
Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
FCC Statement Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: -- Reorient or relocate the receiving antenna. -- Increase the separation between the equipment and receiver. -- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -- Consult the dealer or an experienced radio/TV technician for help This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions (1)this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body.
UBRIDGECo.,Ltd. 2021-05-13 To: FederalCommunicationsCommission AuthorizationandEvaluationDivision 7435OaklandMillsRoad Columbia,MD FCCID:2AWC3-MG-P01 ToWhomItMayConcern: ThisletteristoascertainthatUBRIDGECo.,Ltd.ProductAndroidboxhasbeenthe unitsusedforconductingFCCcompliancetesting,thesDoCpartwillbetestedbyFCC accreditedtestlab. TheresultshowsthattheEUThascompliedtounintentionalRadiators requirements(15.101). Testlabinformation: FCC-RegistrationNo.:645098 ShenzhenTongceTestingLab Adress:TCTTestingIndustrialParkFuqiao5thIndust.Zone,FuhaiStreet, Bao'anDist,Shenzhen,Guangdong,518103,China Ifyouhaveanyquestionorconcerns, pls.contactus.Sincerely, (signed) Name/Title:HeewonJeong/Business Company:UBRIDGECo.,Ltd. Address:1-1704,AceHightechCity,775,Gyeongin-ro,Yeongdeungpo-gu, Seoul,SouthKorea Phone:02-3439-0614 Fax:N/A Email:[email protected]
UBRIDGECo.,Ltd. OfficeofEngineeringTechnology FederalCommunicationsCommission 7435OaklandMillsRoad Columbia,MD21046 USA Date:2021-05-12 Subject;RequestforLongTermConfidentiality FCCID:2AWC3-MG-P01 ToWhomItMayConcern, PursuanttotheprovisionsoftheCommission’srulesTitle47Sections§0.457and§0.459,we arerequestingtheCommissiontowithholdthefollowingattachment(s)asconfidential documentsfrompublicdisclosureindefinitely. Thesedocumentscontaindetailedsystemandequipmentdescriptionsandareconsideredas proprietaryinformationinoperationoftheequipment.Thepublicdisclosureofthesedocuments mightbeharmfultoourcompanyandwouldgivecompetitorsanunfairadvantageinthemarket. SchematicDiagram BlockDiagram PartsList OperationalDescription Tune-upProcedure Itisourunderstandingthatallmeasurementtestreports,FCCIDlabelformatand correspondenceduringthecertificationreviewprocesscannotbegrantedasconfidential documentsandthisinformationwillbeavailableforpublicreviewoncethegrantofequipment authorizationisissued. Sincerely, Signature: Name:HeewonJeong Title:Business
UBRIDGECo.,Ltd. 1-1704,AceHightechCity,775,Gyeongin-ro,Yeongdeungpo-gu, Seoul,SouthKorea AgentAuthorization Company:UBRIDGECo.,Ltd. Address:1-1704,AceHightechCity,775,Gyeongin-ro,Yeongdeungpo-gu,Seoul, SouthKorea ProductName:Androidbox ModelNumber(s):MG-P01 ProductDescription:Androidbox WeauthorizeMiCOMLabsInc.,575BoulderCourt,Pleasanton,California94566,USA, toactonourbehalfonallmattersconcerningthecertificationofabovenamed equipment. WedeclarethatMiCOMLabsInc.isallowedtoforwardallinformationrelatedtothe approvalandcertificationofequipmenttotheregulatoryagenciesasrequiredandto discussanyissuesconcerningtheapprovalapplication.Anyandallactscarriedoutby MiCOMLabsonourbehalfshallhavethesameeffectasactsofourown. Signature:Date:2021-05-12 Name:HeewonJeong Title:Business Company:UBRIDGECo.,Ltd.
MiCOM Labs, 575 Boulder Court, Pleasanton, CA 94566 Tel: +1 (925) 462-0304, Fax: +1 (925) 462-0306, Web: www.micomlabs.com Page 1 of 7 Doc#: Single Certification Service Agreement Rev 1.4 Certification Service Agreement Certification Service Agreement Introduction This Certification Service Agreement was written to cover the Scope of Service and Certification holder/ grantee responsibilities for the countires/domains that MiCOM Labs can issue compliance certificates under its ISO 17065 accreditation status – USA (FCC), Canada (ISED), Japan (MIC) and European Union. General Requirements This Service Agreement covers the requirements of the following four certification schemes as operated by MiCOM Labs Certification; Country Recognition Body Designation Identification No. USA Federal Communications Commission (FCC) TCB US0159 Canada Canada ISED FCB US0159 Japan MIC (Ministry of Internal Affairs and Communication) RCB R210 Europe European Commission NB NB 2280 1.The certification holder/grantee acknowledges and agrees to the following;- (a) always fulfills the certification requirements, including implementing appropriate changes when they are communicated by MiCOM Labs; (b) ensures the product for which a Certificate is issued always fulfils the product compliance requirements under the certification scheme and that all ongoing production of the certified product continues to fulfill the product requirements and agrees that if the conditions under which the Certification was issued are not met, that the Certification will not be valid and will be revoked; (c) makes all necessary arrangements for: 1) the conduct of the evaluation and surveillance (if required), including provision for examining documentation and records, and access to the relevant equipment, location(s), area(s), personnel, and certification holder / grantee's subcontractors; 2) investigation of complaints; 3) the participation of observers, if applicable; (d) makes claims regarding certification consistent with the scope of certification; (e) does not use its product certification in such a manner as to bring MiCOM Labs into disrepute and does not make any statement regarding its product certification that MiCOM Labs may consider misleading or unauthorized; (f) upon suspension, withdrawal, or termination of certification, the certification holder / grantee discontinues its use of all advertising matter that contains any reference thereto and takes action as required by the certification scheme (e.g. the return of certification documents) and takes any other required measures; (g) if the certification holder/ grantee provides copies of the certification documents to others, the documents shall be reproduced in their entirety or as specified in the certification scheme; MiCOM Labs, 575 Boulder Court, Pleasanton, CA 94566 Tel: +1 (925) 462-0304, Fax: +1 (925) 462-0306, Web: www.micomlabs.com Page 2 of 7 Doc#: Single Certification Service Agreement Rev 1.4 Certification Service Agreement (h) in making reference to its product certification in communication media such as documents, brochures or advertising, the certification holder/ grantee complies with the requirements of MiCOM Labs or as specified by the certification scheme; (i) complies with any requirements that may be prescribed in the certification scheme relating to the use of marks of conformity, and that conformity marks are only on specific products found to comply with the requirements, and on information related to the product; (j) keeps a record of all complaints made known to it relating to compliance with certification requirements and makes these records available to MiCOM Labs when requested, and: 1) takes appropriate action with respect to such complaints and any deficiencies found in products that affect compliance with the requirements for certification. 2) documents the actions taken. 2. MiCOM Labs will issue Certification that is valid for the specified equipment as it is presented at the time of certification. The certification holder / grantee will inform MiCOM Labs, without delay, of changes that may affect its ability to conform with any of the requirements under the certification scheme. Some examples of this may be, but are in no way limited to the following;- Product modifications; Changes in the chassis material, chassis gasket methodology / material, grounding, antenna gain, antenna type, shielding material, modification of transmissions lines, changes to transmission line matching circuitry, operating duty cycle, change of product usage, operating frequency, bandwidth, transmit power / EIRP); Changes to; the Legal, commercial, organizational status; contact address and production sites. Such modifications shall require additional approval in the form of a review and amendment to the original product certification and changes to the product certification records including the certificate. 3. MiCOM Labs shall exercise the control as specified by the certification scheme over ownership, use and display of licenses, certificates, marks of conformity, and any other mechanisms for indicating a product is certified. Incorrect references to the certification scheme, standards or misleading use of licenses, certificates, marks, or any other mechanism for indicating a product is certified, found in documentation or other publicity, shall be dealt with by suitable action by MiCOM Labs and/or the appropriate regulatory authority. 4. Confidentiality - MiCOM Labs will hold all forms and documents that make up the certification application confidential and will not release any information to third parties without written consent from the applicant. MiCOM Labs, 575 Boulder Court, Pleasanton, CA 94566 Tel: +1 (925) 462-0304, Fax: +1 (925) 462-0306, Web: www.micomlabs.com Page 3 of 7 Doc#: Single Certification Service Agreement Rev 1.4 Certification Service Agreement General Terms and Conditions: DOCUMENTATION Documentation required for evaluation of the certifi…
Text truncated - open the document above for the full version.
Page 1 of 3 Appendix B: Photographs of EUT Product: Android box Model: MG-P01 External Photos Page 2 of 3 Page 3 of 3
LabelArtworkandLocation Model:MG-P01 Label: Size:L*W=18*28mm Androidbox ModelNo.:MG-P01 FCCID:2AWC3-MG-P01 Thisdevicecomplieswithpart15oftheFCC rules.Operationissubjecttothefollowingtwo conditions(1)thisdevicemaynotcauseharmful interference,and(2)thisdevicemustacceptany interferencereceived,includinginterferencethat maycauseundesiredoperation. Location
Page 1 of 4 Appendix B: Photographs of EUT Product: Android box Model: MG-P01 Internal Photos BT/WIFI ANT Page 2 of 4 Page 3 of 4 Page 4 of 4
Maximum Permissible Exposure Applicable Standard According to §1.1307(b), systems operating under the provisions of this section shall be operated in a manner that ensure that the public is not exposed to radio frequency energy level in excess of the Commission’s guideline. For BT: Remark: 1) The maximum output power for antenna is -2.01dBm (0.63mW) at 2480MHz, 2.14dBi antenna gain(with 1.64 numeric antenna gain.) 2) For mobile or fixed location transmitters, no SAR consideration applied. The minimum separation generally be used is at least 20cm, even if the calculation indicate that the MPE distance would be lesser. Maximum Permissible Exposure output power= 0.63mW Numeric Antenna gain= 1.64 Substituting the MPE safe distance using d=20cm into above equation. Yields: S=0.000199*P*G Where P=Power in mW G=Numeric antenna gain S=Power density in mW/cm 2 Power density= 0.000206mW/cm 2 (For mobile or fixed location transmitters, the maximum power density is 1.0 mW/cm 2 even if the calculation indicates that the power density would be larger.) For WIFI: Remark: 1) The maximum output power for antenna is 17.56dBm (57.02mW) at 2437MHz, 2.14dBi antenna gain(with 1.64 numeric antenna gain.) 2) For mobile or fixed location transmitters, no SAR consideration applied. The minimum separation generally be used is at least 20cm, even if the calculation indicate that the MPE distance would be lesser. Maximum Permissible Exposure output power=57.02mW Numeric Antenna gain= 1.64 Substituting the MPE safe distance using d=20cm into above equation. Yields: S=0.000199*P*G Where P=Power in mW G=Numeric antenna gain S=Power density in mW/cm 2 Power density= 0.018609mW/cm 2 (For mobile or fixed location transmitters, the maximum power density is 1.0 mW/cm 2 even if the calculation indicates that the power density would be larger.)
Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com TEST REPORT FCC ID: 2AWC3-MG-P01 Product: Android box Model No.: MG-P01 Additional Model No.: N/A Trade Mark: N/A Report No.: TCT210419E034 Issued Date: May 10, 2021 Issued for: UBRIDGE Co., Ltd. 1-1704, Ace Hightech City, 775, Gyeongin-ro, Yeongdeungpo-gu, Seoul, South Korea Issued By: Shenzhen Tongce Testing Lab TCT Testing Industrial Park, Fuqiao 5th Industrial Zone, Fuhai Street, Bao'an District, Shenzhen, Guangdong, 518103, People's Republic of China TEL: +86-755-27673339 FAX: +86-755-27673332 Note: This report shall not be reproduced except in full, without the written approval of Shenzhen Tongce Testing Lab This document may be altered or revised by Shenzhen Tongce Testing Lab personnel only, and shall be noted in the revision section of the document. The test results in the report only apply to the tested sample. Report No.: TCT210419E034 Page 2 of 65 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com TABLE OF CONTENTS 1. Test Certification ..................................................................................... 3 2. Test Result Summary .............................................................................. 4 3. EUT Description ....................................................................................... 5 4. General Information ................................................................................. 6 4.1. Test environment and mode ................................................................................. 6 4.2. Description of Support Units ................................................................................ 6 5. Facilities and Accreditations .................................................................. 7 5.1. Facilities ................................................................................................................. 7 5.2. Location ................................................................................................................. 7 5.3. Measurement Uncertainty ..................................................................................... 7 6. Test Results and Measurement Data ..................................................... 8 6.1. Antenna requirement ............................................................................................ 8 6.2. Conducted Emission ............................................................................................. 9 6.3. Conducted Output Power ................................................................................... 13 6.4. 20dB Occupy Bandwidth .................................................................................... 18 6.5. Carrier Frequencies Separation ......................................................................... 23 6.6. Hopping Channel Number .................................................................................. 28 6.7. Dwell Time ............................................................................................................ 31 6.8. Pseudorandom Frequency Hopping Sequence ................................................ 36 6.9. Conducted Band Edge Measurement ................................................................ 37 6.10. Conducted Spurious Emission Measurement ................................................. 41 6.11. Radiated Spurious Emission Measurement .................................................... 45 Appendix A: Photographs of Test Setup Appendix B: Photographs of EUT Report No.: TCT210419E034 Page 3 of 65 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com 1. Test Certification Product: Android box Model No.: MG-P01 Additional Model No.: N/A Trade Mark: N/A Applicant: UBRIDGE Co., Ltd. Address: 1-1704, Ace Hightech City, 775, Gyeongin-ro, Yeongdeungpo-gu, Seoul, South Korea Manufacturer: Shenzhen Tomato Technology Co., Ltd Address: Room 1106, Huatong Building, SunGangDong Road, LuoHu District, Shenzhen, Guangdong Province, P.R.China 518022 Date of Test: Apr. 19, 2021 – May 08, 2021 Applicable Standards: FCC CFR Title 47 Part 15 Subpart C Section 15.247 FCC KDB 558074 D01 15.247 Meas Guidance v05r02 ANSI C63.10:2013 The above equipment has been tested by Shenzhen Tongce Testing Lab and found compliance with the requirements set forth in the technical standards mentioned above. The results of testing in this report apply only to the product/system, which was tested. Other similar equipment will not necessarily produce the same results due to production tolerance and measurement uncertainties. Tested By: Date: May 08, 2021 Aaron Mo Reviewed By: Date: May 10, 2021 Beryl Zhao Approved By: Date: May 10, 2021 Tomsin Report No.: TCT210419E034 Page 4 of 65 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com 2. Test Result Summary Requirement CFR 47 Section Result Antenna Requirement §15.203/§15.247 (c) PASS AC Power Line Conducted Emission §15.207 PASS Conducted Peak Output Power §15.247 (b)(1) PASS 20dB Occupied Bandwidth §15.247 (a)(1) PASS Carrier Frequencies Separation §15.247 (a)(1) PASS Hopping Channel Number §15.247 (a)(1) PASS Dwell Time §15.247 (a)(1) PASS Radiated Emission §15.205/§15.209 PASS Band Edge §15.247(d) PASS Note: 1. PASS: Test item meets the requirement. 2. Fail: Test item does not meet the requirement. 3. N/A: Test case does not apply to the test object. 4. The test result judgment is decided by the limit of test standard. Report No.: TCT210419E034 Page 5 of 65 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com 3. EUT Description Product: Android box Model No.: MG-P01 Additional Model No.: N/A Trade Mark: N/A Bluetooth Version: V4.1 Operation Frequency: 2402MHz~2480MHz Transfer Rate: 1/2/3 Mbits/s Number of Channel: 79 Modulation Type: GFSK, π/4-DQPSK, 8DPSK Modulation Technology: FHSS Antenna Type: Interna…
Text truncated - open the document above for the full version.
Page 1 of 2 Appendix A: Photographs of Test Setup Product: Android box Model: MG-P01 Radiated Emission Page 2 of 2 Conducted Emission
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 600.00 µW |

Android dongle
Equipment Class
DTS - Digital Transmission System
Android dongle
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Android dongle
Equipment Class
DTS - Digital Transmission System