FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Hangzhou Bangtang Network Technology Co., Ltd./
  3. 2AUHAFM-IVY-101

2AUHAFM-IVY-101IVY

Hangzhou Bangtang Network Technology Co., Ltd.
IVY - FCC ID 2AUHAFM-IVY-101 - Hangzhou Bangtang Network Technology Co., Ltd.
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Jan 19, 2020
Application Purpose
Original Equipment
Date of Application
Jan 19, 2020
Equipment Note
IVY
Frequency Range
2402.00000000 - 2480.00000000
Company
Hangzhou Bangtang Network Technology Co., Ltd.
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Product name: IVY Model: FM-IVY-101 Intended use21 2 Dos and Don’ts 3 3 How to use 4 4 Test result 6 5 Product structure 8 6 Legends 9 7 List of accessories 9 8 Product specifications 10 9 Q&A 10 10 Disclaimer 12 11 11Warranty 12Copyright statement 13 1313Certification 1414FCC warning 1615Quick Guide Table of Contents 1 1 Intended use This product is used for the qualitative detection of luteinizing hormone in human urine. Luteinizing hormone is a type of gonadotropins, LH for short and also known as interstitial cell-stimu- lating hormone (LCSH). It is produced by the basophils in the anterior pituitary, and interacts with mature follicles, leading to ovulation and producing corpus luteum. It is a key hormone that accelerates egg release and corpus luteum formation. Ovulation is only initiated when its secretion is normal and reaches a certain amount. Average women of childbearing age ovulate once a month. Ovulation normally happens between 12 to 16 days before next menstruation. The egg released can only survive for 12 to 30 hours. Sperms can be alive in genital meatus for 2 to 3 days. There are only a couple of hours that are crucial for conception. Therefore, accurate forecasts of ovulation are essential to guide women who are trying to conceive in choosing the best time for intercourse for higher conception probability. They are also significant to guide women who are on birth control to avoid intercourse during ovulation. Thank you for purchasing For the safe use of this product, please read this User Manual first, and keep it properly after reading so that you may access and consult at any time. The warranty card is also included in the package. Please do not lose it. 2 You can choose to use the urine of any of the three periods - morning, afternoon, or evening. The test strip in the bag should be used immediately after unpacking to avoid failure caused by dampness. Stop drinking water 2 hours before collecting the urine sample to prevent it from being diluted. There is a desiccant in the aluminum foil bag. Do not eat it. Product expired may not be used. The urine cup can be reused. Test strips are disposable and cannot be reused. Please discard the test strips in a non-recyclable bin after use. This product is for in vitro diagnostic use only. This product is an auxiliary diagnostic device only. It cannot determine the actual amount of LH in a urine sample. The test results cannot serve as a basis for diagnosis. The test result will be displayed through the LED light. Once the test is completed, the icon will be displayed for 30 seconds before it goes out. If you want to check the result again, simply pull out the test strip, or try to put the lid of Femometer IVY back on and pull it out again. The result from your latest test will be shown. Battery disposal must comply with the regulations of the national government and environmental protection agencies. 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 2 Dos and Don’ts Any measurement done by this product is for personal reference only. It is very dangerous for a patient to conduct self-diagnosis and self-treatment based on measurements only. Please be sure to follow your doctor’s instructions. Warning 3 Step 1: Remove the battery cover. Install the button cell in the direction as indicated. When you hear a beep, it indicates that the battery has been inserted successfully. Put the battery cover back in place. 3 How to use Step 3: Remove the lid of the main body. When you hear a beep, it indicates that Femometer IVY is on. Insert the test strip into the main body in the direction as indicated. (Please make sure that the test strip is inserted all the way to the bottom and the whole arrow has disappeared.) When the light starts to flash, it means the device is ready for the test. Step 2: Collect your urine in the cup included in the package. You can choose the urine from any of the three different time of the day - morning, afternoon and evening. CR2032 CR2032 4 3 How to use Step 4: Collect your urine in the cup included in the package. Dip the top of the test strip into the urine and hold it until you hear a "beep" (at the same time, the status light starts fast flashing). Then pull it out and put the test strip lid back on. Step 5: Place the product on a flat surface. The LED light will be flashing during the testing. Wait for about 6-10 minutes till you hear three beeps which indicate that the test is completed. The test result will be displayed via the LED light. If the light goes out after some time, pulling out the test strip, or putting back & pulling out the main body lid again will enable the last test result to show again. 6-10min 4 5 4 Test result Indicates a negative result with a low probability of conception. Please test again after 12 hours. To ensure the accuracy of the tests, please test every day. The measurement result will be displayed for 30 seconds. Symbol “-” Indicates a positive result in which the test line is lighter than the control line. When it detects the rise of Luteinizing Hormone for the first time, “+” will be displayed, which indicates a high probability of conception. Please test every 4-6 hours afterwards. But don’t drink too much liquid before testing. Symbol “+” 6 How to use Bluetooth: 1. Open the electronic device and APP. 2. Follow the APP prompts to bind the device. 3. After connecting, the data will be automatically synchronized via Bluetooth afterwards. 4 Test result Indicates a positive result where the test line is of the same color as or darker than the control line. LH surge is detected. And you have the highest probability of conception. Please keep testing every 4-6 hours until it shows "+", which indicates that you have ovulated. Symbol “++” 7 Femometer IVY consists of the main body, Lid of the main body, test strips, and battery cover. Lid of the main body Main body Test strip cover Test strips LED display 5 Product structure Battery cover 8 6 Legends 7 List of accessories Please confirm …

Text truncated - open the document above for the full version.

Cover Letter(s)

QA-FR-170-B Company: Hangzhou Bangtang Network Technology Co., Ltd. Add: F12 No.92 Yueda Valley, Binjiang District, Hangzhou, 310058 China Tel: +86 1395714 4456 Fax: 86-0571-56560756 E-mail: wangju [email protected] FCC Authorization Date: 2019-11-04 FEDERAL COMMUNICATIONS COMMISSION Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Subject: Agent Authorization To whom it may concern: We, Hangzhou Bangtang Network Technology Co., Ltd., the undersigned, Hereby authorizes Bay Area Compliance Laboratories Corporation to act on its behalf in all matters relating to application for Equipment authorization, including the signing of all documents relating to these matters. All acts carried out by Bay Area Compliance Laboratories Corp. o n our behalf shall have the same effect as our own action. We, the undersigned, hereby certify that we are not subject to a denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 862. This authorization is valid until further written notice from the applicant. Sincerely Yours, Signature: Typed or Printed Name: Zhang Guoliang Title: Product Director

Cover Letter(s)

Company: Hangzhou Bangtang Network Technology Co., Ltd. Add: F12 No.92 Yueda Valley, Binjiang District, Hangzhou, 310058 China Tel: +86 13957144456 Fax: 86-0571-56560756 E-mail: [email protected] FCC Confidential Authorization Date:2019-11-04 FEDERAL COMMUNICATIONS COMMISSIONS Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Subject: Confidentiality Request regarding application for certification of FCC ID: 2AUHAFM-IVY-101 To: whom it may concern, In accordance with Sections 0.457 and 0.459 of the Commission’s Rules, Hangzhou Bangtang Network Technology Co., Ltd. hereby requests long-term confidential treatment of information accompanying this application as outlined below: Block Diagram Schematics Operation Description The above materials contain proprietary and confidential information not customarily released to the public. The public disclosure of these materials provides unjustified benefits to its competitors in the market. Sincerely Yours, Signature: Typed or Printed Name: Zhang Guoliang Title: Product Director

External Photos

EXHIBIT A - EUT EXTERNAL PHOTOGRAPHS EUT – Top View EUT – Bottom View EUT – Front View EUT – Rear View EUT – Left View EUT – Right View

Internal Photos

EXHIBIT B - EUT INTERNAL PHOTOGRAPHS EUT – Cover off View-1 EUT – button cell View EUT – Cover off View-2 EUT – PCB Top View Antenna EUT – PCB Top Chip View EUT – PCB Bottom View EUT – Cover off View-3

Test Report

Note: This test report is prepared for the customer shown above and for the device described herein. It may not be duplicated or used in part without prior written consent from Bay Area Compliance Laboratories Corp. This report is valid only with a valid digital signature. The digital signature may be available only under the Adobe software above version 7.0. FCC PART 15.247 TEST REPORT For Hangzhou Bangtang Network Technology Co., Ltd. F12 No.92 Yueda Valley, Binjiang District, Hangzhou, 310058 China FCC ID: 2AUHAFM-IVY-101 Report Type: Original Report Product Type: IVY Test Engineer: Denn y Yang Re port Number: RHZ191104001-00A Re port Date:2019-12-12 Reviewed B y: Oscar Ye EMC Mana ger Prepared By: Bay Area Compliance Laboratories Corp. (Kunshan) No.248 Chenghu Road,Kunshan,Jiangsu province,China Tel: +86-0512-86175000 Fax: +86-0512-88934268 www.baclcorp.com.cn Bay Area Compliance Laboratories Corp. (Kunshan) Report No.: RHZ191104001-00A FCC Part 15.247 Page 2 of 35 TABLE OF CONTENTS GENERAL INFORMATION ...................................................................................................................................... 4 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT) .................................................................................... 4 OBJECTIVE .................................................................................................................................................................. 4 RELATED SUBMITTAL(S)/GRANT(S) ............................................................................................................................ 4 TEST METHODOLOGY ................................................................................................................................................. 4 MEASUREMENT UNCERTAINTY ................................................................................................................................... 5 TEST FACILITY ............................................................................................................................................................ 5 SYSTEM TEST CONFIGURATION ......................................................................................................................... 6 DESCRIPTION OF TEST CONFIGURATION ..................................................................................................................... 6 EQUIPMENT MODIFICATIONS ...................................................................................................................................... 6 EUT EXERCISE SOFTWARE ......................................................................................................................................... 6 SUPPORT EQUIPMENT LIST AND DETAILS ................................................................................................................... 8 EXTERNAL I/O CABLE ................................................................................................................................................. 8 BLOCK DIAGRAM OF TEST SETUP ............................................................................................................................... 9 SUMMARY OF TEST RESULTS ............................................................................................................................ 10 TEST EQUIPMENT LIST ........................................................................................................................................ 11 FCC§15.247 (I), §1.1310 &§2.1093 –RF EXPOSURE ............................................................................................. 12 MEASUREMENT RESULT ............................................................................................................................................ 12 FCC §15.203 - ANTENNA REQUIREMENT .......................................................................................................... 13 APPLICABLE STANDARD ........................................................................................................................................... 13 ANTENNA CONNECTOR CONSTRUCTION ................................................................................................................... 13 FCC §15.209, §15.205 & §15.247(d) - SPURIOUS EMISSIONS ............................................................................ 14 APPLICABLE STANDARD ........................................................................................................................................... 14 EUT SETUP ............................................................................................................................................................... 14 EMI TEST RECEIVER SETUP ...................................................................................................................................... 15 TEST PROCEDURE ...................................................................................................................................................... 15 FACTOR & OVER LIMIT CALCULATION (FOR BELOW 1GHZ) ..................................................................................... 15 CORRECTED AMPLITUDE & MARGIN CALCULATION (FOR ABOVE 1GHZ) ................................................................. 15 TEST RESULTS SUMMARY ......................................................................................................................................... 16 TEST DATA ............................................................................................................................................................... 16 FCC §15.247(a) (2) - 6 dB EMISSION BANDWIDTH............................................................................................ 25 APPLICABLE STANDARD .....................................................................................................................................…

Text truncated - open the document above for the full version.

Test Setup Photos

EXHIBIT C - TEST SETUP PHOTOGRAPHS Radiated Emissions (Below 1GHz) Radiated Emissions (Above 1GHz)

Contact Information

Applicant

Wang Junjie(Product Director)
[email protected]+86 13957144456Fax: 86-0571-56560756

Test Firm

Bay Area Compliance Laboratories Corp. (Kunshan)Mr. John Chan
[email protected]+86 0512 86175000

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz700.00 µW
Confidentiality
Long Term
Grant Notes
Output power listed is conducted.

Other Applications from Hangzhou Bangtang Network Technology Co., Ltd.

Basal Thermometer with Bluetooth - FCC ID 2AUHAVC101 - Hangzhou Bangtang Network Technology Co., Ltd.
2AUHAVC101

Basal Thermometer with Bluetooth

Aug 25, 2020

Equipment Class

DTS - Digital Transmission System
LIac Kegel Exerciser - FCC ID 2AUHA-FMLILAC101 - Hangzhou Bangtang Network Technology Co., Ltd.
2AUHA-FMLILAC101

LIac Kegel Exerciser

Jun 18, 2020

Equipment Class

DTS - Digital Transmission System