  1. Home/
  2. THINKCAR TECH CO., LTD./
  3. 2AUARTHINKTOOL

2AUARTHINKTOOLTHINKTOOL PROS+, THINKTOOL PROS, THINKTOOL PRO, ThinkTool Master X, ThinkTool Master, ThinkTool Platinum S10, ThinkTool Platinum S8, Phoenix Plus, CR Ultra, THINKTOOL Platinum HD, THINKTOOL Platinum J2534

THINKCAR TECH CO., LTD.
THINKTOOL PROS+, THINKTOOL PROS, THINKTOOL PRO, ThinkTool Master X, ThinkTool Master, ThinkTool Platinum S10, ThinkTool Platinum S8, Phoenix Plus, CR Ultra, THINKTOOL Platinum HD, THINKTOOL Platinum J2534 - FCC ID 2AUARTHINKTOOL - THINKCAR TECH CO., LTD.
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Feb 24, 2021
Application Purpose
Original Equipment
Date of Application
Feb 24, 2021
Equipment Note
THINKTOOL PROS+, THINKTOOL PROS, THINKTOOL PRO, ThinkTool Master X, ThinkTool Master, ThinkTool Platinum S10, ThinkTool Platinum S8, Phoenix Plus, CR Ultra, THINKTOOL Platinum HD, THINKTOOL Platinum J2534
Frequency Range
2412.00000000 - 2462.00000000
Company
THINKCAR TECH CO., LTD.
Country
China

Documents & Files

Select a file to view

Users Manual

↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Operational Description

↗

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Version: V1.00.001 Statement: THINKCAR owns the complete intellectual property rights for the software used by this product. For any reverse engineering or cracking actions against the software, THINKCAR will block the use of this product and reserve the right to pursue their legal liabilities. THINKCAR www.mythinkcar.com THINKTOOL Pros+/Pros I IC Requirement This device contains licence-exempt transmitter(s)/receiver(s) that comply with Innovation,Science and Economic Development Canada’ s licence-exempt RSS(s). Operation is subject to the following two conditions: (1)This device may not cause interference. (2)This device must accept any interference,including interference that may cause undesired operation of the device. L'émetteur/récepteur exempt de licence contenu dans le présent appareil est conforme aux CNR d'Innovation,Sciences et Développement économique Canada applicables aux appareils radio exempts de licence. L 'exploitation est autorisée aux deux conditions suivantes : 1)L'appareil ne doit pas produire de brouillage; 2)L'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement. IC WARNING Cet équipement est conforme aux limites d’exposition aux rayonnements ISED établies pour un HQYLURQQHPHQWQRQFRQWU{Op/¶XWLOLVDWHXU¿QDOGRLWVXLYUHOHV LQVWUXFWLRQVVSpFL¿TXHVSRXUVDWLVIDLUHOHV normes. Cet émetteur ne doit pas être co-implanté ou fonctionner en conjonction avec toute autre antenne ou transmetteur. Le dispositif por tatif est conçu pour répondre aux exigences d’exposition aux ondes radio établie par ledéveloppement énergétique DURABLE. Ces exigences un SAR limite de 1,6 W/kg en moyenne pour un gramme de tissu. FHUWL¿FDWLRQGHSURGXLWjXWLOLVHUORUVTX¶LOHVWFRUUHFWHPHQWSRUWpVXUOHFRUSV www.mythinkcar.com THINKTOOL Pros+/Pro II FCC Requirement &KDQJHVRUPRGL¿FDWLRQVQRWH[SUHVVO\DSSURYHGE\WKHSDUW\UHVSRQVLEOHIRUFRPSOLDQFHFRXOGYRLGWKH user’ s authority to operate the equipment. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy, and if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio RUWHOHYLVLRQUHFHSWLRQZKLFKFDQEHGHWHUPLQHGE\WXUQLQJWKHHTXLSPHQWRႇDQGRQWKHXVHULV encouraged to try to correct the interference by one or more of the following measures: – Reorient or relocate the receiving antenna. – Increase the separation between the equipment and receiver. ±&RQQHFWWKHHTXLSPHQWLQWRDQRXWOHWRQDFLUFXLWGLႇHUHQWIURPWKDWWRZKLFKWKHUHFHLYHULVFRQQHFWHG – Consult the dealer or an experienced radio/TV technician for help. FCC WARNING This equipment c omplies with FCC radiation exposure limits set forth for an uncontrolled environment. End XVHUPXVWIROORZWKHVSHFL¿FRSHUDWLQJLQVWUXFWLRQVIRUVDWLVI\LQJ5)H[SRVXUHFRPSOLDQFH7KLVWUDQVPLWWHU must not be co-located or operating in conjunction with any other antenna or transmitter. The mobile dev ice is designed to meet the requirements for exposure to radio waves established by the Federal Communications Commission (USA). These requirements set a SAR limit of 1.6 W/kg averaged RYHURQHJUDPRIWLVVXH For body operation, this device has been tested and meets FCC RF exposure guidelines when used with any accessory that contains no metal and that positions a minimum of 15mm from the body. Use of other accessories may not ensure compliance with FCC RF exposure guidelines. www.mythinkcar.com THINKTOOL Pros+/Pros III Copyright Information Copyright © 2020 by THINKCAR TECH CO., LTD(hereinafter referred to as “THINKCAR”). All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form or by any means, electronic, mechanical, photocopying and recording or otherwise, without the prior written permission of THINKCAR. The information contained herein is designed only for the use of this unit. THINKCAR is not responsible for any use of this information as applied to other units. 1HLWKHU7+,1.&$5QRULWVDႈOLDWHVVKDOOEHOLDEOHWRWKHSXUFKDVHURIWKLVXQLWRUWKLUGSDUWLHVIRUGDPDJHV losses, costs, or expenses incurred by purchaser or third parties as a result of: Accident, misuse, or abuse RIWKLVXQLWRUXQDXWKRUL]HGPRGL¿FDWLRQVUHSDLUVRUDOWHUDWLRQVWRWKLVXQLWRUIDLOXUHWRVWULFWO\FRPSO\ZLWK THINKCAR operating and maintenance instructions. THINKCAR shall not be liable for any damages or problems arising from the use of any options or any consumable products other than those designated as Original THINKCAR Products or THINKCAR Approved Products. Formal statement: The names of other products mentioned in this manual are intended to explain how to use this equipment, and the registered trademark ownership still belongs to the original company. This equipment is designed for professional technicians or maintenance personnel. Trademark THINKCAR is a registered trademark of THINKCAR TECH CO., LTD in China and other overseas countries. All other THINKCAR trademarks, service marks, domain names, logos, and company names referred to in this manual are either trademarks, registered trademarks, service marks, domain names, ORJRVFRPSDQ\QDPHVRIRUDUHRWKHUZLVHWKHSURSHUW\…

Text truncated - open the document above for the full version.

External Photos

FCC ID: 2AUARTHINKTOOL FCC ID: 2AUARTHINKTOOL FCC ID: 2AUARTHINKTOOL FCC ID: 2AUARTHINKTOOL FCC ID: 2AUARTHINKTOOL

ID Label/Location Info

Label location

Internal Photos

FCC ID: 2AUARTHINKTOOL FCC ID: 2AUARTHINKTOOL FCC ID: 2AUARTHINKTOOL FCC ID: 2AUARTHINKTOOL

Operational Description

version01 THINKCAR TECH CO., LTD. Declaration concerning Antenna Specification It is hereby declared that the product Model No.: TKT04, TKT05, TKT03, Phoenix Plus, CR Ultra FCC ID: 2AUARTHINKTOOL fulfills the requirement in FCC test relating to the antenna type. The device specified above confirms to the FCC recommendations for internal / external antenna type(s) described below: Model No. of antenna: N/A Type of antenna: internal antenna with ipex connector Gain of the antenna: 1.61 dBi Frequency range: 2400MHz~2483.5MHz Model No. of antenna: N/A Type of antenna: internal antenna with ipex connector Gain of the antenna: 3.68 dBi Frequency range: 5150MHz~5250MHz Model No. of antenna: N/A Type of antenna: internal antenna with ipex connector Gain of the antenna: 5.46 dBi Frequency range: 5725MHz~5850MHz The mounting of the antenna is fixed to the radio module and no other antenna should be used. Company name: THINKCAR TECH CO., LTD. Address: 2606, building 4, phase II, TiananYungu, Gangtou community, Bantian, Longgang District City: Shenzhen ZIP / Postal code: / Country: China Place: Bantian, Longgang District Date: 2021-2-3 Signature:

RF Exposure Info

ReportNo.:WT208003180Page1of85 SARTESTREPORT For THINKTOOLPROS+、THINKTOOLPROS、THINKTOOLPRO、 ThinkToolMasterX、ThinkToolMaster、ThinkToolPlatinumS10、 ThinkToolPlatinumS8、PhoenixPlus、CRUltra、THINKTOOL PlatinumHD、THINKTOOLPlatinumJ2534 FCCID:2AUARTHINKTOOL IC:26415-THINKTOOL ReportNumber:WT208003180 TestLaboratory:ShenzhenAcademyofMetrologyandQuality Inspection NationalDigitalElectronicProductTestingCenter SiteLocation:NETCBuilding,No.4TongfaRoad,XiliTown, NanshanDistrict,Shenzhen,Guangdong,China Tel:0086-755-86928965 Fax:0086-755-86009898-31396 Web:www.smq.com.cn Email:[email protected] ReportNo.:WT208003180Page2of85 Testreportdeclaration Applicant:THINKCARTECHCO.,LTD. Address: 2606,building4,phaseII,TiananYungu,Gangtoucommunity,Bantian, LonggangDistrict,Shenzhen Manufacturer:THINKCARTECHCO.,LTD.BanTianBranch Address : 2606,building4,phaseII,TiananYungu,Gangtoucommunity,Bantian, LonggangDistrict,Shenzhen EUTDescription: THINKTOOLPROS+、THINKTOOLPROS、THINKTOOLPRO、 ThinkToolMasterX、ThinkToolMaster、ThinkToolPlatinumS10、 ThinkToolPlatinumS8、PhoenixPlus、CRUltra、THINKTOOL PlatinumHD、THINKTOOLPlatinumJ2534 ModelNo.: TKT04、TKT05、TKT03、PhoenixPlus、CRUltra Brand:THINKCAR FCCID:2AUARTHINKTOOL IC:26415-THINKTOOL TestStandards: IEEEStd1528-2013,KDB941225D06,KDB447498D01,KDB865664D01,KDB865664 D02,KDB690783D01,RSS-102 TheEUTdescribedaboveistestedbyShenzhenAcademyofMetrologyandQualityInspection EMCLaboratorytodeterminethecomplianceoftheapplicablestandardsstatedabove. ShenzhenAcademyofMetrologyandQualityInspectionEMCLaboratoryisassumedfull responsibilityfortheaccuracyofthetestresults. Theresultsdocumentedinthisreportonlyapplytothetestedsample,undertheconditionsand modesofoperationasdescribedherein. Thetestreportshallnotbereproducedinpartwithoutwrittenapprovalofthelaboratory. ProjectEngineer: Date: Dec25,2020 (ZhangQiang) Checkedby: Date: Dec25,2020 (LinYixiang) Approvedby: Date: Dec25,2020 (LinBin) ReportNo.:WT208003180Page3of85 TABLEOFCONTENTS 1.REPORTEDSARSUMMARY...........................................................................................................5 1.1.StatementofCompliance.......................................................................................................5 1.2.RFexposurelimits(ICNIRPGuidelines) ..............................................................................6 1.3RatingsandSystemDetails ....................................................................................................7 1.4ProductFunctionandIntendedUse ......................................................................................7 1.5Testspecification(s)..................................................................................................................8 1.6ListofTestandMeasurementInstruments..........................................................................9 2.GENERALINFORMATION.................................................................................................................10 2.1.Reportinformation .................................................................................................................10 2.2.LaboratoryAccreditationandRelationshiptoCustomer.................................................10 3.SARMEASUREMENTSYSTEMCONFIGURATION....................................................................11 3.1.SARMeasurementSet-up...................................................................................................11 3.2.Probedescription...................................................................................................................12 3.3.Deviceholderdescription.....................................................................................................14 4.SARMEASUREMENTPROCEDURE..............................................................................................14 4.1.Scanningprocedure..............................................................................................................14 7.SYSTEMVERIFICATIONPROCEDURE.........................................................................................20 7.1.TissueVerification .................................................................................................................20 8.SARMEASUREMENTVARIABILITYANDUNCERTAINTY........................................................23 8.1.SARmeasurementvariability ..............................................................................................23 8.2.SARmeasurementuncertainty............................................................................................23 9.TestConfiguration ................................................................................................................................24 10.TUNE-UPLIMIT ..................................................................................................................................25 11.MEASUREMENTRESULTS ............................................................................................................25 11.1.ConductedPower................................................................................................................25 11.2.2.4GSARresults .................................................................................................................30 11.3.5.2GSARresults.................................................................................................................30 11.4.5.8GSARresults.................................................................................................................31 11.5.BTSARresults....................................................................................................................31 11.6.RepeatedSARresults ........................................................................................................31 11.7.SimultaneousTransmissionPossibilities .........................................................................32 ReportNo.:WT208003180Page4of85 11.8.SARSummationScenario …

Text truncated - open the document above for the full version.

Test Report

Shenzhen Huaxia Testing Technology Co., Ltd 1F., Block A of Tongsheng Technology Building, Huahui Road, Dalang Street, Longhua District, Shenzhen, China Telephone: +86-755-26648640 Fax: +86-755-26648637 Website: www.cqa-cert.com Report Template Version: V04 Report Template Revision Date: 2018-07-06 Test Report The test report is effective only with both signature and specialized stamp, The result(s) shown in this report refer only to the sample(s) tested. Without written approval of CQA, this report can’t be reproduced except in full. Report No.: CQASZ20201101374E-01 Applicant: THINKCAR TECH CO., LTD. Address of Applicant: 2606, building 4, phase II, TiananYungu, Gangtou community, Bantian, Longgang District, Shenzhen Equipment Under Test (EUT): Product: THINKTOOL PROS+, THINKTOOL PROS, THINKTOOL PRO, ThinkTool Master X, ThinkTool Master, ThinkTool Platinum S10, ThinkTool Platinum S8, Phoenix Plus, CR Ultra, THINKTOOL Platinum HD, THINKTOOL Platinum J2534 Model No.: TKT04, TKT05, TKT03, Phoenix Plus, CR Ultra Teat Model No.: TKT04 Brand Name: THINKCAR FCC ID: 2AUARTHINKTOOL Standards: 47 CFR Part 15, Subpart C Date of Receipt: 2020-11-19 Date of Test: 2020-11-19 to 2020-12-16 Date of Issue: 2020-12-16 Test Result : PASS* *In the configuration tested, the EUT complied with the standards specified above Tested By: ( Martin Lee ) Reviewed By: ( Ares Liu ) Approved By: ( Sheek Luo ) Shenzhen Huaxia Testing Technology Co., Ltd Report No.: CQASZ20201101374E-01 Page:2 of 59 1 Version Revision History Of Report Report No. Version Description Issue Date CQASZ20201101374E-01 Rev.01 Initial report 2020-12-16 Shenzhen Huaxia Testing Technology Co., Ltd Report No.: CQASZ20201101374E-01 Page:3 of 59 2 Test Summary Test Item Test Requirement Test method Result Antenna Requirement 47 CFR Part 15, Subpart C Section 15.203/15.247 (c) ANSI C63.10 2013 PASS AC Power Line Conducted Emission 47 CFR Part 15, Subpart C Section 15.207 ANSI C63.10 2013 PASS Conducted Peak Output Power 47 CFR Part 15, Subpart C Section 15.247 (b)(3) ANSI C63.10 2013 PASS 6dB Occupied Bandwidth 47 CFR Part 15, Subpart C Section 15.247 (a)(2) ANSI C63.10 2013 PASS Power Spectral Density 47 CFR Part 15, Subpart C Section 15.247 (e) ANSI C63.10 2013 PASS Band-edge for RF Conducted Emissions 47 CFR Part 15, Subpart C Section 15.247(d) ANSI C63.10 2013 PASS RF Conducted Spurious Emissions 47 CFR Part 15, Subpart C Section 15.247(d) ANSI C63.10 2013 PASS Radiated Spurious Emissions 47 CFR Part 15, Subpart C Section 15.205/15.209 ANSI C63.10 2013 PASS Restricted bands around fundamental frequency (Radiated Emission) 47 CFR Part 15, Subpart C Section 15.205/15.209 ANSI C63.10 2013 PASS Shenzhen Huaxia Testing Technology Co., Ltd Report No.: CQASZ20201101374E-01 Page:4 of 59 3 Contents Page 1 VERSION .................................................................................................................................................................. 2 2 TEST SUMMARY .................................................................................................................................................... 3 3 CONTENTS .............................................................................................................................................................. 4 4 GENERAL INFORMATION ................................................................................................................................... 5 4.1 CLIENT INFORMATION .......................................................................................................................................... 5 4.2 GENERAL DESCRIPTION OF EUT .......................................................................................................................... 5 4.3 PRODUCT SPECIFICATION SUBJECTIVE TO THIS STANDARD .................................................................................. 5 4.4 ADDITIONAL INSTRUCTIONS................................................................................................................................. 7 4.5 TEST ENVIRONMENT ............................................................................................................................................ 8 4.6 DESCRIPTION OF SUPPORT UNITS ......................................................................................................................... 8 4.7 STATEMENT OF THE MEASUREMENT UNCERTAINTY ............................................................................................. 9 4.8 TEST LOCATION ................................................................................................................................................. 10 4.9 TEST FACILITY ................................................................................................................................................... 10 4.10 DEVIATION FROM STANDARDS ........................................................................................................................... 10 4.11 OTHER INFORMATION REQUESTED BY THE CUSTOMER ...................................................................................... 10 4.12 EQUIPMENT LIST ................................................................................................................................................ 11 5 TEST RESULTS AND MEASUREMENT DATA .............................................................................................. 12 5.1 ANTENNA REQUIREMENT ................................................................................................................................... 12 5.2 CONDUCTED EMISSIONS ..................................................................................................................................... 13 5.3 CONDUCTED PEAK OUTPUT POWER ................................................................................................................... 17 5.4 6DB OCCUPY BANDWIDTH .................................…

Text truncated - open the document above for the full version.

Test Report

Shenzhen Huaxia Testing Technology Co., Ltd 1F., Block A of Tongsheng Technology Building, Huahui Road, Dalang Street, Longhua District, Shenzhen, China Telephone: +86-755-26648640 Fax: +86-755-26648637 Website: www.cqa-cert.com Report Template Version: V04 Report Template Revision Date: 2018-07-06 TEST REPORT The test report is effective only with both signature and specialized stamp, The result(s) shown in this report refer only to the sample(s) tested. Without written approval of CQA, this report can’t be reproduced except in full. ii Report No.: CQASZ20201101374E-03 Applicant: THINKCAR TECH CO., LTD. Address of Applicant: 2606, building 4, phase II, TiananYungu, Gangtou community, Bantian, Longgang District, Shenzhen Equipment Under Test (EUT): Product: THINKTOOL PROS+, THINKTOOL PROS, THINKTOOL PRO, ThinkTool Master X, ThinkTool Master, ThinkTool Platinum S10, ThinkTool Platinum S8, Phoenix Plus, CR Ultra, THINKTOOL Platinum HD, THINKTOOL Platinum J2534 Model No.: TKT04, TKT05, TKT03, Phoenix Plus, CR Ultra Teat Model No.: TKT04 Brand Name: THINKCAR FCC ID: 2AUARTHINKTOOL Standards: 47 CFR Part 15, Subpart C Date of Receipt: 2020-11-19 Date of Test: 2020-11-19 to 2020-12-16 Date of Issue: 2020-12-16 Test Result : PASS* *In the configuration tested, the EUT complied with the standards specified above Tested By: ( Martin Lee ) Reviewed By: ( Ares Liu ) Approved By: ( Sheek Luo ) . Shenzhen Huaxia Testing Technology Co., Ltd Report No.: CQASZ20201101374E-03 Page:2 of 84 1 Version Revision History Of Report Report No. Version Description Issue Date CQASZ20201101374E-03 Rev.01 Initial report 2020-12-16 Shenzhen Huaxia Testing Technology Co., Ltd Report No.: CQASZ20201101374E-03 Page:3 of 84 2 Test Summary Test Item Test Requirement Test method Result Antenna Requirement 47 CFR Part 15, Subpart C Section 15.203/15.247 (c) ANSI C63.10 2013 PASS AC Power Line Conducted Emission 47 CFR Part 15, Subpart C Section 15.207 ANSI C63.10 2013 PASS Conducted Peak & Average Output Power 47 CFR Part 15, Subpart C Section 15.247 (b)(3) ANSI C63.10 2013 PASS 6dB Occupied Bandwidth 47 CFR Part 15, Subpart C Section 15.247 (a)(2) ANSI C63.10 2013 PASS Power Spectral Density 47 CFR Part 15, Subpart C Section 15.247 (e) ANSI C63.10 2013 PASS Band-edge for RF Conducted Emissions 47 CFR Part 15, Subpart C Section 15.247(d) ANSI C63.10 2013 PASS RF Conducted Spurious Emissions 47 CFR Part 15, Subpart C Section 15.247(d) ANSI C63.10 2013 PASS Radiated Spurious Emissions 47 CFR Part 15, Subpart C Section 15.205/15.209 ANSI C63.10 2013 PASS Restricted bands around fundamental frequency (Radiated Emission) 47 CFR Part 15, Subpart C Section 15.205/15.209 ANSI C63.10 2013 PASS Shenzhen Huaxia Testing Technology Co., Ltd Report No.: CQASZ20201101374E-03 Page:4 of 84 3 Contents Page 1 VERSION .............................................................................................................................................................. 2 2 TEST SUMMARY ................................................................................................................................................ 3 3 CONTENTS .......................................................................................................................................................... 4 4 GENERAL INFORMATION ............................................................................................................................... 5 4.1 CLIENT INFORMATION ................................................................................................................................... 5 4.2 GENERAL DESCRIPTION OF EUT ................................................................................................................. 5 4.3 GENERAL DESCRIPTION OF EUT ................................................................................................................. 5 4.4 TEST ENVIRONMENT AND MODE .................................................................................................................. 8 4.5 DESCRIPTION OF SUPPORT UNITS ............................................................................................................. 12 4.6 TEST LOCATION .......................................................................................................................................... 12 4.7 TEST FACILITY ............................................................................................................................................. 12 4.8 STATEMENT OF THE MEASUREMENT UNCERTAINTY ................................................................................... 13 4.9 DEVIATION FROM STANDARDS .................................................................................................................... 13 4.10 ABNORMALITIES FROM STANDARD CONDITIONS ........................................................................................ 13 4.11 OTHER INFORMATION REQUESTED BY THE CUSTOMER ............................................................................ 13 4.12 EQUIPMENT LIST ......................................................................................................................................... 14 5 TEST RESULTS AND MEASUREMENT DATA .......................................................................................... 15 5.1 ANTENNA REQUIREMENT ............................................................................................................................ 15 5.2 CONDUCTED EMISSIONS ............................................................................................................................. 16 5.3 CONDUCTED PEAK & AVERAGE OUTPUT POWER...................................................................................... 20 5.4 6DB OCCUPY BANDWIDTH .......................................................................................................................... 22 5.5 POWER SPECTRAL DENSITY ..........................…

Text truncated - open the document above for the full version.

Test Setup Photos

FCC ID: 2AUARTHINKTOOL 1 Photographs - EUT Test Setup 1.1 Radiated Spurious Emission 9kHz~30MHz: 30MHz~1GHz: FCC ID: 2AUARTHINKTOOL Above 1GHz: 1.2 Conducted Emission

Contact Information

Applicant

Jinyuan Tang(Manager)
[email protected]86-0755-23760920Fax: 86-0755-23760920

Test Firm

Shenzhen Huaxia Testing Technology Co., LtdJack Ai
[email protected]+8613902988375

Technical Specifications

#Rule PartsFrequency RangePower Output
215C2.41 GHz - 2.46 GHz61.60 mW
Confidentiality
Long Term
Grant Notes
Power listed is conducted. This device supports 20 and 40MHz bandwidth operation. SAR compliance is based on a separation distance of 0 mm between the unit and the body of the user. Belt clips or holsters not listed in this filing may not contain metallic components. Highest reported SAR for Body-worn and simultaneous transmission is: 0.733W/kg and 1.368W/kg (1g) respectively.

Other Applications from THINKCAR TECH CO., LTD.

Automotive Diagnostic Device - FCC ID 2AUARTKDIAG - THINKCAR TECH CO., LTD.
2AUARTKDIAG

Automotive Diagnostic Device

Sep 22, 2024

Equipment Class

DTS - Digital Transmission System
TPMS Intelligent Detection Tool - FCC ID 2AUARTK672 - THINKCAR TECH CO., LTD.
2AUARTK672

TPMS Intelligent Detection Tool

Aug 20, 2024

Equipment Class

DTS - Digital Transmission System
Automotive Diagnostic Device - FCC ID 2AUARTKMINI - THINKCAR TECH CO., LTD.
2AUARTKMINI

Automotive Diagnostic Device

Jul 21, 2024

Equipment Class

DTS - Digital Transmission System
Smart Diagnostic Tool - FCC ID 2AUARVENU90 - THINKCAR TECH CO., LTD.
2AUARVENU90

Smart Diagnostic Tool

Jul 13, 2024

Equipment Class

DCD - Part 15 Low Power Transmitter Below 1705 kHz
2AUARVENUIMINI

TPMS Intelligent Detection Tool

Jul 01, 2024

Equipment Class

DCD - Part 15 Low Power Transmitter Below 1705 kHz