FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. QIKCONNEX D/B/A HAE INNOVATIONS/
  3. 2AX52-LRSM0009BG77

2AX52-LRSM0009BG77Remote AC Relay

QIKCONNEX D/B/A HAE INNOVATIONS
Remote AC Relay - FCC ID 2AX52-LRSM0009BG77 - QIKCONNEX D/B/A HAE INNOVATIONS
Click to zoom

Application Details

Equipment Class
JAB - Part 15 Class B Digital Device
Date of Grant
Jul 06, 2023
Application Purpose
Original Equipment
Date of Application
Jul 06, 2023
Equipment Note
Remote AC Relay
Company
QIKCONNEX D/B/A HAE INNOVATIONS
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Wireless Relay INSTALLATION MANUAL Preface Please read this manual before installing. Any questions, please contact our customer service. 1. Plug appliance into Wireless Relay AC inlet 2. Fit appliance cable inside a grommet 3. Secure the top & bottom cover together 4. Secure Appliance clip 5. Insert AC Input Cable Assembly This Manufacturer advises that all unsecured AC chords be secured against accidental pull by clamping down A and to the REAR PANEL of the appliance. Technical Specifications Electrical Rating Maximum Load Input: 120-240VAC, 15A , 50-60Hz Output: 120-240VAC, 15A , 50-60Hz Operating Temperature 4⁰F to 120⁰F (-20⁰C-50⁰C) Waterproof Rating IP64 Relay Rating 100K open/close events This device complies with part 15 of the FCC Rules. Operation issubject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may causeundesired operation. This Device has been tested and found to comply with the limitsfor a Class B digital device, pursuant to part 15 of the FCC Rules.These limits are designed to provide reasonable protectionagainst harmful interference in a residential installation. ThisDevice generates, uses and can radiate radio frequency energyand, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee thatinterference will not occur in a particular installation. If thisequipment does cause harmful interference to radio ortelevision reception, which can be determined by turning theequipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:—Reorient or relocate the receiving antenna. —Increase the separation between the equipment and receiver. —Connect the equipment into an outlet on a circuit differentfrom that to which the receiver is connected. —Consult the dealer or an experienced radio/TV technician forhelp. Warning: Any changes or modification not expressly approvedby the party responsible for compliance could void the user'sauthority to operate the Device. RF Exposure Information This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator and your body. Appliance Rear View B A Water Inlets C Front View IMPORTANT: DEVICE PLACEMENT 1)Place device as far as possible from water inlets 2)Place device as close to the top of the appliance as possible (above water inlets where possible). 3)Place with AC power facing the floor to avoid hazardous conditions (water exposure from top) Figure A AB 6. Attach Wireless Relay onto REAR PANEL of appliance [Figure A] 7. Test Wireless connection -See Test Application Manual Example

Attestation Statements

- QIKCONNEX D/B/A HAE INNOVATIONS - The information provided in this letter is based on the referenced rule parts of Title 47 of the CFR as well as KDB 986446 D01. An expiration date for this letter does not exist. In case the U.S. agent changes, the grantee is obligated to notify the FCC within 30 days via the granting TCB. Federal Communications Commission Authorization and Evaluation Division Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MD 21046 5/6/2023 U.S. Agent Designation QIKCONNEX D/B/A HAE INNOVATIONS acknowledges their consent for the following contact located in the United States to act as their agent for service of process for the equipment for which authorization is sought (FCC ID: 2AX52-LRSM0009BG77): Contact Name: Hesham ElHamahmy Company of U.S. agent: QIKCONNEX D/B/A HAE INNOVATIONS Physical U.S. address of agent: 14 CULNEN DR LOWER LEVEL BRANCHBURG New Jersey 08876 United States FRN of U.S. agent: 0030178586 Email address of U.S. agent: [email protected] QIKCONNEX D/B/A HAE INNOVATIONS acknowledges their obligation to accept service of process on behalf of QIKCONNEX D/B/A HAE INNOVATIONS. QIKCONNEX D/B/A HAE INNOVATIONS with the FRN 0030178586 accepts its obligation to maintain an agent for service of process in the United States for no less than one year after either the grantee has permanently terminated all marketing and importation of the applicable equipment within the U.S., or the conclusion of any Commission-related administrative or judicial proceeding involving the equipment, whichever is later. By signing this form, we confirm the above and that we are aware of the application requirements listed under § 2.911(d)(7). Sincerely, Signature Hesham ElHamahmy CEO QIKCONNEX D/B/A HAE INNOVATIONS Signature Hesham ElHamahmy CEO QIKCONNEX D/B/A HAE INNOVATIONS 48_ [mo del] US_Agent_2.911(d)(7) - U, V04

Attestation Statements

C5266091_X24_Ed.2 1/1 QIKCONNEX D/B/A HAE INNOVATIONS “Attestation Statements” TO: Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 The Commission adopted rules that prohibit equipment authorization for “covered” telecommunications equipment and video surveillance equipment produced by entities identified on the Commission’s Covered List 1 , which is periodically updated. See the Covered List for more details. This Attestation Statement is to confirm that we follow the Section 2.911(d)(5)(i)-(ii) Applicant Company name: QIKCONNEX D/B/A HAE INNOVATIONS Grantee code: 2AX52 FCC ID: 2AX52-LRSM0009BG77 Contact Name: Hesham ElHamahmy Address: 14 CULNEN DR LOWER LEVEL BRANCHBURG New Jersey 08876 United States Telephone No: 17322459447 Fax No: 8006508059 Email: [email protected] i. [QIKCONNEX D/B/A HAE INNOVATIONS] (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. The applicant must sign this certification. ii. [QIKCONNEX D/B/A HAE INNOVATIONS] (“the applicant”) certifies that, as of the date of the filing of the application, the applicant [is not] (as a specifically named entity or any of its subsidiaries or affiliates) identified on the Covered List as an entity producing “covered” equipment. The applicant must sign this certification. [QIKCONNEX D/B/A HAE INNOVATIONS] (“the applicant”) certifies that, as of the date of the filing of the application, the applicant [is not] identified on the Covered List as an entity producing “covered” equipment. Date: 2023/05/06 Applicant’s Name: Hesham ElHamahmy Title: CEO Signature 1 The Commission’s Covered List is published by the Public Safety and Homeland Security Bureau and posted on the Commission’s website. This Covered List, which is periodically updated, identifies particular equipment, produced by particular entities, that constitutes “covered” equipment. https://www.fcc.gov/supplychain/coveredlist

Cover Letter(s)

C5266091_X8_Ed.1 1/1 QIKCONNEX D/B/A HAE INNOVATIONS Letter of Authorization Company: QIKCONNEX D/B/A HAE INNOVATIONS Address: 14 CULNEN DR LOWER LEVEL BRANCHBURG New Jersey 08876 United States Product Name: Remote AC Relay Model Number: LRSM0009C FCC Identifier: 2AX52-LRSM0009BG77 We authorize LGAI Technological Center S.A., Ronda de la Font del Carme, s/n, 08193 Bellaterra, Spain, to act on our behalf on all matters concerning the above named equipment. Any individual within LGAI Technological Center S.A. is authorized to act on our behalf and take action on the application. We declare that authorize LGAI Technological Center S.A., Ronda de la Font del Carme, s/n, 08193 Bellaterra, Spain, is allowed to forward all information related to the approval project to the Federal Communication Commission and to discuss any issues concerning the approval application. Any and all acts carried out by LGAI Technological Center S.A. on our behalf shall have the same effect as acts of our own. Name: Hesham ElHamahmy Date: 2023.05.06 Title: CEO Signature of applicant:

Cover Letter(s)

C5266091_X10_Ed.2 1/1 QIKCONNEX D/B/A HAE INNOVATIONS Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 Date: 2023-05.06 Subject: Remote AC Relay FCC ID: 2AX52-LRSM0009BG77 To Whom It May Concern, Pursuant to the provisions of Sections 0.457 and 0.459 of Commission's rules (47CFR0.457, 0.459), we are requesting the Commission to withhold the following attachment(s) as confidential document from public disclosure. Exhibits Long-Term Confidentiality Short-Term Confidentiality NOTE 2 ID Label/Location No No Attestation Statement No No External Photos No ☐ Block Diagram ☒ ☐ Schematics ☒ ☐ Test Report No No Test Setup Photos No ☐ User’s Manual ☐ NOTE 1 ☐ Internal Photos ☐ NOTE 1 ☐ Parts List / Tune Up ☐ ☐ RF Exposure Info No No Operational Description ☒ ☐ Cover Letter(s) No No SDR Software / Security Info ☐ No NOTE 1: Long-Term Confidentiality may be permitted under special conditions (See II. LONG-TERM CONFIDENTIALITY, Section 3 of KDB 726920, use last in force) NOTE 2: Short-Term Confidentiality can be requested for a maximum of 180 days from the date of the grant. Above mentioned document contains detailed system and equipment description are considered as proprietary information in operation of the equipment. The public disclosure of above documents might be harmful to our company and would give competitor an unfair advantage in the market. In case of short-term Confidentiality, the applicant requests the exhibits selected above are withheld from public view for a period of ______ days from the date of the Grant of Equipment Authorization and prior to marketing. It is our understanding that all measurement test reports, FCC ID label format and correspondent during certification review process cannot be granted as confidential documents and those information will be available for public review once the grant of equipment authorization is issued. C5266091_X10_Ed.2 1/1 Sincerely, Signature: Name: Hesham ElHamahmy Title: CEO 2023.05.06

External Photos

Page 1 of 3 FCC ID: 2AX52-LRSM0009BG77 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity External Photos of the EUT Fig. 1 Fig. 2 Page 2 of 3 FCC ID: 2AX52-LRSM0009BG77 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 3 Fig. 4 Page 3 of 3 FCC ID: 2AX52-LRSM0009BG77 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 5 Fig. 6

ID Label/Location Info

1 A 2 3 4 5 678 B C D E A B C D E Dept.Technical referenceApproved by Document typeDocument status Created by Hesham ElHamahmy 1/30/2023 50 40 1 0 30 20 1 60 1 8 20 20 74 19.99 10.29 1 TitleDWG No. top cover with labels FF Rev.Date of issueSheet 1/2 12 3 4 5 678 Notes: 1.Dimensions in mm 2.Unless otherwise, stated, text color is BLACK 3.Material: All label materials must comply to UL and/or UL969 standard 4.Marking and labelling system including the label material must comply to UL969 standard Marking and labelling system including the label material must comply to UL969 standard 30 60 60 30 1 A 24 5 678 B C D E A B C D E Dept.Technical referenceApproved by Document typeDocument status Created by Hesham ElHamahmy 1/30/2023 50 40 1 0 30 20 1 60 1 8 20 20 74 19.99 10.29 1 TitleDWG No. top cover with labels FF Rev.Date of issueSheet 2/2 12 3 4 5 678 Notes: 1.Dimensions in mm 112.5 95 30 30 30 5 60 0.1 50 60 Label Location

Internal Photos

Page 1 of 5 FCC ID: 2AX52-LRSM0009BG77 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Internal Photos of the EUT Fig. 1 Fig. 2 Page 2 of 5 FCC ID: 2AX52-LRSM0009BG77 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 3 Fig. 4 Page 3 of 5 FCC ID: 2AX52-LRSM0009BG77 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 5 Fig. 6 Page 4 of 5 FCC ID: 2AX52-LRSM0009BG77 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 7 Fig. 8 Page 5 of 5 FCC ID: 2AX52-LRSM0009BG77 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 9 Antenna

Test Report

Datasheet L-2RS4B 4G LTE/3G/2G ultra-thin FPC Adhesive Antenna The L-2RS4B is a flexible printed circuit (FPC) antenna designed to operate at frequencies ranging from 698 MHz to 2170 MHz, which offers a space-efficient solution for wireless communication applications. One of the key advantages of the L-2RS4B is its customizable connector and cable length options, allowing for seamless integration into various devices and configurations. This flexibility enables easy installation and optimal positioning for improved signal reception. Whether you require a specific connector type or a custom cable length, the L-2RS4B FPC antenna can be tailored to meet your unique requirements. CELLULAR FPC 140.5 x 34.45 x 0.2 mm www.miotsolutions.com [email protected] L-2RS4B | Datasheet 2 Document Information Product L-2RS4B Part Number L-2RS4B Description 4G LTE/3G/2G ultra-thin FPC Adhesive Antenna Version 2.0 (current) Date 30-April-2023 Status Released Revision History Version Date Author Changes 1.0 16-Dec-2020 Amy Li Initial Release 2.0 30-April-2023 Amy Li New layout and design L-2RS4B | Datasheet 3 Product Overview Product Description Key Features The L-2RS4B is a flexible printed circuit (FPC) antenna designed to operate at frequencies ranging from 698 MHz to 2170 MHz, which offers a space-efficient solution for wireless communication applications. One of the key advantages of the L-2RS4B is its customizable connector and cable length options, allowing for seamless integration into various devices and configurations. This flexibility enables easy installation and optimal positioning for improved signal reception. Whether you require a specific connector type or a custom cable length, the L-2RS4B FPC antenna can be tailored to meet your unique requirements. • Supports LTE, LPWA/NB-IoT/Cat-X- Mx-NBx/3G/2G • Wide band Antenna • Adhesive Mount Flexible • Compact Size, Easy to integrate. • RoHS Compliant Applications • Cellular • Transportation • Industrial wearable • Smart city • Home automation • Smart agriculture Electrical Specifications Frequency VSWR Peak Gain Efficiency LTE 698 - 960 MHz 2.2 1.8 d Bi 60% LTE 1710 - 2170 MHz 2.0 3.0 d Bi 60% Frequency Range 698 – 2170 MHz Radiation Omnidirectional Impedance 50 Ω Electrical Type Monopole Polarization Linear L-2RS4B | Datasheet 4 Mechanical Specifications Type FPC Casing NA Dimensions 140.5 x 34.45 x 0.2 mm Color Black Connector (Termination) U.FL (standard) Material Flexible Polymer Cable Type 1.13mm (standard) Cable Length 150mm (standard) Mounting Type Adhesive Weight TBC (to be confirmed) Caution: 1. Do not apply excess mechanical stress to the component body or terminations. Do not attempt to re-form or bend the components, as this will cause damage to the component. 2. Do not expose the component to an open flame. 3. This specification applies to the functionality of the component as a single unit. Please ensure the component is thoroughly evaluated in the application circuit. Product Image and Dimensions L-2RS4B| Datasheet 5 Radiation Pattern A radiation pattern is a graphical representation of the directional properties of an antenna. It shows how electromagnetic waves are distributed in space in relation to the direction of propagation. By understanding the information provided by a radiation pattern, it is possible to optimize the design and performance of an antenna for specific applications. XY Plane (H) 698 – 2170 MHz L-2RS4B| Datasheet 6 YZ Plane (E1) 698 – 2170 MHz YZ Plane (E2) 698 – 2170 MHz L-2RS4B| Datasheet 7 Antenna Smith and VSWR Frequency VSWR Frequency VSWR 699 MHz 2.13 1990 MHz 1.72 760 MHz 2.55 2170 MHz 2.21 1710 MHz 2.10 L-2RS4B| Datasheet 8 Antenna Efficiency and Gain Frequency Efficiency Gain Frequency Efficiency Gain 700 MHz 62% 1.844936 1870 MHz 71% 3.153318 720 MHz 62% 1.316853 1900 MHz 74% 3.695334 740 MHz 56% 1.015964 1930 MHz 75% 3.467248 760 MHz 56% 0.337244 1990 MHz 71% 3.212214 1710 MHz 64% 3.002792 2100 MHz 56% 2.365917 1750 MHz 63% 3.107701 2130 MHz 53% 2.196587 1790 MHz 65% 2.901881 2170 MHz 54% 1.717013 1830 MHz 68% 2.940343 L-2RS4B| Datasheet 9 Environmental Data Operating Temperature -40 ° C to +85 °C IP Rating NA Compliance RoHS Ordering Information Product Variants Part Number Description L-2RS4B 4G LTE/3G/2G ultra-thin FPC Adhesive Antenna L-2RS4B| Datasheet 10 About MIOT Miot Wireless Solutions, headquartered in Suzhou, China, was established in 2017. It has subsidiaries in Canada, the United States, Brazil, and EMEA. MIOT is a professional designer and manufacturer of Antennas and IoT PCBA products, providing turn-key service to customers worldwide. Our talented R&D team has experienced antenna, hardware, and software engineers who can participate in your new project, from something simple like antenna/selection and design, to complete turn-key services, which entails taking your concept and ideas through design, prototyping, debugging, certification, and manufacturing. Miot offers reliable products at reasonable prices with fast delivery times to help you get ahead in the market. Contact MIOT Wireless Solutions Co. Ltd. 120-5800 Ambler Dr, MISSISSAUGA ONTARIO L4W 4J4 Canada Website: www.miotsolutions.com Email: [email protected] The information contained herein is provided “as is” and MOIT assumes no liability for using the information. No warranty, either express or implied, is given, including but not limited to the accuracy, correctness, reliability, and fitness for a particular purpose of the information. This document may be revised by MOIT at any time. MIOT reserves all rights to this document and the information contained herein. Reproduction, use, modification, or disclosure to third parties of this document without express permission is strictly prohibited. Copyright © 2023, MIOT Wireless Solutions Ltd. All Rights Reserved L-2RS4B| Datasheet 11 www.miotsolutions.com

Test Report

Page 1 of 20 FCC ID: 2AX52-LRSM0009BG77 Report No.: LCSA041023090E Shenzhen LCS Compliance Testing Laboratory Ltd. Add: Room 101, 201, Building A and Room 301, Building C, Juji Industrial Park, Yabianxueziwei, Shajing Street, Bao’an District, Shenzhen, Guangdong, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity FCC Part 15, Subpart B, Class B QIKCONNEX D/B/A HAE INNOVATIONS Remote AC Relay Test Model: LRSM0009C Prepared for : QIKCONNEX D/B/A HAE INNOVATIONS Address : 14 CULNEN DR LOWER LEVEL BRANCHBURG New Jersey 08876 United States Prepared by : Shenzhen LCS Compliance Testing Laboratory Ltd. Address : Room 101, 201, Building A and Room 301, Building C, Juji Industrial Park, Yabianxueziwei, Shajing Street, Bao’an District, Shenzhen, Guangdong, China Tel : (+86)755-82591330 Fax : (+86)755-82591332 Web : www.LCS-cert.com Mail : [email protected] Date of receipt of test sample : April 17, 2023 Number of tested samples : 1 Samples number : A041023090 Date of Test : April 17, 2023 ~ May 30, 2023 Date of Report : June 02, 2023 Page 2 of 20 FCC ID: 2AX52-LRSM0009BG77 Report No.: LCSA041023090E Shenzhen LCS Compliance Testing Laboratory Ltd. Add: Room 101, 201, Building A and Room 301, Building C, Juji Industrial Park, Yabianxueziwei, Shajing Street, Bao’an District, Shenzhen, Guangdong, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity FCC Part 15, Subpart B, Class B FCC 47 CFR Part 15 Subpart B, Class B, ANSI C63.4 -2014 Report Reference No. : LCSA041023090E Date Of Issue ......................... : June 02, 2023 Testing Laboratory Name .... : Shenzhen LCS Compliance Testing Laboratory Ltd. Address .................................. : Room 101, 201, Building A and Room 301, Building C, Juji Industrial Park, Yabianxueziwei, Shajing Street, Bao’an District, Shenzhen, Guangdong, China Testing Location/ Procedure ... : Full application of Harmonised standards ■ Partial application of Harmonised standards □ Other standard testing method □ Applicant’s Name : QIKCONNEX D/B/A HAE INNOVATIONS Address .................................. : 14 CULNEN DR LOWER LEVEL BRANCHBURG New Jersey 08876 United States Test Specification Standard ................................. : FCC 47 CFR Part 15 Subpart B, Class B, ANSI C63.4 -2014 Test Report Form No. : LCSEMC-1.0 TRF Originator ........................ : Shenzhen LCS Compliance Testing Laboratory Ltd. Master TRF ............................. : Dated 2011-03 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. All rights reserved. This publication may be reproduced in whole or in part for non-commercial purposes as long as the SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. is acknowledged as copyright owner and source of the material. SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. Test Item Description. .......... : Remote AC Relay Test Model ............................ : LRSM0009C Trade Mark......................... : N/A Ratings ................................... : Please Refer to Page 7 Result ................................... : Positive Compiled by: Supervised by: Approved by: Cindy Nie/ File administrators Baron Wen/ Technique principal Gavin Liang/ Manager Page 3 of 20 FCC ID: 2AX52-LRSM0009BG77 Report No.: LCSA041023090E Shenzhen LCS Compliance Testing Laboratory Ltd. Add: Room 101, 201, Building A and Room 301, Building C, Juji Industrial Park, Yabianxueziwei, Shajing Street, Bao’an District, Shenzhen, Guangdong, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity FCC -- TEST REPORT Test Result according to the standards on page 6: Positive The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test result without the written permission of the test laboratory. Test Report No. : LCSA041023090E June 02, 2023 Date of issue Test Model ........................ : LRSM0009C EUT.................................... : Remote AC Relay Applicant........................... : QIKCONNEX D/B/A HAE INNOVATIONS Address.............................. : 14 CULNEN DR LOWER LEVEL BRANCHBURG New Jersey 08876 United States Telephone.......................... : / Fax..................................... : / Manufacturer..................... : MIOT Address.............................. : Room 2, No.153 north Youyi RD, Zhoushi town, Kunshan city, Jiangsu province, 215300, China. Telephone.......................... : / Fax..................................... : / Factory.............................. : MIOT Address.............................. : Room 2, No.153 north Youyi RD, Zhoushi town, Kunshan city, Jiangsu province, 215300, China. Telephone.......................... : / Fax..................................... : / Page 4 of 20 FCC ID: 2AX52-LRSM0009BG77 Report No.: LCSA041023090E Shenzhen LCS Compliance Testing Laboratory Ltd. Add: Room 101, 201, Building A and Room 301, Building C, Juji Industrial Park, Yabianxueziwei, Shajing Street, Bao’an District, Shenzhen, Guangdong, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Revision History Revision Issue Date Revision content Revised By 000 June 02, 2023 Initial Issue / Page 5 of 20 FCC ID: 2AX52-LRSM0009BG77 Report No.: LCSA041023090E Shenzhen LCS Compliance Testing Laboratory Ltd. Add: Room 101, 201, Building A and Room 301, Building C, Juji Industrial Park, Yabianxueziwei, Shajing Street, Bao’an District, Shenzhen, Guangdong, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity TABLE OF CONTENTS Test Report Description Page 1. SUMMARY OF STANDARDS AND RESULTS ....…

Text truncated - open the document above for the full version.

Test Setup Photos

Page 1 of 2 FCC ID: 2A3US-6AC-2U1C Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Test Setup Photos of the EUT Photo of Power Line Conducted Measurement Photo of Radiated emission Measurement Below 1GHz Page 2 of 2 FCC ID: 2A3US-6AC-2U1C Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Photo of Radiated Measurement Above 1GHz

Contact Information

Applicant

Hesham ElHamahmy
[email protected]17322459447Fax: 8006508059

Technical Contact

Shenzhen LCS Compliance Testing Laboratory Ltd.Gavin Liang
[email protected]0755-82591330

Shenzhen · China

Test Firm

Shenzhen LCS Compliance Testing Laboratory Ltd.Gavin Liang
[email protected]0755-82591330Fax: 0755-82591132

Technical Specifications

#Rule PartsFrequency RangePower Output
115B--
Confidentiality
Long Term

Other Applications from QIKCONNEX D/B/A HAE INNOVATIONS

IoT Wearable Device - FCC ID 2AX52-LRSM0005 - QIKCONNEX D/B/A HAE INNOVATIONS
2AX52-LRSM0005

IoT Wearable Device

Jul 22, 2021

Equipment Class

TNT - Licensed Non-Broadcast Transmitter Worn on Body