Note 1: All tests measurement facilities use to collect the measurement data are located at No. 2, Chengwan Road, Suzhou Industrial Park, Suzhou 215122, People’s Republic of China Note 2: For below 30MHz, lab had performed measurements at test anechoic chamber and comparing to measurements obtained on an open field site. These measurements below 30MHz had been correlated to measurements performed on an OFS. Note 3: The test anechoic chamber in UL-CCIC COMPANY LIMITED had been calibrated and compared to the open field sites and the test anechoic chamber is shown to be equivalent to or worst case from the open field site. REPORT No.: 4789259184-2 Page 5 of 6 UL-CCIC COMPANY LIMITED This report shall not be reproduced except in full, without the written approval of UL-CCIC COMPANY LIMITED.. 4. REQUIREMENT LIMIT Limits for General Population/Uncontrolled Exposure Limits for General Population/Uncontrolled Exposure Frequency Range (MHz) Electric Field Strength (E) (V/m) Magnetic Field Strength (H) (A/m) Power Density (S) (mW/cm 2 ) Averaging Time |E| 2 , |H| 2 or S (minutes) 0.3-1.34 614 1.63 (100)* 30 1.34-30 824/f 2.19/f (180/f2)* 30 30-300 27.5 0.073 0.2 30 300-1500 -- -- f/150 30 1500-100,000 -- -- 1.0 30 Note 1: f = frequency in MHz, * means Plane-wave equivalent power density Note 2: General population/uncontrolled exposures apply in situations in which the general public may be exposed, or in which persons that are exposed as a consequence of their employment may not be fully aware of the potential for exposure or cannot exercise control over their exposure. Note 3: The limit value 1.0mW/cm 2 is available for this EUT. MPE CALCULATION METHOD S =PG/(4πR 2 ) where: S = power density (in appropriate units, e.g. mW/ cm2) P = power input to the antenna (in appropriate units, e.g., mW) (the measured power value see to the tune-up document) G = power gain of the antenna in the direction of interest relative to an isotropic radiator R = distance to the center of radiation of the antenna (appropriate units, e.g., cm) REPORT No.: 4789259184-2 Page 6 of 6 UL-CCIC COMPANY LIMITED This…
Text truncated - open the document above for the full version.
The results reported herein have been performed in accordance with the laboratory’s terms of accreditation. This report shall not be reproduced except in full without the written approval of the Laboratory. The results in this report apply to the test sample(s) mentioned above at the time of the testing period only and are not to be used to indicate applicability to other similar products. This report does not imply that the product(s) has met the criteria for certification. FCC 47 CFR PART 15 SUBPART C ISED RSS 247 ISSUE 2 CERTIFICATION TEST REPORT For Smart Cordless Hard Floor Cleaner MODEL NUMBER: FW05US0001 ADDITIONAL MODEL NUMBER: FW05CA0001, FW05US0201 PROJECT NUMBER: 4789256329 REPORT NUMBER: 4789256329-1 FCC ID: 2ASWB-FS3 IC: 24918-FS3 ISSUE DATE: Jan. 14, 2020 Prepared for Ecovacs Robotics Co Ltd Prepared by UL-CCIC COMPANY LIMITED No. 2, Chengwan Road, Suzhou Industrial Park, People’s Republic of China Tel: +86 769 22038881 Fax: +86 769 33244054 Website: www.ul.com REPORT No.: 4789256329-1 ` Page 2 of 104 UL-CCIC COMPANY LIMITED This report shall not be reproduced except in full, without the written approval of UL-CCIC COMPANY LIMITED. Revision History Rev. Issue Date Revisions Revised By V0 01/14/2020 Initial Issue REPORT No.: 4789256329-1 ` Page 3 of 104 UL-CCIC COMPANY LIMITED This report shall not be reproduced except in full, without the written approval of UL-CCIC COMPANY LIMITED. TABLE OF CONTENTS 1. ATTESTATION OF TEST RESULTS ................................................................................. 4 2. TEST METHODOLOGY ..................................................................................................... 6 3. FACILITIES AND ACCREDITATION ................................................................................. 6 4. CALIBRATION AND UNCERTAINTY ................................................................................ 7 4.1. MEASURING INSTRUMENT CALIBRATION .............................................................. 7 4.2. MEASUREMENT UNCERTAINTY ............................................................................... 7 5. EQUIPMENT UNDER TEST ............................................................................................... 8 5.1. DESCRIPTION OF EUT .............................................................................................. 8 5.2. MAXIMUM OUTPUT POWER...................................................................................... 9 5.3. CHANNEL LIST ........................................................................................................... 9 5.4. TEST CHANNEL CONFIGURATION ..........................................................................10 5.5. THE WORSE CASE POWER SETTING PARAMETER ..............................................10 5.6. DESCRIPTION OF AVAILABLE ANTENNAS .............................................................11 5.7. THE WORSE CASE CONFIGURATIONS ..................................................................11 5.8. TEST ENVIRONMENT ...............................................................................................12 5.9. DESCRIPTION OF TEST SETUP ...............................................................................13 5.10. MEASURING INSTRUMENT AND SOFTWARE USED ..........................................14 6. MEASUREMENT METHODS ............................................................................................15 7. ANTENNA PORT TEST RESULTS ...................................................................................16 7.1. ON TIME AND DUTY CYCLE .....................................................................................16 7.2. 6 dB BANDWIDTH AND 99% BANDWIDTH ...............................................................19 7.3. PEAK CONDUCTED OUTPUT POWER .....................................................................26 7.4. POWER SPECTRAL DENSITY ..................................................................................28 7.5. CONDUCTED BANDEDGE AND SPURIOUS EMISSIONS ........................................35 7.6. RADIATED TEST RESULTS ......................................................................................60 7.6.1. LIMITS AND PROCEDURE .................................................................................60 7.6.2. TEST ENVIRONMENT ........................................................................................65 7.6.3. RESTRICTED BANDEDGE ..........................…
Text truncated - open the document above for the full version.
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.41 GHz - 2.46 GHz | 98.63 mW |

SMART VACUUM CLEANER
Equipment Class
DTS - Digital Transmission System
SMART VACUUM CLEANER
Equipment Class
DTS - Digital Transmission System
SMART VACUUM CLEANER
Equipment Class
DTS - Digital Transmission System