TC003 Thermal Imaging Camera I User Manual EN I 5 Do not point the thermal imaging camera at the sun or other strong energy sources for long periods of time, otherwise there might be damage to the detector in the thermal imaging camera. Keep the thermal imaging camera away f rom water to avoid electricity leakage or short circuits. Do not touch the lens with your hands. Do not knock, pry, puncture, or scratch the lens. Do not disassemble the thermal imaging camera. Cautions About TC003 Read all instructions before use TOPDON's TC003 is an Android-based thermal imaging camera used for equipment inspection and maintenance. You can apply the camera in home heating, water leak detection, and agricultural protection. It can be used either on its own in standalone mode or in USB mode to work with a Windows-based computer. EN I 6 Figure 1.1.1 Section 1 Product Overview Buttons and Ports 12 3 5 4 6 EN I 7 ItemDescription Long press to power ON/OFF; short press to wake up/lock the screen. Whenever the screen lights up, long press to enable the thermal imaging software; after the software is enabled, short press to take a photo. Mounts the TC003 onto a tripod / / Used for charging, file transfer, OTG functions, or using the thermal imaging function on a computer. 1. Power Button 2. Thermal Imaging Button 3. Screw Hole (1/4-20 unc) 4. Speaker 5. Visible light camera, infrared camera, and flashlight 6. USB Type-C Port Notes: 1. With the OTG function, you can connect the TC003 unit to USB flash drives, industrial borescopes, oscilloscopes, and more. 2. To ensure the system runs smoothly, installation of non- TOPDON apps is blocked on the TC003 unit. If you need to install non-TOPDON apps, please contact support@topdon. com for help. EN I 8 Gestures and Shortcuts Swipe-Down Menu Figure 1.2.1 Swipe Swipe-Down Menu: Swipe down f rom the top of the screen to display the Swipe-Down Menu. This gives you instant access to Wi-Fi, Bluetooth, a flashlight, volume, screen brightness, screen projection, rotation, and screen recording (see Figure 1.2.2). Figure 1.2.2 EN I 9 Figure 1.2.3 TC003 Software Shortcuts Icon Description Returns to the previous page Returns to the Home screen Views opened apps Captures a screenshot EN I 10 TC003 Thermal Carrying Bag USER MANUAL Imaging Camera User Manual Section 2 What's in the Box? EN I 11 Section 3 Using TC003 in Standalone Mode Thermal Imaging Temperature Monitoring Open the TC003 app f rom the Home screen. Then tap Thermal Imaging to enter the thermal imaging screen. Alternatively, whenever the screen lights up, you can always long press the Thermal Imaging Button at the top right edge to enter the thermal imaging screen directly. In this module, real-time temperature data can be displayed in a graph, allowing you to intuitively observe the temperature changes. Tap "Generate Image", and select the desired monitoring type as prompted. Then, select the place to be monitored on the screen. Tap "Start Recording". Real-time temperature of the measured object will be displayed in a graph. 1. 2. Figure 3.1.1 EN I 12 Gallery To view the captured images and videos, tap "Gallery", or select the thumbnail image on the photo/video recording screen to access the Gallery. Figure 3.2.1 Figure 3.3.1 EN I 13 Temperature Correction To ensure accuracy of measurement in different scenarios, this module allows you to set Ambient Temperature, Distance to Spot and Emissivity in default mode, or add custom modes and set the corresponding parameters. Nine commonly used emissivity values are listed on the screen for reference. Please go to "Personal Information" and tap "Temperature Correction" to enter the setting screen. Figure 3.4.1 EN I 15 Section 4 Specifications Resolution of infrared camera Spectral range Pixel size NETD FOV IFOV Measurement range Measurement accuracy Measurement resolution Resolution of visible light camera Storage capacity Battery capacity 256*192 8 to 14 μm 12 μm < 40 mK 56°*42° 3.85 mrad -4 to 1,022°F (-20 to 550ºC) ±2ºC or ±2% of reading, the larger value shall prevail 0.1ºC 5 megapixels 2GB RAM + 32GB internal storage 5,000 mAh EN I 16 Section 5 FAQ While I'm using the thermal imaging function, why is there a clicking sound with a frozen screen, once every few dozens of seconds? As the temperature of the inf rared imaging camera changes slightly during use, to ensure measurement accuracy, a periodic internal temperature calibration is needed every a few dozens of seconds. The micro-motor controlled activation or deactivation of such internal calibration makes a clicking sound during which the screen f reezes for about one second. To turn off the internal calibration function, please open the TC003 app, go to Personal Information, and turn off Auto shutter. Can the TC003 detect objects underwater, through glass or a wall? No. Infrared detectors mainly detects 8 to 14 μm long-wave inf rared areas, and can only be used to measure surface temperature. Why is there a lower temperature reading when the device gets far from the object and a higher reading when the device gets closer to the object? Inf rared radiation attenuates when passing through the atmosphere. The longer the distance, the greater the attenuation. Thus, the accuracy of temperature measurement at a distance will decrease. To ensure accuracy of measurement, go to Personal Information > Temperature Correction > Distance to Spot, and input the actual distance (max: 5 meters) to get the corrected temperature. Is the TC003 compatible with iOS devices? No, the TC003 is ONLY compatible with Android devices and Windows computers. Why is the measured temperature not very precise? The temperature resolution of TC003 is ±2%. And the TC003 provides a normal temperature range of -4 to 302°F (-20 to 150ºC), and a high temperature range of 302° to 1022°F (150 to Q Q Q Q Q A A A A A EN I 17 550ºC). Please select the corresponding range in the app before measuring. What external factors will affect the infrared temperat…
Text truncated - open the document above for the full version.
TOPDONTECHNOLOGYCo.,Ltd. Address:Unit200520/F,QianhaiShimaoTower,QianhaiShenzhen-HongkongCooperationZone ShenzhenChina Date:2023-03-22 FederalCommunicationsCommission AuthorizationandEvaluationDivision 1435OaklandMillsRoad Columbia,MD21046 Ref:AttestationStatementsPart2.911(d)(7)Filing TOPDONTECHNOLOGYCo.,Ltd.certifiesthat,asofthedateofthefilingoftheapplication, TOPDONUSAINC.isourdesignatedU.S.agentforserviceofprocessfortheabove referencedFCCID.TOPDONTECHNOLOGYCo.,Ltd.acceptstomaintainanagentforno lessthanoneyearafterthegranteehasterminatedallmarketingandimportationorthe conclusionofanyCommission-relatedproceedinginvolvingtheequipment. TOPDONUSAINC.accepts,asofthedateofthefilingoftheapplication,theobligationof thedesignatedU.S.agentforserviceofprocessforrepresentativeonbehalfoftheApplicant notedbelowforallfutureFCCIDcertification. DesignatedU.S.AgentInformation: Name:TOPDONUSAINC. Address:400CommonsWay,SuiteARockaway,NewJersey07866. FRN:0033407057 ContactPerson:HlinYang Tel.:(183)369-22766 Email:[email protected] Sincerely SignedonbehalfofTOPDON TECHNOLOGYCo.,Ltd SignedonbehalfofTOPDONUSAINC Name:HlinYangName:HlinYang Title:Manager Title:Manager Date:2023-3-14 Date:2023-3-14
TOPDON TECHNOLOGY Co., Ltd. Date: 2023-3-24 Product Model Number: TC003 FCC ID: 2AVYW-TC003 To whom it may concern, Re: Product Certification Representative Authorization Letter We authorize QAI Laboratories Ltd. 3980 North Fraser Way, Burnaby B.C. Canada VSJ 5K5 to act on ou「 behalf on all matte「s concerning the above named equipment. This shall include the following: • Testing • Approval applications and procedures We declare that ORGANIZATION. is allowed to forward all information related to the approval project to the applied certification body and to the notification entities and to discuss any issues concerning the approval application. Any and all acts carried out by ORGANIZATION. on our behalf shall have the same effect as acts of our own. By: H lin Y a ng Hlu\(<飞 Contact Listed on FCC esbite Title: Manager Email: [email protected] Telephone: +86 75523211152 On behalf of: TOPDON TECHNOLOGY Co., Ltd. Effective Date: April 2, 2020 Revision Date QSF 7.6牛8- Agent Authorization Letter Template Revision: 0 Page I of I
Externalphotos
Internalphotos ANT
ShenzhenHuaxiaTestingTechnologyCo.,Ltd 1F.,BlockAofTongshengTechnologyBuilding,HuahuiRoad,DalangStreet,LonghuaDistrict, Shenzhen,China Telephone:+86-755-26648640 Fax:+86-755-26648637 Website:www.cqa-cert.com ReportTemplateVersion:V05 ReportTemplateRevisionDate:2021-11-03 RFExposureEvaluationReport Thetestreportiseffectiveonlywithbothsignatureandspecializedstamp,Theresult(s)showninthisreportreferonlyto thesample(s)tested.WithoutwrittenapprovalofCQA,thisreportcan’tbereproducedexceptinfull. ReportNo.:CQASZ20230300321E-03 Applicant: TOPDONTECHNOLOGYCo.,Ltd. AddressofApplicant: Unit200520/F,QianhaiShimaoTower,QianhaiShenzhen-Hongkong CooperationZoneShenzhenChina EquipmentUnderTest(EUT): EUTName: ThermalImagingCamera ModelNo.: TC003 TestModelNo.: TC003 BrandName: FCCID:2AVYW-TC003 Standards: 47CFRPart1.1307 47CFRPart2.1093 KDB447498D04InterimGeneralRFExposureGuidancev01 DateofReceipt:2023-03-10 DateofTest: 2023-03-10to2023-03-17 DateofIssue:2023-03-23 TestResult:PASS* *Intheconfigurationtested,theEUTcompliedwiththestandardsspecifiedabove. TestedBy: (LewisZhou) ReviewedBy: (TimoLei) ApprovedBy: (JackAi) ShenzhenHuaxiaTestingTechnologyCo.,Ltd. ReportNo.:CQASZ20230300321E-03 Page:2of8 1Version RevisionHistoryOfReport ReportNo.Version Description IssueDate CQASZ20230300321E-03Rev.01 Initialreport 2023-03-23 ShenzhenHuaxiaTestingTechnologyCo.,Ltd. ReportNo.:CQASZ20230300321E-03 Page:3of8 2Contents Page 1VERSION............................................................................................................................................................................2 2CONTENTS........................................................................................................................................................................3 ..................................................................................................................................................................................................3 3GENERALINFORMATION..............................................................................................................................................4 3.1CLIENTINFORMATION...................................................................................................................................................4 3.2GENERALDESCRIPTIONOFEUT...................................................................................................................................4 3.3GENERALDESCRIPTIONOFBT......................................................................................................................................4 3.4GENERALDESCRIPTIONOF2.4GWIFICLASSIC...........................................................................................................4 4SAREVALUATION...........................................................................................................................................................6 4.1RFEXPOSURECOMPLIANCEREQUIREMENT.................................................................................................................6 4.1.1StandardRequirement......................................................................................................................................6 4.1.2Limits....................................................................................................................................................................6 4.1.3EUTRFExposure..............................................................................................................................................8 ShenzhenHuaxiaTestingTechnologyCo.,Ltd. ReportNo.:CQASZ20230300321E-03 Page:4of8 3GeneralInformation 3.1ClientInformation Applicant: TOPDONTECHNOLOGYCo.,Ltd. AddressofApplicant: Unit200520/F,QianhaiShimaoTower,QianhaiShenzhen-Hongkong CooperationZoneShenzhenChina Manufacturer: TOPDONTECHNOLOGYCo.,Ltd. AddressofManufacturer: Unit200520/F,QianhaiShimaoTower,QianhaiShenzhen-Hongkong CooperationZoneShenzhenChina Factory: TOPDONTECHNOLOGYCo.,Ltd. AddressofFactory: Unit200520/F,QianhaiShimaoTower,QianhaiShenzhen-Hongkong CooperationZoneShenzhenChina 3.2GeneralDescriptionofEUT ProductName: ThermalImagingCamera ModelNo.: TC003 TestModelNo.: TC003 TradeMark: SoftwareVersion: TOPDONUIV1.12 HardwareVersion: TC003_V0_3 PowerSupply: Li-ionbatteryDC3.7V5050mAh,ChargebyDC5Vforadapter 3.3GeneralDescriptionofBT OperationFrequency:2402MHz~2480MHz ModulationType:GFSK TransferRate:1Mbps NumberofChannel:79 ProductType:MobilePortable AntennaType: FPCantenna AntennaGain: 1.65dBi 3.4GeneralDescriptionof2.4GWIFIClassic OperationFrequency: 2412MHz~2462MHz TypeofModulation: IEEEfor802.11b:DSSS(CCK,DQPSK,DBPSK) IEEEfor802.11g:OFDM(64QAM,16QAM,QPSK,BPSK) IEEEfor802.11n(HT20):OFDM(64QAM,16QAM,QPSK,BPSK) NumberofChannel: IEEE802.11b/g,IEEE802.11nHT20:11Channels ChannelSeparation: 5MHz TransferRate: IEEEfor802.11b: 1Mbps/2Mbps/5.5Mbps/11Mbps IEEEfor802.11g: 6Mbps/9Mbps/12Mbps/18Mbps/24Mbps/36Mbps/48Mbps/54Mbps IEEEfor802.11n(HT20): ShenzhenHuaxiaTestingTechnologyCo.,Ltd. ReportNo.:CQASZ20230300321E-03 Page:5of8 6.5Mbps/13Mbps/19.5Mbps/26Mbps/39Mbps/52Mbps/58.5Mbps/65Mbps SampleType: MobilePortable AntennaType:FPCantenna AntennaGain:1.65dBi ShenzhenHuaxiaTestingTechnologyCo.,Ltd. ReportNo.:CQASZ20230300321E-03 Page:6of8 4SAREvaluation 4.1RFExposureComplianceRequirement 4.1.1StandardRequirement 447498D04InterimGeneralRFExposureGuidancev01 3.2.SARTestReductionGuidance SARtestreductionprocedures[Glossary]allowusingaparticularsetoftestdataasrepresentative ofother,similar,testconditions.Thismaybeappliedfordatawithindifferenttestpositions(e.g.body, head,extremity),wirelessmodes(e.g.Wi-Fi,cellular),andfrequencybands.Thistestreductionprocess providesfortheuseoftestdataforonespecificchannel,whilereferencingtothosedatafordemonstrating complianceinotherrequiredchannelsforeachtestpositionofanexposurecondition,withintheoperating modeofafrequencyband.Thisislimitedspecificallytowhenthereported1-gor10-gSARforthemid-…
Text truncated - open the document above for the full version.
ShenzhenHuaxiaTestingTechnologyCo.,Ltd. 1F.,BlockAofTongshengTechnologyBuilding,HuahuiRoad,DalangStreet,LonghuaDistrict, Shenzhen,China Telephone:+86-755-26648640 Fax:+86-755-26648637 Website:www.cqa-cert.com ReportTemplateVersion:V05 ReportTemplateRevisionDate:2021-11-03 TestReport Thetestreportiseffectiveonlywithbothsignatureandspecializedstamp,Theresult(s)showninthisreportreferonlyto thesample(s)tested.WithoutwrittenapprovalofCQA,thisreportcan’tbereproducedexceptinfull. ReportNo.:CQASZ20230300321E-01 Applicant: TOPDONTECHNOLOGYCo.,Ltd. AddressofApplicant: Unit200520/F,QianhaiShimaoTower,QianhaiShenzhen-Hongkong CooperationZoneShenzhenChina EquipmentUnderTest(EUT): Product: ThermalImagingCamera ModelNo.: TC003 TestModelNo.: TC003 BrandName: FCCID: 2AVYW-TC003 Standards:47CFRPart15,SubpartC DateofReceipt:2023-03-10 DateofTest: 2023-03-10to2023-03-17 DateofIssue:2023-03-23 TestResult:PASS* *Intheconfigurationtested,theEUTcompliedwiththestandardsspecifiedabove. TestedBy: (LewisZhou) ReviewedBy: (TimoLei) ApprovedBy: (JackAi) ShenzhenHuaxiaTestingTechnologyCo.,Ltd. ReportNo.:CQASZ20230300321E-01 Page:2of61 1Version RevisionHistoryOfReport ReportNo.Version Description IssueDate CQASZ20230300321E-01Rev.01 Initialreport 2023-03-23 ShenzhenHuaxiaTestingTechnologyCo.,Ltd. ReportNo.:CQASZ20230300321E-01 Page:3of61 2TestSummary TestItemTestRequirementTestmethodResult AntennaRequirement 47CFRPart15,SubpartCSection 15.203/15.247(c) ANSIC63.10(2013)PASS ACPowerLineConducted Emission 47CFRPart15,SubpartCSection 15.207 ANSIC63.10(2013)PASS ConductedPeakOutput Power 47CFRPart15,SubpartCSection 15.247(b)(1) ANSIC63.10(2013)PASS 20dBOccupiedBandwidth 47CFRPart15,SubpartCSection 15.247(a)(1) ANSIC63.10(2013)PASS CarrierFrequencies Separation 47CFRPart15,SubpartCSection 15.247(a)(1) ANSIC63.10(2013)PASS HoppingChannelNumber 47CFRPart15,SubpartCSection 15.247(a)(1) ANSIC63.10(2013)PASS DwellTime 47CFRPart15,SubpartCSection 15.247(a)(1) ANSIC63.10(2013)PASS PseudorandomFrequency HoppingSequence 47CFRPart15,SubpartCSection 15.247(b)(4) ANSIC63.10(2013)PASS Band-edgeforRF ConductedEmissions 47CFRPart15,SubpartCSection 15.247(d) ANSIC63.10(2013)PASS RFConductedSpurious Emissions 47CFRPart15,SubpartCSection 15.247(d) ANSIC63.10(2013)PASS RadiatedSpurious emissions 47CFRPart15,SubpartCSection 15.205/15.209 ANSIC63.10(2013)PASS Restrictedbandsaround fundamentalfrequency (RadiatedEmission) 47CFRPart15,SubpartCSection 15.205/15.209 ANSIC63.10(2013)PASS ShenzhenHuaxiaTestingTechnologyCo.,Ltd. ReportNo.:CQASZ20230300321E-01 Page:4of61 3Contents Page 1VERSION..........................................................................................................................................................................2 2TESTSUMMARY............................................................................................................................................................3 3CONTENTS......................................................................................................................................................................4 4GENERALINFORMATION...........................................................................................................................................5 4.1CLIENTINFORMATION.................................................................................................................................................5 4.2GENERALDESCRIPTIONOFEUT.................................................................................................................................5 4.3ADDITIONALINSTRUCTIONS........................................................................................................................................7 4.4TESTENVIRONMENT...................................................................................................................................................8 4.5DESCRIPTIONOFSUPPORTUNITS...............................................................................................................................8 4.6STATEMENTOFTHEMEASUREMENTUNCERTAINTY....................................................................................................9 4.7TESTLOCATION........................................................................................................................................................10 4.8TESTFACILITY..........................................................................................................................................................10 4.9ABNORMALITIESFROMSTANDARDCONDITIONS......................................................................................................10 4.10OTHERINFORMATIONREQUESTEDBYTHECUSTOMER..........................................................................................10 4.11EQUIPMENTLIST.....................................................................................................................................................11 5TESTRESULTSANDMEASUREMENTDATA.....................................................................................................12 5.1ANTENNAREQUIREMENT..........................................................................................................................................12 5.2CONDUCTEDEMISSIONS............................................................................................................................................13 5.3CONDUCTEDPEAKOUTPUTPOWER.........................................................................................................................17 5.420DBOCCUPYBANDWIDTH......................................................................................................................................21 5.5CARRIERFREQUENCIESSEPARATION........................................................................................................................24 5.6HOPPINGCHANNELNUMBER............................................................…
Text truncated - open the document above for the full version.
ShenzhenHuaxiaTestingTechnologyCo.,Ltd. ReportNo.:CQASZ20230300321E-01 Page:51of61 5.11.2TransmitterEmissionabove1GHz Worsecasemode:GFSK(DH5)Testchannel:Lowest Frequency Meter Reading Factor Emission Level LimitsOver Detector Type Ant.Pol. (MHz)(dBμV)(dB)(dBμV/m)(dBμV/m)(dB) H/V 239053.90-9.244.7074-29.30PeakH 240055.34-9.3945.9574-28.05PeakH 480451.30-4.3346.9774-27.03PeakH 720650.831.0151.8474-22.16PeakH 239053.73-9.244.5374-29.47PeakV 240055.71-9.3946.3274-27.68PeakV 480454.14-4.3349.8174-24.19PeakV 720649.361.0150.3774-23.63PeakV Worsecasemode:GFSK(DH5)Testchannel:Middle Frequency Meter Reading Factor Emission Level LimitsOver Detector Type Ant.Pol. (MHz)(dBμV)(dB)(dBμV/m)(dBμV/m)(dB) H/V 488251.57-4.1147.4674-26.54peakH 732348.371.5149.8874-24.12peakH 488251.83-4.1147.7274-26.28peakV 732350.701.5152.2174-21.79peakV Worsecasemode:GFSK(DH5)Testchannel:Highest Frequency Meter ReadingFactor Emission LevelLimitsOver Detector TypeAnt.Pol. (MHz)(dBμV)(dB)(dBμV/m)(dBμV/m)(dB) H/V 2483.555.19-9.2945.9074-28.10PeakH 496053.02-4.0448.9874-25.02PeakH 744049.881.5751.4574-22.55PeakH 2483.554.22-9.2944.9374-29.07PeakV 496050.35-4.0446.3174-27.69PeakV 744049.721.5751.2974-22.71PeakV Remark: 1)ThefieldstrengthiscalculatedbyaddingtheAntennaFactor,CableFactor&Preamplifier.Thebasic equationwithasamplecalculationisasfollows: FinalTestLevel=ReceiverReading+AntennaFactor+CableFactor–PreamplifierFactor 2)Scanfrom9kHzto25GHz,thedisturbanceabove10GHzandbelow30MHzwasverylow.Asshownin thissection,forfrequenciesabove1GHz,thefieldstrengthlimitsarebasedonaveragelimits.However, thepeakfieldstrengthofanyemissionshallnotexceedthemaximumpermittedaveragelimitsspecified abovebymorethan20dBunderanyconditionofmodulation.So,onlythepeakmeasurementswere showninthereport. ShenzhenHuaxiaTestingTechnologyCo.,Ltd. ReportNo.:CQASZ20230300321E-01 Page:52of61 3) 6Photographs-EUTTestSetup 6.1RadiatedEmission 9KHz~30MHz: 30MHz~1GHz: ShenzhenHuaxiaTestingTechnologyCo.,Ltd. ReportNo.:CQASZ20230300321E-01 Page:53of61 Above1GHz: 6.2ConductedEmission ShenzhenHuaxiaTestingTechnologyCo.,Ltd. ReportNo.:CQASZ20230300321E-01 Page:54of61 7Photographs-EUTConstructionalDetails ShenzhenHuaxiaTestingTechnologyCo.,Ltd. ReportNo.:CQASZ20230300321E-01 Page:55of61 ShenzhenHuaxiaTestingTechnologyCo.,Ltd. ReportNo.:CQASZ20230300321E-01 Page:56of61 ShenzhenHuaxiaTestingTechnologyCo.,Ltd. ReportNo.:CQASZ20230300321E-01 Page:57of61 ShenzhenHuaxiaTestingTechnologyCo.,Ltd. ReportNo.:CQASZ20230300321E-01 Page:58of61 ShenzhenHuaxiaTestingTechnologyCo.,Ltd. ReportNo.:CQASZ20230300321E-01 Page:59of61 ShenzhenHuaxiaTestingTechnologyCo.,Ltd. ReportNo.:CQASZ20230300321E-01 Page:60of61 ShenzhenHuaxiaTestingTechnologyCo.,Ltd. ReportNo.:CQASZ20230300321E-01 Page:61of61 ***ENDOFREPORT***
1Photographs-EUTTestSetup 1.1RadiatedEmission 9KHz~30MHz: 30MHz~1GHz: Above1GHz: 1.2ConductedEmission
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 1.30 mW |

Handheld Thermal Imaging Camera
Equipment Class
DTS - Digital Transmission System
Handheld Thermal Imaging Camera
Equipment Class
DTS - Digital Transmission System
Handheld Thermal lmaging Camera
Equipment Class
DTS - Digital Transmission System
Handheld Thermal lmaging Camera
Equipment Class
DTS - Digital Transmission System
Professional Diagnostic Tool
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter