Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Automatic Upper Arm Blood Pressure Monitor Model: X3 Blood pressure measurements determined with X3 are equivalent to those obtained by a trained observer using cuff/stethoscope auscultation method, within the lim- its prescribed by the American National Standard, Electronic or Automated Sphyg- momanometers. This unit is to be used by adult consumers in a home environment. The patient is an intended operator. Do not use this device on whole pediatric popu- lation. X3 is protected against manufacturing defects by an established International Warranty Program. For warranty information, you can contact the manufacturer, GMC Inc. Attention: Consult the accompanying documents. Please read this manual carefully before use. For specific information on your own blood pressure, con- tact your physician. Please be sure to keep this manual. The GMC Upper Arm Automatic Blood Pressure Monitor, Model X3 is a non-invasive blood pressure measurement device that is used for measuring systolic and diastolic blood pressure and pulse rate using the oscillometric method for adults at home. The device has an irregular heartbeat (IHB) indicator. The device detects the appear- ance of an irregular heartbeat during measurement, and displays an IHB symbol on the LCD with the reading once the irregular heartbeat is detected. Introduction Indications For Use Real Fuzzy Measuring Technology Name/Function of Each Part Preliminary Remarks This blood pressure monitor complies with : • ISO 81060-2 :2013 Non-invasive sphygmomanometers - Part 2: Clinical validation of automated measurement type. • IEC 80601-2-30: 2018 Medical electrical equipment - Part 2-30: Particular require- ments for the basic safety and essential performance of automated non-invasive sphygmomanometers. • IEC 60601-1-2 : 2014 Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral Standard: Electromagnetic dis- turbances - Requirements and tests This blood pressure monitor was designed for long service time. Ensure continued accuracy, it’s recommended that all digital blood pressure monitors require re-calibra- tion. This monitor (under normal usage with approx. 3 measurements a day) does not require re-calibration for 2 years. Once the unit should be re-calibrated the device will display . The unit should also be re-calibrated if the monitor sustains damage due to blunt force (such as dropping) or exposure to fluids and / or extreme hot or cold temperature / humidity changes. When appears, simply return to your nearest dealer for re-calibration service. / grade 2 hypertension / grade 3 hypertension) of your result, making the meaning of your findings comprehensive. Blood Pressure Standard World Health Organization (WHO) : 1999 Systolic Pressure (mmHg) Diastolic Pressure (mmHg) Optimal <120 and <80 Normal 120~129 or 80~84 High-normal 130~139 or 85~89 Grade 1 hypertension (mild) 140~159 or 90~99 Grade 2 hypertension (moderate) 160~179 or 100~109 Grade 3 hypertension ≥180 or ≥110 1. Arm Cuff 2. LCD Display 3. Air Tube and Connector 4. Memory Key 5. ON/OFF/START key 1. Date/Time Indication 2. Weak Battery Mark 3. Movement Mark 4. Hypertension Risk Indication 5. Memory Mark 6. Memory Average Mark 7. Memory Zone 8. Systolic Pressure 9. Diastolic Pressure 10. Pulse Rate 11. Irregular Heartbeat Detection (IHB) 12. Pulse Mark This unit uses the oscillometric method to detect your blood pressure. Before the cuff starts inflating, the device will establish a baseline cuff pressure equivalent to the air pressure. This unit will automatically determine the appropriate inflation level based on pressure oscillations, followed by cuff deflation. During the deflation, the device will detect the amplitude and slope of the pressure oscillations and thereby determine your actual the systolic blood pressure, diastolic blood pressure, and pulse rate. 1 5 4 2 3 7 6 8 9 10 The “Movement Detection” helps reminding the user to remain still and is indicating any adverse body movement during measurement. The specified icon appears once a “body movement” has been detected during and after such a measurement. Note: It’s highly recommended that you measure again if the icon appears. This monitor has a non-stored single measurement function. Press the User-Switching key to select the memory zone of guest , and follow the Measurement Procedure to take a measurement correctly. When the measurement is completed, the measure- ment value will not be stored in memory zone. Refer to the definitions of the World Health Organization, the blood pressure ranges can be classified into 6 grades. (Ref. 1999 WHO-International Society of Hypertension Guidelines for the management of Hypertension). This blood pressure classification are based on historical data, and may not be directly applicable to any particular patient. It is important that you consult with your physician regularly. Your physician will tell you your normal blood pressure range as well as the point at which you will be considered at risk. For reliable monitoring and reference of blood pressure, keeping long- term re- cords is recommended. This unit is equipped with an innovative blood pressure risk indication, which visually indicates the assumed risk level (optimal / normal / high-normal/ grade 1 hypertension EE / Measurement Error: Make sure the L-plug is securely connected to the air sock- et and calmly measure again. Wrap the cuff correctly around your arm and keep arm steady during measurement. If the error keeps occurring, return the device to your local distributor or service centre. E1 / Air Circuit Abnormality: Make sure the L-Plug is securely connected to the air socket on the side of the unit and calmly measure again. If the errors still occur, return the device to your local distributor or service centre for help. E2 / Pressure Exceeding 300 mmHg: Switch the unit off and measure again quietly. If the error keeps occurring, return the device to your local d…
Text truncated - open the document above for the full version.
Pairing the Blood Pressure Monitor with your Smart- phone To begin using Bluetooth® for the first time, please visit the website at http://www.rossmax.com for the initial set-up instructions. 1. Download and install the applicable APP onto your smartphone. 2. To bind this device with your smartphone, turn on the device, Bluetooth® and the App of smartphone, and fol- low set-up and binding instructions. 3. If the binding is successful, the Bluetooth® symbol ( ) will appear on the display and keep flashing during data transfer. The current measured value will automatically be transferred to the App when the measurement is completed. 4. If the binding has failed, the Bluetooth® symbol ( ) will not appear on the display and the current measured value will not automatically be transferred to the App. In this case, the value is saved in the selected user memory zone. Please re-bind this device with your smartphone and follow App instructions for Bluetooth® transfer. APP APP APP APP 120mmHg 120mmHg USB PC BP Manager APP APP APP APP 120mmHg 120mmHg USB PC BP Manager 1. The monitor has two memory zones (1 and 2). Each zone can store up to 60 measure- ments. 2. To read memory values from a selected memory zone, use the User-Switching key to select a memory zone (1 or 2) from which you want to recall values. Press the Memory key. The first reading displayed is the average of all morning readings from the last 7 days. 3. Continue to press the Memory key to view the average of all nighttime readings from the last 7 days. 4. Press the Memory key again to view the average of the last 3 measurements stored in memory, and the last previously stored measurement. Every measurement comes with an assigned memory sequence number. 5. All readings currently saved on the device can be transferred to the App using Blue- tooth® after successful completion of the binding process. Select the desired user memory zone and follow App instructions, the Bluetooth® transfer starts automatically. Data transfer will be halted while performing a measurement or operating the device. Note: The memory bank can store up to 60 readings per memory zone. When the num- ber of readings exceeds 60, the oldest data will be replaced with the new record. Note: AM is defined as 4:00 AM – 11:59 AM Note: PM is defined as 6:00 PM – 2:00 AM 1. Press the User-Switching key to select memory zone 1 or memory zone 2. 2. Press and hold the Memory key for approximately 5 seconds, then the data in the mem- ory zone can be erased automatically. 1. Adjust the date/time/Bluetooth® in the monitor by installing or replacing batteries or holding down the ON/OFF/START key for approximately 5 seconds under power off mode. The display will show a blinking number showing the year. 2. Change the year by pressing the Memory key, each press will increase the number. Press the ON/OFF/START key to confirm the entry and the screen will show a blinking number representing the date. 3. Change the date, the hour and the minute as described in Step 2 above, using the Memory key to change and the ON/OFF/START key to confirm the entries. 4. After adjusting the date/time, the Bluetooth® symbol ( ) and the blinking icon “ ” will be shown on the display simultaneously. Use the Memory key to choose whether automatic Bluetooth® data transfer is activated (Bluetooth® symbol ( )+ ) or de- activated (Bluetooth® symbol ( )+ ) and confirm with the ON/OFF/START key. 5. Press the ON/OFF/START key again, “0” will reappear as the Blood Pressure Monitor is ready for measurement. GMC provides a free, integrated and user-friendly blood pressure management software which can be downloaded and installed on your computer. You may purchase a special designed USB cable in order to connect GMC’s blood pressure monitor and your PC. If any abnormality will arise during use, please check the following points. SymptomsCheck PointsCorrection No display when the ON/OFF/START key is pressed Have the batteries run down?Replace them with four new batteries. Have the batteries' polarities been positioned incorrectly? Re-insert the batteries in the correct positions. EE mark shown on display or the blood pressure value is displayed excessively low (high) Is the cuff placed correctly? Wrap the cuff properly so that it is positioned correctly. Did you talk or move during measurement? Measure again. Keep wrist steady dur- ing measurement. Did you vigorously shake the cuff during measurement? Note: If the unit still does not work, return it to your dealer. Under no circumstance should you disassemble and repair the unit by yourself. 1. The unit contains high-precision assemblies. Therefore, avoid extreme temperatures, humidity, and direct sunlight. Avoid dropping or strongly shocking the main unit, and protect it from dust. 2. Clean the blood pressure monitor body and the cuff carefully with a slightly damp, soft cloth. Do not press. Do not wash the cuff or use chemical cleaner on it. Never use thinner, alcohol or petrol (gasoline) as cleaner. 3. Leaky batteries can damage the unit. Remove the batteries when the unit is not used for a long time. 4. The unit should not be operated by children so to avoid hazardous situations. 5. If the unit is stored near freezing, allow it to acclimate at room temperature before use. 6. This unit is not field serviceable. You should not use any tool to open the device nor should you at- tempt to adjust anything inside the device. If you have any problems, please contact the store or the doctor from whom you purchased this unit or please contact GMC Inc. 7. As a common issue for all blood pressure monitors using the oscillometric measurement function, the device may have difficulty in determining the proper blood pressure for users diagnosed with diabetes, poor circulation of blood, kidney problems, or for users suffered from stroke, or for uncon- scious users. 8. This unit is able to detect common arrhythmia (atrial or ventricular premature beats or atrial fibrilla- tion). T…
Text truncated - open the document above for the full version.
EUT Photo No.: E2/2020/80001~2-P Page: 1 of 8 Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only. 除非另有說明,此報告結果僅對測試之樣品負責,同時此樣品僅保留90天。本報告未經本公司書面許可,不可部份複製。 This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible athttp://www.sgs.com.tw/Terms-and-Conditionsand for electronic format documents, subject to Terms and Conditions for Electronic Documents athttp://www.sgs.com.tw/Terms-and-Conditions. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon ref lects the Company’s findings at the time of its intervention only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. This document cannot be reproduced except in f ull, without prior written approval of the Company. Any unauthorized alteration, forgery or f alsif ication of the content or appearance of this document is unlawf ul and offenders may be prosecuted to the fullest extent of the law. SGS Taiwan Ltd.No.134,Wu Kung Road, New Taipei Industrial Park, Wuku District, New Taipei City, Taiwan/新北市五股區新北產業園區五工路134 號 台灣檢驗科技股份有限公司t (886-2) 2299-3279f (886-2) 2298-0488www.sgs.com.tw Member of SGS Group EXTERNAL PHOTOGRAPHS OF EUT All View of EUT (Model No.: X5) Front View of EUT EUT Photo No.: E2/2020/80001~2-P Page: 2 of 8 Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only. 除非另有說明,此報告結果僅對測試之樣品負責,同時此樣品僅保留90天。本報告未經本公司書面許可,不可部份複製。 This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible athttp://www.sgs.com.tw/Terms-and-Conditionsand for electronic format documents, subject to Terms and Conditions for Electronic Documents athttp://www.sgs.com.tw/Terms-and-Conditions. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon ref lects the Company’s findings at the time of its intervention only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. This document cannot be reproduced except in f ull, without prior written approval of the Company. Any unauthorized alteration, forgery or f alsif ication of the content or appearance of this document is unlawf ul and offenders may be prosecuted to the fullest extent of the law. SGS Taiwan Ltd.No.134,Wu Kung Road, New Taipei Industrial Park, Wuku District, New Taipei City, Taiwan/新北市五股區新北產業園區五工路134 號 台灣檢驗科技股份有限公司t (886-2) 2299-3279f (886-2) 2298-0488www.sgs.com.tw Member of SGS Group Back View of EUT Side View of EUT – 1 EUT Photo No.: E2/2020/80001~2-P Page: 3 of 8 Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only. 除非另有說明,此報告結果僅對測試之樣品負責,同時此樣品僅保留90天。本報告未經本公司書面許可,不可部份複製。 This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible athttp://www.sgs.com.tw/Terms-and-Conditionsand for electronic format documents, subject to Terms and Conditions for Electronic Documents athttp://www.sgs.com.tw/Terms-and-Conditions. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon ref lects the Company’s findings at the time of its intervention only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. This document cannot be reproduced except in f ull, without prior written approval of the Company. Any unauthorized alteration, forgery or f alsif ication of the content or appearance of this document is unlawf ul and offenders may be prosecuted to the fullest extent of the law. SGS Taiwan Ltd.No.134,Wu Kung Road, New Taipei Industrial Park, Wuku District, New Taipei City, Taiwan/新北市五股區新北產業園區五工路134 號 台灣檢驗科技股份有限公司t (886-2) 2299-3279f (886-2) 2298-0488www.sgs.com.tw Member of SGS Group Side View of EUT – 2 Side View of EUT – 3 EUT Photo No.: E2/2020/80001~2-P Page: 4 of 8 Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only. 除非另有說明,此報告結果僅對測試之樣品負責,同時此樣品僅保留90天。本報告未經本公司書面許可,不可部份複製。 This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible athttp://www.sgs.com.tw/Terms-and-Conditionsand for electronic format documents, subject to Terms and Conditions for Electronic Documents athttp://www.sgs.com.tw/Terms-and-Conditions. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon ref lects the Company’s findings at the time of its intervention only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. This document cannot be reproduced except in f ull, without prior written approval of the C…
Text truncated - open the document above for the full version.
Label & Location The label stick on the Back View FCC ID: 2AWWDNA17
EUT Photo No.: E2/2020/80001~2-P Page: 1 of 7 Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only. 除非另有說明,此報告結果僅對測試之樣品負責,同時此樣品僅保留90天。本報告未經本公司書面許可,不可部份複製。 This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible athttp://www.sgs.com.tw/Terms-and-Conditionsand for electronic format documents, subject to Terms and Conditions for Electronic Documents athttp://www.sgs.com.tw/Terms-and-Conditions. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon ref lects the Company’s findings at the time of its intervention only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. This document cannot be reproduced except in f ull, without prior written approval of the Company. Any unauthorized alteration, forgery or f alsif ication of the content or appearance of this document is unlawf ul and offenders may be prosecuted to the fullest extent of the law. SGS Taiwan Ltd.No.134,Wu Kung Road, New Taipei Industrial Park, Wuku District, New Taipei City, Taiwan/新北市五股區新北產業園區五工路134 號 台灣檢驗科技股份有限公司t (886-2) 2299-3279f (886-2) 2298-0488www.sgs.com.tw Member of SGS Group INTERNAL PHOTOGRAPHS OF EUT Open View of EUT – 1 (Model No.: X5) Open View of EUT – 2 EUT Photo No.: E2/2020/80001~2-P Page: 2 of 7 Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only. 除非另有說明,此報告結果僅對測試之樣品負責,同時此樣品僅保留90天。本報告未經本公司書面許可,不可部份複製。 This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible athttp://www.sgs.com.tw/Terms-and-Conditionsand for electronic format documents, subject to Terms and Conditions for Electronic Documents athttp://www.sgs.com.tw/Terms-and-Conditions. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon ref lects the Company’s findings at the time of its intervention only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. This document cannot be reproduced except in f ull, without prior written approval of the Company. Any unauthorized alteration, forgery or f alsif ication of the content or appearance of this document is unlawf ul and offenders may be prosecuted to the fullest extent of the law. SGS Taiwan Ltd.No.134,Wu Kung Road, New Taipei Industrial Park, Wuku District, New Taipei City, Taiwan/新北市五股區新北產業園區五工路134 號 台灣檢驗科技股份有限公司t (886-2) 2299-3279f (886-2) 2298-0488www.sgs.com.tw Member of SGS Group Open View of EUT – 3 Internal View of EUT – 1 EUT Photo No.: E2/2020/80001~2-P Page: 3 of 7 Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only. 除非另有說明,此報告結果僅對測試之樣品負責,同時此樣品僅保留90天。本報告未經本公司書面許可,不可部份複製。 This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible athttp://www.sgs.com.tw/Terms-and-Conditionsand for electronic format documents, subject to Terms and Conditions for Electronic Documents athttp://www.sgs.com.tw/Terms-and-Conditions. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon ref lects the Company’s findings at the time of its intervention only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. This document cannot be reproduced except in f ull, without prior written approval of the Company. Any unauthorized alteration, forgery or f alsif ication of the content or appearance of this document is unlawf ul and offenders may be prosecuted to the fullest extent of the law. SGS Taiwan Ltd.No.134,Wu Kung Road, New Taipei Industrial Park, Wuku District, New Taipei City, Taiwan/新北市五股區新北產業園區五工路134 號 台灣檢驗科技股份有限公司t (886-2) 2299-3279f (886-2) 2298-0488www.sgs.com.tw Member of SGS Group Internal View of EUT – 2 Internal View of EUT – 3 EUT Photo No.: E2/2020/80001~2-P Page: 4 of 7 Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only. 除非另有說明,此報告結果僅對測試之樣品負責,同時此樣品僅保留90天。本報告未經本公司書面許可,不可部份複製。 This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible athttp://www.sgs.com.tw/Terms-and-Conditionsand for electronic format documents, subject to Terms and Conditions for Electronic Documents athttp://www.sgs.com.tw/Terms-and-Conditions. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon ref lects the Company’s findings at the time of its intervention only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. This document cannot be reproduced except in f ull, without prior w…
Text truncated - open the document above for the full version.
Report No: E2/2020/80002 Page:1 of 6 Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only. 除非另有說明, 此報告結果僅對測試之樣品負責, 同時此樣品僅保留90天。 本報告未經本公司書面許可, 不可部份複製。 This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and for electronic format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon ref lects the Company’s findings at the time of its intervention only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerateparties to a transaction from exercising all their rights and obligations under the transaction documents. This document cannot be reproduced except in f ull, without prior written approval of the Company. Any unauthorized alteration, forgery orf alsification of the content or appearance of this document is unlawf ul and offenders may beprosecuted to thef ullest extent of the law. SGS Taiwan Ltd.No.134,Wu Kung Road, New Taipei Industrial Park, Wuku District, New Taipei City, Taiwan/新北市五股區新北產業園區五工路134 號 台灣檢驗科技股份有限公司t (886-2) 2299-3279f (886-2) 2298-0488www.tw.sgs.com Member of SGS Group RF EXPOSURE REPORT OF Applicant:GMC Inc. No.686 Su Chu RD., Chuzhou ,Anhui, China Product Name:Blood pressure monitor Brand Name:N/A Model No.:X5 BT, X3 BT Model Difference:Difference in exterior appearance Report Number:E2/2020/80002 FCC ID2AWWDNA17 FCC Rule PartPart 2.1093 Issue Date:Aug. 28, 2020 We hereby certify that: The data evaluation in this report is in compliance with FCC Rules Part 2. The results of this report relate only to the sample identified in this report. Approved By: John Yeh/ Asst. Manager Report No: E2/2020/80002 Page:2 of 6 Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only. 除非另有說明, 此報告結果僅對測試之樣品負責, 同時此樣品僅保留90天。 本報告未經本公司書面許可, 不可部份複製。 This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and for electronic format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon ref lects the Company’s findings at the time of its intervention only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerateparties to a transaction from exercising all their rights and obligations under the transaction documents. This document cannot be reproduced except in f ull, without prior written approval of the Company. Any unauthorized alteration, forgery orf alsification of the content or appearance of this document is unlawf ul and offenders may beprosecuted to thef ullest extent of the law. SGS Taiwan Ltd.No.134,Wu Kung Road, New Taipei Industrial Park, Wuku District, New Taipei City, Taiwan/新北市五股區新北產業園區五工路134 號 台灣檢驗科技股份有限公司t (886-2) 2299-3279f (886-2) 2298-0488www.tw.sgs.com Member of SGS Group Revision History Report NumberRevisionDescriptionIssue DateRemark E2/2020/80002Rev.00Original.Aug. 28, 2020Revised By: Elle Chang Note: 1.Multiple Model numbers or Trademarks The variant model numbers are assessed as identical in hardware and software to each other, hence all variants are fully covered by the test results in this test report without further verification test. 2.Disclaimer Variant information between model numbers is provided by the applicant, test results of this report are applicable to the sample EUT received. Report No: E2/2020/80002 Page:3 of 6 Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only. 除非另有說明, 此報告結果僅對測試之樣品負責, 同時此樣品僅保留90天。 本報告未經本公司書面許可, 不可部份複製。 This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and for electronic format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon ref lects the Company’s findings at the time of its intervention only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerateparties to a transaction from exercising all their rights and obligations under the transaction documents. This document cannot be reproduced except in f ull, without prior written approval of the Company. Any unauthorized alteration, forgery orf alsification of the content or appearance of this document is unlawf ul and offenders may beprosecuted to thef ullest extent of the law. SGS Taiwan Ltd.No.134,Wu Kung Road, New Taipei Industrial Park, Wuku District, New Taipei City, Taiwan/新北市五股區新北產業園區五工路134 號 台灣檢驗科技股份有限公司t (886-2) 2299-3279f (886-2) 2298-0488www.tw.sgs.com Member of SGS Group 1 DESCRIPTION OF EQUIPMENT UNDER TEST (EUT) 1.1General Information Product Name:Blood pressure monitor Brand Name:N/A Model No.:X5 BT, X3 BT Model Difference:Difference in exterior appearance Hardware Version:N/A Software Version:N/A Power Supply: 6Vdc from AC/DC Ada…
Text truncated - open the document above for the full version.
No. 134, Wu Kung Rd., New Taipei Industrial Park · New Taipei City · Taiwan
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 1.70 mW |

Infrared Temple Thermometer
Equipment Class
DTS - Digital Transmission System