FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. SHENZHEN LONG SI PU TECHNOLOGY LIMITED/
  3. 2AV9Z-LSPS9

2AV9Z-LSPS9Wi-Fi Switch

SHENZHEN LONG SI PU TECHNOLOGY LIMITED
Wi-Fi Switch - FCC ID 2AV9Z-LSPS9 - SHENZHEN LONG SI PU TECHNOLOGY LIMITED
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Sep 27, 2022
Application Purpose
Original Equipment
Date of Application
Sep 27, 2022
Equipment Note
Wi-Fi Switch
Frequency Range
2412.00000000 - 2462.00000000
Company
SHENZHEN LONG SI PU TECHNOLOGY LIMITED
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Attestation Statements

Modeldifferencedeclarationletter DifferencesDescription WeSHENZHENLONGSIPUTECHNOLOGYLIMITEDstate: Product:Wi-FiSwitch ModelName: LSPS1,LSPS2,LSPS3,LSPS5,LSPS6,LSPS7,LSPS8, LSPS9,LSPS10 Theaboveproductwithsamecircuit,PCBlayout,electricalparts,materialsand wiringstructures,Appearanceshape,thematerialsofdecorativeaccessoriesis same,onlydifferentcolor. Signatory Date:09-15-2022 <Signature> Name:ZhouZhou Title:Manager Company:SHENZHENLONGSIPUTECHNOLOGYLIMITED Address:Rm106,XingqiangBldgB,No.4,ShilongStr,BaoanDist,Shenzhenchina

Cover Letter(s)

C5266091_X8_Ed.1 1/1 LetterofAuthorization SHENZHENLONGSIPUTECHNOLOGYLIMITED Company:SHENZHENLONGSIPUTECHNOLOGYLIMITED Address:Rm106,XingqiangBldgB,No.4,ShilongStr,BaoanDist,Shenzhen china ProductName:Wi-FiSwitch ModelNumber:LSPS1,LSPS2,LSPS3,LSPS5,LSPS6,LSPS7,LSPS8,LSPS9, LSPS10 FCCIdentifier:2AV9Z-LSPS9 WeauthorizeLGAITechnologicalCenterS.A.,RondadelaFontdelCarme,s/n, 08193Bellaterra,Spain,toactonourbehalfonallmattersconcerningthe abovenamedequipment. AnyindividualwithinLGAITechnologicalCenterS.A.isauthorizedtoactonour behalfandtakeactionontheapplication. WedeclarethatauthorizeLGAITechnologicalCenterS.A.,RondadelaFontdel Carme,s/n,08193Bellaterra,Spain,isallowedtoforwardallinformation relatedtotheapprovalprojecttotheFederalCommunicationCommissionand todiscussanyissuesconcerningtheapprovalapplication.Anyandallacts carriedoutbyLGAITechnologicalCenterS.A.onourbehalfshallhavethe sameeffectasactsofourown. Name:ZhouZhouDate:Sep15,2022 Title:Manager Signatureofapplicant:

Cover Letter(s)

C5266091_X10_Ed.2 1/1 SHENZHENLONGSIPUTECHNOLOGYLIMITED OfficeofEngineeringTechnology FederalCommunicationsCommission 7435OaklandMillsRoad Columbia,MD21046 Date:Sep15,2021 Subject:RequestforConfidentiality FCCID: 2AV9Z-LSPS9 ToWhomItMayConcern, PursuanttotheprovisionsofSections0.457and0.459ofCommission'srules (47CFR0.457,0.459),wearerequestingtheCommissiontowithholdthefollowing attachment(s)asconfidentialdocumentfrompublicdisclosure. ExhibitsLong-Term Confidentiality Short-Term Confidentiality NOTE2 IDLabel/LocationNoNo AttestationStatementNoNo ExternalPhotosNo ☐ BlockDiagram ☒☐ Schematics ☒☐ TestReportNoNo TestSetupPhotosNo ☐ User’sManual ☐ NOTE 1 ☐ InternalPhotos ☐ NOTE 1 ☐ PartsList/TuneUp ☒☐ RFExposureInfoNo OperationalDescription No ☒☐ CoverLetter(s)NoNo SDRSoftware/SecurityInfo ☐ No NOTE1:Long-TermConfidentialitymaybepermittedunderspecialconditions(SeeII.LONG-TERMCONFIDENTIALITY,Section3of KDB726920,uselastinforce) NOTE2:Short-TermConfidentialitycanberequestedforamaximumof180daysfromthedateofthegrant. Abovementioneddocumentcontainsdetailedsystemandequipmentdescriptionare consideredasproprietaryinformationinoperationoftheequipment.Thepublic disclosureofabovedocumentsmightbeharmfultoourcompanyandwouldgive competitoranunfairadvantageinthemarket. Incaseofshort-termConfidentiality,theapplicantrequeststheexhibitsselected abovearewithheldfrompublicviewforaperiodof______daysfromthedateofthe GrantofEquipmentAuthorizationandpriortomarketing. Itisourunderstandingthatallmeasurementtestreports,FCCIDlabelformatand correspondentduringcertificationreviewprocesscannotbegrantedasconfidential documentsandthoseinformationwillbeavailableforpublicreviewoncethegrantof equipmentauthorizationisissued. C5266091_X10_Ed.2 1/1 Sincerely, Signature: Name:ZhouZhou Title: Manager

External Photos

Page1of3ReportNo.:FCS202208153 Externalphotos Photo1 Photo2 Page2of3ReportNo.:FCS202208153 Photo3 Photo4 Page3of3ReportNo.:FCS202208153 Photo5 Photo6

ID Label/Location Info

LabelandLabelLocation FCCID:2AV9Z-LSPS9

Internal Photos

Page1of2ReportNo.:FCS202208153 Internalphotos Photo1 Photo2 Page2of2ReportNo.:FCS202208153 Photo3 Photo4 Page3of2ReportNo.:FCS202208153 Photo5 Photo6 ANT

RF Exposure Info

Page1of2ReportNo.:FCS202208153W02 FluxComplianceServiceLaboratory Room105FloorBaohaoTechnologyBuilding1NO.15GongyeWestRoadHi-TechIndustrial,SongshanlakeDongguan Tel:769-27280901Fax:769-27280901http://www.FCS-lab.com FCCRFExposure 1.Limits Thecriterialistedinthefollowingtableshallbeusedtoevaluatetheenvironmentimpactofhuman exposuretoradiofrequency(RF)radiationasspecifiedin1.1307(b EUT Description:Wi-Fi Switch ModelNo.:LSPS1,LSPS2,LSPS3,LSPS5,LSPS6,LSPS7,LSPS8,LSPS9,LSPS10 FCC ID:2AV9Z-LSPS9 Equipment type:Mobile equipment ) LimitsforMaximumPermissibleExposure(MPE) F=frequencyinMHz Formula:Pd=(Pout*G)/(4*π*r 2 ) Where: Pd=powerdensityinmW/cm 2 , Pout=outputpowertoantennainmW; G=gainofantennainlinearscale, π=3.14; R=distancebetweenobservationpointandcenteroftheradiatorincm PdidthelimitofMPE,1mW/cm2.Ifweknowthemaximumgainoftheantennaandthetotalpower inputtotheantenna,throughthecalculation,wewillknowthedistancerwheretheMPElimitis reached. 2.TestProcedure SoftwareprovidedbyclientenabledtheEUTtotransmitandreceivedataatlowest,middleandhighest channelindividually. Page2of2ReportNo.:FCS202208153W02 FluxComplianceServiceLaboratory Room105FloorBaohaoTechnologyBuilding1NO.15GongyeWestRoadHi-TechIndustrial,SongshanlakeDongguan Tel:769-27280901Fax:769-27280901http://www.FCS-lab.com 3.TestResultofRFExposureEvaluation Outputpower (dBm/mW) Antenna Gain(dBi) PowerDensity atR=20cm (mW/cm 2 ) Limit (mW/cm 2 ) Result 802.11b8.26/6.69881.370.001831.0Pass 802.11g7.48/5.59761.370.001531.0Pass 802.11n(20MHz)6.92/4.92041.370.001341.0Pass 802.11n(40MHz)6.59/4.56041.370.001241.0Pass Turn-uppower ModePeakpowerrange(dBm) WIFI6.00-9.00 WIFI Outputpower (dBm/mW) Antenna Gain(dBi) PowerDensity atR=20cm (mW/cm 2 ) Limit (mW/cm 2 ) Result 9.0/7.94331.370.002171.0Pass

Test Report

FCCTestReport ReportNo:FCS202208153W01 Issuedfor Applicant: SHENZHENLONGSIPUTECHNOLOGYLIMITED Address: Rm106,XingqiangBldgB,No.4,ShilongStr,BaoanDist, Shenzhenchina ProductName: Wi-FiSwitch BrandName: N/A ModelName: LSPS9 SeriesModel: LSPS1,LSPS2,LSPS3,LSPS5,LSPS6,LSPS7,LSPS8, LSPS9,LSPS10 FCCID: 2AV9Z-LSPS9 IssuedBy:FluxComplianceServiceLaboratory Add:Room105FloorBaohaoTechnologyBuilding1NO.15GongyeWestRoadHi-Tech Industrial,SongshanlakeDongguan Tel:769-27280901Fax:769-27280901http://www.FCS-lab.com Page 2 of61ReportNo.:FCS202208153W01 FluxComplianceServiceLaboratory Room105FloorBaohaoTechnologyBuilding1NO.15GongyeWestRoadHi-TechIndustrial,SongshanlakeDongguan Tel:769-27280901Fax:769-27280901http://www.FCS-lab.com TESTRESULTCERTIFICATION Applicant’sName......................:SHENZHENLONGSIPUTECHNOLOGYLIMITED Address......................................: Rm106,XingqiangBldgB,No.4,ShilongStr,BaoanDist, Shenzhenchina Manufacture'sName ................ :SHENZHENLONGSIPUTECHNOLOGYLIMITED Address ...................................... : Rm106,XingqiangBldgB,No.4,ShilongStr,BaoanDist, Shenzhenchina ProductDescription ProductName...........................:Wi-FiSwitch BrandName.............................: N/A ModelName .............................. :LSPS9 SeriesModel..............................: LSPS1,LSPS2,LSPS3,LSPS5,LSPS6,LSPS7,LSPS8,LSPS9, LSPS10 TestStandards..........................:FCCRulesandRegulationsPart15SubpartC,Section247 TestProcedure..........................:ANSIC63.10-2013 ThisdevicedescribedabovehasbeentestedbyFluxComplianceServiceLaboratory,thetest resultsshowthattheequipmentundertest(EUT)isincompliancewiththeFCCrequirements.Andit isapplicableonlytothetestedsampleidentifiedinthereport. Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofFluxCompliance ServiceLaboratory,thisdocumentmaybealteredorrevisedbyFluxComplianceService Laboratory,personalonly,andshallbenotedintherevisionofthedocument.. DateofTest .................................. : Date(s)ofperformanceoftests . :Aug,222022~Aug,312022 DateofIssue ................................. :Aug,312022 TestResult.....................................:Pass Testedby: (ScottShen) Reviewedby : (DukeQian) Approvedby: ( JackWang ) Page 3 of61ReportNo.:FCS202208153W01 FluxComplianceServiceLaboratory Room105FloorBaohaoTechnologyBuilding1NO.15GongyeWestRoadHi-TechIndustrial,SongshanlakeDongguan Tel:769-27280901Fax:769-27280901http://www.FCS-lab.com TableofContentsPage 1.SUMMARYOFTESTRESULTS..............................................................................................6 1.1TESTFACTORY................................................................................................................7 1.2MEASUREMENTUNCERTAINTY.....................................................................................7 2.GENERALINFORMATION.......................................................................................................8 2.1GENERALDESCRIPTIONOFTHEEUT..........................................................................8 2.2BLOCKDIGRAMSHOWINGTHECONFIGURATIONOFSYSTEMTESTED.............10 2.3DESCRIPTIONOFNECESSARYACCESSORIESANDSUPPORTUNITS.................11 2.4EQUIPMENTSLIST.........................................................................................................12 3.6DBBANDWIDTH..................................................................................................................13 3.1Limit..................................................................................................................................13 3.2TestProcedure.................................................................................................................13 3.3Testsetup.........................................................................................................................13 3.4Testresults.......................................................................................................................14 4CONDUCTEDOUTPUTPOWER............................................................................................21 4.1limit...................................................................................................................................21 4.2testprocedure..................................................................................................................21 4.3TESTSETUP...................................................................................................................21 4.4testresults........................................................................................................................21 5.POWERSPECTRALDENSITY..............................................................................................22 5.1LIMIT................................................................................................................................22 5.2TESTPROCEDURE........................................................................................................22 5.3TESTSETUP...................................................................................................................22 5.4TESTRESULTS...............................................................................................................23 5.5originaltestdata...............................................................................................................24 6.Bandedgeandspurious(conducted).................................................................................30 6.1LIMIT................................................................................................................................30 6.2TESTPROCEDURE........................................................................................................30 6.3TESTSETUP...................................................................................................................30 6.5TESTRESULTS....................................…

Text truncated - open the document above for the full version.

Test Report

Unit: MHz XY Unit:dBi XZ YZ Unit:dBi Unit:dBi Unit: MHz Unit: MHz

Test Setup Photos

Page1of2ReportNo.:FCS202208153 Page2of2ReportNo.:FCS202208153

Contact Information

Applicant

Zhou zhou
[email protected]0755-27280901Fax: 0755-27280901

Technical Contact

Flux Compliance Service LaboratoryAndy yue
[email protected]86-769-27280901

Dongguan · China

Non-Technical Contact

Flux Compliance Service LaboratoryAndy yue
[email protected]86-769-27280901

Test Firm

Flux Compliance Service LaboratoryAndy Yue
[email protected]13510297284

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.41 GHz - 2.46 GHz6.70 mW
Confidentiality
Long Term
Grant Notes
Output power listed is conducted. This device has 40 MHz bandwidth mode. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and not be co-located with any other transmitters except in accordance with FCC multi-transmitter product procedures. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.

Other Applications from SHENZHEN LONG SI PU TECHNOLOGY LIMITED

WiFi Smart Plug - FCC ID 2AV9Z-LSPA6 - SHENZHEN LONG SI PU TECHNOLOGY LIMITED
2AV9Z-LSPA6

WiFi Smart Plug

May 18, 2020

Equipment Class

DTS - Digital Transmission System