Application Details

Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Date of Grant
Aug 22, 2024
Application Purpose
Original Equipment
Date of Application
Aug 22, 2024
Equipment Note
Smart Diagnostic System
Frequency Range
2402.00000000 - 2480.00000000
Company
Shenzhen Xtooltech Intelligent Co., Ltd
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗
↗
↗
↗
↗
↗

Test Report

↗
↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

User Manual P701 Smart Diagnostic System HVIN:P701 Note:LE-LAN devices are restricted to indoor operation only in the band 5150-5250 MHz Remarque: les dispositifs LE-LAN ne sont limités au fonctionnement intérieur que dans la bande 5150-5250 mhz Shenzhen Xtooltech Intelligent Co., LTD Please read this user manual carefully before using the Smart Diagnostic System, referred to as the “Scan Tool” throughout this document. When reading the manual, please pay attention to the words “Note” or “Caution”, and read them carefully for appropriate operation. OPERATION INSTRUCTIONS For safe operation, please follow the instructions below:  Keep the device away from heat or fumes when in use.  If the vehicle battery contains acid, please keep your hands and skin or fire sources away from the battery during testing.  The exhaust gas of the vehicle contains harmful chemicals. Please ensure adequate ventilation.  Do not touch the vehicle cooling system components or exhaust manifolds when the engine is running due to the high temperatures reached.  Make sure the car is securely parked, Neutral is selected or the selector is at the P or N position to prevent the vehicle from moving when the engine starts.  Make sure the (DLC) Diagnostic Link Connector is functioning properly before starting the test to avoid damage to the Diagnostic Computer.  Do not switch off the power or unplug the connectors during testing.  Doing so may damage the ECU (Electronic Control Unit) and/or the Diagnostic Computer. CAUTIONS!  Avoid shaking, dropping or dismantling the scan tool as it may damage the internal components.  Use only your fingertips to touch the LCD screen. Hard or sharp objects may damage the scan tool.  Do not use excessive force;  Do not expose the screen to strong sunlight for a long period.  Please keep the scan tool away from water and moisture.  Store and use the scan tool only within the temperature ranges identified in the Technical Specifications section.  Keep the unit away from strong magnetic fields. AFTERSALES-SERVICES E-Mail: [email protected] Tel: +86 755 21670995 or +86 755 86267858 (China) Official Website: www.xtooltech.com Catalogue Operation Instructions ....................................................................................................................... 2 Cautions! ........................................................................................................................................... 2 1. General Introduction.....................................................................................................................4 2. Diagnostics ................................................................................................................................... 6 3. Special Functions ........................................................................................................................ 18 3.2 OIL RESET ...................................................................................................................... 21 3.3 EPB ................................................................................................................................... 23 3.4 SAS ................................................................................................................................... 25 3.5 BMS RESET .................................................................................................................... 27 3.5 INJECTOR CODING ....................................................................................................... 28 3.7 DPF REGENERATION ................................................................................................... 31 3.8 TPMS RESET .................................................................................................................. 34 4. Report ......................................................................................................................................... 38 5. Update & Factory Reset..............................................................................................................41 6. Remote Assistance .....................................................................................................................43 7. Appendix....................................................................................................................................44 1. GENERAL INTRODUCTION The XTOOL P701 smart diagnostic system (referred to as the “Scan Tool”) is an advanced scanning tool based on the Android operating system. It supports multiple languages and is suitable for different countries and regions. The advantage of this OBD-II (On-Board Diagnostics version 2) scanner is its comprehensive functions and its ability to quickly provide the user with more accurate diagnostic information. TABLET VEHICLE CONNECTION Wired Connection Precautions for Diagnosis 1. The voltage range on the car: +9~+36V DC; 2. When testing some special functions, the operator must operate according to the prompts and meet the test conditions. For some models [special functions], the conditions that need to be met are: engine water temperature 80 °C~105 °C, turn off headlights and air conditioners, keep the accelerator pedal in the released position, etc.; 3. The electronic control systems of different models are very complicated. If you encounter situations where it is impossible to test or a large amount of test data is abnormal, you can search for the ECU of the vehicle and select the menu for the model on the ECU nameplate; 4. If the vehicle type or electronic control system to be tested is not found in the diagnostic function, please upgrade the vehicle diagnostic software to the latest version using the Updates menu or consult the XTOOL technical service department; 5. Only wiring harnesses provided by XTOOL and designed for the device are permitted to be used with this device to avoid damage to the vehicle or …

Text truncated - open the document above for the full version.

Attestation Statements

Shenzhen Xtooltech Intelligent Co., Ltd Federal Communications Commission Authorization and Evaluation Division Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MD 21046 8/16/2024 U.S. Agent Designation Shenzhen Xtooltech Intelligent Co., Ltd acknowledges their consent for the following contact located in the United States to act as their agent for service of process for the equipment for which authorization is sought (FCC ID: 2AW3IP701): Name and company of U.S. agent: TianHeng Consulting, LLC Physical U.S. address of agent: 30 N Gould St Ste 44116, Sheridan, WY 82801, United States FRN of U.S. agent: 0033401258 Email address of U.S. agent: [email protected] TianHeng Consulting, LLC acknowledges their obligation to accept service of process on behalf of Shenzhen Xtooltech Intelligent Co., Ltd. Shenzhen Xtooltech Intelligent Co., Ltd with the FRN 0029799749 accepts its obligation to maintain an agent for service of process in the United States for no less than one year after either the grantee has permanently terminated all marketing and importation of the applicable equipment within the U.S., or the conclusion of any Commission-related administrative or judicial proceeding involving the equipment, whichever is later. By signing this form, we confirm the above and that we are aware of the application requirements listed under § 2.911(d)(7). The information provided in this letter is based on the referenced rule parts of Title 47 of the CFR as well as KDB 986446 D01. An expiration date for this letter does not exist. In case the U.S. agent changes, the grantee is obligated to notify the FCC within 30 days via the granting TCB. Sincerely, Signature Darby Tan Overseas Sales Director Shenzhen Xtooltech Intelligent Co., Ltd Signature Yingzhi Chen President TianHeng Consulting, LLC 48_[model] US_Agent_2.911(d)(7) - U, V05

External Photos

Page 1 of 5 FCC ID: 2AW3IP701 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity External Photos of the EUT Fig. 1 Fig. 2 Page 2 of 5 FCC ID: 2AW3IP701 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 3 Fig. 4 Page 3 of 5 FCC ID: 2AW3IP701 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 5 Fig. 6 Page 4 of 5 FCC ID: 2AW3IP701 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 7 Fig. 8 Page 5 of 5 FCC ID: 2AW3IP701 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 9 Fig. 10

ID Label/Location Info

Page 1 of 1 FCC ID: 2AW3IP701 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Label and Location Size: L: 44.70mm*W: 29.70mm Material: tagboard Glue: adhesive sticker Font color: white Label color: black& silver polyester (Size: L 44.7mm x W 29.7mm) Label Location Smart Diagnostic System Test Model: P701 FCC ID: 2AW3IP701 L W

Internal Photos

Page 1 of 10 FCC ID: 2AW3IP701 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Internal Photos of the EUT Fig. 1 Fig. 2 Page 2 of 10 FCC ID: 2AW3IP701 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 3 Fig. 4 Page 3 of 10 FCC ID: 2AW3IP701 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 5 Fig. 6 Page 4 of 10 FCC ID: 2AW3IP701 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 7 Fig. 8 Page 5 of 10 FCC ID: 2AW3IP701 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 9 Fig. 10 Page 6 of 10 FCC ID: 2AW3IP701 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 11 Fig. 12 Page 7 of 10 FCC ID: 2AW3IP701 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 13 Fig. 14 Page 8 of 10 FCC ID: 2AW3IP701 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 15 Fig. 16 Page 9 of 10 FCC ID: 2AW3IP701 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 17 Fig. 18 BT/WIFI ANT Page 10 of 10 FCC ID: 2AW3IP701 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 19

RF Exposure Info

Page 1 of 5 FCC ID: 2AW3IP701 Report No.: LCSA07114122EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Appendix A Detailed System Check Results 1. System Performance Check System Performance Check 2450 MHz Head System Performance Check 5250 MHz Head System Performance Check 5600 MHz Head System Performance Check 5750 MHz Head Page 2 of 5 FCC ID: 2AW3IP701 Report No.: LCSA07114122EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Date: 2024/7/23 Test Laboratory: LCS-SAR Lab System Check 2450 MHz DUT: D2450V2; Type: D2450V2; Serial: 808 Communication System: UID 0, CW (0); Frequency: 2450 MHz;Duty Cycle: 1:1 Medium parameters used: f = 2450 MHz; σ = 1.865 S/m; ε r = 38.745; ρ = 1000 kg/m 3 Phantom section: Flat Section DASY Configuration:  Probe: EX3DV4 - SN3805; ConvF(7.42, 7.42, 7.42); Calibrated: 2023/11/23;  Sensor-Surface: 2mm (Mechanical Surface Detection)  Electronics: DAE3 Sn373; Calibrated: 2024/1/3  Phantom: ELI v5.0; Type: ELI; Serial: 2010  DASY52 52.8.8(1222); SEMCAD X 14.6.10(7331) Configuration/Unnamed procedure/Area Scan (4x8x1): Measurement grid: dx=12mm, dy=12mm Maximum value of SAR (measured) = 14.5 W/kg Configuration/Unnamed procedure/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Reference Value = 66.52 V/m; Power Drift = -0.12 dB Peak SAR (extrapolated) = 25.8 W/kg SAR(1 g) = 12.57 W/kg; SAR(10 g) = 5.69 W/kg Maximum value of SAR (measured) = 15.1 W/kg 0 dB = 15.1 W/kg = 11.79 dBW/kg Page 3 of 5 FCC ID: 2AW3IP701 Report No.: LCSA07114122EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Date: 2024/8/2 Test Laboratory: LCS-SAR Lab System Check 5250 MHz DUT: D5GHzV2; Type: D5GHzV2; Serial: 1046 Communication System: UID 0, CW (0); Frequency: 5250 MHz;Duty Cycle: 1:1 Medium parameters used: f = 5250 MHz; σ = 4.574 S/m; ε r = 35.221; ρ = 1000 kg/m 3 Phantom section: Flat Section DASY Configuration:  Probe: EX3DV4 - SN3805; ConvF(5.38, 5.38, 5.38); Calibrated: 2023/11/23;  Sensor-Surface: 2mm (Mechanical Surface Detection)  Electronics: DAE3 Sn373; Calibrated: 2024/1/3  Phantom: ELI v5.0; Type: ELI; Serial: 2010  DASY52 52.8.8(1222); SEMCAD X 14.6.10(7331) Configuration/Unnamed procedure/Area Scan (10x10x1): Measurement grid: dx=10mm, dy=10mm Maximum value of SAR (measured) = 15.2 W/kg Configuration/Unnamed procedure/Zoom Scan (7x7x12)/Cube 0: Measurement grid: dx=4mm, dy=4mm, dz=2mm Reference Value = 54.32 V/m; Power Drift = 0.10 dB Peak SAR (extrapolated) = 28.9 W/kg SAR(1 g) = 7.55 W/kg; SAR(10 g) = 2.36 W/kg Maximum value of SAR (measured) = 16.6 W/kg 0 dB = 16.6 W/kg = 12.20 dBW/kg Page 4 of 5 FCC ID: 2AW3IP701 Report No.: LCSA07114122EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Date: 2024/8/2 Test Laboratory: LCS-SAR Lab System Check 5600MHz DUT: D5GHzV2; Type: D5GHzV2; Serial: 1046 Communication System: UID 0, CW (0); Frequency: 5600 MHz;Duty Cycle: 1:1 Medium parameters used: f = 5600 MHz; σ = 5.124 S/m; ε r = 36.112; ρ = 1000 kg/m 3 Phantom section: Flat Section DASY Configuration:  Probe: EX3DV4 - SN3805; ConvF(4.75, 4.75, 4.75); Calibrated: 2023/11/23;  Sensor-Surface: 2mm (Mechanical Surface Detection)  Electronics: DAE3 Sn373; Calibrated: 2024/1/3  Phantom: ELI v5.0; Type: ELI; Serial: 2010  DASY52 52.8.8(1222); SEMCAD X 14.6.10(7331) Configuration/Unnamed procedure/Area Scan (10x10x1): Measurement grid: dx=10mm, dy=10mm Maximum value of SAR (measured) = 26.3 W/kg Configuration/Unnamed procedure/Zoom Scan (7x7x12)/Cube 0: Measurement grid: dx=4mm, dy=4mm, dz=2mm Reference Value = 78.52 V/m; Power Drift = 0.06 dB Peak SAR (extrapolated) = 36.9 W/kg SAR(1 g) = 8.35 W/kg; SAR(10 g) = 2.21 W/kg Maximum value of SAR (measured) = 25.8 W/kg 0 dB = 25.8 W/kg = 14.12 dBW/kg Page 5 of 5 FCC ID: 2AW3IP701 Report No.: LCSA07114122EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Date: 2024/8/2 Test Laboratory: LCS-SAR Lab System Check 5750 MHz DUT: D5GHzV2; Type: D5GHzV2; Serial: 1046 Communication System: UID 0, CW (0); Frequency: 5750 MHz;Duty Cycle: 1:1 Medium parameters used: f = 5750 MHz; σ = 5.421 S/m; ε r = 36.021; ρ = 1000 kg/m 3 Phantom section: Flat Section DASY Configuration:  Probe: EX3DV4 - SN3805; ConvF(4.88, 4.88, 4.88); Calibrated: 2023/11/23;  Sensor-Surface: 2mm (Mechanical Surface Detection)  Electronics: DAE3 Sn373; Calibrated: 2024/1/3  Phantom: ELI v5.0; Type: ELI; Serial: 2010  DASY52 52.8.8(1222); SEMCAD X 14.6.10(7331) Configuration/Unnamed procedure/Area Scan (10x10x1): Measurement grid: dx=10mm, dy=10mm Maximum value of SAR (measured) = 11.5 W/kg Configuration/Unnamed procedure/Zoom Scan (7x7x12)/Cube 0: Measurement grid: dx=4mm, dy=4mm, dz=2mm Reference Value = 62.74 V/m; Power Drift = 0.17 dB Peak SAR (extrapolated) = 31.0 W/kg SAR(1 g) = 8.19 W/kg; SAR(10 g) = 2.25 W/kg Maximum value of SAR (measured) = 12.6…

