Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
115-205KHz115-205KHz Warning Statement This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Any Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: -Reorient or relocate the receiving antenna. -Increase the separation between the equipment and receiver. -Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -Consult the dealer or an experienced radio/TV technician for help. This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body.
(20 2 ME T 914 Balt RE: To W We , to a inclu We sub j the Thi s Sin c Cli e Clie Con c/B 20/09/21) T Laborator 4 West Pata timore, MD LETTER O Whom It Ma , the unders act on our be uding the si also hereby ject to the d Anti-Drug A s agreemen cerely, ent’s signatu ent’s name ntact inform eethoven ries, Inc. apsco Avenu 21230 OF AGENT ay Concern signed, here ehalf in all m igning of all y certify tha denial of be Abuse Act o nt expires on ure : e / title : An mation / ad 15, piso 4, Wings M Agent A ue AUTHORI Z : eby authori matters rela documents at no party t nefits, inclu of 1988, 21 ne year from tonio Milio ddress: Barcelona Mobile Tele Authorizatio ZATION ze (Global ating to app s relating to to the applic uding FCC b U.S.C.853( m the curre o / Manage a,Spain ecom SL on Letter United Tec lication for e o these matt cation autho benefits, pu (a). nt date. er hnology Se equipment a ters. orized hereu rsuant to Se ervices Co., authorizati o under is ection 530 1 Ltd.) on, 1 of
Global United Technology Services Co., Ltd. Report No.: GTS202009000139F01 Authorized Signature: Robinson Lo Laboratory Manager This results shown in this test report refer only to the sample(s) tested, this test report cannot be reproduced, except in full, without prior written permission of the company. The report would be invalid without specific stamp of test institute and the signatures of compiler and approver. Page 1 of 25 TEST REPORT Applicant: Wings Mobile Telecom SL Address of Applicant: c/Beethoven 15, piso 4,Barcelona,Spain Manufacturer/Factory: Shenzhen Yoyo Industrial Co.,Ltd. Address of Manufacturer/Factory: 4th. fl. Bldg. A, Xinlihua Ind. Park, LongGang District, Shenzhen, China Equipment Under Test (EUT) Product Name: Wireless car charger Model No.: Wings Charger Q1, Wings Charger Q12 FCC ID: 2ATQIQ1 Applicable standards: FCC CFR Title 47 Part 15 Subpart C Date of sample receipt: September 09, 2020 Date of Test: September 09- September 17, 2020 Date of report issued: September 17, 2020 Test Result : PASS * * In the configuration tested, the EUT complied with the standards specified above. Report No.: GTS202009000139F01 Global United Technology Services Co., Ltd. No. 123-128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 2 of 25 2 Version Version No. Date Description 00 September 17, 2020 Original Prepared By: Date: September 17, 2020 Project Engineer Check By: Date: September 17, 2020 Reviewer Report No.: GTS202009000139F01 Global United Technology Services Co., Ltd. No. 123-128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 3 of 25 3 Contents Page 1 COVER PAGE ............................................................................................................................................ 1 2 VERSION .................................................................................................................................................. 2 3 CONTENTS .............................................................................................................................................. 3 4 TEST SUMMARY ..................................................................................................................................... 4 4.1 MEASUREMENT UNCERTAINTY ............................................................................................................ 4 5 GENERAL INFORMATION ...................................................................................................................... 5 5.1 GENERAL DESCRIPTION OF EUT ......................................................................................................... 5 5.2 TEST MODE ........................................................................................................................................ 6 5.3 DESCRIPTION OF SUPPORT UNITS ....................................................................................................... 6 5.4 TEST FACILITY .................................................................................................................................... 6 5.5 TEST LOCATION ................................................................................................................................. 6 5.6 OTHER INFORMATION REQUESTED BY THE CUSTOMER ......................................................................... 6 6 TEST INSTRUMENTS LIST ..................................................................................................................... 7 7 TEST RESULTS AND MEASUREMENT DATA ...................................................................................... 9 7.1 ANTENNA REQUIREMENT: .................................................................................................................... 9 7.2 CONDUCTED EMISSIONS ................................................................................................................... 10 7.3 SPURIOUS EMISSION ......................................................................................................................... 13 7.4 20DB OCCUPY BANDWIDTH .............................................................................................................. 18 8 TEST SETUP PHOTO ............................................................................................................................ 19 9 EUT CONSTRUCTIONAL DETAILS ..................................................................................................... 21 Report No.: GTS202009000139F01 Global United Technology Services Co., Ltd. No. 123-128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 4 of 25 4 Test Summary Test Item Section in CFR 47 Result Antenna requirement 15.203 Pass AC Power Line Conducted Emission 15.207 Pass Spurious Emission 15.209(a)(f) Pass 20dB Bandwidth 15.215 Pass Pass: The EUT complies with the essential requirements in the standard. 4.1 Measurement Uncertainty Test Item Frequency Range Measurement Uncertainty Notes Radiated Emission 30MHz-200MHz 3.8039dB (1) Radiated Emission 200MHz-1GHz 3.9679dB (1) Radiated Emission 1GHz-18GHz 4.29dB (1) Radiated Emission 18GHz-40GHz 3.30dB (1) AC Power Line Conducted Emission 0.15MHz ~ 30MHz 3.44dB (1) Note (1): The measurement uncertainty is for coverage factor of k=2 and a level of confidence of 95%. Report No.: GTS202009000139F01 Global United Technology Services Co., Ltd. No. 123-128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fa…
Text truncated - open the document above for the full version.
(20 2 ME T 914 Balt RE: Q1, To W req u revi Th e cust harm Ple a Sin c Cli e Clie Con c/B 20-09-21) T Laborator 4 West Pata timore, MD CONFIDE Wings Ch Whom It Ma - This let and 0.4 - - Block D - Schem a - Operati uired to be ew. e above mat tomarily rel mful to the a ase contact cerely, ent’s signatu ent’s name ntact inform eethoven Long ries, Inc. apsco Avenu 21230 NTIALITY R arger Q12 ay Concern tter serves a 459 of CFR Diagram atics ional Descr submitted terials conta eased to th applicant an t me if there ure : e / title : An mation / ad 15, piso 4, Wings M Term Con ue REQUEST / 2ATQIQ1 : as an officia 47. We ha iption with this a ain trade se e public. Th nd provide u e is any info tonio Milio ddress: Barcelona Mobile Tele nfidentiality FOR (Wire ) al request fo ve requeste application ecrets and p he public dis unjustified b ormation you o a,Spain ecom SL y Request L less car ch or confident ed that the be perman proprietary i sclosure of benefits to i u may need Letter harger / Win tiality under ently withh nformation these mat e ts competito d. ngs Charg r sections 0 eld from p u not erials may b tors. er .457 ublic be
Report No.: GTS202009000139 Global United Technology Services Co., Ltd. No. 123-128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 21 of 25 9 EUT Constructional Details Report No.: GTS202009000139 Global United Technology Services Co., Ltd. No. 123-128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 22 of 25 Report No.: GTS202009000139 Global United Technology Services Co., Ltd. No. 123-128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 23 of 25
2cm Model: Wings Charger Q1 FCC ID: 2ATQIQ1 This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2)this device must accept any interference received, including interference that may causeundesired operation. Label Location 1cm
Report No.: GTS202009000139 Global United Technology Services Co., Ltd. No. 123-128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 24 of 25 TX ANT Report No.: GTS202009000139 Global United Technology Services Co., Ltd. No. 123-128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 25 of 25 ------End------
Global United Technology Services Co., Ltd. No. 123-128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 1 of 4 FCC ID: 2ATQIQ1 RF Exposure Evaluation 1 Measuring Standard KDB 680106 D01 RF Exposure Wireless Charging Apps v03 2 Requirements According to the item 5 of KDB 680106 D01v03: Inductive wireless power transfer applications that meet all of the following requirements are excluded from submitting an RF exposure evaluation. (1) Power transfer frequency is less than 1MHz. (2) Output power from each primary coil is less than or equal to 15 watts. (3) The transfer system includes only single primary and secondary coils. This includes charging systems that may have multiple primary coils and clients that are able to detect and allow coupling only between individual pairs of coils. (4) Client device is placed directly in contact with the transmitter. (5) Mobile exposure conditions only (portable exposure conditions are not covered by this exclusion). (6) The aggregate H-field strengths at 15 cm surrounding the device and 20 cm above the top surface from all simultaneous transmitting coils are demonstrated to be less than 50% of the MPE limit. Remark: Meet all the above requirements. Limits The criteria listed in the following table shall be used to evaluate the environment impact of human exposure to radio frequency (RF) radiation as specified in 1.1307(b) Limits for Maximum Permissible Exposure (MPE) Global United Technology Services Co., Ltd. No. 123-128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 2 of 4 3 Test Setup 4 Test Procedure 1) The RF exposure test was performed in anechoic chamber. 2) The measurement probe was placed at test distance (15 cm from all sides and 20 cm from the top) which is between the edge of the charger and the geometric center of probe. 3) The highest emission level was recorded and compared with limit as soon as measurement of each points (A, B, C, D, E) were completed. 4) The EUT was measured according to the dictates of KDB 680106 D01v03. Remark:The EUT’s test position A, B, C, D and E is valid for the E and H field measurements. Global United Technology Services Co., Ltd. No. 123-128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 3 of 4 5 Test Instruments list Test Equipment Manufacturer Model No. SN. Cal.Date (mm-dd-yy) Cal.Due date (mm-dd-yy) Exposure Level Tester Narda ELT-400 N-0231 June. 25 2020 June. 24 2021 Magnetic field probe 100cm 2 Narda ELT probe 100cm 2 M0675 June. 25 2020 June. 24 2021 6 Test Result E-Filed Strength at 15 cm from the edges surrounding the EUT (V/m) Frequency Range (MHz) Test Position A Test Position B Test Position C Test Position D Limits (V/m) 0.1115-0.205 1.35 2.00 0.85 0.77 614 E-Filed Strength at 20 cm from the top of the EUT (V/m) Frequency Range (MHz) Test Position E Limits (V/m) 0.1115-0.205 1.56 614 H-Filed Strength at 15 cm from the edges surrounding the EUT (A/m) Frequency Range (MHz) Test Position A Test Position B Test Position C Test Position D Limits (A/m) 0.1115-0.205 0.35 0.56 0.71 0.74 1.63 H-Filed Strength at 20 cm from the top of the EUT (A/m) Frequency Range (MHz) Test Position E Limits (A/m) 0.1115-0.205 0.43 1.63 Test Engineer: Reviewer: Global United Technology Services Co., Ltd. No. 123-128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 4 of 4 7 Test Set-up Photo
Global United Technology Services Co., Ltd. Report No.: GTS202009000139F01 Authorized Signature: Robinson Lo Laboratory Manager This results shown in this test report refer only to the sample(s) tested, this test report cannot be reproduced, except in full, without prior written permission of the company. The report would be invalid without specific stamp of test institute and the signatures of compiler and approver. Page 1 of 25 TEST REPORT Applicant: Wings Mobile Telecom SL Address of Applicant: c/Beethoven 15, piso 4,Barcelona,Spain Manufacturer/Factory: Shenzhen Yoyo Industrial Co.,Ltd. Address of Manufacturer/Factory: 4th. fl. Bldg. A, Xinlihua Ind. Park, LongGang District, Shenzhen, China Equipment Under Test (EUT) Product Name: Wireless car charger Model No.: Wings Charger Q1, Wings Charger Q12 FCC ID: 2ATQIQ1 Applicable standards: FCC CFR Title 47 Part 15 Subpart C Date of sample receipt: September 09, 2020 Date of Test: September 09- September 17, 2020 Date of report issued: September 17, 2020 Test Result : PASS * * In the configuration tested, the EUT complied with the standards specified above. Report No.: GTS202009000139F01 Global United Technology Services Co., Ltd. No. 123-128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 2 of 25 2 Version Version No. Date Description 00 September 17, 2020 Original Prepared By: Date: September 17, 2020 Project Engineer Check By: Date: September 17, 2020 Reviewer Report No.: GTS202009000139F01 Global United Technology Services Co., Ltd. No. 123-128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 3 of 25 3 Contents Page 1 COVER PAGE ............................................................................................................................................ 1 2 VERSION .................................................................................................................................................. 2 3 CONTENTS .............................................................................................................................................. 3 4 TEST SUMMARY ..................................................................................................................................... 4 4.1 MEASUREMENT UNCERTAINTY ............................................................................................................ 4 5 GENERAL INFORMATION ...................................................................................................................... 5 5.1 GENERAL DESCRIPTION OF EUT ......................................................................................................... 5 5.2 TEST MODE ........................................................................................................................................ 6 5.3 DESCRIPTION OF SUPPORT UNITS ....................................................................................................... 6 5.4 TEST FACILITY .................................................................................................................................... 6 5.5 TEST LOCATION ................................................................................................................................. 6 5.6 OTHER INFORMATION REQUESTED BY THE CUSTOMER ......................................................................... 6 6 TEST INSTRUMENTS LIST ..................................................................................................................... 7 7 TEST RESULTS AND MEASUREMENT DATA ...................................................................................... 9 7.1 ANTENNA REQUIREMENT: .................................................................................................................... 9 7.2 CONDUCTED EMISSIONS ................................................................................................................... 10 7.3 SPURIOUS EMISSION ......................................................................................................................... 13 7.4 20DB OCCUPY BANDWIDTH .............................................................................................................. 18 8 TEST SETUP PHOTO ............................................................................................................................ 19 9 EUT CONSTRUCTIONAL DETAILS ..................................................................................................... 21 Report No.: GTS202009000139F01 Global United Technology Services Co., Ltd. No. 123-128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 4 of 25 4 Test Summary Test Item Section in CFR 47 Result Antenna requirement 15.203 Pass AC Power Line Conducted Emission 15.207 Pass Spurious Emission 15.209(a)(f) Pass 20dB Bandwidth 15.215 Pass Pass: The EUT complies with the essential requirements in the standard. 4.1 Measurement Uncertainty Test Item Frequency Range Measurement Uncertainty Notes Radiated Emission 30MHz-200MHz 3.8039dB (1) Radiated Emission 200MHz-1GHz 3.9679dB (1) Radiated Emission 1GHz-18GHz 4.29dB (1) Radiated Emission 18GHz-40GHz 3.30dB (1) AC Power Line Conducted Emission 0.15MHz ~ 30MHz 3.44dB (1) Note (1): The measurement uncertainty is for coverage factor of k=2 and a level of confidence of 95%. Report No.: GTS202009000139F01 Global United Technology Services Co., Ltd. No. 123-128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fa…
Text truncated - open the document above for the full version.
Report No.: GTS202009000139 Global United Technology Services Co., Ltd. No. 123-128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 19 of 25 8 Test Setup Photo Report No.: GTS202009000139 Global United Technology Services Co., Ltd. No. 123-128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 20 of 25
2nd Floor, Block No.2, Laodong Industrial Zone · Shenzhen, Guangdong · China
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 0.115 MHz - 0.205 MHz | - |

Headphones
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Bluetooth earphone
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
2.1 CH SPEAKER
Equipment Class
DWM - Part 15 Wireless Microphone
2.1 CH SPEAKER
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
2.1 CH SPEAKER
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter