FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Liquipel Protection LLC/
  3. 2AVV6-827288

2AVV6-8272883 in 1 Wireless charger

Liquipel Protection LLC
3 in 1 Wireless charger - FCC ID 2AVV6-827288 - Liquipel Protection LLC
Click to zoom

Application Details

Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz
Date of Grant
Apr 07, 2026
Application Purpose
Original Equipment
Equipment Note
3 in 1 Wireless charger
Frequency Range
0.11010000 - 0.20500000
Company
Liquipel Protection LLC
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗
↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

FCC Statement Thisdevicecomplieswithpart15oftheFCCRules.Operationissubjecttothefollowingtwo conditions:(1)Thisdevicemaynotcauseharmfulinterference,and(2)thisdevicemustaccept anyinterferencereceived,includinginterferencethatmaycauseundesiredoperation. Note:ThisequipmenthasbeentestedandfoundtocomplywiththelimitsforaClassBdigital device,pursuanttopart15oftheFCCRules.Theselimitsaredesignedtoprovidereasonable protectionagainstharmfulinterferenceinaresidentialinstallation.Thisequipmentgenerates, usesandcanradiateradiofrequencyenergyand,ifnotinstalledandusedinaccordancewiththe instructions,maycauseharmfulinterferencetoradiocommunications.However,thereisno guaranteethatinterferencewillnotoccurinaparticularinstallation.Ifthisequipmentdoes causeharmfulinterferencetoradioortelevisionreception,whichcanbedeterminedbyturning theequipmentoffandon,theuserisencouragedtotrytocorrecttheinterferencebyoneor moreofthefollowingmeasures: Reorientorrelocatethereceivingantenna. Increasetheseparationbetweentheequipmentandreceiver. Connecttheequipmentintoanoutletonacircuitdifferentfromthattowhichthereceiveris connected. Consultthedealeroranexperiencedradio/TVtechnicianforhelp. Note:TheGranteeisnotresponsibleforanychangesormodificationsnotexpresslyapprovedby thepartyresponsibleforcompliance.suchmodificationscouldvoidtheuser'sauthorityto operatetheequipment. ThedevicehasbeenevaluatedtomeetgeneralRFexposurerequirement. TomaintaincompliancewithFCC'sRFexposureguidelines,thedistancemustbeatleast20cm betweentheradiatorandyourbody,andfullysupportedbytheoperatingandinstallation configurationsofthetransmitteranditsantenna(s).

Attestation Statements

LiquipelProtectionLLC Address:19800MacArthurBlvd.Suite300,Irvine Date:2026-04-02 FederalCommunicationsCommission AuthorizationandEvaluationDivision 7435OaklandMillsRoad Columbia,MD21046 Ref:AttestationStatementsPart2.911(d)(7)Filing SUBJECT:FCCApplicationforFCCID:2AVV6-827288 FRN:0029326568 (“LiquipelProtectionLLC”)certifiesthat,asofthedateofthefilingoftheapplication,Liquipel ProtectionLLCisourdesignatedU.S.agentforserviceofprocessfortheabovereferenced FCCID.(“LiquipelProtectionLLC”)acceptstomaintainanagentfornolessthanoneyear afterthegranteehasterminatedallmarketingandimportationortheconclusionofany Commission-relatedproceedinginvolvingtheequipment. LiquipelProtectionLLCaccepts,asofthedateofthefilingoftheapplication,theobligationof thedesignatedU.S.agentforserviceofprocessfortheabovereferencedFCCID. DesignatedU.S.AgentInformation: Name:LiquipelProtectionLLC Address:19800MacArthurBlvd.Suite300,Irvine FRN:0029326568 ContactPerson:Linguichu Tel.:13802904065 Email:[email protected] Sincerely, Signedonbehalfof(LiquipelProtection LLC) SignedonbehalfofLiquipelProtectionLLC Name:LinguichuName:Linguichu Title:ManagerTitle:Manager Date:2026-04-02Date:2026-04-02

Attestation Statements

Rev1/26/2023 (LiquipelProtectionLLC) FederalCommunicationsCommission AuthorizationandEvaluationDivision 7435OaklandMillsRoad Columbia,MD21046 USA Date:3-30-2026 Ref:AttestationStatementsPart2.911(d)(5)(i)Filing FCCID:2AVV6-827288 (“LiquipelProtectionLLC”)certifiesthattheequipmentforwhichauthorizationissoughtisnot“covered” equipmentprohibitedfromreceivinganequipmentauthorizationpursuanttosection2.903oftheFCC rules. (“LiquipelProtectionLLC”)certifiesthattheequipmentforwhichauthorizationissoughtdoesnot includecybersecurityoranti-virussoftwareproducedorprovidedbyKasperskyLab,Inc.oranyofits successorsandassignees,includingequipmentwithintegratedKasperskyLab,Inc.(oranyofits successorsandassignees)cybersecurityoranti-virussoftwarepursuanttoDA-24-886andKDB986446 D01CoveredEquipmentGuidancesectionB(2a). Deviceisinherentlycompliantbasedonhardwarelimitationsorsoftwarecontrols. or ASoftwareBillofMaterials(SBOM)isprovidedtotheTCBforreview,and Theend-userorthirdpartiescannotinstalladditionalsoftwareonthisdevice. Sincerely, (Applicantsignature): (Applicantprintedname):Linguichu Rev1/26/2023 (LiquipelProtectionLLC) FederalCommunicationsCommission AuthorizationandEvaluationDivision 7435OaklandMillsRoad Columbia,MD21046 USA Date:3-30-2026 Ref:AttestationStatementsPart2.911(d)(5)(ii)Filing FCCID:2AVV6-827288 (“LiquipelProtectionLLC”)certifiesthat,asofthedateofthefilingoftheapplication,LiquipelProtection LLCisnotidentifiedontheCoveredList(asaspecificallynamedentityoranyofitssubsidiariesor affiliates)asanentityproducing“covered”equipment. Sincerely, (Applicantsignature): (Applicantprintedname):Linguichu

Cover Letter(s)

LiquipelProtectionLLC Date:April2,2026 ProductModelNumber:827288 OJD-99,OJD-99D,PT827288 FCCID:2AVV6-827288 Towhomitmayconcern, Re:ProductCertificationRepresentativeAuthorizationLetter WeauthorizeQAILaboratoriesLtd.3980NorthFraserWay,BurnabyB.C. CanadaV5J5K5toactonourbehalfonallmattersconcerningtheabove namedequipment. Thisshallincludethefollowing: Testing Approvalapplicationsandprocedures WedeclarethatQAILaboratoriesLtd.isallowedtoforwardallinformation relatedtotheapprovalprojecttotheappliedcertificationbodyandtothe notificationentitiesandtodiscussanyissuesconcerningtheapproval application.AnyandallactscarriedoutbyQAILaboratoriesLtd.onour behalfshallhavethesameeffectasactsofourown. By: ContactListedonFCCWesbite Title:Manager Email:[email protected] Telephone:13802904065 Onbehalfof:LiquipelProtectionLLC

Cover Letter(s)

LiquipelProtectionLLC OfficeofEngineeringTechnology FederalCommunicationsCommission 7435OaklandMillsRoad Columbia,MD21046 USA Date:April2,2026 Subject;RequestforConfidentiality FCCID:2AVV6-827288 ToWhomItMayConcern, PursuanttotheprovisionsoftheCommission’srulesTitle47Sections§0.457and§0.459,we arerequestingtheCommissiontowithholdthefollowingattachment(s)asconfidential documentsfrompublicdisclosureindefinitely. Thesedocumentscontaindetailedsystemandequipmentdescriptionsandareconsideredas proprietaryinformationinoperationoftheequipment.Thepublicdisclosureofthese documentsmightbeharmfultoourcompanyandwouldgivecompetitorsanunfairadvantage inthemarket. SchematicDiagram BlockDiagram PartsList OperationalDescription Tune-upProcedure SoftwareSecurityRequirementsforUNIIdevices Inadditionaltoabovementioneddocuments,inordertocomplywiththemarketingregulations inTitle47CFR§2.803andtheimportationrulesinTitle47CFR§2.1204,whileensuringthat businesssensitiveinformationremainsconfidentialuntiltheactualmarketingofnewly authorizeddevices,werequestShortTermConfidentialityofthefollowingattachment(s); ExternalPhotos TestSetupPhotos InternalPhotos UserManual For45days,pursuanttoPublicNoticeDA04-1705. OR For180dayspursuanttoKDB726920D01. Itisourunderstandingthatallmeasurementtestreports,FCCIDlabelformatand correspondenceduringthecertificationreviewprocesscannotbegrantedasconfidential documentsandthisinformationwillbeavailableforpublicreviewoncethegrantofequipment authorizationisissued. Sincerely, Signature: Name:Linguichu Title:Manager

Cover Letter(s)

LiquipelProtectionLLC ModelDifference Date:Mar.30,2026 Productdescription:827288 OJD-99,OJD-99D,PT827288 FCCID:2AVV6-827288 827288istestedmodel,othermodelsarederivativemodels.Themodelsare identicalincircuit,onlydifferentonthemodelnames.Sothetestdataof827288can representtheremainingmodels. Client’ssignature: Client’sname/title:Linguichu/Manager Contactinformation/address:19800MacArthurBlvd.Suite300,Irvine

External Photos

FCCID:2AVV6-827288 EUTPHOTOS(ExternalPhotos) FCCID:2AVV6-827288 FCCID:2AVV6-827288 FCCID:2AVV6-827288 ※※※※※ENDOFREPORT※※※※※

ID Label/Location Info

Size:3mmX20mm FCCID:2AVV6-827288

Internal Photos

FCCID:2AVV6-827288 EUTPHOTOS(InternalPhotos) FCCID:2AVV6-827288 FCCID:2AVV6-827288 FCCID:2AVV6-827288 PhoneCoil FCCID:2AVV6-827288 AirPodsCoil FCCID:2AVV6-827288 iWatchCoil FCCID:2AVV6-827288 ※※※※※ENDOFREPORT※※※※※

RF Exposure Info

ProjectNo.:ZKT-260323L3060E-2 Page 1 of 9 FCCTESTREPORT FCCID:2AVV6-827288 ReportNumber...................................:ZKT-260323L3060E-2 DateofTest.....................................:Mar.5,2026-Mar.18,2026 Dateofissue ......................................... :Mar.18,2026 TestResult .......................................... : PASS TestingLaboratory. .......................... :ShenzhenZKTTechnologyCo.,Ltd. Address...............................................: 1/F,No.101,BuildingB,No.6,TangweiCommunityIndustrial Avenue,FuhaiStreet,Bao'anDistrict,Shenzhen,China Applicant'sname ............................. : LiquipelProtectionLLC Address ............................................... : 19800MacArthurBlvd.Suite300,Irvine Manufacturer'sname......................: HuizhouAojiadaTechnologyCo.,Ltd. Address ............................................... : Room1001,Unit29,No.6XinhuaAvenue,ChenjiangSubdistrict, Huizhou,Guangdong,China Testspecification: Standard ................................................ :KDB680106D01WirelessPowerTransferv04 Testprocedure ..................................... :/ Non-standardtestmethod................:N/A TestReportFormNo........................: TRF-EL-107_V0 TestReportForm(s)Originator.....: ZKTTesting MasterTRF........................................: Dated:2020-01-06 ThisdevicedescribedabovehasbeentestedbyZKT,andthetestresultsshowthattheequipmentunder test(EUT)isincompliancewiththeFCCrequirements.Anditisapplicableonlytothetestedsample identifiedinthereport. Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofZKT,thisdocumentmay bealteredorrevisedbyZKT,personalonly,andshallbenotedintherevisionofthedocument. Productname.....................................:3in1Wirelesschargerr Trademark...........................................: / Model/Typereference.........................: 827288 OJD-99,OJD-99D,PT827288 Ratings..................................................: Input:DC9V/3A Output:Phone:5W/7.5W/10W/15W AirPods:3W(max) iWatch:3W(max) ProjectNo.:ZKT-260323L3060E-2 Page 2 of 9 Testingprocedureandtestinglocation: TestingLaboratory ....................................... :ShenzhenZKTTechnologyCo.,Ltd. Address ............................................................ :1/F,No.101,BuildingB,No.6,TangweiCommunity IndustrialAvenue,FuhaiStreet,Bao'anDistrict, Shenzhen,China JimLiu Testedby(name+signature) ....................... : JacksonFang Reviewer(name+signature).......................: Approved(name+signature).......................: LakeXie ProjectNo.:ZKT-260323L3060E-2 Page 3 of 9 ProductName:3in1Wirelesscharger ProductModelNo.:827288 TestAuxiliary:AC/DCAdapter,Mobilephone,Earphone,Applewatch TestAuxiliaryModelNo.:191106C,ultra2,iPhone12,A2031 TransmittingmodeKeeptheEUTincontinuouslywirelesschargingmode Powersupply: Input:DC9V/3A Output:Phone:5W/7.5W/10W/15W AirPods:3W(max) iWatch:3W(max) TestDescription:PhoneBattery>98%,=50%and<1%aretested,andtheworstis<1%. TestModes:Description: PhoneCoil Mode1:98%PhoneLoad(110.1-205kHz) Mode2:50%PhoneLoad(110.1-205kHz) Mode3:1%PhoneLoad(110.1-205kHz) AirPodsCoil Mode4:98%AirPodsLoad(110.1-205kHz) Mode5:50%AirPodsLoad(110.1-205kHz) Mode6:1%AirPodsLoad(110.1-205kHz) iWatchCoil Mode7:98%iWatchLoad(300-360kHz) Mode8:50%iWatchLoad(300-360kHz) Mode9:1%iWatchLoad(300-360kHz) PhoneCoil+AirPodsCoil+iWatchCoil Mode10:1%iWatchLoad(300-360kHz)+AirPods Load(110.1-205kHz)+PhoneLoad(110.1-205kHz) Record Note:Allmodeshavebeentested,andthereportonlyreflectstheworstcasedata. ProjectNo.:ZKT-260323L3060E-2 Page 4 of 9 RFExposureEvaluation 1MeasuringStandard 1.1Accordingto§1.1307(b)(1),systemsoperatingundertheprovisionsofthissectionshallbeoperatedina mannerthatensuresthatthepublicisnotexposedtoradiofrequencyenergylevelinexcessofthe Commission’sguidelines.Accordingto§1.1310and§2.1091RFexposureiscalculated.According KDB680106D01:KDB680106D01WirelessPowerTransferv04. 1.2MEASUREMENTUNCERTAINTY Thereporteduncertaintyofmeasurementy±U,whereexpendeduncertaintyUisbasedona standarduncertaintymultipliedbyacoveragefactorofk=2,providingalevelofconfidenceof approximately95%. No.ItemUncertainly 1H-filed±0.93dB 2E-filed±0.51dB 2Requirements TheEUTdoescomplywithitem5(b)ofKDB680106V04 1)Thepowertransferfrequencyisbelow1MHz. Yes,thedeviceoperateinthefrequencyrangefrom115-205kHz,360±1.1kHz. 2)Theoutputpowerfromeachtransmittingelement(e.g.,coil)islessthanorequalto25watts. Yes,themaximumoutputpoweroftheprimarycoilis25W. 3)Aclientdeviceprovidingthemaximumpermittedloadisplacedinphysicalcontactwiththetransmitter(i.e., thesurfacesofthetransmitterandclientdeviceenclosuresneedtobeinphysicalcontact). Yes,thesurfacesofthetransmitterandclientdeviceenclosuresareinphysicalcontact. 4)Only§2.1091-Mobileexposureconditionsapply(i.e.,thisprovisiondoesnotcover§2.1093-Portable exposureconditions).. Yes,theEUTisaMobileWirelessCharger. 5)TheE-fieldandH-fieldstrengths,atandbeyond20cmsurroundingthedevicesurface,aredemonstrated tobelessthan50%oftheapplicableMPElimit,perKDB447498,Table1. Yes,theEUTfieldstrengthlevelsareless50%xMPElimit. 6)Forsystemswithmorethanoneradiatingstructure,theconditionsspecifiedin(5)mustbemetwhenthe systemisfullyloaded(i.e.,clientsabsorbingmaximumpoweravailable),andwithalltheradiatingstructures operatingatmaximumpoweratthesametime,asperdesignconditions. Yes,theEUThasonlyonecoil,alltestmodesmettheconditionsspecifiedin(5). Limits Thecriterialistedinthefollowingtableshallbeusedtoevaluatetheenvironmentimpactofhumanexposure toradiofrequency(RF)radiationasspecifiedin1.1307(b) LimitsforMaximumPermissibleExposure(MPE): ProjectNo.:ZKT-260323L3060E-2 Page 5 of 9 3TestSetup 4TestProcedure 1)TheRFexposuretestwasperformedon360degreeturntableinanechoicchamber. 2)Themeasurementprobewasplacedattestdistance(20cmandabovefromallsidesandTop)whichis betweentheedgeofthechargerandthegeometriccentreofprobe. 3)Theturntablewasrotated360ddegreetosearchofhigheststrength. 4)Thehighestemissionlevelwasrecordedandcomparedwithlimitassoonasmeasurementofeachpoin…

Text truncated - open the document above for the full version.

Test Report

Page1 of 4 承認書 SPECIFICATIONFORAPPROVAL 客戶: CUSTOMER: HuizhouAojiadaTechnologyCo.,Ltd. 客戶料號: CUSTP/N: 料號: FINEP/N: G42.5-6.5UHunicoil0.08*24P*2-10TS 産品型號: DESC: Φ42.5MMX5.0MMX0.8MMslotting 日期: DATE: 2024/11/12 版本: Version: A.0 擬制 PREPAREDBY 審核 CHECKEDBY 批准 APPROVEDBY 客戶承認 CUSTOMERAPPROVE 黄燕铭 Huang Yanming 宁元安 NingYuan'an 黄锦华 HuangJinhua 东莞市西联干城科技有限公司 DongguanXiLiangGanchengTechnologyCo.,Ltd. 工廠地址:东莞市东坑镇骏发路 123 号三甲高新技术产业园 2 栋 8 楼 FactoryAddress:Building2,8thFloor,SanjiaHigh-techIndustrialPark,JunfaRoad,DongkengTown,DongguanCity TEL:0769-82989159 FAX:0769-82989159 E-mail:[email protected] Page2 of 4 版本變更履歷 VersionChangeHistory 版本 Rev. 變更前 BeforeChange 變更後 AfterChange 更改日期 ChangeDate 批准 ApprovedBy A.0 newissue ----2024/11/12 Huang Yanming Page3 of 4 SPECIFICATION 産品型號: DESC Φ20.5x39-6.5uH-0.08x24PX2P-12mm 版本 Rev:A.0 客戶CUST: XXX 客户料号CUSTP/N: 一、尺寸DIMENSION:(mm) 二、原理图SCHEMATICDIAGRAM: A 42.0+0.5 B 39±1 C 12±2 D 3±2 E 1.6±0.2 F 0.8±0.1 G 20.5±0.5 注: 1.交叉出线; Crossingoutofthe competition; 2.出线位置缠8mm(ref)宽度高 温胶纸1-2Ts; Wraptheoutletpositionwith 8mm(ref)widthheat-resistant adhesivetapefor1-2turns. 3.线圈贴圆形硬磁片带槽,磁 片尺寸43.5±0.5mm,内孔 5.0mm,厚度为0.8±0.1mm。 Thecoilisfittedwithacircular hardmagneticsheetthathas slots.Thesizeofthemagnetic sheetis43.5±0.5mm,the innerholeis5.0mm,andthe thicknessis0.8±0.1mm. Page4 of 4 三、绕线参数WindingSpecification: 序号 NO. 端子 TERMINAL 线径 WIRE 圈数 Turns 绕线方向 WindingDirection 1SFHotairline0.08*24PX210TsCCW 四、电气特性ELECTRICALCHARACTERISTICS: 温度TEMPERATURE:25±10°C,湿度RELATIVEHUMIDITY:65±20% 序号 NO. 项目 ITEM 端子 TERMINAL 标准 SPECIFICATION 测试条件 TESTFREQUENCY 测试仪器 TESTEQUIPMENTS 1IND.S-F3.8uH±20%Singlecoil100KHz/1.0VLCZMETER1062B 2IND.S-F6.5uH+10%Addmagnetic chips 100KHz/1.0VLCZMETER1062B 3DCRS-F≤120mΩ100KHz/1.0VLCZMETER502B 4QS-F ≥39 100KHz/1.0VLCZMETER502B 擬制/日期PREPAREDBY/DATE審核/日期CHECKEDBY/DATE 黄燕铭HuangYanming2024/11/12黄锦华HuangJinhua2024/11/12

Test Report

产 品 规 格 书specification 02504 specification number 201002 2025/4/1 effective date 0 customer name Wireless charging product Huizhou Aojiada Technology Co., Ltd. typecoil TX-DZ53045010-K7.3-L110Slot for runway (runway type Top Intelligence Part Number ) Customer Material Number 【 □ 新版发行 , □ 版本修订】 【 本规范含目录共 3 页 】 【 RoHS Compliant Parts 】 authorized strengthaudit Li P ratify inghui / Ma Xiangping 广东顶智电子科技有限公司 Guangdong Dingzhi Electronic Technology Co., Ltd. 工厂地址:广东省惠州市龙门县迎宾大道1231号一楼 Factory Address: 1231 Xingbin Avenue, Lingmen County, Huizhou City, Guangdong Province, 1st Floor 电话phone:13147097490 日期 This acknowledgement form must be signed and returned by the customer within 30 days of receipt. Failure to do so within the specified period will be regarded as compliance with the standards stated in this form during the production process. : 【Customer approval】 Acknowledgment status: □make a clean breast of □Conditional approval □disallow ratifyauditrecheckexamine explain: √ 产 品 规 格 书specification customer name Huizhou Aojiada Technology Co., Ltd. Customer Material Number 0 T2025040100 Top Intelligence Part Number X-DZ53045010-K7.3-L110 Slot for runway (runway type) specification number 2 0 examine and Change content / effective Release/Revision History versionsdate reason approve 12025/4/10 Li PNew specification releaseinghui authorized strengthaudit ratify Li Pinghui / Ma Xiangping 产 品 规 格 书specification 0 202504010020 versions 1 (单位unit ♦、外形尺寸boundary dimension : mm) A28.5 ±1.0 B20.8 ±1.0 C49.2 ±1.0 D41.0 ±1.0 E110.0 ±2.0 F3.0 ±2.0 H2.5 ±0.5 I1.0 ±0.3Disk thickness J53.0 ±1.0 K45.0 ±1.0 (1)wire diamete remark r: 0.08*105P (2)Number of turns in the coil:9TS (3)Does the tail line cross over: Yes (4)The coil and the magnetic sheet need to be adhered in the center. (5)Coil package with 5mm high-temperature adhesive (6)Magnetic disk without adhesive backing ♦、electrical specification: parameterspecificationtest condition L test instrument 07.3±10%μH100KHz/1V■TH1816B Q>68 min100KHz/1V■TH1816B DCR<47mΩ@ 25 °C ■CH-502BC ♦、temperature grade: -40°C~ 125 operating temperature °C ♦、材料清单bill of materials: serial number Trade name material specification supplierremark 1 53*45*1.0*21*0.4 magnetic sheet TPC40Manganese zinc 2 0.08*105 copper wire Penameled wire 3 5M high- temperature tape M Environmental protection tape 4 107tinH Qiandao Environmental Protection Tin 5 glueYellow glueeco-friendly adhesive authorized strength auditratify Li Pinghui / Ma Xiangping customer name Huizhou Aojiada Technology Co., Ltd. Customer Material Number Top Intelligence Part Number X-DZ53045010-K7.3-L110 Slot for runway (runway type) specification number

Test Report

深圳市深广电子科技有限公司 ShenzhenShenguangElectronicTechnologyCo.,LTD Address:Factory401,1165GuangjingRoad,GuihuazhuangCommunity, GuanlanStreet,LonghuaDistrict,ShenzhenCity 客户 /Client HuizhouAojiadaTechnologyCo.,Ltd. 名称 /TYPEG25X2.3X8.1UH 产品型号 ModelNO 产品编号 Partnunbering 客户料号 Clientp/NO 工程编号 EnginrerNOTQE1800510003 日期/Date2023-11-3 编制/Prepared审核/Checked认可/Approved XieYanQiDuanJiaWangXieXiaoZai 客户认可回签/AuthorixedSignaturureCompanyChop 本公司工程部/ForEnginerDepartnerOnly 修改内容/RrvisedContent认可日期/APProvedDate 深圳市深广电子科技有限公司 ShenzhenShenguangElectronicTechnologyCo.,LTD Address:Factory401,1165GuangjingRoad,GuihuazhuangCommunity, GuanlanStreet,LonghuaDistrict,ShenzhenCity 工程/Enginrer认可/QCAPProved认可日期/APProved 一、线圈工艺/WindingProcese: NOwindingguage numberof windings directionof winding remark 1N12UEW-B-0.08*24p13TSCCW 2 二.电气性能/FEATURES: 1.测试条件(Testconditions):25°C,65%RH@100KHz/1V 1.1电感量(Inductance) 1.11L0A(Singlecoil)=3.8uH±20% 1.12L0A(Coil+magneticdisc)=8.1uH±10% 1.2Q=20MIN 1.3直流电阻(DCR):145mΩMAX 1.4工作温度(OperatingTemperature):-25°C~85°C 2.Testinstrument:L:CH1068+1310;DCR:502BC;SIZE:Callipers 3.MaterialList NOprojectmaterials 1WIRE¢ 0.08*24p2UEW 深圳市深广电子科技有限公司 ShenzhenShenguangElectronicTechnologyCo.,LTD Address:Factory401,1165GuangjingRoad,GuihuazhuangCommunity, GuanlanStreet,LonghuaDistrict,ShenzhenCity 三.电路图/CIRCUITDIAGRAM Unit : MM 四.外形图/OUTSIDEDIAGRA 2FERRITE G25softmagnetism 3GLUE WhiteGlueBY882 4SOLDERXCD-907B 5Adhesivedouble-sidedadhesive 6Magnetism 7.5*2.5(greaterthanthestrengthof 3000GS) 7 ABCDEFHIJK STD 24±0.52.7±0.2 23.7±0.4 20.5min 13.5±0.3 2.3±0.25 7.5±0.3 1±1 12±2 7.5x2.5 深圳市深广电子科技有限公司 ShenzhenShenguangElectronicTechnologyCo.,LTD Address:Factory401,1165GuangjingRoad,GuihuazhuangCommunity, GuanlanStreet,LonghuaDistrict,ShenzhenCity Unit : MM 五.包装 /PACKAGE 5.1包装图片/PackingPicture: 5.2包装数量PackingQuantity Item 数量Quantity规格Material 盒Box 256PCS345*240*30MM 箱子BigCarton 768PCS360*250*140MM 深圳市深广电子科技有限公司 ShenzhenShenguangElectronicTechnologyCo.,LTD Address:Factory401,1165GuangjingRoad,GuihuazhuangCommunity, GuanlanStreet,LonghuaDistrict,ShenzhenCity 5.3包装以现有包装盘为参照标准,以实际出货包装为准,如有特需要求可以定制。 Thepackagingshallbebasedontheexustingpackingplateandtheactualdeliverypackageshall prevail.Ifthereisanyrequirement,wecancustomizeit. 深圳市深广电子科技有限公司 ShenzhenShenguangElectronicTechnologyCo.,LTD Address:Factory401,1165GuangjingRoad,GuihuazhuangCommunity, GuanlanStreet,LonghuaDistrict,ShenzhenCity 六、贮存和使用条件StorageandUsecondition 6.1贮存条件Storagecondition 6.1.1建议贮存条件:温度-25°C~85°C,湿度70%(Max.) Recommendedkeepingconditions:-25°C~85°C,70%RH(Max.) 6.1.2贮存期限:自生产之日起六个月内 Storagelife:Withinthelimitsofsixmonthsfrombeingproduced. 6.2使用条件Usecondition 使用条件限制:温度=-25°C ~ 85°C,湿度≤90% Useconditionlimit:T=-25°C~85°C,RH≤90%.

Test Report

ProjectNo.:ZKT-260323L3060E-1 Page 1 of 24 FCCTESTREPORT FCCID:2AVV6-827288 ReportNumber...................................:ZKT-260323L3060E-1 DateofTest......................................: Mar.5,2026-Mar.18,2026 Dateofissue.........................................: Mar.18,2026 TestResult..........................................: PASS TestingLaboratory............................: ShenzhenZKTTechnologyCo.,Ltd. Address ............................................... : 1/F,No.101,BuildingB,No.6,TangweiCommunityIndustrial Avenue,FuhaiStreet,Bao'anDistrict,Shenzhen,China Applicant'sname.............................:LiquipelProtectionLLC Address...............................................:19800MacArthurBlvd.Suite300,Irvine Manufacturer'sname ...................... :HuizhouAojiadaTechnologyCo.,Ltd. Address...............................................: Room1001,Unit29,No.6XinhuaAvenue,ChenjiangSubdistrict, Huizhou,Guangdong,China Testspecification: Standard ................................................ :FCCCFRTitle47Part15SubpartC Testprocedure.....................................:ANSIC63.10-2020 Non-standardtestmethod................:N/A TestReportFormNo........................: TRF-EL-107_V0 TestReportForm(s)Originator ..... : ZKTTesting MasterTRF ........................................ : Dated:2020-01-06 ThisdevicedescribedabovehasbeentestedbyZKT,andthetestresultsshowthattheequipmentunder test(EUT)isincompliancewiththeFCCrequirements.Anditisapplicableonlytothetestedsample identifiedinthereport. Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofZKT,thisdocumentmay bealteredorrevisedbyZKT,personalonly,andshallbenotedintherevisionofthedocument. Productname.....................................:3in1Wirelesscharger Trademark...........................................:/ Model/Typereference ......................... : 827288 OJD-99,OJD-99D,PT827288 Ratings .................................................. : Input:DC9V/3A Output:Phone:5W/7.5W/10W/15W AirPods:3W(max) iWatch:3W(max) ProjectNo.:ZKT-260323L3060E-1 Page 2 of 24 Testingprocedureandtestinglocation: TestingLaboratory.......................................:ShenzhenZKTTechnologyCo.,Ltd. Address ............................................................ :1/F,No.101,BuildingB,No.6,TangweiCommunity IndustrialAvenue,FuhaiStreet,Bao'anDistrict, Shenzhen,China JimLiu Testedby(name+signature) ....................... : JacksonFang Reviewer(name+signature).......................: LakeXie Approved(name+signature) ....................... : ProjectNo.:ZKT-260323L3060E-1 Page 3 of 24 TABLEOFCONTENTS 1.VERSION.................................................................................................................................................................4 2.TESTSUMMARY...................................................................................................................................................5 2.1TESTFACILITY...............................................................................................................................................6 2.2MEASUREMENTUNCERTAINTY................................................................................................................6 3.GENERALINFORMATION..................................................................................................................................7 3.1GENERALDESCRIPTIONOFEUT.............................................................................................................7 3.2Testmode.........................................................................................................................................................7 3.3BlockDiagramofEUTConfiguration............................................................................................................8 3.4TestConditions.................................................................................................................................................8 3.5DescriptionOfSupportUnits(ConductedMode).......................................................................................8 3.6EQUIPMENTSLISTFORALLTESTITEMS..............................................................................................9 4.CONDUCTEDEMISSIONTEST........................................................................................................................11 4.1CONDUCTEDEMISSIONMEASUREMENT............................................................................................11 4.1.1POWERLINECONDUCTEDEMISSIONLimits...................................................................................11 4.1.2TESTPROCEDURE..................................................................................................................................11 4.1.3DEVIATIONFROMTESTSTANDARD..................................................................................................11 4.1.4TESTSETUP..............................................................................................................................................12 4.1.5EUTOPERATINGCONDITIONS............................................................................................................12 4.1.6TestResult...................................................................................................................................................13 5.RADIATEDEMISSIONMEASUREMENT........................................................................................................15 5.1RadiatedEmissionLimits.............................................................................................................................15 5.2AnechoicChamberTestSetupDiagram....................................................................................................16 5.3TestProcedure...............................................................................................................................................16 5.4DE…

Text truncated - open the document above for the full version.

Test Setup Photos

FCCID:2AVV6-827288 EUTTESTPHOTOS FCCID:2AVV6-827288 ※※※※※ENDOFREPORT※※※※※

Contact Information

Applicant

Lin guichu(manager)
[email protected]Fax: 86-23116366

Technical Contact

Liquipel Protection LLCLin guichu
[email protected]

19800 MacArthur Blvd. Suite 300, Irvine · United States

Test Firm

Shenzhen ZKT Technology Co., Ltd.Lake Xie
[email protected]

Technical Specifications

#Rule PartsFrequency RangePower Output
115C0.1101 MHz - 0.205 MHz-
215C0.3 MHz - 0.36 MHz-
Confidentiality
Long Term

Other Applications from Liquipel Protection LLC

3 in 1 Wireless charger - FCC ID 2AVV6-827371 - Liquipel Protection LLC
2AVV6-827371

3 in 1 Wireless charger

Aug 14, 2026

Equipment Class

DCD - Part 15 Low Power Transmitter Below 1705 kHz
3 in 1 Wireless charger - FCC ID 2AVV6-827372 - Liquipel Protection LLC
2AVV6-827372

3 in 1 Wireless charger

Aug 14, 2026

Equipment Class

DCD - Part 15 Low Power Transmitter Below 1705 kHz
Powertek 3in1 Charge Station - FCC ID 2AVV6-827373 - Liquipel Protection LLC
2AVV6-827373

Powertek 3in1 Charge Station

Jul 08, 2026

Equipment Class

DCD - Part 15 Low Power Transmitter Below 1705 kHz
Magnetic Car Vent Charger - FCC ID 2AVV6-802961 - Liquipel Protection LLC
2AVV6-802961

Magnetic Car Vent Charger

Jul 17, 2023

Equipment Class

DCD - Part 15 Low Power Transmitter Below 1705 kHz
3 in 1 Wireless Charge Stand - FCC ID 2AVV6-802962 - Liquipel Protection LLC
2AVV6-802962

3 in 1 Wireless Charge Stand

Jul 17, 2023

Equipment Class

DCD - Part 15 Low Power Transmitter Below 1705 kHz