FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Robert Bosch GmbH/
  3. 2AUXS-10INCOLORD

2AUXS-10INCOLORDInstrument cluster with Bluetooth & WiFi for operation in a vehicle

Robert Bosch GmbH

Application Details

Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Date of Grant
Jun 01, 2026
Application Purpose
Original Equipment
Equipment Note
Instrument cluster with Bluetooth & WiFi for operation in a vehicle
Frequency Range
2402.00000000 - 2480.00000000
Company
Robert Bosch GmbH
Country
Germany

Documents & Files

Select a file to view

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗
↗

ID Label/Location Info

↗

RF Exposure Info

↗

Test Report

↗
↗
↗
↗
↗
↗
↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Attestation Statements

Registered Office: Stuttgart, Registration Court: Amtsgericht Stuttgart, HRB 14000; Chairman of the Supervisory Board: Prof. Dr. Stefan Asenkerschbaumer; Managing Directors: Dr. Stefan Hartung, Dr. Christian Fischer, Dr. Markus Forschner, Stefan Grosch, Dr. Markus Heyn, Dr. Frank Meyer, Katja von Raven, Dr. Tanja Rückert Robert Bosch GmbH Postfach 10 02 61 31102 Hildesheim Visitor: Robert-Bosch-Straße 200 31139 Hildesheim Phone +49 5121 49-0 www.bosch.com Yasin Chaar, XC/QMM-VR2.1 Phone +49 5121 49-6836 [email protected] Certifications concerning “covered” equipment. Section 2.911(d)(5)(i)- (ii) May 13, 2026 FCC ID: 2AUXS-10INCOLORD To whom it may concern: we, Robert Bosch GmbH, Robert-Bosch-Strasse 200, 31139 Hildesheim, Germany, certify that: - the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules; - as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. Also, we certify that the equipment for which authorization is sought does not contain or includes equipment with integrated cybersecurity and anti-virus software produced or provided by Kaspersky Lab, Inc. or any of its successors and assignees. Yours sincerely Robert Bosch GmbH Dirk Zamow Group Manager DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía C/ Severo Ochoa 2 & 6 29590 Campanillas Málaga, España

Attestation Statements

Registered Office: Stuttgart, Registration Court: Amtsgericht Stuttgart, HRB 14000; Chairman of the Supervisory Board: Prof. Dr. Stefan Asenkerschbaumer; Managing Directors: Dr. Stefan Hartung, Dr. Christian Fischer, Dr. Markus Forschner, Stefan Grosch, Dr. Markus Heyn, Dr. Frank Meyer, Katja von Raven, Dr. Tanja Rückert Robert Bosch GmbH Postfach 10 02 61 31102 Hildesheim Visitor: Robert-Bosch-Straße 200 31139 Hildesheim Phone +49 5121 49-0 www.bosch.com Yasin Chaar, XC/QMM-VR2.1 Phone +49 5121 49-6836 [email protected] Certification designating a U.S. agent for service of process. As required by section 2.911(d)(7) May 08, 2026 FCC ID: 2AUXS-10INCOLORD To whom it may concern: We, Robert Bosch GmbH, Robert-Bosch-Strasse 200, 31139 Hildesheim, Germany, FRN: 0029579075, Certify that: Wiley Rein LLP, 2050 M Street, NW, Washington, DC 20036, FRN: 0035942069, Sara Baxenberg, [email protected], is our designated U.S. agent for service of process and we acknowledge: - our consent to accept service of process in the United States for matters related to the applicable equipment at the physical U.S. address and email address of the designated U.S. agent; - the acceptance to maintain an U.S. agent for no less than one year after the grantee has terminated all marketing and importation or the DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía C/ Severo Ochoa 2 & 6 29590 Campanillas Málaga, España May 08, 2026 Page 2 of 2 conclusion of any Commission-related proceeding involving the equipment. Applicant Designated U.S. Agent Sincerely, __________________________ By: Dirk Zamow Title: Group Manager Company: Robert Bosch GmbH Telephone: +49 5121 / 49-2608 e-mail: [email protected] We acknowledge our obligation to accept service of process in the United States for matters related to the applicable equipment at our physical U.S. address and email address stated above. __________________________ By: Sara Baxenberg Title: Partner Company: Wiley Rein LLP Telephone: (202) 719-7000 3755 e-mail: [email protected] Yours sincerely Robert Bosch GmbH Dirk Zamow Group Manager

Cover Letter(s)

Registered Office: Stuttgart, Registration Court: Amtsgericht Stuttgart, HRB 14000; Chairman of the Supervisory Board: Prof. Dr. Stefan Asenkerschbaumer; Managing Directors: Dr. Stefan Hartung, Dr. Christian Fischer, Dr. Markus Forschner, Stefan Grosch, Dr. Markus Heyn, Dr. Frank Meyer, Katja von Raven, Dr. Tanja Rückert Robert Bosch GmbH Postfach 10 02 61 31102 Hildesheim Visitor: Robert-Bosch-Straße 200 31139 Hildesheim Phone +49 5121 49-0 www.bosch.com Yasin Chaar, XC/QMM-VR2.1 Phone +49 5121 49-6836 [email protected] FCC Agent letter May 13, 2026 FCC ID: 2AUXS-10INCOLORD To whom it may concern: we, Robert Bosch GmbH, Robert-Bosch-Strasse 200, 31139 Hildesheim, Germany, hereby authorize: DEKRA Testing and Certification, S.A.U., C/Severo Ochoa, 2 & 6, 29590, Málaga, Spain, Mr. Ricardo Arrabal, e-mail: [email protected], Phone: +34 952 619 846, to act as our agent in the preparation of this application for equipment certification, including the signing of all documents relating to these matters. The present authorization considers the development of documents on behalf of the client, written under his own letterhead and related to the necessary information to be provided on his behalf to complete the certification process. DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía C/ Severo Ochoa 2 & 6 29590 Campanillas Málaga, España May 13, 2026 Page 2 of 2 We also hereby certify that neither we nor any party to this application are subject to a denial of U.S. Federal benefits, which include FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, U.S.C. 862 because of conviction for possession or distribution of controlled substance. For instances where our authorized agent signs the application for certification on our behalf, I acknowledge that all responsibility for complying with the terms and conditions for Certification, as specified by DEKRA Testing and Certification, S.A.U., still resides with us. This agreement expires one year from the current date. Yours sincerely Robert Bosch GmbH Dirk Zamow Group Manager Telephone: +49 5121 / 49-2608 e-mail: [email protected]

Cover Letter(s)

Registered Office: Stuttgart, Registration Court: Amtsgericht Stuttgart, HRB 14000; Chairman of the Supervisory Board: Prof. Dr. Stefan Asenkerschbaumer; Managing Directors: Dr. Stefan Hartung, Dr. Christian Fischer, Dr. Markus Forschner, Stefan Grosch, Dr. Markus Heyn, Dr. Frank Meyer, Katja von Raven, Dr. Tanja Rückert Robert Bosch GmbH Postfach 10 02 61 31102 Hildesheim Visitor: Robert-Bosch-Straße 200 31139 Hildesheim Phone +49 5121 49-0 www.bosch.com Tilman Almstedt, XC/QMM-VR2.1 Phone +49 5121 49-4226 [email protected] FCC Confidentiality request May 29, 2026 FCC ID: 2AUXS-10INCOLORD To whom it may concern: pursuant to §0.457(d)(1)(ii) and §0.459 of the Commission’s Rules (47 C.F.R.) and §552 (b)(4) of the Freedom of Information Act, we, Robert Bosch GmbH, Robert-Bosch-Strasse 200, 31139 Hildesheim, Germany, hereby requests that a part of the subject FCC application be held confidential to avoid release of sensitive information of the product to the public. For the product stated above, we request that the following information be withheld from public disclose: Type of Confidentiality Requested Exhibit Short Term Permanent Block Diagrams Short Term External Photos Short Term Internal Photos Short Term Permanent Operation Description Short Term Permanent Parts List & Placement/BOM Short Term Permanent Tune-Up Procedure Short Term Permanent Schematics Short Term Test Setup Photos Short Term User’s Manual DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía C/ Severo Ochoa 2 & 6 29590 Campanillas Málaga, España May 29, 2026 Page 2 of 2 Short Term Permanent SDR software and security information Permanent Confidentiality: The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these matters might be harmful to us and provide unjustified benefits to our competitors. Short-Term Confidentiality: We hereby request short-term confidentiality for the product stated above to avoid premature release of sensitive information prior to marketing or release of the product to the public. Release date of short-term confidentiality is: 45 days from grant date marked 90 days from grant date marked 135 days from grant date marked 180 days from grant date marked Specific date: We are also aware that we are responsible to notify DEKRA in the event information regarding the product or the product is made available to the public. DEKRA will then release the documents listed above for public disclosure pursuant to FCC Public Notice DA 04-1705. Yours sincerely Robert Bosch GmbH Dirk Zamow Group Manager Telephone: +49 5121 / 49-2608 e-mail: [email protected]

Cover Letter(s)

Registered Office: Stuttgart, Registration Court: Amtsgericht Stuttgart, HRB 14000; Chairman of the Supervisory Board: Prof. Dr. Stefan Asenkerschbaumer; Managing Directors: Dr. Stefan Hartung, Dr. Christian Fischer, Dr. Markus Forschner, Stefan Grosch, Dr. Markus Heyn, Dr. Frank Meyer, Katja von Raven, Dr. Tanja Rückert Robert Bosch GmbH Postfach 10 02 61 31102 Hildesheim Visitor: Robert-Bosch-Straße 200 31139 Hildesheim Phone +49 5121 49-0 www.bosch.com Yasin Chaar, XC/QMM-VR2.1 Phone +49 5121 49-6836 [email protected] FCC sDoC declaration letter May 13, 2026 FCC ID: 2AUXS-10INCOLORD To whom it may concern: pursuant to §15.101 of the Commission’s Rules (47 C.F.R.), we, Robert Bosch GmbH, Robert-Bosch-Strasse 200, 31139 Hildesheim, Germany, hereby declare that the device above mentioned is classified under the following equipment class/classes: JAB Part 15 Class B Digital Device JAD Part 15 Class A Digital Device JAV Other Non-Digital SDoC Devices JBP Part 15 Class B Computing Device/Personal Computer JBC Part 15 Class B Computing Device/Personal Computer CXX Communications Rcvr for use w/ licensed Tx and CBs CRR Superregenerative Receiver CYY Communications Receiver used w/Pt 15 Transmitter HID Part 15 TV Interface Device DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía C/ Severo Ochoa 2 & 6 29590 Campanillas Málaga, España May 13, 2026 Page 2 of 2 and will follow the Authorization procedure Supplier’s Declaration of Conformity prior to the initiation of marketing. Yours sincerely Robert Bosch GmbH Dirk Zamow Group Manager Telephone: +49 5121 / 49-2608 e-mail: [email protected]

RF Exposure Info

DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía, c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España C.I.F. A29 507 456 Report No: (NIE) 85236RAN.002A1 2026-05-29 Test report No: NIE: 85236RAN.002A1 Assessment report RF EXPOSURE REPORT ACCORDING TO FCC 47 CFR Part 2.1091; FCC 47 CFR Part 1.1307 FCC 47 CFR Part 1.1310 (*) Identification of item under evaluation An instrument cluster with Bluetooth® & WIFI for operation in a vehicle. (*) Trademark BOSCH (*) Model and /or type reference 10inColorD (*) Other identification of the product FCC ID: 2AUXS-10INCOLORD IC ID: 25847-10INCOLORD HW version: C4.0 SW version: BRP10-0.0.SWP25.5.951 (*) Features Bluetooth, Bluetooth LE, 802.11@2,4GHz, 802.11@5GHz (*) Manufacturer Robert Bosch GmbH Robert-Bosch-Platz 1, 70839 Gerlingen, Germany Test method requested, standard FCC 47 CFR Part 2.1091 Radiofrequency radiation exposure evaluation: mobile devices. FCC 47 CFR Part 1.1307: Actions that may have a significant environmental effect, for which Environmental Assessments (EAs) must be prepared. FCC 47 CFR Part 1.1310: Radiofrequency radiation exposure limits. Summary IN COMPLIANCE Approved by (name / position & signature) Manuel García Antennas Lab Technical Responsible Date of issue 2026-05-29 Report template No FAN36_03 (*) “Data provided by the client” DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía, c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España C.I.F. A29 507 456 Report No: (NIE) 85236RAN.002A1 Page 2 of 10 2026-05-29 Index Competences and guarantees .................................................................................................... 3 General conditions ...................................................................................................................... 3 Data provided by the client .......................................................................................................... 3 Identification of the client............................................................................................................. 3 Document history ........................................................................................................................ 3 Appendix A: FCC RF Exposure assessment result ..................................................................... 4 General description of the device under evaluation ................................................................ 5 Evaluation Results .................................................................................................................. 6 Appendix B: FCC RF Exposure information ................................................................................ 7 RF Exposure determination of exemption ............................................................................... 8 RF Exposure evaluation ....................................................................................................... 10 DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía, c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España C.I.F. A29 507 456 Report No: (NIE) 85236RAN.002A1 Page 3 of 10 2026-05-29 Competences and guarantees In order to assure the traceability to other national and international laboratories, DEKRA Testing and Certification, S.A.U. has a calibration and maintenance program for its measurement equipment. DEKRA Testing and Certification, S.A.U. guarantees the reliability of the data presented in this report, which is the result of the measurements and the tests performed to the item under test on the date and under the conditions stated on the report and, it is based on the knowledge and technical facilities available at DEKRA Testing and Certification, S.A.U. at the time of performance of the test. DEKRA Testing and Certification, S.A.U. is liable to the client for the maintenance of the confidentiality of all information related to the item under test and the results of the test. The results presented in this Assessment Report apply only to the particular item under test established in this document. IMPORTANT: No parts of this report may be reproduced or quoted out of context, in any form or by any means, except in full, without the previous written permission of DEKRA Testing and Certification, S.A.U. General conditions 1. This report is only referred to the item that has undergone the assessment. 2. This report does not constitute or imply on its own an approval of the product by the Certification Bodies or competent Authorities. 3. This document is only valid if complete; no partial reproduction can be made without previous written permission of DEKRA Testing and Certification, S.A.U. 4. This assessment report cannot be used partially or in full for publicity and/or promotional purposes without previous written permission of DEKRA Testing and Certification, S.A.U. Data provided by the client The following data has been provided by the client: 1. Information relating to the description of the sample ("Identification of the item under evaluation", "Trademark", "Model and/or type reference", “General description of the device”, “Other identification of the product”). 2. Maximum output power, maximum antenna gain and use distance information. 3. The device under evaluation consists of an instrument cluster with Bluetooth® & Wi-Fi for operation in a vehicle. DEKRA Testing and Certification S.A.U. declines any responsibility with respect to the information provided by the client and that may affect the validity of results. Identification of the client Robert Bosch GmbH Robert-Bosch-Platz 1, 70839 Gerlingen, Germany Document history Report number Date Description 85236RAN.002 2026-05-28 First release 85236RAN.002A1 2026-05-29 Second release Bluetooth conducted output power have been updated. This test report cancels and replaces 85236RAN.002 DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía, c/ Severo Ochoa nº 2 …

Text truncated - open the document above for the full version.

Test Report

DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía, c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España C.I.F. A29507456 Report No: 85236RRF.001A1 Page 143 of 427 2026-05-29 DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía, c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España C.I.F. A29507456 Report No: 85236RRF.001A1 Page 144 of 427 2026-05-29 Operation Band MHz = [2400, 2483.5] Equipment Type = Frequency Hopping Spread Spectrum systems (DSS) Frequency MHz = 2480.00000 Active Port = 1 Modulation = BT (Pi/4 DQPSK 2- DH5) Images: Level in dBm DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía, c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España C.I.F. A29507456 Report No: 85236RRF.001A1 Page 145 of 427 2026-05-29 DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía, c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España C.I.F. A29507456 Report No: 85236RRF.001A1 Page 146 of 427 2026-05-29 Modulation: BT (8DPSK 3-DH5) Results Radiated measurements were used to show compliance with the limits in the restricted bands 2.31-2.39 GHz and 2.4835-2.5 GHz. Verdict Pass DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía, c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España C.I.F. A29507456 Report No: 85236RRF.001A1 Page 147 of 427 2026-05-29 Attachments Operation Band MHz = [2400, 2483.5] Equipment Type = Frequency Hopping Spread Spectrum systems (DSS) Modulation = BT (8DPSK 3-DH5) Active Port = 1 Images: Level in dBm DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía, c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España C.I.F. A29507456 Report No: 85236RRF.001A1 Page 148 of 427 2026-05-29 DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía, c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España C.I.F. A29507456 Report No: 85236RRF.001A1 Page 149 of 427 2026-05-29 Operation Band MHz = [2400, 2483.5] Equipment Type = Frequency Hopping Spread Spectrum systems (DSS) Modulation = BT (8DPSK 3-DH5) Active Port = 1 Images: Level in dBm DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía, c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España C.I.F. A29507456 Report No: 85236RRF.001A1 Page 150 of 427 2026-05-29 DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía, c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España C.I.F. A29507456 Report No: 85236RRF.001A1 Page 151 of 427 2026-05-29 Operation Band MHz = [2400, 2483.5] Equipment Type = Frequency Hopping Spread Spectrum systems (DSS) Frequency MHz = 2402.00000 Active Port = 1 Modulation = BT (8DPSK 3-DH5) Images: Level in dBm DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía, c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España C.I.F. A29507456 Report No: 85236RRF.001A1 Page 152 of 427 2026-05-29 DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía, c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España C.I.F. A29507456 Report No: 85236RRF.001A1 Page 153 of 427 2026-05-29 Operation Band MHz = [2400, 2483.5] Equipment Type = Frequency Hopping Spread Spectrum systems (DSS) Frequency MHz = 2480.00000 Active Port = 1 Modulation = BT (8DPSK 3-DH5) Images: Level in dBm DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía, c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España C.I.F. A29507456 Report No: 85236RRF.001A1 Page 154 of 427 2026-05-29 DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía, c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España C.I.F. A29507456 Report No: 85236RRF.001A1 Page 155 of 427 2026-05-29 RSS-247 6.6 / FCC 15.247 (d) Emission limitations radiated (Transmitter) Limits Radiated emissions which fall in the restricted bands, as defined in Section 15.205(a), must also comply with the radiated emission limits specified in Section 15.209(a) (see Section 15.205(c)/RSS-Gen): Frequency Range (MHz) Field strength (μV/m) Field strength (dBμV/m) Measurement distance (m) 0.009-0.490 2400/F(kHz) - 300 0.490-1.705 24000/F(kHz) - 30 1.705 - 30.0 30 - 30 30 - 88 100 40 3 88 - 216 150 43.5 3 216 - 960 200 46 3 Above 960 500 54 3 The emission limits shown in the above table are based on measurements employing CISPR quasi-peak detector except for the frequency bands 9-90 kHz, 110-490 kHz and above 1000 MHz. Radiated emission limits in these three bands are based on measurements employing an average detector. For average radiated emission measurements above 1000 MHz, there is also a limit corresponding to 20 dB above the indicated values in the table is specified when measuring with peak detector function. RSS-247: Attenuation below the general field strength limits specified in RSS-Gen is not required. Frequency range tested for Radiated emissions: Start frequency: no radiofrequency signal generated in the device found below 10 th sub-harmonic, no further investigation required. Stop frequency: it has been performed the radiated spurious emissions until 10 th harmonic. DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía, c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España C.I.F. A29507456 Report No: 85236RRF.001A1 Page 156 of 427 2026-05-29 Frequency Range GHz = [0.03, 1] Modulation: The spurious frequencies detected do not depend on either the modulation or the operating channel. Freq Rng (GHz) Equipment Unwanted Freq (MHz) Unwanted Lvl (dBμV/m) Pol Detector Sig Path (dB) Preamp (dB) Trd Corr. (dB/m) Raw Rec (dBμV) [0.03, 1] Frequency Hopping Spread Spectrum systems (DSS) 32.086 14.84 V PK 1.0 0.0 15.0 -1.1 32.086 6.11 V QP 1.0 0.0 15.0 -9.9 424.741 27.33 H PK 3.2 0.0 17.4 6.7 424.741 20.23 H QP 3.2 0.0 17.4 -0.4 542.403 25.00 H PK 3.8 0.0 21.6 -0.5 542.403 17.15 H QP 3.8 0.0 21.6 -8.3 60.215 11.08 V PK 1.2 0.0 6.6 3.2 60.215 5.55 V QP 1.2 0.0 6.6 -2.3 Verdict Pass DEKRA Testing and Certification, …

Text truncated - open the document above for the full version.

Test Report

DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía, c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España C.I.F. A29507456 Report No: 85236RRF.001A1 Page 225 of 427 2026-05-29 DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía, c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España C.I.F. A29507456 Report No: 85236RRF.001A1 Page 226 of 427 2026-05-29 Modulation: BT (8DPSK 3-DH5) Results Equipment Freq Sep (MHz) Frequency Hopping Spread Spectrum systems (DSS) 0.98 Verdict Pass DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía, c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España C.I.F. A29507456 Report No: 85236RRF.001A1 Page 227 of 427 2026-05-29 Attachments Equipment Type = Frequency Hopping Spread Spectrum systems (DSS) Active Port = 1 Modulation = BT (8DPSK 3-DH5) Images: Level in dBm DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía, c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España C.I.F. A29507456 Report No: 85236RRF.001A1 Page 228 of 427 2026-05-29 DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía, c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España C.I.F. A29507456 Report No: 85236RRF.001A1 Page 229 of 427 2026-05-29 RSS-247 6.2.3.1 (b) / FCC 15.247 (a) (1) (iii) Time of Occupancy (Dwell Time) Limits The average time of occupancy on any channel shall not be greater than 0.4 seconds (400 ms) within a period of 0.4 seconds multiplied by the number of hopping channels employed = 0.4 x 79= 31.6 seconds. Modulation: BT (GFSK 1-DH5) Results Equipment Freq (MHz) NHp Avg COT (ms) Frequency Hopping Spread Spectrum systems (DSS) 2402.00000 105 304.900 2441.00000 101 288.880 2480.00000 99 282.920 Verdict Pass DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía, c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España C.I.F. A29507456 Report No: 85236RRF.001A1 Page 230 of 427 2026-05-29 Attachments Equipment Type = Frequency Hopping Spread Spectrum systems (DSS) Active Port = 1 Modulation = BT (GFSK 1-DH5) Frequency = 2402.00000 Images: Level in dBm DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía, c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España C.I.F. A29507456 Report No: 85236RRF.001A1 Page 231 of 427 2026-05-29 Equipment Type = Frequency Hopping Spread Spectrum systems (DSS) Active Port = 1 Modulation = BT (GFSK 1-DH5) Frequency = 2441.00000 Images: Level in dBm DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía, c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España C.I.F. A29507456 Report No: 85236RRF.001A1 Page 232 of 427 2026-05-29 Equipment Type = Frequency Hopping Spread Spectrum systems (DSS) Active Port = 1 Modulation = BT (GFSK 1-DH5) Frequency = 2480.00000 Images: Level in dBm DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía, c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España C.I.F. A29507456 Report No: 85236RRF.001A1 Page 233 of 427 2026-05-29 Modulation: BT (Pi/4 DQPSK 2-DH5) Results Equipment Freq (MHz) NHp Avg COT (ms) Frequency Hopping Spread Spectrum systems (DSS) 2402.00000 102 299.550 2441.00000 111 320.110 2480.00000 102 287.070 Verdict Pass DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía, c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España C.I.F. A29507456 Report No: 85236RRF.001A1 Page 234 of 427 2026-05-29 Attachments Equipment Type = Frequency Hopping Spread Spectrum systems (DSS) Active Port = 1 Modulation = BT (Pi/4 DQPSK 2-DH5) Frequency = 2402.00000 Images: Level in dBm DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía, c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España C.I.F. A29507456 Report No: 85236RRF.001A1 Page 235 of 427 2026-05-29 Equipment Type = Frequency Hopping Spread Spectrum systems (DSS) Active Port = 1 Modulation = BT (Pi/4 DQPSK 2-DH5) Frequency = 2441.00000 Images: Level in dBm DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía, c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España C.I.F. A29507456 Report No: 85236RRF.001A1 Page 236 of 427 2026-05-29 Equipment Type = Frequency Hopping Spread Spectrum systems (DSS) Active Port = 1 Modulation = BT (Pi/4 DQPSK 2-DH5) Frequency = 2480.00000 Images: Level in dBm DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía, c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España C.I.F. A29507456 Report No: 85236RRF.001A1 Page 237 of 427 2026-05-29 Modulation: BT (8DPSK 3-DH5) Results Equipment Freq (MHz) NHp Avg COT (ms) Frequency Hopping Spread Spectrum systems (DSS) 2402.00000 99 284.690 2441.00000 124 369.990 2480.00000 104 301.110 Verdict Pass DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía, c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España C.I.F. A29507456 Report No: 85236RRF.001A1 Page 238 of 427 2026-05-29 Attachments Equipment Type = Frequency Hopping Spread Spectrum systems (DSS) Active Port = 1 Modulation = BT (8DPSK 3-DH5) Frequency = 2402.00000 Images: Level in dBm DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía, c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España C.I.F. A29507456 Report No: 85236RRF.001A1 Page 239 of 427 2026-05-29 Equipment Type = Frequency Hopping Spread Spectrum systems (DSS) Active Port = 1 Modulation = BT (8DPSK 3-DH5) Frequency = 2441.00000 Images: Level in dBm DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía, c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España C.I.F. A29507456 Report No: 85236RRF.001A1 Page 240 of 427 2026-05-29 Equipment Type = Frequency Hopping Spread Spectrum systems (DSS) Active Port = 1 Modulation = BT (8DPSK 3-DH5) Frequency = 2480.00000 Images: Level in dBm DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía, c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España C.I.F. A29507456…

Text truncated - open the document above for the full version.

Test Report

DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía, c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España C.I.F. A29507456 Report No: 85236RRF.001A1 Page 275 of 427 2026-05-29 Operation Band MHz = [2400, 2483.5] Equipment Type = Frequency Hopping Spread Spectrum systems (DSS) Frequency MHz = 2480.00000 Active Port = 1 Modulation = BT (Pi/4 DQPSK 2- DH5) Images: Level in dBm DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía, c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España C.I.F. A29507456 Report No: 85236RRF.001A1 Page 276 of 427 2026-05-29 DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía, c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España C.I.F. A29507456 Report No: 85236RRF.001A1 Page 277 of 427 2026-05-29 Modulation: BT (8DPSK 3-DH5) Results Radiated measurements were used to show compliance with the limits in the restricted bands 2.31-2.39 GHz and 2.4835-2.5 GHz. Verdict Pass DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía, c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España C.I.F. A29507456 Report No: 85236RRF.001A1 Page 278 of 427 2026-05-29 Attachments Operation Band MHz = [2400, 2483.5] Equipment Type = Frequency Hopping Spread Spectrum systems (DSS) Modulation = BT (8DPSK 3-DH5) Active Port = 1 Images: Level in dBm DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía, c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España C.I.F. A29507456 Report No: 85236RRF.001A1 Page 279 of 427 2026-05-29 DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía, c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España C.I.F. A29507456 Report No: 85236RRF.001A1 Page 280 of 427 2026-05-29 Operation Band MHz = [2400, 2483.5] Equipment Type = Frequency Hopping Spread Spect…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Dirk Zamow(Team Leader Approval)
[email protected]Fax: +49711811-5054644

Test Firm

DEKRA Testing and Certification, S.A.U.Rafael Lopez Martin
[email protected]Fax: 34-9562-61 91 13

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz1.48 mW
215C2.40 GHz - 2.48 GHz405.00 µW
Confidentiality
Long Term
Grant Notes
Output power listed is conducted. This device is approved for mobile and fixed use with respect to RF exposure compliance. The antenna of this transmitter must provide a separation distance of at least 20 cm from all persons. Multi-transmitter configurations, supporting simultaneous transmission, have been evaluated as described in this filling. Other multi-transmitter configurations have not been evaluated and shall be evaluated according to KDB Publication 447498 and §2.947(f), §15.31(h) and §15.31(k) composite system and §2.1 terms and concepts.

Other Applications from Robert Bosch GmbH

2AUXS-TFTC7INCH

Instrument cluster with Bluetooth & WiFi for operation in a vehicle

Jul 13, 2026

Equipment Class

DTS - Digital Transmission System
2AUXS-MBCI2LS3PN2

Central In-Vehicle Infotainment Computer

Sep 04, 2025

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
2AUXS-MBCI2LS3PR2

Central In-Vehicle Infotainment Computer

Sep 04, 2025

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
Radio Navigation Systems (NAV), Display Audio systems (DA) - FCC ID 2AUXS-MMCSBXNAR - Robert Bosch GmbH
2AUXS-MMCSBXNAR

Radio Navigation Systems (NAV), Display Audio systems (DA)

Dec 04, 2024

Equipment Class

NII - Unlicensed National Information Infrastructure TX
2AUXS-TCU2NAIP67

Telematics Control Unit Generation 2

Apr 14, 2024

Equipment Class