  3. 2AUHEVARIA-100

2AUHEVARIA-10010 inches Touch Panel

Harman Professional, Inc.
10 inches Touch Panel - FCC ID 2AUHEVARIA-100 - Harman Professional, Inc.
Click to zoom

Application Details

Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Date of Grant
Apr 12, 2023
Application Purpose
Original Equipment
Date of Application
Mar 28, 2023
Equipment Note
10 inches Touch Panel
Frequency Range
13.56000000 - 13.56000000
Company
Harman Professional, Inc.
Country
United States

Documents & Files

Select a file to view

Users Manual

↗
↗
↗

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

CONFIGURATION & PROGRAMMING MANUAL VARIA TOUCH PANELS VARIA SL50 5.5” ULTRA-SLIM WALL MOUNT TOUCH PANEL VARIA SL80 8” ULTRA-SLIM WALL MOUNT TOUCH PANEL VARIA 80 8” TOUCH PANEL VARIA 100 10.1” TOUCH PANEL VARIA 100N 10.1” TOUCH PANEL NO-COMM VARIA 150 15.6” TOUCH PANEL VARIA 150N 15.6” TOUCH PANEL NO-COMM AV FOR AN IT WORLD ® IMPORTANT SAFETY INSTRUCTIONS ESD Warning To avoid ESD (Electrostatic Discharge) damage to sensitive components, make sure you are properly grounded before touching any internal materials. When working with any equipment manufactured with electronic devices, proper ESD grounding procedures must be followed to make sure people, products, and tools are as free of static charges as possible. Grounding straps, conductive smocks, and conductive work mats are specifically designed for this purpose. These items should not be manufactured locally, since they are generally composed of highly resistive conductive materials to safely drain static discharges, without increasing an electrocution risk in the event of an accident. Anyone performing field maintenance should use an appropriate ESD field service kit complete with at least a dissipative work mat with a ground cord and a UL listed adjustable wrist strap with another ground cord. 1. READ these instructions. 2. KEEP these instructions. 3. HEED all warnings. 4. FOLLOW all instructions. 5. DO NOT use this apparatus near water. 6. CLEAN ONLY with dry cloth. 7. DO NOT block any ventilation openings. Install in accordance with the manufacturer's instructions. 8. DO NOT install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat. 9. DO NOT defeat the safety purpose of the polarized or grounding type plug. A polarized plug has two blades with one wider than the other. A grounding type plug has two blades and a third grounding prong. The wider blade or the third prong are provided for your safety. If the provided plug does not fit into your outlet, consult an electrician for replacement of the obsolete outlet. 10. PROTECT the power cord from being walked on or pinched, particularly at plugs, convenience receptacles, and the point where they exit from the apparatus. 11. ONLY USE attachments/accessories specified by the manufacturer. 12. USE ONLY with a cart, stand, tripod, bracket, or table specified by the manufacturer, or sold with the apparatus. When a cart is used, use caution when moving the cart/apparatus combination to avoid injury from tip-over. 13. UNPLUG this apparatus during lightning storms or when unused for long periods of time. 14. REFER all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way, such as power-supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped. 15. DO NOT expose this apparatus to dripping or splashing and ensure that no objects filled with liquids, such as vases, are placed on the apparatus. 16. To completely disconnect this apparatus from the AC Mains, disconnect the power supply cord plug from the AC receptacle. 17. Where the mains plug or an appliance coupler is used as the disconnect device, the disconnect device shall remain readily operable. 18. DO NOT overload wall outlets or extension cords beyond their rated capacity as this can cause electric shock or fire. VARIA Touch Panels - Configuration & Programming Manual 3 | TOC WATCH FOR THESE SYMBOLS: The exclamation point, within an equilateral triangle, is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the literature accompanying the product. The lightning flash with arrowhead symbol within an equilateral triangle is intended to alert the user to the presence of uninsulated “dangerous voltage” within the product’s enclosure that may be of sufficient magnitude to constitute a risk of electrical shock to persons. ESD Warning: The icon to the left indicates text regarding potential danger associated with the discharge of static electricity from an outside source (such as human hands) into an integrated circuit, often resulting in damage to the circuit. WARNING: To reduce the risk of fire or electrical shock, do not expose this apparatus to rain or moisture. WARNING: No naked flame sources – such as lighted candles – should be placed on the product. WARNING: Equipment shall be connected to a MAINS socket outlet with a protective earthing connection. CAUTION: To be installed by instructed, or skilled, persons only. WARNING: This product is intended to be operated ONLY from the voltages listed on the back panel or the recommended, or included power supply of the product. Operation from other voltages other than those indicated may cause irreversible damage to the product and void the products warranty. The use of AC Plug Adapters is cautioned because it can allow the product to be plugged into voltages in which the product was not designed to operate. If you are unsure of the correct operational voltage, please contact your local distributor and/or retailer. If the product is equipped with a detachable power cord, use only the type provided, or specified, by the manufacturer or your local distributor. WARNING: Do Not Open! Risk of Electrical Shock. Voltages in this equipment are hazardous to life. No user- serviceable parts inside. Refer all servicing to qualified service personnel. Place the equipment near a main power supply outlet and make sure that you can easily access the power breaker switch. BATTERY INFORMATION: This product contains batteries that are covered under the 2006/66/EC European Directive, which cannot be disposed of with normal household waste. Please follow local regulations. THIS PRODUCT CONTAINS A LITHIUM PACK OR COIN/BUTTON CELL BATTERY. IF MISUSED OR ABUSED THIS CAN RESULT IN:  Smoke or gas h…

Text truncated - open the document above for the full version.

Users Manual

VARIA Touch Panels - Configuration & Programming Manual 60 | TOC • Maximum supported number of active video windows displayed simultaneously on the panel: 2 While this limitation is not enforced (i.e the TPDesign5 application will allow you include any number of video windows in the panel design), attempting to display more than two active video windows at one time may have a negative impact on the panel’s overall performance. • Maximum supported resolution for video windows: 720dpi • Maximum supported frame rate for video windows: 30fps DEVICE - Sensors The Sensors page (FIG. 38) allows activation and optimization of the panel’s motion and light sensors. Sensors page options Motion Detection • The blue bar within the slide bar shows the current motion sensor reading. • The slide bar sets the motion sensor threshold.The threshold controls when a motion sensor channel is on. • The “walk” Varia shows bars on either side when the threshold is crossed (FIG.38). Wake on Motion Sense: Press this checkbox to wake up the panel if any motion detected crosses the threshold set by the Motion Detection slide bar. Wake on Motion Test: This selection only be enabled if Wake Panel On Motion Sense is enabled. Pressing the test button will initiate a test mode where the display will go to sleep and wait for motion to turn it on. It can be used to test your current Motion Detection threshold value. Light Sensor Level Value The blue bar within the slide bar displays the current light sensor reading. • The slide bar indicates the light sensor threshold. • The threshold controls when a Light Sensor Channel Code press will be generated. Light Sensor Calibration: Press to perform a calibration on the light sensor. See the Calibrating the Light Sensor section on page 36 for details. Light Sensor Level Port: Displays the current level port being used by the light sensor (read-only). Default = 1. Light Sensor Level Number: Displays the current level being used by the light sensor (read-only). Default = 0. Light Sensor Channel Port: Displays the current channel port being used by the light sensor (read-only). Default = 1. Light Sensor Channel Number: Displays the current channel being used by the light sensor (read-only). Default = 0. Motion Sensor Channel Port: Displays the current channel port being used by the motion sensor (read-only). Default = 1. Motion Sensor Channel Number: Displays the current channel being used by the motion sensor (read-only). Default = 0. Sensor Version: Displays the current sensor version (read-only). NOTE: Light and motion sensor ports, levels, and channels are configured in TPDesign 5. For more information on configuring light and motion sensors, please refer to the TPDesign 5 Operation/Reference Guide, available at www.amx.com. Calibrating the Light Sensor When the panel is installed for the first time, the light sensor should be calibrated to the room’s maximum ambient light condition. This calibration setting will be saved until the panel’s system settings are reset. VARIA Touch Panels - Configuration & Programming Manual 61 | TOC To calibrate the light sensor from the Settings pages: 1. From the Sensor Settings page, press Light Sensor Calibration. 2. Allow the panel 10 seconds to calibrate the room’s ambient light level. The indicator next to the button will show a rotating circle while calibration is in progress. DEVICE - VNC An on-board VNC (Virtual Network Computing) server allows the panel to connect to any remote PC running a VNC client. Once connected, the client can view and control the panel remotely. The options on the VNC page (FIG. 39) allow you to enable or disable VNC server functionality on the panel. FIG. 39 VNC page VNC page options Enable/Disable: The Enable/Disable button toggles between the two VNC settings: • Disable- deactivates the VNC server on the panel. • Enable - activates the VNC server on the panel (default setting). Timeout: Sets the length of time (in minutes) that the panel can remain idle, detecting no cursor movements, before the VNC session is terminated. (default = 15 minutes ). Password: Enter the VNC Authentication session password required for VNC access to the panel. Port: Use this field to enter the number of the port used by the VNC Web Server. Note that this field is enabled only while VNC is disabled (default = 5900) . Current Connections: Displays the number of users currently connected to this panel via VNC (read-only). Maximum Connections: Displays the maximum number of users that can be simultaneously connected to this panel via VNC. Press this field to increase the number allowed to connect to this panel. (default = 2 ). NOTE: The VNC server takes snapshots of the display buffer and sends them via VNC at a low frame rate Enabling VNC In the VNC page, press Enable/Disable to toggle VNC to ON (the default setting is OFF). Configuring VNC Access In the VNC page, use the options under VNC SERVER to configure various aspects of VNC access on the panel: • Press Timeout to specify a timeout period for VNC connections, in the Timeout window. Press OK to save changes • Press Password to assign the password to be required to establish a VNC connection, in the Password window. By default, no VNC password is set. Press OK to save changes. • Press Port to specify the port to be used by the VNC Web Server, in the Port window. This option is not available if VNC is currently enabled. Press OK to save changes. • Press Maximum Connections to set the maximum number of users that can be simultaneously connected to this panel via VNC. Press OK to save changes VARIA Touch Panels - Configuration & Programming Manual 62 | TOC CONNECTIONS - Ethernet The Ethernet page (FIG. 52) controls the configuration of settings for Ethernet communication with the panel. Scroll down to see all menu items FIG. 52 Ethernet page Ethernet page - IPV4 tab options DHCP/Static: Sets the panel to either DHCP or Static communication modes. • DHCP is an IP Address assigned to t…

Text truncated - open the document above for the full version.

Users Manual

VARIA Touch Panels - Configuration & Programming Manual 132 | TOC Text Effect Name/Numbers Text Effect Name/Numbers Number Name Number Name 0 None 30 Hard Drop Shadow 6 1 Outline -S 31 Hard Drop Shadow 7 2 Outline -M 32 Hard Drop Shadow 8 3 Outline -L 33 Soft Drop Shadow 1 with Outline 4 Outline -X 34 Soft Drop Shadow 2 with Outline 5 Glow -S 35 Soft Drop Shadow 3 with Outline 6 Glow -M 36 Soft Drop Shadow 4 with Outline 7 Glow -L 37 Soft Drop Shadow 5 with Outline 8 Glow -X 38 Soft Drop Shadow 6 with Outline 9 Soft Drop Shadow 1 39 Soft Drop Shadow 7 with Outline 10 Soft Drop Shadow 2 40 Soft Drop Shadow 8 with Outline 11 Soft Drop Shadow 3 41 Medium Drop Shadow 1 with Outline 12 Soft Drop Shadow 4 42 Medium Drop Shadow 2 with Outline 13 Soft Drop Shadow 5 43 Medium Drop Shadow 3 with Outline 14 Soft Drop Shadow 6 44 Medium Drop Shadow 4 with Outline 15 Soft Drop Shadow 7 45 Medium Drop Shadow 5 with Outline 16 Soft Drop Shadow 8 46 Medium Drop Shadow 6 with Outline 17 Med Drop Shadow 1 47 Medium Drop Shadow 7 with Outline 18 Med Drop Shadow 2 48 Medium Drop Shadow 8 with Outline 19 Med Drop Shadow 3 49 Hard Drop Shadow 1 with Outline 20 Med Drop Shadow 4 50 Hard Drop Shadow 2 with Outline 21 Med Drop Shadow 5 51 Hard Drop Shadow 3 with Outline 22 Med Drop Shadow 6 52 Hard Drop Shadow 4 with Outline 23 Med Drop Shadow 7 53 Hard Drop Shadow 5 with Outline 24 Med Drop Shadow 8 54 Hard Drop Shadow 6 with Outline 25 Hard Drop Shadow 1 55 Hard Drop Shadow 7 with Outline 26 Hard Drop Shadow 2 56 Hard Drop Shadow 8 with Outline 27 Hard Drop Shadow 3 28 Hard Drop Shadow 4 29 Hard Drop Shadow 5 VARIA Touch Panels - Configuration & Programming Manual 133 | TOC Dynamic Image Commands Dynamic Image Commands ^BBR Button State Bitmap Resource Command - Assign a resource to those buttons with a defined address range. • Syntax: “’^BBR-<vt addr range>,<button states range>,<resource name>,[optional bitmap index], [optional justification]’” • Variables: address range: Address codes of buttons to affect. A ‘.’ between addresses includes the range, and & between addresses includes each address. button states range: 1 - 256 for multi-state buttons (0 = All states, for General buttons, 1 = Off state and 2 = On state). resource name: name of resource Optional bitmap index: 1 - 5, the state bitmap index to assign the resource. If not present, will place the referenced resource in index 1. The indexes are defined as: 0 - Chameleon Image (if present) 1 - Bitmap 1 2 - Bitmap 2 3 - Bitmap 3 4 - Bitmap 4 5 - Bitmap 5 Optional justification: 0-11 (see Justification Values on page 166). If absolute justification (0) is set, the next two parameters are the X and Y offset of the bitmap for the referenced index. If no justification is specified, the current justification is used. • Example: SEND_COMMAND Panel,”’^BBR-500.504&510.515,1,image_xray’” Sets the OFF state picture for the buttons with variable text ranges of 500-504 & 510-515 to the resource named image_xray. ^RAF Resource Add Command - Add new resources. Adds any and all resource parameters by sending embedded codes and data. Since the embedded codes are preceded by a ‘%’ character, any ‘%’ character contained in the URL must be escaped with a second ‘%’ character (see example). The file name field (indicated by a %F embedded code) may contain special escape sequences as shown in the ^RAF, ^RMF - Embedded Codes table on page 141. Note: For server authentication to occur, the %U (username) and %S (password) Embedded Codes must be included, and they must match the credentials required by the server. • Syntax: “’^RAF-<resource name>,<data>’” • Variables: resource name: name of the resource to add. data: Refers to the embedded codes, see the ^RAF, ^RMF - Embedded Codes on page 141. Note: The %P, %U, %S, %H, %A, and %F values can be entered In a single string . • Example: SEND_COMMAND Panel,”’^RAF-New Image, %P0%HAMX.COM%ALab/Test%%5Ffile%Ftest.jpg’” Adds a new resource. The resource name is ‘New Image’ %P (protocol) is 0 for an HTTP connection %H (host name) is AMX.COM %A (file path) is Lab/Test_file %F (file name) is test.jpg. Note: the %%5F in the file path is actually encoded as %5F. ^RFR Refresh Resource Command - Force a refresh of the given resource. The command will refresh when the resource is visible onscreen. If it is not onscreen, it will be deferred until it is visible to do the refresh. An optional notification option can be set to receive a custom event from the panel when the resource refresh is complete. Optional width and height parameters can be specified to refresh the image at a specific resolution. If width and height parameters are not specified, the resource will be refreshed at the resolution(s) of any active buttons to which it is assigned. If there are no active buttons currently assigned that resource, it will be refreshed at its native resolution adjusted by any project scale factor. • Syntax: “’^RFR-<resource name>,[notification option],[width],[height]’” • Variables: Resource name: name of the resource to refresh Notification option: An optional notification option at the end of the command with the following possible values: On - notifications are sent whenever the named dynamic image resource is loaded/refreshed. Off - notifications are not sent (default). Once - notifications are sent one time whenever the named dynamic image resource is loaded/refreshed. Notifications are not sent on subsequent loads/refreshes. width: Specifies the width at which the resource should be refreshed (the image will be scaled as needed). height: Specifies the height at which the resource should be refreshed (the image will be scaled as needed). • Example: VARIA Touch Panels - Configuration & Programming Manual 134 | TOC SEND_COMMAND Panel,”’^RFR-Sports_Image,on’” Force a refresh on ‘Sport_Image’ when the resource is visible onscreen and enable completion notifications. SEND_COMMAND Panel,”’^RFR-Sports_Image,off’” Force a refresh on ‘Sport_Image’ when t…

Text truncated - open the document above for the full version.

Attestation Statements

Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: April 10, 2023 Ref: Attestation Statements Part 2.911(d)(5)(i)&(ii) Filing FCC ID: 2AUHEVARIA-100 Statement for 47 CFR section 2.911(d)(5)(i) Harman Professional, Inc. (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. Statement for 47 CFR section 2.911(d)(5)(ii) Harman Professional, Inc. (“the applicant”) certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. Sincerely, Signature: ____________________ Printed Name /Title: Caio Collet / Sr. Manager - Global Product Compliance Company Name: Harman Professional, Inc.

Cover Letter(s)

Harman Professional, Inc. 8500 Balboa Blvd. Northridge, CA 91329 USA +1 (818) 893-8411 Date: February 22, 2023 TO: Federal Communication Commission Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MID 21046 Regarding FCC ID: 2AUHEVARIA-100 To whom it may concern: We, the undersigned, hereby authorize SGS Taiwan Ltd. Jim Chang to act on our behalf in all manners relating to application for equipment authorization with respect to the FCC ID above, including signing of all documents relating to these matters. Any and all acts carried out by the agent on our behalf shall have the same effect as acts of our own. We, the undersigned, hereby certify that we are not subject to a denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 862. Further, no party, as defined in 47 CFR 1.2002 (b), to the application is subject to denial of federal benefits, that includes FCC benefits. We also declare that the information provided to the FCC is true and correct to the best of our knowledge (47 CFR 2.911(d)) and we have been informed of the grantee responsibilities (47 CFR 2.909) with regard to certified equipment. This authorization is valid until further written notice from the applicant. Sincerely, Signature: ____________________ Printed Name /Title: Caio Collet / Sr. Manager - Global Product Compliance Company Name: Harman Professional, Inc.

Cover Letter(s)

Harman Professional, Inc. 8500 Balboa Blvd. Northridge, CA 91329 USA +1 (818) 893-8411 Date: February 22, 2023 Federal Communication Commission Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MID 21046 REQUEST FOR CONFIDENTIALITY - FCC FCC ID: 2AUHEVARIA-100 Pursuant to Sections 0.457(d) and 0.459 of the Commission’s Rules and FCC Guidance document 726920, we hereby request permanent confidential treatment of exhibits identified as such in the table below and request they are permanently withheld from public review based on the documents containing trade secrets and proprietary information not customarily released to the public. The public disclosure of this information might be harmful to the applicant and provide unjustified benefits to its competitors. We also request short-term confidentiality on certain exhibits until the intended date of marketing as outlined below. We request the exhibits be withheld from public view for a period of 180 days. We attest marketing of the product will only commence after the period of short-term confidentiality expires, or if marketing is to commence before the requested number of days listed above, the grantee will inform Nemko to release the Short-Term Confidentiality information withheld on the FCC equipment authorization website. Exhibit Type of Confidentiality Requested Block Diagrams ☒ Permanent ☐ Short Term Operation Description ☒ Permanent ☐ Short Term Parts List & Placement/BOM ☐ Permanent ☐ Short Term Tune-Up Procedure ☐ Permanent ☐ Short Term Schematic Diagrams ☒ Permanent ☐ Short Term External Photos ------------------ ☒ Short Term Internal Photos ☐ Permanent* ☒ Short Term Test Setup Photos ------------------ ☒ Short Term User’s Manual ☐ Permanent* ☐ Short Term The asterisked items (*) require further information to be provided in this justification letter before permanent confidentiality will be extended to these exhibits. Please refer to FCC KDB 726920 D01 found at: https://apps.fcc.gov/oetcf/kdb/forms/FTSSearchResultPage.cfm?switch=P&id=41731 and review section II, 3) regarding specific information that must accompany these requests. Note: any documents held under the Short-Term confidentiality will automatically become public after the requested time if an appropriate extension request has not been received. Any exhibits (i.e., schematic diagrams) that may have already been requested to have “Permanent” confidentiality as shown above need not be repeated under Short-Term confidentiality request. Sincerely, Signed: Printed name: Caio Collet Title: Sr. Manager - Global Product Compliance Company Name: Harman Professional, Inc.

External Photos

Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only. 除非另有說明,此報告結果僅對測試之樣品負責,同時此樣品僅保留90天。本報告未經本公司書面許可,不可部份複製。 This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http://www.sgs.com.tw/Terms-and-Conditions and for electronic format documents, subject to Terms and Conditions for Electronic Documents at http://www.sgs.com.tw/Terms-and-Conditions. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. SGS Taiwan Ltd. No.134,Wu Kung Road, New Taipei Industrial Park, Wuku District, New Taipei City, Taiwan/新北市五股區新北產業園區五工路134號 台灣檢驗科技股份有限公司 t (886-2) 2299-3279 f (886-2) 2298-0488 www.sgs.com.tw Member of SGS Group Report No.: TERF2211002140ER-P Page: 1 of 9 External Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only. 除非另有說明,此報告結果僅對測試之樣品負責,同時此樣品僅保留90天。本報告未經本公司書面許可,不可部份複製。 This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http://www.sgs.com.tw/Terms-and-Conditions and for electronic format documents, subject to Terms and Conditions for Electronic Documents at http://www.sgs.com.tw/Terms-and-Conditions. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. SGS Taiwan Ltd. No.134,Wu Kung Road, New Taipei Industrial Park, Wuku District, New Taipei City, Taiwan/新北市五股區新北產業園區五工路134號 台灣檢驗科技股份有限公司 t (886-2) 2299-3279 f (886-2) 2298-0488 www.sgs.com.tw Member of SGS Group Report No.: TERF2211002140ER-P Page: 2 of 9 Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only. 除非另有說明,此報告結果僅對測試之樣品負責,同時此樣品僅保留90天。本報告未經本公司書面許可,不可部份複製。 This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http://www.sgs.com.tw/Terms-and-Conditions and for electronic format documents, subject to Terms and Conditions for Electronic Documents at http://www.sgs.com.tw/Terms-and-Conditions. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. SGS Taiwan Ltd. No.134,Wu Kung Road, New Taipei Industrial Park, Wuku District, New Taipei City, Taiwan/新北市五股區新北產業園區五工路134號 台灣檢驗科技股份有限公司 t (886-2) 2299-3279 f (886-2) 2298-0488 www.sgs.com.tw Member of SGS Group Report No.: TERF2211002140ER-P Page: 3 of 9 Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only. 除非另有說明,此報告結果僅對測試之樣品負責,同時此樣品僅保留90天。本報告未經本公司書面許可,不可部份複製。 This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http://www.sgs.com.tw/Terms-and-Conditions and for electronic format documents, subject to Terms and Conditions for Electronic Documents at http://www.sgs.com.tw/Terms-and-Conditions. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. SGS Taiwan …

Text truncated - open the document above for the full version.

ID Label/Location Info

Back view of EUT

Internal Photos

Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only. 除非另有說明,此報告結果僅對測試之樣品負責,同時此樣品僅保留90天。本報告未經本公司書面許可,不可部份複製。 This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http://www.sgs.com.tw/Terms-and-Conditions and for electronic format documents, subject to Terms and Conditions for Electronic Documents at http://www.sgs.com.tw/Terms-and-Conditions. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under th…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Gus Medina(Director, Product Regulatory Compliance)
[email protected]4696248243Fax: 4696248243

Technical Contact

SGS Taiwan LtdJim Chang
[email protected]+886222993279

134, Wu Kung Road, WuKu Industrial Zone · Taiwan

Non-Technical Contact

SGS Taiwan LtdJim Chang
[email protected]+886222993279

Test Firm

SGS Taiwan Ltd. Central RF LabRyan WANG
[email protected]886222993279

Technical Specifications

#Rule PartsFrequency RangePower Output
115C13.56 MHz - 13.56 MHz-
Confidentiality
Long Term

Other Applications from Harman Professional, Inc.

15.6 inches Touch Panel - FCC ID 2AUHEVARIA-150 - Harman Professional, Inc.
2AUHEVARIA-150

15.6 inches Touch Panel

May 27, 2023

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
2AUHE-BP1064L2

Bluetooth Module

Jul 23, 2022

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
POWERED SUBWOOFER - FCC ID 2AUHEPRX900S - Harman Professional, Inc.
2AUHEPRX900S

POWERED SUBWOOFER

Jun 11, 2022

Equipment Class

DTS - Digital Transmission System
Powered Speaker - FCC ID 2AUHEPRX900 - Harman Professional, Inc.
2AUHEPRX900

Powered Speaker

Jun 11, 2022

Equipment Class

DTS - Digital Transmission System
POWERED SPEAKER W/BLUETOOTH - FCC ID 2AUHEEON700 - Harman Professional, Inc.
2AUHEEON700

POWERED SPEAKER W/BLUETOOTH

Apr 12, 2021

Equipment Class

DTS - Digital Transmission System