FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. SHENZHEN CLOBOT INTELLIGENT TECHNOLOGY CO.,LTD./
  3. 2AT9W-MT200

2AT9W-MT200Receiver

SHENZHEN CLOBOT INTELLIGENT TECHNOLOGY CO.,LTD.
Receiver - FCC ID 2AT9W-MT200 - SHENZHEN CLOBOT INTELLIGENT TECHNOLOGY CO.,LTD.
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Nov 23, 2020
Application Purpose
Original Equipment
Date of Application
Nov 23, 2020
Equipment Note
Receiver
Frequency Range
2412.00000000 - 2462.00000000
Company
SHENZHEN CLOBOT INTELLIGENT TECHNOLOGY CO.,LTD.
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

MT-200

Cover Letter(s)

Rev11/20/07 SHENZHENCLOBOTINTELLIGENTTECHNOLOGYCO.,LTD. FederalCommunicationsCommission AuthorizationandEvaluationDivision ConfidentialityRequestregardingapplicationforcertificationofFCCID:( 2AT9W-MT200 ). PursuanttoSections0.457and0.459oftheCommission’sRules,weherebyrequestconfidential treatmentofinformationaccompanyingthisapplicationasoutlinedbelow: ExhibitTypeFileName BlockDiagram,Layout,SCH,BlockDiagram.pdf,Layout.pdf,SCH.pdf, Theabovematerialscontaintradesecretsandproprietaryinformationnotcustomarilyreleasedto thepublic.Thepublicdisclosureofthesematerialsmaybeharmfultotheapplicantandprovide unjustifiedbenefitstoitscompetitors. TheapplicantunderstandsthatpursuanttoSection0.457oftheRules,disclosureofthis applicationandallaccompanyingdocumentationwillnotbemadebeforethedateoftheGrant forthisapplication. PursuanttoDA04-1705June15,2004oftheCommission’spublicnotice,wealsorequest temporaryconfidential(Nov13,2020~Feb12.2021)90days,treatmentofinformation accompanyingthisapplicationasoutlinedbelow: ExhibitTypeFileName ---- Sincerely, Signature:Date:2020-11-23 Name:tonyLi Company:SHENZHENCLOBOTINTELLIGENTTECHNOLOGYCO.,LTD.

Cover Letter(s)

We: SHENZHENCLOBOTINTELLIGENTTECHNOLOGYCO.,LTD. ModelsDeclarationLetter Company:SHENZHENCLOBOTINTELLIGENTTECHNOLOGYCO.,LTD. Address: AreaA&B,7/F,Building1,SZZTIndustrialPark,No.3TongguanRoad,YutangStreet, GuangmingNewDistrict,Shenzhen,China ProductName:RoboticVacuumCleaner Trademark:/ ModelNumber(s):MT-200 SeriesModel :MT-210;MT-220;MT-230;MT-240;MT-250;MT-260;MT-270;MT-280; MT-290 Difference:Thedifferencebetweenproductmodelsonlydependsontheappearancecolorand themodelnamingisdifferent.Otherpowersupplymethods,safetystructureandkey componentsarethesame,whichdonotaffectthesafetyandelectromagneticcompatibility performance. Signature:Date:2020-11-23 Name:tonyLi Title:Salesmanager Company:SHENZHENCLOBOTINTELLIGENTTECHNOLOGYCO.,LTD.

Cover Letter(s)

M:\MasterDocuments\TEMPLATES\POA_Letter.doc SHENZHENCLOBOTINTELLIGENTTECHNOLOGYCO.,LTD. FederalCommunicationsCommission AuthorizationandEvaluationDivision 1435OaklandMillsRoad Columbia,MD21046 Date:2020-11-23 SUBJECT:FCCApplicationfor(FCCID:2AT9W-MT200) ToWhomItMayConcern: We,theundersigned,herebyauthorizeWeiXiongWangatKSIGN(Guangdong)Testing Co.,Ltd.onourbehalf,toapplytotheFederalCommunicationsCommissiononour equipment.AnyandallactscarriedoutbyKSIGN(Guangdong)TestingCo.,Ltd.onour behalfshallhavethesameeffectasactsofourown. ThisistoadvisethatweareinfullcompliancewiththeAnti-DrugAbuseAct.We,the applicant,arenotsubjecttoadenialoffederalbenefitspursuanttoSection5301ofthe Anti-DrugActof1988,21USC853a,andnopartytotheapplicationissubjecttoadenial offederalbenefitspursuanttothatsection. Regards, Signature: Name:tonyLi Company:SHENZHENCLOBOTINTELLIGENTTECHNOLOGYCO.,LTD.

External Photos

Page1of12 ExternalPhotographs OutlookofMT-210;MT-220;MT-230;MT-240 Page2of12 OutlookofMT-250;MT-260;MT-270;MT-280;MT-290 Page3of12 Page4of12 Page5of12 Page6of12 Page7of12 Page8of12 Page9of12 Page10of12 Page11of12 Page12of12

ID Label/Location Info

Label Location Size:35*33mm

Internal Photos

Page1of13 InternalPhotographs Page2of13 Page3of13 Page4of13 Page5of13 Page6of13 Page7of13 Page8of13 Page9of13 Page10of13 Page11of13 Page12of13 Page13of13 Antenna

RF Exposure Info

KSIGN(Guangdong)TestingCo.,Ltd. WestSideof1/F.,BuildingC,ZoneA,FuyuanNewFactory,JiujiuIndustrialPark, Minzhu,Shatou,Shajing,Bao'anDistrict,Shenzhen,Guangdong,People’sRepublicofChina Tel.:+(86)755-29852678Fax:+(86)755-29852397E-mail:[email protected]:www.gdksign.com KSIGN(Guangdong)TestingCo.,Ltd. MaximumPermissibleExposureEvaluation FCCID:2AT9W-MT200 AccordingtoFCC1.1310:Thecriterialistedinthefollowingtableshallbeusedtoevaluatethe environmentimpactofhumanexposuretoradiofrequency(RF)Radiationasspecifiedin§1.1307(b) EUTSpecification EUT RoboticVacuumCleaner Frequencyband(Operating) WLAN:2.412GHz~2.462GHz/2.422GHz~2.452GHz WCDMABandII,BandIV,BandV LTEFDDBand2,Band4,Band5,Band12 Others Devicecategory Portable(<20cmseparation) Mobile(>20cmseparation) Fixed(>20cmseparation) Others___ Exposureclassification Occupational/Controlledexposure(S=5mW/cm2) GeneralPopulation/Uncontrolledexposure(S=1mW/cm2) Antennadiversity Singleantenna Multipleantennas Txdiversity Rxdiversity Tx/Rxdiversity Max.outputpowerWIFI:13.60dBm Antennagain(Max)2.5dBi Evaluationapplied MPEEvaluation SAREvaluation Page2of2 KSIGN(Guangdong)TestingCo.,Ltd. LimitsforMaximumPermissibleExposure(MPE) Frequency Range(MHz) ElectricField Strength(V/m) MagneticField Strength(A/m) Power Density(mW/cm 2 ) Average Time (A)LimitsforOccupational/ControlExposures 300-1500----F/3006 1500-100000----56 (B)LimitsforGeneralPopulation/UncontrolExposures 300-1500----F/15006 1500-100000----130 Friistransmissionformula:Pd=(Pout*G)\(4*pi*R 2 ) Where Pd=PowerdensityinmW/cm 2 Pout=outputpowertoantennainmW G=gainofantennainlinearscale Pi=3.1416 R=distancebetweenobservationpointandcenteroftheradiatorincm PdthelimitofMPE1mW/cm 2 .Ifweknowthemaximumgainoftheantennaandtotalpowerinputto theantenna,throughthecalculation,wewillknowthedistancewheretheMPElimitisreached. MeasurementResult Operating Mode Channel Frequency (MHz) Max. Measured Power (dBm) Tuneup tolerance (dBm) Max. Tuneup Power (dBm) Antenna Gain (dBi) Power densityat 20cm (mW/cm 2 ) Power density Limits (mW/cm 2 ) 802.11b 243713.6013.60±114.602.50.01021 802.11g 243711.6411.64±112.642.50.00651 802.11n (HT20) 24379.519.51±110.512.50.00401 802.11n (HT40) 24228.438.43±19.432.50.00311 Note Foramoredetailedfeaturesdescription,pleaserefertotheRFTestReport. **********************THEEND**********************

Test Report

Page 2 of 95 Report No.:KS2009S01073E KSIGN(Guangdong) Testing Co., Ltd. TABLE OF CONTENTS Page 1. TEST SUMMARY .............................................................................................................................................................. 3 1.1. TEST STANDARDS ................................................................................................................................................................. 3 1.2. REPORT VERSION .................................................................................................................................................................. 3 1.3. TEST DESCRIPTION ............................................................................................................................................................... 4 1.4. TEST FACILITY ...................................................................................................................................................................... 5 1.5. MEASUREMENT UNCERTAINTY ................................................................................................................................................ 6 1.6. ENVIRONMENTAL CONDITIONS ................................................................................................................................................ 6 2. GENERAL INFORMATION ................................................................................................................................................. 7 2.1. CLIENT INFORMATION ........................................................................................................................................................... 7 2.2. GENERAL DESCRIPTION OF EUT .............................................................................................................................................. 7 2.3. OPERATION STATE ................................................................................................................................................................. 8 2.4. MEASUREMENT INSTRUMENTS LIST ......................................................................................................................................... 9 2.5. TEST SOFTWARE ................................................................................................................................................................. 10 3. TEST ITEM AND RESULTS ............................................................................................................................................... 11 3.1. ANTENNA REQUIREMENT ..................................................................................................................................................... 11 3.2. CONDUCTED EMISSION ....................................................................................................................................................... 12 3.3. BANDWIDTH ..................................................................................................................................................................... 15 3.4. PEAK OUTPUT POWER ........................................................................................................................................................ 34 3.5. POWER SPECTRAL DENSITY .................................................................................................................................................. 36 3.6. BAND EDGE AND SPURIOUS EMISSION (CONDUCTED) ................................................................................................................ 45 3.7. BAND EDGE EMISSIONS(RADIATED) ....................................................................................................................................... 53 3.8. SPURIOUS EMISSION (RADIATED) .......................................................................................................................................... 58 4. EUT TEST PHOTOS ......................................................................................................................................................... 69 5. PHOTOGRAPHS OF EUT CONSTRUCTIONAL ................................................................................................................... 71 Page 3 of 95 Report No.:KS2009S01073E KSIGN(Guangdong) Testing Co., Ltd. 1. TEST SUMMARY 1.1. Test Standards The tests were performed according to following standards: FCC Rules Part 15.247: Operation within the bands of 902-928MHz, 2400-2483.5MHz, and 5725-5850MHz. ANSI C63.10-2013: American National Standard for Testing Unlicensed Wireless Devices. 1.2. Report version Revised No. Date of issue Description 01 Sep. 29, 2020 Original Page 4 of 95 Report No.:KS2009S01073E KSIGN(Guangdong) Testing Co., Ltd. 1.3. Test Description FCC Part 15 Subpart C(15.247) Test Item Standard Section Result Test Engineer FCC Antenna Requirement 15.203 Pass Rory Huang Conducted Emission 15.207 Pass Rory Huang 6dB&99% Bandwidth 15.247(a)(2) Pass Rory Huang Peak Output Power 15.247(b) Pass Rory Huang Power Spectral Density 15.247(e) Pass Rory Huang Restricted Band 15.247(d)/15.205 Pass Rory Huang Band Edge and Spurious Emission(Conducted) 15.247(d) Pass Rory Huang Spurious Emission(Radiated) 15.247(d)&15.209 Pass Rory Huang Note: The measurement uncertainty is not included in the test result. Page 5 of 95 Report No.:KS2009S01073E KSIGN(Guangdong) Testing Co., Ltd. 1.4. Test Facility Address of the report laboratory KSIGN(Guangdong) Testing Co., Ltd. West Side of 1/F., Building C, Zone A, Fuyuan New Factory, Jiujiu Industrial Park, Minzhu,Shatou, Shajing, Bao'an District, Shenzhen, Guangdong, People’s Republic of China Laboratory accreditation The test facility is recognized, certified, or accredited by the following organizations: CNAS-Lab Code: L13261 KSIGN(Guangdong) Testing Co., Ltd. has been assessed and proved to be in Compliance wi…

Text truncated - open the document above for the full version.

Test Report

Page 51 of 95 Report No.: KS2009S01073 KSIGN(Guangdong) Testing Co., Ltd. CH11-SE 802.11n(HT40) CH03-Bandedge CH09-Bandedge CH03-SE Page 52 of 95 Report No.: KS2009S01073 KSIGN(Guangdong) Testing Co., Ltd. CH06-SE CH09-SE Page 53 of 95 Report No.: KS2009S01073 KSIGN(Guangdong) Testing Co., Ltd. 3.7. Band Edge Emissions(Radiated) Limit Restricted Frequency Band (MHz) (dBuV/m)(at 3m) Peak Average 2310 ~2390 74 54 2483.5 ~2500 74 54 Note: All restriction bands have been tested, only the worst case is reported. Test Configuration Test Procedure 1. The EUT was setup and tested according to ANSI C63.10:2013 requirements. 2. The EUT is placed on a turn table which is 1.5 meter above ground. The turn table is rotated 360 degrees to determine the position of the maximum emission level. 3. The EUT was positioned such that the distance from antenna to the EUT was 3 meters. 4. The antenna is scanned from 1 meter to 4 meters to find out the maximum emission level. This is repeated for both horizontal and vertical polarization of the antenna. In order to find the maximum emission, all of the interface cables were manipulated according to ANSI C63.10:2013 on radiated measurement. 5. The receiver set as follow: RBW=1MHz, VBW=3MHz PEAK detector for Peak value. RBW=1MHz, VBW=10Hz with Average detector for Average Value. Test Mode Please refer to the clause 2.3. Test Results Note: 1.Measurement = Reading level + Correct Factor Correct Factor=Antenna Factor + Cable Loss -Preamplifier Factor 2.Pre-scan 802.11b, 802.11g, 802.11n(HT20) and 802.11n(HT40) mode, and found the 802.11b mode which it is worse case, so only show the test data for worse case. Page 54 of 95 Report No.: KS2009S01073 KSIGN(Guangdong) Testing Co., Ltd. Test Voltage: DC 12.8V Ant. Pol. Horizontal Test Mode: TX 802.11b Mode 2412MHz Measurement = Reading level + Correct Factor Page 55 of 95 Report No.: KS2009S01073 KSIGN(Guangdong) Testing Co., Ltd. Test Voltage: DC 12.8V Ant. Pol. Vertical Test Mode: TX 802.11b Mode 2412 MHz Measurement = Reading level + Correct Factor Page 56 of 95 Report No.: KS2009S01073 KSIGN(Guangdong) Testing Co., Ltd. Test Voltage: DC 12.8V Ant. Pol. Horizontal Test Mode: TX 802.11b Mode 2462MHz Measurement = Reading level + Correct Factor Page 57 of 95 Report No.: KS2009S01073 KSIGN(Guangdong) Testing Co., Ltd. Test Voltage: DC 12.8V Ant. Pol. Vertical Test Mode: TX 802.11b Mode 2462MHz Measurement = Reading level + Correct Factor Page 58 of 95 Report No.: KS2009S01073 KSIGN(Guangdong) Testing Co., Ltd. 3.8. Spurious Emission (Radiated) Limit Radiated Emission Limits (9 kHz~1000 MHz) Frequency (MHz) Field Strength (microvolt/meter) Measurement Distance (meters) 0.009~0.490 2400/F(KHz) 300 0.490~1.705 24000/F(KHz) 30 1.705~30.0 30 30 30~88 100 3 88~216 150 3 216~960 200 3 Above 960 500 3 Radiated Emission Limit (Above 1000MHz) Frequency (MHz) Distance Meters(at 3m) Peak Average Above 1000 74 54 Note: (1) The tighter limit applies at the band edges. (2) Emission Level (dBuV/m)=20log Emission Level (uV/m). Test Configuration Below 30MHz Test Setup Page 59 of 95 Report No.: KS2009S01073 KSIGN(Guangdong) Testing Co., Ltd. Below 1000MHz Test Setup Above 1GHz Test Setup Test Procedure 1. The EUT was setup and tested according to ANSI C63.10:2013 2. The EUT is placed on a turn table which is 0.8 meter above ground for below 1 GHz, and 1.5 m for above 1 GHz. The turn table is rotated 360 degrees to determine the position of the maximum emission level. 3. The EUT was set 3 meters from the receiving antenna, which was mounted on the top of a variable height antenna tower. 4. For each suspected emission, the EUT was arranged to its worst case and then tune the Antenna tower (from 1 m to 4 m) and turntable (from 0 degree to 360 degrees) to find the maximum reading. A pre-amp and a high pass filter are used for the test in order to get better signal level to comply with the guidelines. 5. Set to the maximum power setting and enable the EUT transmit continuously. 6. Use the following spectrum analyzer settings (1) Span shall wide enough to fully capture the emission being measured; (2) Below 1 GHz: RBW=120 kHz, VBW=300 kHz, Sweep=auto, Detector function=peak, Trace=max hold; If the emission level of the EUT measured by the peak detector is 3 dB lower than the applicable limit, the peak emission level will be reported. Otherwise, the emission measurement will be repeated using the quasi-peak detector and reported. (3) From 1 GHz to 10 th harmonic: RBW=1MHz, VBW=1MHz Peak detector for Peak value. RBW=1MHz, VBW=10Hz RMS detector for Average value. Page 60 of 95 Report No.: KS2009S01073 KSIGN(Guangdong) Testing Co., Ltd. Test Mode Please refer to the clause 2.3. Test Result 9 KHz~30 MHz and 18GHz~25GHz From 9 KHz~30 MHz and 18GHz~25GHz: Conclusion: PASS Note: 1) Measurement = Reading level + Correct Factor Correct Factor=Antenna Factor + Cable Loss -Preamplifier Factor 2) The peak level is lower than average limit(54 dBuV/m), this data is the too weak instrument of signal is unable to test. 3) The emission levels of other frequencies are very lower than the limit and not show in test report. 4) The amplitude of spurious emissions which are attenuated by more than 20dB below the permissible value has no need to be reported. 5) Pre-scan 802.11b/g/n(HT20/HT40) modulation, and found the 802.11b modulation 2412MHz which it is worse case for 30MHz-1GHz , so only show the test data for worse case. 6) Pre-scan 802.11b/g/n(HT20/HT40) modulation, and found the 802.11b modulation which it is worse case for above 1GHz, so only show the test data for worse case. BELOW 30MHZ No emission found between lowest internal used/generated frequencies to 30MHz. Page 61 of 95 Report No.: KS2009S01073 KSIGN(Guangdong) Testing Co., Ltd. 30MHz-1GHz Test Voltage: DC 12.8V Ant. Pol. Horizontal Test Mode: TX 802.11b Mode 2412MHz Measurement = Reading Level+ Correct Factor Page 62 of 95 Report No.: KS2009S01073 KSIGN(Guangdong) Testing Co., Ltd. Test Voltage: DC 12…

Text truncated - open the document above for the full version.

Test Setup Photos

TESTPHOTOS RadiatedEmissions(30MHz~1000MHz) RadiatedEmissions(Above1GHz) RFConducted ConductedEmission

Contact Information

Applicant

tony Li(sales manager)
[email protected]+86 0755-33506266Fax: +86 0755-33506266

Test Firm

KSIGN (Guangdong) Testing Co., Ltd.Neil Wan
[email protected]86 0755 2985 2678

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.41 GHz - 2.46 GHz22.90 mW
Confidentiality
Long Term
Grant Notes
Output Power listed is the maximum conducted output power. This device must only be operated so as to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. This device supports 20 and 40 MHz bandwidth modes.

Other Applications from SHENZHEN CLOBOT INTELLIGENT TECHNOLOGY CO.,LTD.

Robotic Vacuum Cleaner - FCC ID 2AT9W-MT210 - SHENZHEN CLOBOT INTELLIGENT TECHNOLOGY CO.,LTD.
2AT9W-MT210

Robotic Vacuum Cleaner

Feb 17, 2023

Equipment Class

DTS - Digital Transmission System
Robotic Vacuum Cleaner - FCC ID 2AT9W-MT1000 - SHENZHEN CLOBOT INTELLIGENT TECHNOLOGY CO.,LTD.
2AT9W-MT1000

Robotic Vacuum Cleaner

Jun 05, 2021

Equipment Class

DTS - Digital Transmission System
Robotic Vacuum Cleaner - FCC ID 2AT9W-YS600 - SHENZHEN CLOBOT INTELLIGENT TECHNOLOGY CO.,LTD.
2AT9W-YS600

Robotic Vacuum Cleaner

Nov 17, 2020

Equipment Class

DTS - Digital Transmission System
Robotic Vacuum Cleaner - FCC ID 2AT9WMT-700668 - SHENZHEN CLOBOT INTELLIGENT TECHNOLOGY CO.,LTD.
2AT9WMT-700668

Robotic Vacuum Cleaner

Jun 14, 2020

Equipment Class

DTS - Digital Transmission System