Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
This equipment should be installed and operated with minimum distance 20cm between the radiator&your body.
Model difference declaration letter Differences Description We TIGER&ROSE TECHNOLOGY L.L.C. state: Product: WiFi Smart Plug Model Name: LSPA6, LSPA5, LSPA7, LSPA8, LSPA9, LSPA10 The above product with same circuit, PCB layout, electrical parts, materials and wiring structures, Appearance shape, the materials of decorative accessories is same, only different color, Signatory Date: 2020-05-15 Signature Name: Zhou Zhou Title: Manager Company: SHENZHEN LONG SI PU TECHNOLOGY LIMITED Address: Rm106, Xingqiang Bldg B, No.4, Shilong Str, Baoan Dist. Shenzhen.
SHENZHEN LONG SI PU TECHNOLOGY LIMITED (May 06. 2020) MET Laboratories, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: CONFIDENTIALITY REQUEST FOR EUT: WiFi Smart Plug Model: LSPA6, LSPA5, LSPA7, LSPA8, LSPA9, LSPA10 FCC ID: 2AV9Z-LSPA6 To Whom It May Concern: This letter serves as an official request for confidentiality under sections 0.457 and 0.459 of CFR 47. We have requested that the -Schematic -Block diagram -Operation description required to be submitted with this application be permanently withheld from public review. the above documents are company proprietary information that could never get into the possession of your competition). Please contact me if there is any information you may need. Sincerely, Signature Name: Zhou Zhou Title: Manager Company: SHENZHEN LONG SI PU TECHNOLOGY LIMITED Address: Rm106, Xingqiang Bldg B, No.4, Shilong Str, Baoan Dist. Shenzhen.
SHENZHEN LONG SI PU TECHNOLOGY LIMITED (May 06. 2020) Eurofins MET Labs 914 West Patapsco Avenue Baltimore, MD 21230 RE: LETTER OF AGENT AUTHORIZATION To Whom It May Concern: We, the undersigned, hereby authorize Flux Compliance Service Laboratory to act on our behalf in all matters relating to application for equipment authorization, including the signing of all documents relating to these matters. We also hereby certify that no party to the application authorized hereunder is subject to the denial of benefits, including FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C.853(a). This agreement expires one year from the current date. Sincerely, Signature Name: Zhou Zhou Title: Manager Company: SHENZHEN LONG SI PU TECHNOLOGY LIMITED Address: Rm106, Xingqiang Bldg B, No.4, Shilong Str, Baoan Dist. Shenzhen.
External photos Photo 1 Photo 2 Photo 3 Photo 4 Photo 5
Label and Label Location FCC ID: 2AV9Z-LSPA6 L*W: 10mm*7mm white font on a Black label
Page 1 of 2 Report No.: FCS202004012W01 Flux Compliance Service Laboratory Room 105 Floor Bao hao Technology Building 1 NO.15 Gong ye West Road Hi-Tech Industrial, Song shan lake Dongguan Tel: 769-27280901 Fax:769-27280901 http://www.FCS-lab.com FCC RF Exposure EUT Description: WiFi Smart Plug Model No.: LSPA6 FCC ID: 2AV9Z-LSPA6 1. Limits The criteria listed in the following table shall be used to evaluate the environment impact of human exposure to radio frequency (RF) radiation as specified in 1.1307(b) Limits for Maximum Permissible Exposure (MPE) F = frequency in MHz Formula: Pd = (Pout*G)/(4*π*r 2 ) Where : Pd = power density in mW/cm 2 , Pout = output power to antenna in mW; G = gain of antenna in linear scale, π= 3.14; R = distance between observation point and center of the radiator in cm Pd id the limit of MPE, 1 mW/cm2. If we know the maximum gain of the antenna and the total power input to the antenna, through the calculation, we will know the distance r where the MPE limit is reached. Page 2 of 2 Report No.: FCS202004012W01 Flux Compliance Service Laboratory Room 105 Floor Bao hao Technology Building 1 NO.15 Gong ye West Road Hi-Tech Industrial, Song shan lake Dongguan Tel: 769-27280901 Fax:769-27280901 http://www.FCS-lab.com 2. Test Procedure Software provided by client enabled the EUT to transmit and receive data at lowest, middle and highest channel individually. 3. Test Result of RF Exposure Evaluation Output power (dBm/ mW) Antenna Gain(dBi) Power Density at R=20cm (mW/cm 2 ) Limit (mW/cm 2 ) Result 802.11b 16.89/48.87 2.0 0.019 1.0 Pass 802.11g 18.41/69.34 2.0 0.028 1.0 Pass 802.11n(20MHz) 20.59/114.55 2.0 0.046 1.0 Pass 802.11n(40MHz) 17.54/56.75 2.0 0.023 1.0 Pass Turn-up power Mode Peak power range(dBm) WIFI 15.00-21.00 WIFI Output power (dBm/ mW) Antenna Gain(dBi) Power Density at R=20cm (mW/cm 2 ) Limit (mW/cm 2 ) Result 21.00/125.89 2.0 0.050 1.0 Pass Conclusion: No SAR is required
FCC Test Report Report No: FCS202004012W01 Issued for SHENZHEN LONG SI PU TECHNOLOGY LIMITED Rm106, Xingqiang Bldg B, No.4, Shilong Str, Baoan Dist. Shenzhen. Product Name: WiFi Smart Plug Brand Name: N/A Model Name: LSPA6 Series Model: LSPA5, LSPA7, LSPA8, LSPA9, LSPA10 FCC ID: 2AV9Z-LSPA6 Test Standard: FCC Part 15.247 Issued By: Flux Compliance Service Laboratory Add: Room 105 Floor Bao hao Technology Building 1 NO.15 Gong ye West Road Hi-Tech Industrial, Song shan lake Dongguan Tel: 769-27280901 Fax:769-27280901 http://www.FCS-lab.com Page 2 of 80 Report No.: FCS202004012W01 Flux Compliance Service Laboratory Room 105 Floor Bao hao Technology Building 1 NO.15 Gong ye West Road Hi-Tech Industrial, Song shan lake Dongguan Tel: 769-27280901 Fax:769-27280901 http://www.FCS-lab.com TEST RESULT CERTIFICATION Applicant’s Name ................... : SHENZHEN LONG SI PU TECHNOLOGY LIMITED Address .................................. : Rm106, Xingqiang Bldg B, No.4, Shilong Str, Baoan Dist. Shenzhen. Manufacture's Name .............. : SHENZHEN LONG SI PU TECHNOLOGY LIMITED Address .................................. : Rm106, Xingqiang Bldg B, No.4, Shilong Str, Baoan Dist. Shenzhen. Product Description Product Name ........................ : WiFi Smart Plug Brand Name ......................... : N/A Model Name ........................... : LSPA6 Series Model .......................... : LSPA5, LSPA7, LSPA8, LSPA9, LSPA10 Test Standards ....................... : FCC Part15.247 Test Procedure ....................... : ANSI C63.10-2013 This device described above has been tested by Flux Compliance Service Laboratory, the test results show that the equipment under test (EUT) is in compliance with the FCC requirements. And it is applicable only to the tested sample identified in the report. This report shall not be reproduced except in full, without the written approval of Flux Compliance Service Laboratory, this document may be altered or revised by Flux Compliance Service Laboratory, personal only, and shall be noted in the revision of the document.. Date of Test .............................. : Date (s) of performance of tests : 27 April 2020 to 08 May 2020 Date of Issue ............................. : 08 May 2020 Test Result ................................. : Pass Tested by : (Chris Chen) Reviewed by : (Jack Chen) Approved by : ( Andy yue) Page 3 of 80 Report No.: FCS202004012W01 Flux Compliance Service Laboratory Room 105 Floor Bao hao Technology Building 1 NO.15 Gong ye West Road Hi-Tech Industrial, Song shan lake Dongguan Tel: 769-27280901 Fax:769-27280901 http://www.FCS-lab.com Table of Contents Page 1. SUMMARY OF TEST RESULTS 6 1.1 TEST FACTORY 7 1.2 MEASUREMENT UNCERTAINTY 7 2. GENERAL INFORMATION 8 2.1 GENERAL DESCRIPTION OF THE EUT 8 2.2 BLOCK DIGRAM SHOWING THE CONFIGURATION OF SYSTEM TESTED 10 2.3 DESCRIPTION OF NECESSARY ACCESSORIES AND SUPPORT UNITS 11 2.4 EQUIPMENTS LIST 12 3. 6DB BANDWIDTH 13 3.1 LIMIT 13 3.2 TEST PROCEDURE 13 3.3 TEST SETUP 13 3.4 TEST RESULTS 14 4 CONDUCTED OUTPUT POWER 21 4.1 LIMIT 21 4.2 TEST PROCEDURE 21 4.3 TEST SETUP 21 4.5 TEST RESULTS 21 5. POWER SPECTRAL DENSITY 28 5.1 LIMIT 28 5.2 TEST PROCEDURE 28 5.3 TEST SETUP 28 5.5 TEST RESULTS 29 5.6 ORIGINAL TEST DATA 30 6. BAND EDGE AND SPURIOUS(CONDUCTED) 36 6.1 LIMIT 36 6.2 TEST PROCEDURE 36 6.3 TEST SETUP 36 6.5 TEST RESULTS 37 6.5 ORIGINAL TEST DATA 37 7 RADIATED EMISSION MEASUREMENT 60 8 CONDUCTED EMISSION TEST 76 Page 4 of 80 Report No.: FCS202004012W01 Flux Compliance Service Laboratory Room 105 Floor Bao hao Technology Building 1 NO.15 Gong ye West Road Hi-Tech Industrial, Song shan lake Dongguan Tel: 769-27280901 Fax:769-27280901 http://www.FCS-lab.com Table of Contents Page 9. ANTENNA REQUIREMENT 80 9.1 STANDARD REQUIREMENT 80 9.2 RESULT 80 Page 5 of 80 Report No.: FCS202004012W01 Flux Compliance Service Laboratory Room 105 Floor Bao hao Technology Building 1 NO.15 Gong ye West Road Hi-Tech Industrial, Song shan lake Dongguan Tel: 769-27280901 Fax:769-27280901 http://www.FCS-lab.com Revision History Rev. Issue Date Report NO. Effect Page Contents 00 08 May 2020 FCS202004012W01 ALL Initial Issue Page 6 of 80 Report No.: FCS202004012W01 Flux Compliance Service Laboratory Room 105 Floor Bao hao Technology Building 1 NO.15 Gong ye West Road Hi-Tech Industrial, Song shan lake Dongguan Tel: 769-27280901 Fax:769-27280901 http://www.FCS-lab.com 1. SUMMARY OF TEST RESULTS Test procedures according to the technical standards: KDB 558074 D01 15.247 Meas Guidance v05r02 FCC Part 15.247,Subpart C Standard Section Test Item Judgment Remark FCC 15.247 (a) (2) 6dB Bandwidth PASS -- FCC 15.247 (b) (3) Conducted Output Power PASS -- FCC 15.247 (e) Power Spectral Density PASS -- FCC 15.247 (d) Band-edge and Spurious Emissions (Conducted) PASS -- FCC 15.247 (d) FCC 15.209 FCC 15.205 Radiated Spurious Emissions PASS -- FCC 15.247 (d) FCC 15.209 FCC 15.205 Radiated Band Edge Compliance PASS -- FCC 15.207 Power Line Conducted Emission PASS -- FCC 15.203 Antenna requirement PASS -- 15.205 Restricted Band Edge Emission PASS -- NOTE: (1)” N/A” denotes test is not applicable in this Test Report (2) All tests are according to ANSI C63.10-2013 Page 7 of 80 Report No.: FCS202004012W01 Flux Compliance Service Laboratory Room 105 Floor Bao hao Technology Building 1 NO.15 Gong ye West Road Hi-Tech Industrial, Song shan lake Dongguan Tel: 769-27280901 Fax:769-27280901 http://www.FCS-lab.com 1.1 TEST FACTORY Company Name: Flux Compliance Service Laboratory Address: Room 105 Floor Bao hao Technology Building 1 NO.15 Gong ye West Road Hi-Tech Industrial, Song shan lake Dongguan Telephone: +86-769-27280901 Fax: +86-769-27280901 FCC Test Firm Registration Number: 514908 Designation number: CN0127 A2LA accreditation number:5545.01 1.2 MEASUREMENT UNCERTAINTY The reported uncertainty of measurement y ±U, where expended uncertainty U is based on a standard uncertainty multiplied by a coverage factor of k=2, providing a level of confidence of app…
Text truncated - open the document above for the full version.
Blow 1GHz for radiated emission test setup Above 1GHz for radiated emission test setup Conducted Emission test setup
Room 105 Floor Bao hao Technology Building 1 NO.15 · Dongguan, Guangdong · China
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.41 GHz - 2.46 GHz | 114.55 mW |

Wi-Fi Switch
Equipment Class
DTS - Digital Transmission System