FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Shenzhen Xtooltech Intelligent Co., Ltd/
  3. 2AW3IP806

2AW3IP806Smart Diagnostic System

Shenzhen Xtooltech Intelligent Co., Ltd
Smart Diagnostic System - FCC ID 2AW3IP806 - Shenzhen Xtooltech Intelligent Co., Ltd
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Aug 22, 2024
Application Purpose
Original Equipment
Date of Application
Aug 22, 2024
Equipment Note
Smart Diagnostic System
Frequency Range
2412.00000000 - 2462.00000000
Company
Shenzhen Xtooltech Intelligent Co., Ltd
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗
↗
↗
↗
↗
↗

Test Report

↗
↗
↗
↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

User Manual SmartDiagnosticSystem ShenzhenXtooltechIntelligentCo., LTD Note:LE-LAN devices are restricted to indoor operation only in the band 5150-5250 MHz Remarque: les dispositifs LE-LAN ne sont limités au fonctionnement intérieur que dans la bande 5150-5250 mhz HVIN:P806 PleasereadthisusermanualcarefullybeforeusingtheSmartDiagnosticSystem,referredtoasthe “ScanTool”throughoutthisdocument.Whenreadingthemanual,pleasepayattentiontothe words“Note”or“Caution”,andreadthemcarefullyforappropriateoperation. OPERATIONINSTRUCTIONS Forsafeoperation,pleasefollowtheinstructionsbelow:  Keepthedeviceawayfromheatorfumeswheninuse.  Ifthevehiclebatterycontainsacid,pleasekeepyourhandsandskinorfiresourcesaway fromthebatteryduringtesting.  Theexhaustgasofthevehiclecontainsharmfulchemicals.Pleaseensureadequate ventilation.  Donottouchthevehiclecoolingsystemcomponentsorexhaustmanifoldswhentheengineis runningduetothehightemperaturesreached.  Makesurethecarissecurelyparked,NeutralisselectedortheselectorisatthePorN positiontopreventthevehiclefrommovingwhentheenginestarts.  Makesurethe(DLC)DiagnosticLinkConnectorisfunctioningproperlybeforestartingthe testtoavoiddamagetotheDiagnosticComputer.  Donotswitchoffthepowerorunplugtheconnectorsduringtesting.  DoingsomaydamagetheECU(ElectronicControlUnit)and/ortheDiagnosticComputer. CAUTIONS!  Avoidshaking,droppingordismantlingthescantoolasitmaydamagetheinternal components.  UseonlyyourfingertipstotouchtheLCDscreen.Hardorsharpobjectsmaydamagethe scantool.  Donotuseexcessiveforce;  Donotexposethescreentostrongsunlightforalongperiod.  Pleasekeepthescantoolawayfromwaterandmoisture.  StoreandusethescantoolonlywithinthetemperaturerangesidentifiedintheTechnical Specificationssection.  Keeptheunitawayfromstrongmagneticfields. AFTERSALES-SERVICES E-Mail:[email protected] Tel:+8675521670995or+8675586267858(China) OfficialWebsite:www.xtooltech.com Catalogue OperationInstructions ........................................................................................................................1 Cautions! .............................................................................................................................................1 1.GeneralIntroduction .....................................................................................................................3 2.Diagnostics .....................................................................................................................................5 3.SpecialFunctions .........................................................................................................................18 3.2OILRESET ........................................................................................................................21 3.3EPB ....................................................................................................................................23 3.4SAS ....................................................................................................................................25 3.5BMSRESET ......................................................................................................................27 3.5INJECTORCODING ........................................................................................................28 3.7DPFREGENERATION .....................................................................................................31 3.8TPMSRESET ....................................................................................................................34 4.Report ...........................................................................................................................................38 5.Update&FactoryReset ..............................................................................................................4 0 6.RemoteAssistance.....................................................................................................................42 7.Appendix....................................................................................................................................43 8.KeyProgramming.......................................................................................................................44 GeneralIntroduction TheSmartDiagnosticSystemisaprofessionaldevice,basedontheAndroidoperatingsystem.It supportsmulti-languageswitchingandissuitablefordifferentcountriesandregions. TABLET VEHICLECONNECTION PrecautionsforDiagnosis 1.Thevoltagerangeonthecar:+9~+36VDC; 2.Whentestingsomespecialfunctions,theoperatormustoperateaccordingtothe promptsandmeetthetestconditions.Forsomemodels[specialfunctions],the conditionsthatneedtobemetare:enginewatertemperature80°C~105°C,turnoff headlightsandairconditioners,keeptheacceleratorpedalinthereleasedposition, etc.; 3.Theelectroniccontrolsystemsofdifferentmodelsareverycomplicated.Ifyou encountersituationswhereitisimpossibletotestoralargeamountoftestdatais abnormal,youcansearchfortheECUofthevehicleandselectthemenuforthe modelontheECUnameplate; 4.Ifthevehicletypeorelectroniccontrolsystemtobetestedisnotfoundinthe diagnosticfunction,pleaseupgradethevehiclediagnosticsoftwaretothelatest versionusingtheUpdatesmenuorconsulttheXTOOLtechnicalservicedepartment; 5.OnlywiringharnessesprovidedbyXTOOLanddesignedforthedeviceare permittedtobeusedwiththisdevicetoavoiddamagetothevehicleorthedevice; 6.WhenrunningaDiagnosticsfunction,itisforbiddentoshutdownthedevice directly.Youshouldcancelthetaskbeforereturningtothemaininterfaceandthen shuttingdownthedevice. 2.DIAGNOSTICS ThediagnosticfunctioncanreadECUinformation,readandclearDTC(Diagnostic TroubleCodes)andchecklivedataandfreezeframedata.TheDiagnosticapplication canaccesstheECUofvariousvehiclecontrolsystems,includingtheEngine, Transmission,Anti-lockBrakingSystem(ABS),AirbagSafetyRestraingSystem (SRS),ElectronicParkingBrakesystem(EPB)andperformmanytypesofactuation tests. BEGINNINGDIAGNOSTICTESTING Afterthetabletdeviceispr…

Text truncated - open the document above for the full version.

Attestation Statements

Shenzhen Xtooltech Intelligent Co., Ltd Federal Communications Commission Authorization and Evaluation Division Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MD 21046 8/8/2024 U.S. Agent Designation Shenzhen Xtooltech Intelligent Co., Ltd acknowledges their consent for the following contact located in the United States to act as their agent for service of process for the equipment for which authorization is sought (FCC ID: 2AW3IP806): Name and company of U.S. agent: TianHeng Consulting, LLC Physical U.S. address of agent: 30 N Gould St Ste 44116, Sheridan, WY 82801, United States FRN of U.S. agent: 0033401258 Email address of U.S. agent: [email protected] TianHeng Consulting, LLC acknowledges their obligation to accept service of process on behalf of Shenzhen Xtooltech Intelligent Co., Ltd. Shenzhen Xtooltech Intelligent Co., Ltd with the FRN 0029799749 accepts its obligation to maintain an agent for service of process in the United States for no less than one year after either the grantee has permanently terminated all marketing and importation of the applicable equipment within the U.S., or the conclusion of any Commission-related administrative or judicial proceeding involving the equipment, whichever is later. By signing this form, we confirm the above and that we are aware of the application requirements listed under § 2.911(d)(7). The information provided in this letter is based on the referenced rule parts of Title 47 of the CFR as well as KDB 986446 D01. An expiration date for this letter does not exist. In case the U.S. agent changes, the grantee is obligated to notify the FCC within 30 days via the granting TCB. Sincerely, Signature Darby Tan Overseas Sales Director Shenzhen Xtooltech Intelligent Co., Ltd Signature Yingzhi Chen President TianHeng Consulting, LLC 48_[model] US_ Agent_2.911(d)(7) - U, V05

External Photos

Page 1 of 6 FCC ID: 2AW3IP806 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity External Photos of the EUT Fig. 1 Fig. 2 Page 2 of 6 FCC ID: 2AW3IP806 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 3 Fig. 4 Page 3 of 6 FCC ID: 2AW3IP806 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 5 Fig. 6 Page 4 of 6 FCC ID: 2AW3IP806 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 7 Fig. 8 Page 5 of 6 FCC ID: 2AW3IP806 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 9 Fig. 10 Page 6 of 6 FCC ID: 2AW3IP806 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 11

ID Label/Location Info

Page 1 of 1 FCC ID: 2AW3IP806 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Building A and 301 Building C, Juji Industrial Park, Yabianxueziwei Shajing Street, Baoan District, Shenzhen, 518000, P.R.C. Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity LABEL AND LOCATION Material: tagboard Gule: adhesive sticker Font color: black Label color: white & silver polyester (Size: L: 3.0cm x W: 2.5cm) Label Location Smart Diagnostic System Model: P806 FCC ID: 2AW3IP806

Internal Photos

Page 1 of 10 FCC ID: 2AW3IP806 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Internal Photos of the EUT Fig. 1 Fig. 2 BT/WIFI ANT Page 2 of 10 FCC ID: 2AW3IP806 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 3 Fig. 4 Page 3 of 10 FCC ID: 2AW3IP806 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 5 Fig. 6 Page 4 of 10 FCC ID: 2AW3IP806 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 7 Fig. 8 Page 5 of 10 FCC ID: 2AW3IP806 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 9 Fig. 10 Page 6 of 10 FCC ID: 2AW3IP806 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 11 Fig. 12 Page 7 of 10 FCC ID: 2AW3IP806 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 13 Fig. 14 Page 8 of 10 FCC ID: 2AW3IP806 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 15 Fig. 16 Page 9 of 10 FCC ID: 2AW3IP806 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 17 Fig. 18 Page 10 of 10 FCC ID: 2AW3IP806 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 19

RF Exposure Info

Page 1 of 5 FCC ID: 2AW3IP806 Report No.: LCSA06204104EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Appendix A Detailed System Check Results 1. System Performance Check System Performance Check 2450 MHz Head System Performance Check 5250 MHz Head System Performance Check 5600 MHz Head System Performance Check 5750 MHz Head Page 2 of 5 FCC ID: 2AW3IP806 Report No.: LCSA06204104EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Date: 2024/6/24 Test Laboratory: LCS-SAR Lab System Check 2450 MHz DUT: D2450V2; Type: D2450V2; Serial: 808 Communication System: UID 0, CW (0); Frequency: 2450 MHz;Duty Cycle: 1:1 Medium parameters used: f = 2450 MHz; σ = 1.877 S/m; ε r = 39.487; ρ = 1000 kg/m 3 Phantom section: Flat Section DASY Configuration:  Probe: EX3DV4 - SN3805; ConvF(7.42, 7.42, 7.42); Calibrated: 2023/11/23;  Sensor-Surface: 2mm (Mechanical Surface Detection)  Electronics: DAE3 Sn373; Calibrated: 2024/1/3  Phantom: ELI v5.0; Type: ELI; Serial: 2010  DASY52 52.8.8(1222); SEMCAD X 14.6.10(7331) Configuration/Unnamed procedure/Area Scan (4x8x1): Measurement grid: dx=12mm, dy=12mm Maximum value of SAR (measured) = 12.6 W/kg Configuration/Unnamed procedure/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Reference Value = 82.15 V/m; Power Drift = -0.14 dB Peak SAR (extrapolated) = 20.3 W/kg SAR(1 g) = 13.28 W/kg; SAR(10 g) = 5.65 W/kg Maximum value of SAR (measured) = 11.2 W/kg 0 dB = 11.2 W/kg = 10.49 dBW/kg Page 3 of 5 FCC ID: 2AW3IP806 Report No.: LCSA06204104EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Date: 2024/7/4 Test Laboratory: LCS-SAR Lab System Check 5250 MHz DUT: D5GHzV2; Type: D5GHzV2; Serial: 1046 Communication System: UID 0, CW (0); Frequency: 5250 MHz;Duty Cycle: 1:1 Medium parameters used: f = 5250 MHz; σ = 4.622 S/m; ε r = 35.745; ρ = 1000 kg/m 3 Phantom section: Flat Section DASY Configuration:  Probe: EX3DV4 - SN3805; ConvF(5.38, 5.38, 5.38); Calibrated: 2023/11/23;  Sensor-Surface: 2mm (Mechanical Surface Detection)  Electronics: DAE3 Sn373; Calibrated: 2024/1/3  Phantom: ELI v5.0; Type: ELI; Serial: 2010  DASY52 52.8.8(1222); SEMCAD X 14.6.10(7331) Configuration/Unnamed procedure/Area Scan (10x10x1): Measurement grid: dx=10mm, dy=10mm Maximum value of SAR (measured) = 18.3 W/kg Configuration/Unnamed procedure/Zoom Scan (7x7x12)/Cube 0: Measurement grid: dx=4mm, dy=4mm, dz=2mm Reference Value = 42.56 V/m; Power Drift = 0.09 dB Peak SAR (extrapolated) = 23.6 W/kg SAR(1 g) = 7.66 W/kg; SAR(10 g) = 2.36 W/kg Maximum value of SAR (measured) = 19.6 W/kg 0 dB = 19.6 W/kg = 12.92 dBW/kg Page 4 of 5 FCC ID: 2AW3IP806 Report No.: LCSA06204104EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Date: 2024/7/12 Test Laboratory: LCS-SAR Lab System Check 5600MHz DUT: D5GHzV2; Type: D5GHzV2; Serial: 1046 Communication System: UID 0, CW (0); Frequency: 5600 MHz;Duty Cycle: 1:1 Medium parameters used: f = 5600 MHz; σ = 5.124 S/m; ε r = 35.587; ρ = 1000 kg/m 3 Phantom section: Flat Section DASY Configuration:  Probe: EX3DV4 - SN3805; ConvF(4.75, 4.75, 4.75); Calibrated: 2023/11/23;  Sensor-Surface: 2mm (Mechanical Surface Detection)  Electronics: DAE3 Sn373; Calibrated: 2024/1/3  Phantom: ELI v5.0; Type: ELI; Serial: 2010  DASY52 52.8.8(1222); SEMCAD X 14.6.10(7331) Configuration/Unnamed procedure/Area Scan (10x10x1): Measurement grid: dx=10mm, dy=10mm Maximum value of SAR (measured) = 29.6 W/kg Configuration/Unnamed procedure/Zoom Scan (7x7x12)/Cube 0: Measurement grid: dx=4mm, dy=4mm, dz=2mm Reference Value = 60.32 V/m; Power Drift = 0.11 dB Peak SAR (extrapolated) = 32.6 W/kg SAR(1 g) = 8.19 W/kg; SAR(10 g) = 2.48 W/kg Maximum value of SAR (measured) = 26.6 W/kg 0 dB = 26.6 W/kg = 14.25 dBW/kg Page 5 of 5 FCC ID: 2AW3IP806 Report No.: LCSA06204104EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Date: 2024/7/12 Test Laboratory: LCS-SAR Lab System Check 5750 MHz DUT: D5GHzV2; Type: D5GHzV2; Serial: 1046 Communication System: UID 0, CW (0); Frequency: 5750 MHz;Duty Cycle: 1:1 Medium parameters used: f = 5750 MHz; σ = 5.365 S/m; ε r = 35.687; ρ = 1000 kg/m 3 Phantom section: Flat Section DASY Configuration:  Probe: EX3DV4 - SN3805; ConvF(4.88, 4.88, 4.88); Calibrated: 2023/11/23;  Sensor-Surface: 2mm (Mechanical Surface Detection)  Electronics: DAE3 Sn373; Calibrated: 2024/1/3  Phantom: ELI v5.0; Type: ELI; Serial: 2010  DASY52 52.8.8(1222); SEMCAD X 14.6.10(7331) Configuration/Unnamed procedure/Area Scan (10x10x1): Measurement grid: dx=10mm, dy=10mm Maximum value of SAR (measured) = 16.3 W/kg Configuration/Unnamed procedure/Zoom Scan (7x7x12)/Cube 0: Measurement grid: dx=4mm, dy=4mm, dz=2mm Reference Value = 44.65 V/m; Power Drift = 0.13 dB Peak SAR (extrapolated) = 23.5 W/kg SAR(1 g) = 7.69 W/kg; SAR(10 g) = 2.35 W/kg Maximum value of SAR (measured) = 18…

Text truncated - open the document above for the full version.

RF Exposure Info

Page 1 of 6 FCC ID: 2AW3IP806 Report No.: LCSA06204104EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Appendix B Detailed Test Results 1. WIFI WIFI 2.4GHz for Body WIFI 5.2GHz for Body WIFI 5.3GHz for Body WIFI 5.5GHz for Body WIFI 5.8GHz for Body Page 2 of 6 FCC ID: 2AW3IP806 Report No.: LCSA06204104EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Date: 2024/6/24 Test Laboratory: LCS-SAR Lab WIFI 2.4G 802.11b 1CH Rear side 0mm DUT: Smart Diagnostic System; Type: P806; Serial: A240620001-1 Communication System: UID 0, WIFI 2.4GHz (0); Frequency: 2412 MHz;Duty Cycle: 1:1.008 Medium parameters used: f = 2412 MHz; σ = 1.811 S/m; ε r = 39.282; ρ = 1000 kg/m 3 Phantom section: Flat Section DASY Configuration:  Probe: EX3DV4 - SN3805; ConvF(7.42, 7.42, 7.42); Calibrated: 2023/11/23;  Sensor-Surface: 2mm (Mechanical Surface Detection)  Electronics: DAE3 Sn373; Calibrated: 2024/1/3  Phantom: ELI v5.0; Type: ELI; Serial: 2010  DASY52 52.8.8(1222); SEMCAD X 14.6.10(7331) Configuration/Unnamed procedure/Area Scan (11x13x1): Measurement grid: dx=12mm, dy=12mm Maximum value of SAR (measured) = 0.663 W/kg Configuration/Unnamed procedure/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Reference Value = 5.114 V/m; Power Drift = 0.03 dB Peak SAR (extrapolated) = 1.14 W/kg SAR(1 g) = 0.524 W/kg; SAR(10 g) = 0.322 W/kg Maximum value of SAR (measured) = 0.676 W/kg Page 3 of 6 FCC ID: 2AW3IP806 Report No.: LCSA06204104EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Date: 2024/7/4 Test Laboratory: LCS-SAR Lab WIFI 5.2G 802.11a 40CH Body Rear 0mm DUT: Smart Diagnostic System; Type: P806; Serial: A240620001-1 Communication System: UID 0, WIFI 5GHz (0); Frequency: 5200 MHz;Duty Cycle: 1:1.058 Medium parameters used: f = 5200 MHz; σ = 4.666 S/m; ε r = 35.974; ρ = 1000 kg/m 3 Phantom section: Flat Section DASY Configuration:  Probe: EX3DV4 - SN3805; ConvF(5.38, 5.38, 5.38); Calibrated: 2023/11/23;  Sensor-Surface: 2mm (Mechanical Surface Detection)  Electronics: DAE3 Sn373; Calibrated: 2024/1/3  Phantom: ELI v5.0; Type: ELI; Serial: 2010  DASY52 52.8.8(1222); SEMCAD X 14.6.10(7331) Configuration/Unnamed procedure/Area Scan (12x15x1): Measurement grid: dx=10mm, dy=10mm Maximum value of SAR (measured) = 0.421 W/kg Configuration/Unnamed procedure/Zoom Scan (7x7x12)/Cube 0: Measurement grid: dx=4mm, dy=4mm, dz=2mm Reference Value = 0.1254 V/m; Power Drift = -0.16 dB Peak SAR (extrapolated) = 1.54 W/kg SAR(1 g) = 0.433 W/kg; SAR(10 g) = 0.196 W/kg Maximum value of SAR (measured) = 0.434 W/kg Page 4 of 6 FCC ID: 2AW3IP806 Report No.: LCSA06204104EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Date: 2024/7/4 Test Laboratory: LCS-SAR Lab WIFI 5.3G 802.11a 52CH Body Rear 0mm DUT: Smart Diagnostic System; Type: P806; Serial: A240620001-1 Communication System: UID 0, WIFI 5GHz (0); Frequency: 5260 MHz;Duty Cycle: 1:1.058 Medium parameters used: f = 5260 MHz; σ = 4.661 S/m; ε r = 36.197; ρ = 1000 kg/m 3 Phantom section: Flat Section DASY Configuration:  Probe: EX3DV4 - SN3805; ConvF(5.38, 5.38, 5.38); Calibrated: 2023/11/23;  Sensor-Surface: 2mm (Mechanical Surface Detection)  Electronics: DAE3 Sn373; Calibrated: 2024/1/3  Phantom: ELI v5.0; Type: ELI; Serial: 2010  DASY52 52.8.8(1222); SEMCAD X 14.6.10(7331) Configuration/Unnamed procedure/Area Scan (12x15x1): Measurement grid: dx=10mm, dy=10mm Maximum value of SAR (measured) = 0.365 W/kg Configuration/Unnamed procedure/Zoom Scan (7x7x12)/Cube 0: Measurement grid: dx=4mm, dy=4mm, dz=2mm Reference Value = 0.3754 V/m; Power Drift = 0.03 dB Peak SAR (extrapolated) = 1.74 W/kg SAR(1 g) = 0.466 W/kg; SAR(10 g) = 0.123 W/kg Maximum value of SAR (measured) = 0.349 W/kg Page 5 of 6 FCC ID: 2AW3IP806 Report No.: LCSA06204104EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Date: 2024/7/12 Test Laboratory: LCS-SAR Lab WIFI 5.5G 802.11a 100CH Body Rear 0mm DUT: Smart Diagnostic System; Type: P806; Serial: A240620001-1 Communication System: UID 0, WIFI 5GHz (0); Frequency: 5500 MHz;Duty Cycle: 1:1.057 Medium parameters used: f = 5500 MHz; σ = 4.977 S/m; ε r = 35.287; ρ = 1000 kg/m 3 Phantom section: Flat Section DASY Configuration:  Probe: EX3DV4 - SN3805; ConvF(4.75, 4.75, 4.75); Calibrated: 2023/11/23;  Sensor-Surface: 2mm (Mechanical Surface Detection)  Electronics: DAE3 Sn373; Calibrated: 2024/1/3  Phantom: ELI v5.0; Type: ELI; Serial: 2010  DASY52 52.8.8(1222); SEMCAD X 14.6.10(7331) Configuration/Unnamed procedure/Area Scan (12x15x1): Measurement grid: dx=10mm, dy=10mm Maximum value of SAR (measured) = 0.412W/kg Configuration/Unnamed procedure/Zoom Scan (7x7x12)/Cube 0: Measurement grid: dx=4mm, dy=4mm, dz=2mm Reference Value = 0.6524 V/m; Power Drift = 0.03 dB Peak SAR (extrapolated) = 1.01 W/kg SAR(1 g) = 0.468 W/kg; SAR(10 g) = 0.225 W/kg Ma…

Text truncated - open the document above for the full version.

RF Exposure Info

Page 1 of 27 FCC ID: 2AW3IP806 Report No.: LCSA06204104EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Appendix C Calibration certificate 1. Dipole D2450V2-SN 808(2023-10-23) D5GHzV2-SN 1046(2023-10-23) 2. DAE DAE3-SN 373(2024-01-03) 3. Probe EX3DV4-SN 3805(2023-11-23) Page 2 of 27 FCC ID: 2AW3IP806 Report No.: LCSA06204104EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Page 3 of 27 FCC ID: 2AW3IP806 Report No.: LCSA06204104EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Page 4 of 27 FCC ID: 2AW3IP806 Report No.: LCSA06204104EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Page 5 of 27 FCC ID: 2AW3IP806 Report No.: LCSA06204104EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Page 6 of 27 FCC ID: 2AW3IP806 Report No.: LCSA06204104EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Page 7 of 27 FCC ID: 2AW3IP806 Report No.: LCSA06204104EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Page 8 of 27 FCC ID: 2AW3IP806 Report No.: LCSA06204104EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Page 9 of 27 FCC ID: 2AW3IP806 Report No.: LCSA06204104EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Page 10 of 27 FCC ID: 2AW3IP806 Report No.: LCSA06204104EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Page 11 of 27 FCC ID: 2AW3IP806 Report No.: LCSA06204104EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Page 12 of 27 FCC ID: 2AW3IP806 Report No.: LCSA06204104EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabia…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Darby Tan(Overseas Sales Director)
[email protected]0755-83467556Fax: 0755-83461644

Test Firm

Shenzhen LCS Compliance Testing Laboratory Ltd.Gavin Liang
[email protected]0755-82591330Fax: 0755-82591132

Technical Specifications

#Rule PartsFrequency RangePower Output
215C2.41 GHz - 2.46 GHz36.10 mW
Confidentiality
Long Term
Grant Notes
Output Power listed is peak conducted. This device supports 802.11b, 802.11g and 802.11n with a 20 MHz and 40 MHz bandwidth mode. For body worn operation, this Smart Diagnostic System has been tested and meets FCC RF exposure guidelines when used with an accessory that contains no metal and that positions the Smart Diagnostic System a minimum of 0 mm from the body. Use of other accessories may not ensure compliance with FCC RF exposure guidelines. End users must be informed of the body worn requirements for satisfying RF Exposure compliance. The highest reported SAR for body-worn accessory transmission use conditions is 0.58 W/kg.

Other Applications from Shenzhen Xtooltech Intelligent Co., Ltd

Smart Diagnostic System - FCC ID 2AW3IF510 - Shenzhen Xtooltech Intelligent Co., Ltd
2AW3IF510

Smart Diagnostic System

Sep 14, 2024

Equipment Class

DTS - Digital Transmission System
Wireless Diagnostics Module,Vehicle Communication Interface - FCC ID 2AW3IV113 - Shenzhen Xtooltech Intelligent Co., Ltd
2AW3IV113

Wireless Diagnostics Module,Vehicle Communication Interface

Sep 02, 2024

Equipment Class

DTS - Digital Transmission System
Smart Diagnostic System - FCC ID 2AW3IP807 - Shenzhen Xtooltech Intelligent Co., Ltd
2AW3IP807

Smart Diagnostic System

Aug 26, 2024

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
Smart Diagnostic System - FCC ID 2AW3IP701 - Shenzhen Xtooltech Intelligent Co., Ltd
2AW3IP701

Smart Diagnostic System

Aug 22, 2024

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
Smart Diagnostic System - FCC ID 2AW3IP902 - Shenzhen Xtooltech Intelligent Co., Ltd
2AW3IP902

Smart Diagnostic System

Dec 14, 2023

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter