Wireless cha r Professionalsu pp chargingchip s r ge r Solution pp lierofwireless pp s andsolutions d ucts VersionA 120 * 120 * 12mm VersionB 120 120 12mm 105*105*22mm distance Qi solution ● EKR1030 PCBA ●●Overview Overview WE9012C isalon g PCBA low-frequencymamagneticresona n The maximum chproprietarytechn o adaptivefrequenc PdtPdt Coil Wirelesschargings ●● P ro d uc t spe c P ro d uc t spe c Working frequencyRXoutputTXinputvoltage/c u ChargingareaChargingdistanceProtective function n eticSheet Protective function g -distancewirelesschargingtransmittercompatiblewithQi.It a gneticresonancewirelesschargingtechnologyandconsistsof n cewirelesschargingtransmitteranddesktopmagneticshieldi n arging distance is 30mm. Thisproductutilizesanumberof o logies,includingsplitcoiltechnology,splitshieldingtechno lo g ytrackingtechnology. ifi tiifi ti tandard CompatiblewithQi-BPP/SFC cifi ca ti ons cifi ca ti ons 125 k -135kHz 5W/10WforSamsung u rrent DC24V/1A φ20mm15mm-30mmOver-temperatureprotection,over-voltageprotection,o v currentprotection,foreignbodydetection distance Qi solution ● EKR1030 HUA W ●● Appl i Appl i Hotels,r e h one 8 on 28mm ( 9% ‐ 100% ) rearcan Con v W EI mate 20pro on 28mm ( 1% ‐ 100% ) i cation i cations s e staurants,cafesandotherpublicareas,smarthome(frontan d b i ll db e i nsta ll e d ) KuaiKe v enienceStore HaiDiLaoHotpot NEWCENTURYHOTE L 无线 改 your wire 改 变生活 less life & tĂƌŶŝŶŐ ^ƚĂƚĞŵĞŶƚ ŚĂŶŐĞƐ Žƌ ŵŽĚŝĨŝĐĂƚŝŽŶƐ ŶŽƚ ĞdžƉƌĞƐƐůLJ ĂƉƉƌŽǀĞĚ ďLJ ƚŚĞ ƉĂƌƚLJ ƌĞƐƉŽŶƐŝďůĞ ĨŽƌ ĐŽŵƉůŝĂŶĐĞ ĐŽƵůĚ ǀŽŝĚ ƚŚĞ ƵƐĞƌ͛Ɛ ĂƵƚŚŽƌŝƚLJ ƚŽ ŽƉĞƌĂƚĞ ƚŚĞ ĞƋƵŝƉŵĞŶƚ͘ dŚŝƐ ĞƋƵŝƉŵĞŶƚ ŚĂƐ ďĞĞŶ ƚĞƐƚĞĚ ĂŶĚ ĨŽƵŶĚ ƚŽ ĐŽŵƉůLJ ǁŝƚŚ ƚŚĞ ůŝŵŝƚƐ ĨŽƌ Ă ůĂƐƐ ĚŝŐŝƚĂů ĚĞǀŝĐĞ͕ ƉƵƌƐƵĂŶƚ ƚŽ WĂƌƚ ϭρ ŽĨ ƚŚĞ & ZƵůĞƐ͘ dŚĞƐĞ ůŝŵŝƚƐ Ăƌ Ğ ĚĞƐŝŐŶĞĚ ƚŽ Ɖƌ ŽǀŝĚĞ ƌĞĂƐŽŶĂďůĞ ƉƌŽƚĞĐƚŝŽŶ ĂŐĂŝŶƐƚ ŚĂƌŵĨƵů ŝŶƚĞƌĨĞƌĞŶĐĞ ŝŶ Ă ƌĞƐŝĚĞŶƚŝĂů ŝŶƐƚĂůůĂƚŝŽŶ͘ dŚŝƐ ĞƋƵŝƉŵĞŶƚ ŐĞŶĞƌĂƚĞƐ ƵƐĞƐ ĂŶĚ ĐĂŶ ƌĂĚŝĂƚĞ ƌĂĚŝŽ ĨƌĞƋƵĞŶĐLJ ĞŶĞƌŐLJ ĂŶĚ͕ ŝĨ ŶŽƚ ŝŶƐƚĂůůĞĚ ĂŶĚ ƵƐĞĚ ŝŶ ĂĐĐŽƌĚĂŶĐĞ ǁŝƚŚ ƚŚĞ ŝŶƐƚƌƵĐƚŝŽŶƐ͕ ŵĂLJ ĐĂƵƐĞ ŚĂƌŵĨƵů ŝŶƚĞƌĨĞƌĞŶĐĞ ƚŽ ƌĂĚŝŽ ĐŽŵŵƵŶŝĐĂƚŝŽŶƐ͘ ,ŽǁĞǀĞƌ͕ ƚŚĞƌĞ ŝƐ ŶŽ ŐƵĂƌĂŶƚĞĞ ƚŚĂƚ ŝŶƚĞƌĨĞƌĞŶĐĞ ǁŝůů ŶŽƚ ŽĐĐƵƌ ŝŶ Ă ƉĂ ƌ ƚŝĐƵůĂƌ ŝŶƐƚĂůůĂƚŝŽŶ͘ /Ĩ ƚŚŝƐ ĞƋƵŝƉŵĞŶƚ ĚŽĞƐ ĐĂƵƐĞ ŚĂƌŵĨƵů ŝŶƚĞƌĨĞƌĞŶĐĞ ƚŽ ƌĂĚŝŽ Žƌ ƚĞůĞǀŝƐŝŽŶ ƌĞĐĞƉƚŝŽŶ͕ ǁŚŝĐŚ ĐĂŶ ďĞ ĚĞƚĞƌŵŝŶĞĚ ďLJ ƚƵƌŶŝŶŐ ƚŚĞ ĞƋƵŝƉŵĞŶƚ ŽĨĨ ĂŶĚ ŽŶ͕ ƚŚĞ ƵƐĞƌ ŝƐ ĞŶĐŽƵƌĂŐĞĚ ƚŽ ƚƌLJ ƚŽ ĐŽƌƌĞĐƚ ƚŚĞ ŝŶƚĞƌĨĞƌĞŶĐĞ ďLJ ŽŶĞ Žƌ ŵŽƌĞ ŽĨ ƚŚĞ ĨŽůůŽǁŝŶŐ ŵĞĂƐƵƌĞƐ͗ ‐‐ ZĞŽƌŝĞŶƚ Žƌ ƌĞůŽĐĂƚĞ ƚŚĞ ƌ ĞĐĞŝǀŝŶŐ ĂŶ ƚĞŶŶĂ͘ ‐‐ /ŶĐƌĞĂƐĞ ƚŚĞ ƐĞƉĂƌĂƚŝŽŶ ďĞƚǁĞĞŶ ƚŚĞ ĞƋƵŝƉŵĞŶƚ ĂŶĚ ƌĞĐĞŝǀĞƌ͘ ‐‐ ŽŶŶĞĐƚ ƚŚĞ ĞƋƵŝƉŵĞŶƚ ŝŶƚŽ ĂŶ ŽƵƚůĞƚ ŽŶ Ă ĐŝƌĐƵŝƚ ĚŝĨĨĞƌĞŶƚ ĨƌŽŵ ƚŚĂƚ ƚŽ ǁŚŝĐŚ ƚŚĞ ƌĞĐĞŝǀĞƌ ŝƐ ĐŽŶŶĞĐƚĞĚ͘ ‐‐ ŽŶƐƵůƚ ƚŚĞ ĚĞĂůĞƌ Žƌ ĂŶ ĞdžƉĞƌŝĞŶĐĞĚ ƌĂĚŝŽͬds ƚĞĐŚŶŝĐŝĂŶ ĨŽƌ ŚĞůƉ͘ Z& džƉŽƐƵƌĞ͗ ĚŝƐƚĂŶĐĞ ŽĨ ϭρ Đŵ ƐŚĂůů ďĞ ŵĂŝŶƚĂŝŶĞĚ ďĞƚǁĞĞŶ ƚŚĞ ĂŶƚĞŶŶĂ ĂŶĚ ƵƐĞƌƐ͕ ĂŶĚ ƚŚĞ ƚƌĂŶƐŵŝƚƚĞƌ ŵĂLJ ŶŽƚ ďĞ ĐŽ‐ůŽĐĂƚĞĚ ǁŝƚŚ ĂŶLJ ŽƚŚĞƌ ƚƌĂŶƐŵŝƚƚĞƌ Žƌ ĂŶƚĞŶŶĂ͘ dŚŝƐĚĞǀŝĐĞĐŽŵƉůŝĞƐǁŝƚŚƉĂƌƚϭρŽĨƚŚĞ&ZƵůĞƐ͘KƉĞƌĂƚŝŽŶŝƐƐƵďũĞĐƚƚŽƚŚĞĨŽůůŽǁŝŶŐƚǁŽĐŽŶĚŝƚŝŽŶƐ͗ ;ϭͿdŚ ŝƐĚĞǀŝĐĞŵĂLJŶŽƚĐĂƵƐĞŚĂƌŵĨƵůŝŶƚĞƌĨĞƌĞŶĐĞ͕ĂŶĚ;ϮͿƚŚŝƐĚĞǀŝĐĞŵƵƐƚĂĐĐĞƉƚĂŶLJŝŶƚĞƌĨĞƌĞŶĐĞƌĞĐĞŝ ǀĞĚ͕ŝŶĐůƵĚŝŶŐŝŶƚĞƌĨĞƌĞŶĐĞƚŚĂƚŵĂLJĐĂƵƐĞƵŶĚĞƐŝƌĞĚŽƉĞƌĂƚŝŽŶ͘
Zhejiang Yunkai New Energy Technology Co., Ltd. Agent Authorization Company: Zhejiang Yunkai New Energy Technology Co., Ltd. Address: No.968, XueFengXi Road, YiWu City, Zhejiang Province, China Product Name: Contactless Wireless charger Model Number(s): EKR1030 Product Description: Contactless Wireless charger We authorize MiCOM Labs Inc., 575 Boulder Court, Pleasanton, California 94566, USA, to act on our behalf on all matters concerning the certification of above named equipment. We declare that MiCOM Labs Inc. is allowed to forward all information related to the approval and certification of equipment to the regulatory agencies as required and to discuss any issues concerning the approval application. Any and all acts carried out by MiCOM Labs on our behalf shall have the same effect as acts of our own. Signature: Date: Apr. 07, 2020 Name: Tommy Zhang Title: Manager Company: Zhejiang Yunkai New Energy Technology Co., Ltd.
Zhejiang Yunkai New Energy Technology Co., Ltd. Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 USA Date: Apr. 07, 2020 Subject; Request for Confidentiality FCC ID: 2AV3N-EKR1030 To Whom It May Concern, Pursuant to the provisions of the Commission’s rules Title 47 Sections §0.457 and §0.459, we are requesting the Commission to withhold the following attachment(s) as confidential documents from public disclosure indefinitely. These documents contain detailed system and equipment descriptions and are considered as proprietary information in operation of the equipment. The public disclosure of these documents might be harmful to our company and would give competitors an unfair advantage in the market. Schematic Diagram Block Diagram Parts List Operational Description Tune-up Procedure It is our understanding that all measurement test reports, FCC ID label format and correspondence during the certification review process cannot be granted as confidential documents and this information will be available for public review once the grant of equipment authorization is issued. Sincerely, Signature: Name: Tommy Zhang Title: Manager
Annex A External Photos Report No.:HK2003300521-1E/2E Page 1 of 4 Report No.:HK2003300521-1E/2E Page 2 of 4 Report No.:HK2003300521-1E/2E Page 3 of 4 Report No.:HK2003300521-1E/2E Page 4 of 4
FCC ID LABEL: Ca. 10mm x 15mm Label Location FCC ID: 2AV3N-EKR1030
Annex B Internal Photo Report No.:HK2003300521-1E/2E Page 1 of 3 Antenna Report No.HK2003300521-1E/2E Page 2 of 3 Report No.HK2003300521-1E/2E Page 3 of 3
Page 1 of 8 Report No.: HK2003300521-2E FCC TEST REPORT Test report On Behalf of Zhejiang Yunkai New Energy Technology Co., Ltd. For Contactless Wireless charger Model No.: EKR1030 FCC ID: 2AV3N-EKR1030 Prepared for : Zhejiang Yunkai New Energy Technology Co., Ltd. No.968, XueFengXi Road, YiWu City, Zhejiang Province, China Prepared By : Shenzhen HUAK Testing Technology Co., Ltd. 1F, B2 Building, Junfeng Zhongcheng Zhizao Innovation Park, Fuhai Street, Bao'an District, Shenzhen City, China Date of Test: Mar. 27, 2020 ~ Apr. 03, 2020 Date of Report: Apr. 03, 2020 Report Number: HK2003300521-2E Page 2 of 8 Report No.: HK2003300521-2E Note: 1. For a more detailed features description, please refer to the manufacturer’s specifications or the User's Manual. 2. Channel List Channel Frequency (KHz) Channel Frequency (MHz) Channel Frequency (MHz) Channel Frequency (MHz) 01 125 The EUT antenna is Coil Antenna. No antenna other than that furnished by the responsible party shall be used with the device. 2. SUMMARY OF TEST RESULTS 2.1 Test procedures according to the technical standards: FCC KDB680106 D01 RF Exposure Wireless Charging Apps v03 FCC CFR 47 Standard Section Test Item Judgment Remark FCC CFR 47 part1, 1.1310 KDB680106 D01v03 (3)(3) Electric Field Strength (E) (V/m) PASS Magnetic Field Strength (H) (A/m) PASS 2.2 MEASUREMENT UNCERTAINTY The reported uncertainty of measurement y ±U,where expended uncertainty U is based on a standard uncertainty multiplied by a coverage factor of k=2,providing a level of confidence of approximately 95 %。 No. Item Uncertainty 1 All emissions,radiated(<30M)(9KHz-30MHz) ±2.45dB 2 Temperature ±0.5°C 3 Humidity ±2% Page 3 of 8 Report No.: HK2003300521-2E 2.3 Test Instruments Description Brand Model No. Frequency Range Calibrated Date Calibrated Until Broadband Field Meter NARDA NBM-550 - Dec. 26, 2019 Dec. 25, 2020 Magnetic Field Meter NARDA ELT-400 1 – 400kHz Dec. 26, 2019 Dec. 25, 2020 Magnetic Probe NARDA HF-3061 300kHz – 30MHz Dec. 26, 2019 Dec. 25, 2020 Magnetic Probe NARDA HF-0191 27 – 1000MHz Dec. 26, 2019 Dec. 25, 2020 Broadband Field Meter NARDA NBM-550 - Dec. 26, 2019 Dec. 25, 2020 Electric Field Meter COMBINOVA EFM 2005Hz – 400kHz Dec. 26, 2019 Dec. 25, 2020 E-Field Probe NARDA EF-0391 100kHz – 3GHz Dec. 26, 2019 Dec. 25, 2020 E-Field Probe NARDA EF-6091 100MHz – 60GHz Dec. 26, 2019 Dec. 25, 2020 NOTE: 1. The calibration interval of the above test instruments is 12 months . Page 4 of 8 Report No.: HK2003300521-2E 3. MAXIMUM PERMISSIBLE EXPOSURE 3.1 MAXIMUM PERMISSIBLE EXPOSURE Limit of Maximum Permissible Exposure Limits for Occupational / Controlled Exposure Frequency Range (MHz) Electric Field Strength (E) (V/m) Magnetic Field Strength (H) (A/m) Power Density (S) (mW/ cm²) Averaging Time |E|²,|H|² or S (minutes) 0.3-3.0 614 1.63 (100)* 6 3.0-30 1842 / f 4.89 / f (900 / f)* 6 30-300 61.4 0.163 1.0 6 300-1500 F/300 6 1500-100,000 5 6 Limits for General Population / Uncontrolled Exposure Frequency Range (MHz) Electric Field Strength (E) (V/m) Magnetic Field Strength (H) (A/m) Power Density (S) (mW/ cm²) Averaging Time |E|²,|H|² or S (minutes) 0.3-1.34 614 1.63 (100)* 30 1.34-30 824/f 2.19/f (180 / f)* 30 30-300 27.5 0.073 0.2 30 300-1500 F/1500 30 1500-100,000 1 30 Note 1: f = frequency in MHz ; *Plane-wave equivalent power density Note 2: For the applicable limit, see FCC 1.1310, 680106 D01 RF Exposure Wireless Charging Apps v03 Note 3: Emissions between 100 kHz to 300 kHz should be assessed versus the limits at 300 kHz in Table 1 of Section 1.1310: 614 V/m and 0.815A/m. A KDB inquiry is required to determine the applicable exposure limits below 100 kHz. Page 5 of 8 Report No.: HK2003300521-2E 4. TEST PROCEDURE a. For devices designed for typical desktop applications, such a wireless charging pads, RF exposure evaluation should be conducted assuming a user separation distance of (H-field & E- field strengths for all sides is 15cm, H-field strengths of top side is 20cm). E and H field strength measurements or numerical modeling may be used to demonstrate compliance. Measurements should be made from all sides and the top of the primary/client pair, with the 15 cm measured from the center of the probe(s) to the edge of the device. 4.1 TEST SETUP 4.2 RESULT OF MAXIMUM PERMISSIBLE EXPOSURE Page 6 of 8 Report No.: HK2003300521-2E For Full load mode: E-Field Strength at 15 cm from the edges surrounding the EUT (V/m) Frequency Range (MHz) Test Position A Test Position B Test Position C Test Position D Test Position E Limits Test (V/m) 0.125 1.77 1.52 1.39 1.03 1.13 614 H-Field Strength at 15 cm from the edges surrounding the EUT (A/m) Frequency Range (MHz) Test Position A Test Position B Test Position C Test Position D Test Position E Limits Test (A/m) 0.125 0.74 0.68 0.05 0.17 0.66 0.815 For Half Load mode: E-Field Strength at 15 cm from the edges surrounding the EUT (V/m) Frequency Range (MHz) Test Position A Test Position B Test Position C Test Position D Test Position E Limits Test (V/m) 0.125 1.16 1.52 1.24 1.77 1.36 614 H-Field Strength at 15 cm from the edges surrounding the EUT (A/m) Frequency Range (MHz) Test Position A Test Position B Test Position C Test Position D Test Position E Limits Test (A/m) 0.125 0.27 0.16 0.33 0.19 0.21 0.815 Page 7 of 8 Report No.: HK2003300521-2E For No load mode: E-Field Strength at 15 cm from the edges surrounding the EUT (V/m) Frequency Range (MHz) Test Position A Test Position B Test Position C Test Position D Test Position E Limits Test (V/m) 0.125 1.56 1.16 1.78 1.05 1.34 614 H-Field Strength at 15 cm from the edges surrounding the EUT (A/m) Frequency Range (MHz) Test Position A Test Position B Test Position C Test Position D Test Position E Limits Test (A/m) 0.125 0.52 0.24 0.63 0.49 0.56 0.815 Remark: According KDB 680106 D01 RF Exposure Wireless Charging App v03, section 5, b). The aggregate H-field strengths at 15 cm surrounding the device and 20 cm above the top surface from all simultaneous transmitting coil…
Text truncated - open the document above for the full version.
Page 1 of 20 Report No.: HK2003300521-1E FCC TEST REPORT Test report On Behalf of Zhejiang Yunkai New Energy Technology Co., Ltd. For Contactless Wireless charger Model No.: EKR1030 FCC ID: 2AV3N-EKR1030 Prepared for : Zhejiang Yunkai New Energy Technology Co., Ltd. No.968, XueFengXi Road, YiWu City, Zhejiang Province, China Prepared By : Shenzhen HUAK Testing Technology Co., Ltd. 1F, B2 Building, Junfeng Zhongcheng Zhizao Innovation Park, Fuhai Street, Bao'an District, Shenzhen City, China Date of Test: Mar. 27, 2020 ~ Apr. 03, 2020 Date of Report: Apr. 03, 2020 Report Number: HK2003300521-1E Page 2 of 20 Report No.: HK2003300521-1E TEST RESULT CERTIFICATION Applicant’s name ................. : Zhejiang Yunkai New Energy Technology Co., Ltd. Address ................................. : No.968, XueFengXi Road, YiWu City, Zhejiang Province, China Manufacture's Name ............ : Zhejiang Yunkai New Energy Technology Co., Ltd. Address ................................. : No.968, XueFengXi Road, YiWu City, Zhejiang Province, China Product description Trade Mark: EKR Product name ........................... : Contactless Wireless charger Model and/or type reference : EKR1030 Standards ............................. : FCC Rules and Regulations Part 15 Subpart C (Section 15.209), ANSI C63.10: 2013 This publication may be reproduced in whole or in part for non-commercial purposes as long as the Shenzhen HUAK Testing Technology Co., Ltd. is acknowledged as copyright owner and source of the material. Shenzhen HUAK Testing Technology Co., Ltd. takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. Date of Test ............................................ : Date (s) of performance of tests ............. : Mar. 27, 2020 ~ Apr. 03, 2020 Date of Issue ........................................... : Apr. 03, 2020 Test Result ............................................... : Pass Testing Engineer : (Gary Qian) Technical Manager : (Eden Hu) Authorized Signatory : (Jason Zhou) Page 3 of 20 Report No.: HK2003300521-1E Table of Contents Page 1 . TEST SUMMARY 4 1.1 TEST PROCEDURES AND RESULTS 错误!未定义书签。 1.2 TEST FACILITY 错误!未定义书签。 1.3 MEASUREMENT UNCERTAINTY 错误!未定义书签。 2. GENERAL INFORMATION 5 2.1 General Description of EUT 5 2.2. Carrier Frequency of Channels 6 2.3 Operation of EUT during testing 6 2.4 Description of Test Setup 6 2.5 Measurement Instruments List 7 3. CONDUCTED EMISSION TEST 8 3.1 Block Diagram of Test Setup 8 3.2 Conducted Power Line Emission Limit 8 3.3 Test Procedure 8 3.4 Test Result 8 4. Occupied Bandwidth 11 4.1 Block Diagram of Test Setup 11 4.2 Rules and specifications 11 4.3 Test Procedure 11 4.4 Test Result 11 5. RADIA TED EMISSIONS 13 5.1 Block Diagram of Test Setup 13 5.2 Rules and specifications 14 5.3 Test Procedure 15 5.4 Test Result 15 6 ANTENNA REQUIREMENT 18 7. PHOTOGRAPH OF TEST 19 7.1 Radiated Emission 19 7.2 Conducted Emission 20 8. PHOTOGRAPH OF TEST 20 Page 4 of 20 Report No.: HK2003300521-1E 1. TEST SUMMARY 1.1 TEST PROCEDURES AND RESULTS DESCRIPTION OF TEST section number CONDUCTED EMISSIONS TEST 15.207 RADIATED EMISSION TEST 15.209 OCCUPIED BANDWIDTH MEASUREMENT 15.215 RESULT COMPLIANT COMPLIANT COMPLIANT ANTENNA REQUIREMENT 15.203 COMPLIANT Note: 1. PASS: Test item meets the requirement. 2. Fail: Test item does not meet the requirement. 3. N/A: Test case does not apply to the test object. 4. The test result judgment is decided by the limit of test standard. 1.2 TEST FACILITY Test Firm : Shenzhen HUAK Testing Technology Co., Ltd. Address 1F, B2 Building, Junfeng Zhongcheng Zhizao Innovation Park, Fuhai Street, Bao'an District, Shenzhen City, China 1.3 MEASUREMENT UNCERTAINTY Measurement Uncertainty Conducted Emission Expanded Uncertainty =2.23dB, k=2 Radiated emission expanded uncertainty(9kHz-30MHz) = 3.08dB, k=2 Radiated emission expanded uncertainty(30MHz-1000MHz)= 4.42dB, k=2 Radiated emission expanded uncertainty(Above 1GHz) = 4.06dB, k=2 Page 5 of 20 Report No.: HK2003300521-1E 2. GENERAL INFORMATION 2.1 General Description of EUT Equipment Contactless Wireless charger Model Name EKR1030 Serial No. N/A Model Difference N/A Trade Mark EKR FCC ID 2AV3N-EKR1030 Antenna Type Coil Antenna Antenna Gain 1dBi BT Operation frequency 125KHz Number of Channels 1 Modulation Type ASK Power Source Input: DC24V, 1A from Adapter With AC100-240V, 50/60Hz,1.0A DC5V, 1A(wireless Output) Power Rating Input: DC24V, 1A from Adapter With AC100-240V, 50/60Hz,1.0A DC5V, 1A(wireless Output) Page 6 of 20 Report No.: HK2003300521-1E 2.2. Carrier Frequency of Channels Operation Frequency each of channel Channel Frequency 1 125KHz 2.3 Operation of EUT during testing Operating Mode The mode is used: Transmitting mode 2.4 Description of Test Setup Operation of EUT during testing AC Plug Setup: Transmission mode ● Adapter information Model: GFD-2401000JH Input: 100-240V~, 50/60Hz, 1A Output: 24VDC, 1A ● Mobile phones information Model: S6 Input: 5VDC Adapter EUT Mobile phones Page 7 of 20 Report No.: HK2003300521-1E 2.5 Measurement Instruments List Item Equipment Manufacturer Model No.Serial No. Last Cal. Cal. Interval 1. L.I.S.N. Artificial Mains Network R&S ENV216 HKE-002 Dec. 26, 20191 Year 2. Receiver R&S ESCI 7 HKE-010 Dec. 26, 20191 Year 3. RF automatic control unit Tonscend JS0806-2 HKE-060 Dec. 26, 20191 Year 4. Spectrum analyzer R&S FSP40 HKE-025 Dec. 26, 20191 Year 5. Spectrum analyzer Agilent N9020A HKE-048 Dec. 26, 20191 Year 6. Preamplifier Schwarzbeck BBV 9743HKE-006 Dec. 26, 20191 Year 7. EMI Test Receiver Rohde & SchwarzESCI 7 HKE-010 Dec. 26, 20191 Year 8. Bilog Broadband Antenna Schwarzbeck VULB9163HKE-012 Dec. 26, 20191 Year 9. Loop Antenna Schwarzbeck FMZB 1519 B HKE-014 Dec. 26, 20191 Year 10. Horn Antenna Schewarzbeck 9120D HKE-013 Dec. 26, 20191 Year 11. Pre-amplifier EMCI EMC051845 SE HKE-015 Dec. 26, 20191 Year 12. Pre-amplifier Agilent 83051A HKE-016 Dec. …
Text truncated - open the document above for the full version.
Test Model:EKR1030 Radiated Emission Conducted Emission
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 0.125 MHz - 0.125 MHz | - |

Contactless Wireless Charger
Equipment Class
8CC - Part 18 Consumer Device