2AW8RCR400Portable Intelligent Cable Reel

Intradin (Shanghai) Machinery Co., Ltd
Portable Intelligent Cable Reel - FCC ID 2AW8RCR400 - Intradin (Shanghai) Machinery Co., Ltd
Click to zoom

Application Details

Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Date of Grant
Mar 23, 2021
Application Purpose
Original Equipment
Date of Application
Mar 22, 2021
Equipment Note
Portable Intelligent Cable Reel
Frequency Range
433.92000000 - 433.92000000
Company
Intradin (Shanghai) Machinery Co., Ltd
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

ALPHAWORKS SMART CORD REEL OPERATOR' MANUAL FCCID:2AW8RCR400 IC:26378-CR400 1 TECHNICAL DETAILS Item No. AWG Length (ft) Volt (V) Ampere (A) GUR052 12 65 125 15 SAFETY PRECAUTIONS Read carefully and understand all INSTRUCTIONS before operating. Failure to follow the safety rules and other basic safety precautions may result in serious personal injury. Save these instructions in a safe place and on hand so that they can be read when required. Keep these instructions to assist in future servicing. The warnings, cautions, and instructions discussed in this instruction manual cannot cover all possible conditions or situations that could occur. It must be understood by the operator that common sense and caution are factors which cannot be built into this product, but must be supplied by the operator. CORD REEL SAFETY PRECAUTIONS 1. Ensure that only the qualified electrician can installs/services this cord reel. And it must not be used by children or unskilled persons. 2. Ensure that power supply voltage does not exceed maximum voltage rating of reel. 3. Ensure that reel is properly be installed before connecting to power supply. 4. Ensure that all electrical power is removed from reel before servicing. 5. Check for frayed and broken wires before each use. 6. When pull electrical cord from the reel always grasp the electrical cord itself, not the work device. 7. Remove power from the reel immediately when any malfunction occurs. 8. Never remove, tamper with or cut the safety devices fitted by the manufacture. 9. Do not use the reel in damp or wet conditions. Keep the work area is clean. 14.42 8.78 7.80 4- 0.413 14.173 14.464 14.637 10.22 12.866 2 FCC Matters Needing Attention This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Caution: Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. This device contains licence-exempt transmitter(s)/receiver(s) that comply with Innovation, Science and Economic Development Canada’s licence-exempt RSS(s). Operation is subject to the following two conditions: (1) This device may not cause interference. (2) This device must accept any interference, including interference that may cause undesired operation of the device. L’émetteur/récepteur exempt de licence contenu dans le présent appareil est conforme aux CNR d’Innovation, Sciences et Développement économique Canada applicables aux appareils radio exempts de licence. L’exploitation est autorisée aux deux conditions suivantes : 1、 L’appareil ne doit pas produire de brouillage; 2、 L’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d’en compromettre le fonctionnement. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: —Reorient or relocate the receiving antenna. —Increase the separation between the equipment and receiver. —Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. —Consult the dealer or an experienced radio/TV technician for help. To satisfy FCC&IC RF exposure requirements, a separation distance of 20 cm or more should be maintained between the antenna of this device and persons during device operation. To ensure compliance, operations at closer than this distance is not recommended. Les antennes installées doivent être situées de facon à ce que la population ne puisse y être exposée à une distance de moin de 20 cm. Installer les antennes de facon à ce que le personnel ne puisse approcher à 20 cm ou moins de la position centrale de l’ antenne. 3 INSTALLATION 1. Unpack and inspect reel for damage. Check for completeness. 2. The cord reel must be installed in premises comforming to current regulation and standards covering systems and work environments. 3. Secure the cord reel to the wall and the ceiling according to the installation diagrams.Using screw anchors or suitable screws which must be fitted in the holes in the brackets. 4. The appliance can also be used on the ground. The cord reels can be placed in place as needed. In the ceiling on the wall on the ground OPERATION 1. Check reel for correct operation by slowly pulling out the cord. 2. To latch the reel, slowly pull out the cord to any point, release the cord to stop. NoteIt can not exceed the back end mark when the cord is pulled out. 4 CHECKLIST BEFORE USING THE DEVICE 1. In order to power up the sockets, first click each button, and check whether the indicator lights are working. 2. Your smart phone or tablet should have connected a 2.4G WIFI with internet. 3. The device only supports 2.4G network. Please don’t connect to a 5G network or hybrid network. 4. Enter correct WIFI passwords. Make sure that your WIFI SSID and passwords don’t contain special characters. 5. During pairing process, make sure that your IOS or Android device and smart socket within the range of the router. 6. Please pay attention to the maximum power that this socket. Retract the cord 1. Principal control: Press b…

Text truncated - open the document above for the full version.

Cover Letter(s)

lntradin (Shanahai) Machinerv Co .. Ltd Authoritv to Act as Al!ent Da te: 30-Seo-2020 American Certification Body, Inc. 6731 Whittier A venue Suite CllO McLean, VA 2 2101 To Whom It May Concern: Intertek Testing Services Shanghai is authorized to act on our behalf, until otherwise notified, for appl ications to American Certification Body, Inc. (ACB). We certify that we are not subje ct t o denial of federal benefits, that includes FCC benefits, pursuant t o Section 5301 of the Anti“Drug Abuse Act of 1988, 21 U.S.C. 862. Further, no party, as defined in 4 7 CF R 1.2002 (b), to the application is subject to denial of federal benefits, that includes FCC benefits. Thank you, Agency Agreement Expiration Date: 30-Seo-2021 fε�,, 『 ’‘·.』-一..---I B y: / /ψ〓 」....- (Signature 1 ) Title: M旦旦旦w: On behalf of: Int「adin (Shanohai) Machinerv Co .. Ltd (Company Name) Telephone: 86-021-64908190 MARK LEE (Print name) 1 - Mus t be sign巳d by applicant contact given for applicant on the FCC site, or by the authorized agent if an appropriate authoriz巳d ag巳nt letter has been provid巳d. L巳tters should be placed on appropriate letterhead.

Cover Letter(s)

lntradin (Shanahai) Machinerv Co .. Ltd Reauest for Confidentialitv Date: 30-Seo-2020 1. Subject: Confidentiality Request for: 2AW8RCR400 Pursuant to FCC 47 CFR 0.457(d) and 0.459 and IC RSP-100, Section 9.4, the applicant requests that a part of the subject FCC application be held confidential. Type of Confidentiality Requested 口ShortTerm囚Permanent 口Sho1tTerm 口ShortTerm 口Permanent* 1 口ShortTerm 因Permanent 口Sho1tTerm 口Permanent 口Sh01tTerm 口Permanent 口Sho1tTerm 因Permanent 口ShottTerm 口ShortTerm 口Permanent* 3 Exhibit Block Diagrams External Photos Internal Photos Operation Description/Theory of Operation Pa1ts List & Placement/BOM Tune-Up Procedure Schematics Test Setup Photos User ’ s Manual Intradin (Shan豆hai)Machinerv Co .. Ltd has spent substantial effort in developing this product and it is one of the first of its kind in industry. Having the subject information easily available t。 ” competition"would negate the advantage they have achieved by developing this product. Not protecting the details of the design will result in financial hardship. Permanent Confidentiality: The applicant requests the exhibits listed above as permanently confidential be permanently withheld from public r巳viewdue to materials that contain trade secrets and proprietary information not customarily released to the public. Short-Term Confidentiality: The applicant requests th巳exhibitsselected above as sho!t term confidential be withheld from public view for a period of ( speci fv number of da v s not to exceed 180}' _ days from the date of the Grant of Equipment Authorizat ion and prior to marketing. This is to avoid premature release of sensitive information prior to m arketing or r巳leaseof the product to the public. Applicant is also aware that they are r巳sponsibleto notify ACB in the event information r巳gardingthe product or the product is made available to the public before the requested period has expired. ACB will then release the documents listed above for public disclosure pursuant to FCC Public Notice DA 04-1705. NOTE for Industry Canada Applications: JC currently only distinguishes Permanent Confidentiality exhibits as shown above. Short Term confidentiality is not considered applicable to IC applications. Sincer巳ly, By : Manager MARK LEE � / (S j gnatu re/Ti tle J ) (Print name) 7侈n,Y ------- l“1节,;'asterked iten extend 巳d to th巳S巳exhibits.Pleas巳r巳fer to FCC KDB 726920 and the specific Docum巳nt I ink for DO I found at: httos://aoos. fcc.2:ov/oetcf/kdb/forms/FTSSearchResultPage.cfm?switch=P&id=41731 and review section II, 3) regarding specific information that must accompany these requests. 2 - Please refer to htto://acbcert.com/documents/misc-docs/Memo-Sho1t-Term-V s-Standard-Confidentialitv.odf for complete details. 3 -Must be signed by applicant contact given for applicant on th巳FCCsi饨,or by the authorized agent if an appropriate authorized agent le口erhas been provided. Letters should b巳placedon appropriate I巳tterhead.

Cover Letter(s)

Differentiation statement product name: Portabile Intelligent Cable Reel CR400 SJT/SJTW/SJTOW 12/14/16AWGX3C to 25FT~80FT GUR052 SJT/SJTW/SJTOW 12AWGX3C to 25FT~80FT GUR053 SJT/SJTW/SJTOW 14AWGX3C to 25FT~80FT GUR054 SJT/SJTW/SJTOW 16AWGX3C to 25FT~80FT Different models correspond to different wire specifications 1 2-24-2020 They are electrically same except for power cable.

External Photos

External Photo

ID Label/Location Info

Item No.: CR400 65FT. 12AWG CORD REEL Patent Pending Item No.: GUR052 65FT. 12AWG CORD REEL Patent Pending Item No.: GUR053 65FT. 12AWG CORD REEL Patent Pending Item No.: GUR054 65FT. 12AWG CORD REEL Patent Pending Labeling1Labeling1Labeling1 Labeling1 Labeling1 Labeling2 135 48.6 Labeling1 Location Labeling1 Labeling2 Location Labeling2

Internal Photos

Internal Photo Wi-Fi Antenna 433MHz SRD Antenna Wi-Fi Module 433MHz SRD module

RF Exposure Info

Intradin (Shanghai) Machinery Co., Ltd. MPE ASSESSMENT REPORT Report Type: FCC MPE assessment report Model: CR400, GUR052, GUR053, GUR054 REPORT NUMBER: 200800320SHA-003 ISSUE DATE: Dec 10, 2020 DOCUMENT CONTROL NUMBER: TTRFFCCMPE-01_V1 © 2018 Intertek Intertek Testing Services Shanghai Building No.86, 1198 Qinzhou Road (North) Caohejing Development Zone Shanghai 200233, China Telephone: 86 21 6127 8200 www.intertek.com TEST REPORT This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to permit copying or distribution of this report and then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test results in this report are relevant only to the sample tested. This report by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. TTRFFCCMPE-01_V1© 2018 Intertek Page 2 of 8 Report no.: 200800320SHA-003 Applicant: Intradin (Shanghai) Machinery Co., Ltd. No. 118, Duhui Road, Minhang District, Shanghai, China. Manufacturer: Intradin (Shanghai) Machinery Co., Ltd. No. 118, Duhui Road, Minhang District, Shanghai, China. Factory: Intradin (HuZhou) Precision Technology Co., Ltd. 1088 GanShan Road, Wuxing District, HuZhou, Zhejiang Province, 313005 China. FCC ID: 2AW8RCR400 SUMMARY: The equipment complies with the requirements according to the following standard(s) or Specification: KDB447498 D01 General RF Exposure Guidance v06 FCC Part2.1091, FCC Part2.1093 FCC Part1.1307(b) PREPARED BY: REVIEWED BY: Project Engineer Colin Sun Reviewer Daniel Zhao Report No.: 200800320SHA-003 TEST REPORT TTRFFCCMPE-01_V1© 2018 Intertek Page 3 of 8 Revision History Report No. Version Description Issued Date 200800320SHA-003 Rev. 01 Initial issue of report December 10, 2020 Report No.: 200800320SHA-003 TEST REPORT TTRFFCCMPE-01_V1© 2018 Intertek Page 4 of 8 1 GENERAL INFORMATION 1.1 Description of Equipment Under Test (EUT) Product name: Portable Intelligent Cable Reel Type/Model: CR400, GUR052, GUR053, GUR054 Description of EUT: EUT is portable intelligent cable reel with WiFi and 433 function, and there are three models, they are same except Brand name & Model No. We test CR400 as representative and list the worst results in this report. Rating: 120V~, 60Hz, 15A Category of EUT: Class B EUT type: Table top Floor standing Software Version: / Hardware Version: / Sample received date: September 10, 2020 Date of test: September 12, 2020 ~ November 25, 2020 1.2 Technical Specification Frequency Range: 2412MHz ~ 2462MHz for 802.11 b, g, n(HT20) 2422MHz ~ 2452MHz for 802.11 n(HT40) Support Standards: IEEE 802.11b, IEEE 802.11g, IEEE 802.11n(HT20), IEEE 802.11n(HT40) Type of Modulation: IEEE 802.11b: DSSS (CCK, DQPSK, DBPSK) IEEE 802.11g: OFDM (64-QAM, 16-QAM, QPSK, BPSK) IEEE 802.11n(HT20): OFDM (64-QAM, 16-QAM, QPSK, BPSK) IEEE 802.11n(HT40): OFDM (64-QAM, 16-QAM, QPSK, BPSK) Channel Number: 11 Channels for 802.11b, 802.11g and 802.11n(HT20) 7 Channels for 802.11n(HT40) Channel Separation: 5 MHz Antenna Information: PCB Antenna Antenna gain: 2.5dBi Frequency Range: 433.92MHz Type of Modulation: ASK Channel Number: 1 Channel Antenna Designation: Integral PCB antenna, non-user removable Gain of Antenna: 0dBi max (Declared by manufacturer) Report No.: 200800320SHA-003 TEST REPORT TTRFFCCMPE-01_V1© 2018 Intertek Page 5 of 8 1.3 Description of Test Facility Name: Intertek Testing Services Shanghai Address: Building 86, No. 1198 Qinzhou Road(North), Shanghai 200233, P.R. China Telephone: 86 21 61278200 Telefax: 86 21 54262353 The test facility is recognized, certified, or accredited by these organizations: CNAS Accreditation Lab Registration No. CNAS L0139 FCC Accredited Lab Designation Number: CN1175 IC Registration Lab Registration code No.: 2042B-1 VCCI Registration Lab Registration No.: R-4243, G-845, C-4723, T-2252 A2LA Accreditation Lab Certificate Number: 3309.02 Report No.: 200800320SHA-003 TEST REPORT TTRFFCCMPE-01_V1© 2018 Intertek Page 6 of 8 2 MPE Assessment Test result: Pass 2.1 MPE Assessment Limit Mobile device exposure for standalone operations: Frequency range E-field strength (V/m) H-field strength (A/m) B-field (uT) Equivalent plane wave power density S eq (W/m 2 ) 0-1 Hz - 3,2 × 10 4 4 × 10 4 - 1-8 Hz 10 000 3,2 × 10 4 /f 2 4 × 10 4 /f 2 - 8-25 Hz 10 000 4 000/f 5 000/f - 0,025-0,8 kHz 250/f 4/f 5/f - 0,8-3 kHz 250/f 5 6,25 - 3-150 kHz 87 5 6,25 - 0,15-1 MHz 87 0,73/f 0,92/f - 1-10 MHz 87/f 1/2 0,73/f 0,92/f - 10-400 MHz 28 0,073 0,092 2 400-2 000 MHz 1,375 f 1/2 0,0037 f 1/2 0,0046 f 1/2 f/200 2-300 GHz 61 0,16 0,20 10 Mobile device exposure for simultaneous transmission operations: the sum of the MPE ratios for all simultaneously transmitting antennas incorporated in a host device is ≤ 1.0 Report No.: 200800320SHA-003 TEST REPORT TTRFFCCMPE-01_V1© 2018 Intertek Page 7 of 8 2.2 Assessment Results Power density (S) is calculated according to the formula: S = P / (4πR²) Where S = power density in mW/cm² P = Radiated transmit power in mW G = numeric gain of transmit antenna R = distance (cm) As we can see from the test report 200702555SHA-001 and 200702555SHA-002: Function EIRP P Distance R (cm) Power density S (mW/cm²) Wi-Fi 22.25 dBm 20 0.0224 SRD 92.70 dBuV/m 20 0.0002 The device supports simultaneous transmission, and the sum of the MPE ratios = 0.0224 + 0.0002 = 0.0226 < 1 Report No.: 200800320SHA-003 TEST REPORT TTRFFCCMPE-01_V1© 2018 Intertek Page 8 of 8 Appendix I Definition below must be outlined in the…

Text truncated - open the document above for the full version.

Test Report

Intradin (Shanghai) Machinery Co., Ltd. RF TEST REPORT Report Type: FCC Part 15.231 & ISED RSS-210 RF report Model: CR400, GUR052, GUR053, GUR054 REPORT NUMBER: 200800320SHA-002 ISSUE DATE: December 3, 2020 DOCUMENT CONTROL NUMBER: TTRF15.231_V1 © 2018 Intertek Intertek Testing Services Shanghai Building No.86, 1198 Qinzhou Road (North) Caohejing Development Zone Shanghai 200233, China Telephone: 86 21 6127 8200 www.intertek.com TEST REPORT This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to permit copying or distribution of this report and then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test results in this report are relevant only to the sample tested. This report by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. TTRF15.231_V1 © 2018 Intertek Page 2 of 27 Report no.: 200800320SHA-002 Applicant: Intradin (Shanghai) Machinery Co., Ltd. No. 118, Duhui Road, Minhang District, Shanghai, China. Manufacturer: Intradin (Shanghai) Machinery Co., Ltd. No. 118, Duhui Road, Minhang District, Shanghai, China. Factory: Intradin (HuZhou) Precision Technology Co., Ltd. 1088 GanShan Road, Wuxing District, HuZhou, Zhejiang Province, 313005 China. FCC ID: 2AW8RCR400 IC: 26378-CR400 SUMMARY: The equipment complies with the requirements according to the following standard(s) or Specification: 47CFR Part 15 (2019): Radio Frequency Devices (Subpart C) ANSI C63.10 (2013): American National Standard of Procedures for Compliance Testing of Unlicensed Wireless Devices RSS-210 Issue 10 (December 2019): Licence-Exempt Radio Apparatus: Category I Equipment RSS-Gen Issue 5 Amendment 1 (March 2019): General Requirements for Compliance of Radio Apparatus PREPARED BY: REVIEWED BY: Project Engineer Colin Sun Reviewer Daniel Zhao Report No.: 200800320SHA-002 TEST REPORT TTRF15.231_V1 © 2018 Intertek Page 3 of 27 Content REVISION HISTORY................................................................................................................................................ 4 MEASUREMENT RESULT SUMMARY ..................................................................................................................... 5 1 GENERAL INFORMATION ............................................................................................................................. 6 1.1 DESCRIPTION OF EQUIPMENT UNDER TEST (EUT) ..................................................................................................... 6 1.2 TECHNICAL SPECIFICATION .................................................................................................................................... 6 1.3 DESCRIPTION OF TEST FACILITY .............................................................................................................................. 7 2 TEST SPECIFICATIONS ................................................................................................................................... 8 2.1 STANDARDS OR SPECIFICATIONP .............................................................................................................................. 8 2.2 MODE OF OPERATION DURING THE TEST ................................................................................................................... 8 2.3 TEST SOFTWARE LIST ............................................................................................................................................ 8 2.4 TEST PERIPHERALS LIST ......................................................................................................................................... 8 2.5 TEST ENVIRONMENT CONDITION: ............................................................................................................................ 9 2.6 INSTRUMENT LIST .............................................................................................................................................. 10 2.7 MEASUREMENT UNCERTAINTY ............................................................................................................................. 11 3 FUNDAMENTAL & SPURIOUS EMISSION & RESTRICT BAND RADIATED EMISSION ...................................... 12 3.1 LIMIT .............................................................................................................................................................. 12 3.2 MEASUREMENT PROCEDURE ............................................................................................................................... 13 3.3 TEST CONFIGURATION ........................................................................................................................................ 14 3.4 TEST RESULTS OF RADIATED EMISSIONS ................................................................................................................. 15 4 POWER LINE CONDUCTED EMISSION ......................................................................................................... 19 4.1 LIMIT .............................................................................................................................................................. 19 4.2 TEST CONFIGURATION ........................................................................................................................................ 19 4.3 MEASUREMENT PROCEDURE .......................................................................…

Text truncated - open the document above for the full version.

Test Setup Photos

Test Setup 1. RF conducted emission 2. Mains conducted emission 3. Radiated emission lower than 1GHz 4. Radiated emission higher than 1GHz

Contact Information

Applicant

Mark Lee
[email protected]86-21-6490 8190Fax: 86-21-6490 8190

Technical Contact

Intertek Testing Services ShanghaiColin Sun
[email protected]86 21 61215169

Building No.86, 1198 Qinzhou Road(North) · Shanghai · China

Test Firm

Intertek Testing Services ShanghaiLeah Xu
[email protected]+86 21 61278200

Technical Specifications

#Rule PartsFrequency RangePower Output
115.231433.92 MHz - 433.92 MHz-
Confidentiality
Long Term
Grant Notes
This device contains a 2.4GHz WIFI transmitter.