Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Congratulations and thank you for purchasing your new Smart Foal Alarm! Welcome to the Smart Foal Instruction Manual Please read these instructions in full Battery care Completing a charge/discharge cycle 1-2 times throughout the year will maintain the condition of the battery. Simply turn the transmitter on (leaving the base station off) and allow the transmitter to run flat. Then recharge and store. This is particularly important if you have a year without any use at all. 2 Contents INTRODUCTION ___________________________________________________________ 3 WHAT’S IN THE BOX? _____________________________________________________ 3 GETTING TO KNOW THE PARTS ___________________________________________ 4 WIFI SETUP ............................................................................................................................ 7 Base Station Diagram ......................................................................................................................... 7 WiFi Base Station Antennae ............................................................................................................... 7 Power pack assembly ......................................................................................................................... 7 WiFi Configuration.............................................................................................................................. 8 Mount the transmitter on the mare ................................................................................................... 9 Configure the hardware alarm to suit your needs ........................................................................... 10 Fitting the Transmitter to the Halter ................................................................................................ 10 Testing the Transmitter .................................................................................................................... 11 .......................................................................................................................................................... 11 Positioning the WiFi Base Station..................................................................................................... 11 OPERATIONS ____________________________________________________________ 12 TRANSMITTER ....................................................................................................................... 12 Recharging the transmitter .............................................................................................................. 12 FREQUENTLY ASKED QUESTIONS AND TROUBLESHOOTING ______________ 13 WHAT IF I NEED LONGER RANGE? ........................................... ERROR! BOOKMARK NOT DEFINED. WHY DOESN’T THE POWER OK LIGHT COME ON WHEN I PLUG IN THE USB CABLE? .................... 13 I HAVE CHANGED MY WIFI PASSWORD, WHAT DO I DO? ............................................................ 13 CAN I IMPROVE THE PERFORMANCE OF MY BASE STATION? ...... ERROR! BOOKMARK NOT DEFINED. ADDITIONAL NOTES ON FITTING THE TRANSMITTER .................................................................. 13 ADDITIONAL SUPPORT ........................................................................................................... 15 RADIO NOTICE ...................................................................................................................... 15 \ Click on the page number to go straight there 3 Introduction The purpose of this instruction manual is to help you become familiar with the setup, function and operation of your Smart Foal product. If you want to stream your mares’ data, you need to use a computer or laptop with the screen saver and sleep settings disabled. This is necessary because a tablet or phone will cut their WiFi connection once the device has been asleep for a few minutes to conserve the battery life. If your phone won’t stream the Smart Foal webapp, how do you get alarms? That’s where Pushover comes in. Pushover is a third-party app that is designed for emergency warnings and alarms. Once installed and set up, Pushover allows you to configure notification sounds for different types of alarms. For example, the low battery alert could be a fairly mild noise, whereas you might like your ‘lying down’ alarm to wake the dead. The beauty of Pushover over SMS is that Pushover can use BOTH the mobile/cell phone network and WiFi networks. That way if you are in a remote location and don’t have phone coverage - but you do have WiFi - then you will still get alarms. If you are in town and out of range of WiFi - but you have mobile phone service - then you still get alarms. We have tried to cover as many bases as possible. But what if I don’t want to use WiFi? The Smart Foal base station has a hardware alarm that you can activate. If the mare lies down the hardware alarm will sound until you turn it off, or until the mare gets back up. There are three new features in Smart Foal HOME compared to the original version: 1. Automatic hardware alarm over ride. If you leave your alarm connected to WiFi with the switch set to AUTO and then the WiFi drops out in the middle of the night, the hardware alarm can turn itself on when the mare lies down – so you don’t miss out. 2. ‘Lost mare’ alert. This is a copy of the same function performed by the server. If your WiFi base station can’t contact a mare for 3 minutes or more the alarm will start to ‘chirp’. This feature can be disabled. Details in the next section. 3. Lying down is now as sensitive as the server based alarm. What’s in the box? Your Smart Foal box will include: Smart Foal transmitter WiFi Base Station (Receiver) USB charger cable Instruction manual 2 x antenna 1 x Magnetic antenna base International power pack with USB output If you have ordered additional products make sure they are in the box as well. Leather pouches are not included as part of the standard kit. They…
Text truncated - open the document above for the full version.
13 July 2020 CETCB 114 Olinda Drive Brea, CA 92823 To whom it may concern: This is a letter of authorization to accept Compatible Electronics, Inc., specifically including the employees of Compatible Electronics, as an Agent for Smart Foal Pty Ltd of 40 Gard Road Mount Cottrell VIC 3024, for a period of one year, to sign applications before the Commission on our behalf, to make representations to you on our behalf, and to receive and exchange data between our company and the Commission in connection with certification of the following Smart Foal Pty Ltd product: Smart Foal Foaling Alarm system and kits including the: Smart Foal Base station, Smart Foal Repeater, Smart Foal Transmitters under FCC Docket Number 20780 and General Docket Number 80-284 pursuant to Part l5 of FCC Rules and Regulations. Please also accept this letter as an attestation that neither Smart Foal Pty Ltd nor any of its officers, directors, or persons holding 5% or more of the outstanding stock or shares, voting or non-voting, have been denied federal benefits under section 5301 of the Anti- Drug-Abuse act of 1988,21 U.S.C. 853(a). In addition, Smart Foal Pty Ltd will notify the Federal Communications Commission if, at any time, the situation changes causing Smart Foal Pty Ltd to be denied federal benefits. If you have any further questions or need additional information, please feel free to give me a call at +61 404 905 084 Sincerely, Signed by Authorized Company Officer: Aimee Nizette Managing Director
1 July 13, 2020 Compatible Electronics TCB 114 Olinda Drive Brea, California 92823 Subject: TCB application submittal To whom it may concern: We, Smart Foal Pty Ltd would like to declare that the application being submitted for the device with FCC ID: 2AWQP-BSH20, has not been submitted to another TCB or FCC for certification. If you have any questions, please do not hesitate to contact us at +61 404 905 084 Sincerely, Signed by Authorized Company Officer: Aimee Nizette Managing Director Smart Foal Pty Ltd 40 Gard Road Mount Cottrell VIC 3024 Australia
1 July 13, 2020 Compatible Electronics TCB 114 Olinda Drive Brea, California 92823 Subject: Request for withholding from public disclosure the schematics, block diagrams, and operational description pursuant to an application for certification To whom it may concern: We, Smart Foal Pty Ltd, would like to request that all schematics, block diagrams, and operational descriptions submitted with the application for certification be withheld from public disclosure as per Section 0.459 of FCC Rules. This request is made under the provisions of Section 0.457 (d) of the Commission’s Rules, and Section 552 (b)(4) of the Freedom of Information Act. These sections authorize the withholding from public inspection, those materials which would be privileged as a matter of law if retained by the person submitting them, and materials which would not customarily be released to the public by that person. If you have any questions, please do not hesitate to contact us at +61 404 905 084. Sincerely, Signed by Authorized Company Officer: Aimee Nizette Managing Director Smart Foal Pty Ltd 40 Gard Road Mount Cottrell VIC 3024 Australia
Base Station FCC ID: 2AWQP-BSH20 External photos Page 1 of 2 Base Station FCC ID: 2AWQP-BSH20 External photos page 2 of 2
FCC ID: 2AWQP-BSH20 Internal Photos Page 1 of 2 FCC ID: 2AWQP-BSH20 Internal Photos Page 2 of 2
Page 1 of 9 EMC Technologies Pty. Ltd. ABN 82 057 105 549 Melbourne 176 Harrick Road Keilor Park, Vic 3042 Tel: +61 3 9365 1000 Sydney Unit 3/87 Station Road Seven Hills, NSW 2147 Tel: +61 2 9624 2777 Email: [email protected] Web: www.emctech.com.au Accredited for compliance with ISO/IEC 17025 - Testing. The results of tests, calibration and/or measurements included in this document are traceable to Australian/national standards. NATA is a signatory to the ILAC Mutual Recognition Arrangement for the mutual recognition of the equivalence of testing, medical testing, calibration and inspection reports. Except for the Certificate of Compliance, this document must only be reproduced in full. RF EXPOSURE REPORT REPORT NUMBER: M2003018-4 V2 TEST STANDARD: EN 62311: 2008 CLIENT: SMART FOAL PTY LTD DEVICE: SMART FOAL FOALING BASE STATION MODEL: PROTOTYPE DATE OF ISSUE: 14 JULY 2020 EMC Technologies Pty Ltd reports apply only to the specific samples tested under stated test conditions. It is the manufacturer’s responsibility to assure that additional production units of this model are manufactured with identical electrical and mechanical components. EMC Technologies Pty Ltd shall have no liability for any deductions, inferences or generalisations drawn by the client or others from EMC Technologies Pty Ltd issued reports. This report shall not be used to claim, constitute or imply product endorsement by EMC Technologies Pty Ltd. Page 2 of 9 Report No. M2003018-4 V2 Except for the Certificate of Compliance, this document must only be reproduced in full. REVISION TABLE Version Sec/Para Changed Change Made Date 1 Initial issue of document 14/05/2020 2 2 Deleted reference to repeater unit 14/07/2020 Page 3 of 9 Report No. M2003018-4 V2 Except for the Certificate of Compliance, this document must only be reproduced in full. CONTENTS Introduction ......................................................................................................................... 5 1.1 Laboratory Overview .................................................................................................. 5 1.2 Test Laboratory/Accreditations .................................................................................. 5 Device Details..................................................................................................................... 5 Reference levels are defined in Table 5 in ICNIRP guideline ............................................ 6 Uncertainty ......................................................................................................................... 7 ASsumptions in this Assessment ....................................................................................... 7 RF Exposure CALCULATIONS .......................................................................................... 8 Conclusion .......................................................................................................................... 9 Page 4 of 9 Report No. M2003018-4 V2 Except for the Certificate of Compliance, this document must only be reproduced in full. RF EXPOSURE REPORT Device: SMART FOAL FOALING BASE STATION Model Number: PROTOTYPE Serial Number: Pre-production unit Part Number: N/A Manufacturer: Smart Foal Tested for: Smart Foal Pty Ltd Address: 40 Gard Road, Mount Cottrell, Vic 3024 Phone Number: 0404905084 Contact: Aimee Nizette Email: [email protected] Standards: EN 62311:2008 Assessment of electronics and electrical equipment related to human exposure restriction fields (0Hz-300GHz) ICNIRP Guidelines:2020 Guideline for limiting exposure to time-averaging electric, magnetic and electromagnetic fields (100 kHz to 300 GHz) Result: Based on an assessment of the documentation provided the SMART FOAL FOALING BASE STATION PROTOTYPE complies with the RF exposure requirements of EN 62311. Refer to Report M2003018-4 V2 for full details Issue Date: 14 July 2020 Assessment Engineer: Peter Jakubiec Authorised Signatory: Emad Mansur Issued by: EMC Technologies Pty. Ltd., 176 Harrick Road, Keilor Park, VIC, 3042, Australia. Phone: +61 3 9365 1000 E-mail: [email protected] Web: www.emctech.com.au Page 5 of 9 Report No. M2003018-4 V2 Except for the Certificate of Compliance, this document must only be reproduced in full. INTRODUCTION This report details the RF exposure assessment performed on SMART FOAL FOALING BASE STATION PROTOTYPE. This report is prepared in accordance with EN 62311:2008, “Generic standard to demonstrate compliance with electronics and electrical apparatus with the basic restriction or reference level related to human exposure to electromagnetic fields (0Hz to 300 GHz)” The terms electromagnetic radiation (EMR) and electromagnetic energy (EME) and Electromagnetic Fields (EMF) have the same meaning when used in this report. 1.1 Laboratory Overview EMC Technologies Pty. Ltd. is an independently owned Australian company that is NATA accredited to ISO 17025 for both testing and calibration and ISO 17020 for Inspection. – Accreditation Number 5292. 1.2 Test Laboratory/Accreditations Inspection were performed at EMC Technologies' laboratory in Keilor Park, Victoria Australia. Table 1-1: Accreditations for Conformity Assessment Country/Region Body Australia/New Zealand NATA Accreditation Number: 5292 Europe European Union Notified Body Number: 0819 USA FCC Designation Number: AU0001 (Melb) Canada ISED Canada Company Number: 3569B(Melb) Japan VCCI Company Number: 785 Taiwan BSMI Lab Code SL2-IN-E-5001R DEVICE DETAILS (Information supplied by the Client) The SMART FOAL FOALING BASE STATION PROTOTYPE has Two RF modules, one for receiving and one for transmitting, each module is connected to an external monopole antenna. Transmit parameters were provided by the customer and are shown below: Table 2-1: Transmitter Parameters Wireless Interface (1): Proprietary (Receiver only) Module Brand and Model: CDEByyte E01-ML01SP4 Supported Frequencies: 2476 MHz in the 2400~2525 …
Text truncated - open the document above for the full version.
Page 1 of 35 EMC Technologies Pty. Ltd. is a signatory to the ILAC Mutual Recognition Arrangement for the mutual recognition of the equivalence of testing, medical testing, calibration and inspection reports. Except for the Certificate of Compliance, this document must only be reproduced in full. EMC Technologies Pty Ltd reports apply only to the specific samples tested under stated test conditions. It is the manufacturer’s responsibility to assure that additional production units of this model are manufactured with identical electrical and mechanical components. EMC Technologies Pty Ltd shall have no liability for any deductions, inferences or generalisations drawn by the client or others from EMC Technologies Pty Ltd issued reports. This report shall not be used to claim, constitute or imply product endorsement by EMC Technologies Pty Ltd. Accredited for compliance with ISO/IEC 17025 – Testing. The results of tests, calibration and/or measurements included in this document are traceable to Australian/national standards. NATA ABN 82 057 105 549 Melbourne 176 Harrick Road Keilor Park, Vic 3042 Tel: +61 3 9365 1000 Sydney Unit 3/87 Station Road Seven Hills, NSW 2147 Tel: +61 2 9624 2777 Email: [email protected] Web: www.emctech.com.au 47 CFR PART 15, SUBPART B TEST REPORT REPORT NUMBER: M2003018-9 TEST STANDARD: 47 CFR PART 15 RADIO FREQUENCY DEVICES SUBPART B – UNINTENTIONAL RADIATORS CLIENT: SMART FOAL PTY LTD DEVICE: SMART FOAL HOME MODELS: BASE STATION: 2.0 REPEATER: 1.2 TRANSMITTER: 1.9 DATE OF ISSUE: 17 JUNE 2020 Page 2 of 35 Report No. M2003018-9 Except for the Certificate of Compliance, this document must only be reproduced in full. Equipment Under Test (EUT) Base station Transmitter Repeater REVISION TABLE Version Sec/Para Changed Change Made Date 1 Initial issue of document 17/06/2020 Page 3 of 35 Report No. M2003018-9 Except for the Certificate of Compliance, this document must only be reproduced in full. CONTENTS 1 Introduction ......................................................................................................................... 5 1.1 Test Facility ................................................................................................................ 5 1.1.1 Company Overview ............................................................................................... 5 1.1.2 NATA Accreditation ............................................................................................... 5 1.2 Test Laboratory/Accreditations .................................................................................. 6 1.3 Units of Measurements .............................................................................................. 6 1.4 Test Equipment Calibration ....................................................................................... 6 1.5 Test Configuration ..................................................................................................... 6 2 Test Procedure ................................................................................................................... 6 2.1 Summary of Test Results .......................................................................................... 6 2.2 General Information ................................................................................................... 7 2.3 Description supplied by Client ................................................................................... 7 2.4 Test sample block diagrams ...................................................................................... 8 2.5 Operating Conditions ................................................................................................. 9 2.6 Modifications .............................................................................................................. 9 3 Conducted Emissions Measurements .............................................................................. 10 3.1 Test Procedure ........................................................................................................ 10 3.2 Peak Maximising Procedure .................................................................................... 10 3.3 Calculation of Voltage Levels .................................................................................. 10 3.4 Plotting of Conducted Emission Measurement Data ............................................... 10 3.5 Test Results ............................................................................................................. 11 3.5.1 AC Mains power ports – Base Station ................................................................. 11 3.5.2 AC Mains power ports – Transmitter ................................................................... 13 3.5.3 AC Mains power ports – Repeater ....................................................................... 15 4 Radiated Emissions Measurements ................................................................................. 17 4.1 Test Procedure ........................................................................................................ 17 4.2 Plotting of Measurement Data for Radiated Emissions ........................................... 17 4.3 Calculation of Field Strength .................................................................................... 17 4.3.1 Test Results 30 – 1000 MHz ............................................................................... 18 4.3.2 Test Results Above 1 GHz Results ..................................................................... 20 5 Compliance Statement ..................................................................................................... 21 6 Measurement Uncertainty ................................................................................................ 22 Appendix A -Test Equipment ................................................................................................... 23 Appendix B - …
Text truncated - open the document above for the full version.
Base Station FCCID: 2AQWP-BSH20 Transmitter FCC ID: 2AWQP-TXH20 Repeater FCC ID: 2AQWP-RPH20 Report No. M2003018-9 Appendix C photos Base Station FCCID: 2AQWP-BSH20 Transmitter FCC ID: 2AWQP-TXH20 Repeater FCC ID: 2AQWP-RPH20 Base Station FCCID: 2AQWP-BSH20 Transmitter FCC ID: 2AWQP-TXH20 Repeater FCC ID: 2AQWP-RPH20 Base Station FCCID: 2AQWP-BSH20 Transmitter FCC ID: 2AWQP-TXH20 Repeater FCC ID: 2AQWP-RPH20 Base Station FCCID: 2AQWP-BSH20 Transmitter FCC ID: 2AWQP-TXH20 Repeater FCC ID: 2AQWP-RPH20 Base Station FCCID: 2AQWP-BSH20 Transmitter FCC ID: 2AWQP-TXH20 Repeater FCC ID: 2AQWP-RPH20
20621 Pascal Way · Lake Forest, California · United States
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15B | - | - |

Smart Foal Foaling Alarm System Transmitter
Equipment Class
JAB - Part 15 Class B Digital Device
Smart Foal Foaling Alarm System Repeater
Equipment Class
JAB - Part 15 Class B Digital Device