FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. D.P.I.(H.K.) Limited/
  3. 2ATD3-IAMW20B

2ATD3-IAMW20BWireless Mouse

D.P.I.(H.K.) Limited
Wireless Mouse - FCC ID 2ATD3-IAMW20B - D.P.I.(H.K.) Limited
Click to zoom

Application Details

Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Date of Grant
Oct 31, 2020
Application Purpose
Original Equipment
Date of Application
Oct 31, 2020
Equipment Note
Wireless Mouse
Frequency Range
2405.00000000 - 2475.00000000
Company
D.P.I.(H.K.) Limited
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗
↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

User’s Manual IAMW20B Specification Wireless mouse, rubber coated cover 1000DPI USB connection plug and play Size 112*67*42mm net weight: 58g System support:98/me/2000/xp/Vista/Win7/8/10 How to use 1. Open the battery cover and put 2pcs AAA battery inside and close the cover; 2. Take on the button 3. Plug the the USB or Type C head to computer and play FCC Warning Statement Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: ‐‐ Reorient or relocate the receiving antenna. ‐‐ Increase the separation between the equipment and receiver. ‐‐ Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. ‐‐ Consult the dealer or an experienced radio/TV technician for help. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment

Cover Letter(s)

Oct 28, 2020 Equipment Autorisation Division Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 FCC ID: 2ATD3-IAMW20B Product Name: Wireless mouse Request for Confidentiality Pursuant to Sections 0.457 and 0.459 of the commissions rules, we hereby request that the following documents be held confidential: • Schematics • Block diagram • Operation description These materials contain trade secrets and proprietary information and are not customarily released to the public. The public disclosure of this information might be harmful to the company and provide unjustified benefits to our competitors. <Signature>: Name: Alan Tang Title:Manager Applicant Company:D.P.I (H.K.) Limited

Cover Letter(s)

Oct 28, 2020 Federal Communications Commission Authorization & Evaluation Division 7345 Oakland Mills Road Columbia, Maryland 21046 Authority to Act as Agent On our behalf, I appoint Shenzhen Timeway Testing Laboratories/ Zone C, 1st Floor, Zone C, 1st Floor, Block B, Jun Xiang Da Building, Zhongshan Park Road West, Tong Le Village, Nanshan District, Shenzhen, China (Name of Agent company name and address) to act as our agent in the preparation of this application for equipment certification. I certify that submitted documents properly describe the device or system for which equipment certification is sought. I also certify that each unit manufactured, imported or marketed, as defined in the Federal Communications Commission’s regulations will have affixed to it a label identical to that submitted for approval with this application. For instances where our authorized agent signs the application for certification on our behalf, I acknowledge that all responsibility for complying with the terms and conditions for certification, still resides with D.P.I.(H.K.) Limited / Unit 3903, 39/F., Cable TV tower, NO.9 Hol Shining Road, Tsuen Wan, N.T., Hong Kong <Signature>: Name: Alan Tang Title:Manager Applicant Company:D.P.I (H.K.) Limited

ID Label/Location Info

Label Location

RF Exposure Info

RF Exposure evaluation According to 447498 D01 General RF Exposure Guidance v05 The 1-g and 10-g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation distances ≤ 50 mm are determined by: [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance, mm)] ·[√f(GHz)] ≤ 3.0 for 1-g SAR and ≤ 7.5 for 10-g extremity SAR, where f(GHz) is the RF channel transmit frequency in GHz Power and distance are rounded to the nearest mW and mm before calculation The result is rounded to one decimal place for comparison eirp = pt x gt = (EXd) 2 /30 where: pt = transmitter output power in watts, gt = numeric gain of the transmitting antenna (unitless), E = electric field strength in V/m, --- 10 ((dBuV/m)/ 20) /10 6 d = measurement distance in meters (m)---3m So pt = (EXd) 2 /30 x gt Field strength = 92.48dBuV/m @3m Ant gain =-1.0dBi ;so Ant numeric gain= 0.794 So pt={ [10 ( 92.48 /20) /10 6 x3] 2 /30x0.794 }x1000 mW =0.67mW So (0.67 mW/5mm)x √2.475GHz = 0.21 <3 Then SAR evaluation is not required

Test Report

Report No.: TW2010053E File Reference No.: 2020-10-27 Applicant: D.P.I (H.K.) Limited Product: Wireless mouse Model No.: IAMW20B Brand Name: N/A Test Standards: FCC Part 15.249 Test Result: It is herewith confirmed and found to comply with the requirements set up by ANSI C63.4&FCC Part 15 Subpart C, Paragraph 15.249 regulations for the evaluation of electromagnetic compatibility Approved By Jack Chung Manager Dated: October 27, 2020 Results appearing herein relate only to the sample tested The technical reports is issued errors and omissions exempt and is subject to withdrawal at SHENZHEN TIMEWAY TESTING LABORATORIES Zone C, 1st Floor, Block B, Jun Xiang Da Building, Zhongshan Park Road West, Tong Le Village, Nanshan District, Shenzhen, China Tel (755) 83448688, Fax (755) 83442996, E-Mail:[email protected] Report No.: TW2010053E Page 2 of 37 Date: 2020-10-27 The report refers only to the sample tested and does not apply to the bulk. This report is issued in confidence to the client and it will be strictly treated as such by the SHENZHEN TIMEWAY TESTING LABORATORIES. It may not be reproduced rather in its entirety or in part and it may not be used for adverting. The client to whom the report is issued may, however, show or send it . or a certified copy there of prepared by the SHENZHEN TIMEWAY TESTING LABORATORIES. to his customer. Supplier or others persons directly concerned. SHENZHEN TIMEWAY TESTING LABORATORIES. will not, without the consent of the client enter into any discussion of correspondence with any third party concerning the contents of the report. In the event of the improper use of the report. The SHENZHEN TIMEWAY TESTING LABORATORIES. reserves the rights to withdraw it and to adopt any other remedies which may be appropriate. Special Statement: The testing quality ability of our laboratory meet with "Quality Law of People's Republic of China" Clause 19. The testing quality system of our laboratory meet with ISO/IEC-17025 requirements, which is approved by CNAS. This approval result is accepted by MRA of APLAC. Our test facility is recognized, certified, or accredited by the following organizations: CNAS-LAB Code: L2292 The EMC Laboratory has been assessed and in compliance with CNAS-CL01 accreditation criteria for testing Laboratories (identical to ISO/IEC 17025:2005 General Requirements) for the Competence of testing Laboratories. FCC-Registration No.: 744189 The EMC Laboratory has been registered and fully described in a report filed with the (FCC) Federal Communications commission. The acceptance letter from the FCC is maintained in our files. Registration No.: 744189. Industry Canada (IC) —Registration No.:5205A The EMC Laboratory has been registered by Certification and Engineering Bureau of Industry Canada for radio equipment testing with Registration No.: 5205A. A2LA (Certification Number:5013.01) The EMC Laboratory has been accredited by the American Association for Laboratory Accreditation (A2LA). Certification Number:5013.01 Report No.: TW2010053E Page 3 of 37 Date: 2020-10-27 The report refers only to the sample tested and does not apply to the bulk. This report is issued in confidence to the client and it will be strictly treated as such by the SHENZHEN TIMEWAY TESTING LABORATORIES. It may not be reproduced rather in its entirety or in part and it may not be used for adverting. The client to whom the report is issued may, however, show or send it . or a certified copy there of prepared by the SHENZHEN TIMEWAY TESTING LABORATORIES. to his customer. Supplier or others persons directly concerned. SHENZHEN TIMEWAY TESTING LABORATORIES. will not, without the consent of the client enter into any discussion of correspondence with any third party concerning the contents of the report. In the event of the improper use of the report. The SHENZHEN TIMEWAY TESTING LABORATORIES. reserves the rights to withdraw it and to adopt any other remedies which may be appropriate. Test Report Conclusion Content 1.0 General Details ............................................................................................. 4 1.1 Test Lab Details............................................................................................. 4 1.2 Applicant Details.............................................................................................. 4 1.3 Description of EUT .......................................................................................... 4 1.4 Submitted Sample............................................................................................. 4 1.5 Test Duration................................................................................................... 4 1.6 Test Uncertainty................................................................................................ 5 1.7 Test By......................................................................................................... 5 2.0 List of Measurement Equipment......................................................................... 6 3.0 Technical Details.......................................................................................... 7 4.0 EUT Modification............................................................................................. 7 5.0 Power Line Conducted Emission Test..................................................................... 8 5.1 Schematics of the Test....................................................................................... 8 5.2 Test Method and Test Procedure............................................................................ 8 5.3 Configuration of the EUT................................................................................. 8 5.4 EUT Operating Condition................................................................................. 9 5.5 Conducted Emission Limit.................................................................................. 9 5.6 Test Result.........................................…

Text truncated - open the document above for the full version.

Test Setup Photos

Radiated emission test view

Contact Information

Applicant

Alan Tang(Manager)
[email protected]0755-82378830Fax: 0755-82378830

Test Firm

Shenzhen Timeway Testing LaboratoriesTerry Tang
[email protected]+86-755-83448688

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz-
Confidentiality
Long Term

Other Applications from D.P.I.(H.K.) Limited

Truly Wire-Free Earbuds - FCC ID 2ATD3-IAEBT270 - D.P.I.(H.K.) Limited
2ATD3-IAEBT270

Truly Wire-Free Earbuds

Apr 06, 2020

Equipment Class

DTS - Digital Transmission System
Truly Wire-Free Earbuds - FCC ID 2ATD3-IAEBT300 - D.P.I.(H.K.) Limited
2ATD3-IAEBT300

Truly Wire-Free Earbuds

Jan 14, 2020

Equipment Class

DTS - Digital Transmission System