Text truncated - open the document above for the full version.

RF Exposure Info

Page 1 of 6 FCC ID: 2AW3IP701 Report No.: LCSA07114122EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Appendix B Detailed Test Results 1. WIFI WIFI 2.4GHz for Body WIFI 5.2GHz for Body WIFI 5.3GHz for Body WIFI 5.5GHz for Body WIFI 5.8GHz for Body Page 2 of 6 FCC ID: 2AW3IP701 Report No.: LCSA07114122EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Date: 2024/7/23 Test Laboratory: LCS-SAR Lab WIFI 2.4G 802.11b 11CH Rear side 0mm DUT: Smart Diagnostic System; Type: P701; Serial: A240711105-1 Communication System: UID 0, WIFI 2.4GHz (0); Frequency: 2462 MHz;Duty Cycle: 1:1.008 Medium parameters used: f = 2462 MHz; σ = 1.752 S/m; ε r = 39.666; ρ = 1000 kg/m 3 Phantom section: Flat Section DASY Configuration:  Probe: EX3DV4 - SN3805; ConvF(7.42, 7.42, 7.42); Calibrated: 2023/11/23;  Sensor-Surface: 2mm (Mechanical Surface Detection)  Electronics: DAE3 Sn373; Calibrated: 2024/1/3  Phantom: ELI v5.0; Type: ELI; Serial: 2010  DASY52 52.8.8(1222); SEMCAD X 14.6.10(7331) Configuration/Unnamed procedure/Area Scan (11x13x1): Measurement grid: dx=12mm, dy=12mm Maximum value of SAR (measured) = 0.524 W/kg Configuration/Unnamed procedure/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Reference Value = 6.541 V/m; Power Drift = -0.11 dB Peak SAR (extrapolated) = 1.21 W/kg SAR(1 g) = 0.478 W/kg; SAR(10 g) = 0.298 W/kg Maximum value of SAR (measured) = 0.511 W/kg 0 dB = 0.511 W/kg = -2.92 dBW/kg Page 3 of 6 FCC ID: 2AW3IP701 Report No.: LCSA07114122EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Date: 2024/8/2 Test Laboratory: LCS-SAR Lab WIFI 5.2G 802.11a 48CH Body Rear 0mm DUT: Smart Diagnostic System; Type: P701; Serial: A240711105-1 Communication System: UID 0, WIFI 5GHz (0); Frequency: 5240 MHz;Duty Cycle: 1:1.058 Medium parameters used: f = 5240 MHz; σ = 4.745 S/m; ε r = 35.621; ρ = 1000 kg/m 3 Phantom section: Flat Section DASY Configuration:  Probe: EX3DV4 - SN3805; ConvF(5.38, 5.38, 5.38); Calibrated: 2023/11/23;  Sensor-Surface: 2mm (Mechanical Surface Detection)  Electronics: DAE3 Sn373; Calibrated: 2024/1/3  Phantom: ELI v5.0; Type: ELI; Serial: 2010  DASY52 52.8.8(1222); SEMCAD X 14.6.10(7331) Configuration/Unnamed procedure/Area Scan (12x15x1): Measurement grid: dx=10mm, dy=10mm Maximum value of SAR (measured) = 0.521 W/kg Configuration/Unnamed procedure/Zoom Scan (7x7x12)/Cube 0: Measurement grid: dx=4mm, dy=4mm, dz=2mm Reference Value = 0.352 V/m; Power Drift = 0.12 dB Peak SAR (extrapolated) = 1.65 W/kg SAR(1 g) = 0.387 W/kg; SAR(10 g) = 0.226 W/kg Maximum value of SAR (measured) = 0.536 W/kg 0 dB = 0.536 W/kg = -2.71 dBW/kg Page 4 of 6 FCC ID: 2AW3IP701 Report No.: LCSA07114122EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Date: 2024/8/2 Test Laboratory: LCS-SAR Lab WIFI 5.3G 802.11a 64CH Body Rear 0mm DUT: Smart Diagnostic System; Type: P701; Serial: A240711105-1 Communication System: UID 0, WIFI 5GHz (0); Frequency: 5320 MHz;Duty Cycle: 1:1.058 Medium parameters used: f = 5320 MHz; σ = 4.796 S/m; ε r = 36.215; ρ = 1000 kg/m 3 Phantom section: Flat Section DASY Configuration:  Probe: EX3DV4 - SN3805; ConvF(5.38, 5.38, 5.38); Calibrated: 2023/11/23;  Sensor-Surface: 2mm (Mechanical Surface Detection)  Electronics: DAE3 Sn373; Calibrated: 2024/1/3  Phantom: ELI v5.0; Type: ELI; Serial: 2010  DASY52 52.8.8(1222); SEMCAD X 14.6.10(7331) Configuration/Unnamed procedure/Area Scan (12x15x1): Measurement grid: dx=10mm, dy=10mm Maximum value of SAR (measured) = 0.524 W/kg Configuration/Unnamed procedure/Zoom Scan (7x7x12)/Cube 0: Measurement grid: dx=4mm, dy=4mm, dz=2mm Reference Value = 0.6874 V/m; Power Drift = -0.17 dB Peak SAR (extrapolated) = 1.12 W/kg SAR(1 g) = 0.436 W/kg; SAR(10 g) = 0.177 W/kg Maximum value of SAR (measured) = 0.514 W/kg 0 dB = 0.514 W/kg = -2.89 dBW/kg Page 5 of 6 FCC ID: 2AW3IP701 Report No.: LCSA07114122EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Date: 2024/8/2 Test Laboratory: LCS-SAR Lab WIFI 5.5G 802.11a 116CH Body Rear 0mm DUT: Smart Diagnostic System; Type: P701; Serial: A240711105-1 Communication System: UID 0, WIFI 5GHz (0); Frequency: 5580 MHz;Duty Cycle: 1:1.057 Medium parameters used: f = 5580 MHz; σ = 5.252 S/m; ε r = 35.487; ρ = 1000 kg/m 3 Phantom section: Flat Section DASY Configuration:  Probe: EX3DV4 - SN3805; ConvF(4.75, 4.75, 4.75); Calibrated: 2023/11/23;  Sensor-Surface: 2mm (Mechanical Surface Detection)  Electronics: DAE3 Sn373; Calibrated: 2024/1/3  Phantom: ELI v5.0; Type: ELI; Serial: 2010  DASY52 52.8.8(1222); SEMCAD X 14.6.10(7331) Configuration/Unnamed procedure/Area Scan (12x15x1): Measurement grid: dx=10mm, dy=10mm Maximum value of SAR (measured) = 0.754 W/kg Configuration/Unnamed procedure/Zoom Scan (7x7x12)/Cube 0: Measurement grid: dx=4mm, dy=4mm, dz=2mm Reference Value = 0.9856 V/m; Power …

Text truncated - open the document above for the full version.

RF Exposure Info

Page 1 of 27 FCC ID: 2AW3IP701 Report No.: LCSA07114122EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Appendix C Calibration certificate 1. Dipole D2450V2-SN 808(2023-10-23) D5GHzV2-SN 1046(2023-10-23) 2. DAE DAE3-SN 373(2024-01-03) 3. Probe EX3DV4-SN 3805(2023-11-23) Page 2 of 27 FCC ID: 2AW3IP701 Report No.: LCSA07114122EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Page 3 of 27 FCC ID: 2AW3IP701 Report No.: LCSA07114122EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Page 4 of 27 FCC ID: 2AW3IP701 Report No.: LCSA07114122EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Page 5 of 27 FCC ID: 2AW3IP701 Report No.: LCSA07114122EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Page 6 of 27 FCC ID: 2AW3IP701 Report No.: LCSA07114122EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Page 7 of 27 FCC ID: 2AW3IP701 Report No.: LCSA07114122EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Page 8 of 27 FCC ID: 2AW3IP701 Report No.: LCSA07114122EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Page 9 of 27 FCC ID: 2AW3IP701 Report No.: LCSA07114122EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Page 10 of 27 FCC ID: 2AW3IP701 Report No.: LCSA07114122EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Page 11 of 27 FCC ID: 2AW3IP701 Report No.: LCSA07114122EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Page 12 of 27 FCC ID: 2AW3IP701 Report No.: LCSA07114122EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Page 13 of 27 FCC ID: 2AW3IP701 Report No.: LCSA07114122EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 B…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Darby Tan(Overseas Sales Director)
[email protected]0755-83467556Fax: 0755-83461644

Test Firm

Shenzhen LCS Compliance Testing Laboratory Ltd.Gavin Liang
[email protected]0755-82591330Fax: 0755-82591132

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz1.20 mW
Confidentiality
Long Term
Grant Notes
Output Power listed is peak conducted.

Other Applications from Shenzhen Xtooltech Intelligent Co., Ltd

Smart Diagnostic System - FCC ID 2AW3IF510 - Shenzhen Xtooltech Intelligent Co., Ltd
2AW3IF510

Smart Diagnostic System

Sep 14, 2024

Equipment Class

DTS - Digital Transmission System
Wireless Diagnostics Module,Vehicle Communication Interface - FCC ID 2AW3IV113 - Shenzhen Xtooltech Intelligent Co., Ltd
2AW3IV113

Wireless Diagnostics Module,Vehicle Communication Interface

Sep 02, 2024

Equipment Class

DTS - Digital Transmission System
Smart Diagnostic System - FCC ID 2AW3IP807 - Shenzhen Xtooltech Intelligent Co., Ltd
2AW3IP807

Smart Diagnostic System

Aug 26, 2024

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
Smart Diagnostic System - FCC ID 2AW3IP806 - Shenzhen Xtooltech Intelligent Co., Ltd
2AW3IP806

Smart Diagnostic System

Aug 22, 2024

Equipment Class

DTS - Digital Transmission System
Smart Diagnostic System - FCC ID 2AW3IP902 - Shenzhen Xtooltech Intelligent Co., Ltd
2AW3IP902

Smart Diagnostic System

Dec 14, 2023

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter