FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

Β© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Wings Mobile Telecom SL/
  3. 2ATQILW20

2ATQILW20Wings Light

Wings Mobile Telecom SL
Wings Light - FCC ID 2ATQILW20 - Wings Mobile Telecom SL
Click to zoom

Application Details

Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz
Date of Grant
Sep 20, 2020
Application Purpose
Original Equipment
Date of Application
Sep 17, 2020
Equipment Note
Wings Light
Frequency Range
0.11000000 - 0.20500000
Company
Wings Mobile Telecom SL
Country
Spain

Documents & Files

Select a file to view

Users Manual

β†—

Cover Letter(s)

β†—
β†—

External Photos

β†—

ID Label/Location Info

β†—

Internal Photos

β†—

RF Exposure Info

β†—

Test Report

β†—

Test Setup Photos

β†—

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1)This device may not cause harmful interference, and (2)this device must accept any interference received, (3)including interference that may cause undesired operation. Any Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to responsible for compliance could void the user's authority to operate the equipment. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: -Reorient or relocate the receiving antenna. -Increase the separation between the equipment and receiver.-Increase the separation between the equipment and receiver. -Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -Consult the dealer or an experienced radio/TV technician for help. Thisequi pment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body.20cm between the radiator & your body. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1)This device may not cause harmful interference, and (2)this device must accept any interference received, (3)including interference that may cause undesired operation. Any Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to responsible for compliance could void the user's authority to operate the equipment. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: -Reorient or relocate the receiving antenna. -Increase the separation between the equipment and receiver.-Increase the separation between the equipment and receiver. -Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -Consult the dealer or an experienced radio/TV technician for help. Thisequi pment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body.20cm between the radiator & your body. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1)This device may not cause harmful interference, and (2)this device must accept any interference received, (3)including interference that may cause undesired operation. Any Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to responsible for compliance could void the user's authority to operate the equipment. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: -Reorient or relocate the receiving antenna. -Increase the separation between the equipment and receiver.-Increase the separation between the equipment and receiver. -Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -Consult the dealer or an experienced radio/TV technician for help. Thisequi pment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body.20cm between the radiator & your body. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1)This device may not cause harmful interference, and (…

Text truncated - open the document above for the full version.

Cover Letter(s)

Wings Mobile Telecom SL 1/1 Letter of Authorization Company: Wings Mobile Telecom SL Address: c/Beethoven 15, piso 4, Barcelona, Spain Product Name: Wings Light Model Number: LW20 FCC Identifier: 2ATQILW20 We authorize LGAI Technological Center S.A., Ronda de la Font del Carme, s/n, 08193 Bellaterra, Spain, to act on our behalf on all matters concerning the above named equipment. Any individual within LGAI Technological Center S.A. is authorized to act on our behalf and take action on the application. We declare that authorize LGAI Technological Center S.A., Ronda de la Font del Carme, s/n, 08193 Bellaterra, Spain, is allowed to forward all information related to the approval project to the Federal Communication Commission and to discuss any issues concerning the approval application. Any and all acts carried out by LGAI Technological Center S.A. on our behalf shall have the same effect as acts of our own. Name: Antonio Milio Date: 2020-09-16 Title: Manager Signature of applicant:

Cover Letter(s)

Wings Mobile Telecom SL 1/1 Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 Date: 2020-09-16 Subject: Request for Confidentiality FCC ID: 2ATQILW20 To Whom It May Concern, Pursuant to the provisions of Sections 0.457 and 0.459 of Commission's rules (47CFR0.457, 0.459), we are requesting the Commission to withhold the following attachment(s) as confidential document from public disclosure. Exhibits Long-Term Confidentiality Short-Term Confidentiality NOTE 2 ID Label/Location No No Attestation Statement No No External Photos No ☐ Block Diagram β˜’ ☐ Schematics β˜’ ☐ Test Report No No Test Setup Photos No ☐ User’s Manual No ☐ Internal Photos No ☐ Parts List / Tune Up β˜’ ☐ RF Exposure Info No No Operational Description β˜’ ☐ Cover Letter(s) No No SDR Software / Security Info ☐ No NOTE 1: Long-Term Confidentiality may be permitted under special conditions (See II. LONG-TERM CONFIDENTIALITY, Section 3 of KDB 726920, use last in force) NOTE 2: Short-Term Confidentiality can be requested for a maximum of 180 days from the date of the grant. Above mentioned document contains detailed system and equipment description are considered as proprietary information in operation of the equipment. The public disclosure of above documents might be harmful to our company and would give competitor an unfair advantage in the market. It is our understanding that all measurement test reports, FCC ID label format and correspondent during certification review process cannot be granted as confidential documents and those information will be available for public review once the grant of equipment authorization is issued. Sincerely, Signature: Name: Antonio Milio Title: Manager

External Photos

FCC ID: 2ATQILW20

ID Label/Location Info

Size:10*20mm M/N: LW20 FCC ID: 2ATQILW20 This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:(1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Label location

Internal Photos

FCC ID: 2ATQILW20 antenna location

RF Exposure Info

Global United Technology Services Co., Ltd. No. 123-128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 1 of 4 FCC ID: 2ATQILW20 RF Exposure Evaluation 1 Measuring Standard KDB 680106 D01 RF Exposure Wireless Charging Apps v03 2 Requirements According to the item 5 of KDB 680106 D01v03: Inductive wireless power transfer applications that meet all of the following requirements are excluded from submitting an RF exposure evaluation. (1) Power transfer frequency is less than 1MHz. (2) Output power from each primary coil is less than or equal to 15 watts. (3) The transfer system includes only single primary and secondary coils. This includes charging systems that may have multiple primary coils and clients that are able to detect and allow coupling only between individual pairs of coils. (4) Client device is placed directly in contact with the transmitter. (5) Mobile exposure conditions only (portable exposure conditions are not covered by this exclusion). (6) The aggregate H-field strengths at 15 cm surrounding the device and 20 cm above the top surface from all simultaneous transmitting coils are demonstrated to be less than 50% of the MPE limit. Remark: Meet all the above requirements. Limits The criteria listed in the following table shall be used to evaluate the environment impact of human exposure to radio frequency (RF) radiation as specified in 1.1307(b) Limits for Maximum Permissible Exposure (MPE) Global United Technology Services Co., Ltd. No. 123-128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 2 of 4 3 Test Setup 4 Test Procedure 1) The RF exposure test was performed in anechoic chamber. 2) The measurement probe was placed at test distance (15 cm from all sides and 20 cm from the top) which is between the edge of the charger and the geometric center of probe. 3) The highest emission level was recorded and compared with limit as soon as measurement of each points (A, B, C, D, E) were completed. 4) The EUT was measured according to the dictates of KDB 680106 D01v03. Remark:The EUT’s test position A, B, C, D and E is valid for the E and H field measurements. Global United Technology Services Co., Ltd. No. 123-128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 3 of 4 5 Test Instruments list Test Equipment Manufacturer Model No. SN. Cal.Date (mm-dd-yy) Cal.Due date (mm-dd-yy) Exposure Level Tester Narda ELT-400 N-0231 June. 25 2020 June. 24 2021 Magnetic field probe 100cm 2 Narda ELT probe 100cm 2 M0675 June. 25 2020 June. 24 2021 6 Test Result E-Filed Strength at 15 cm from the edges surrounding the EUT (V/m) Frequency Range (MHz) Test Position A Test Position B Test Position C Test Position D Limits (V/m) 0.110-0.205 0.54 0.68 0.46 0.52 614 E-Filed Strength at 20 cm from the top of the EUT (V/m) Frequency Range (MHz) Test Position E Limits (V/m) 0.110-0.205 0.86 614 H-Filed Strength at 15 cm from the edges surrounding the EUT (A/m) Frequency Range (MHz) Test Position A Test Position B Test Position C Test Position D Limits (A/m) 0.110-0.205 0.12 0.23 0.14 0.25 1.63 H-Filed Strength at 20 cm from the top of the EUT (A/m) Frequency Range (MHz) Test Position E Limits (A/m) 0.110-0.205 0.22 1.63 Test Engineer: Reviewer: Global United Technology Services Co., Ltd. No. 123-128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 4 of 4 7 Test Set-up Photo

Test Report

Global United Technology Services Co., Ltd. Report No.: GTS202009000118F01 Authorized Signature: Robinson Lo Laboratory Manager This results shown in this test report refer only to the sample(s) tested, this test report cannot be reproduced, except in full, without prior written permission of the company. The report would be invalid without specific stamp of test institute and the signatures of compiler and approver. Page 1 of 31 TEST REPORT Applicant: Wings Mobile Telecom SL Address of Applicant: c/Beethoven 15, piso 4, Barcelona, Spain Manufacturer/Factory: Wings Mobile Telecom SL Address of Manufacturer/Factory: c/Beethoven 15, piso 4, Barcelona, Spain Equipment Under Test (EUT) Product Name: Wings Light Brand Name: Wings Mobile Model No.: LW20 FCC ID: 2ATQILW20 Applicable standards: FCC CFR Title 47 Part 15 Subpart C Date of sample receipt: Sep. 06, 2020 Date of Test: Sep. 06, 2020 - Sep. 16, 2020 Date of report issued: Sep. 16, 2020 Test Result : PASS * * In the configuration tested, the EUT complied with the standards specified above. Report No.: GTS202009000118F01 Global United Technology Services Co., Ltd. No. 123-128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 2 of 31 2 Version Version No. Date Description 00 Sep. 16, 2020 Original Prepared By: Date: Sep. 16, 2020 Project Engineer Check By: Date: Sep. 16, 2020 Reviewer Report No.: GTS202009000118F01 Global United Technology Services Co., Ltd. No. 123-128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 3 of 31 3 Contents Page 1 COVER PAGE ............................................................................................................................................ 1 2 VERSION .................................................................................................................................................. 2 3 CONTENTS .............................................................................................................................................. 3 4 TEST SUMMARY ..................................................................................................................................... 4 4.1 MEASUREMENT UNCERTAINTY ............................................................................................................ 4 5 GENERAL INFORMATION ...................................................................................................................... 5 5.1 GENERAL DESCRIPTION OF EUT ......................................................................................................... 5 5.2 TEST MODE ........................................................................................................................................ 6 5.3 DESCRIPTION OF SUPPORT UNITS ....................................................................................................... 6 5.4 TEST FACILITY ................................................................................................................................... 6 5.5 TEST LOCATION ................................................................................................................................. 6 5.6 OTHER INFORMATION REQUESTED BY THE CUSTOMER ......................................................................... 6 6 TEST INSTRUMENTS LIST ..................................................................................................................... 7 7 TEST RESULTS AND MEASUREMENT DATA ...................................................................................... 9 7.1 ANTENNA REQUIREMENT: ................................................................................................................... 9 7.2 CONDUCTED EMISSIONS ................................................................................................................... 10 7.3 SPURIOUS EMISSION......................................................................................................................... 13 7.4 20DB OCCUPY BANDWIDTH .............................................................................................................. 20 8 TEST SETUP PHOTO ............................................................................................................................ 22 9 EUT CONSTRUCTIONAL DETAILS ..................................................................................................... 24 Report No.: GTS202009000118F01 Global United Technology Services Co., Ltd. No. 123-128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 4 of 31 4 Test Summary Test Item Section in CFR 47 Result Antenna requirement 15.203 Pass AC Power Line Conducted Emission 15.207 Pass Spurious Emission 15.209(a)(f) Pass 20dB Bandwidth 15.215 Pass Pass: The EUT complies with the essential requirements in the standard. 4.1 Measurement Uncertainty Test Item Frequency Range Measurement Uncertainty Notes Radiated Emission 30MHz-200MHz 3.8039dB (1) Radiated Emission 200MHz-1GHz 3.9679dB (1) Radiated Emission 1GHz-18GHz 4.29dB (1) Radiated Emission 18GHz-40GHz 3.30dB (1) AC Power Line Conducted Emission 0.15MHz ~ 30MHz 3.44dB (1) Note (1): The measurement uncertainty is for coverage factor of k=2 and a level of confidence of 95%. Report No.: GTS202009000118F01 Global United Technology Services Co., Ltd. No. 123-128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 5 of 31 5 General Information 5.1 General Description …

Text truncated - open the document above for the full version.

Test Setup Photos

Radiated Emission FCC ID: 2ATQILW20 Conducted Emissions MPE

Contact Information

Applicant

Antonio Milio(Manager)
[email protected]+34658224081Fax: +34658224081

Technical Contact

Global United Technology Services Co. Ltd.robinson lo
[email protected]86-0-755-2779-8480

Shenzhen Β· China

Test Firm

Global United Technology Services Co. Ltd.Robinson Lo
[email protected]86-0-755-2779-8480Fax: 86-0-755-27798960

Technical Specifications

#Rule PartsFrequency RangePower Output
115C0.11 MHz - 0.205 MHz-
Confidentiality
Long Term

Other Applications from Wings Mobile Telecom SL

Headphones - FCC ID 2ATQI-HS - Wings Mobile Telecom SL
2ATQI-HS

Headphones

Jan 26, 2021

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
Bluetooth earphone - FCC ID 2ATQI-WSE01 - Wings Mobile Telecom SL
2ATQI-WSE01

Bluetooth earphone

Jan 12, 2021

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
2.1 CH SPEAKER - FCC ID 2ATQI-HI-FICLASSIC - Wings Mobile Telecom SL
2ATQI-HI-FICLASSIC

2.1 CH SPEAKER

Nov 03, 2020

Equipment Class

DWM - Part 15 Wireless Microphone
2.1 CH SPEAKER - FCC ID 2ATQI-CLASSIC - Wings Mobile Telecom SL
2ATQI-CLASSIC

2.1 CH SPEAKER

Oct 27, 2020

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
2.1 CH SPEAKER - FCC ID 2ATQI-TECH - Wings Mobile Telecom SL
2ATQI-TECH

2.1 CH SPEAKER

Oct 27, 2020

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter