Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Elektra GmbH U.S. Agent Designation for Service of Process - Certification Attestation Letter '10/16/2023 Federal Communications Commission A uthorization and Evaluation Division 7 435 Oakland Mills Road C olumbia, MD 21046 USA ATTN.: Reviewing Engineer FCC ID: 2AWW9RECEIVERMiX2ZB FRN of applicant: 0029770559 Per section 2.911 (d)(7) of the FCC rules, Elektra GmbH certifies that the equipment for which authorization is sought is designated to the following U.S. agent" for service of process: Company Name: UUX GROUP INC Physical U .S. Company Address: 36 South 18th Avenue, Suite A Brighton, CO USA 80601 County: Adams Contact Per son: Jack Fu Agent Email Address: uuxfo「[email protected] FRN: 0033701590 T he above contact person accepts the obligation for service of process. The applicant accepts to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any Commission-related proceeding involving the equipment 9eldra Gesellschaft fOr Applicant Sign 糙卧 rotechnische Gerate mbH Signed i�4. 及 .啼rkstraB立_ Printed name: Marius Hofmann Title: Approbation Company Name: Elektra GmbH Date: 10/16/2023 Agent Sig Signed: Printed name: Jack Fu Title: Manager Company Name: UUX GROUP INC Date: 10/16/2023 •the applicant must designate a contact located in the United States for purposes of acting as the applicant's agent for service of process, regardless of whether the applicant is a domestic o「foreign entity. An applicant located in the United States may designate itself as the agent for service of process.
Elektra GmbH Covered Equipment Certification Attestation Letter 10/16/2023 Federal Communications Commission Authorization and Evaluation Division 7 435 Oa kland Mills Road Columbia, MD 21046 USA ATTN.: Re viewing Engineer FCC ID: 2A扒9RECEIVERMIX2ZB Elektra GmbH certifies that the equipment for which authorization is sought is not "covered" equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. Note: If the equipment for which the applicant seeks authorization is produced by any of the entities identified on the current Covered List, the applicant should include an explanation on why the equipment is not "covered" equipment. Elektra GmbH certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing "covered" equipment. Signed: 「儿左 Elektra Gesellschaft filr 咄chnische Gerate rnbH 朵t咄e7 炒伈?坏0呵 Printed name: Marius Hofmann Title: Approbation Company Name: Elektra GmbH Date: 10/16/2023
Elektra GmbH DATE : 2023-10-16 Equipment Autorisation Division Federal Communications Commission 7435 Oakland Mills Road Columbia, M D 21046 F CC ID: 2AWW9RECEIVERMIX2ZB Product Name: LED-Controller Zigbee R equest for Confidentiality To Whom It May Concern, P ursuant to the provisions of the Commission's rules Title 47 Sections§0.457 and §0.459, we are requesting the Commission to withhold the following attachment(s) as confidential documents from public disclosure indefinitely. These documents contain detailed system and equipment descriptions and are considered as proprietary information in operation of the equipment. The public disclosure of these documents might be harmful to our company and would give competitors an unfair advantage in the market. 因SchematicDiagram 因BlockDiagram 因Operational Description In additional to above mentioned documents, in order to comply with the marketing regulations in Title 47 CFR§2.803 and the importation rules in Title 47 CFR§2.1204, while ensuring that business sensitive information remains confidential until the actual marketing of newly authorized devices, we request Short Term Confidentiality of the following attachment(s); 因ExternalPhotos 因TestSetup Photos 因InternalPhotos 因UserManual 口For 45 days, pursuant to Public Notice DA 04-1705. OR 因For180 days pursuantto KDB 726920 D01. It is our understanding that all measurement test reports, FCC ID label format and correspondence during the certification review process cannot be granted as confidential documents and this information will be available for public review once the grant of equipment authorization is issued. Elektra Gesellschaft fOr Signature: lektrotechnische Gerate mbH i.4,/1三�;: Name: Marius Hofmann Title: Approbation Company: Elektra GmbH
FCC ID : 2AWW9RECEIVERMIX2ZB 正面 背面 LED-Controller Zigbee Prog. 46.5 mm 46.5 mm
FCC ID: 2AWW9RECEIVERMIX2ZB RF Exposure Evaluation Limits The criteria listed in the following table shall be used to evaluate the environment impact of human exposure to radio frequency (RF) radiation as specified in 1.1307(b) Limits for Maximum Permissible Exposure (MPE) Frequency range (MHz) Electric field strength (V/m) Magnetic field strength (A/m) Power density (mW/cm 2 ) Averaging time (minutes) (A) Limits for Occupational/Controlled Exposures 0.3–3.0 614 1.63 *(100) 6 3.0–30 1842/f 4.89/f *(900/f 2 ) 6 30–300 61.4 0.163 1.0 6 300–1500 f/300 6 1500–100,000 5 6 (B) Limits for General Population/Uncontrolled Exposure 0.3–1.34 614 1.63 *(100) 30 1.34–30 824/f 2.19/f *(180/f 2 ) 30 30–300 27.5 0.073 0.2 30 300–1500 f/1500 30 1500–100,000 1.0 30 f = frequency in MHz Friis transmission formula: Pd = (Pout*G)/(4*pi*r 2 ) Where Pd = power density in mW/cm 2 , Pout = output power to antenna in mW; G = gain of antenna in linear scale, Pi = 3.1416; R = distance between observation point and center of the radiator in cm Pd id the limit of MPE, 1 mW/cm 2 . If we know the maximum gain of the antenna and the total power input to the antenna, through the calculation, we will know the distance r where the MPE limit is reached. Test Procedure Software provided by client enabled the EUT to transmit and receive data at lowest, middle and highest channel individually. FCC ID: 2AWW9RECEIVERMIX2ZB Test Result of RF Exposure Evaluation ZigBee mode Channel Output power to antenna (dBm) Output power to antenna (mW) Power Density at R=20cm (mW/cm2) Limit (mW/cm2) Result 2445MHz -0.11 0.97 0.0005 1.0 PASS Remark: antenna gain=4.07dBi The max power density is less than MPE exempt limit, so it is compliance.
Global United Technology Services Co., Ltd. Report No.: GTS2023090045F01 Authorized Signature: Robinson Luo Laboratory Manager This results shown in this test report refer only to the sample(s) tested, this test report cannot be reproduced, except in full, without prior written permission of the company. The report would be invalid without specific stamp of test institute and the signatures of compiler and approver. Page 1 of 30 TEST REPORT Applicant: Elektra GmbH Address of Applicant: Werkstrasse 7 D-32130, Enger, Germany Manufacturer/Factory: Elektra GmbH Address of Manufacturer/Factory: Werkstrasse 7 D-32130, Enger, Germany Equipment Under Test (EUT) Product Name: LED-Controller Zigbee Model No.: Receiver MIX-X2ZB FCC ID: 2AWW9RECEIVERMIX2ZB Applicable standards: FCC CFR Title 47 Part 15 Subpart C Section 15.247 Date of sample receipt: September 05, 2023 Date of Test: September 06, 2023-October 13, 2023 Date of report issued: October 16, 2023 Test Result : PASS * * In the configuration tested, the EUT complied with the standards specified above. Report No.: GTS2023090045F01 Global United Technology Services Co., Ltd. No. 123- 128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 2 of 30 2 Version Version No. Date Description 00 October 16, 2023 Original Prepared By: Date: October 16, 2023 Project Engineer Check By: Date: October 16, 2023 Reviewer Report No.: GTS2023090045F01 Global United Technology Services Co., Ltd. No. 123- 128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 3 of 30 3 Contents Page 1 COVER PAGE ........................................................................................................................................... 1 2 VERSION .................................................................................................................................................. 2 3 CONTENTS .............................................................................................................................................. 3 4 TEST SUMMARY ..................................................................................................................................... 4 4.1 MEASUREMENT UNCERTAINTY ............................................................................................................ 4 5 GENERAL INFORMATION ...................................................................................................................... 5 5.1 GENERAL DESCRIPTION OF EUT ......................................................................................................... 5 5.2 TEST MODE ........................................................................................................................................ 7 5.3 DESCRIPTION OF SUPPORT UNITS ....................................................................................................... 7 5.4 DEVIATION FROM STANDARDS ............................................................................................................. 7 5.5 ABNORMALITIES FROM STANDARD CONDITIONS ................................................................................... 7 5.6 TEST FACILITY .................................................................................................................................... 7 5.7 TEST LOCATION ................................................................................................................................. 7 5.8 ADDITIONAL INSTRUCTIONS ................................................................................................................. 7 6 TEST INSTRUMENTS LIST ..................................................................................................................... 8 7 TEST RESULTS AND MEASUREMENT DATA .................................................................................... 10 7.1 ANTENNA REQUIREMENT ................................................................................................................... 10 7.2 CONDUCTED PEAK OUTPUT POWER .................................................................................................. 11 7.3 CHANNEL BANDWIDTH ...................................................................................................................... 12 7.4 POWER SPECTRAL DENSITY ............................................................................................................. 13 7.5 SPURIOUS EMISSION IN NON-RESTRICTED & RESTRICTED BANDS ....................................................... 14 7.5.1 Conducted Emission Method ..................................................................................................... 14 7.5.2 Radiated Emission Method ........................................................................................................ 15 8 TEST SETUP PHOTO ............................................................................................................................ 30 9 EUT CONSTRUCTIONAL DETAILS ..................................................................................................... 30 Report No.: GTS2023090045F01 Global United Technology Services Co., Ltd. No. 123- 128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 4 of 30 4 Test Summary Test Item Section in CFR 47 Result Antenna requirement 15.203/15.247 (c) Pass AC Power Line Conducted Emission 15.207 N/A Conducted Peak Output Power 15.247 (b)(3) Pass Channel Bandwidth 15.247 (a)(2) Pass Power Spectral Density 15.247 (e) Pass Band Edge 15.247(d) Pass Spurious Emission 15.205/15.209 Pass Pass: …
Text truncated - open the document above for the full version.
Report No.: GTS2023090045F01 Global United Technology Services Co., Ltd. No. 123- 128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 1 of 19 1. Bandwidth 1.1 OBW 1.1.1 Test Result Mode TX Type Frequency (MHz) ANT 99% Occupied Bandwidth (MHz) Verdict Result O-QPSK SISO 2405 1 2.304 Pass 2445 1 2.307 Pass 2480 1 2.305 Pass Report No.: GTS2023090045F01 Global United Technology Services Co., Ltd. No. 123- 128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 2 of 19 1.1.2 Test Graph O-QPSK_LCH_2405MHz_Ant1_NTNV O-QPSK_MCH_2445MHz_Ant1_NTNV Report No.: GTS2023090045F01 Global United Technology Services Co., Ltd. No. 123- 128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 3 of 19 O-QPSK_HCH_2480MHz_Ant1_NTNV Report No.: GTS2023090045F01 Global United Technology Services Co., Ltd. No. 123- 128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 4 of 19 1.2 6dB BW 1.2.1 Test Result Mode TX Type Frequency (MHz) ANT 6dB Bandwidth (MHz) Verdict Result Limit O-QPSK SISO 2405 1 1.484 >=0.5 Pass 2445 1 1.468 >=0.5 Pass 2480 1 1.468 >=0.5 Pass Report No.: GTS2023090045F01 Global United Technology Services Co., Ltd. No. 123- 128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 5 of 19 1.2.2 Test Graph O-QPSK_LCH_2405MHz_Ant1_NTNV O-QPSK_MCH_2445MHz_Ant1_NTNV Report No.: GTS2023090045F01 Global United Technology Services Co., Ltd. No. 123- 128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 6 of 19 O-QPSK_HCH_2480MHz_Ant1_NTNV Report No.: GTS2023090045F01 Global United Technology Services Co., Ltd. No. 123- 128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 7 of 19 2. Maximum Conducted Output Power 2.1 Test Result Mode TX Type Frequency (MHz) Maximum Peak Conducted Output Power (dBm) Verdict ANT1 Limit O-QPSK SISO 2405 -0.22 <=30 Pass 2445 -0.11 <=30 Pass 2480 -0.17 <=30 Pass Report No.: GTS2023090045F01 Global United Technology Services Co., Ltd. No. 123- 128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 8 of 19 2.2 Test Graph O-QPSK_LCH_2405MHz_Ant1_NTNV O-QPSK_MCH_2445MHz_Ant1_NTNV Report No.: GTS2023090045F01 Global United Technology Services Co., Ltd. No. 123- 128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 9 of 19 O-QPSK_HCH_2480MHz_Ant1_NTNV Report No.: GTS2023090045F01 Global United Technology Services Co., Ltd. No. 123- 128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 10 of 19 3. Maximum Power Spectral Density 3.1 Test Result Mode TX Type Frequency (MHz) Maximum PSD (dBm/3kHz) Verdict ANT1 Limit O-QPSK SISO 2405 -15.36 <=8 Pass 2445 -15.26 <=8 Pass 2480 -15.38 <=8 Pass Report No.: GTS2023090045F01 Global United Technology Services Co., Ltd. No. 123- 128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 11 of 19 3.2 Test Graph O-QPSK_LCH_2405MHz_Ant1_NTNV O-QPSK_MCH_2445MHz_Ant1_NTNV Report No.: GTS2023090045F01 Global United Technology Services Co., Ltd. No. 123- 128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 12 of 19 O-QPSK_HCH_2480MHz_Ant1_NTNV Report No.: GTS2023090045F01 Global United Technology Services Co., Ltd. No. 123- 128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 13 of 19 4. Unwanted Emissions In Non-restricted Frequency Bands 4.1 Ref 4.1.1 Test Result Mode TX Type Frequency (MHz) ANT Level of Reference (dBm) O-QPSK SISO 2405 1 -2.25 2445 1 -2.13 2480 1 -2.16 Note1: Refer to FCC Part 15.247 (d) and ANSI C63.10-2013, the channel contains the maximum PSD level was used to establish the reference level. Report No.: GTS2023090045F01 Global United Technology Services Co., Ltd. No. 123- 128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 14 of 19 4.1.2 Test Graph O-QPSK_LCH_2405MHz_Ant1_NTNV O-QPSK_MCH_2445MHz_Ant1_NTNV Report No.: GTS2023090045F01 Global United Technology Services Co., Ltd. No. 123- 128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 15 of 19 O-QPSK_HCH_2480MHz_Ant1_NTN…
Text truncated - open the document above for the full version.
ReportNo.:RFI-LAB-RF-202309-II01 QP030-E41 Page1of10 TestingReport CustomerName:ShenzhenSunricherTechnologyLimited ProductName:ZigbeeModule SampleModel:MG21,MG22 ReferenceStandard:GB/T9410-2008;ANSI/IEEEStd149-1979 IssueDate:2023.9.13 Engineer:Date: Auditor:Date: Approver:Date: ReportNo.:RFI-LAB-RF-202309-II01 QP030-E41 Page2of10 Version VersionNo.DateDescriptionFormulateApproval A02023.09.13Forthefirsttime,formulateZkrisEason Contents 1.GeneralInformation.........................................................................................................................3 1.1Generalinformationoftestinginstitutions...........................................................................3 1.2Testingprinciple...................................................................................................................3 1.3Testequipment......................................................................................................................4 1.4Testenvironment...................................................................................................................4 1.5Statement..............................................................................................................................4 2.SampleInformation.........................................................................................................................5 2.1Clientinformation.................................................................................................................5 2.2DescriptionofEUT(S)..........................................................................................................5 2.3EUTappearance....................................................................................................................6 2.4EUTsetupphotooffreespaceOTAtesting.........................................................................6 3.TestResults.....................................................................................................................................7 3.1Teststandard.........................................................................................................................7 3.2Testuncertainty.....................................................................................................................7 3.3Testdata................................................................................................................................8 3.3.1VSWRparameters.....................................................................................................8 3.3.2VSWRdata................................................................................................................8 3.3.3Typicalfreespaceefficiencyandgain......................................................................8 3.3.4Typicalfreespaceradiationpattern...........................................................................9 (Thefollowingisblank)..............................................................................................................10 ReportNo.:RFI-LAB-RF-202309-II01 QP030-E41 Page3of10 1.GeneralInformation 1.1Generalinformationoftestinginstitutions Name ShenzhenRFI-LABCommunicationTechnologyCo.,Ltd. Address 10/FA,LingyunBld,LiufangRd,BaoanDistrict,SZ Tel 13682621346 E-mail [email protected] Equipment AlltheequipmentusedinthereportisfixedinZoneB,WestSideof1/F,Building1, TingweiIndustrialPark,No.6LiufangRoad,Bao'anDistrict,Shenzhen 1.2Testingprinciple ReportNo.:RFI-LAB-RF-202309-II01 QP030-E41 Page4of10 1.3Testequipment EquipmentModelNo.SerialNo.Manufacturer Calibration date Next calibration date OTATest System RayZone-5000 RFI-LAB-RF -D00 GTS2023.3.142025.3.13 Network Analyzer E5071C RFI-LAB-RF -D01 KEYSIGHT2023.5.112024.5.10 Network Analyzer E5071C RFI-LAB-RF -C02 KEYSIGHT2023.5.112024.5.10 1.4Testenvironment Temperature 23.5°C Humidity 58%RH Pressure 100.21kPa 1.5Statement (1)Thetestresultsinthereportareonlyapplicabletothetestedsamplesandthetestedsamples workundertheenvironmentdescribedinthereport. (2)OnlyShenzhenRFI-LABCommunicationTechnologyCo.,Ltd.havetherighttomodifythe report,andthemodificationinformationshallbeannotatedintherevisionform. (3)Anyobjectiontothisreportshallberaisedwithin30daysafterformalconfirmationofthe report. (4)Thisreportisinvalidifthereisanyevidencethatthesampleinformationprovidedisfalsified. (5)Thereportisinvalidwithoutthesignatureoftheauditorandapprover. ReportNo.:RFI-LAB-RF-202309-II01 QP030-E41 Page5of10 2.SampleInformation 2.1Clientinformation Name ShenzhenSunricherTechnologyLimited Address 3F&5F,BuildingE,QihangInnovationIndustrialPark,No.1008 SongbaiRoad,NanshanDistrict,Shenzhen,Guangdong518055China Contacts / Tel / E-mail / Manufacturer / Manufacturer Address / 2.2DescriptionofEUT(S) ProductName ZigbeeModule SampleModel MG21,MG22 AntennaSize / SerialNo. / AntennaType PCBAntenna TestItem VSWR;Antennagain;Efficiency;Radiationpattern FrequencyRange 2400-2500MHz ReceivedDate 2023.09.11 TestDate 2023.09.13 Remark / ReportNo.:RFI-LAB-RF-202309-II01 QP030-E41 Page6of10 2.3EUTappearance 2.4EUTsetupphotooffreespaceOTAtesting Planform Frontview ReportNo.:RFI-LAB-RF-202309-II01 QP030-E41 Page7of10 3.TestResults 3.1Teststandard NameParameterMethodStandardno. Mobile communication antenna Antennagain Genericspecification forantennasusedinthe mobilecommunications GB/T 9410-2008 Radiationpattern VSWR Antenna Radiationefficiency IEEEStandardTest ProceduresforAntennas ANSI/IEEEStd 149-1979 Gainanddirectivity 3.2Testuncertainty TheuncertaintywascalculatedonthebasisoftheGUMpublishedbyISO,usingthe inclusionfactorofK=2andthe95%confidenceleveltoexpresstheextended uncertainty. ItemUncertainty VSWR±0.3 Antennagain±0.72dB Radiationefficiency±0.72dB ReportNo.:RFI-LAB-RF-202309-II01 QP030-E41 Page8of10 3.3Testdata 3.3.1VSWRparameters 3.3.2VSWRdata 3.3.3Typicalfreespaceefficiencyandgain Frequency/MHz 240024502500 VSWR 1.73601.28121.5775 Frequency/MHz 24002410242024302440245024602470248024902500 Pe…
Text truncated - open the document above for the full version.
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 970.00 µW |

RF Wireless CCT Dimmer
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter