FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

ยฉ 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. DP AUDIO VIDEO LLC/
  3. 2AVRVCTP100LG

2AVRVCTP100LGProfessional Wireless Thermal Printer

DP AUDIO VIDEO LLC
Professional Wireless Thermal Printer - FCC ID 2AVRVCTP100LG - DP AUDIO VIDEO LLC
Click to zoom

Application Details

Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Date of Grant
Jan 08, 2024
Application Purpose
Original Equipment
Date of Application
Jan 08, 2024
Equipment Note
Professional Wireless Thermal Printer
Frequency Range
2402.00000000 - 2480.00000000
Company
DP AUDIO VIDEO LLC
Country
United States

Documents & Files

Select a file to view

Users Manual

โ†—

Attestation Statements

โ†—
โ†—

Cover Letter(s)

โ†—
โ†—

External Photos

โ†—

ID Label/Location Info

โ†—

Internal Photos

โ†—

RF Exposure Info

โ†—

Test Report

โ†—
โ†—
โ†—

Test Setup Photos

โ†—

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Attestation Statements

DP AUDIO VIDEO LLC U.S. Agent Designation for Service of Process (Applicant and U.S. Agent are Separate Parties) TO: Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046, USA ATTENTION: FCC Certification โ€“ Section 2.911(d)(7) Information Designated U.S. Agent Company Name: DP AUDIO VIDEO LLC FRN: 0029264256 Contact Name: Roy Ryan Address: 1001 Gayley Avenue P.O. Box 24857, Los Angeles, California United States 90024 Telephone No: 001-3109661133 Email: [email protected] This letter is to confirm that we (โ€œthe Designated U.S. Agent) have accepted the responsibility to act as the Designated U.S. Agent for Service of Process as required by secti on 47 CFR 2.911(d)(7) on behalf of the Applicant noted below. U.S. Agent Signature: Date: Signed by (Printed Name/Title): This Agreement is valid until: The Applicant acknowledges that they must maintain an agent for no less t han one year after t erminating all marketing and importation OR the conclusion of any Commission-related proceeding involving the equipment. The applicant further acknowledges their responsibility to inform the FCC whenever the Designated U.S. Agent information above changes. Applicant Company name: DP AUDIO VIDEO LLC Grantee Code: 2AVRV FCC ID: 2AVRVCTP100LG Contact Name: Roy Ryan Address: 1001 Gayley Avenue P.O. Box 24857, Los Angeles, California United States 90024 Telephone No: 001-3109661133 Email: [email protected] Applicant Signature: Date: 2024-01-04 Signed by (Printed Name/Title): Roy Ryan/ Manager

Attestation Statements

(DP AUDIO VIDEO LLC) (2024.01.03) Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: Attestation Statements Part 2.911(d)(5)(i) request for (FCC ID: 2AVRVCTP100LG) [DP AUDIO VIDEO LLC] (โ€œthe applicantโ€) certifies that the equipment for which authorization is sought is not โ€œcoveredโ€ equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. Sincerely, (Applicant signature) (Applicant printed name) Roy Ryan (DP AUDIO VIDEO LLC) (2024.01.03) Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: Attestation Statements Part 2.911(d)(5)(ii) request for (FCC ID: 2AVRVCTP100LG) [DP AUDIO VIDEO LLC] (โ€œthe applicantโ€) certifies that, as of th e date of th e filin g of the application, the applicant is not identified on the Covered List as an entity producing โ€œcoveredโ€ equipment. Sincerely, (Applicant signature) (Applicant printed name) Roy Ryan

Cover Letter(s)

DP AUDIO VIDEO LLC 2024.01.03 Eurofins Electrical and Electronic Testing NA, Inc. 914 W. Patapsco Avenue Baltimore, MD 21230 USA RE: CONFIDENTIALITY REQUEST FOR EUT NAME: Professional Wireless Thermal Printer Trademark: Core Innovations MODEL : CTP100LG FCC ID: 2AVRVCTP100LG To Whom It May Concern: This letter serves as an official request for confidentiality under sections 0.457 and 0.459 of CFR 47. We have requested that the - Block Diagram - Schematics - Operational Description required to be submitted with this application be permanently withheld from public review. The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these materials may be harmful to the applicant and provide unjustified benefits to its competitors. Please contact me if there is any information you may need. Sincerely, Clientโ€™s signature: Clientโ€™s name / title : Roy Ryan/Manager Contact information / address: 1001 Gayley Avenue P.O. Box 24857, Los Angeles, California United States 90024

Cover Letter(s)

DP AUDIO VIDEO LLC 2024.01.03 Eurofins Electrical and Electronic Testing NA, Inc. 914 W. Patapsco Avenue Baltimore, MD 21230 USA RE: LETTER OF AGENT AUTHORIZATION To Whom It May Concern: We, the undersigned, hereby authorize Shenzhen BCTC Testing Co., Ltd to act on our behalf in all matters relating to application for equipment authorization, including the signing of all documents relating to these matters. We also hereby certify that no party to the application authorized hereunder is subject to the denial of benefits, including FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C.853(a). This agreement expires one year from the current date. Sincerely, Clientโ€™s signature: Clientโ€™s name / title : Roy Ryan/Manager Contact information / address: 1001 Gayley Avenue P.O. Box 24857, Los Angeles, California United States 90024

External Photos

External Photos

Internal Photos

Internal Photos Antenna

RF Exposure Info

RF EXPOSURE EVALUATION METHOD FCC ID: 2AVRVCTP100LG Applicable standard๏ผš In accordance with FCC 47 CFR part 2 (2.1093) this device has been defined as a portable device which is defined as a transmitting device designed to be used so that the radiating structure(s) of the device is/are within 20 centimeters of the body of the user. Portable devices must be evaluated using the specified in FCC 47 CFR part 2 (2.1093) and ANSI/IEEEC95.1-1992. and had been tested in accordance with the measurement methods and procedures specified in IEEE 1528-2003. Per FCC KDB 447498 D01 v06, the 1-g and 10-g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation distances s 50 mm are determined by: SAR Test Exclusion Thresholds for 100 MHz โ€“ 6 GHz and โ‰ค 50 mm Approximate SAR Test Exclusion Power Thresholds at Selected Frequencies and Test Separation Distances are illustrated in the following Table. The 1-g and 10-g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation distances โ‰ค 50 mm are determined by: [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance, mm)] ยท [โˆšf(GHz)] โ‰ค 3.0 for 1-g SAR and โ‰ค 7.5 for 10-g extremity SAR,where f(GHz) is the RF channel transmit frequency in GHz Power and distance are rounded to the nearest mW and mm before calculation The result is rounded to one decimal place for comparison The test exclusions are applicable only when the minimum test separation distance is โ‰ค 50 mm and for transmission frequencies between 100 MHz and 6 GHz. When the minimum test separation distance is < 5 mm, a distance of 5 mm is applied to determine SAR test exclusion. BLE Mode Frequency (MHz) Conducted Power (dBm) Limit (dBm) Verdict GFSK 2402 4.78 30 Pass 2440 4.72 30 Pass 2480 3.69 30 Pass max possible output power (PK,conducted)๏ผš5ยฑ1dBm -4.73dBi logarithmic terms convert to numeric result is nearly 0.337 6dBm=3.98mW 2402MHz [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance,mm)] ยท [โˆšf(GHz)]= 3.98/5*โˆš2.402=1.23โ‰ค3.0 2440MHz [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance,mm)] ยท [โˆšf(GHz)]=3.98/5*โˆš2.44=1.24โ‰ค3.0 2480MHz [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance,mm)] ยท [โˆšf(GHz)]= 3.98/5*โˆš2.48=1.25โ‰ค3.0 BT Condition Mode Frequency (MHz) Conducted Power (dBm) Limit (dBm) Verdict NVNT 1-DH1 2402 4.70 21 Pass NVNT 1-DH1 2441 4.64 21 Pass NVNT 1-DH1 2480 3.70 21 Pass NVNT 2-DH1 2402 4.01 21 Pass NVNT 2-DH1 2441 3.99 21 Pass NVNT 2-DH1 2480 2.99 21 Pass NVNT 3-DH1 2402 4.37 21 Pass NVNT 3-DH1 2441 4.28 21 Pass NVNT 3-DH1 2480 3.25 21 Pass max possible output power (PK,conducted)๏ผš5ยฑ1dBm -4.73dBi logarithmic terms convert to numeric result is nearly 0.337 6dBm=3.98mW 2402MHz [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance,mm)] ยท [โˆšf(GHz)]= 3.98/5*โˆš2.402=1.23โ‰ค3.0 2441MHz [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance,mm)] ยท [โˆšf(GHz)]=3.98/5*โˆš2.441=1.24โ‰ค3.0 2480MHz [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance,mm)] ยท [โˆšf(GHz)]= 3.98/5*โˆš2.48=1.25โ‰ค3.0 Conclusion: 1. [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance, mm)] * [โˆšf(GHz)] < 3.0. 2. SAR Test Exclusion Thresholds is 3.0 for separation distance 5mm. Therefore, SAR test is not required.

Test Report

NOTE:1.Thereportisinvalidwhenthereisnotheapproversignatureandthespecialstampfortestreport.2.Thetestreport shallnotbereproducedexceptinfullwithoutpriorwrittenpermissionofthecompany.3.Thereportcopyisinvalidwhenthereis nothespecialstampfortestrepor.4.Thealteredreportisinvalid.5.Theentrusttestisresponsibilityforthereceivedsample only Kehu-Morlab TestLaboratory XIAMENMORLABCOMMUNICATIONSTECHNOLOGYCo.,Ltd. Unit101,No.1732GangzhongRoad,XiamenArea,PilotFreeTradeZone(Fujian),P.R.China Tel:+865925612050 Fax:+865925612095 REPORTNo.๏ผšXM20060056W03 TESTREPORT MANUFACTURER:XiamenIleadTekCo.,Ltd. PRODUCTNAME:2.4G_IFA MODELNAME:ANT001 BRANDNAME:PeriPage STANDARD(S): IEEE-149-1979-R2003 RECEIPTDATE: 2020.7.20 TESTDATE:2020.7.20 ISSUEDATE:2020.7.20 Editedby: Pengfuwei(Testengineer) Reviewby: ElvisWang(Auditor) Approvedby: AnneLiu(Supervisor) Page 1 0f11 Kehu-Morlab TestLaboratory XIAMENMORLABCOMMUNICATIONSTECHNOLOGYCo.,Ltd. Unit101,No.1732GangzhongRoad,XiamenArea,PilotFreeTradeZone(Fujian),P.R.China Tel:+865925612050 Fax:+865925612095 REPORTNo.๏ผšXM20060056W03 DIRECTORY 1.Technicalinformationยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท3 1.1EquipmentUnderTest(EUT)Descriptionยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท3 1.2AntennalayoutandImplementation:ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท4 1.3TestingLaboratoryInformationยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท5 1.4TestStandardandResults ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 5 1.5TestEquipmentandSoftware ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 6 1.6EnvironmentalConditions ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 6 2.Testresults ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 7 2.1AntennaGain,Efficiency,Pattern ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 7 AnnexAphotographsoftestsetupยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท11 ChangeHistory VersionDateReasonforchange 1.02020-07-20Firstedition Page20f11 Kehu-Morlab TestLaboratory XIAMENMORLABCOMMUNICATIONSTECHNOLOGYCo.,Ltd. Unit101,No.1732GangzhongRoad,XiamenArea,PilotFreeTradeZone(Fujian),P.R.China Tel:+865925612050 Fax:+865925612095 REPORTNo.๏ผšXM20060056W03 1.Technicalinformation 1.1EquipmentUnderTest(EUT)Description EUTType................................: N/A SampleNo.............................:N/A HardwareVersion.................:N/A SoftwareVersion..................:N/A Applicant................................:XiamenIleadTekCo.,Ltd. Manufacturer.........................:XiamenIleadTekCo.,Ltd. StandardandFrequency Band.........................................: 2400MHz-2483.5MHz TestChannel..........................:N/A ModulationType...................:N/A AntennaType........................:PCBon-board AntennaConnector.............:N/A PowerSupply........................:N/A Note1:Foramoredetaileddescription,pleaserefertoSpecificationorUserโ€™sManualsuppliedby theapplicantand/ormanufacturer. Page30f11 Kehu-Morlab TestLaboratory XIAMENMORLABCOMMUNICATIONSTECHNOLOGYCo.,Ltd. Unit101,No.1732GangzhongRoad,XiamenArea,PilotFreeTradeZone(Fujian),P.R.China Tel:+865925612050 Fax:+865925612095 REPORTNo.๏ผšXM20060056W03 1.2AntennalayoutandImplementation: Figure1:AntennaDimensions L1 3.94mm L2 2.70mm L3 5.00mm L4 2.64mm L5 2.00mm L6 4.90mm W1 0.90mm W2 0.50mm D1 0.50mm D2 0.30mm D3 0.30mm D4 0.50mm D5 1.40mm D6 1.70mm Table1:AntennaDimensions Page40f11 Kehu-Morlab TestLaboratory XIAMENMORLABCOMMUNICATIONSTECHNOLOGYCo.,Ltd. Unit101,No.1732GangzhongRoad,XiamenArea,PilotFreeTradeZone(Fujian),P.R.China Tel:+865925612050 Fax:+865925612095 REPORTNo.๏ผšXM20060056W03 1.3TestingLaboratoryInformation 1.IdentificationoftheResponsibleTestingLaboratory LaboratoryName: Kehu-MorlabTestLaboratory LaboratoryAddress:Unit101,No.1732GangzhongRoad,XiamenArea,PilotFree TradeZone(Fujian)P.R.China Telephone: +865925612050 Facsimile: +865925612095 2.IdentificationoftheResponsibleTestingLocation 1.4TestStandardandResults Thereportistestedaccordingtothefollowingstandard: NoStandardNo.StandardName 1 IEEE-149-1979-R2003 StandardTestProceduresforAntennas Testitemsandtheresultsareasbellow: NoTestFrequencyBandTestItemResult 12400MHz ๏ฝž 2483.5MHzGainN/A 22400MHz ๏ฝž 2483.5MHzEfficiencyN/A 32400MHz ๏ฝž 2483.5MHzPatternN/A Name: Kehu-MorlabTestLaboratory Address: Unit101,No.1732GangzhongRoad,XiamenArea,PilotFree TradeZone(Fujian)P.R.China Page50f11 Kehu-Morlab TestLaboratory XIAMENMORLABCOMMUNICATIONSTECHNOLOGYCo.,Ltd. Unit101,No.1732GangzhongRoad,XiamenArea,PilotFreeTradeZone(Fujian),P.R.China Tel:+865925612050 Fax:+865925612095 REPORTNo.๏ผšXM20060056W03 1.5TestEquipmentandSoftware NoEquipmentType๏ผˆVersion๏ผ‰SupplierCal.DueDate 1 OTATestsystem EMQuest1.11Build 7570 ETS/U.S.A / 2 NetworkAnalyzerAglientE5071C keysight/U.S. A 2021-03-11 3 FullyAnechoic Chamber 4mร—4mร—4mETS/U.S.A2022-05-31 1.6EnvironmentalConditions Recordtherangeoftestenvironmentduringthetest: Ambienttemperature(ยฐC):15-35 Relativehumidity(%):30-60 Atmospherepressure(kPa):86-106 Page60f11 Kehu-Morlab TestLaboratory XIAMENMORLABCOMMUNICATIONSTECHNOLOGYCo.,Ltd. Unit101,No.1732GangzhongRoad,XiamenArea,PilotFreeTradeZone(Fujian),P.R.China Tel:+865925612050 Fax:+865925612095 REPORTNo.๏ผšXM20060056W03 2.Testresults 2.1AntennaGain,Efficiency,Pattern 2.1.1TestProcedure๏ผš ThemeasuredEUTrotates0~180degreesaroundtheฮธaxis.Themeasured antennaissampledalongtheฮฆaxisof0~360from15degreestoameasuringstep,and themeasuredvalueisreadautomatically.Theantennagain,efficiency,patternis measured 2.1.2TestResult๏ผš MaxGain:-4.73dBi No. Test Frequency ๏ผˆMHz๏ผ‰ GainTest Value ๏ผˆdBi๏ผ‰ Efficiency testvalue ๏ผˆ%๏ผ‰ Antenna pattern Result 12400-4.8015.56 Phi=0 Phi=90 Theta=90 N/A 22402-4.8915.66N/A 32404-4.9015.52N/A 42406-4.7315.49N/A 52408-4.7915.44N/A Master computer PathSwitcher NetworkAnalyzer measured antenna Fully Anechoic Chambโ€ฆ

Text truncated - open the document above for the full version.

Test Report

No.๏ผšBCTC/RF-EMC-005 Page: 1 of 85 Edition๏ผšB.1 TEST REPORT Shenzhen BCTC Testing Co., Ltd. Report No.: BCTC2312786554-1E Applicant: DP AUDIO VIDEO LLC Product Name: Professional Wireless Thermal Printer Test Model: CTP100LG Tested Date: 2023-12-07 to 2023-12-19 Issued Date: 2023-12-19 Report No.: BCTC2312786554-1E No.๏ผšBCTC/RF-EMC-005 Page: 2 of 85 Edition๏ผšB.1 FCC ID:2AVRVCTP100LG The test report is effective only with both signature and specialized stamp.This result(s) shown in this report refer only to the sample(s) tested. Without written approval of Shenzhen BCTC Testing Co., Ltd, this report canโ€™t be reproduced except in full.The tested sample(s) and the sample information are provided by the client. Product Name: Professional Wireless Thermal Printer Trademark: Core Innovations Model/Type Reference: CTP100LG Prepared For: DP AUDIO VIDEO LLC Address: 1001 Gayley Avenue P.O. Box 24857, Los Angeles, California United States 90024 Manufacturer: GUANGDONG KAIGE TECHNOLOGY CO., LTD Address: XiuShui Road, Laimei Industrial Park, Fengxiang Street, Chenghai District, Shantou, Guangdong, China Prepared By: Shenzhen BCTC Testing Co., Ltd. Address: 1-2/F., Building B, Pengzhou Industrial Park, No.158, Fuyuan 1st Road, Zhancheng, Fuhai Subdistrict, Bao'an District, Shenzhen, Guangdong, China Sample Received Date: 2023-12-07 Sample Tested Date: 2023-12-07 to 2023-12-19 Issue Date: 2023-12-19 Report No.: BCTC2312786554-1E Test Standards: FCC Part15.247 ANSI C63.10-2013 Test Results: PASS Remark: This is Bluetooth Classic radio test report. Tested by: Approved by: Kelsey Tan/ Project Handler Zero Zhou/Reviewer Report No.: BCTC2312786554-1E No.๏ผšBCTC/RF-EMC-005 Page: 3 of 85 Edition๏ผšB.1 Table Of Content Test Report Declaration Page 1. Version .................................................................................................................. 5 2. Test Summary ....................................................................................................... 6 3. Measurement Uncertainty ..................................................................................... 7 4. Product Information And Test Setup ..................................................................... 8 4.1 Product Information ............................................................................................... 8 4.2 Test Setup Configuration ...................................................................................... 9 4.3 Support Equipment ............................................................................................... 9 4.4 Channel List ........................................................................................................ 10 4.5 Test Mode ........................................................................................................... 10 4.6 Table Of Parameters Of Text Software Setting ................................................... 10 5. Test Facility And Test Instrument Used ............................................................... 11 5.1 Test Facility ......................................................................................................... 11 5.2 Test Instrument Used .......................................................................................... 11 6. Conducted Emissions .......................................................................................... 13 6.1 Block Diagram Of Test Setup .............................................................................. 13 6.2 Limit .................................................................................................................... 13 6.3 Test procedure .................................................................................................... 13 6.4 EUT operating Conditions ................................................................................... 13 6.5 Test Result .......................................................................................................... 14 7. Radiated emissions ............................................................................................. 16 7.1 Block Diagram Of Test Setup .............................................................................. 16 7.2 Limit .................................................................................................................... 17 7.3 Test procedure .................................................................................................... 18 7.4 EUT operating Conditions ................................................................................... 19 7.5 Test Result .......................................................................................................... 19 8. Radiated Band Emission Measurement And Restricted Bands Of Operation ..... 25 8.1 Block Diagram Of Test Setup .............................................................................. 25 8.2 Limit .................................................................................................................... 25 8.3 Test procedure .................................................................................................... 26 8.4 EUT operating Conditions ................................................................................... 26 8.5 Test Result .......................................................................................................... 27 9. Spurious RF Conducted Emissions ..................................................................... 28 9.1 Block Diagram Of Test Setup .............................................................................. 28 9.2 Limit .................................................................................................................... 28 9.3 Test procedure .................................................................................................... 28 9.4 Test Result .........................................................................โ€ฆ

Text truncated - open the document above for the full version.

Test Report

Report No.: BCTC2312786554-1E No.๏ผšBCTC/RF-EMC-005 Page: 71 of 85 Edition๏ผšB.1 14. Dwell Time 14.1 Block Diagram Of Test Setup 14.2 Limit Frequency hopping systems in the 2400-2483.5 MHz band shall use at least 15 channels. The average time of occupancy on any channel shall not be greater than 0.4 seconds within a period of 0.4 seconds multiplied by the number of hopping channels employed. Frequency hopping systems may avoid or suppress transmissions on a particular hopping frequency provided that a minimum of 15 channels are used. 14.3 Test procedure 1. Remove the antenna from the EUT and then connect a low RF cable from the antenna port to the spectrum. 2. Set spectrum analyzer span = 0. Centred on a hopping channel; 3. Set RBW = 1MHz and VBW = 3MHz.Sweep = as necessary to capture the entire dwell time per hopping channel. Set the EUT for DH5, DH3 and DH1 packet transmitting. 4. Use the marker-delta function to determine the dwell time. If this value varies with different modes of operation (e.g.. data rate. modulation format. etc.). repeat this test for each variation. The limit is specified in one of the subparagraphs of this Section. Submit this plot(s). 14.4 Test Result Mode Frequency (MHz) Pulse Time (ms) Total Dwell Time (ms) Burst Count Period Time (ms) Limit (ms) Verdict 1-DH1 2441 0.381 35.814 94 31600 400 Pass 1-DH3 2441 1.638 126.126 77 31600 400 Pass 1-DH5 2441 2.885 126.94 44 31600 400 Pass 2-DH1 2441 0.391 36.363 93 31600 400 Pass 2-DH3 2441 1.643 106.795 65 31600 400 Pass 2-DH5 2441 2.891 112.749 39 31600 400 Pass 3-DH1 2441 0.391 43.792 112 31600 400 Pass 3-DH3 2441 1.641 100.101 61 31600 400 Pass 3-DH5 2441 2.892 144.6 50 31600 400 Pass Note: Total Dwell Time (ms) = Pulse Time (ms)*Burst Count Report No.: BCTC2312786554-1E No.๏ผšBCTC/RF-EMC-005 Page: 72 of 85 Edition๏ผšB.1 Test Graphs Dwell NVNT 1-DH1 2441MHz One Burst Dwell NVNT 1-DH1 2441MHz Accumulated Report No.: BCTC2312786554-1E No.๏ผšBCTC/RF-EMC-005 Page: 73 of 85 Edition๏ผšB.1 Dwell NVNT 1-DH3 2441MHz One Burst Dwell NVNT 1-DH3 2441MHz Accumulated Report No.: BCTC2312786554-1E No.๏ผšBCTC/RF-EMC-005 Page: 74 of 85 Edition๏ผšB.1 Dwell NVNT 1-DH5 2441MHz One Burst Dwell NVNT 1-DH5 2441MHz Accumulated Report No.: BCTC2312786554-1E No.๏ผšBCTC/RF-EMC-005 Page: 75 of 85 Edition๏ผšB.1 Dwell NVNT 2-DH1 2441MHz One Burst Dwell NVNT 2-DH1 2441MHz Accumulated Report No.: BCTC2312786554-1E No.๏ผšBCTC/RF-EMC-005 Page: 76 of 85 Edition๏ผšB.1 Dwell NVNT 2-DH3 2441MHz One Burst Dwell NVNT 2-DH3 2441MHz Accumulated Report No.: BCTC2312786554-1E No.๏ผšBCTC/RF-EMC-005 Page: 77 of 85 Edition๏ผšB.1 Dwell NVNT 2-DH5 2441MHz One Burst Dwell NVNT 2-DH5 2441MHz Accumulated Report No.: BCTC2312786554-1E No.๏ผšBCTC/RF-EMC-005 Page: 78 of 85 Edition๏ผšB.1 Dwell NVNT 3-DH1 2441MHz One Burst Dwell NVNT 3-DH1 2441MHz Accumulated Report No.: BCTC2312786554-1E No.๏ผšBCTC/RF-EMC-005 Page: 79 of 85 Edition๏ผšB.1 Dwell NVNT 3-DH3 2441MHz One Burst Dwell NVNT 3-DH3 2441MHz Accumulated Report No.: BCTC2312786554-1E No.๏ผšBCTC/RF-EMC-005 Page: 80 of 85 Edition๏ผšB.1 Dwell NVNT 3-DH5 2441MHz One Burst Dwell NVNT 3-DH5 2441MHz Accumulated Report No.: BCTC2312786554-1E No.๏ผšBCTC/RF-EMC-005 Page: 81 of 85 Edition๏ผšB.1 15. Antenna Requirement 15.1 Limit 15.203 requirement: For intentional device, according to 15.203: an intentional radiator shall be designed to ensure that no antenna other than that furnished by the responsible party shall be used with the device. 15.2 Test Result The EUT antenna is Internal antenna, fulfill the requirement of this section. Report No.: BCTC2312786554-1E No.๏ผšBCTC/RF-EMC-005 Page: 82 of 85 Edition๏ผšB.1 16. EUT Photographs EUT Photo NOTE: Appendix-Photographs Of EUT Constructional Details Report No.: BCTC2312786554-1E No.๏ผšBCTC/RF-EMC-005 Page: 83 of 85 Edition๏ผšB.1 17. EUT Test Setup Photographs Conducted emissions Report No.: BCTC2312786554-1E No.๏ผšBCTC/RF-EMC-005 Page: 84 of 85 Edition๏ผšB.1 Radiated Measurement Photos Report No.: BCTC2312786554-1E No.๏ผšBCTC/RF-EMC-005 Page: 85 of 85 Edition๏ผšB.1 STATEMENT 1. The equipment lists are traceable to the national reference standards. 2. The test report can not be partially copied unless prior written approval is issued from our lab. 3. The test report is invalid without the "special seal for inspection and testing". 4. The test report is invalid without the signature of the approver. 5. The test process and test result is only related to the Unit Under Test. 6. Sample information is provided by the client and the laboratory is not responsible for its authenticity. 7. The quality system of our laboratory is in accordance with ISO/IEC17025. 8. If there is any objection to this test report, the client should inform issuing laboratory within 15 days from the date of receiving test report. Address: 1-2/F., Building B, Pengzhou Industrial Park, No.158, Fuyuan 1st Road, Zhancheng, Fuhai Subdistrict, Bao'an District, Shenzhen, Guangdong, China TEL: 400-788-9558 P. C.: 518103 FAX: 0755-33229357 Website: http://www.chnbctc.com E-Mail: [email protected] โ€ปโ€ปโ€ปโ€ปโ€ป END โ€ปโ€ปโ€ปโ€ปโ€ป

Test Setup Photos

Report No.: BCTC2312786554-1E No.๏ผšBCTC/RF-EMC-005 Page: 83 of 85 Edition๏ผšB.1 17. EUT Test Setup Photographs Conducted emissions Report No.: BCTC2312786554-1E No.๏ผšBCTC/RF-EMC-005 Page: 84 of 85 Edition๏ผšB.1 Radiated Measurement Photos

Contact Information

Applicant

Roy Ryan
[email protected]001-3109661133Fax: 001-310-966-1134

Test Firm

Shenzhen BCTC Testing Co., Ltd.Sally He
[email protected]15999690624

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz2.95 mW
Confidentiality
Long Term
Grant Notes
Output Power listed is conducted. The antenna(s) used for this transmitter must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures.

Other Applications from DP AUDIO VIDEO LLC

2AVRVBS500HT

Hot Tub & Pool Bluetooth Floating Speaker

Sep 10, 2024

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
32inch Rollable Smart Touchscreen TV - FCC ID 2AVRV-DG3200 - DP AUDIO VIDEO LLC
2AVRV-DG3200

32inch Rollable Smart Touchscreen TV

Jul 21, 2024

Equipment Class

DTS - Digital Transmission System
Portable Karaoke Machine - FCC ID 2AVRVKRMIC200 - DP AUDIO VIDEO LLC
2AVRVKRMIC200

Portable Karaoke Machine

Jul 10, 2024

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
AIO computer - FCC ID 2AVRVCC2400 - DP AUDIO VIDEO LLC
2AVRVCC2400

AIO computer

Jan 16, 2024

Equipment Class

DTS - Digital Transmission System
Inflatable Car Pool Speaker - FCC ID 2AVRVPKCS120 - DP AUDIO VIDEO LLC
2AVRVPKCS120

Inflatable Car Pool Speaker

Sep 23, 2023

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter