
Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Thank you for purchasing your new Eureka vacuum! Important instructions For easy assembly, please take a few moments to read this owner’s guide. If you have questions about your new vacuum, please contact our customer service HELPLINE at 1-800-282-2886. We’re here to help! Eureka stands by our Clean Promise seal. Learn more at www.eureka.com/cleanpromise www.eureka.com Owner’s Guide NER700 series Robotic vacuum cleaner; household type 2 Eureka Customer Service HELPLINE 1-800-282-2886 Contents FCC and Industry Canada Compliance Statement .........................3 Important safeguards. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 What comes in the carton ............................................5 How to identify parts of your vacuum cleaner .............................6 Easy assembly, How to charge battery ..................................7 How to use your robotic vacuum cleaner ................................8 How to set up app, connect WIFI and ues app ..........................8-9 How to maintain your vacuum cleaner How to maintain brushroll .................................10 ...........................................10 The Eureka limited warranty .........................................11 Thermal cut-off and problem solving ...................................12 How to dispose vacuum cleaner and battery pack ........................12 How to order replacement parts ......................................13 ! Follow caution information wherever you see this symbol. Write the model, type and serial number here: Date of purchase (keep your receipt) ______________ Model number and type _________________________ Serial number ________________________________ Find these numbers on a label on the hand vacuum, battery, and charger. Refer to these numbers when ordering parts and accessories, or if service is needed. : To register your product visit www.eureka.com link in the top right corner. : Carefully unpack and inspect your new Eureka vacuum cleaner for shipping damage. Each unit is tested and thoroughly inspected before shipping. For instructions regarding any shipping damage, call the Eureka Customer Service at 1-800-282-2886 immediately. www.eureka.com 3 This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. • Only operate the device in accordance with the instructions supplied. This device complies with FCC and IC radiation exposure limits set forth for an uncontrolled environment. In order to avoid the possibility of exceeding the FCC and IC radio frequency exposure limits, human proximity to the antenna shall not be less than 20cm (8 inches) during normal operation. approved by the party responsible for operate the equipment. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help. 4 Eureka Customer Service HELPLINE 1-800-282-2886 When using an electrical appliance, basic precautions should always be followed, including the following: This vacuum should not be used by children under the age of eight or those with reduced physical, sensory or mental capabilities without supervision. • Before using, clear area of power cords, pull cords for curtains or blinds, clothing and fragile items. • Do not operate in a room where a child or infant is sleeping. • Do not pour or spray any liquids on or in your robot. • If you live in an area that is prone to electrical storms, we recommend using a surge protector. • Do not operate the robot in a room that has lit candles or lit łreplace. • Do not allow children to sit on vacuum. • Do not use the docking station if it is damaged. • Do not operate in areas with exposed electrical outlets on the Ńoor. • Be aware that the robot moves around on its own. Take care when walking in the area when it is in operation. • Do not place the robot on any unstable surfaces. • Prevent unintentional starting. Ensure the switch is in the off-position before picking up or carrying the appliance. Carrying the appliance SEPDUKQNłnger on the switch or energizing appliance that has the switch on invites accidents. • Danger. Do not touch nozzle when the vacuum cleane r is on. • Do not put any object into openings. Do not use with any openings blocked; keep free of dust, lint, hair and anything that may reduce air Ńow. • Do not use outdoors or on wet surfaces. • Do not operate the vacuum cleaner or charger if it has been damaged in any way. If vacuum cleaner is not working as it should, has been dropped, damaged, left outdoors, or dropped into water or other liquid, call the Eureka Customer Service HELPLINE at 1-800-282-2886. • To avoid excessive heat and damage to the unit or battery, the vacuum cleaner will not operate while charging. • Do not allow to be used as a toy. Close attention is necessary when…
Text truncated - open the document above for the full version.
Declaration Letter We Jiangsu Midea Cleaning Appliances Co., Ltd.. hereby declare that the product Robot vacuum cleaner: NER700 is not capable of operating with channel 12 and 13 in regions of US and Canada. Versions of the product available for import and sale in the US and Canada will not operate on channels 12 and 13. It will not be possible for users and configure these channels in the US and Canada version. By: _______ Xiaofeng Yan _____ Title: Certification Engineer On behalf of: Jiangsu Midea Cleaning Appliances Co., Ltd. Telephone: 15996578260
Declaration We, Name: Jiangsu Midea Cleaning Appliances Co., Ltd. Address: No.39 Caohu Avenue, Xiangcheng Economic Development Zone, Suzhou, Jiangsu, China declare that NER700, NER700V and V8 have the same RF modular, the main PCB. NER700V is same as NER700 except for the figure, the color and the model name. V8 is same as NER700V except for the model name and the brand name. Declared by: Jiangsu Midea Cleaning Appliances Co., Ltd. Name: Xiaofeng Yan Signature: Date:2020-09-10
Declaration We, Name: Jiangsu Midea Cleaning Appliances Co., Ltd. Address: No.39 Caohu Avenue, Xiangcheng Economic Development Zone, Suzhou, Jiangsu, China declare that The WIFI modular contains two types of antenna: PCB antenna and PIFA antenna. In fact, only PIFA antenna is used, PCB antenna is cut off. Declared by: Jiangsu Midea Cleaning Appliances Co., Ltd. Name: Xiaofeng Yan Signature: Date:2020-07-10
Jiangsu Midea Cleaning Appliances Co., Ltd. Authority to Act as Agent Date: Jul 10, 2020 American Certification Body, Inc. 6731 Whittier Avenue Suite C110 McLean, VA 22101 To Whom It May Concern: _____Intertek Testing Service Shanghai______ is authorized to act on our behalf, until otherwise notified, for applications to American Certification Body, Inc. (ACB). We certify that we are not subject to denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 862. Further, no party, as defined in 47 CFR 1.2002 (b), to the application is subject to denial of federal benefits, that includes FCC benefits. We also declare that the information provided to the FCC is true and correct to the best of our knowledge (47 CFR 2.911(d)) and we have been informed of the grantee responsibilities (47 CFR 2.909) with regard to certified equipment. Thank you, Agency Agreement Expiration Date: _____Dec 31, 2021 By: _______________ ____ _Xiaofeng Yan____________ (Signature 1 ) (Print name) Title: ______ Certification Engineer ____________________ On behalf of: __ Jiangsu Midea Cleaning Appliances Co., Ltd.________________ (Company Name) Telephone: _____ 15996578260___________________ 1 - Must be signed by applicant contact given for applicant on the FCC site, or by the authorized agent if an appropriate authorized agent letter has been provided. Letters should be placed on appropriate letterhead.
Jiangsu Midea Cleaning Appliances Co., Ltd. Request for Confidentiality Date: Jul 10, 2020 Subject: Confidentiality Request for: __FCC ID: 2AWUS-MD001 Pursuant to FCC 47 CFR 0.457(d) and 0.459, the applicant requests that a part of the subject FCC application be held confidential. Type of Confidentiality Requested Exhibit ☐ Short Term ☒ Permanent Block Diagrams ☐ Short Term External Photos ☐ Short Term ☐ Permanent * 1 Internal Photos ☐ Short Term ☒ Permanent Operation Description/Theory of Operation ☐ Short Term ☐ Permanent Parts List & Placement/BOM ☐ Short Term ☐ Permanent Tune-Up Procedure ☐ Short Term ☒ Permanent Schematics ☐ Short Term Test Setup Photos ☐ Short Term ☐ Permanent * 3 User’s Manual ______ Jiangsu Midea Cleaning Appliances Co., Ltd. has spent substantial effort in developing this product and it is one of the first of its kind in industry. Having the subject information easily available to "competition" would negate the advantage they have achieved by developing this product. Not protecting the details of the design will result in financial hardship. Permanent Confidentiality: The applicant requests the exhibits listed above as permanently confidential be permanently withheld from public review due to materials that contain trade secrets and proprietary information not customarily released to the public. Short-Term Confidentiality: The applicant requests the exhibits selected above as short term confidential be withheld from public view for a period of ___(specify number of days not to exceed 180) 2 ___ days from the date of the Grant of Equipment Authorization and prior to marketing. This is to avoid premature release of sensitive information prior to marketing or release of the product to the public. Applicant is also aware that they are responsible to notify ACB in the event information regarding the product or the product is made available to the public before the requested period has expired. ACB will then release the documents listed above for public disclosure pursuant to FCC Public Notice DA 04-1705. NOTE for Industry Canada Applications: IC currently only distinguishes Permanent Confidentiality exhibits as shown above. Short Term confidentiality is not considered applicable to IC applications. Sincerely, By: Xiaofeng Yan (Signature/Title 3 ) (Print name) 1 - The asterisked items (*) require further information to be provided to ACB before permanent confidentiality will be extended to these exhibits. Please refer to FCC KDB 726920 and the specific Document link for D01 found at: https://apps.fcc.gov/oetcf/kdb/forms/FTSSearchResultPage.cfm?switch=P&id=41731 and review section II, 3) regarding specific information that must accompany these requests. 2 - Please refer to http://acbcert.com/documents/misc-docs/Memo-Short-Term-Vs-Standard-Confidentiality.pdf for complete details. 3 - Must be signed by applicant contact given for applicant on the FCC site, or by the authorized agent if an appropriate authorized agent letter has been provided. Letters should be placed on appropriate letterhead.
FCC ID: 2AWUS-MD001 Page 1 of 4 External Picture NER700 NER700 FCC ID: 2AWUS-MD001 Page 2 of 4 NER700 NER700 FCC ID: 2AWUS-MD001 Page 3 of 4 NER700 NER700 FCC ID: 2AWUS-MD001 Page 4 of 4 NER700 NER700V, V8
Page 1 of 1 Label location
Robot Vacuum Cleaner Rating Label PARSIPPANY, NJ 07054 MADE IN CHINA MODEL: NER700 14.4V Li-ion HOUSEHOLD TYPE FOR PARTS / SERVICE INFO (TOLL FREE) 1-800-282-2886 U C 70 18 04 000001 Brand CodeCategory CodeManufacturing siteYear of Production WeekSerial Code Code 128 135*35mm R=2mm 5001465 Conforms to UL Std.1017 FCC ID: 2AWUS-MD001 For use only with eureka NER700-DS Docking Station UC70184000001 S/N: UC70184000001 CAUTION – Risk Of Injury. Brush May Start Unexpectedly. Remove Main Brush Before Cleaning or Servicing This device complies with DHHS Radiation Rules, 21CFR Chapter 1,Subchapter J. CAN ICES-3(B)/NMB-3(B)
Robot Vacuum Cleaner Rating Label PARSIPPANY, NJ 07054 MADE IN CHINA MODEL: NER700V 14.4V Li-ion HOUSEHOLD TYPE FOR PARTS / SERVICE INFO (TOLL FREE) 1-800-282-2886 U C 70 18 04 000001 Brand CodeCategory CodeManufacturing siteYear of Production WeekSerial Code Code 128 135*35mm R=2mm 5001465 Conforms to UL Std.1017 FCC ID: 2AWUS-MD001 For use only with eureka NER700-DS Docking Station UC70184000001 S/N: UC70184000001 CAUTION – Risk Of Injury. Brush May Start Unexpectedly. Remove Main Brush Before Cleaning or Servicing This device complies with DHHS Radiation Rules, 21CFR Chapter 1,Subchapter J. CAN ICES-3(B)/NMB-3(B)
Robot Vacuum Cleaner Rating Label PARSIPPANY, NJ 07054 MADE IN CHINA MODEL: V8 14.4V Li-ion HOUSEHOLD TYPE FOR PARTS / SERVICE INFO (TOLL FREE) 1-800-282-2886 U C 70 18 04 000001 Brand CodeCategory CodeManufacturing siteYear of Production WeekSerial Code Code 128 135*35mm R=2mm 5001465 Conforms to UL Std.1017 FCC ID: 2AWUS-MD001 For use only with VEAVON V8-DS Docking Station UC70184000001 S/N: UC70184000001 CAUTION – Risk Of Injury. Brush May Start Unexpectedly. Remove Main Brush Before Cleaning or Servicing This device complies with DHHS Radiation Rules, 21CFR Chapter 1,Subchapter J. CAN ICES-3(B)/NMB-3(B)
FCC ID: 2AWUS-MD001 Page 1 of 11 Internal Picture FCC ID: 2AWUS-MD001 Page 2 of 11 FCC ID: 2AWUS-MD001 Page 3 of 11 Antenna FCC ID: 2AWUS-MD001 Page 4 of 11 FCC ID: 2AWUS-MD001 Page 5 of 11 FCC ID: 2AWUS-MD001 Page 6 of 11 FCC ID: 2AWUS-MD001 Page 7 of 11 FCC ID: 2AWUS-MD001 Page 8 of 11 FCC ID: 2AWUS-MD001 Page 9 of 11 FCC ID: 2AWUS-MD001 Page 10 of 11 FCC ID: 2AWUS-MD001 Page 11 of 11
Jiangsu Midea Cleaning Appliances Co., Ltd. MPE ASSESSMENT REPORT Report Type: FCC MPE assessment report Model: NER700, NER700V, V8 REPORT NUMBER: 200502363SHA-003 ISSUE DATE: Sep 22, 2020 DOCUMENT CONTROL NUMBER: TTRFFCCMPE-01_V1 © 2018 Intertek Intertek Testing Services Shanghai Building No.86, 1198 Qinzhou Road (North) Caohejing Development Zone Shanghai 200233, China Telephone: 86 21 6127 8200 www.intertek.com TEST REPORT This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to permit copying or distribution of this report and then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test results in this report are relevant only to the sample tested. This report by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. TTRFFCCMPE-01_V1© 2018 Intertek Page 2 of 9 Report no.: 200502363SHA-003 Applicant: Jiangsu Midea Cleaning Appliances Co., Ltd. No.39 Caohu Avenue, Xiangcheng Economic Development Zone, Suzhou, Jiangsu, China Manufacturer: Jiangsu Midea Cleaning Appliances Co., Ltd. No.39 Caohu Avenue, Xiangcheng Economic Development Zone, Suzhou, Jiangsu, China Manufacturing site: 1)Jiangsu Midea Cleaning Appliances Co., Ltd. No.39 Caohu Avenue, Xiangcheng Economic Development Zone, Suzhou, Jiangsu, China 2) Cape EMS Manufacturing (M) Sdn Bhd PLO 227A, Jalan Cyber 1A, Kawasan Perindustrian Senai III, 81400, Senai, Johor, Malaysia FCC ID: 2AWUS-MD001 SUMMARY: The equipment complies with the requirements according to the following standard(s) or Specification: KDB447498 D01 General RF Exposure Guidance v06 FCC Part2.1091, FCC Part2.1093 FCC Part1.1307(b) PREPARED BY: REVIEWED BY: Project Engineer Teddy Yin Reviewer Daniel Zhao Report No.: 200502363SHA-003 TEST REPORT TTRFFCCMPE-01_V1© 2018 Intertek Page 3 of 9 Revision History Report No. Version Description Issued Date 200502363SHA-003 Rev. 01 Initial issue of report Sep 22, 2020 Report No.: 200502363SHA-003 TEST REPORT TTRFFCCMPE-01_V1© 2018 Intertek Page 4 of 9 1 GENERAL INFORMATION 1.1 Description of Equipment Under Test (EUT) Product name: Robot vacuum cleaner Type/Model: NER700, NER700V, V8 Description of EUT: The EUT is automatically battery-powered cleaner and dry pick up for household indoor use only. NER700V is same as NER700 except for the figure, the color and the model name. V8 is same as NER700V except for the model name and the brand name. NER700 was tested as representative. NER700-DS, V8-DS are same except for the model name and the brand name. The EUT contains WIFI mode and BLE mode. Rating: DC 14.4V Charger: NER700-DS, V8-DS Input: 100-240V AC, 50-60Hz Output: DC 16.9V, 2A Category of EUT: Class B EUT type: Table top Floor standing Software Version: / Hardware Version: / Sample received date: May 27, 2020 Date of test: May 27~Jun 10, 2020 1.2 Technical Specification WIFI Frequency Range: 2412MHz ~ 2462MHz Support Standards: IEEE 802.11b, IEEE 802.11g, IEEE 802.11n-HT20 Type of Modulation: IEEE 802.11b: DSSS (CCK, DQPSK, DBPSK) IEEE 802.11g: OFDM (64-QAM, 16-QAM, QPSK, BPSK) IEEE 802.11n-HT20: OFDM (64-QAM, 16-QAM, QPSK, BPSK) Channel Number: 11 Channels for 802.11b, 802.11g and 802.11n(HT20) Data Rate: IEEE 802.11b: Up to 11 Mbps IEEE 802.11g: Up to 54 Mbps IEEE 802.11n-HT20: Up to MCS7 Channel Separation: 5 MHz Antenna Information: 3dBi, PIFA antenna BLE Frequency Range: 2402-2480MHz Support Standards: Bluetooth LE 4.2 Report No.: 200502363SHA-003 TEST REPORT TTRFFCCMPE-01_V1© 2018 Intertek Page 5 of 9 Type of Modulation: GFSK Channel Number: 40 Data Rate: 1Mbps Channel Separation: 2MHz Antenna Information: 3dBi, PIFA antenna Report No.: 200502363SHA-003 TEST REPORT TTRFFCCMPE-01_V1© 2018 Intertek Page 6 of 9 1.3 Description of Test Facility Name: Intertek Testing Services Shanghai Address: Building 86, No. 1198 Qinzhou Road(North), Shanghai 200233, P.R. China Telephone: 86 21 61278200 Telefax: 86 21 54262353 The test facility is recognized, certified, or accredited by these organizations: CNAS Accreditation Lab Registration No. CNAS L0139 FCC Accredited Lab Designation Number: CN1175 IC Registration Lab CAB identifier.: CN0051 VCCI Registration Lab Registration No.: R-14243, G-10845, C-14723, T-12252 A2LA Accreditation Lab Certificate Number: 3309.02 Report No.: 200502363SHA-003 TEST REPORT TTRFFCCMPE-01_V1© 2018 Intertek Page 7 of 9 2 MPE Assessment Test result: Pass 2.1 MPE Assessment Limit Mobile device exposure for standalone operations: Frequency range E-field strength (V/m) H-field strength (A/m) B-field (uT) Equivalent plane wave power density S eq (W/m 2 ) 0-1 Hz - 3,2 × 10 4 4 × 10 4 - 1-8 Hz 10 000 3,2 × 10 4 /f 2 4 × 10 4 /f 2 - 8-25 Hz 10 000 4 000/f 5 000/f - 0,025-0,8 kHz 250/f 4/f 5/f - 0,8-3 kHz 250/f 5 6,25 - 3-150 kHz 87 5 6,25 - 0,15-1 MHz 87 0,73/f 0,92/f - 1-10 MHz 87/f 1/2 0,73/f 0,92/f - 10-400 MHz 28 0,073 0,092 2 400-2 000 MHz 1,375 f 1/2 0,0037 f 1/2 0,0046 f 1/2 f/200 2-300 GHz 61 0,16 0,20 10 Mobile device exposure for simultaneous transmission operations: the sum of the MPE ratios for all simultaneously transmitting antennas incorporated in a host device is ≤ 1.0 Report No.: 200502363SHA-003 TEST REPORT TTRFFCCMPE-01_V1© 2018 Intertek Page 8 of 9 2.2 Assessment Results Power density (S) is calculated according to the formula: S = PG / (4πR²) Where S = power density in mW/cm² P = Radiated transmit power in mW G = numeric gain of transmit antenna R = distance (cm) As we can see from the test repo…
Text truncated - open the document above for the full version.
Jiangsu Midea Cleaning Appliances Co., Ltd. RF TEST REPORT Report Type: FCC Part 15.247 & ISED RSS-247 RF report Model: NER700, NER700V, V8 REPORT NUMBER: 200502363SHA-002 ISSUE DATE: Sep 22, 2020 DOCUMENT CONTROL NUMBER: TTRF15.247-02_V1 © 2018 Intertek Intertek Testing Services Shanghai Building No.86, 1198 Qinzhou Road (North) Caohejing Development Zone Shanghai 200233, China Telephone: 86 21 6127 8200 www.intertek.com TEST REPORT This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to permit copying or distribution of this report and then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test results in this report are relevant only to the sample tested. This report by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. TTRF15.247-02_V1 © 2018 Intertek Page 2 of 40 Report no.: 200502363SHA-002 Applicant: Jiangsu Midea Cleaning Appliances Co., Ltd. No.39 Caohu Avenue, Xiangcheng Economic Development Zone, Suzhou, Jiangsu, China Manufacturer: Jiangsu Midea Cleaning Appliances Co., Ltd. No.39 Caohu Avenue, Xiangcheng Economic Development Zone, Suzhou, Jiangsu, China Manufacturing site: 1)Jiangsu Midea Cleaning Appliances Co., Ltd. No.39 Caohu Avenue, Xiangcheng Economic Development Zone, Suzhou, Jiangsu, China 2) Cape EMS Manufacturing (M) Sdn Bhd PLO 227A, Jalan Cyber 1A, Kawasan Perindustrian Senai III, 81400, Senai, Johor, Malaysia FCC ID: 2AWUS-MD001 SUMMARY: The equipment complies with the requirements according to the following standard(s) or Specification: 47CFR Part 15 (2019): Radio Frequency Devices (Subpart C) ANSI C63.10 (2013): American National Standard of Procedures for Compliance Testing of Unlicensed Wireless Devices RSS-247 Issue 2 (February 2017): Digital Transmission Systems (DTSs), Frequency Hopping Systems (FHSs) and Licence-Exempt Local Area Network (LE-LAN) Devices RSS-Gen Issue 5 (April 2018): General Requirements for Compliance of Radio Apparatus PREPARED BY: REVIEWED BY: Project Engineer Teddy Yin Reviewer Daniel Zhao Report No.: 200502363SHA-002 TEST REPORT TTRF15.247-02_V1 © 2018 Intertek Page 3 of 40 Content REVISION HISTORY................................................................................................................................................ 5 MEASUREMENT RESULT SUMMARY ..................................................................................................................... 6 1 GENERAL INFORMATION ............................................................................................................................. 7 1.1 DESCRIPTION OF EQUIPMENT UNDER TEST (EUT) ..................................................................................................... 7 1.2 TECHNICAL SPECIFICATION .................................................................................................................................... 7 1.3 DESCRIPTION OF TEST FACILITY .............................................................................................................................. 8 2 TEST SPECIFICATIONS ................................................................................................................................... 9 2.1 STANDARDS OR SPECIFICATION ............................................................................................................................... 9 2.2 MODE OF OPERATION DURING THE TEST ................................................................................................................... 9 2.3 TEST SOFTWARE LIST .......................................................................................................................................... 10 2.4 TEST PERIPHERALS LIST ....................................................................................................................................... 10 2.5 TEST ENVIRONMENT CONDITION: .......................................................................................................................... 10 2.6 INSTRUMENT LIST .............................................................................................................................................. 11 2.7 MEASUREMENT UNCERTAINTY ............................................................................................................................. 12 3 MINIMUM 6DB BANDWIDTH ..................................................................................................................... 13 3.1 LIMIT .............................................................................................................................................................. 13 3.2 MEASUREMENT PROCEDURE ............................................................................................................................... 13 3.3 TEST CONFIGURATION ........................................................................................................................................ 13 3.4 TEST RESULTS OF MINIMUM 6DB BANDWIDTH ....................................................................................................... 13 4 MAXIMUM CONDUCTED OUTPUT POWER AND E.I.R.P. ............................................................................. 14 4.1 LIMIT .............................................................................................................................................................. 14 4.2 MEASU…
Text truncated - open the document above for the full version.
Jiangsu Midea Cleaning Appliances Co., Ltd. RF TEST REPORT Report Type: FCC Part 15.247 & ISED RSS-247 RF report Model: NER700, NER700V, V8 REPORT NUMBER: 200502363SHA-001 ISSUE DATE: Sep 22, 2020 DOCUMENT CONTROL NUMBER: TTRF15.247-03_V1 © 2018 Intertek Intertek Testing Services Shanghai Building No.86, 1198 Qinzhou Road (North) Caohejing Development Zone Shanghai 200233, China Telephone: 86 21 6127 8200 www.intertek.com TEST REPORT This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to permit copying or distribution of this report and then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test results in this report are relevant only to the sample tested. This report by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. TTRF15.247-03_V1 © 2018 Intertek Page 2 of 52 Report no.: 200502363SHA-001 Applicant: Jiangsu Midea Cleaning Appliances Co., Ltd. No.39 Caohu Avenue, Xiangcheng Economic Development Zone, Suzhou, Jiangsu, China Manufacturer: Jiangsu Midea Cleaning Appliances Co., Ltd. No.39 Caohu Avenue, Xiangcheng Economic Development Zone, Suzhou, Jiangsu, China Manufacturing site: 1)Jiangsu Midea Cleaning Appliances Co., Ltd. No.39 Caohu Avenue, Xiangcheng Economic Development Zone, Suzhou, Jiangsu, China 2) Cape EMS Manufacturing (M) Sdn Bhd PLO 227A, Jalan Cyber 1A, Kawasan Perindustrian Senai III, 81400, Senai, Johor, Malaysia FCC ID: 2AWUS-MD001 SUMMARY: The equipment complies with the requirements according to the following standard(s) or Specification: 47CFR Part 15 (2019): Radio Frequency Devices (Subpart C) ANSI C63.10 (2013): American National Standard of Procedures for Compliance Testing of Unlicensed Wireless Devices RSS-247 Issue 2 (February 2017): Digital Transmission Systems (DTSs), Frequency Hopping Systems (FHSs) and Licence-Exempt Local Area Network (LE-LAN) Devices RSS-Gen Issue 5 (April 2018): General Requirements for Compliance of Radio Apparatus PREPARED BY: REVIEWED BY: Project Engineer Teddy Yin Reviewer Daniel Zhao Report No.: 200502363SHA-001 TEST REPORT TTRF15.247-03_V1 © 2018 Intertek Page 3 of 52 Content REVISION HISTORY................................................................................................................................................ 5 MEASUREMENT RESULT SUMMARY ..................................................................................................................... 6 1 GENERAL INFORMATION ............................................................................................................................. 7 1.1 DESCRIPTION OF EQUIPMENT UNDER TEST (EUT) ..................................................................................................... 7 1.2 TECHNICAL SPECIFICATION .................................................................................................................................... 7 1.3 DESCRIPTION OF TEST FACILITY ...................................................…
Text truncated - open the document above for the full version.
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 2 | 15C | 2.40 GHz - 2.48 GHz | 3.00 mW |

Robot vacuum cleaner
Equipment Class
DTS - Digital Transmission System