Meter Inc.

Application Details

Equipment Class
6ID - 15E 6 GHz Low Power Indoor Access Point
Date of Grant
May 05, 2026
Application Purpose
Original Equipment
Equipment Note
Wi-Fi 7 Wall Plate Access Point
Frequency Range
5955.00000000 - 7115.00000000
Company
Meter Inc.
Country
United States

Documents & Files

Select a file to view

Attestation Statements

↗
↗
↗

Cover Letter(s)

↗
↗
↗
↗
↗

ID Label/Location Info

↗

RF Exposure Info

↗

Test Report

↗
↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Attestation Statements

Meter Inc. 548 Market St, PMB 22716 San Francisco, CA 94104 United States January 18, 2026 To: Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 RE FCC ID 2AVVVA2 Declaration of 6 GHz Operation To Whom It May Concern: We, Meter Inc., attest that this device under FCC ID 2AVVVA2 complies with device protocol requirements and operational restrictions as a low-power indoor access point 6ID. Attestation of device protocols We attest that this access pointʼs Transmit Power Envelope TPE mechanism contains information elements for power limits when connecting client and/or subordinate devices. The TPE information is found in 802.11 protocol packets that can be read by associated devices. Those packets AP beacons and probe responses) display a regulatory flag that details the 6 GHz device class. 802.11 clients and subordinate devices may view this field, even before associating with the AP. Device restriction acknowledgement We acknowledge that: A. This access point, while operating in the 5.9257.125 GHz band, is supplied power from a wired connection, has an integrated antenna, is not battery-powered, and does not have a weatherized enclosure. B. This device's operation will not be used on oil platforms, cars, trains, boats, and aircraft, except that operation of this device is permitted in large aircraft while flying above 10,000 feet only in the 5.9256.425 GHz band. C. This device will not be used for the control of or communications with unmanned aircraft systems, including drones. If you have any questions about this declaration, please feel free to contact me. Regards, Saied Haddad Regulatory Compliance Meter Inc. 510 2968995 [email protected] 1

Attestation Statements

Meter Inc. 548 Market St, PMB 22716 San Francisco, CA 94104 United States January 18, 2026 To: Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 FCC ID 2AVVV2 In reference to: Covered listed Attestation Part 2.911(d)(7) Filing Grantee Code: 2AVVV FRN 0029316551 Designation of Agent for Service of Process To Whom It May Concern: Meter Inc. (“the applicantˮ) certifies that, as of the date of the filing of the application, we designate ourselves as the U.S. agent for service of process. The applicant as required by section 2.911(d)(7), will also serve as the agent for service of process for the above referenced FCC Grantee Code. The service of process includes, but is not limited to, delivery of any correspondence, notices, orders, decisions, and requirements of administrative, legal, or judicial process related to Commission proceedings. The applicant acknowledges that they will maintain an agent for service of process in the United States for no less than one year after either the grantee has permanently terminated all marketing and importation of the applicable equipment within the U.S., or the conclusion of any Commission-related administrative or judicial proceeding involving the equipment, whichever is later. The applicant further acknowledges their responsibility to inform the FCC whenever the following agent information changes. Designated U.S. Agent Information: FRN 0029316551 Company Name: Meter Inc. Address: 548 Market St, PMB 22716 San Francisco, California 94104 United States Contact Person: Saied Haddad Telephone: 510 2968995 Email: [email protected] 1 Regards, Saied Haddad Regulatory Compliance Meter Inc. 510 2968995 [email protected] 2

Attestation Statements

Meter Inc. 548 Market St, PMB 22716 San Francisco, CA 94104 United States April 3, 2026 Attestation Statements for the Covered List To: Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 Regarding FCC ID 2AVVVA2 Section 2.911(d)(5)(i) Statements Meter Inc. (“the applicantˮ) certifies that the equipment for which authorization is sought is not “coveredˮ equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. Meter Inc. (“the applicantˮ) certifies that the equipment for which authorization is sought does not include cybersecurity or anti-virus software produced or provided by Kaspersky Lab, Inc. or any of its successors and assignees, including equipment with integrated Kaspersky Lab, Inc. (or any of its successors and assignees) cybersecurity or anti-virus software pursuant to DA24886 and KDB 986446 D01 Covered Equipment Guidance section B2a. Meter Inc. (“the applicantˮ) certifies that the equipment for which authorization is sought is not a consumer-grade router and does not have any routing capability or features and therefore is not covered equipment pursuant to DA 26278. The device in this application is inherently compliant based on hardware limitations and software controls, wherein Meter Inc. actively selects the hardware and software components to exclude anything from an entity on the covered list. The Meter OS prevents any software from being modified or added by third parties or non-Meter Inc. entities. Section 2.911(d)(5)(ii) Statement Meter Inc. (“the applicantˮ) certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List (as a specifically named entity or any of its subsidiaries or affiliates) as an entity producing “coveredˮ equipment. Regards, Saied Haddad Regulatory Compliance Meter Inc. 510 2968995 Email: [email protected] 2

Cover Letter(s)

Meter Inc. 548 Market St, PMB 22716 San Francisco, CA 94104 United States January 18, 2026 To: Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 FCC ID 2AVVVA2 Request for Confidentiality To Whom It May Concern: Permanent Confidentiality We, Meter Inc., hereby request to withhold permanently from public review certain portions of the application for equipment certification for the referenced FCC identifiers. This request for confidentiality is made pursuant to 47 CFR 0.457(d) and 0.459 of the FCC Rules. In particular, the following sections of the application are to be kept permanently confidential: ● Schematics ● Block diagrams ● Theory of Operation ● Software-security file Short-term Confidentiality Request is hereby submitted by Meter Inc. to withhold from public review for a period of 180 days from the date of the Grant of Equipment Authorization and prior to marketing, certain portions of the application for equipment certification for the referenced FCC identifiers. This request for confidentiality is made pursuant to 47 CFR 0.457(d) and 0.459 of the FCC Rules. In particular, the following sections of the application are to be kept confidential for the maximum period of 180 days) from the date of Authorization: ● Test setup photos ● External photos ● Internal photos ● User manual Rationale for request for confidentiality: 1 Meter Inc. has invested considerable time and materials in research and development to produce the referenced product. Permanent confidentiality: Disclosure of the permanently confidential portions of this application to competitors would not only give them significant competitive advantages in developing similar products, but would also disclose successful implementation of unpublished, leading edge technology developed by us. Short term confidentiality: Disclosure of the short-term confidential portions of this application during the period of importation and/or distribution would reveal key aspects of proprietary technology to competitors and diminish the value of our investment in research and development. If you have any questions about this request, please feel free to contact me. Regards, Saied Haddad Regulatory Compliance Meter Inc. 510 2968995 Email: [email protected] 2

Cover Letter(s)

Meter Inc. 548 Market St, PMB 22716 San Francisco, CA 94104 United States January 18, 2026 To: Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 RE FCC ID 2AVVVA2 Declaration of Radiated Test Measurement To Whom It May Concern: We, Meter Inc., declare the 6 GHz testing was performed using the radiated method, therefore the antenna gain has not been accounted for and no additional antenna gain information is required for those measurements. If you have any questions about this declaration, please feel free to contact me. Regards, Saied Haddad Regulatory Compliance Meter Inc. 510 2968995 Email: [email protected] 1

Cover Letter(s)

Meter Inc. 548 Market St, PMB 22716 San Francisco, CA 94104 United States January 18, 2026 To: Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 RE FCC ID 2AVVVA2 Declaration of Professional Installation To Whom It May Concern: We, Meter Inc., declare that this device will be deployed through controlled distribution channels. Output power settings are provided to professional installers to ensure regulatory compliance, offering only power reduction capabilities. This device is not intended for sale to the general public. Professional training and support are provided by Meter Inc. as a part of an authorized installer program. If you have any questions about this declaration, please feel free to contact me. Regards, Saied Haddad Regulatory Compliance Meter Inc. 510 2968995 [email protected]

Cover Letter(s)

Meter Inc. 548 Market St, PMB 22716 San Francisco, CA 94104 United States January 18, 2026 To: Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 RE FCC ID 2AVVVA2 Agent Authorization To Whom It May Concern: We, Meter Inc., hereby authorize the following person to act as our agent in the preparation of an application for equipment authorization to the FCC Rules and Regulations. Sporton International Inc. Address : No.52, Huaya 1st Rd., Guishan Dist., Taoyuan City 333, Taiwan R.O.C. Name : Leo Huang Job Title : VP e-mail : [email protected] We further certify that neither the applicant nor any party to this application, as defined in 47 CFR Ch. 1.2002(b), is subject to a denial to Federal benefits, that include FCC benefits, pursuant to section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. § 862. This appointment also includes the authority to complete FCC Form 731 on our behalf and sign the application as an authorized agent. If you have any questions about this authorization, please feel free to contact me. Regards, Saied Haddad Regulatory Compliance Meter Inc. 510 2968995 [email protected] 1

Cover Letter(s)

Meter Inc. 548 Market St, PMB 22716 San Francisco, CA 94104 United States April 3, 2026 To: Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 RE FCC ID 2AVVVA2 Attestation of Enterprise Access Point Compliance for DA 26278 To Whom It May Concern: We, Meter Inc., hereby certify that the equipment in this application (FCC ID 2AVVVA2, Model:A2)is not a consumer-grade router and is not available to end users outside a controlled distribution channel and professional installation and therefore is not covered equipment pursuant to DA 26278 and section 2.911(d)(5)(i) of the FCC rules. Please refer to the following details on the function of A2 access point to support this attestations: Enterprise Features and Design The A2 is an enterprise-grade access point, not intended for residential use and may not be installed by the customer. The A2 access point is deployed using professional installation in commercial locations. Furthermore, the following features are used in the access point that are only meant for non-consumer, enterprise use: ● Wireless Intrusion Detection System WIDS ● Radio profiles ● Automatic RF management ACS ● Packet captures ● WPA2Enterprise, WPA3Enterprise ● 802.11r, 802.11k, 802.11v, 802.11w ● VLANs ● Detailed event and audit logs ● Real-time event alerting ● Automatic and schedulable firmware upgrades ● Roaming and RADIUS authentication ● Guest networks and splash pages ● Controlled installation methods: proprietary professional mounting and PoE-powered only ● Meterʼs Network-As-AService business model and support/service contracts Professional Installation and Controlled Distribution The A2 device will be deployed through controlled distribution channels. Installation instructions and restrictions as well as output power settings are provided to professional installers to ensure regulatory compliance, offering only power reduction capabilities. This device is not intended for sale to the general public and is not available outside the Meter enterprise sales channel. Users may 1 not acquire or handle this device without a Meter Network service agreement and installation by an authorized installer and arranged by Meter Inc. Professional training and support are provided by Meter Inc. as a part of an authorized installer program. If you have any questions about this attestation, please feel free to contact me. Regards, Saied Haddad Regulatory Compliance Meter Inc. 510 2968995 [email protected] 2

ID Label/Location Info

Meter A2 Access Point Label and Location Back of the device

RF Exposure Info

Radio Exposure Evaluation Report Report No. : FA5N2105 TEL : 886-3-327-3456 Page Number : 1 of 14 FAX : 886-3-327-0973 Issued Date : Apr. 09, 2026 Report Template No.: HE1-A1 Ver5.0 Report Version : 01 FCC ID: 2AVVV-A2 Radio Exposure Evaluation Report FCC ID : 2AVVV-A2 Equipment : Wi-Fi 7 Wall Plate Access Point Brand Name : meter Model Name : A2 Applicant : Meter, Inc. 548 Market St, PMB 22716 San Francisco CA 94104 USA Manufacturer : Meter Inc. 548 Market St, PMB 22716 San Francisco CA 94104 USA Standard : 47 CFR FCC Part 2 Subpart J, section 2.1091 The product was received on Nov. 27, 2025, and testing was started from Jan. 29, 2026 and completed on Mar. 28, 2026. We, SPORTON INTERNATIONAL INC. Hsinhua Laboratory, would like to declare that the tested sample has been evaluated in accordance with the procedures given in 47 CFR FCC Part 2 Subpart J, section 2.1091 and shown compliance with the applicable technical standards. The test results in this report apply exclusively to the tested model / sample. Without written approval of SPORTON INTERNATIONAL INC. Hsinhua Laboratory, the test report shall not be reproduced except in full. ___________________________________________ Approved by: Jackson Tsai __________________________________________ SDoC by: XXXXX SPORTON INTERNATIONAL INC. Hsinhua Laboratory No.52, Huaya 1st Rd., Guishan Dist., Taoyuan City 333411, Taiwan (R.O.C.) Radio Exposure Evaluation Report Report No. : FA5N2105 TEL : 886-3-327-3456 Page Number : 2 of 14 FAX : 886-3-327-0973 Issued Date : Apr. 09, 2026 Report Template No.: HE1-A1 Ver5.0 Report Version : 01 FCC ID: 2AVVV-A2 Table of Contents HISTORY OF THIS TEST REPORT .................................................................................................................. 3 SUMMARY OF TEST RESULT ......................................................................................................................... 4 1 GENERAL DESCRIPTION .................................................................................................................... 5 1.1 Information .............................................................................................................................................. 5 1.2 Applicable Standards ............................................................................................................................. 8 1.3 Testing Location ..................................................................................................................................... 8 2 MAXIMUM PERMISSIBLE EXPOSURE ............................................................................................... 9 2.1 Limit of Maximum Permissible Exposure ............................................................................................... 9 2.2 RF Exposure Exempt Measurement .................................................................................................... 10 2.3 Multiple RF Sources Exposure ............................................................................................................. 11 2.4 MPE Calculation Method ...................................................................................................................... 12 2.5 Calculated Result and Limit .................................................................................................................. 13 Photographs of EUT V01 Radio Exposure Evaluation Report Report No. : FA5N2105 TEL : 886-3-327-3456 Page Number : 3 of 14 FAX : 886-3-327-0973 Issued Date : Apr. 09, 2026 Report Template No.: HE1-A1 Ver5.0 Report Version : 01 FCC ID: 2AVVV-A2 History of this test report Report No. Version Description Issued Date FA5N2105 01 Initial issue of report Apr. 09, 2026 Radio Exposure Evaluation Report Report No. : FA5N2105 TEL : 886-3-327-3456 Page Number : 4 of 14 FAX : 886-3-327-0973 Issued Date : Apr. 09, 2026 Report Template No.: HE1-A1 Ver5.0 Report Version : 01 FCC ID: 2AVVV-A2 Summary of Test Result Report Clause Ref Std. Clause Test Items Result (PASS/FAIL) Remark 2 - Exposure evaluation PASS - Declaration of Conformity: The test results with all measurement uncertainty excluded are presented in accordance with the regulation limits or requirements declared by manufacturers. Comments and Explanations: None Reviewed by: Ben Tseng Report Producer: Debby Hung Radio Exposure Evaluation Report Report No. : FA5N2105 TEL : 886-3-327-3456 Page Number : 5 of 14 FAX : 886-3-327-0973 Issued Date : Apr. 09, 2026 Report Template No.: HE1-A1 Ver5.0 Report Version : 01 FCC ID: 2AVVV-A2 1 General Description 1.1 Information 1.1.1 EUT General Information RF General Information Evaluation Mode Frequency Range (MHz) Operating Frequency (MHz) Modulation Type 2.4GHz WLAN 2400-2483.5 2412-2462 802.11b: DSSS (DBPSK, DQPSK, CCK) 802.11g/n: OFDM (BPSK, QPSK, 16QAM, 64QAM) VHT: OFDM (BPSK, QPSK, 16QAM, 64QAM, 256QAM) 802.11ax: OFDMA (BPSK, QPSK, 16QAM, 64QAM, 256QAM, 1024QAM) 802.11be: OFDMA (BPSK, QPSK, 16QAM, 64QAM, 256QAM, 1024QAM, 4096QAM) 5GHz WLAN 5150-5250 5250-5350 5470-5725 5725-5850 5180-5240 5260-5320 5500-5700 5745-5825 802.11a/n: OFDM (BPSK, QPSK, 16QAM, 64QAM) 802.11ac: OFDM (BPSK, QPSK, 16QAM, 64QAM, 256QAM) 802.11ax: OFDMA (BPSK, QPSK, 16QAM, 64QAM, 256QAM, 1024QAM) 802.11be: OFDMA (BPSK, QPSK, 16QAM, 64QAM, 256QAM, 1024QAM, 4096QAM) 6GHz WLAN 5925-7125 5955-7115 802.11ax: OFDMA (BPSK, QPSK, 16QAM, 64QAM, 256QAM, 1024QAM) 802.11be: OFDMA (BPSK, QPSK, 16QAM, 64QAM, 256QAM, 1024QAM,4096QAM) Bluetooth 2400-2483.5 2402-2480 LE: DSSS (GFSK) Radio Exposure Evaluation Report Report No. : FA5N2105 TEL : 886-3-327-3456 Page Number : 6 of 14 FAX : 886-3-327-0973 Issued Date : Apr. 09, 2026 Report Template No.: HE1-A1 Ver5.0 Report Version : 01 FCC ID: 2AVVV-A2 1.1.2 Antenna Information Ant. Brand Name Model Name Antenna Type Connector Support Radio 1 GrandTek 2G-1 PCB I-Pex 2.4G Radio 1 2 GrandTek 2G-2 PCB I-Pex 2.4G Radio 1 3 GrandTek 5G-1 PCB I-Pex 5G Radio 2 4 GrandTek 5G-2 PCB …

Text truncated - open the document above for the full version.

Test Report

RSE TX above 1GHz_Non-Beamforming Appendix F.2 Sporton International Inc. Page No. : F1 of F30 Summary Mode Result Type Freq Level Limit Margin Dist Condition Azimuth Height (Hz) (dBuV/m) (dBuV/m) (dB) (m) (°) (m) 5.925-6.425GHz - - - - - - - - - - 802.11a_Nss1,(6Mbps)_2TX Pass AV 12.38022G 38.57 54.00 -15.43 3 Vertical 65 1.16 802.11be EHT20_Nss1,(MCS0)_2TX Pass AV 12.39876G 40.32 54.00 -13.68 3 Horizontal 68 1.98 802.11be EHT40_Nss1,(MCS0)_2TX Pass AV 11.94269G 39.08 54.00 -14.92 3 Horizontal 6 1.81 802.11be EHT80_Nss1,(MCS0)_2TX Pass AV 11.97513G 38.81 54.00 -15.19 3 Horizontal 321 1.50 802.11be EHT160_Nss1,(MCS0)_2TX Pass AV 12.69014G 39.47 54.00 -14.53 3 Vertical 41 1.55 6.425-6.525GHz - - - - - - - - - - 802.11a_Nss1,(6Mbps)_2TX Pass AV 12.86734G 39.58 68.20 -28.62 3 Vertical 339 1.50 802.11be EHT20_Nss1,(MCS0)_2TX Pass AV 12.95256G 40.19 68.20 -28.01 3 Vertical 12 2.13 802.11be EHT40_Nss1,(MCS0)_2TX Pass AV 12.97063G 39.88 68.20 -28.32 3 Vertical 189 1.50 802.11be EHT80_Nss1,(MCS0)_2TX Pass AV 12.93294G 39.73 68.20 -28.47 3 Vertical 21 1.50 802.11be EHT160_Nss1,(MCS0)_2TX Pass AV 12.93176G 39.55 68.20 -28.65 3 Vertical 43 2.52 6.525-6.875GHz - - - - - - - - - - 802.11a_Nss1,(6Mbps)_2TX Pass AV 13.3953G 39.95 54.00 -14.05 3 Horizontal 9 2.51 802.11be EHT20_Nss1,(MCS0)_2TX Pass AV 13.38914G 40.45 54.00 -13.55 3 Horizontal 151 1.17 802.11be EHT40_Nss1,(MCS0)_2TX Pass AV 13.36172G 39.94 54.00 -14.06 3 Horizontal 315 1.46 802.11be EHT80_Nss1,(MCS0)_2TX Pass AV 13.25006G 39.95 54.00 -14.05 3 Horizontal 19 1.50 802.11be EHT160_Nss1,(MCS0)_2TX Pass AV 13.2964G 40.01 54.00 -13.99 3 Horizontal 193 1.31 6.875-7.125GHz - - - - - - - - - - 802.11a_Nss1,(6Mbps)_2TX Pass AV 7.125G 66.58 68.20 -1.62 3 Vertical 23 1.82 802.11be EHT20_Nss1,(MCS0)_2TX Pass AV 7.1255G 63.53 68.20 -4.67 3 Vertical 21 1.87 802.11be EHT40_Nss1,(MCS0)_2TX Pass AV 7.2323G 46.21 68.20 -21.99 3 Vertical 23 1.79 802.11be EHT80_Nss1,(MCS0)_2TX Pass AV 7.1261G 46.02 68.20 -22.18 3 Vertical 22 1.73 802.11be EHT160_Nss1,(MCS0)_2TX Pass AV 7.125G 49.17 68.20 -19.03 3 Vertical 24 1.57 Report No. : FR5N2105AE RSE TX above 1GHz_Non-Beamforming Appendix F.2 Sporton International Inc. Page No. : F2 of F30 Result Mode Result Type Freq Level Limit Margin Dist Condition Azimuth Height (Hz) (dBuV/m) (dBuV/m) (dB) (m) (°) (m) 802.11a_Nss1,(6Mbps)_2TX - - - - - - - - - - 5955MHz Pass AV 5.925G 43.01 68.20 -25.19 3 Vertical 343 1.08 5955MHz Pass AV 5.9544G 96.51 Inf -Inf 3 Vertical 343 1.08 5955MHz Pass PK 5.9025G 56.61 88.20 -31.59 3 Vertical 343 1.08 5955MHz Pass PK 5.9544G 106.87 Inf -Inf 3 Vertical 343 1.08 5955MHz Pass AV 11.91566G 38.46 54.00 -15.54 3 Vertical 323 3.00 5955MHz Pass PK 11.90444G 53.11 74.00 -20.89 3 Vertical 323 3.00 5955MHz Pass AV 11.91186G 38.51 54.00 -15.49 3 Horizontal 106 1.50 5955MHz Pass PK 11.89626G 52.83 74.00 -21.17 3 Horizontal 106 1.50 6195MHz Pass AV 12.38022G 38.57 54.00 -15.43 3 Vertical 65 1.16 6195MHz Pass PK 12.39872G 52.17 74.00 -21.83 3 Vertical 65 1.16 6195MHz Pass AV 12.38036G 38.56 54.00 -15.44 3 Horizontal 49 2.01 6195MHz Pass PK 12.38234G 53.00 74.00 -21.00 3 Horizontal 49 2.01 6415MHz Pass AV 12.83762G 39.51 68.20 -28.69 3 Vertical 201 1.50 6415MHz Pass PK 12.83292G 53.69 88.20 -34.51 3 Vertical 201 1.50 6415MHz Pass AV 12.83968G 39.50 68.20 -28.70 3 Horizontal 44 1.24 6415MHz Pass PK 12.82688G 53.44 88.20 -34.76 3 Horizontal 44 1.24 6435MHz Pass AV 12.86734G 39.58 68.20 -28.62 3 Vertical 339 1.50 6435MHz Pass PK 12.86658G 53.44 88.20 -34.76 3 Vertical 339 1.50 6435MHz Pass AV 12.8652G 39.57 68.20 -28.63 3 Horizontal 162 1.43 6435MHz Pass PK 12.86944G 53.73 88.20 -34.47 3 Horizontal 162 1.43 6475MHz Pass AV 12.95006G 39.56 68.20 -28.64 3 Vertical 46 1.13 6475MHz Pass PK 12.95752G 55.12 88.20 -33.08 3 Vertical 46 1.13 6475MHz Pass AV 12.95198G 39.47 68.20 -28.73 3 Horizontal 126 1.50 6475MHz Pass PK 12.9432G 54.28 88.20 -33.92 3 Horizontal 126 1.50 6515MHz Pass AV 13.03004G 39.51 68.20 -28.69 3 Vertical 42 1.50 6515MHz Pass PK 13.026G 54.18 88.20 -34.02 3 Vertical 42 1.50 6515MHz Pass AV 13.02284G 39.38 68.20 -28.82 3 Horizontal 356 2.43 6515MHz Pass PK 13.02108G 54.02 88.20 -34.18 3 Horizontal 356 2.43 6535MHz Pass AV 13.07728G 39.33 68.20 -28.87 3 Vertical 221 1.50 6535MHz Pass PK 13.07174G 53.68 88.20 -34.52 3 Vertical 221 1.50 6535MHz Pass AV 13.07598G 39.33 68.20 -28.87 3 Horizontal 316 1.50 6535MHz Pass PK 13.06812G 53.69 88.20 -34.51 3 Horizontal 316 1.50 6695MHz Pass AV 13.38732G 39.93 54.00 -14.07 3 Vertical 87 1.76 6695MHz Pass PK 13.3828G 55.12 74.00 -18.88 3 Vertical 87 1.76 6695MHz Pass AV 13.3953G 39.95 54.00 -14.05 3 Horizontal 9 2.51 6695MHz Pass PK 13.382G 54.17 74.00 -19.83 3 Horizontal 9 2.51 6875MHz Straddle 6.525-6.875GHz Pass AV 13.74028G 40.23 68.20 -27.97 3 Vertical 142 1.50 6875MHz Straddle 6.525-6.875GHz Pass PK 13.7405G 54.45 88.20 -33.75 3 Vertical 142 1.50 6875MHz Straddle 6.525-6.875GHz Pass AV 13.74284G 40.23 68.20 -27.97 3 Horizontal 73 2.01 6875MHz Straddle 6.525-6.875GHz Pass PK 13.74326G 55.50 88.20 -32.70 3 Horizontal 73 2.01 6895MHz Pass AV 13.7974G 40.28 68.20 -27.92 3 Vertical 356 1.50 6895MHz Pass PK 13.78986G 54.66 88.20 -33.54 3 Vertical 356 1.50 6895MHz Pass AV 13.79932G 40.26 68.20 -27.94 3 Horizontal 197 2.66 6895MHz Pass PK 13.78492G 55.58 88.20 -32.62 3 Horizontal 197 2.66 6995MHz Pass AV 13.98894G 40.89 68.20 -27.31 3 Vertical 318 2.86 6995MHz Pass PK 13.99152G 56.08 88.20 -32.12 3 Vertical 318 2.86 6995MHz Pass AV 13.99026G 40.86 68.20 -27.34 3 Horizontal 83 2.67 6995MHz Pass PK 13.9835G 56.17 88.20 -32.03 3 Horizontal 83 2.67 7095MHz Pass AV 14.18442G 41.71 68.20 -26.49 3 Vertical 301 1.50 7095MHz Pass PK 14.18522G 55.64 88.20 -32.56 3 Vertical 301 1.50 7095MHz Pass AV 14.18472G 41.63 68.20 -26.57 3 Horizontal 355 1.50 7095MHz Pass PK 14.19784G 56.15 88.20 -32.05 3 Horizontal 355 1.50 7115MHz Pass AV 7.1155G 92.28 Inf -Inf 3 Vertical 23 1.82 7115MHz Pass AV 7.125G 66.58 68.20 -1.62 3 Vertical 23 1.82 7115MHz Pass PK 7.1157G 101.96 Inf -Inf 3 Ver…

Text truncated - open the document above for the full version.

Test Report

FCC RADIO TEST REPORT Report No. : FR5N2105AE TEL : 886-3-656-9065 Page Number : 1 of 35 FAX : 886-3-656-9085 Issued Date : Apr. 09, 2026 Report Template No.: HE1-D1-1 Ver2.8 Report Version : 01 FCC ID: 2AVVV-A2 FCC RADIO TEST REPORT FCC ID : 2AVVV-A2 Equipment : Wi-Fi 7 Wall Plate Access Point Brand Name : meter Model Name : A2 Applicant : Meter, Inc. 548 Market St, PMB 22716 San Francisco CA 94104 USA Manufacturer : Meter Inc. 548 Market St, PMB 22716 San Francisco CA 94104 USA Standard : 47 CFR FCC Part 15.407 The product was received on Nov. 27, 2025, and testing was started from Jan. 30, 2026 and completed on Mar. 28, 2026. We, SPORTON INTERNATIONAL INC. Hsinhua Laboratory, would like to declare that the tested sample has been evaluated in accordance with the procedures given in ANSI C63.10-2020 + Cor.1-2023 + C63.10a-2024 + Errata to C63.10a-2024 and shown compliance with the applicable technical standards. The test results in this report apply exclusively to the tested model / sample. Without written approval of SPORTON INTERNATIONAL INC. Hsinhua Laboratory, the test report shall not be reproduced except in full. ___________________________________________ Approved by: Jackson Tsai __________________________________________ SDoC by: XXXXX SPORTON INTERNATIONAL INC. Hsinhua Laboratory No.52, Huaya 1st Rd., Guishan Dist., Taoyuan City 333411, Taiwan (R.O.C.) FCC RADIO TEST REPORT Report No. : FR5N2105AE TEL : 886-3-656-9065 Page Number : 2 of 35 FAX : 886-3-656-9085 Issued Date : Apr. 09, 2026 Report Template No.: HE1-D1-1 Ver2.8 Report Version : 01 FCC ID: 2AVVV-A2 Table of Contents History of this test report ................................................................................................................................. 3 Summary of Test Result................................................................................................................................... 4 1 General Description ............................................................................................................................. 5 1.1 Information .............................................................................................................................................. 5 1.2 Applicable Standards ........................................................................................................................... 11 1.3 Testing Location Information ................................................................................................................ 11 1.4 Measurement Uncertainty .................................................................................................................... 12 2 Test Configuration of EUT ................................................................................................................. 13 2.1 Test Channel Mode .............................................................................................................................. 13 2.2 The Worst Case Measurement Configuration ...................................................................................... 14 2.3 Support Equipment ............................................................................................................................... 17 2.4 Test Setup Diagram ............................................................................................................................. 18 3 Transmitter Test Result ..................................................................................................................... 19 3.1 AC Power-line Conducted Emissions .................................................................................................. 19 3.2 Emission Bandwidth ............................................................................................................................. 21 3.3 Maximum Equivalent Isotropically Radiated Power (E.I.R.P.) ............................................................. 22 3.4 Peak Power Spectral Density (E.I.R.P.) ............................................................................................... 25 3.5 Unwanted Emissions ............................................................................................................................ 28 3.6 Contention Based Protocol ................................................................................................................... 33 4 Test Equipment and Calibration Data .............................................................................................. 34 Appendix A. Test Results of AC Power-line Conducted Emissions Appendix B. Test Results of Emission Bandwidth Appendix C. Test Results of Maximum Equivalent Isotropically Radiated Power (E.I.R.P.) Appendix D. Test Results of Peak Power Spectral Density (E.I.R.P.) Appendix E. Test Results of Unwanted Emissions Appendix F. Test Results of Contention-Based Protocol Appendix G. Test Results of Radiated Emission Co-location Appendix H. Test Photos Photographs of EUT v01 FCC RADIO TEST REPORT Report No. : FR5N2105AE TEL : 886-3-656-9065 Page Number : 3 o…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Saied Haddad
[email protected]Fax: (510) 296-8995

Technical Contact

Meter Inc.Saied Haddad
[email protected]

548 Market St, PMB 22716 · San Francisco, 94104 · United States

Test Firm

Sporton International Inc. Hsinhua LaboratoryAlex Chen
[email protected]Fax: +886-3-327-0978

Technical Specifications

#Rule PartsFrequency RangePower Output
115E5.96 GHz - 7.12 GHz503.50 mW
Confidentiality
Long Term
Grant Notes
Power listed is EIRP. Device operates with specific antennas in MIMO configurations as described in this filing. The antennas used for this device must be installed to provide a separation distance of at least 46 cm from all persons and must not transmit simultaneously with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. Users must be provided with installation instructions and transmitter operating conditions for satisfying RF exposure compliance. This device has 20, 40, 80 and 160 MHz bandwidth modes. Device operation is limited to indoor use only.

Other Applications from Meter Inc.

2x2x2 Indoor Wi-Fi 7 Access Point - FCC ID 2AVVV-A1 - Meter Inc
2AVVV-A1

2x2x2 Indoor Wi-Fi 7 Access Point

Nov 26, 2025

Equipment Class

NII - Unlicensed National Information Infrastructure TX
Meter wireless access point with WiFi and Bluetooth - FCC ID 2AVVV-MW08 - Meter Inc
2AVVV-MW08

Meter wireless access point with WiFi and Bluetooth

Jul 16, 2023

Equipment Class

NII - Unlicensed National Information Infrastructure TX