Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
ShenzhenSDMCTechnologyCo.,Ltd. CoveredEquipmentCertificationAttestationLetter 8/10/2026 NemkoNorthAmerica,Inc. 303RiverRoad Ottawa K1V1H2 Canada ATTN.:ReviewingEngineer FCCID:2AW68-B082N03F7 ShenzhenSDMCTechnologyCo.,Ltd.(“theapplicant”) certifiesthattheequipmentfor whichauthorizationissoughtisnot“covered” equipmentprohibitedfromreceivingan equipmentauthorizationpursuanttosection2.903oftheFCCrules.Thisincludes certifyingthattheequipmentforwhichauthorizationissoughtdoesnotinclude cybersecurityoranti-virussoftwareproducedorprovidedbyKasperskyLab,Inc.orany ofitssuccessorsandassignees,includingequipmentwithintegratedKasperskyLab,Inc. (oranyofitssuccessorsandassignees)cybersecurityoranti-virussoftwarepursuantto DA-24-886andKDB986446D01CoveredEquipmentGuidancesectionB(2a). Note:Iftheequipmentforwhichtheapplicantseeksauthorizationisproducedby anyoftheentitiesidentifiedonthecurrentCoveredList , theapplicantshould includeanexplanationonwhytheequipmentisnot“covered” equipment. ShenzhenSDMCTechnologyCo.,Ltd.(“theapplicant”) certifiesthat,asofthedateof thefilingoftheapplication,theapplicant isnotidentifiedontheCoveredListasan entityproducing“covered”equipment. Signed: Printedname:RyanYan Title:Manager CompanyName:ShenzhenSDMCTechnologyCo.,Ltd. Date:8/10/2026
Shenzhen SDMC Technology Co.,Ltd. * the applicant must designate a contact located in the United States for purposes of acting as the applicant’s agent for service of process, regardless of whether the applicant is a domestic or foreign entity. An applicant located in the United States may designate itself as the agent for service of process. U.S. Agent Designation for Service of Process - Certification Attestation Letter August 6, 2026 Nemko North America, Inc. 303 River Road Ottawa K1V 1H2 Canada ATTN.: Reviewing Engineer FCC ID: 2AW68-B082N03F7 Per section 2.911(d)(7) of the FCC rules, Company Name: WeFa Selection Trade Technology Co., LTD Physical U.S. Company Address: 30 N. GOULD ST . ST E N SHERIDAN WY,SHERIDAN, WY 82801,United States Agent name: WeFa Selection Trade Technology Co., LTD Agent Email Address: [email protected] FRN: 0033767856 The above contact person accepts the obligation for service of process. The applicant accepts to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any Commission-related proceeding involving the equipment. Applicant Signed: Designated Agent Signed: (Required, if different to Applicant): Signed: Signed: Printed name: Ryan Yan Printed name: Joson Ye Title: Manager Title: Manager Company Name: Shenzhen SDMC Technology Co.,Ltd. Company Name: WeFa Selection Trade Technology Co., LTD Date: August 6, 2026 Date: July 31, 2026 FRN Code: 0029837143 FRN Code: 0033767856 equipment for which authorization is sought is designated to the following U.S. Designated agent* for service of process: Shenzhen SDMC Technology Co.,Ltd. certifies that the
Family Certification Attestation Letter 8/6/2026 Nemko Canada Inc 303 River Road Ottawa K1V 1H2 Canada Company Name: ShenzhenSDMC Technology Co.,Ltd. FCC ID: 2AW68-B082N03F7 Models: B082-02-F7, B082-01-F7, B082N-03-F7, B082N-04-F7, B082BQ-02- F7,B082BQ-01-F7, B082-XX-ZY, B082Z-XX-ZY, B082ZZ-XX-ZY (XX=01-99,Z=A~Z, Y=1-9) We hereby request Family Certification for the above mentioned Models based on them being electrically identical. Above models are identical in schematic and structure, only the model name, appearance and button silk-screening are different, therefore the test performed on the model __B082-02-F7_. Signed: Printed name:Ryan Yan Title:N/A Date:8/6/2026
Shenzhen SDMC Technology Co.,Ltd. August 11, 2026 Nemko North America, Inc. 303 River Road Ottawa, Ontario, Canada K1V 1H2 REQUEST FOR CONFIDENTIALITY - FCC FCC ID:2AW68-B082N03F7 Pursuant to Sections 0.457(d) and 0.459 of the Commission’s Rules and FCC Guidance document 726920, we hereby request permanent confidential treatment of exhibits identified as such in the table below and request they are permanently withheld from public review based on the documents containing trade secrets and proprietary information not customarily released to the public. The public disclosure of this information might be harmful to the applicant and provide unjustified benefits to its competitors. We also request short-term confidentiality on certain exhibits until the intended date of marketing as outlined below. We request the exhibits be withheld from public view for a period of 180 days. We attest marketing of the product will only commence after the period of short-term confidentiality expires, or if marketing is to commence before the requested number of days listed above, the grantee will inform Nemko to release the Short-Term Confidentiality information withheld on the FCC equipment authorization website. Exhibit Type of Confidentiality Requested Block Diagrams ☒ Permanent ☐ Short Term External Photos ------------------ ☒ Short Term Internal Photos ☐ Permanent* ☒ Short Term Operation Description ☒ Permanent ☐ Short Term Parts List & Placement/BOM ☐ Permanent ☐ Short Term Tune-Up Procedure ☐ Permanent ☐ Short Term Schematic Diagrams ☒ Permanent ☐ Short Term Test Setup Photos ------------------ ☒ Short Term User’s Manual ☐ Permanent* ☒ Short Term The asterisked items (*) require further information to be provided in this justification letter before permanent confidentiality will be extended to these exhibits. Please refer to FCC KDB 726920 D01 found at: https://apps.fcc.gov/oetcf/kdb/forms/FTSSearchResultPage.cfm?switch=P&id=41731 and review section II, 3) regarding specific information that must accompany these requests. Note: any documents held under the Short-Term confidentiality will automatically become public after the requested time if an appropriate extension request has not been received. Any exhibits (i.e., schematic diagrams) that may have already been requested to have “Permanent” confidentiality as shown above need not be repeated under Short-Term confidentiality request. Sincerely, Signed: Printed name: Ryan Yan Title: Manager Company Name: Shenzhen SDMC Technology Co.,Ltd.
HY- FCC 2.1093 Ver.1.1 Page 1 of 5 Report No.: RF260509004-03-002 FCC RF EXPOSURE REPORT FCC ID: 2AW68-B082N03F7 Test Report No...........: RF260509004-03-002 Product(s) Name.........: Remote Control Model(s)....................: B082-02-F7, B082-01-F7, B082N-03-F7, B082N-04-F7, B082BQ-02-F7, B082BQ-01-F7, B082-XX-ZY, B082Z-XX-ZY, B082ZZ-XX-ZY (XX=01-99, Z=A~Z, Y=1-9) Trade Mark................: N/A Applicant...................: Shenzhen SDMC Technology Co.,Ltd. Address....................: Floor 1, Building 5, Hengtongfa Industrial Zone, Tangtou Industrial Park, Tangtou Community, Shiyan Street, Baoan District, Shenzhen, China Receipt Date..............: 2026.06.04 Test Date...................: 2026.06.08 ~ 2026.06.17 Issued Date................: 2026.06.18 Standards..................: CFR47 FCC Part 1: Section 1.1310; CFR47 FCC Part 2: Section 2.1093; FCC KDB Publication 447498 D04; FCC KDB Publication 865664 D02 v01r02 Testing Laboratory......: Shenzhen Haiyun Standard Technical Co., Ltd. Prepared By: Checked By: Approved By: Jason Huang Black Ding Tim Zhang HY-FCC 2.1093 Ver.1.1 Page 2 of 5 Report No.: RF260509004-03-002 History of this test report Original Report Issue Date: 2026.06.18 ● No additional attachment ○ Additional attachments were issued following record Attachment No. Issue Date Description HY-FCC 2.1093 Ver.1.1 Page 3 of 5 Report No.: RF260509004-03-002 1. MPE CALCULATION METHOD Limit Calculation Method ERP/EIRP = P T +G T −L C ERP/EIRP is the equivalent (or effective) radiated power [in same units as P T , typically dBW, dBm, or power spectral density (psd)], relative to either a dipole antenna (ERP) or an isotropic antenna (EIRP). P T is the transmitter output power, in dBW, dBm, or psd (power over a specified reference bandwidth). G T is the gain of the transmitting antenna, in dBd (ERP) or dBi (EIRP). L C is the signal attenuation in the connecting cable between the transmitter and the antenna, in dB. Table for Filed Antenna For BLE Antenna gain Antenna Type 0.1dBi PCB antenna HY-FCC 2.1093 Ver.1.1 Page 4 of 5 Report No.: RF260509004-03-002 2. TEST RESULTS Worst case as below Mode Output power to antenna (dBm) Ant gain (dBi) EIRP (dBm) ERP (dBm) ERP(mw) Distance (cm) Pth (mW) BLE 3.00 0.1 3.10 0.95 1.24 0.5 2.79 Note: 1. ERP = EIRP −2.15 dB 2. 1.24mW<2.79mw Conclusion The SAR evaluation is not required HY-FCC 2.1093 Ver.1.1 Page 5 of 5 Report No.: RF260509004-03-002 Statement 1. The report is invalid without the official seal or special seal of Shenzhen Haiyun Standard Technical Co., Ltd. (hereinafter referred to as the unit). 2. The report is invalid without the signature of the approver. 3. The report is invalid if altered arbitrarily. 4. The report shall not be partially copied without the written approval of the unit. 5. The reported test results are only valid for the tested samples. 6. If there is any objection to the test report, it shall be submitted to the test unit within 15 days from the date of receiving the report, and the overdue shall not be accepted. Shenzhen Haiyun Standard Technical Co., Ltd. Address: Room 110, 111, 112, 113, 115, 116, Block B, Jinyuan Business Building, No. 302, Xixiang Avenue, Labor Community, Xixiang Street, Baoan District, Shenzhen, China (END OF REPORT)
NOTE:ThisdocumentisissuedbyShenzhenMorlabCommunicationsTechnologyCo.,Ltd.,thetestreportshallnotbereproducedexceptin fullwithoutpriorwrittenpermissionofthecompany.Thetestresultsapplyonlytotheparticularsample(s)testedandtothespecifictestscarried outwhichisavailableonrequestforvalidationandinformationconfirmedatourwebsite. MORLAB ShenzhenMorlabCommunicationsTechnologyCo.,Ltd.,FL.1-3,BuildingA, FeiYangSciencePark,No.8LongChangRoad,Block67,BaoAnDistrict, ShenZhen,GuangDongProvince,P.R.China Tel:86-755-36698555Fax:86-755-36698525 Http://www.morlab.cnE-mail:[email protected] Page1of 13 REPORTNo.:SZ25030229E01 TESTREPORT APPLICANT: ShenzhenC&DElectronicsCo.,Ltd. PRODUCTNAME: remotecontrol MODELNAME:RF622A TRADENAME: N/A BRANDNAME:N/A STANDARD(S):IEEEStd149-2021 RECEIPTDATE: 2025-03-17 TESTDATE: 2025-03-17 ISSUEDATE: 2025-03-18 Editedby: : GuoPenghua(Rapporteur) Approvedby: : ChiShide(Supervisor) Testedby MORLAB ShenzhenMorlabCommunicationsTechnologyCo.,Ltd.,FL.1-3,BuildingA, FeiYangSciencePark,No.8LongChangRoad,Block67,BaoAnDistrict, ShenZhen,GuangDongProvince,P.R.China Tel:86-755-36698555Fax:86-755-36698525 Http://www.morlab.cnE-mail:[email protected] Page2of13 REPORTNo.:SZ25030229E01 DIRECTORY 1.TechnicalInformation ........................................................................................................3 1.1.ApplicantandManufacturerInformation ....................................................................3 1.2.EquipmentUnderTest(EUT)Description...................................................................3 2.TestResults........................................................................................................................4 2.1.AppliedReferenceDocuments.....................................................................................4 2.2.TestConditions...............................................................................................................4 2.3.MeasurementUncertainty.............................................................................................4 2.4.TestResultslists.............................................................................................................5 AnnexATestSetupPhotos..................................................................................................6 AnnexBFigures .....................................................................................................................7 1.2DRadiationPattern .........................................................................................................7 2.3DRadiationPattern .........................................................................................................8 AnnexCEUTPhotos ...........................................................................................................10 AnnexDGeneralInformation .............................................................................................13 1.1IdentificationoftheResponsibleTestingLaboratory..............................................13 1.2IdentificationoftheResponsibleTestingLocation..................................................13 1.3TestEquipmentsUtilized..............................................................................................13 1.4TestSoftwareUtilized....................................................................................................13 ChangeHistory VersionDateReasonforchange 1.02025-03-18Firstedition MORLAB ShenzhenMorlabCommunicationsTechnologyCo.,Ltd.,FL.1-3,BuildingA, FeiYangSciencePark,No.8LongChangRoad,Block67,BaoAnDistrict, ShenZhen,GuangDongProvince,P.R.China Tel:86-755-36698555Fax:86-755-36698525 Http://www.morlab.cnE-mail:[email protected] Page3of13 REPORTNo.:SZ25030229E01 1.TechnicalInformation Note:Providebyapplicant. 1.1.ApplicantandManufacturerInformation Applicant:ShenzhenC&DElectronicsCo.,Ltd. ApplicantAddress:10/F,Unit1,BlockA,Building1,BaonengS&TPark, QingxiangRd.,Longhua,Shenzhen518110,China Manufacturer:ShenzhenC&DElectronicsCo.,Ltd. ManufacturerAddress:10/F,Unit1,BlockA,Building1,BaonengS&TPark, QingxiangRd.,Longhua,Shenzhen518110,China 1.2.EquipmentUnderTest(EUT)Description WirelessTypeN/A Testfrequencyband2400MHz-2500MHz BrandnameN/A HardwareVersionN/A SoftwareVersionN/A IMEIN/A Samplenumber1# MORLAB ShenzhenMorlabCommunicationsTechnologyCo.,Ltd.,FL.1-3,BuildingA, FeiYangSciencePark,No.8LongChangRoad,Block67,BaoAnDistrict, ShenZhen,GuangDongProvince,P.R.China Tel:86-755-36698555Fax:86-755-36698525 Http://www.morlab.cnE-mail:[email protected] Page4of13 REPORTNo.:SZ25030229E01 2.TestResults 2.1.AppliedReferenceDocuments Leadingreferencedocumentsfortesting: No.IdentityDocumentTitle 1 IEEEStd149-2021 IEEERecommendedPracticeforAntenna Measurements 2.2.TestConditions TestEnvironmentConditions : RelativeHumidity(%):25-75 Temperature(°C):10-30 2.3.MeasurementUncertainty Theuncertaintyiscalculatedusingthemethodssuggestedinthe"GuidetotheExpressionof UncertaintyinMeasurement"(GUM)publishedbyISO.Whenthetestresultisacriticalvalue,we willusethemeasurementuncertaintygivethejudgmentresultbasedonthe95%Confidence intervals. MORLAB ShenzhenMorlabCommunicationsTechnologyCo.,Ltd.,FL.1-3,BuildingA, FeiYangSciencePark,No.8LongChangRoad,Block67,BaoAnDistrict, ShenZhen,GuangDongProvince,P.R.China Tel:86-755-36698555Fax:86-755-36698525 Http://www.morlab.cnE-mail:[email protected] Page5of13 REPORTNo.:SZ25030229E01 2.4.TestResultslists 2.4.1. Gain FrequencyGain(dBi) 2400MHz0.08 2410MHz-0.09 2420MHz0.10 2430MHz0.07 2440MHz0.03 2450MHz-0.23 2460MHz-0.47 2470MHz-0.66 2480MHz-0.89 2490MHz-1.01 2500MHz-1.31 MORLAB ShenzhenMorlabCommunicationsTechnologyCo.,Ltd.,FL.1-3,BuildingA, FeiYangSciencePark,No.8LongChangRoad,Block67,BaoAnDistrict, ShenZhen,GuangDongProvince,P.R.China Tel:86-755-36698555Fax:86-755-36698525 Http://www.morlab.cnE-mail:[email protected] Page6of13 REPORTNo.:SZ25030229E01 AnnexATestSetupPhotos MORLAB ShenzhenMorlabCommunicationsTechnologyCo.,Ltd.,FL.1-3,BuildingA, FeiYangSciencePark,No.…
Text truncated - open the document above for the full version.
HY-FCC part 15C-BLE Ver.1.1Page 1 of 62Report No.: RF260509004-03-001 RF TEST REPORT FCC ID: 2A W68-B082N03F7 Test Report No...........: RF260509004-03-001 Product(s) Name.........: Remote Control Model(s)....................: B082-02-F7, B082-01-F7, B082N-03-F7, B082N-04-F7, B082BQ-02-F7, B082BQ-01-F7, B082-XX-ZY, B082Z-XX-ZY, B082ZZ-XX-ZY(XX=01-99, Z=A~Z, Y=1-9) Trade Mark................: N/A Applicant...................: Shenzhen SDMC Technology Co.,Ltd. Address....................: Floor 1, Building 5, Hengtongfa Industrial Zone, Tangtou Industrial Park, Tangtou Community, Shiyan Street, Baoan District, Shenzhen, China Receipt Date..............: 2026.06.04 Test Date...................: 2026.06.08 ~ 2026.06.17 Issued Date................: 2026.06.18 Standards..................: 47 CFR FCC Part 15, Subpart C(Section 15.247) ANSI C63.10-2020+Cor. 1-2023 Testing Laboratory......: Shenzhen Haiyun Standard Technical Co., Ltd. Prepared By: Checked By: Approved By: Lemon He Black Ding Tim Zhang HY-FCC part 15C-BLE Ver.1.1 Page 2 of 62 Report No.: RF260509004-03-001 Table of Contents REPORT ISSUED HISTORY 4 1 . SUMMARY OF TEST RESULTS 5 1.1 TEST FACILITY 6 1.2 MEASUREMENT UNCERTAINTY 6 1.3 TEST ENVIRONMENT CONDITIONS 6 2 . GENERAL INFORMATION 7 2.1 GENERAL DESCRIPTION OF EUT 7 2.2 DESCRIPTION OF TEST MODES 8 2.3 PARAMETERS OF TEST SOFTWARE 8 2.4 SUPPORT UNITS 8 3 . AC POWER LINE CONDUCTED EMISSIONS 9 3.1 LIMIT 9 3.2 TEST PROCEDURE 9 3.3 DEVIATION FROM TEST STANDARD 9 3.4 TEST SETUP 10 3.5 EUT OPERATING CONDITIONS 10 3.6 TEST RESULTS 10 4 . RADIATED EMISSIONS 11 4.1 LIMIT 11 4.2 TEST PROCEDURE 12 4.3 DEVIATION FROM TEST STANDARD 13 4.4 TEST SETUP 13 4.5 EUT OPERATING CONDITIONS 14 4.6 TEST RESULT - 9 KHZ TO 30 MHZ 14 4.7 TEST RESULT - 30 MHZ TO 1000 MHZ 14 4.8 TEST RESULT - ABOVE 1000 MHZ 14 5 . BANDWIDTH 15 5.1 LIMIT 15 5.2 TEST PROCEDURE 15 5.3 DEVIATION FROM STANDARD 15 5.4 TEST SETUP 15 5.5 EUT OPERATION CONDITIONS 15 5.6 TEST RESULTS 15 6 . MAXIMUM OUTPUT POWER 16 6.1 LIMIT 16 6.2 TEST PROCEDURE 16 HY-FCC part 15C-BLE Ver.1.1 Page 3 of 62 Report No.: RF260509004-03-001 6.3 DEVIATION FROM STANDARD 16 6.4 TEST SETUP 16 6.5 EUT OPERATION CONDITIONS 16 6.6 TEST RESULTS 16 7 . CONDUCTED SPURIOUS EMISSION 17 7.1 LIMIT 17 7.2 TEST PROCEDURE 17 7.3 DEVIATION FROM STANDARD 17 7.4 TEST SETUP 17 7.5 EUT OPERATION CONDITIONS 17 7.6 TEST RESULTS 17 8 . POWER SPECTRAL DENSITY 18 8.1 LIMIT 18 8.2 TEST PROCEDURE 18 8.3 DEVIATION FROM STANDARD 18 8.4 TEST SETUP 18 8.5 EUT OPERATION CONDITIONS 18 8.6 TEST RESULTS 18 9 . MEASUREMENT INSTRUMENTS LIST 19 10 . ANTENNA REQUIREMENT 20 APPENDIX B - RADIATED EMISSION - 9 KHZ TO 30 MHZ 21 APPENDIX C - RADIATED EMISSION - 30 MHZ TO 1000 MHZ 22 APPENDIX D - RADIATED EMISSION - ABOVE 1000 MHZ 25 APPENDIX E - BANDWIDTH 31 APPENDIX F - MAXIMUM OUTPUT POWER 40 APPENDIX G - CONDUCTED SPURIOUS EMISSION 45 APPENDIX H - POWER SPECTRAL DENSITY 57 HY-FCC part 15C-BLE Ver.1.1 Page 4 of 62 Report No.: RF260509004-03-001 REPORT ISSUED HISTORY Original Report Issue Date: 2026.06.18 ● No additional attachment ○ Additional attachments were issued following record Attachment No. Issue Date Description HY-FCC part 15C-BLE Ver.1.1 Page 5 of 62 Report No.: RF260509004-03-001 1. SUMMARY OF TEST RESULTS Test procedures according to the technical standard(s): FCC CFR Title 47, Part 15, Subpart C Standard(s) Section Test Item Test Result Judgment Remark 15.207 AC Power Line Conducted Emissions ------ ------ N/A 15.247(d) 15.205(a) 15.209(a) Radiated Emissions APPENDIX B APPENDIX C APPENDIX D PASS ------ 15.247(a)(2) Bandwidth APPENDIX E PASS ------ 15.247(b)(3) Maximum Output Power APPENDIX F PASS ------ 15.247(d) Conducted Spurious Emission APPENDIX G PASS ------ 15.247(e) Power Spectral Density APPENDIX H PASS ------ 15.203 Antenna Requirement ------ PASS Note(2) Note: (1) “N/A” denotes test is not applicable to this device. (2) The device what use a permanently attached antenna were considered sufficient to comply with the provisions of 15.203. HY-FCC part 15C-BLE Ver.1.1 Page 6 of 62 Report No.: RF260509004-03-001 1.1 TEST FACILITY Company: Shenzhen Haiyun Standard Technical Co., Ltd. Address: No. 110-113, 115, 116, Block B, Jinyuan Business Building, Bao'an District, Shenzhen, China CNAS Registration Number: CNAS L18252 FCC Designation Number CN1340 CAB identifier CN0145 A2LA Certificate Number 6823.01 1.2 MEASUREMENT UNCERTAINTY ISO/IEC 17025 requires that an estimate of the measurement uncertainties associated with the emissions test results be included in the report. The measurement uncertainties given below are based on a 95% confidence level (based on a coverage factor (k=2)) Uncertainty Parameter Uncertainty Occupied Channel Bandwidth ±102kHz RF power conducted ±0.243dB Power Spectral Density ±0.743dB Conducted Spurious Emission ±1.328dB Conducted emission(9kHz~30MHz) AC main ±2.68dB Radiated emission(9kHz~30MHz) ±3.50dB Radiated emission (30MHz~1GHz) ±4.20dB Radiated emission (1GHz~18GHz) ±5.10dB Radiated emission (18GHz~40GHz) ±5.26dB Note: Unless specifically mentioned, the uncertainty of measurement has not been taken into account to declare the compliance or non-compliance to the specification. 1.3 TEST ENVIRONMENT CONDITIONS Test Item Temperature Humidity Test Voltage Tested By Radiated Emissions-9 kHz to 30 MHz 23.8°C 52% DC 3V Lemon He Radiated Emissions-30 MHz to 1000 MHz 23.8°C 52% DC 3V Lemon He Radiated Emissions-Above 1000 MHz 23.8°C 52% DC 3V Lemon He Bandwidth 23.3°C 49% DC 3V Elio Lin Maximum Output Power 23.3°C 49% DC 3V Elio Lin Conducted Spurious Emission 23.3°C 49% DC 3V Elio Lin Power Spectral Density 23.3°C 49% DC 3V Elio Lin HY-FCC part 15C-BLE Ver.1.1 Page 7 of 62 Report No.: RF260509004-03-001 2. GENERAL INFORMATION 2.1 GENERAL DESCRIPTION OF EUT Sample No. POC260509004-S001 Product name Remote Control Model name B082-02-F7, B082-01-F7, B082N-03-F7, B082N-04-F7, B082BQ-02-F7, B082BQ-01-F7, B082-XX-ZY, B082Z-XX-ZY, B082ZZ-XX-ZY(XX=01-99, Z=A~Z, Y=1-9) Te…
Text truncated - open the document above for the full version.
30 N. GOULD ST. STE N SHERIDAN WY · SHERIDAN, Wyoming, 82801 · United States
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 2.00 mW |
Remote Control
Equipment Class
DTS - Digital Transmission System
AX3000 Dual Band Wi-Fi GPON Terminal
Equipment Class
NII - Unlicensed National Information Infrastructure TX
AX3000 Dual Band Wi-Fi GPON Terminal
Equipment Class
DTS - Digital Transmission System4K OTT BOX
Equipment Class
DTS - Digital Transmission SystemWINBOX
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter