FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Hangzhou Bangtang Network Technology Co., Ltd./
  3. 2AUHA-FMLILAC101

2AUHA-FMLILAC101LIac Kegel Exerciser

Hangzhou Bangtang Network Technology Co., Ltd.
LIac Kegel Exerciser - FCC ID 2AUHA-FMLILAC101 - Hangzhou Bangtang Network Technology Co., Ltd.
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Jun 18, 2020
Application Purpose
Original Equipment
Date of Application
Jun 18, 2020
Equipment Note
LIac Kegel Exerciser
Frequency Range
2402.00000000 - 2480.00000000
Company
Hangzhou Bangtang Network Technology Co., Ltd.
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Femometer Lilac Kegel Exerciser Model Prchased: Name: Serial Number: Phone Number: Data of Purchase: E-Mail Address: FM-Lilac-101 FCC Warning Statement Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: ‐‐ Reorient or relocate the receiving antenna. ‐‐ Increase the separation between the equipment and receiver. ‐‐Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. ‐‐ Consult the dealer or an experienced radio/TV technician for help. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

Cover Letter(s)

Hangzhou Bangtang Network Technology Co., Ltd. Agent Authorization Company: Hangzhou Bangtang Network Technology Co., Ltd. Address: F12 No.92 Yueda Valley, Binjiang District, Hangzhou 310058, China Product Name: LIac Kegel Exerciser Model Number(s): FM-LILAC-101 Product Description: LIac Kegel Exerciser We authorize MiCOM Labs Inc., 575 Boulder Court, Pleasanton, California 94566, USA, to act on our behalf on all matters concerning the certification of above named equipment. We declare that MiCOM Labs Inc. is allowed to forward all information related to the approval and certification of equipment to the regulatory agencies as required and to discuss any issues concerning the approval application. Any and all acts carried out by MiCOM Labs on our behalf shall have the same effect as acts of our own. Signature: Date: Jun. 18, 2020 Name: Wang Junjie Title: Product Director Company: Hangzhou Bangtang Network Technology Co., Ltd.

Cover Letter(s)

Hangzhou Bangtang Network Technology Co., Ltd. Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 USA Date: Jun. 18, 2020 Subject; Request for Confidentiality FCC ID: 2AUHA-FMLILAC101 To Whom It May Concern, Pursuant to the provisions of the Commission’s rules Title 47 Sections §0.457 and §0.459, we are requesting the Commission to withhold the following attachment(s) as confidential documents from public disclosure indefinitely. These documents contain detailed system and equipment descriptions and are considered as proprietary information in operation of the equipment. The public disclosure of these documents might be harmful to our company and would give competitors an unfair advantage in the market. Schematic Diagram Block Diagram Parts List Operational Description It is our understanding that all measurement test reports, FCC ID label format and correspondence during the certification review process cannot be granted as confidential documents and this information will be available for public review once the grant of equipment authorization is issued. Sincerely, Signature: Name: Wang Junjie Title: Product Director

External Photos

Annex A External Photos Report No.:HK2006091311-E Page 1 of 4 Report No.:HK2006091311-E Page 2 of 4 Report No.:HK2006091311-E Page 3 of 4 Report No.:HK2006091311-E Page 4 of 4

ID Label/Location Info

FCC ID LABEL: Ca. 5mm x 8mm Label Location FCC ID: 2AUHA-FMLILAC101

Internal Photos

Annex B Internal Photo Report No.:HK2006091311-E Page 1 of 4 Report No.HK2006091311-E Page 2 of 4 Antenna Report No.HK2006091311-E Page 3 of 4 Report No.HK2006091311-E Page 4 of 4

RF Exposure Info

FCC RF Exposure EUT Description: LIac Kegel Exerciser Model No.: FM‐LILAC‐101 FCC ID: 2AUHA‐FMLILAC101 1. Limits According to KDB 447498 D01 General RF Exposure Guidance v06 The 1‐g and 10‐g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation distances ≤50 mm are determined by: [(max power of channel, including tune‐up tolerance, mW)/(min. test separation distance, mm)] ·[√ f(GHz)]≤3.0 for 1‐g SAR and ≤ 7.5 for 10‐g extremity SAR, Where: Result=P/D*√F F= the RF channel transmit frequency in GHz P=Maximum turn‐up power in mw D=Min. test separation distance in mm 2. Test Result of RF Exposure Evaluation 2.4G Output power ( dBm) Tune Up Power (dBm) Max Tune Up power dBm/mW Min test separatio n distance mm Result Limit SAR Test Exclusion BT ‐6.497 ‐7±1 ‐6/ 0.25 5 0.07749 3.0 Pass Note: PK Output power= conducted power. Conducted power see the test report HK2006091311‐E, antenna gain=0dBi Per KDB 447498 D01, when the minimum test separation distance is < 5 mm, a distance of 5 mm is applied to determine RF Exposure test exclusion. The test exclusion threshold is 0.07749 which is<= 3, RF Exposure testing is not required. Note: Exclusion Thresholds Results=[(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance, mm)] ·[√f(GHz)] f(GHz) is the RF channel transmit frequency in GHz Distance=5mm

Test Report

Page 1 of 45 Report No.: HK2006091311-E TEST REPORT FCC PART 15 SUBPART C 15.247 Test report On Behalf of Hangzhou Bangtang Network Technology Co., Ltd. For LIac Kegel Exerciser Model No.: FM-LILAC-101 FCC ID: 2AUHA-FMLILAC101 Prepared for : Hangzhou Bangtang Network Technology Co., Ltd. F12 No.92 Yueda Valley, Binjiang District, Hangzhou 310058, China Prepared By : Shenzhen HUAK Testing Technology Co., Ltd. 1F, B2 Building, Junfeng Zhongcheng Zhizao Innovation Park, Fuhai Street, Bao'an District, Shenzhen City, China Date of Test: Jun. 12, 2020 ~ Jun. 19, 2020 Date of Report: Jun. 19, 2020 Report Number: HK2006091311-E Page 2 of 45 Report No.: HK2006091311-E TEST RESULT CERTIFICATION Applicant’s name ................... : Hangzhou Bangtang Network Technology Co., Ltd. Address .................................... : F12 No.92 Yueda Valley, Binjiang District, Hangzhou 310058, China Manufacture's Name .............. : Hangzhou Bangtang Network Technology Co., Ltd. Address .................................... : F12 No.92 Yueda Valley, Binjiang District, Hangzhou 310058, China Product description Trade Mark: N/A Product name ............................. : LIac Kegel Exerciser Model and/or type reference .. : FM-LILAC-101 Standards ................................ : 47 CFR FCC Part 15 Subpart C 15.247 This publication may be reproduced in whole or in part for non-commercial purposes as long as the Shenzhen HUAK Testing Technology Co., Ltd. is acknowledged as copyright owner and source of the material. Shenzhen HUAK Testing Technology Co., Ltd. takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. Date of Test .............................................. : Date (s) of performance of tests ................ : Jun. 12, 2020 ~ Jun. 19, 2020 Date of Issue ............................................. : Jun. 19, 2020 Test Result ................................................. : Pass Prepared by: Project Engineer Reviewed by: Project Supervisor Approved by: Technical Director Page 3 of 45 Report No.: HK2006091311-E Contents Page CONTENTS .............................................................................................................................................................. 3 1 TEST SUMMARY ............................................................................................................................................ 6 1.1 TEST DESCRIPTION ...................................................................................................................................... 6 1.2 MEASUREMENT UNCERTAINTY ...................................................................................................................... 7 2 TEST FACILITY ............................................................................................................................................... 8 3 GENERAL INFORMATION ............................................................................................................................. 8 3.1 GENERAL DESCRIPTION OF EUT .................................................................................................................. 8 3.2 DESCRIPTION OF TEST CONDITIONS ............................................................................................................ 10 3.3 DESCRIPTION OF TEST SETUP ........................................................................................................... 10 4 EQUIPMENTS LIST FOR ALL TEST ITEMS ............................................................................................... 11 5 TEST RESULT .............................................................................................................................................. 13 5.1 ANTENNA REQUIREMENT ............................................................................................................................ 13 5.1.1 Standard requirement ...................................................................................................................... 13 5.1.2 EUT Antenna ................................................................................................................................... 13 5.2 CONDUCTION EMISSIONS MEASUREMENT ................................................................................................... 14 5.2.1 Applied procedures / Limit ............................................................................................................... 14 5.2.2 Test procedure ................................................................................................................................. 14 5.2.3 Test setup ........................................................................................................................................ 15 5.2.4 Test results ...................................................................................................................................... 16 5.3 RADIATED EMISSIONS MEASUREMENT ........................................................................................................ 18 5.3.1 Applied procedures / Limit ............................................................................................................... 18 5.3.2 Test setup ........................................................................................................................................ 18 5.3.3 Test Result ....................................................................................................................................... 20 5.4 MAXIMUM OUTPUT POWER MEASUREMENT ................................................................................................. 27 5.4.1 Limit ................................................................................................................................................. 27 5.4.2 Test procedure ..........…

Text truncated - open the document above for the full version.

Test Setup Photos

Test model: FM-LILAC-101 Radiated Emission Conducted Emission

Contact Information

Applicant

Wang Junjie(Product Director)
[email protected]+86 13957144456Fax: 86-0571-56560756

Technical Contact

Hangzhou Bangtang Network Technology Co., Ltd.
[email protected]

China

Test Firm

Shenzhen HUAK Testing Technology Co., Ltd.Jason Zhou
[email protected]+86-755-23029901

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz220.00 µW
Confidentiality
Long Term
Grant Notes
Output power listed is conducted power.

Other Applications from Hangzhou Bangtang Network Technology Co., Ltd.

Basal Thermometer with Bluetooth - FCC ID 2AUHAVC101 - Hangzhou Bangtang Network Technology Co., Ltd.
2AUHAVC101

Basal Thermometer with Bluetooth

Aug 25, 2020

Equipment Class

DTS - Digital Transmission System
IVY - FCC ID 2AUHAFM-IVY-101 - Hangzhou Bangtang Network Technology Co., Ltd.
2AUHAFM-IVY-101

IVY

Jan 19, 2020

Equipment Class

DTS - Digital Transmission System