FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Wuhan Qiwu Technology Co., Ltd./
  3. 2AU4M-HR70

2AU4M-HR70Heart Rate

Wuhan Qiwu Technology Co., Ltd.
Heart Rate - FCC ID 2AU4M-HR70 - Wuhan Qiwu Technology Co., Ltd.
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Mar 05, 2023
Application Purpose
Original Equipment
Date of Application
Mar 05, 2023
Equipment Note
Heart Rate
Frequency Range
2457.00000000 - 2457.00000000
Company
Wuhan Qiwu Technology Co., Ltd.
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗
↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

WWAARRNNIINNGG This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: -- Reorient or relocate the receiving antenna. -- Increase the separation between the equipment and receiver. -- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -- Consult the dealer or an experienced radio/TV technician for help. The device has been evaluated to meet general RF exposure requirement. The device can be used in portable exposure condition without restriction FCC ID: 2AU4M-HR70 WARNING Manufacturer's Name: Wuhan Qiwu Technology Co.,Ltd. Address: 3 / F, Creative workshop, No.04, District D, Creative world, No.16 Yezhihu West Road, Hongshan District, Wuhan City, Hubei Province, China. Product Name: Heart Rate Model number: HR70,HR70S, HR70P, HR70C, HR70 PLUS, HR70 PRO This product can be used across all EU member states. Hereby, Wuhan Qiwu Technology Co.,Ltd. declares that this BIKE SMART COMPUTER product is in compliance with the essential requirements and other relevant provisions of Directive 2014/53/EU. A copy of the Declaration of Conformity can be found at Website: www.igpsport.cn CAUTION: RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE. DISPOSE OF USED BATTERIES ACCORDING TO THE INSTRUCTIONS Care for the environment! Must not be discarded with household waste! For RF Specification SPEClFlCATlONS: Operating Temperature: -10°C-50°C Function Operation Frequency Max RF outputpower: Limit BLE(1M) 2402MHz–2480MHz -3.56dBm 20 dBm. 2402MHz–2480MHz -3.47dBm 20 dBm. ANT+(1M) -3.23dBm 20 dBm. BLE(2M) 2457MHz ANT+(2M) 2457MHz -3.47dBm 20 dBm.

Attestation Statements

Rev 1/26/2023 (Wuhan Qiwu Technology Co., Ltd.) Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: 2/27/2023 Ref: Attestation Statements Part 2.911(d)(5)(i) Filing FCC ID: 2AU4M-HR70 [Wuhan Qiwu Technology Co., Ltd.] (“the applicant”) certifies that the equipment for which authorization is sought is not“covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. Sincerely, (Applicantsignature) (Applicant printed name) cai Li Rev 1/26/2023 (Wuhan Qiwu Technology Co., Ltd.) Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: 02-27-2023 Ref: Attestation Statements Part 2.911(d)(5)(ii) Filing FCC ID: 2AU4M-HR70 [Wuhan Qiwu Technology Co., Ltd.] (“the applicant”) certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. Sincerely, (Applicant signature) (Applicant printed name) cai Li

Attestation Statements

Wuhan Qiwu Technology Co.,Ltd. 3 / F, Creative workshop, No.04, District D, Creative world, No.16 Yezhihu West Road, Hongshan District, Wuhan City, Hubei Province, China. Date: 2/15/2023 FCC ID: 2AU4M-HR70 Model Number: HR70,HR70S, HR70P, HR70C, HR70 PLUS, HR70 PRO To: Federal Communication Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21048 To Whom It May Concern, We, Wuhan Qiwu Technology Co.,Ltd., declare that this EUT (FCC ID: 2AU4M-HR70) will conduct FCC compliance testing, the SDOC part recognized test lab(Shenzhen NTEK Testing Technology Co., Ltd.( ShenZhen Lab.). 1/F, Building E, Fenda Science Park, Sanwei Community,Xixiang Street Bao’an District, Shenzhen 518126 P.R. China) Please contact me if you have any question. Sincerely, Signature 2/15/2023 cai Li E-mail: [email protected] Phone: 027-87835568 Fax: 027-87835568 Address: 3 / F, Creative workshop, No.04, District D, Creative world, No.16 Yezhihu West Road, Hongshan District, Wuhan City, Hubei Province, China.

Attestation Statements

Wuhan Qiwu Technology Co., Ltd. U.S. Agent Letter of Attestation To: Federal Communications Commission 7435 Oakland Mills Road, Columbia, MD 21046, USA Date: 02-24-2023 Ref: Attestation Statement – Part2.911(d)(7) filing FCC ID: 2AU4M-HR70 Wuhan Qiwu Technology Co., Ltd. (“the applicant”) certifies that, as of the date of the filing of the application, THREE STONES MEDIA LLC(“the agent”) is our designated U.S. agent for service of process for the abovereference FCC ID. The applicant accepts to maintain an agent for service of process in the United States forno less than one year after either the grantee has permanently terminated all marketing and importation of theapplicable equipment within the U.S., or the conclusion of any Commission-related administrative or judicialproceeding involving the equipment, whichever is later. The applicant further acknowledges it is ourresponsibility to inform the FCC whenever the agent information changes. THREE STONES MEDIA LLC ("the agent) understand it is the agent's obligation to accept service of process in the United States for matters related to the applicable equipment, and at the physical U.S. address and email address. Designated U.S. Agent Company Name: THREE STONES MEDIA LLC FRN: 0033401761 GC: 2A99E Address: 1200 Broadway St. APT 329, Los Angeles, CA90015 Signature: Contact Person: Sijie Zhang Tel: +1 267 909 3692 Email: [email protected] Applicant Company Name: Wuhan Qiwu Technology Co., Ltd. Address: 3 / F, Creative workshop, No.04, District D, Creative world, No.16 Yezhihu West Road, Hongshan District, Wuhan City, Hubei Province, China. Signature: Contact Person: cai Li Tel: 027-87835568 Email: [email protected]

Cover Letter(s)

Wuhan Qiwu Technology Co., Ltd. Family models declaration letter. 3/3/2023 We Wuhan Qiwu Technology Co., Ltd. Of 3 / F, Creative workshop, No.04, District D, Creative world, No.16 Yezhihu West Road, Hongshan District, Wuhan City, Hubei Province, China. Product: Heart Rate Model Name: HR70,HR70S, HR70P, HR70C, HR70 PLUS, HR70 PRO Trade mark: iGPSPORT All models are the same circuit and RF module, except the model name. Thanks Sincerely, Signature 3/3/2023 cai Li E-mail: [email protected] Phone: 027-87835568 Fax: 027-87835568 Address: 3 / F, Creative workshop, No.04, District D, Creative world, No.16 Yezhihu West Road, Hongshan District, Wuhan City, Hubei Province, China.

Cover Letter(s)

H:\电磁兼容部\RF项目组\RF项目\2022\12月\S22122300809001 武汉齐物科技有限公司 心率带 HR70 FCC ID RF\6. Submission\Letter\FCC POA Letter.docx (Wuhan Qiwu Technology Co., Ltd.) Federal Communications Commission Authorization and Evaluation Division 1435 Oakland Mills Road Columbia, MD 21046 Date: 2/15/2023 SUBJECT: FCC Application for FCC ID: 2AU4M-HR70 To Whom It May Concern: We, the undersigned, hereby authorize Alex Li at Shenzhen NTEK Testing Technology Co., Ltd. on our behalf, to apply to the Federal Communications Commission on our equipment. Any and all acts carried out by Shenzhen NTEK Testing Technology Co., Ltd. on our behalf shall have the same effect as acts of our own. This is to advise that we are in full compliance with the Anti- Drug Abuse Act. We, the applicant, are not subject to a denial of federal benefits pursuant to Section 5301 of the Anti-Drug Act of 1988, 21 USC853a, and no party to the application is subject to a denial of federal benefits pursuant to that section. Regards, (signature) (printed name): cai Li

Cover Letter(s)

Wuhan Qiwu Technology Co., Ltd. Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 USA Date: 2/15/2023 Subject; Request for Confidentiality FCC ID: 2AU4M-HR70 To Whom It May Concern, Pursuant to the provisions of the Commission’s rules Title 47 Sections §0.457 and §0.459, we are requesting the Commission to withhold the following attachment(s) as confidential documents from public disclosure indefinitely. These documents contain detailed system and equipment descriptions and are considered as proprietary information in operation of the equipment. The public disclosure of these documents might be harmful to our company and would give competitors an unfair advantage in the market. Schematic Diagram Block Diagram Parts List Operational Description Tune-up Procedure In additional to above mentioned documents, in order to comply with the marketing regulations in Title 47 CFR §2.803 and the importation rules in Title 47 CFR §2.1204, while ensuring that business sensitive information remains confidential until the actual marketing of newly authorized devices, we request Short Term Confidentiality of the following attachment(s); External Photos Test Setup Photos Internal Photos User Manual For 45 days, pursuant to Public Notice DA 04-1705. OR For 180 days pursuantto KDB 726920 D01. It is our understanding that all measurement test reports, FCC ID label format and correspondence during the certification review process cannot be granted as confidential documents and this information will be available for public review once the grant of equipment authorization is issued. Sincerely, Signature: Name: cai Li Title: Manager Email: [email protected]

External Photos

ATTACHMENT PHOTOGRAPHS OF EUT Photo 1 Photo 2 Photo 3 Photo 4 Photo 5 Photo 6

Internal Photos

Photo 7 Photo 8 Photo 9 Photo 10 Photo 11 Photo 12 ANT Photo 13 Photo 14

RF Exposure Info

FCC ID: 2AU4M-HR70 Portable device According to §15.247(e)(i) and §1.1307(b)(1), systems operating under the provisions of this section shall be operated in a manner that ensures that the public is not exposed to radio frequency energy level in excess of the Commission’s guidelines. According to KDB447498 D01 General RF Exposure Guidance V06 The 1-g SAR and 10-g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation distances ≤ 50 mm are determined by: [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance, mm)]·[√f(GHZ)] ≤ 3.0 for 1-g SAR and ≤ 7.5 for 10-g extremity SAR, where: • f(GHZ) is the RF channel transmit frequency in GHz • Power and distance are rounded to the nearest mW and mm before calculation • The result is rounded to one decimal place for comparison When the minimum test separation distance is < 5 mm, a distance of 5 mm is applied to determine SAR test exclusion. BLE: Modulation Channel Freq. (GHz) Conduct ed power (dBm) Conducte d power (mW) Tune-up power (dBm) Max tune-up power (dBm) Max tune-up power (mW) Distance (mm) Result calculatio n SAR Exclusion threshold SAR test exclusion 2.402-2.17 0.61-2±1-10.79<50.246223.00YES 2.440-2.39 0.58-2±1-10.79<50.248163.00YES 2.480-2.66 0.54-2±1-10.79<50.250183.00YES 2.402-2.09 0.62-2±1-10.79<50.246223.00YES 2.440-2.29 0.59-2±1-10.79<50.248163.00YES 2.480-2.59 0.55-2±1-10.79<50.250183.00YES BLE(2M) BLE(1M) ANT: Modulation Channel Freq. (GHz) Conduct ed power (dBm) Conducte d power (mW) Tune-up power (dBm) Max tune-up power (dBm) Max tune-up power (mW) Distance (mm) Result calculatio n SAR Exclusion threshold SAR test exclusion ANT+ 1M 2.457-2.36 0.58-2±1-10.79<50.249023.00YES ANT+ 2M 2.457-2.31 0.59-2±1-10.79<50.249023.00YES Note: This product does not support the requirements under BT/ANT transmission simultaneous Conclusion: For the max result : 0.25018 ≤ 3.0 for 1g SAR, SAR is not required. Signature: Date: 2023-02-27 NAME AND TITLE (Please print or type): Alex li /Manager COMPANY (Please print or type): Shenzhen NTEK Testing Technology Co., Ltd./ 1/F, Building E, Fenda Science Park, Sanwei Community, Xixiang Street Bao’an District, Shenzhen P.R. China.

Test Report

Persisting in Technology antenna solutions for wireless technologies HR70 Antenna Evaluating Report 耀登电通科技(昆山)有限公司 Auden Communications&Multimedia Techno (Kunshan) Co., Ltd 1 Prepared By: WeifanFan Checked By:Jianjun Mao Date of Report: 2022/9/9 Company Confidential, Auden Many aspects of this presentation are protected by US, TW, CN and international patents and patent applications LIST OF TEST EQUIPMENTS ItemKind of EquipmentManufacturerType No.Last calibrationCalibrated until Calibration period 1Spectrum AnalyzerAgilentE5071C2022.05.102023.06.091 year 22G/3G Communications Test Set Agilent89602022.05.102023.06.091 year 3LTE Wireless Communications Test Set Anritsu MT88202022.05.102023.06.091 year 4TD Communications Test Set StarPointSP60102022.05.102023.06.091 year 5WIFI Wireless Communications Test Set Anritsu MT88602022.05.102023.06.091 year 6GPS SignalAgilent E4438C2022.05.102023.06.091 year 7ChamberGTSRayzone18 00 2022.05.102023.06.091 year Company Confidential, Auden Many aspects of this presentation are protected by US, TW, CN and international patents and patent applications Test set-up Company Confidential, Auden Many aspects of this presentation are protected by US, TW, CN and international patents and patent applications Test Standards According to the specifications of the manufacturer, it must comply with the requirements of the following standards: ANSI/IEEE Std 149-2008 Company Confidential, Auden Many aspects of this presentation are protected by US, TW, CN and international patents and patent applications Test Produce The method is used to measure the antenna 3D GAIN of EUT in OTA qualified Rayzone1800chamber. Equipment Under Test(EUT) geometry centre vertical projection at the centre of platform, the distance from EUT to measurement antenna is 1m. Company Confidential, Auden Many aspects of this presentation are protected by US, TW, CN and international patents and patent applications Frequency Range 6 使用系统Band使用系统Band GSMWIFI / BT2.4G~2.5G WCDMA全球定位GPS/BD TD-SCDMAFM CDMAOthers FDD LTE TDD LTE Company Confidential, Auden Many aspects of this presentation are protected by US, TW, CN and international patents and patent applications Machine picture 此处电感断开 Company Confidential, Auden Many aspects of this presentation are protected by US, TW, CN and international patents and patent applications BT passive standing wave and efficiency FrequencyEfficiency Total (%) Gain Total (dBi) 2.4G28.18 -1.53 2.41G29.31 -1.39 2.42G32.28 -0.98 2.43G33.11 -0.9 2.44G33.65 -0.79 2.45G37.33 -0.32 2.46G36.73 -0.32 2.47G35.73 -0.46 2.48G36.48 -0.39 2.49G34.99 -0.7 2.5G33.73 -0.82 Company Confidential, Auden Many aspects of this presentation are protected by US, TW, CN and international patents and patent applications BT passive standing wave and efficiency 2.5GHzUp-Down View 2.5GHzLeft-Right View2.5GHzFront-Back View 2.4GHzUp-Down View 2.4GHzLeft-Right View2.4GHzFront-Back View Company Confidential, Auden Many aspects of this presentation are protected by US, TW, CN and international patents and patent applications BT antenna 2D diagram Company Confidential, Auden Many aspects of this presentation are protected by US, TW, CN and international patents and patent applications Thank You AUDENASPIRE UPGRADE DEVOTE EXCELLENCE NAVIGATOR 11 AUDEN Techno Corp. Taiwan TEL:886-3-363-1901 No.19 Lane 772, Ho Ping Road Bade City, TaoyuanHsien, Taiwan. AUDEN communications & Multimedia Techno (Kunshan) Co. Ltd. TEL: 86 512 5764 6998 No.15 Ying-bingRd LuyangTown Kun Shan Jiang Su China

Test Report

Report No.: S22122300809001 Version.1.3 Page 1 of 61 RADIO TEST REPORT FCC ID: 2AU4M-HR70 Product: Heart Rate Trade Mark: iGPSPORT Model No.: HR70 Family Model: HR70S, HR70P, HR70C, HR70 PLUS, HR70 PRO Report No.: S22122300809001 Issue Date: Feb 02,2023 Prepared for Wuhan Qiwu Technology Co., Ltd. 3 / F, Creative workshop, No.04, District D, Creative world, No.16 Yezhihu West Road, Hongshan District, Wuhan City, Hubei Province, China. Prepared by Shenzhen NTEK Testing Technology Co., Ltd. 1/F, Building E, Fenda Science Park, Sanwei Community, Xixiang Street Bao’an District, Shenzhen 518126 P.R. China Tel:400-800-6106,0755-2320 0050 / 2320 0090 Website: http://www.ntek.org.cn Report No.: S22122300809001 Version.1.3 Page 2 of 61 TABLE OF CONTENTS 1 TEST RESULT CERTIFICATION ...................................................................................................................... 3 2 SUMMARY OF TEST RESULTS ......................................................................................................................... 4 3 FACILITIES AND ACCREDITATIONS ............................................................................................................. 5 3.1 FACILITIES..................................................................................................................................................... 5 3.2 LABORATORY ACCREDITATIONS AND LISTINGS ................................................................................. 5 3.3 MEASUREMENT UNCERTAINTY ............................................................................................................... 5 4 GENERAL DESCRIPTION OF EUT .................................................................................................................. 6 5 DESCRIPTION OF TEST MODES ..................................................................................................................... 8 6 SETUP OF EQUIPMENT UNDER TEST ........................................................................................................... 9 6.1 BLOCK DIAGRAM CONFIGURATION OF TEST SYSTEM ....................................................................... 9 6.2 SUPPORT EQUIPMENT............................................................................................................................... 10 6.3 EQUIPMENTS LIST FOR ALL TEST ITEMS .............................................................................................. 11 7 TEST REQUIREMENTS .................................................................................................................................... 13 7.1 CONDUCTED EMISSIONS TEST ............................................................................................................... 13 7.2 RADIATED SPURIOUS EMISSION ............................................................................................................ 16 7.3 6DB BANDWIDTH ....................................................................................................................................... 25 7.4 DUTY CYCLE ............................................................................................................................................... 26 7.5 PEAK OUTPUT POWER .............................................................................................................................. 28 7.6 POWER SPECTRAL DENSITY ................................................................................................................... 29 7.7 CONDUCTED BAND EDGE MEASUREMENT......................................................................................... 31 7.8 SPURIOUS RF CONDUCTED EMISSIONS................................................................................................ 32 7.9 ANTENNA APPLICATION .......................................................................................................................... 33 8 TEST RESULTS ................................................................................................................................................... 34 8.1 1M .................................................................................................................................................................. 34 8.2 2M .................................................................................................................................................................. 47 Report No.: S22122300809001 Version.1.3 Page 3 of 61 1 TEST RESULT CERTIFICATION Applicant’s name ......................... : Wuhan Qiwu Technology Co., Ltd. Address ....................................... : 3 / F, Creative workshop, No.04, District D, Creative world, No.16 Yezhihu West Road, Hongshan District, Wuhan City, Hubei Province, China. Manufacturer's Name .................. : Wuhan Qiwu Technology Co., Ltd. Address ....................................... : 3 / F, Creative workshop, No.04, District D, Creative world, No.16 Yezhihu West Road, Hongshan District, Wuhan City, Hubei Province, China. Product description Product name .............................. : Heart Rate Trade Mark .................................. : iGPSPORT Model and/or type reference ..... : HR70 Family Model ............................... : HR70S, HR70P, HR70C, HR70 PLUS, HR70 PRO Measurement Procedure Used: APPLICABLE STANDARDS APPLICABLE STANDARD/ TEST PROCEDURE TEST RESULT FCC 47 CFR Part 2, Subpart J FCC 47 CFR Part 15, Subpart C KDB 174176 D01 Line Conducted FAQ v01r01 ANSI C63.10-2013 KDB 558074 D01 15.247 Meas Guidance v05r02 Complied This device described above has been tested by Shenzhen NTEK Testing Technology Co., Ltd., and the test results show that the equipment under test (EUT) is in compliance with the FCC requirements. And it is applicable only to the tested sample identified in the report. This report shall not be reproduced except in full, without the written approval of Shenzhen NTEK Testing Technology Co., Ltd.…

Text truncated - open the document above for the full version.

Test Report

Report No.: S22122300809002 Version.1.3 Page 1 of 47 RADIO TEST REPORT FCC ID: 2AU4M-HR70 Product: Heart Rate Trade Mark: iGPSPORT Model No.: HR70 Family Model: HR70S, HR70P, HR70C, HR70 PLUS, HR70 PRO Report No.: S22122300809002 Issue Date: Feb 02,2023 Prepared for Wuhan Qiwu Technology Co., Ltd. 3 / F, Creative workshop, No.04, District D, Creative world, No.16 Yezhihu West Road, Hongshan District, Wuhan City, Hubei Province, China. Prepared by Shenzhen NTEK Testing Technology Co., Ltd. 1/F, Building E, Fenda Science Park, Sanwei Community, Xixiang Street Bao’an District, Shenzhen 518126 P.R. China Tel:400-800-6106,0755-2320 0050 / 2320 0090 Website: http://www.ntek.org.cn Report No.: S22122300809002 Version.1.3 Page 2 of 47 TABLE OF CONTENTS 1 TEST RESULT CERTIFICATION ...................................................................................................................... 3 2 SUMMARY OF TEST RESULTS ......................................................................................................................... 4 3 FACILITIES AND ACCREDITATIONS ............................................................................................................. 5 3.1 FACILITIES..................................................................................................................................................... 5 3.2 LABORATORY ACCREDITATIONS AND LISTINGS ................................................................................. 5 3.3 MEASUREMENT UNCERTAINTY ............................................................................................................... 5 4 GENERAL DESCRIPTION OF EUT .................................................................................................................. 6 5 DESCRIPTION OF TEST MODES ..................................................................................................................... 8 6 SETUP OF EQUIPMENT UNDER TEST ........................................................................................................... 9 6.1 BLOCK DIAGRAM CONFIGURATION OF TEST SYSTEM ....................................................................... 9 6.2 SUPPORT EQUIPMENT............................................................................................................................... 10 6.3 EQUIPMENTS LIST FOR ALL TEST ITEMS .............................................................................................. 11 7 TEST REQUIREMENTS .................................................................................................................................... 13 7.1 CONDUCTED EMISSIONS TEST ............................................................................................................... 13 7.2 RADIATED SPURIOUS EMISSION ............................................................................................................ 16 7.3 6DB BANDWIDTH ....................................................................................................................................... 25 7.4 DUTY CYCLE ............................................................................................................................................... 26 7.5 PEAK OUTPUT POWER .............................................................................................................................. 28 7.6 POWER SPECTRAL DENSITY ................................................................................................................... 29 7.7 CONDUCTED BAND EDGE MEASUREMENT......................................................................................... 31 7.8 SPURIOUS RF CONDUCTED EMISSIONS................................................................................................ 32 7.9 ANTENNA APPLICATION .......................................................................................................................... 33 8 TEST RESULTS ................................................................................................................................................... 34 8.1 1M .................................................................................................................................................................. 34 8.2 2M .................................................................................................................................................................. 41 Report No.: S22122300809002 Version.1.3 Page 3 of 47 1 TEST RESULT CERTIFICATION Applicant’s name ......................... : Wuhan Qiwu Technology Co., Ltd. Address ....................................... : 3 / F, Creative workshop, No.04, District D, Creative world, No.16 Yezhihu West Road, Hongshan District, Wuhan City, Hubei Province, China. Manufacturer's Name .................. : Wuhan Qiwu Technology Co., Ltd. Address ....................................... : 3 / F, Creative workshop, No.04, District D, Creative world, No.16 Yezhihu West Road, Hongshan District, Wuhan City, Hubei Province, China. Product description Product name .............................. : Heart Rate Trade Mark .................................. : iGPSPORT Model and/or type reference ..... : HR70 Family Model ............................... : HR70S, HR70P, HR70C, HR70 PLUS, HR70 PRO Measurement Procedure Used: APPLICABLE STANDARDS APPLICABLE STANDARD/ TEST PROCEDURE TEST RESULT FCC 47 CFR Part 2, Subpart J FCC 47 CFR Part 15, Subpart C KDB 174176 D01 Line Conducted FAQ v01r01 ANSI C63.10-2013 KDB 558074 D01 15.247 Meas Guidance v05r02 Complied This device described above has been tested by Shenzhen NTEK Testing Technology Co., Ltd., and the test results show that the equipment under test (EUT) is in compliance with the FCC requirements. And it is applicable only to the tested sample identified in the report. This report shall not be reproduced except in full, without the written approval of Shenzhen NTEK Testing Technology Co., Ltd.…

Text truncated - open the document above for the full version.

Test Setup Photos

FCC ID: 2AU4M-HR70 Radiated Measurement Photos FCC ID: 2AU4M-HR70 Conducted Measurement Photos

Contact Information

Applicant

cai Li
[email protected]027-87835568Fax: 027-87835568

Test Firm

Shenzhen NTEK Testing Technology Co., Ltd.Alex Li
[email protected]+86-755-6115-9384

Technical Specifications

#Rule PartsFrequency RangePower Output
215C2.46 GHz - 2.46 GHz590.00 µW
Confidentiality
Long Term
Grant Notes
Power Listed is Conducted.

Other Applications from Wuhan Qiwu Technology Co., Ltd.

2AU4M-QW-WR02

GPS Sport Watch

Dec 18, 2025

Equipment Class

DTS - Digital Transmission System
HEART RATE MONITOR - FCC ID 2AU4M-HR50 - Wuhan Qiwu Technology Co., Ltd.
2AU4M-HR50

HEART RATE MONITOR

Apr 01, 2025

Equipment Class

DTS - Digital Transmission System
2AU4M-BSC300T

SMART BIKE COMPUTER

Sep 28, 2024

Equipment Class

DTS - Digital Transmission System
2AU4M-IGS800

GPS BIKE COMPUTER

Apr 14, 2024

Equipment Class

DTS - Digital Transmission System
iGPSPORT VS1200 Smart Frontlight - FCC ID 2AU4M-VS1200 - Wuhan Qiwu Technology Co., Ltd.
2AU4M-VS1200

iGPSPORT VS1200 Smart Frontlight

Feb 19, 2024

Equipment Class

DTS - Digital Transmission System