Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
FCC ID:2AT9Z-RX4-1800
NanjingJuplinkIntelligentTechnologiesCo.,Ltd. Date:06/05/2020 To:FederalCommunicationsCommission, Authorization&EvaluationDivision, 7435OaklandMillsRoad, Columbia,MD21046 Re:RequestofConfidentialityforFCCID:2AT9Z-RX4-1800 ToWhomitmayconcern: Pursuanttosections0.457and0.459ofCommission’sRules(CFR47), andSection552(b)(4)oftheFreedomofInformationAct,NanjingJuplink IntelligentTechnologiesCo.,Ltd.herebyrequestsconfidentialityandtreatment ofcertaininformationaccompanyingthisapplication.Thematerialscontaintrade secretsandproprietaryinformationnotcustomarilyreleasedtothepublic.The publicdisclosureofthesemattersmightbeharmfultotheApplicantandprovide unjustifiedbenefitstoitscompetitors. WearealsoherebyrequestShort-TermConfidentialitytilldate11/25/2020(max time180daysfromgrantdate)asoutlinedinPublicNoticeDA04-1705.This provisionwillgiveNanjingJuplinkIntelligentTechnologiesCo.,Ltd.temporary confidentialityofcommerciallysensitiveinformationpriortoproductrelease. TherequestedPermanentandShort-TermConfidentialexhibitsarelistedas follows: PERMANENTANDSHORT-TERMCONFIDENTIALLIST ExhibitDescription PERMANENT 1BlockDiagram 2OperationalDescription 3Schematics 4BOM SHORT-TERM 5ExternalPhotos 6InternalPhotos 7Test-SetupPhotos 8UserManual TheApplicantunderstandsthatpursuanttoRule0.457,disclosureofthis applicationandallaccompanyingdocumentations,whereapplicable,willnotbe madepublicbeforethedateoftheGrantforthisapplication. Signatory Name : JamesXiong Companyname:NanjingJuplinkIntelligentTechnologiesCo.,Ltd. Address:No.757,DixiuRoad,BinjiangEconomicDevelopmentZone,Jiangning District,Nanjing , China Tel : +8613823169517 Email:[email protected]
NanjingJuplinkIntelligentTechnologiesCo.,Ltd. Ad-HocCountryCodeCoverLetter We,<NanjingJuplinkIntelligentTechnologiesCo.,Ltd.>,declarethatthisEUT(FCCID: 2AT9Z-RX4-1800)doesn’thaveAdHocModefunctionon“non-USfrequencies”.In addition,thefrequencyselectionfeatureisdisablebyfirmwarefordevicemarketed totheUS.ForDTSpartofthisdevice,onlychannel1~11willbeusedinNorth America.Countrycodeselectionisdisabled. Shouldyouhaveanyquestionsorcommentsregardingthismatter,pleasehavemy bestattention. Sincerelyyours, ___________________ JamesXiong Companyname:NanjingJuplinkIntelligentTechnologiesCo.,Ltd. Tel:+8613823169517 Fax:025-83677687 Email:[email protected]
NanjingJuplinkIntelligentTechnologiesCo.,Ltd. Date:06/05/2020 To:FederalCommunicationsCommission, Authorization&EvaluationDivision, 7435OaklandMillsRoad, Columbia,MD21046 ToWhomItMayConcern: TheNanjingJuplinkIntelligentTechnologiesCo.,Ltd.,theundersigned,hereby authorizesMr.QijieXiaofromKehu-MorlabTestLaboratorytoactonthe behalfoftheNanjingJuplinkIntelligentTechnologiesCo.,Ltd.solelyinmatters relatingtotheapplicationforanFCCequipmentauthorizationforFCCID: 2AT9Z-RX4-1800includingthesigningofdocumentsinconnectionwiththis Application.NecessaryactscarriedoutKehu-MorlabTestLaboratoryonour behalfoftheNanjingJuplinkIntelligentTechnologiesCo.,Ltd.inconnectionwith theApplicationshallhavethesameeffectasactsoftheNanjingJuplinkIntelligent TechnologiesCo.,Ltd..NanjingJuplinkIntelligentTechnologiesCo.,Ltd.also herebycertifythatnopartytothisapplicationissubjecttoadenialofbenefits, includingFCCbenefits,pursuanttoSection5301oftheAnti-DrugAbuseActof 1988,21U.S.C.862. Thankyouforyourattentiontothismatter. YoursSincerely, Signatory: Contactname:JamesXiong Title:Generalmanager Tel:+8613823169517 Email:[email protected] Companyname:NanjingJuplinkIntelligentTechnologiesCo.,Ltd.
NanjingJuplinkIntelligentTechnologiesCo.,Ltd. UNIIDeclarationLetter WehavedeclaredbelowfeaturedforFCCequipmentauthorization,deviceFCCID:2AT9Z-RX4-1800 (1)DFSDevice--Master,ClientwithRadardetectioncapability, Clientwithoutradardetectioncapability,N/A (2)Active/PassiveScanning,adhocmodeaccesspointcapability FrequencyBand (MHz) ActiveScanning (thedevicecan transmitaprobe (beacon)) passivescanning (wherethedevice is canlistenonly withno probes) AdHocMode capability Accesspoint capability 2412–2462MHzYes,NoYes,NoYes,NoYes,No 2422–2452MHzYes,NoYes,NoYes,NoYes,No 5745–5825MHzYes,NoYes,NoYes,NoYes,No 5755–5795MHzYes,NoYes,NoYes,NoYes,No 5180–5240MHzYes,NoYes,NoYes,NoYes,No 5190–5230MHzYes,NoYes,NoYes,NoYes,No 5260–5320MHzYes,NoYes,NoYes,NoYes,No 5270–5310MHzYes,NoYes,NoYes,NoYes,No 5500–5700MHzYes,NoYes,NoYes,NoYes,No 5510–5670MHzYes,NoYes,NoYes,NoYes,No (3)Countrycodeselectionability-Yes,No Ifno,plsexplainhowwasimplemented:useMicrosoftnetworkutility (4)Meet15.202requirement-Yes,No, plscheckbelow: Amasterdeviceisdefinedasadeviceoperatinginamodeinwhichithasthecapabilityto transmitwithoutreceivinganenablingsignal.Inthismodeitisabletoselectachannelandinitiatea networkbysendingenablingsignalstootherdevices Aclientdeviceisdefinedasadeviceoperatinginamodeinwhichthetransmissionsofthedevice areundercontrolofthemaster.Adeviceinclientmodeisnotabletoinitiateanetwork. (5)Forclientdevicesthathavesoftwareconfigurationcontroltooperateindifferentmodes(active scanninginsomeandpassivescanninginothers)indifferentbands(deviceswithmultipleequipment classesorthosethatoperateonnon-DFSfrequencies)ormodulardeviceswhichconfigurethemodes ofoperationsthroughsoftware,theapplicationmustprovidesoftwareandoperationsdescriptionon howthesoftwareand/orhardwareisimplementedtoensurethatproperoperationsmodescannot bemodifiedbyenduseroraninstaller. Apply,NoApply, (Ifapply,plshelptoprovideexplanationonhowitwasimplement(Byhardwareorsoftware,andhowsoftwarewascontrolled) Ifyouhaveanyquestions,pleasefeelfreetocontactmeattheaddressshownbelow. Yourssincerely, Signatory PrintedName Position
Kehu-Morlab TestLaboratory XIAMENMORLABCOMMUNICATIONSTECHNOLOGYCo.,Ltd. Unit101,No.1732GangzhongRoad,XiamenArea,PilotFreeTradeZone(Fujian),P.R.China Tel:+865925612050 Fax:+865925612095 Page 1 of 3 FCCID:2AT9Z-RX4-1800 ExternalPhotos Allsampleview EUTunittopview Kehu-Morlab TestLaboratory XIAMENMORLABCOMMUNICATIONSTECHNOLOGYCo.,Ltd. Unit101,No.1732GangzhongRoad,XiamenArea,PilotFreeTradeZone(Fujian),P.R.China Tel:+865925612050 Fax:+865925612095 Page 2 of 3 EUTunitbottomview EUTunitfrontview Kehu-Morlab TestLaboratory XIAMENMORLABCOMMUNICATIONSTECHNOLOGYCo.,Ltd. Unit101,No.1732GangzhongRoad,XiamenArea,PilotFreeTradeZone(Fujian),P.R.China Tel:+865925612050 Fax:+865925612095 Page 3 of 3 EUTunitbackview EUTunitsideview
FCC ID:2AT9Z-RX4-1800 Label location:
Kehu-Morlab TestLaboratory XIAMENMORLABCOMMUNICATIONSTECHNOLOGYCo.,Ltd. Unit101,No.1732GangzhongRoad,XiamenArea,PilotFreeTradeZone(Fujian),P.R.China Tel:+865925612050 Fax:+865925612095 Page1of4 FCCID:2AT9Z-RX4-1800 InternalPhotos 1.uncoverview Kehu-Morlab TestLaboratory XIAMENMORLABCOMMUNICATIONSTECHNOLOGYCo.,Ltd. Unit101,No.1732GangzhongRoad,XiamenArea,PilotFreeTradeZone(Fujian),P.R.China Tel:+865925612050 Fax:+865925612095 Page2of4 Kehu-Morlab TestLaboratory XIAMENMORLABCOMMUNICATIONSTECHNOLOGYCo.,Ltd. Unit101,No.1732GangzhongRoad,XiamenArea,PilotFreeTradeZone(Fujian),P.R.China Tel:+865925612050 Fax:+865925612095 Page3of4 Kehu-Morlab TestLaboratory XIAMENMORLABCOMMUNICATIONSTECHNOLOGYCo.,Ltd. Unit101,No.1732GangzhongRoad,XiamenArea,PilotFreeTradeZone(Fujian),P.R.China Tel:+865925612050 Fax:+865925612095 Page4of4 7.Antennaview ExternalAntenna0_5G ExternalAntenna1_5G ExternalAntenna1_2.4G ExternalAntenna0_2.4G
NOTE: 1.The report is invalid when there is no the approver signature and the special stamp for test report. 2.The test report shall not be reproduced except in full without prior written permission of the company. 3.The report copy is invalid when there is no the special stamp for test repor. 4.The altered report is invalid. 5.The entrust test is responsibility for the received sample only. Kehu-Morlab Test Laboratory XIAMEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd. Unit 101, No.1732 Gangzhong Road, Xiamen Area, Pilot Free Trade Zone (Fujian) , P. R. China Tel: +86 592 5612050 Fax: +86 592 5612095 REPORT No.:XM19110014W04 RF EXPOSURE EVALUATION REPORT APPLICANT : Nanjing Juplink Intelligent Technologies Co., Ltd.. PRODUCT NAME : Dual-band Gigabit Router MODEL NAME : RX4-1800 BRAND NAME : JupLink FCC ID : 2AT9Z-RX4-1800 STANDARD(S) : 47 CFR§2.1091; KDB 447498 D01v06 RECEIPT DATE : 2020-01-03 TEST DATE : 2020-02-18 to 2020-02-21 ISSUE DATE : 2020-06-02 Edited by : Stefan Sun(Test engineer) Review by: Peng fuwei (Auditor) Approved by: Anne Liu ( Supervisor ) Kehu-Morlab Test Laboratory XIAMEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd. Unit 101, No.1732 Gangzhong Road, Xiamen Area, Pilot Free Trade Zone (Fujian) , P. R. China Tel: +86 592 5612050 Fax: +86 592 5612095 Page2 0f 6 REPORT No.:XM19110014W04 DIRECTORY 1. Technical Information ········································································································ 3 1.1. Applicant and Manufacturer Information ····································································· 3 1.2. Equipment Under Test (EUT) Description ··································································· 3 1.3. Applied Reference Documents ····················································································· 3 2. Device category and RF exposure limit ·········································································· 4 3. RF Exposure Evaluation ··································································································· 5 Annex A General Information ································································································· 6 Change History Issue Date Reason for change 1.0 2020-06-02 First edition Kehu-Morlab Test Laboratory XIAMEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd. Unit 101, No.1732 Gangzhong Road, Xiamen Area, Pilot Free Trade Zone (Fujian) , P. R. China Tel: +86 592 5612050 Fax: +86 592 5612095 Page3 0f 6 REPORT No.:XM19110014W04 1. Technical Information Note: Provide by manufacturer. 1.1. Applicant and Manufacturer Information Applicant: Nanjing Juplink Intelligent Technologies Co., Ltd. Applicant Address: No. 757, Dixiu Road, Binjiang Economic Development Zone, Jiangning District, Nanjing China Manufacturer: Sichuan Tianyi Comheart Telecom Co., Ltd. Manufacturer Address: No. 198, Section 1, Xueshan Avenue, Dayi County, Chengdu, Sichuan, China 1.2. Equipment Under Test (EUT) Description Product Name: Dual-band Gigabit Router Hardware Version: V1.0.0 Software Version: V1.0.1 Modulation Mode: 802.11b/g/n 802.11ac(HT20), 802.11ac(HT40),802.11ac(HT80) 802.11a,802.11n(HT20), 802.11n(HT40) 802.11ax(HEW20), 802.11ax(HEW40),802.11ax(HEW80) Operating Frequency Range: 802.11b/g/n-20MHz: 2.412GHz - 2.462GHz 802.11n-40MHz: 2.422GHz - 2.452GHz 5.180 GHz- 5.240 GHz;5.725GHz- 5.850GHz Modulation Type: DSSS, OFDM Antenna type: Dipole Antenna Antenna Gain: Ant 5 dBi 1.3. Applied Reference Documents Leading reference documents for testing: No. Identity Document Title 1 47 CFR§2.1091 Radiofrequency Radiation Exposure Evaluation: mobile devices 2 KDB 447498 D01v06 General RF Exposure Guidance Kehu-Morlab Test Laboratory XIAMEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd. Unit 101, No.1732 Gangzhong Road, Xiamen Area, Pilot Free Trade Zone (Fujian) , P. R. China Tel: +86 592 5612050 Fax: +86 592 5612095 Page4 0f 6 REPORT No.:XM19110014W04 2. Device category and RF exposure limit Per user manual, Based on 47CFR 2.1091, this device belongs to mobile device category with General Population/Uncontrolled exposure. Mobile Devices: 47CFR 2.1091(b) For purposes of this section, a mobile device is defined as a transmitting device designed to be used in other than fixed locations and to generally be used in such a way that a separation distance of at least 20 centimeters is normally maintained between the transmitter's radiating structure(s) and the body of the user or nearby persons. In this context, the term “fixed location” means that the device is physically secured at one location and is not able to be easily moved to another location. Transmitting devices designed to be used by consumers or workers that can be easily re-located, such as wireless devices associated with a personal computer, are considered to be mobile devices if they meet the 20 centimeter separation requirement. GENERAL POPULATION / UNCONTROLLED EXPOSURE The general population/uncontrolled exposure limits are applicable to situations in which the general public may be exposed or in which persons who are exposed as a consequence of their employment may not be made fully aware of the potential for exposure or cannot exercise control over their exposure. Members of the general public would come under this category when exposure is not employment-related; for example, in the case of a wireless transmitter that exposes persons in its vicinity. Warning labels placed on low-power consumer devices such as cellular telephones are not considered sufficient to allow the device to be considered under the occupational/controlled category, and the general population/uncontrolled exposure limits apply to these devices. TABLE 1—LIMITS FOR MAXIMUM PERMISSIBLE EXPOSURE (MPE) Frequency range (MHz) Electric field strength (V/m) Magnetic field strength (A/m) Power density (mW/cm 2 ) Averaging time (minutes) (B) Limits for General Population/Uncontrolled Exposure 0.3-1.34 614 1.63 *(100) 30 1.34-30 824/f 2.19/f *(180/f 2 ) 30 30-300…
Text truncated - open the document above for the full version.
NOTE:1.The report is invalid when there is no the approver signature and the special stamp for test report. 2.The test report shall not be reproduced except in full without prior written permission of the company. 3.The report copy is invalid when there is no the special stamp for test repor. 4.The altered report is invalid. 5.The entrust test is responsibility for the received sample only. Kehu-Morlab Test Laboratory XIAMEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd. Unit 101, No.1732 Gangzhong Road, Xiamen Area, Pilot Free Trade Zone (Fujian) , P. R. China Tel: +86 592 5612050 Fax: +86 592 5612095 Page10f149 REPORT No.:XM19110014W01 TEST REPORT APPLICANT :Nanjing Juplink Intelligent Technologies Co., Ltd. PRODUCT NAME:Dual-band Gigabit Router MODEL NAME:RX4-1800 BRAND NAME:JupLink FCC ID:2AT9Z-RX4-1800 STANDARD(S):47 CFR Part 15 Subpart C RECEIPT DATE:2020-01-07 TEST DATE:2020-02-18 to 2020-05-26 ISSUE DATE:2020-06-15 Edited by : Bowers Zeng(Test engineer) Review by: Elvis Wang(Auditor) Approved by: Anne Liu ( Supervisor ) Kehu-Morlab Test Laboratory XIAMEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd. Unit 101, No.1732 Gangzhong Road, Xiamen Area, Pilot Free Trade Zone (Fujian) , P. R. China Tel: +86 592 5612050 Fax: +86 592 5612095 Page20f149 REPORT No.:XM19110014W01 DIRECTORY 1. Technical Information...............................................................................................................3 1.1. Applicant and Manufacturer Information.........................................................................3 1.2. Equipment Under Test (EUT) Description.......................................................................3 1.3. Modulation Type and Data Rate of EUT...........................................................................4 1.4. Test Standards and Results ................................................................................................ 5 1.5. Environmental Conditions ................................................................................................... 5 2. 47 CFR Part 15C Requirements ............................................................................................. 6 2.1. Antenna requirement ............................................................................................................. 6 2.2. Output Power ........................................................................................................................... 7 2.3. Bandwidth..............................................................................................................................11 2.4. Conducted Spurious Emissions and Band Edge........................................................20 2.5. Power spectral density (PSD)...........................................................................................31 2.6. Restricted Frequency Bands............................................................................................47 2.7. Conducted Emission...........................................................................................................65 2.8. Radiated Emission...............................................................................................................69 Annex A Test Uncertainty........................................................................................................146 Annex B Testing Laboratory Information ............................................................................ 147 Change History VersionDateReason for change 1.02020-06-15First edition Kehu-Morlab Test Laboratory XIAMEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd. Unit 101, No.1732 Gangzhong Road, Xiamen Area, Pilot Free Trade Zone (Fujian) , P. R. China Tel: +86 592 5612050 Fax: +86 592 5612095 Page30f149 REPORT No.:XM19110014W01 1.Technical Information Note:Provide by applicant. 1.1. Applicant and Manufacturer Information Applicant:Nanjing Juplink Intelligent Technologies Co., Ltd. Applicant Address:No. 757, Dixiu Road, Binjiang Economic Development Zone, Jiangning District, Nanjing China Manufacturer:Sichuan Tianyi Comheart Telecom Co., Ltd. Manufacturer Address:No. 198, Section 1, Xueshan Avenue, Dayi County, Chengdu, Sichuan, China 1.2.Equipment Under Test (EUT) Description Product Name:Dual-band Gigabit Router Serial No:(N/A, marked #1 by test site) Hardware Version:V1.0.0 Software Version:V1.0.1 Modulation Type: DSSS, OFDM Operating Frequency Range: 802.11b/g/n-20MHz: 2.412GHz - 2.462GHz 802.11n-40MHz: 2.422GHz - 2.452GHz Channel Number: 802.11b/g/n-20MHz: 11 802.11n-40MHz: 7 Antenna Type: Dipole Antenna Antenna Gain: Ant 5 dBi Note 1:The EUT is operating at 2.4GHz ISM; it supports 802.11b, 802.11g, 802.11n and they are all tested in this report. For 802.11b/g/n-20MHz (2.4GHz band), the frequencies allocated is F (MHz) =2412+5*(n-1) (1<=n<=11). The lowest, middle, highest channel numbers of the EUT used and tested in this report are separately 1 (2412MHz), 6 (2437MHz) and 11 (2462MHz). For 802.11n-40MHz, the frequencies allocated is F (MHz) =2412+5*(n-1) (3<=n<=9). The lowest, middle, highest channel numbers of the EUT used and tested in this report are separately 3 (2422MHz), 6 (2437MHz) and 9 (2452MHz). Note 2:During test, the duty cycle of the EUT was setting to 100%. Note 3:The EUT has two antennas and supports a MIMO function. Kehu-Morlab Test Laboratory XIAMEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd. Unit 101, No.1732 Gangzhong Road, Xiamen Area, Pilot Free Trade Zone (Fujian) , P. R. China Tel: +86 592 5612050 Fax: +86 592 5612095 Page40f149 REPORT No.:XM19110014W01 Modulation Mode:TX Function 802.11b1TX 802.11g1TX 802.11n202TX 802.11n402TX Note 4:The EUT connected to the serial port of the computer with a serial communication cable, we use the dedicated software to control the EUT continuous transmission. Note 5:For conducted test item Maximum conducted output Power and Peak Power spectral density of each modulation mode, we recorded the test result of two antennas separ…
Text truncated - open the document above for the full version.
Kehu-Morlab Test Laboratory XIAMEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd. Unit 101, No.1732 Gangzhong Road, Xiamen Area, Pilot Free Trade Zone (Fujian) , P. R. China Tel: +86 592 5612050 Fax: +86 592 5612095 Page330f149 REPORT No.:XM19110014W01 (Channel = 6, 802.11b;ANT0) (Channel = 11, 802.11b;ANT0) Kehu-Morlab Test Laboratory XIAMEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd. Unit 101, No.1732 Gangzhong Road, Xiamen Area, Pilot Free Trade Zone (Fujian) , P. R. China Tel: +86 592 5612050 Fax: +86 592 5612095 Page340f149 REPORT No.:XM19110014W01 (Channel = 1, 802.11b;ANT1) (Channel = 6, 802.11b;ANT1) Kehu-Morlab Test Laboratory XIAMEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd. Unit 101, No.1732 Gangzhong Road, Xiamen Area, Pilot Free Trade Zone (Fujian) , P. R. China Tel: +86 592 5612050 Fax: +86 592 5612095 Page350f149 REPORT No.:XM19110014W01 (Channel = 11, 802.11b;ANT1) 802.11g Test mode A. Test Verdict: ANT 0 Spectral power density (dBm/3kHz) Channel Frequency (MHz) Measured PSD (dBm/3kHz) Limit (dBm/3kHz) Verdict 12412-13.238PASS 62437-13.398PASS 112462-13.458PASS ANT 1 Spectral power density (dBm/3kHz) Channel Frequency (MHz) Measured PSD (dBm/3kHz) Limit (dBm/3kHz) Verdict 12412-13.518PASS 62437-13.408PASS 112462-13.508PASS Kehu-Morlab Test Laboratory XIAMEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd. Unit 101, No.1732 Gangzhong Road, Xiamen Area, Pilot Free Trade Zone (Fujian) , P. R. China Tel: +86 592 5612050 Fax: +86 592 5612095 Page360f149 REPORT No.:XM19110014W01 B. Test Plots: (Channel = 1, 802.11g;ANT0) (Channel = 6, 802.11g;ANT0) Kehu-Morlab Test Laboratory XIAMEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd. Unit 101, No.1732 Gangzhong Road, Xiamen Area, Pilot Free Trade Zone (Fujian) , P. R. China Tel: +86 592 5612050 Fax: +86 592 5612095 Page370f149 REPORT No.:XM19110014W01 (Channel = 11, 802.11g;ANT0) (Channel = 1, 802.11g;ANT1) Kehu-Morlab Test Laboratory XIAMEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd. Unit 101, No.1732 Gangzhong Road, Xiamen Area, Pilot Free Trade Zone (Fujian) , P. R. China Tel: +86 592 5612050 Fax: +86 592 5612095 Page380f149 REPORT No.:XM19110014W01 (Channel = 6, 802.11g;ANT1) (Channel = 11, 802.11g;ANT1) Kehu-Morlab Test Laboratory XIAMEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd. Unit 101, No.1732 Gangzhong Road, Xiamen Area, Pilot Free Trade Zone (Fujian) , P. R. China Tel: +86 592 5612050 Fax: +86 592 5612095 Page390f149 REPORT No.:XM19110014W01 802.11n-20MHz Test mode A. Test Verdict: Spectral power density (dBm/3kHz) Channel Frequency (MHz) Measured PSD (dBm/3kHz) Limit (dBm/3kHz) Verdict ANT 0ANT 1 Total 12412-12.65-12.33-9.478PASS 62437-12.96-13.11-9.058PASS 112462-12.76-12.19-9.458PASS B. Test Plots: (Channel = 1, 802.11n-20MHz;ANT0) Kehu-Morlab Test Laboratory XIAMEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd. Unit 101, No.1732 Gangzhong Road, Xiamen Area, Pilot Free Trade Zone (Fujian) , P. R. China Tel: +86 592 5612050 Fax: +86 592 5612095 Page400f149 REPORT No.:XM19110014W01 (Channel = 6, 802.11n-20MHz;ANT0) (Channel = 11, 802.11n-20MHz;ANT0) Kehu-Morlab Test Laboratory XIAMEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd. Unit 101, No.1732 Gangzhong Road, Xiamen Area, Pilot Free Trade Zone (Fujian) , P. R. China Tel: +86 592 5612050 Fax: +86 592 5612095 Page410f149 REPORT No.:XM19110014W01 (Channel = 1, 802.11n-20MHz;ANT1) (Channel = 6, 802.11n-20MHz;ANT1) Kehu-Morlab Test Laboratory XIAMEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd. Unit 101, No.1732 Gangzhong Road, Xiamen Area, Pilot Free Trade Zone (Fujian) , P. R. China Tel: +86 592 5612050 Fax: +86 592 5612095 Page420f149 REPORT No.:XM19110014W01 (Channel = 11, 802.11n-20MHz;ANT1) Kehu-Morlab Test Laboratory XIAMEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd. Unit 101, No.1732 Gangzhong Road, Xiamen Area, Pilot Free Trade Zone (Fujian) , P. R. China Tel: +86 592 5612050 Fax: +86 592 5612095 Page430f149 REPORT No.:XM19110014W01 802.11n-40MHz Test mode A. Test Verdict: Spectral power density (dBm/3kHz) Channel Frequency (MHz) Measured PSD (dBm/3kHz) Limit (dBm/3kHz) Verdict ANT 0ANT 1 Total 32422-16.17-15.08-12.588PASS 62437-15.60-15.38-12.488PASS 92452-16.24-15.44-12.818PASS B. Test Plots: (Channel = 3, 802.11n-40MHz;ANT0) Kehu-Morlab Test Laboratory XIAMEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd. Unit 101, No.1732 Gangzhong Road, Xiamen Area, Pilot Free Trade Zone (Fujian) , P. R. China Tel: +86 592 5612050 Fax: +86 592 5612095 Page440f149 REPORT No.:XM19110014W01 (Channel = 6, 802.11n-40MHz;ANT0) (Channel = 9, 802.11n-40MHz;ANT0) Kehu-Morlab Test Laboratory XIAMEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd. Unit 101, No.1732 Gangzhong Road, Xiamen Area, Pilot Free Trade Zone (Fujian) , P. R. China Tel: +86 592 5612050 Fax: +86 592 5612095 Page450f149 REPORT No.:XM19110014W01 (Channel = 3, 802.11n-40MHz;ANT1) (Channel = 6, 802.11n-40MHz;ANT1) Kehu-Morlab Test Laboratory XIAMEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd. Unit 101, No.1732 Gangzhong Road, Xiamen Area, Pilot Free Trade Zone (Fujian) , P. R. China Tel: +86 592 5612050 Fax: +86 592 5612095 Page460f149 REPORT No.:XM19110014W01 (Channel = 9, 802.11n-40MHz;ANT1) Kehu-Morlab Test Laboratory XIAMEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd. Unit 101, No.1732 Gangzhong Road, Xiamen Area, Pilot Free Trade Zone (Fujian) , P. R. China Tel: +86 592 5612050 Fax: +86 592 5612095 Page470f149 REPORT No.:XM19110014W01 2.6.Restricted Frequency Bands 2.6.1. Requirement According to FCC section 15.247(d), in any 100kHz bandwidth outside the frequency band in which the spread spectrum or digitally modulated intentional radiator is operating, the radio frequency power that is produced by the intentional radiator shall be at least 20dB below that in the 100kHz bandwidth within the band that contains the highest level of the desired power, In addition, radiated emissions which fall in the restricted bands, as defined in 15.205(a), must also comply with the radiated emission limits specified in 15.209(a). 2.6.2. Test Description A. Test Setup Th…
Text truncated - open the document above for the full version.
Kehu-Morlab TestLaboratory XIAMENMORLABCOMMUNICATIONSTECHNOLOGYCo.,Ltd. Unit101,No.1732GangzhongRoad,XiamenArea,PilotFreeTradeZone(Fujian),P.R.China Tel:+865925612050 Fax:+865925612095 Page1of3 Test-SetupPhotos 1.RadiatedTestPhoto 30MHz-1GHz Above1GHz FCCID:2AT9Z-RX4-1800 Kehu-Morlab TestLaboratory XIAMENMORLABCOMMUNICATIONSTECHNOLOGYCo.,Ltd. Unit101,No.1732GangzhongRoad,XiamenArea,PilotFreeTradeZone(Fujian),P.R.China Tel:+865925612050 Fax:+865925612095 Page2of3 2.ConductedEmission Kehu-Morlab TestLaboratory XIAMENMORLABCOMMUNICATIONSTECHNOLOGYCo.,Ltd. Unit101,No.1732GangzhongRoad,XiamenArea,PilotFreeTradeZone(Fujian),P.R.China Tel:+865925612050 Fax:+865925612095 Page3of3 3.RFconductedmeasured
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.41 GHz - 2.46 GHz | 113.00 mW |

Dual-band Gigabit Wi-Fi extender
Equipment Class
NII - Unlicensed National Information Infrastructure TX