1 2 尺寸:64mmx89mmx8P 正 反 工艺:120g铜版纸双面印刷风琴折打开方式:从左到右 1 2 23 FCC Statement This device complies with part 15 of the FCC rules. Operation is subject to the following two cond itions: (1) this device may not cause harmful interference, and (2) this device must accept any inte rference received, including interference that may cause undesired operation. Caution: Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital d evice, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable prote ction against harmful interference in a residential installation. This equipment generates uses and c an radiate radio frequency energy and, if not installed and used in accordance with the instructions , may cause harmful interference to radio communications. However, there is no guarantee that int erference will not occur in a particular installation. If this equipment does cause harmful interferen ce to radio or television reception, which can be determined by turning the equipment off and on, t he user is encouraged to try to correct the interference by one or more of the following measures: ‐ Reorient or relocate the receiving antenna. ‐ Increase the separation between the equipment and receiver. ‐ Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. ‐Consult the dealer or an experienced radio/TV technician for help important announcement Radiation Exposure Statement The equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. During the operation of device a distance of 15 cm surrounding the device and 20 cm above the top surface of the device must be respected.
CONFIDENTIALITY REQUEST for Certification Service in USA Federal Communication Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21046 Date: 2020/04/20 TO WHOM IT MAY CONCERN Pursuant to Paragraphs §0.457 and 0.459 of the Commission’s Rules (47 C.F.R.) and Section §552(b)(4) of the Freedom of Information Act, we requests confidentiality for the following products: FCC ID Model name 2AVG2-G400 G400 For the product stated above, we request that the following information be held confidential; Exhibits Long-Term Confidentiality Short-Term Confidentiality Short-Term Confidentiality Days External Photos Internal Photos Block Diagram Schematics Test Setup Photos User’s Manual Parts List Tune Up Operational Descriptions The long-term confidentiality exhibits contain our trade secrets and proprietary information that could be of benefit to our competitors. The short-term confidentiality on the basis of ensuring that business sensitive information remains confidential until the actual marketing of our new device. If you have any questions, please feel free to contact me at the address shown below. Sincerely, Name: Yao Su/Manager Company: Shenzhen Shi Aiker Electronic Technology Co., Ltd. Address: 6th Floor, Building C, No. 9 East, Shangxue Technology Industrial City, Xinxue Community, Bantian Street, Longgang District, Shenzhen, China Phone: +86 0755 83770820 Fax: +86 0755 83770820 E-Mail: [email protected]
Shenzhen Shi Aiker Electronic Technology Co., Ltd. 6th Floor, Building C, No. 9 East, Shangxue Technology Industrial City, Xinxue Community, Bantian Street, Longgang District, Shenzhen, China Tel: +86 0755 83770820 Fax: +86 0755 83770820 Federal Communications Commission Authorization and Evaluation Division Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MD 21046 04/20/2020 To whom it may concern: We, Shenzhen Shi Aiker Electronic Technology Co., Ltd. the undersigned, hereby authorize Eurofins Product Service GmbH to act on our behalf in all matters relating to applications for equipment authorization FCC ID: 2AVG2-G400 including the signing of all documents related to these matters. Any and all acts carried out by Eurofins Product Service GmbH on our behalf shall have the same effect as acts of our own. We also hereby certify that no party to this application is subject to a denial of benefits, including FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 862. Sincerely, Name: Yao Su/Manager Company: Shenzhen Shi Aiker Electronic Technology Co., Ltd. Address: 6th Floor, Building C, No. 9 East, Shangxue Technology Industrial City, Xinxue Community, Bantian Street, Longgang District, Shenzhen, China Phone: +86 0755 83770820 Fax: +86 0755 83770820 E-Mail: [email protected]
GTS202003000184 Product Name: G400 Fast wireless charger Test Model No.: G400 EUT Constructional Details External Photo Fig.1 Fig.2 GTS202003000184 Fig.3 Fig.4 GTS202003000184 Fig.5 Fig.6
Label and Location Label and Location G400 Fast wireless charger Model No.: G400 FCC ID: 2AVG2-G400 This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
GTS202003000184 Product Name: G400 Fast wireless charger Test Model No.: G400 EUT Constructional Details Internal Photo Fig.1 Fig.2 Antenna GTS202003000184 Fig.3 Fig.4
Global United Technology Services Co., Ltd. No. 123-128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 1 of 7 RF Exposure Evaluation FCC ID; 2AVG2- G400 1 Measuring Standard KDB 680106 D01 RF Exposure Wireless Charging Apps v03 2 Requirements According to the item 5 of KDB 680106 D01v03: Inductive wireless power transfer applications that meet all of the following requirements are excluded from submitting an RF exposure evaluation. (1) Power transfer frequency is less than 1MHz. (2) Output power from each primary coil is less than or equal to 15 watts. (3) The transfer system includes only single primary and secondary coils. This includes charging systems that may have multiple primary coils and clients that are able to detect and allow coupling only between individual pairs of coils. (4) Client device is placed directly in contact with the transmitter. (5) Mobile exposure conditions only (portable exposure conditions are not covered by this exclusion). (6) The aggregate H-field strengths at 15 cm surrounding the device and 20 cm above the top surface from all simultaneous transmitting coils are demonstrated to be less than 50% of the MPE limit. Remark: Meet all the above requirements. Limits The criteria listed in the following table shall be used to evaluate the environment impact of human exposure to radio frequency (RF) radiation as specified in 1.1307(b) Limits for Maximum Permissible Exposure (MPE) Global United Technology Services Co., Ltd. No. 123-128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 2 of 7 3 Test Setup 4 Test Procedure 1) The RF exposure test was performed in anechoic chamber. 2) The measurement probe was placed at test distance (15 cm from all sides and 20 cm from the top) which is between the edge of the charger and the geometric center of probe. 3) The highest emission level was recorded and compared with limit as soon as measurement of each points (A, B, C, D, E) were completed. 4) The EUT was measured according to the dictates of KDB 680106 D01v03. Remark:The EUT’s test position A, B, C, D and E is valid for the E and H field measurements. 5 Equipment Approval Considerations The EUT does comply with KDB 680106 D01 as follow table. Requirements of KDB 680106 D01 Yes / No Description Power transfer frequency is less than 1 MHz Yes The device operate in the frequency range 110KHz~205KHz Output power from each primary coil is less than 15 watts Yes The maximum output power for each primary coil is 10W. The transfer system includes only single primary and secondary coils. This includes charging systems that may have multiple primary coils and clients that are able to detect and allow coupling only between individual pairs of coils. Yes The transfer system includes two primary coils but can only transmit between a pair of primary and secondary coils at the same time. Client device is placed directly in contact with the transmitter. Yes Client device is placed directly in contact with the transmitter. Mobile exposure conditions only (portable exposure conditions are not covered by this exclusion). Yes Mobile exposure conditions only The aggregate H-field strengths at 15 cm Yes The EUT H-field strengths at 15 cm Global United Technology Services Co., Ltd. No. 123-128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 3 of 7 surrounding the device and 20 cm above the top surface from all simultaneous transmitting coils are demonstrated to be less than 50% of the MPE limit. surrounding the device and 20 cm above the top surface from all simultaneous transmitting coils are demonstrated to be less than 50% of the MPE limit. 6 Description of the test mode Equipment under test was operated during the measurement under the following conditions: Charging and communication mode Test Modes: Mode 1 AC/DC Adapter (5V/2A) + EUT + Mobile Phone1 (Battery Status: <1%) Record Mode 2 AC/DC Adapter (5V/2A) + EUT + Mobile Phone1 (Battery Status: <50%) Record Mode 3 AC/DC Adapter (5V/2A) + EUT + Mobile Phone1 (Battery Status: 100%) Record Mode 4 AC/DC Adapter (9V/1.8A) + EUT + Mobile Phone1 (Battery Status: <1%) Pre-tested Mode 5 AC/DC Adapter (9V/1.8A) + EUT + Mobile Phone1 (Battery Status: <50%) Pre-tested Mode 6 AC/DC Adapter (9V/1.8A) + EUT + Mobile Phone1 (Battery Status: 100%) Pre-tested Note: All test modes were pre-tested, but we only recorded the worst case in this report. 7 Description of Support Units Follow auxiliary equipment(s) test with EUT that provided by the manufacturer or laboratory is listed as follow: Description Manufacturer Model Technical Parameters Certificate Provided by Adapter CHENYANG ELECTRONICS CD107 Input: 100-240V~, 50/60Hz, 0.5A Output: 5V2A / 9V1.8A CE/FCC laboratory / / / / / / / / / / / / / / / / / / Global United Technology Services Co., Ltd. No. 123-128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 4 of 7 8 Test Instruments list Test Equipment Manufacturer Model No. SN. Cal.Date (mm-dd-yy) Cal.Due date (mm-dd-yy) Exposure Level Tester Narda ELT-400 N-0231 June 29 2019 June 28 2020 Magnetic field probe 100cm 2 Narda ELT probe 100cm 2 M0675 June 29 2019 June 28 2020 9 Test Result E-Field Strength at 15 cm from the edges surrounding the EUT and 15cm from the top surface of the EUT Test port Chargin g Battery Level Frequency Range (MHz) Measured E-Field Strength Values (V/m) FCC E-Field Strength 50% Limits (V/m) FCC E-Field Strength Limits (V/m) Test Position A Test P…
Text truncated - open the document above for the full version.
Global United Technology Services Co., Ltd. Report No.: GTS202003000184F01 Authorized Signature: Robinson Lo Laboratory Manager This results shown in this test report refer only to the sample(s) tested, this test report cannot be reproduced, except in full, without prior written permission of the company. The report would be invalid without specific stamp of test institute and the signatures of compiler and approver. Page 1 of 19 TEST REPORT Applicant: Shenzhen Shi Aiker Electronic Technology Co., Ltd. Address of Applicant: 6th Floor, Building C, No. 9 East, Shangxue Technology Industrial City, Xinxue Community, Bantian Street, Longgang District, Shenzhen, China Manufacturer/Factory: Shenzhen Shi Aiker Electronic Technology Co., Ltd. Address of Manufacturer/Factory: 6th Floor, Building C, No. 9 East, Shangxue Technology Industrial City, Xinxue Community, Bantian Street, Longgang District, Shenzhen, China Equipment Under Test (EUT) Product Name: G400 Fast wireless charger Model No.: G400 FCC ID: 2AVG2-G400 Applicable standards: FCC CFR Title 47 Part 15 Subpart C Date of sample receipt: Dec. 02, 2019 Date of Test: Apr. 06, 2020- Apr. 16, 2020 Date of report issued: Apr. 16, 2020 Test Result : PASS * * In the configuration tested, the EUT complied with the standards specified above. Report No.: GTS202003000184F01 Global United Technology Services Co., Ltd. No. 123-128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 2 of 19 2 Version Version No. Date Description 00 Apr. 16, 2020 Original Prepared By: Date: Apr. 16, 2020 Project Engineer Check By: Date: Apr. 16, 2020 Reviewer Report No.: GTS202003000184F01 Global United Technology Services Co., Ltd. No. 123-128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 3 of 19 3 Contents Page 1 COVER PAGE ............................................................................................................................................ 1 2 VERSION .................................................................................................................................................. 2 3 CONTENTS .............................................................................................................................................. 3 4 TEST SUMMARY ..................................................................................................................................... 4 4.1 MEASUREMENT UNCERTAINTY ............................................................................................................ 4 5 GENERAL INFORMATION ...................................................................................................................... 5 5.1 GENERAL DESCRIPTION OF EUT ......................................................................................................... 5 5.2 TEST MODE ........................................................................................................................................ 5 5.3 DESCRIPTION OF SUPPORT UNITS ....................................................................................................... 5 5.4 DEVIATION FROM STANDARDS ............................................................................................................. 6 5.5 ABNORMALITIES FROM STANDARD CONDITIONS ................................................................................... 6 5.6 TEST FACILITY .................................................................................................................................... 6 5.7 TEST LOCATION ................................................................................................................................. 6 5.8 OTHER INFORMATION REQUESTED BY THE CUSTOMER ......................................................................... 6 6 TEST INSTRUMENTS LIST ..................................................................................................................... 7 7 TEST RESULTS AND MEASUREMENT DATA ...................................................................................... 9 7.1 ANTENNA REQUIREMENT: .................................................................................................................... 9 7.2 CONDUCTED EMISSIONS ................................................................................................................... 10 7.3 RADIATED EMISSION ......................................................................................................................... 13 7.4 20DB OCCUPY BANDWIDTH .............................................................................................................. 18 8 TEST SETUP PHOTO ............................................................................................................................ 19 9 EUT CONSTRUCTIONAL DETAILS ..................................................................................................... 19 Report No.: GTS202003000184F01 Global United Technology Services Co., Ltd. No. 123-128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 4 of 19 4 Test Summary Test Item Section in CFR 47 Result Antenna requirement 15.203 Pass AC Power Line Conducted Emission 15.207 Pass Radiated Emission 15.209(a)(f) Pass 20dB Bandwidth 15.215 Pass Pass: The EUT complies with the essential requirements in the standard. 4.1 Measurement Uncertainty Test Item Frequency Range Measurement Uncertainty Notes Radiated Emission 30MHz-200MHz 3.8039dB (1) Radiated Emission 200MHz-1GHz 3.9679dB (1) Radiated Emission 1GHz-18GHz 4.29dB (1) Radiated Emission 18GHz-…
Text truncated - open the document above for the full version.
GTS202003000184 Global United Technology Services Co., Ltd. No. 123-128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 1 of 2 Product Name: G400 Fast wireless charger Test Model No.: G400 Test Setup Photo Radiated Emission GTS202003000184 Global United Technology Services Co., Ltd. No. 123-128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 2 of 2 Conducted Emission ------End------
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 0.11 MHz - 0.205 MHz | - |

Multi-in-one cooling wireless charger
Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz
Magnetic Charger
Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz