Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
CAUTION: Risk of explosion if battery is replaced by an incorrect type. Dispose of used batteries according to the instructions. Do not replace battery with an incorrect type. Do not disposal battery into fire or a hot oven, or mechanically crushing or cutting of a battery, that can result in an explosion. Do not leaving battery in an extremely high temperature surrounding environment that can result in an explosion or the leakage of flammable liquid or gas. Do not leaving battery subjected to extremely ow air pressure that may result in an explosion or the leakage of flammable liquid or gas. Do not used in low air pressure at high altitude condition. Do not used in high or low extreme temperatures.
LocalRepresentativeLetter ForCertificationServiceintheUSA FederalCommunicationsCommission EquipmentAuthorizationDivision,ApplicationProcessingBranch 7435OaklandMillsRoad Columbia,MD21048 Towhomitmayconcern PursuanttoSection2.911(d)(7),oftheCommission’sRules(47C.F.R.)weattestasfollowsfor theproductlistedbelow: FCCIDModelname 2AUDZ-H01H01,H02,H03,H05,H06,H08,H09,H10, H12 Weherebyacknowledgeasfollows: i.bothsigneesconfirmthatthepointofcontactacceptsresponsibilitytoactasaUS- AmericanRepresentativeonbehalfoftheapplicant ii.thepointofcontactprovidesthephysicalU.S.addressandemailaslistedbelow iii.bothpartiesmaintaintherequirementsofthisagreementfornolessthanoneyear afterthegranteehasterminatedallmarketingandimportationortheconclusionof anyCommission-relatedproceedinginvolvingtheequipment. iv.Anexpirationdateforthisletterdoesnotexist.IncasetheU.S.agentchanges,the granteeisobligatedtonotifytheFCCwithin30daysviathegrantingTCB. US-AmericanPointofContactApplicant/ApprovalHolder SignatureDate:2026-9-16SignatureDate:2026-9-16 CompanyName:GLOCERTSTECHNOLOGYINCShenzhenKeithyInnovation TechnologyCo.,Ltd. FRN:00363397370028708394 ContactName:HuiyingFanChunxingZhou Address:19784SUNKISSEDRIDGEDR, RIVERSIDE,CA92507UnitedStates RM101,BuildingB,MiliCultural andCreativePark,No.6,Changfa EastRoad,YangmeiCommunity, BantianStreet,LonggangDistrict, Shenzhen,China Phone:(626)588-8039+86-755-26648642 Email:[email protected]@163.com
Page 1 of 4FCC ID: 2AUDZ-H01 Dongguan Yaxu (AiT) Technology Limited No. 22, Jinqianling 3rd Street, Jitigang, Huangjiang, Dongguan, Guangdong, China. External Photos Photo 1 Photo 2 Page 2 of 4FCC ID: 2AUDZ-H01 Dongguan Yaxu (AiT) Technology Limited No. 22, Jinqianling 3rd Street, Jitigang, Huangjiang, Dongguan, Guangdong, China. Photo 3 Photo 4 Page 3 of 4FCC ID: 2AUDZ-H01 Dongguan Yaxu (AiT) Technology Limited No. 22, Jinqianling 3rd Street, Jitigang, Huangjiang, Dongguan, Guangdong, China. Photo 5 Photo 6 Page 4 of 4FCC ID: 2AUDZ-H01 Dongguan Yaxu (AiT) Technology Limited No. 22, Jinqianling 3rd Street, Jitigang, Huangjiang, Dongguan, Guangdong, China. Photo 7 Photo 8 ------End------
Label FCCID:2AUDZ-H01
Page 1 of 9FCC ID: 2AUDZ-H01 Dongguan Yaxu (AiT) Technology Limited No. 22, Jinqianling 3rd Street, Jitigang, Huangjiang, Dongguan, Guangdong, China. Internal Photos Photo 1 Photo 2 Page 2 of 9FCC ID: 2AUDZ-H01 Dongguan Yaxu (AiT) Technology Limited No. 22, Jinqianling 3rd Street, Jitigang, Huangjiang, Dongguan, Guangdong, China. Photo 3 Photo 4 Page 3 of 9FCC ID: 2AUDZ-H01 Dongguan Yaxu (AiT) Technology Limited No. 22, Jinqianling 3rd Street, Jitigang, Huangjiang, Dongguan, Guangdong, China. Photo 5 Photo 6 Page 4 of 9FCC ID: 2AUDZ-H01 Dongguan Yaxu (AiT) Technology Limited No. 22, Jinqianling 3rd Street, Jitigang, Huangjiang, Dongguan, Guangdong, China. Photo 7 Photo 8 Page 5 of 9FCC ID: 2AUDZ-H01 Dongguan Yaxu (AiT) Technology Limited No. 22, Jinqianling 3rd Street, Jitigang, Huangjiang, Dongguan, Guangdong, China. Photo 9 Photo 10 Page 6 of 9FCC ID: 2AUDZ-H01 Dongguan Yaxu (AiT) Technology Limited No. 22, Jinqianling 3rd Street, Jitigang, Huangjiang, Dongguan, Guangdong, China. Photo 11 Photo 12 Page 7 of 9FCC ID: 2AUDZ-H01 Dongguan Yaxu (AiT) Technology Limited No. 22, Jinqianling 3rd Street, Jitigang, Huangjiang, Dongguan, Guangdong, China. Photo 13 Photo 14 Page 8 of 9FCC ID: 2AUDZ-H01 Dongguan Yaxu (AiT) Technology Limited No. 22, Jinqianling 3rd Street, Jitigang, Huangjiang, Dongguan, Guangdong, China. Photo 15 Photo 16 Page 9 of 9FCC ID: 2AUDZ-H01 Dongguan Yaxu (AiT) Technology Limited No. 22, Jinqianling 3rd Street, Jitigang, Huangjiang, Dongguan, Guangdong, China. Photo 17 Photo 18 ------End------ Antenna
Page 1 of 8Report No.: AiTDG-260803018W3 Note: This device has been tested and found to comply with the standard(s) listed, this test report merely corresponds to the test sample. It is not permitted to copy extracts of these test result without the written permission of the test laboratory. This report shall not be reproduced except in full, without the written approval of Dongguan Yaxu (AiT) Technology Limited. If there is a need to alter or revise this document, the right belongs to Dongguan Yaxu (AiT) Technology Limited, and it should give a prior written notice of the revision document. This test report must not be used by the client to claim product endorsement. Dongguan Yaxu (AiT) Technology Limited No. 22, Jinqianling 3rd Street, Jitigang, Huangjiang, Dongguan, Guangdong, China. RF Exposure evaluation Product Name: Magnetic Photo Grip Brand Name: N/A Model: H01 Series Model: H02, H03, H05, H06, H08, H09, H10, H12 FCCID: 2AUDZ-H01 Applicant: Shenzhen Keithy Innovation Technology Co., Ltd. Address: RM101, Building B, Mili Cultural and Creative Park, No. 6, Changfa East Road, Yangmei Community, Bantian Street, Longgang District, Shenzhen, China Manufacturer: Shenzhen Keithy Innovation Technology Co., Ltd. Address: RM101, Building B, Mili Cultural and Creative Park, No. 6, Changfa East Road, Yangmei Community, Bantian Street, Longgang District, Shenzhen, China Standard(s): 47CFR§1.1310,47CFR §2.1093 KDB447498 D01 General RF Exposure Guidance v06 Date of Receipt: Aug. 03, 2026 Date of Test: Aug. 03, 2026~Aug. 24, 2026 Issued Date: Aug. 25, 2026 Issued By: Dongguan Yaxu (AiT) Technology Limited No. 22, Jinqianling 3rd Street, Jitigang, Huangjiang, Dongguan, Guangdong, China Tel.: +86-769-8202 0499 Fax.: +86-769-8202 0495 Reviewed by:Approved by: Emiya LinSimba Huang Page 2 of 8 Report No.: AiTDG-260803018W3 Report Revise Record Report VersionIssued DateNotes V1.0Aug. 25, 2026Initial Release Page 3 of 8 Report No.: AiTDG-260803018W3 Contents 1 GENERAL INFORMATION.............................................................................................................................................4 1.1ENVIRONMENTAL CONDITIONS........................................................................................................................................4 1.2GENERALDESCRIPTION OFEUT......................................................................................................................................4 1.3TESTFACILITY...............................................................................................................................................................5 1.4MEASUREMENT UNCERTAINTY........................................................................................................................................ 6 2 METHOD OF MEASUREMENT......................................................................................................................................7 2.1APPLICABLESTANDARD................................................................................................................................................. 7 2.2EVALUATIONMETHOD ANDLIMIT...................................................................................................................................7 2.3MANUFACTURINGTOLERANCE........................................................................................................................................8 2.4EVALUATIONRESULT......................................................................................................................................................8 2.5CONCLUSION................................................................................................................................................................8 Page 4 of 8 Report No.: AiTDG-260803018W3 1 GENERAL INFORMATION 1.1 Environmental conditions During the measurement the environmental conditions were within the listed ranges: Normal Temperature:25°C Relative Humidity:55 % Air Pressure:101 kPa 1.2 General Descriptionof EUT Product Name:Magnetic Photo Grip Model/Type reference: H01 Serial Model:H02, H03, H05, H06, H08, H09, H10, H12 Power Supply: Grip: Input: Type-C USB DC 5V Output: Contact DC 5V Battery: 3.7V 500mAh 1.85Wh Controller: Input: Contact DC 5V Battery: 3.7V 50mAh 0.185Wh Hardware version.:N/A Software version.:N/A Test sample(s) ID:AiTDG-260803018-1 BT: Modulation:GFSK Operation frequency:2402MHz-2480MHz Channel number:40 Channels Channel separation:2MHz Antenna type:PCB Antenna Antenna gain:-0.08dBi Remark:The above DUT's information was declared by manufacturer. For more detailed features description, please refer to the manufacturer’s specifications or the User's Manual. Page 5 of 8 Report No.: AiTDG-260803018W3 1.3 Test Facility Test Laboratory: Dongguan Yaxu (AiT) Technology Limited No. 22, Jinqianling 3rd Street, Jitigang, Huangjiang, Dongguan, Guangdong, China The test facility is recognized, certified or accredited by the following organizations: CNAS-Registration No: L6177 Dongguan Yaxu (AiT) technology Limited is accredited to ISO/IEC 17025:2017 general Requirements for the competence of testing and calibration laboratories (CNAS-CL01 Accreditation Criteria for the competence of testing and calibration laboratories) on April 18, 2022 FCC-Registration No.: 362653 Designation Number: CN1457 Dongguan Yaxu (AiT) Technology Limited has been registered and fully described in a report filed with the (FCC) Federal Communications Commission. The acceptance letter from the FCC is maintained in our files. IC-Registration No.: 6819A CAB identifier: CN0122 The 3m Semi-anechoic chamber of Dongguan Yaxu (AiT) Technology Limited has been registered by Certification and Engineering Bureau of Industry Canada for radio equipment testing with Registration No.: 6819A A2LA-Lab Cert. No.: 6317.01 Dongguan Yaxu (AiT) Technology Limited has been accredited by A2LA for technical competence in the field of e…
Text truncated - open the document above for the full version.
Page 1 of 35Report No.: AiTDG-260803018W2 Dongguan Yaxu (AiT) Technology Limited No. 22, Jinqianling 3rd Street, Jitigang, Huangjiang, Dongguan, Guangdong, China. TEST REPORT Client Information: Applicant:Shenzhen Keithy Innovation Technology Co., Ltd. Applicant add.: RM101, Building B, Mili Cultural and Creative Park, No. 6, Changfa East Road, Yangmei Community, Bantian Street, Longgang District, Shenzhen, China Manufacturer:Shenzhen Keithy Innovation Technology Co., Ltd. Manufacturer add.: RM101, Building B, Mili Cultural and Creative Park, No. 6, Changfa East Road, Yangmei Community, Bantian Street, Longgang District, Shenzhen, China Product Information: Product Name:Magnetic Photo Grip Model No:H01, H02, H03, H05, H06, H08, H09, H10, H12 Brand Name:N/A FCC ID:2AUDZ-H01 Applicable standards: FCC CFR Title 47 Part 15 Subpart C Section 15.247 Prepared By: Dongguan Yaxu (AiT) Technology Limited No. 22, Jinqianling 3rd Street, Jitigang, Huangjiang,Dongguan, Guangdong, China Tel.: +86-769-8202 0499Fax.: +86-769-8202 0495 Date of Receipt: Aug. 03, 2026Date of Test: Aug. 03, 2026~Aug. 24, 2026 Date of Issue:Aug. 25, 2026Test Result: Pass This device described above has been tested by Dongguan Yaxu (AiT) Technology Limited and the test results show that the equipment under test (EUT) is in compliance with the FCC requirements. And it is applicable only to the tested sample identified in the report. Note: This report shall not be reproduced except in full, without the written approval of Dongguan Yaxu (AiT) Technology Limited, this document may be altered or revised by Dongguan Yaxu (AiT) Technology Limited, personal only, and shall be noted in the revision of the document. This test report must not be used by the client to claim product endorsement. Reviewed by:Approved by: Emiya LinSimba Huang Page 2 of 35Report No.: AiTDG-260803018W2 Dongguan Yaxu (AiT) Technology Limited No. 22, Jinqianling 3rd Street, Jitigang, Huangjiang, Dongguan, Guangdong, China. 1 Contents Page COVER PAGE 1 CONTENTS...........................................................................................................................................................................2 2 TEST SUMMARY.................................................................................................................................................................4 2.1 Statement of the Measurement Uncertainty........................................................................................4 2.2 Measurement Uncertainty....................................................................................................................4 3 TEST FACILITY....................................................................................................................................................................5 3.1 Deviation from standard.......................................................................................................................5 3.2 Abnormalities from standard conditions...............................................................................................5 3.3 Test Location.........................................................................................................................................5 4 GENERAL INFORMATION................................................................................................................................................6 4.1 Test frequencies................................................................................................................................... 7 4.2 EUT Peripheral List.............................................................................................................................. 7 4.3 Test Peripheral List...............................................................................................................................7 4.4 TEST METHODOLOGY.......................................................................................................................8 4.4.1 EUT Configuration.............................................................................................................................8 4.4.2 EUT Exercise.....................................................................................................................................8 4.4.3 General Test Procedures.................................................................................................................. 8 4.5 Description of Test Modes....................................................................................................................9 5 EQUIPMENT USED DURING TEST...............................................................................................................................10 6 TEST RESULTS AND MEASUREMENT DATA..........................................................................................................12 6.1 Antenna requirement..........................................................................................................................12 6.2 On Time and Duty Cycle.................................................................................................................... 13 6.3 Maximum Conducted Output Power Measurement.......................................................................... 14 6.4 6 dB Spectrum Bandwidth Measurement..........................................................................................15 6.5 Power Spectral Density......................................................................................................................16 6.6 Conducted Spurious Emissions and Band Edges Test.....................................................................17 6.7 Restrict-band Band-edge Measurements..........................................................................................18 6.8 Radiated Emissions Measurement.........................................................................…
Text truncated - open the document above for the full version.
Lenze Technology Co.,LTD Tel:+86 0755-82031775;25332530 Fax:+86 0755-82713604 26c newspaper west tower, 6008 shennan Avenue,Futian District, Shenzhen City, GuangdongProvince,China GENERAL INFORMATION 1.1 Test Environment Condition Ambient Temperature 19 to 25 °C Ambient Relative 45 to 55 % Humidity Ambient Pressure N/A (Not applicable) 1.2 Announce (1) The test report is invalid if not marked with the signatures of the persons responsible for preparing and approving the test report. (2) The test report is invalid if there is any evidence and/or falsification. (3) The results documented in this report apply only to the tested sample, under the conditions and modes of operation as described herein. (4) This document may not be altered or revised in any way unless done so and all revisions are duly noted in the revisions section. (5) Content of the test report, in part or in full, cannot be used for publicity and/or promotional purposes without prior written approval from the laboratory. Lenze Technology Co.,LTD Tel:+86 0755-82031775;25332530 Fax:+86 0755-82713604 26c newspaper west tower, 6008 shennan Avenue,Futian District, Shenzhen City, GuangdongProvince,China PRODUCT INFORMATION 2.1 Applicant Applicant Lenze Technology Co.,LTD Address d.c., 26c newspaper west tower, 6008 shennan Avenue, Futian District , Contact Person Tony Telephone Number +86 0755-82031775;25332530 Fax Number +86 0755-82713604 E-mail Address [email protected] 2.2 Manufacturer Manufacturer Lenze Technology Co.,LTD Address d.c., 26c newspaper west tower, 6008 shennan Avenue, Futian District , Shenzhen City, Guangdong Province, China Contact Person N/A Telephone Number N/A Fax Number N/A E-mail Address N/A 2.3 General Description for Equipment under Test (EUT) EUT Type Bluetooth Antenna Model Name PCB Antenna Antenna Type PCB Antenna Hardware Version N/A Serial Number N/A Dimensions N/A 2.4 Technical Information Frequency Range 2400MHz~ 2500MHz Test Frequencies 2402MHz, 2441MHz, 2480MHz Lenze Technology Co.,LTD Tel:+86 0755-82031775;25332530 Fax:+86 0755-82713604 26c newspaper west tower, 6008 shennan Avenue,Futian District, Shenzhen City, GuangdongProvince,China SUMMARY OF TEST RESULTS 3.1 Test Standards No. Identity Document Title 1 IEEE149-1979 IEEE Standard Test Procedures for Antennas 3.2Test Verdict Report Section Description Remark ANNEX A.1 Gain And Efficiency -- ANNEX B Radiation Pattern -- 3.3Test Uncertainty The uncertainty is calculated using the methods suggested in the "Guide to the Expression of Uncertainty in Measurement" (GUM) published by ISO. Item Uncertainty VSWR(S11) 0.4 Gain -0.08dBi Lenze Technology Co.,LTD Tel:+86 0755-82031775;25332530 Fax:+86 0755-82713604 26c newspaper west tower, 6008 shennan Avenue,Futian District, Shenzhen City, GuangdongProvince,China GENERAL TEST CONFIGURATIONS 4.1 Test Condition Environment Parameter Selected Values During Tests Temperature Voltage Relative Humidity Normal Temperature, Normal Voltage 25°C N/A 51% (NTNV) 4.2 Test Equipment List Description Manufacturer Model Serial No. Cal. Date Cal. Due Vector Network Agilent E5071C MY46103472 2014.09.07 2015.09.06 Analyzer 5*5*5 Full Anechoic SATIMO 5*5*5 N/A 2014.09.05 2015.09.04 Chamber SG24 Multi-probe Antenna Measurement SATIMO SG24-L 1101855-0001 2014.10.25 2015.10.24 System 4.3 Test Setup Lenze Technology Co.,LTD Tel:+86 0755-82031775;25332530 Fax:+86 0755-82713604 26c newspaper west tower, 6008 shennan Avenue,Futian District, Shenzhen City, GuangdongProvince,China ANNEX A TEST RESULTS A.1 Gain and Efficiency Frequency Gain (dBi) Efficiency (%) 2402MHz -0.08 0.99 2441MHz -0.21 1.06 2480MHz -0.18 1.12 ANNEX B RADIATION PATTERN 3DPattern 2402MHZ Lenze Technology Co.,LTD Tel:+86 0755-82031775;25332530 Fax:+86 0755-82713604 26c newspaper west tower, 6008 shennan Avenue,Futian District, Shenzhen City, GuangdongProvince,China 2480MHZ 1D Radiation Pattern PHI =0 Lenze Technology Co.,LTD Tel:+86 0755-82031775;25332530 Fax:+86 0755-82713604 26c newspaper west tower, 6008 shennan Avenue,Futian District, Shenzhen City, GuangdongProvince,China PHI =90 THETA = 90 Lenze Technology Co.,LTD Tel:+86 0755-82031775;25332530 Fax:+86 0755-82713604 26c newspaper west tower, 6008 shennan Avenue,Futian District, Shenzhen City, GuangdongProvince,China ANNEX C TEST SETUP PHOTO ANNEX D EUT PHOTO Antenna shape
Dongguan Yaxu (AiT) Technology Limited Report No.:AiTDG-260803018W2 FCC ID: 2AUDZ-H01 Page 1 of 35 Appendix B RF Test Data for BT (BLE) (Conducted Measurement) Product Name: Magnetic Photo Grip Trade Mark: N/A Test Model: H01 Environmental Conditions Temperature: 24.6 C Relative Humidity:52.4% ATM Pressure:100.0 kPa Test Engineer:Emiya Lin Supervised by:Simba Huang Dongguan Yaxu (AiT) Technology Limited Report No.:AiTDG-260803018W2 FCC ID: 2AUDZ-H01 Page 2 of 35 Contents Page COVER PAGE 1 Duty Cycle........................................................................................................................................................................................ 3 1.1 Test Result............................................................................................................................................................................3 1.2 Test Graphs...........................................................................................................................................................................4 2 Maximum Conducted Output Power................................................................................................................................................. 7 2.1 Test Result............................................................................................................................................................................7 2.2 Test Graphs...........................................................................................................................................................................8 3 -6dB Bandwidth...............................................................................................................................................................................11 3.1 Test Result.......................................................................................................................................................................... 11 3.2 Test Graphs.........................................................................................................................................................................12 4 Maximum Power Spectral Density Level.........................................................................................................................................15 4.1 Test Result..........................................................................................................................................................................15 4.2 Test Graphs.........................................................................................................................................................................16 5 Band Edge......................................................................................................................................................................................19 5.1 Test Result..........................................................................................................................................................................19 5.2 Test Graphs.........................................................................................................................................................................20 6 Conducted RF Spurious Emission.................................................................................................................................................. 24 6.1 Test Result..........................................................................................................................................................................24 6.2 Test Graphs.........................................................................................................................................................................25 7 Restrict Band.................................................................................................................................................................................. 31 7.1 Test Result..........................................................................................................................................................................31 7.2 Test Graphs.........................................................................................................................................................................32 Dongguan Yaxu (AiT) Technology Limited Report No.:AiTDG-260803018W2 FCC ID: 2AUDZ-H01 Page 3 of 35 1 Duty Cycle 1.1 Test Result ModeFrequency (MHz)Duty Cycle (%)Correction Factor 1/T (kHz) BLE 1M240210000 BLE 1M244010000 BLE 1M248010000 BLE 2M240210000 BLE 2M244010000 BLE 2M248010000 Dongguan Yaxu (AiT) Technology Limited Report No.:AiTDG-260803018W2 FCC ID: 2AUDZ-H01 Page 4 of 35 1.2 Test Graphs Test Graphs BLE 1M 2402MHz BLE 1M 2440MHz Dongguan Yaxu (AiT) Technology Limited Report No.:AiTDG-260803018W2 FCC ID: 2AUDZ-H01 Page 5 of 35 BLE 1M 2480MHz BLE 2M 2402MHz Dongguan Yaxu (AiT) Technology Limited Report No.:AiTDG-260803018W2 FCC ID: 2AUDZ-H01 Page 6 of 35 BLE 2M 2440MHz BLE 2M 2480MHz Dongguan Yaxu (AiT) Technology Limited Report No.:AiTDG-260803018W2 FCC ID: 2AUDZ-H01 Page 7 of 35 2 Maximum Conducted Output Power 2.1 Test Result ModeFrequency (MHz)Conducted Power (dBm) Limit (dBm)Verdict BLE 1M2402-0.2930Pass BLE 1M2440-0.5830Pass BLE 1M2480-0.5130Pass BLE 2M2402-0.3130Pass BLE 2M2440-0.5830Pass BLE 2M2480-0.530Pass Dongguan Yaxu (AiT) Technology Limited Report No.:AiTDG-260803018W2 FCC ID: 2AUDZ-H01 Page 8 of 35 2.2 Test Graphs Test Graphs BLE 1M 2402MHz BLE 1M 2440MHz Dongguan Yaxu (AiT) Technology Limited Report No.:AiTDG-260803018W2 FCC ID: 2AUDZ-H01 Page 9 of 35 BLE 1M 2480MHz BLE 2M 2402MHz Dongguan Yaxu (AiT) Technology Limited Report No.:AiTDG-260803018W2 FCC ID: 2AUDZ-H01 Page 10 of 35 BLE 2M 2440MHz BLE 2M 2480MHz Dongguan Yaxu (AiT) Technology Limited Report No.:AiTDG-260803018W2 FCC ID: 2AUDZ-H01 Page 11 o…
Text truncated - open the document above for the full version.
Page 1 of 2 FCC ID:2AUDZ-H01 Dongguan Yaxu (AiT) Technology Limited No. 22, Jinqianling 3rd Street, Jitigang, Huangjiang, Dongguan, Guangdong, China. Test Setup Photo Radiated Emission Page 2 of 2 FCC ID:2AUDZ-H01 Dongguan Yaxu (AiT) Technology Limited No. 22, Jinqianling 3rd Street, Jitigang, Huangjiang, Dongguan, Guangdong, China. Conducted Emission RF Conduction ------End------
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 900.00 µW |

Touch-Control Wireless Selfie Live Streaming Projector
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
video doorbell
Equipment Class
DTS - Digital Transmission System
Dashboard Camera
Equipment Class
DTS - Digital Transmission System2.4G Wireless Video Doorbell
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Selfie Stick Tripod
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter