Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Any Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment . This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.
EXHIBIT B - EUT EXTERNAL PHOTOGRAPHS
EXHIBIT C - EUT INTERNAL PHOTOGRAPHS uncover battery Antenna chip
China Certification ICT Co., Ltd (Dongguan) Report No.: CR230101804-00 Page 29 of 29 5. RF EXPOSURE EVALUATION 5.1 Applicable Standard FCC ยง1.1307(b)(3)(i)(A) a single RF source is exempt RF device (from the requirement to show data demonstrating compliance to RF exposure limits, as previously mentioned) if the available maximum time-averaged power is no more than 1 mW, regardless of separation distance. 5.2 Procedure According to 447498 D04 Interim General RF Exposure Guidance v01, clause 2.1.2- 1-mW Test Exemption: Per ยง1.1307(b)(3)(i)(A), a single RF source is exempt RF device (from the requirement to show data demonstrating compliance to RF exposure limits, as previously mentioned) if the available maximum time-averaged power is no more than 1 mW, regardless of separation distance. This exemption applies to all operating configurations and exposure conditions, for the frequency range 100 kHz to 100 GHz, regardless of fixed, mobile, or portable device exposure conditions. This is a standalone exemption, and it cannot be applied in conjunction with any other test exemption. 5.3 Measurement Result Frequency (MHz) Maximum ERP Power 1-mW Test Exemption dBm mW 433.92 -30.93 0.0008 Compliant Note: 1. Chose the maximum power to do MPE analysis. 2. This device maximum E - Field level is 66.42 dBฮผV/m at 3m, so the EIRP power is -28.78dBm. 3. EIRP(dBm) = Field Strength of Fundamental(dBuV/m)-95.2 4. ERP = EIRP โ 2.15 dB Result: Compliant. RF Exposure is exemption. ===== END OF REPORT =====
TEST REPORT Applicant: ShenZhen S-HANDE Technology Co., Ltd. Address: 2 /F, Building 8, XinXinTian Industrial Park, Sha Jing Street, BaoAn District, ShenZhen, China FCC ID: 2AT5OSHD-S054 Product Name: Wireless remote sex toy Standard(s): 47 CFR Part 15, Subpart C(15.231) ANSI C63.10-2013 The above equipment has been tested and found compliance with the requirement of the relative standards by China Certification ICT Co., Ltd (Dongguan) Report Number: CR230101804-00 Date Of Issue: 2023/2/7 Reviewed By: Sun Zhong Title: Manager Test Laboratory: China Certification ICT Co., Ltd (Dongguan) No. 113, Pingkang Road, Dalang Town, Dongguan, Guangdong, China Tel: +86-769-82016888 China Certification ICT Co., Ltd (Dongguan) Report No.: CR230101804-00 Page 2 of 29 Test Facility The Test site used by China Certification ICT Co., Ltd (Dongguan) to collect test data is located on the No. 113, Pingkang Road, Dalang Town, Dongguan, Guangdong, China. The lab has been recognized as the FCC accredited lab under the KDB 974614 D01 and is listed in the FCC Public Access Link (PAL) database, FCC Registration No. : 442868, the FCC Designation No. : CN1314. The lab has been recognized by Innovation, Science and Economic Development Canada to test to Canadian radio equipment requirements, the CAB identifier: CN0123. Declarations China Certification ICT Co., Ltd (Dongguan) is not responsible for the authenticity of any test data provided by the applicant. Data included from the applicant that may affect test results are marked with a triangle symbol โโฒโ. Customer model name, addresses, names, trademarks etc. are not considered data. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested. This report cannot be reproduced except in full, without prior written approval of the Company. This report is valid only with a valid digital signature. The digital signature may be available only under the Adobe software above version 7.0. This report may contain data that are not covered by the accreditation scope and shall be marked with an asterisk โโ โ. China Certification ICT Co., Ltd (Dongguan) Report No.: CR230101804-00 Page 3 of 29 CONTENTS T EST FACILITY .......................................................................................................................................... 2 DECLARATIONS .......................................................................................................................................... 2 DOCUMENT REVISION HISTORY .......................................................................................... 5 1. GENERAL INFORMATION .................................................................................................... 6 1.1 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT) ....................................................... 6 1.2 DESCRIPTION OF TEST CONFIGURATION ........................................................................................... 7 1.2.2 Support Equipment List and Details .............................................................................................................. 7 1.2.3 Support Cable List and Details ...................................................................................................................... 7 1.2.4 Block Diagram of Test Setup ......................................................................................................................... 7 1.3 MEASUREMENT UNCERTAINTY .......................................................................................................... 8 2. SUMMARY OF TEST RESULTS ............................................................................................ 9 3. REQUIREMENTS AND TEST PROCEDURES .................................................................. 10 3.1 AC LINE CONDUCTED EMISSIONS .................................................................................................... 10 3.1.1 Applicable Standard ..................................................................................................................................... 10 3.1.2 EUT Setup.................................................................................................................................................... 11 3.1.3 EMI Test Receiver Setup ............................................................................................................................. 11 3.1.4 Test Procedure ............................................................................................................................................. 12 3.1.5 Corrected Amplitude & Margin Calculation ................................................................................................ 12 3.2 RADIATION SPURIOUS EMISSIONS .................................................................................................... 13 3.2.1 Applicable Standard ..................................................................................................................................... 13 3.2.2 EUT Setup.................................................................................................................................................... 14 3.2.3 EMI Test Receiver & Spectrum Analyzer Setup ......................................................................................... 14 3.2.4 Test Procedure ............................................................................................................................................. 14 3.2.5 Corrected Amplitude & Margin Calculation ................................................................................................ 15 3.3 20 DB EMISSION BANDWIDTH: .......................................................................................................... 16 3.3.1 Applicable Standard ..................................................................................................................................... 16 3.3.2 EUT Setupโฆ
Text truncated - open the document above for the full version.
EXHIBIT D - TEST SETUP PHOTOGRAPHS Radiated Emission Below 1GHz View Radiated Emission Above 1GHz View
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15.231 | 433.92 MHz - 433.92 MHz | - |

SEX TOY
Equipment Class
DTS - Digital Transmission System
Wireless remote sex toy
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter