FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. JPay Inc./
  3. 2AUJ4JP6MINI

2AUJ4JP6MINITablet for Correctional

JPay Inc.
Tablet for Correctional - FCC ID 2AUJ4JP6MINI - JPay Inc.
Click to zoom

Application Details

Equipment Class
NII - Unlicensed National Information Infrastructure TX
Date of Grant
Aug 19, 2020
Application Purpose
Original Equipment
Date of Application
Aug 18, 2020
Equipment Note
Tablet for Correctional
Frequency Range
5755.00000000 - 5795.00000000
Company
JPay Inc.
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

1 Safety, Warranty & Quick Start Guide Model Number: JP6Mini Read this guide carefully before using your device. Reading before using your tablet 2 Reading first - regulatory information This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: —Reorient or relocate the receiving antenna. —Increase the separation between the equipment and receiver. —Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. —Consult the dealer or an experienced radio/TV technician for help. 3 Device overview Model Description JP6Mini WIFI Android Tablet PC –– 4 Using your device for the first time Charging the tablet You might need to charge the battery before using your device. Insert the DC plug of the power adaptor into the DC port of the tablet pc and plug in the power adaptor to a wall outlet.. Below are battery icons showing different status of the battery. Low battery Fully charged Charging Turning on/off Turn on: Press and hold the Power button until the Android boot on window appears. Turn off: Press and hold the Power button for a few seconds, then tap Power off. Restart: Press and hold the Power button for about 10 seconds to restart. 5 Important safety and handling information Built-in rechargeable battery notice This device contains a Lithium Ion Battery. Caution: The battery used in this device may present a fire or chemical burn hazard if mistreated. Do not disassemble, do not heat above 60 degrees C (140 F), do not crush or puncture the battery, or short external contacts or incinerate. See more information on the Quick Start Guide. Tips for proper care of your tablet battery include: •Don’t overcharge. •Avoid using the tablet when it’s plugged in. •Store your device at the correct (cool) temperature. •Don’t let the battery get all the way to 0% before recharging. •Never use an unauthorized charger. •Avoid physical stress to your tablet. •Turn off your device when charging. Caution about high volume usage Warning: Exposure to loud noise from any source for extended periods of time may affect your hearing. The louder the sound, the less time is required before your hearing could be affected. To protect your hearing: • Limit the amount of time you use headsets or headphones at high volume. • Avoid turning up the volume to block out noisy surroundings. • Turn the volume down if you can’t hear people speaking near you. If you experience hearing discomfort, including the sensation of pressure or fullness in your ears, ringing in your ears or muffled speech, you should stop listening to the device through your headset or headphones and have your hearing checked. To prevent possible hearing damage, do not listen at high volume levels for long periods. 6 Batteries and electrical and electronic equipment marked with the symbol of a crossed-out wheeled bin may not be disposed as unsorted municipal waste. Batteries and waste of electrical and electronic equipment (WEEE) shall be treated separately using the collection framework available to customers for the return, recycling, and treatment of batteries and WEEE. When possible, remove and isolate batteries from WEEE prior to placing WEEE in the waste collection stream. Batteries are to be collected separately using the framework available for the return, recycling, and treatment of batteries and accumulators. Environmental, recycling, and disposal information Important battery and WEEE information **Changes or modifications not expressly approved by JPay. Inc could void the user's authority to operate the equipment FCC ID: 2AUJ4JP6MINI This device complies with Part 15 of FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

Cover Letter(s)

6/1/2020 To Whom It May Concern: I hereby appoint Jessica Camuffo to sign letters and applications for any filings with regulatory agencies on our behalf, and to receive and exchange data between our company, the agents company and the agency in connection with certification for any products that our company owns or manufactures. Sincerely, Hezi Ben Moshe Hezi Ben Moshe Hardware Product Manager JPay

Cover Letter(s)

8/7/2020 Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 Subject: Request for Permanent Confidentiality To whom it may concern: In accordance with 47CFR Section 0.457 and Section 0.459 pertaining to confidential material, we hereby request to hold permanently confidential all information contained within the below identified exhibits/document categories submitted pursuant to radio equipment certification requirements for FCC ID: 2AUJ4JP6MINI 1. Block Diagram 2. Operational Description 3. Schematics 4. Parts List / Tune-Up Procedure The above material contains trade secrets and proprietary information as specified by 47CFR 0.457(d) and technical data, which would customarily be guarded from competitors. The public disclosure of this information might be harmful to our company and provide unjustified benefits to our competitors. Sincerely, Michelle Branum, CKC CS on behalf of applicant, Hezi Ben Moshe, Lead Product Manager JPay, A Securus Technologies Company Tel: 954-862-6900 x 1009 | Cell: 305-978-3061 [email protected]

Cover Letter(s)

8/7/2020 Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 Subject: Power Level Setting To whom it may concern: The RF output power level setting will be locked in firmware on the JP6mini as recorded in the test report. This setting is not user-accessible. Sincerely, Michelle Branum, CKC CS on behalf of applicant, Hezi Ben Moshe, Lead Product Manager JPay, A Securus Technologies Company Tel: 954-862-6900 x 1009 | Cell: 305-978-3061 [email protected]

Cover Letter(s)

10981 Marks Way | Miramar, FL 33025 | www.JPay.com | 954-862-6900 April 28, 2020 To Whom It May Concern: JPay LLC (“JPay”), hereby delegates CKC Certification Services, LLC (“CKC”), power of attorney to act on JPay’s behalf in matters pertaining to the certification of the JP6mini tablet. The actions of CKC, regarding the certification of the JP6mini tablet, shall be considered the actions of JPay. Sincerely, JPay LLC Jessica Camuffo Jessica Camuffo, Esq. General Counsel and Chief Administrative Officer

External Photos

F2P22752 Page 1 of 4 2020-05-11 PHOTOGRAPHS: EXTERNAL Securus Technologies - JP6Mini Order Number: F2P22752 Client: Securus Technologies Model: JP6Mini F2P22752 Page 2 of 4 2020-05-11 Order Number: F2P22752 Client: Securus Technologies Model: JP6Mini F2P22752 Page 3 of 4 2020-05-11 Order Number: F2P22752 Client: Securus Technologies Model: JP6Mini F2P22752 Page 4 of 4 2020-05-11

ID Label/Location Info

FCC ID :2AUJ4JP6MINI This device complies with Part 15 of FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

Internal Photos

F2P22752 Page 1 of 6 2020-07-09 PHOTOGRAPHS: INTERNAL Securus Technologies - JP6Mini Front Order Number: F2P22752 Client: Securus Technologies Model: JP6Mini F2P22752 Page 2 of 6 2020-07-09 Order Number: F2P22752 Client: Securus Technologies Model: JP6Mini F2P22752 Page 3 of 6 2020-07-09 Rear Order Number: F2P22752 Client: Securus Technologies Model: JP6Mini F2P22752 Page 4 of 6 2020-07-09 PCBA Order Number: F2P22752 Client: Securus Technologies Model: JP6Mini F2P22752 Page 5 of 6 2020-07-09 MT6625LN Chip Set (4 in 1 chipset, BT/GPS/WIFI/FM) Order Number: F2P22752 Client: Securus Technologies Model: JP6Mini F2P22752 Page 6 of 6 2020-07-09 SANDISK

