Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Quick Start Guide WIFIGPS/GlonassLTEBLE Getting to know your device Lanyard hole Microphone SOS button Call button Silent mode button Charging contacts LED light LED light Screw holes SOS button Charging contacts Put the SIM card The SIM card is not included in the package. A Nano SIM card is available from the user's local operator. Unscrew the back cover and remove. Insert the SIM card and make sure it’s activated with credits. Put the cover back and tighten the screws. Before installing the SIM card, check if the SIM card has PIN code or not, if yes, please use a cell-phone to remove the card's PIN code. TIP TIP TIP Charging your device There are two ways to charge your device. For the first time use, please fully charge the battery for around 2~3 hours. TIP When the battery level falls below 20% it will send a low battery warning message to people on the contact list via text message or APP. TIP The charging base light will glow when charging and turn solid when fully charged. Place the device on the charging base. Connect the USB cable from charging base to the AC adaptor. 1/ charging base Switching on and off device To turn on the device: press the CALL button for 1 second, all the LEDs will flash rapidly. The device can also be turned on automatically by charging via magnetic USB cable or put it into the docking station. To turn off the device: press and hold the side button and SOS button together for 3 seconds until the LEDs turn off. 1sec. 3sec. What do the lights mean? Green Means Light shows a single flash rapidly every 3 seconds Light shows a double flash rapidly every 3 seconds The device has a stable cellular signal The device is registered to the cellular network Light shows a single flash rapidly every 3 seconds The device has no latest location fix Light shows a double flash rapidly every 3 seconds Light Off The device has latest location fix The device is not fixing the latest location Red ON (solid) Device has been fully charged Red shows a double flash rapidly every 3 seconds BLE connected Red Blinking Quickly Red Off or blinking slowly Battery power is lower than 20% The device is charging Cellular signal indicator--Green Power indicator--Red Positioning indicator--Blue Red Blue Means State Red State Activating an SOS Alarm When you need help, press the SOS button for 3-4 seconds till you hear a voice prompt of activating an SOS alarm. This starts the sequence of “help me!” text message send to your emergency contact numbers followed by the outgoing calls. Press for 3-4 seconds If the device fails to connect to the first number, it will call the second number after delay of 10 seconds. In case the second number fails to be connected as well, the system will connect to the third number etc. 3-4sec. Between each call, it will have 10 seconds delay, during this time, user can stop call sequence or prevent a possible false alarm by pressing the SOS button. The receiver of the call can also stop call sequence by pressing 1 on their mobile phone during two way talking. Use the side buttons +/- to adjust the sound volume during a call. Please remember to program emergency contact numbers. It is not mandatory for all ten authorized numbers to be set, however a minimum of one must always be set. Please be patient during the call sequence. There can be short delays as the alarm calls phones who maybe out of range or delivered to people’s voicemail. Getting a GPS fix To get an initial fix for the GPS features, use outdoors or near a window so the device can get a fix on the satellites. This could take few minutes according to your environment. GPS Making a Phone Call To make a call, press side call button for 3 seconds and you will hear a beep, and then it will dial the second number. To end the call, press the SOS button. 3sec. Put device on charging base more than 30 seconds, and they will be paired automatically via Bluetooth. Silent mode button Double-click this button to turn off voice warnings, double-click the button again to turn on voice warnings. Double-click SOS Dimension: 62mm*47mm*17mm Weight: 53g Battery: Rechargeable, 3.7V, 1000mAh Charging voltage: 5V DC Waterproof: IP67 4 locating technologies: GPS, BLE, WIFI, LBS Specification: Don’t use & store the unit in dusty places. Don’t put the unit in overheated or over cooled places. Clean the unit with a piece of dry cloth. Don’t clean in chemicals, detergent. Don’t disassemble or refit the unit. Using other batteries will cause unwanted situation. Cautions: Please comply with the instructions to extend the unit life: Warning: Keep the IMEI and SIM in confidential, or your privacy may expose. A QI charger provides a quick charging and easy to use. The wireless charging pad is not included in the package. 2/ Wireless Charging FCC Statement 1. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference. (2) This device must accept any interference received, including interference that may cause undesired operation. 2. Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the foll…
Text truncated - open the document above for the full version.
Shenzhen Eview GPS Technology DATE :2020-07-27 Equipment Autorisation Division Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 FCC ID: 2AUMJEV-04-LTE Product Name: Personal Mobile Alarm System Request for Confidentiality Pursuant to Sections 0.457 and 0.459 of the commissions rules, we hereby request that the following documents be held confidential: • Schematics • Block diagram • Operation description • BOM • Tune UP These materials contain trade secrets and proprietary information and are not customarily released to the public. The public disclosure of this information might be harmful to the company and provide unjustified benefits to our competitors. Dated this 2020-7-27 By: Bella Wang Signature Printed Title: CEO On behalf of : Shenzhen Eview GPS Technology Telephone: 86-15899795842
Report No: CCISE200610501 Shenzhen Zhongjian Nanfang Testing Co., Ltd. Project No.:CCISE2006105 No.110~116, Building B, Jinyuan Business Building, Xixiang Road, Bao’an District, Shenzhen, Guangdong, China Tel: +86-755-23118282, Fax: +86-755-23116366Page 43 of 53 8 EUT Constructional Details Report No: CCISE200610501 Shenzhen Zhongjian Nanfang Testing Co., Ltd. Project No.:CCISE2006105 No.110~116, Building B, Jinyuan Business Building, Xixiang Road, Bao’an District, Shenzhen, Guangdong, China Tel: +86-755-23118282, Fax: +86-755-23116366Page 44 of 53 Report No: CCISE200610501 Shenzhen Zhongjian Nanfang Testing Co., Ltd. Project No.:CCISE2006105 No.110~116, Building B, Jinyuan Business Building, Xixiang Road, Bao’an District, Shenzhen, Guangdong, China Tel: +86-755-23118282, Fax: +86-755-23116366Page 45 of 53 Report No: CCISE200610501 Shenzhen Zhongjian Nanfang Testing Co., Ltd. Project No.:CCISE2006105 No.110~116, Building B, Jinyuan Business Building, Xixiang Road, Bao’an District, Shenzhen, Guangdong, China Tel: +86-755-23118282, Fax: +86-755-23116366Page 46 of 53
Label label location 15mmx35mm label location FCC ID: 2AUMJEV-04-LT E Model:EV-04 Product Name:Personal mobile alarm system
Report No: CCISE200610501 Shenzhen Zhongjian Nanfang Testing Co., Ltd. Project No.:CCISE2006105 No.110~116, Building B, Jinyuan Business Building, Xixiang Road, Bao’an District, Shenzhen, Guangdong, China Tel: +86-755-23118282, Fax: +86-755-23116366Page 47 of 53 Report No: CCISE200610501 Shenzhen Zhongjian Nanfang Testing Co., Ltd. Project No.:CCISE2006105 No.110~116, Building B, Jinyuan Business Building, Xixiang Road, Bao’an District, Shenzhen, Guangdong, China Tel: +86-755-23118282, Fax: +86-755-23116366Page 48 of 53 Report No: CCISE200610501 Shenzhen Zhongjian Nanfang Testing Co., Ltd. Project No.:CCISE2006105 No.110~116, Building B, Jinyuan Business Building, Xixiang Road, Bao’an District, Shenzhen, Guangdong, China Tel: +86-755-23118282, Fax: +86-755-23116366Page 49 of 53 Report No: CCISE200610501 Shenzhen Zhongjian Nanfang Testing Co., Ltd. Project No.:CCISE2006105 No.110~116, Building B, Jinyuan Business Building, Xixiang Road, Bao’an District, Shenzhen, Guangdong, China Tel: +86-755-23118282, Fax: +86-755-23116366Page 50 of 53 Report No: CCISE200610501 Shenzhen Zhongjian Nanfang Testing Co., Ltd. Project No.:CCISE2006105 No.110~116, Building B, Jinyuan Business Building, Xixiang Road, Bao’an District, Shenzhen, Guangdong, China Tel: +86-755-23118282, Fax: +86-755-23116366Page 51 of 53 Report No: CCISE200610501 Shenzhen Zhongjian Nanfang Testing Co., Ltd. Project No.:CCISE2006105 No.110~116, Building B, Jinyuan Business Building, Xixiang Road, Bao’an District, Shenzhen, Guangdong, China Tel: +86-755-23118282, Fax: +86-755-23116366Page 52 of 53 Report No: CCISE200610501 Shenzhen Zhongjian Nanfang Testing Co., Ltd. Project No.:CCISE2006105 No.110~116, Building B, Jinyuan Business Building, Xixiang Road, Bao’an District, Shenzhen, Guangdong, China Tel: +86-755-23118282, Fax: +86-755-23116366Page 53 of 53 ------End of report------
Shenzhen Zhongjian Nanfang Testing Co., Ltd. Report No: CCISE200610601V01 Authorized Signature: Bruce Zhang Laboratory Manager This report details the results of the testing carried out on one sample. The results contained in this test report do not relate to other samples of the same product and does not permit the use of the CCIS product certification mark. The manufacturer should ensure that all products in series production are in conformity with the product sample detailed in this report. This report may only be reproduced and distributed in full. If the product in this report is used in any configuration other than that detailed in the report, the manufacturer must ensure the new system complies with all relevant standards. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only. 1 Cover Page FCC SAR REPORT Applicant: SHENZHEN EVIEW GPS TECHNOLOGY Address of Applicant: Rm 201, building 1-A, Nankechuang Yuangu, Dalang, Longhua District, Shenzhen, China Equipment Under Test (EUT) Product Name: Personal Mobile Alarm System Model No.: EV-04 FCC ID: 2AUMJEV-04-LTE Applicable standards: FCC 47 CFR Part 2.1093 Date of Test: 09 Jul., 2020 ~ 07 Aug., 2020 Test Result: Maximum Reported 1-g SAR (W/kg) Front to Face: 0.635 Body: 1.235 Report No: CCISE200610601V01 Shenzhen Zhongjian Nanfang Testing Co., Ltd. Project No.: CCISE2006106 No.110~116, Building B, Jinyuan Business Building, Xixiang Road, Bao’an District, Shenzhen, Guangdong, China Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366, E-mail: [email protected] Page 2 of 194 2 Version Version No. Date Description 00 13 Aug., 2020 Original 01 14 Aug., 2020 1. Added 100%RB Body SAR of LTE Band 4 on page 58/121. Tested by: Date: 14 Aug., 2020 Report Clerk Reviewed by: Date: 14 Aug., 2020 Project Engineer Report No: CCISE200610601V01 Shenzhen Zhongjian Nanfang Testing Co., Ltd. Project No.: CCISE2006106 No.110~116, Building B, Jinyuan Business Building, Xixiang Road, Bao’an District, Shenzhen, Guangdong, China Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366, E-mail: [email protected] Page 3 of 194 3 Contents 1 COVER PAGE ....................................................................................................................................................... 1 2 VERSION ............................................................................................................................................................... 2 3 CONTENTS ........................................................................................................................................................... 3 4 SAR RESULTS SUMMARY ................................................................................................................................. 5 5 GENERAL INFORMATION .................................................................................................................................. 6 5.1 CLIENT INFORMATION ..................................................................................................................................................................... 6 5.2 GENERAL DESCRIPTION OF EUT ................................................................................................................................................... 6 5.3 MAXIMUM RF OUTPUT POWER ...................................................................................................................................................... 7 5.4 ENVIRONMENT OF TEST SITE ......................................................................................................................................................... 8 5.5 TEST SAMPLE PLAN ....................................................................................................................................................................... 8 5.6 TEST LOCATION ............................................................................................................................................................................. 8 6 INTRODUCTION ................................................................................................................................................... 9 6.1 INTRODUCTION ............................................................................................................................................................................... 9 6.2 SAR DEFINITION ............................................................................................................................................................................ 9 7 RF EXPOSURE LIMITS ..................................................................................................................................... 10 7.1 UNCONTROLLED ENVIRONMENT ................................................................................................................................................... 10 7.2 CONTROLLED ENVIRONMENT ....................................................................................................................................................... 10 7.3 RF EXPOSURE LIMITS .................................................................................................................................................................. 10 8 SAR MEASUREMENT SYSTEM ....................................................................................................................... 11 8.1 E-FIELD PROBE.................................................................................................................................................................…
Text truncated - open the document above for the full version.
Report No: CCISE200610601V01 Shenzhen Zhongjian Nanfang Testing Co., Ltd. Project No.: CCISE2006106 No.110~116, Building B, Jinyuan Business Building, Xixiang Road, Bao’an District, Shenzhen, Guangdong, China Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366, E-mail: [email protected] Page 101 of 194 Test Laboratory: CCIS Date/Time: 07.12.2020 11:49:22 DUT: Personal Mobile Alarm System; Type: EV-04; Serial: 1# Communication System: UID 0, LTE-FDD (USA) 10MHz 50%RB QPSK (0); Frequency: 782 MHz; Duty Cycle: 1:1 Medium parameters used (interpolated): f = 782 MHz; σ = 0.873 S/m; ε r = 41.458; ρ = 1000 kg/m 3 Phantom section: Flat Section DASY5 Configuration: Probe: EX3DV4 - SN3924; ConvF(10.07, 10.07, 10.07); Calibrated: 08.30.2019; Sensor-Surface: 1.4mm (Mechanical Surface Detection) Electronics: DAE4 Sn1373; Calibrated: 08.09.2019 Phantom: SAM 5.0; Type: QD000P40CD; Serial: TP:1765 Measurement SW: DASY52, Version 52.8 (8); SEMCAD X Version 14.6.10 (7331) LTE Band 13 50%RB(10MHz) Front to Face/Middle Channel/Area Scan (41x51x1): Interpolated grid: dx=1.500 mm, dy=1.500 mm Maximum value of SAR (interpolated) = 0.194 W/kg LTE Band 13 50%RB(10MHz) Front to Face/Middle Channel/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 11.78 V/m; Power Drift = 0.08 dB Peak SAR (extrapolated) = 0.232 W/kg SAR(1 g) = 0.144 W/kg; SAR(10 g) = 0.091 W/kg Maximum value of SAR (measured) = 0.200 W/kg 0 dB = 0.200 W/kg = -6.99 dBW/kg Report No: CCISE200610601V01 Shenzhen Zhongjian Nanfang Testing Co., Ltd. Project No.: CCISE2006106 No.110~116, Building B, Jinyuan Business Building, Xixiang Road, Bao’an District, Shenzhen, Guangdong, China Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366, E-mail: [email protected] Page 102 of 194 Test Laboratory: CCIS Date/Time: 07.17.2020 16:42:03 DUT: Personal Mobile Alarm System; Type: EV-04; Serial: 1# Communication System: UID 0, IEEE 802.11b WiFi 2.4 GHz (DSSS, 1 Mbps) (0); Frequency: 2412 MHz; Duty Cycle: 1:1 Medium parameters used (interpolated): f = 2412 MHz; σ = 1.807 S/m; ε r = 39.574; ρ = 1000 kg/m 3 Phantom section: Flat Section DASY5 Configuration: Probe: EX3DV4 - SN3924; ConvF(7.54, 7.54, 7.54); Calibrated: 08.30.2019; Sensor-Surface: 1.4mm (Mechanical Surface Detection) Electronics: DAE4 Sn1373; Calibrated: 08.09.2019 Phantom: SAM 5.0; Type: QD000P40CD; Serial: TP:1765 Measurement SW: DASY52, Version 52.8 (8); SEMCAD X Version 14.6.10 (7331) WIFI Front to Face/Low Channel/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Reference Value = 9.201 V/m; Power Drift = -0.09 dB Peak SAR (extrapolated) = 0.185 W/kg SAR(1 g) = 0.100 W/kg; SAR(10 g) = 0.056 W/kg Maximum value of SAR (measured) = 0.152 W/kg WIFI Front to Face/Low Channel/Area Scan (41x51x1): Interpolated grid: dx=1.200 mm, dy=1.200 mm Maximum value of SAR (interpolated) = 0.185 W/kg 0 dB = 0.185 W/kg = -7.33 dBW/kg Report No: CCISE200610601V01 Shenzhen Zhongjian Nanfang Testing Co., Ltd. Project No.: CCISE2006106 No.110~116, Building B, Jinyuan Business Building, Xixiang Road, Bao’an District, Shenzhen, Guangdong, China Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366, E-mail: [email protected] Page 103 of 194 Test Laboratory: CCIS Date/Time: 08.07.2020 9:01:16 DUT: Personal Mobile Alarm System; Type: EV-04; Serial: 1# Communication System: UID 0, GPRS(4 Slots) (0); Frequency: 824.2 MHz; Duty Cycle: 1:1.99986 Medium parameters used (interpolated): f = 824.2 MHz; σ = 0.975 S/m; ε r = 54.279; ρ = 1000 kg/m 3 Phantom section: Flat Section DASY5 Configuration: Probe: EX3DV4 - SN3924; ConvF(9.72, 9.72, 9.72); Calibrated: 08.30.2019; Sensor-Surface: 1.4mm (Mechanical Surface Detection) Electronics: DAE4 Sn1373; Calibrated: 08.09.2019 Phantom: ELI v5.0; Type: QDOVA002AA; Serial: TP:1208 Measurement SW: DASY52, Version 52.8 (8); SEMCAD X Version 14.6.10 (7331) GPRS 850 4Slots Body Back/Low Channel/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 18.75 V/m; Power Drift = -0.12 dB Peak SAR (extrapolated) = 0.862 W/kg SAR(1 g) = 0.404 W/kg; SAR(10 g) = 0.229 W/kg Maximum value of SAR (measured) = 0.668 W/kg GPRS 850 4Slots Body Back/Low Channel/Area Scan (41x51x1): Interpolated grid: dx=1.500 mm, dy=1.500 mm Maximum value of SAR (interpolated) = 0.760 W/kg 0 dB = 0.760 W/kg = -1.19 dBW/kg Report No: CCISE200610601V01 Shenzhen Zhongjian Nanfang Testing Co., Ltd. Project No.: CCISE2006106 No.110~116, Building B, Jinyuan Business Building, Xixiang Road, Bao’an District, Shenzhen, Guangdong, China Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366, E-mail: [email protected] Page 104 of 194 Test Laboratory: CCIS Date/Time: 07.30.2020 9:19:16 DUT: Personal Mobile Alarm System; Type: EV-04; Serial: 1# Communication System: UID 0, GPRS(4 Slots) (0); Frequency: 1909.8 MHz; Duty Cycle: 1:1.99986 Medium parameters used: f = 1909.8 MHz; σ = 1.523 S/m; ε r = 53.104; ρ = 1000 kg/m 3 Phantom section: Flat Section DASY5 Configuration: Probe: EX3DV4 - SN3924; ConvF(7.83, 7.83, 7.83); Calibrated: 08.30.2019; Sensor-Surface: 1.4mm (Mechanical Surface Detection) Electronics: DAE4 Sn1373; Calibrated: 08.09.2019 Phantom: ELI v5.0; Type: QDOVA002AA; Serial: TP:1208 Measurement SW: DASY52, Version 52.8 (8); SEMCAD X Version 14.6.10 (7331) GPRS 1900 4Slots Body Back/High Channel/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 21.35 V/m; Power Drift = -0.10 dB Peak SAR (extrapolated) = 1.19 W/kg SAR(1 g) = 0.696 W/kg; SAR(10 g) = 0.391 W/kg Maximum value of SAR (measured) = 0.993 W/kg GPRS 1900 4Slots Body Back/High Channel/Area Scan (41x51x1): Interpolated grid: dx=1.500 mm, dy=1.500 mm Maximum value of SAR (interpolated) = 1.12 W/kg 0 dB = 1.12 W/kg = 0.49 dBW/kg Report No: CCISE200610601V01 Shenzhen Zhongjian Nanfang Testing Co., Ltd. Project No.: CCISE2006106 No.110~116, Building B, Jinyuan Business Building, Xixiang Road, Bao’an District, Shenzhen,…
Text truncated - open the document above for the full version.
EUT Photos (Model: EV-04) EUT Antenna Locations SAR Test Setup Photos Head Front to Face (10mm) Body Front side (5mm) Back side(5mm) Top side(5mm) Bottom side(5mm) Left side(5mm) Right side(5mm)
Shenzhen ZhongjianNanfang Testing Co., Ltd. Report No:CCISE200610502 Authorized Signature: Bruce Zhang Laboratory Manager This report details the results of the testing carried out on one sample. The results contained in this test report do not relate to other samples of the same product and does not permit the use of theCCISproduct certification mark. The manufacturer should ensure that all products in series production are in conformity with the product sample detailed in this report. This report may only be reproduced and distributed in full. If the product in this report is used in any configuration other than that detailed in the report, the manufacturer must ensure the new system complies with all relevant standards. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery orfalsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only. 1 Cover Page FCC REPORT (BLE) Applicant: SHENZHEN EVIEW GPS TECHNOLOGY Address of Applicant: Rm 201, building 1-A, NankechuangYuangu, Dalang, Longhua District, Shenzhen, China Equipment Under Test (EUT) Product Name: Personal Mobile Alarm System Model No.: EV-04 FCC ID: 2AUMJEV-04-LTE Applicable standards: FCC CFR Title 47 Part 15 Subpart C Section 15.247 Date of sample receipt: 28 Jun., 2020 Date of Test: 29 Jun., to 30 Jul., 2020 Date of report issued: 31 Jul., 2020 Test Result: PASS * * In the configuration tested, the EUT complied with the standards specified above. Report No: CCISE200610502 Shenzhen ZhongjianNanfang Testing Co., Ltd. Project No.:CCISE2006105 No.110~116,Building B, Jinyuan Business Building, Xixiang Road, Bao’an District, Shenzhen, Guangdong, China Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366 Page 2 of 34 2 Version Version No. Date Description 00 31 Jul., 2020 Original Tested by: Date: 31 Jul., 2020 Test Engineer Reviewed by: Date: 31 Jul., 2020 Project Engineer Report No: CCISE200610502 Shenzhen ZhongjianNanfang Testing Co., Ltd. Project No.:CCISE2006105 No.110~116,Building B, Jinyuan Business Building, Xixiang Road, Bao’an District, Shenzhen, Guangdong, China Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366 Page 3 of 34 3 Contents Page 1 COVER PAGE ....................................................................................................................................................... 1 2 VERSION ............................................................................................................................................................... 2 3 CONTENTS ........................................................................................................................................................... 3 4 TEST SUMMARY .................................................................................................................................................. 4 5 GENERAL INFORMATION .................................................................................................................................. 5 5.1 CLIENT INFORMATION ............................................................................................................................................ 5 5.2 GENERAL DESCRIPTION OF E.U.T. ....................................................................................................................... 5 5.3 TEST ENVIRONMENT AND MODE, AND TEST SAMPLES PLANS ............................................................................... 6 5.4 DESCRIPTION OF SUPPORT UNITS ........................................................................................................................ 6 5.5 MEASUREMENT UNCERTAINTY .............................................................................................................................. 6 5.6 ADDITIONS TO, DEVIATIONS, OR EXCLUSIONS FROM THE METHOD....................................................................... 6 5.7 LABORATORY FACILITY .......................................................................................................................................... 6 5.8 LABORATORY LOCATION ....................................................................................................................................... 6 5.9 TEST INSTRUMENTS LIST ....................................................................................................................................... 7 6 TEST RESULTS AND MEASUREMENT DATA ................................................................................................ 8 6.1 ANTENNA REQUIREMENT: ...................................................................................................................................... 8 6.2 CONDUCTED EMISSION ......................................................................................................................................... 9 6.3 CONDUCTED OUTPUT POWER ............................................................................................................................ 12 6.4 OCCUPY BANDWIDTH .......................................................................................................................................... 14 6.5 POWER SPECTRAL DENSITY ............................................................................................................................... 16 6.6 BAND EDGE ......................................................................................................................................................... 18 6.6.1 Conducted Emission Method...................................................................................................................... 18 6.6.2 Radiated Emission Method ...............................…
Text truncated - open the document above for the full version.
Shenzhen ZhongjianNanfang Testing Co., Ltd. Report No:CCISE200610504 Authorized Signature: Bruce Zhang Laboratory Manager This report details the results of the testing carried out on one sample. The results contained in this test report do not relate to other samples of the same product and does not permit the use of theCCISproduct certification mark. The manufacturer should ensure that all products in series production are in conformity with the product sample detailed in this report. This report may only be reproduced and distributed in full. If the product in this report is used in any configuration other than that detailed in the report, the manufacturer must ensure the new system complies with all relevant standards. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery orfalsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only. 1 Cover Page FCC REPORT (WIFI) Applicant: SHENZHEN EVIEW GPS TECHNOLOGY Address of Applicant: Rm 201, building 1-A, NankechuangYuangu, Dalang, Longhua District, Shenzhen, China Equipment Under Test (EUT) Product Name: Personal Mobile Alarm System Model No.: EV-04 FCC ID: 2AUMJEV-04-LTE Applicable standards: FCC CFR Title 47 Part 15 Subpart C Section 15.247 Date of sample receipt: 28 Jun., 2020 Date of Test: 29 Jun., to 30 Jul., 2020 Date of report issued: 31 Jul., 2020 Test Result: PASS* * In the configuration tested, the EUT complied with the standards specified above. Report No: CCISE200610504 Shenzhen ZhongjianNanfang Testing Co., Ltd. Project No.:CCISE2006105 No.110~116,Building B, Jinyuan Business Building, Xixiang Road, Bao’an District, Sh…
Text truncated - open the document above for the full version.
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 2 | 15C | 2.40 GHz - 2.48 GHz | 2.63 mW |
Personal Mobile Alarm System
Equipment Class
DTS - Digital Transmission SystemPersonal Mobile Alarm System
Equipment Class
DTS - Digital Transmission SystemPersonal Mobile Alarm System
Equipment Class
DTS - Digital Transmission SystemCharging base
Equipment Class
DXX - Part 15 Low Power Communication Device TransmitterPersonal Mobile Alarm System
Equipment Class
PCB - PCS Licensed Transmitter