2AU7E-T201Temperature & Humidity Smart Sensor with Bluetooth

ShenZhen Sigmawit Technology Co.,Ltd
Temperature & Humidity Smart Sensor with Bluetooth - FCC ID 2AU7E-T201 - ShenZhen Sigmawit Technology Co.,Ltd
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Jun 22, 2020
Application Purpose
Original Equipment
Date of Application
Jun 21, 2020
Equipment Note
Temperature & Humidity Smart Sensor with Bluetooth
Frequency Range
2402.00000000 - 2480.00000000
Company
ShenZhen Sigmawit Technology Co.,Ltd
Country
China

Documents & Files

Select a file to view

Users Manual

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

External Photos

Reference N Waltek Tes http://www EXHIBI EUT View 1 EUT View 2 No.: WTX20X sting Group w.semtest.co T 2 - EUT 1 2 X06034935W (Shenzhen) m.cn T EXTER W-1 Co., Ltd. RNAL PH HOTOGR APHS Reference N Waltek Tes http://www EUT View 3 EUT View 4 No.: WTX20X sting Group w.semtest.co 3 4 X06034935W (Shenzhen) m.cn W-1 Co., Ltd. Reference N Waltek Tes http://www EUT View 5 EUT View 6 No.: WTX20X sting Group w.semtest.co 5 6 X06034935W (Shenzhen) m.cn W-1 Co., Ltd.

ID Label/Location Info

Reference N Waltek Tes http://www EXHIBI Proposed Specificatio n it is visible durable to r expected lif e Proposed No.: WTX20X sting Group w.semtest.co T 1 - PRO FCC ID La ns: The label or easily acc emain fully l etime. Label Loca X06034935W (Shenzhen) m.cn ODUCT L abel Forma shall be secu cessible to th legible and in ation on EU W-1 Co., Ltd. LABELIN at FCC ID urely affixed t he user, and ntact on the UT FCC NG D: 2AU7E-T to a permane shall not be device in al l ID Label Lo T201 ently attached readily detac l normal cond cation d part of the d chable. The l ditions of use device, in a lo label shall be e throughout ocation where e sufficiently t the device’s e y s

Internal Photos

Reference N Waltek Tes http://www EXHIBI EUT Housi n EUT Housi n No.: WTX20X sting Group w.semtest.co T 3 - EUT ng and Boar ng and Boar X06034935W (Shenzhen) m.cn T INTER rd View 1 rd View 1 W-1 Co., Ltd. NAL PHO OTOGRA APHS Reference N Waltek Tes http://www Solder Boa r Solder Boa r No.: WTX20X sting Group w.semtest.co rd-Compone rd-Compone X06034935W (Shenzhen) m.cn ent View 1 ent View 2 W-1 Co., Ltd. BLE Antenn na Reference N Waltek Tes http://www Solder Boa r Solder Boa r No.: WTX20X sting Group w.semtest.co rd-Compone rd-Compone X06034935W (Shenzhen) m.cn ent View 3 ent View 4 W-1 Co., Ltd. Reference N Waltek Tes http://www Solder Boa r No.: WTX20X sting Group w.semtest.co rd-Compone X06034935W (Shenzhen) m.cn ent View 5 W-1 Co., Ltd.

RF Exposure Info

1. MAXIMUM PERMISSIBLE EXPOSURE (MPE) 1.1 General Information Client Information Applicant: ShenZhen SigmaWit Technology Co.,Ltd Address of applicant: 11th floor,Lingyun Building, DingXin Industrial Area, Honglang North 2nd Road, Bao'an, ShenZhen,Guangdong Province,China Manufacturer: ShenZhen SigmaWit Technology Co.,Ltd Address of manufacturer: 11th floor,Lingyun Building, DingXin Industrial Area, Honglang North 2nd Road, Bao'an, ShenZhen,Guangdong Province,China General Description of EUT: Product Name: Temperature & Humidity Smart Sensor Brand Name: / Model No.: T201 Adding Model(s): / FCC ID: 2AU7E-T201 Rated Voltage: Battery: DC3V Technical Characteristics of EUT: Bluetooth Version: V5.0 (BLE mode) Frequency Range: 2402-2480MHz RF Output Power: 0.93dBm (Conducted) Data Rate: 1Mbps Modulation: GFSK Quantity of Channels: 40 Channel Separation: 2MHz Type of Antenna: PCB Antenna Antenna Gain: 0dBi 1.2 Standard Applicable According to §1.1307(b)(1) and KDB 447498 D01 General RF Exposure Guidance v06, system operating under the provisions of this section shall be operating in a manner that the public is not exposed to radio frequency energy level in excess limit for maximum permissible exposure. (a) Limits for Occupational / Controlled Exposure Frequency range (MHz) Electric Field Strength (E) (V/m) Magnetic Field Strength (H) (A/m) Power Density (S) (mW/cm 2 ) Averaging Times | E | 2 , | H | 2 or S (minutes) 0.3-3.0 614 1.63 (100)* 6 3.0-30 1842/f 4.89/f (900/f)* 6 30-300 61.4 0.163 1.0 6 300-1500 / / F/300 6 1500-100000 / / 5 6 (b) Limits for General Population / Uncontrolled Exposure Frequency range (MHz) Electric Field Strength (E) (V/m) Magnetic Field Strength (H) (A/m) Power Density (S) (mW/cm 2 ) Averaging Times | E | 2 , | H | 2 or S (minutes) 0.3-1.34 614 1.63 (100)* 30 1.34-30 824/f 2.19/f (180/f)* 30 30-300 27.5 0.073 0.2 30 300-1500 / / F/1500 30 1500-100000 / / 1 30 Note: f = frequency in MHz: * = Plane-wave equivalents power density 1.3 MPE Calculation Method S = (30*P*G) / (377*R 2 ) S = power density (in appropriate units, e.g., mw/cm 2 ) P = power input to the antenna (in appropriate units, e.g., mw) G = power gain of the antenna in the direction of interest relative to an isotropic radiator, the power gain factor is normally numeric gain. R = distance to the center of radiation of the antenna (in appropriate units, e.g., cm) 1.4 MPE Calculation Result Maximum Tune-Up output power: 1 (dBm) Maximum peak output power at antenna input terminal: 1.26(mW) Prediction distance: >20(cm) Prediction frequency: 2402 (MHz) Antenna gain: 0(dBi) Directional gain (numeric gain): 1 The worst case is power density at prediction frequency at 20cm: 0.0003(mw/cm 2 ) MPE limit for general population exposure at prediction frequency: 1 (mw/cm 2 ) Result: Pass

Test Report

Waltek Testing Group (Shenzhen) Co., Ltd. http://www.semtest.com.cn Page 1 of 35 TEST REPORT Reference No. .................... : WTX20X06034935W-1 FCC ID ................................ : 2AU7E-T201 Applicant ........................... : ShenZhen SigmaWit Technology Co.,Ltd Address ............................. : 11th floor,Lingyun Building, DingXin Industrial Area, Honglang North 2nd Road, Bao'an, ShenZhen,Guangdong Province,China Manufacturer ................... : ShenZhen SigmaWit Technology Co.,Ltd Address ............................. : 11th floor,Lingyun Building, DingXin Industrial Area, Honglang North 2nd Road, Bao'an, ShenZhen,Guangdong Province,China Product Name ................... : Temperature & Humidity Smart Sensor Test Model. ........................ : T201 Standards .......................... : FCC Part 15.247 Date of Receipt sample .... : Jun.08, 2020 Date of Test........................ : Jun.08, 2020 to Jun.10, 2020 Date of Issue ..................... : Jun.10, 2020 Test Result ......................... : Pass Remarks: The results shown in this test report refer only to the sample(s) tested, this test report cannot be reproduced, except in full, without prior written permission of the company. The report would be invalid without specific stamp of test institute and the signatures of compiler and approver. Prepared By: Waltek Testing Group (Shenzhen) Co., Ltd. Address: 1/F., Room 101, Building 1, Hongwei Industrial Park, Liuxian 2nd Road, Block 70 Bao'an District, Shenzhen, Guangdong, China Tel.: +86-755-33663308 Fax.: +86-755-33663309 Tested by: Reviewed By: Approved & Authorized By: Mike Shi / Project Engineer Lion Cai / RF Manager Silin Chen / Manager Reference No.: WTX20X06034935W-1 Page 2 of 35 Waltek Testing Group (Shenzhen) Co., Ltd. http://www.semtest.com.cn TABLE OF CONTENTS 1. GENERAL INFORMATION ................................................................................................................................... 4 1.1 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT) ............................................................................... 4 1.2 TEST STANDARDS ................................................................................................................................................... 5 1.3 TEST METHODOLOGY ............................................................................................................................................. 5 1.4 TEST FACILITY ....................................................................................................................................................... 5 1.5 EUT SETUP AND TEST MODE ................................................................................................................................. 6 1.6 MEASUREMENT UNCERTAINTY .............................................................................................................................. 6 1.7 TEST EQUIPMENT LIST AND DETAILS ..................................................................................................................... 7 2. SUMMARY OF TEST RESULTS ........................................................................................................................... 9 3. RF EXPOSURE ....................................................................................................................................................... 10 3.1 STANDARD APPLICABLE ....................................................................................................................................... 10 3.2 TEST RESULT........................................................................................................................................................ 10 4. ANTENNA REQUIREMENT ................................................................................................................................ 11 4.1 STANDARD APPLICABLE ....................................................................................................................................... 11 4.2 EVALUATION INFORMATION ................................................................................................................................ 11 5. POWER SPECTRAL DENSITY ........................................................................................................................... 12 5.1 STANDARD APPLICABLE ....................................................................................................................................... 12 5.2 TEST SETUP BLOCK DIAGRAM ............................................................................................................................. 12 5.3 TEST PROCEDURE ................................................................................................................................................. 12 5.4 SUMMARY OF TEST RESULTS/PLOTS .................................................................................................................... 12 6. DTS BANDWIDTH ................................................................................................................................................. 14 6.1 STANDARD APPLICABLE ....................................................................................................................................... 14 6.2 TEST SETUP BLOCK DIAGRAM ............................................................................................................................. 14 6.3 TEST PROCEDURE ................................................................................................................................................. 14 6.4 SUMMARY OF TEST RESULTS/PLOTS .................................................................................................................... 14 7. RF OUTPUT POWER ....................................................................................................................................…

Text truncated - open the document above for the full version.

Test Setup Photos

Reference N Waltek Tes http://www EXHIBI Radiation E Radiation E No.: WTX20X sting Group w.semtest.co T 4 - TES Emission Tes Emission Tes X06034935W (Shenzhen) m.cn ST SETUP st Setup (Belo st Setup (30M W-1 Co., Ltd. P PHOTO ow 30MHz) MHz to 1GHz OGRAPH z) HS Reference N Waltek Tes http://www Radiation E Radiation E No.: WTX20X sting Group w.semtest.co Emission Tes Emission Tes X06034935W (Shenzhen) m.cn st Setup (1GH st Setup (Abo W-1 Co., Ltd. Hz to 18GHz ove 18GHz) z) \ Reference N Waltek Tes http://www No.: WTX20X sting Group w.semtest.co X06034935W (Shenzhen) m.cn W-1 Co., Ltd.

Contact Information

Applicant

Lianggang Li
[email protected]86-13480701202Fax: 86-755-33683385

Test Firm

Waltek Testing Group (Shenzhen) Co., Ltd.Jandy So
[email protected]86 755 33663308Fax: 86-755-33663309

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz1.00 mW
Confidentiality
Long Term
Grant Notes
Output power listed is peak conducted.

Other Applications from ShenZhen Sigmawit Technology Co.,Ltd

SMART FINDER - FCC ID 2AU7E-FD620 - ShenZhen Sigmawit Technology Co.,Ltd
2AU7E-FD620

SMART FINDER

Jan 13, 2021

Equipment Class

DTS - Digital Transmission System
Temperature & Humidity Smart Sensor - FCC ID 2AU7E-T301 - ShenZhen Sigmawit Technology Co.,Ltd
2AU7E-T301

Temperature & Humidity Smart Sensor

Dec 28, 2020

Equipment Class

DTS - Digital Transmission System