RF Exposure Info

© 2020 RF Exposure Lab, LLC This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC. 802 N. Twin Oaks Valley Road, Suite 105 • San Marcos, CA 92069 • U.S.A. TEL (760) 471-2100 • FAX (760) 471-2121 http://www.rfexposurelab.com CERTIFICATE OF COMPLIANCE SAR EVALUATION Securus Technologies Dates of Test: February 13-14, 2020 4000 International Parkway Test Report Number: SAR.20200205 Carrollton, TX 75007 Revision B This wireless mobile and/or portable device has been shown to be compliant for localized specific absorption rate (SAR) for uncontrolled environment/general exposure limits specified in ANSI/IEEE Std. C95.1-1992 and had been tested in accordance with the measurement procedures specified in IEEE 1528-2013 and IEC 62209-2:2010 (See test report). I attest to the accuracy of the data. All measurements were performed by myself or were made under my supervision and are correct to the best of my knowledge and belief. I assume full responsibility for the completeness of these measurements and vouch for the qualifications of all persons taking them. RF Exposure Lab, LLC certifies that no party to this application is subject to a denial of Federal benefits that includes FCC benefits pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 853(a). Jay M. Moulton Vice President Testing Cert. # 2387.01 FCC ID: 2AUJ4JP6S Model(s): JP6S Test Sample: Engineering Unit Same as Production Serial Number: 5 th Article Equipment Type: Wireless Tablet Classification: Portable Transmitter Next to Body TX Frequency Range: 2412 – 2462 MHz; 5180 – 5250 MHz; 5745 – 5825 MHz Frequency Tolerance: ± 2.5 ppm Maximum RF Output: 2450 MHz (b) – 13.20 dBm, 5250 MHz (a) – 16.00 dBm, 5800 MHz (a) – 16.00 dBm Conducted Signal Modulation: DSSS, OFDM Antenna Type: Internal PIFA Antenna Application Type: Certification FCC Rule Parts: Part 2, 15C, 15E KDB Test Methodology: KDB 447498 D01 v06, KDB 248227 v02r02, KDB 616217 D04 v01r02 Maximum SAR Value: 1.36 W/kg Reported Separation Distance: 0 mm Report Number: SAR.20200205 © 2020 RF Exposure Lab, LLC Page 2 of 82 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC. Table of Contents 1. Introduction ........................................................................................................................ 4 SAR Definition [5] ................................................................................................................... 5 2. SAR Measurement Setup ................................................................................................... 6 Robotic System ...................................................................................................................... 6 System Hardware ................................................................................................................... 6 System Electronics ................................................................................................................. 7 Probe Measurement System .................................................................................................. 7 3. Probe and Dipole Calibration .............................................................................................15 4. Phantom & Simulating Tissue Specifications .....................................................................16 Head & Body Simulating Mixture Characterization ................................................................16 5. ANSI/IEEE C95.1 – 1992 RF Exposure Limits [2] ..............................................................17 Uncontrolled Environment .....................................................................................................17 Controlled Environment .........................................................................................................17 6. Measurement Uncertainty .................................................................................................18 7. System Validation..............................................................................................................19 Tissue Verification .................................................................................................................19 Test System Verification ........................................................................................................19 8. SAR Test Data Summary ..................................................................................................20 Procedures Used To Establish Test Signal ...........................................................................20 Device Test Condition ...........................................................................................................20 SAR Data Summary – 2450 MHz Body 802.11b ...................................................................26 SAR Data Summary – 5250 MHz Body 802.11a ...................................................................27 SAR Data Summary – 5800 MHz Body 802.11n ...................................................................28 9. Test Equipment List ...........................................................................................................29 10. Conclusion ....................................................................................................................30 11. References ....................................................................................................................31 Appendix A – System Validation Plots and Data .......................................................................32 A ppendix B – SAR Test Data Plots ...........................................................................................40 Appendix C – SAR Test Setup Photos ......................................................................................44 Appendix D – Probe Calibration Data Sheets ...........................…

Text truncated - open the document above for the full version.

Test Report

090215 Report Number: F2P22752-02E Page 1 of 173 Issue Date: 2020-08-13 F2 Labs 16740 Peters Road Middlefield, Ohio 44062 United States of America www.f2labs.com CERTIFICATION TEST REPORT Manufacturer: Securus Technologies 4000 International Parkway Carrollton, Texas 75007 USA Applicant: Same As Above Product Name: JP6Mini Product Description: 4.3” Lithium Capacitive Touch Tablet for Inmates Power Source: Battery and AC/DC Adaptor Model: JP6Mini FCC ID: 2AUJ4JP6MINI Testing Commenced: 2020-04-13 Testing Ended: 2020-08-13 Summary of Test Results: In Compliance The EUT complies with the EMC requirements when manufactured identically as the unit tested in this report, including any required modifications. Any changes to the design or build of this unit subsequent to this testing may deem it non-compliant. Rule(s): • FCC Part 15 Subpart E – Unlicensed National Information Infrastructure Devices, Section 15.407 General technical requirements • FCC15.207 - Conducted Limits Order Number: F2P22752 Applicant: Securus Technologies Model: JP6Mini 090215 Report Number: F2P22752-02E Page 2 of 173 Issue Date: 2020-08-13 Evaluation Conducted by: Julius Chiller, EMC/Wireless Engineer Report Reviewed by: Ken Littell, Director of EMC & Wireless Operations F2 Labs F2 Labs F2 Labs 26501 Ridge Road 16740 Peters Road 8583 Zionsville Road Damascus, MD 20872 Middlefield, OH 44062 Indianapolis, IN 46268 Ph 301.253.4500 Ph 440.632.5541 Ph 317.610.0611 This test report may be reproduced in full; partial reproduction only may be made with the written consent of F2 Labs. The results in this report apply only to the equipment tested. Order Number: F2P22752 Applicant: Securus Technologies Model: JP6Mini 090215 Report Number: F2P22752-02E Page 3 of 173 Issue Date: 2020-08-13 TABLE OF CONTENTS Section Title Page 1 ADMINISTRATIVE INFORMATION 4 2 SUMMARY OF TEST RESULTS/MODIFICATIONS 7 3 TABLE OF MEASURED RESULTS 8 4 ENGINEERING STATEMENT 10 5 EUT INFORMATION AND DATA 11 6 LIST OF MEASUREMENT INSTRUMENTATION 13 7 OCCUPIED BANDWIDTH 14 UNII 1 UNII 3 8 OUTPUT_POWER 35 UNII 1 UNII 3 9 POWER SPECTRAL DENSITY 46 UNII 1 UNII 3 10 RADIATED SPURIOUS EMISSIONS 57 BAND_EDGES_UNII_1 BAND_EDGES_UNII_3 UNII 1 UNII 3 11 CONDUCTED SPURIOUS EMISSIONS 85 UNII 1 UNII 3 12 VOLTAGE VARIATIONS 144 UNII 1 UNII 3 13 CONDUCTED EMISSIONS 165 14 PHOTOGRAPHS 170 Order Number: F2P22752 Applicant: Securus Technologies Model: JP6Mini 090215 Report Number: F2P22752-02E Page 4 of 173 Issue Date: 2020-08-13 1 ADMINISTRATIVE INFORMATION 1.1 Measurement Location: F2 Labs in Middlefield, Ohio. Site description and attenuation data are on file with the FCC's Sampling and Measurement Branch at the FCC Laboratory in Columbia, MD. 1.2 Measurement Procedure: All measurements were performed according to ANSI C63.10:2013 and recommended FCC procedure of measurement of NII operating under Section 15.407 and in KDB789033. A list of the measurement equipment can be found in Section 6. Order Number: F2P22752 Applicant: Securus Technologies Model: JP6Mini 090215 Report Number: F2P22752-02E Page 5 of 173 Issue Date: 2020-08-13 1.3 Uncertainty Budget: The uncertainty in EMC measurements arises from several factors which affect the results, some associated with environmental conditions in the measurement room, the test equipment being used, and the measurement techniques adopted. The measurement uncertainty budgets detailed below are calculated from the test and calibration data and are expressed with a 95% confidence factor using a coverage factor of k=2. The Uncertainty for a laboratory are referred to as Ulab. For Radiated and Conducted Emissions, the Expanded Uncertainty is compared to the Ucispr values to determine if a specific margin is required to deem compliance. Ulab Ucispr If Ulab is less than or equal to Ucispr, then: • compliance is deemed to occur if no measured disturbance exceeds the disturbance limit; • non-compliance is deemed to occur if any measured disturbance exceeds the disturbance limit. If Ulab is greater than Ucispr in table 1, then: • compliance is deemed to occur if no measured disturbance, increased by (Ulab – Ucispr), exceeds the disturbance limit; • non-compliance is deemed to occur if any measured disturbance, increased by (Ulab – Ucispr), exceeds the disturbance limit. Note: Only measurements listed in the tables above that relate to tests included in this Test Report are applicable. Measurement Range Combined Uncertainty Expanded Uncertainty Radiated Emissions <1 GHz @ 3m 2.54 5.07dB Radiated Emissions <1 GHz @ 10m 2.55 5.09dB Radiated Emissions 1 GHz to 2.7 GHz 1.81 3.62dB Radiated Emissions 2.7 GHz to 18 GHz 1.55 3.10dB AC Power Line Conducted Emissions, 150kHz to 30 MHz 1.38 2.76dB AC Power Line Conducted Emissions, 9kHz to 150kHz 1.66 3.32dB Measurement Range Expanded Uncertainty Radiated Emissions <1 GHz @ 3m 5.2dB Radiated Emissions <1 GHz @ 10m 5.2dB Radiated Emissions 1 GHz to 2.7 GHz Under Consideration Radiated Emissions 2.7 GHz to 18 GHz Under Consideration AC Power Line Conducted Emissions, 150kHz to 30 MHz 3.6dB AC Power Line Conducted Emissions, 9kHz to 150kHz 4.0dB Order Number: F2P22752 Applicant: Securus Technologies Model: JP6Mini 090215 Report Number: F2P22752-02E Page 6 of 173 Issue Date: 2020-08-13 1.4 Document History Document Number Description Issue Date Approved By F2P22752-02E First Issue 2020-08-13 K. Littell Order Number: F2P22752 Applicant: Securus Technologies Model: JP6Mini 090215 Report Number: F2P22752-02E Page 7 of 173 Issue Date: 2020-08-13 2 SUMMARY OF TEST RESULTS Test Name Standard(s) Results Radiated Spurious Emissions CFR 47 Part 15.205 / KDB789033 Complies Occupied Bandwidth CFR 47 Part 15.407(e) / Part 15.209 / KDB789033 Complies Output Power CFR 47 Part 15.407(a)(1)(iv) / Part 15.407(a)(3) / KDB789033 Complies Power Spectral Density CFR 47 Part 15.407(a)(1)(iv) / Part 15.407(a)(3) / KDB789033 Complies Conducted Spurious Emissions CFR 47 Part 15.407(b)(1,4) Complies Voltage Variations CFR 47 Part …

Text truncated - open the document above for the full version.

Test Setup Photos

F2P22752 Page 1 of 4 2020-05-11 PHOTOGRAPHS: TEST SETUP Securus Technologies - JP6Mini Occupied Bandwidth, RF Output Power, Power Spectral Density, Voltage Variations, Conducted Spurious Emissions Order Number: F2P22752 Client: Securus Technologies Model: JP6Mini F2P22752 Page 2 of 4 2020-05-11 Radiated Spurious Emissions, Less Than 30 MHz Order Number: F2P22752 Client: Securus Technologies Model: JP6Mini F2P22752 Page 3 of 4 2020-05-11 Radiated Spurious Emissions, 30 MHz to 1000 MHz Radiated Spurious Emissions above 1 GHz Order Number: F2P22752 Client: Securus Technologies Model: JP6Mini F2P22752 Page 4 of 4 2020-05-11 Conducted Emissions

Contact Information

Applicant

Hezi Ben Moshe(Hardware Product Manager)
[email protected]954-862-6900Fax: NA

Test Firm

F2 LabsWendy Fuster
[email protected]301-253-4500Fax: 301-253-5179

Technical Specifications

#Rule PartsFrequency RangePower Output
415E5.75 GHz - 5.79 GHz29.80 mW
Confidentiality
Long Term
Grant Notes
Output power is conducted. Authorized for stand-alone (non-simultaneous) transmit operation in portable RF Exposure configurations. Body-worn operating configuration(s) are restricted to belt clips, holsters or similar accessories that have no metallic component in the assembly. Device operates with 20 MHz and 40 MHz channel bandwidths. Highest reported SAR value: Body: 1.36 W/kg

Other Applications from JPay Inc.

Tablet for Correctional Use - FCC ID 2AUJ4JP6S - JPay Inc.
2AUJ4JP6S

Tablet for Correctional Use

Feb 19, 2020

Equipment Class

NII - Unlicensed National Information Infrastructure TX