FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Zhuhai Hoksi Technology CO.,LTD/
  3. 2AXCA-K620W

2AXCA-K620WK620w Wireless Mechanical Keyboard

Zhuhai Hoksi Technology CO.,LTD
K620w Wireless Mechanical Keyboard - FCC ID 2AXCA-K620W - Zhuhai Hoksi Technology CO.,LTD
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Nov 10, 2022
Application Purpose
Original Equipment
Date of Application
Nov 01, 2022
Equipment Note
K620w Wireless Mechanical Keyboard
Frequency Range
2402.00000000 - 2480.00000000
Company
Zhuhai Hoksi Technology CO.,LTD
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

&DQDGD6WDWHPHQW7KLVGHYLFHFRQWDLQVOLFHQFHH[HPSWWUDQVPLWWHU V UHFHLYHU V  WKDWFRPSO\ ZLWK,QQRYDWLRQ6FLHQFHDQG(FRQRPLF'HYHORSPHQW&DQDGDÿVOLFHQFHH[HPSW566 V 2SHUDWLRQLVVXEMHFWWRWKHIROORZLQJWZRF RQGLWLRQV  7KLVGHYLFHPD\QRWFDXVHLQWHUIHUHQFH  7KLVGHYLFHPXVWDFFHSWDQ\LQWHUIHUHQFHLQFOXGLQJLQWHUIHU HQFH WKDWPD\FDXVHXQGHVLUHGRSHUDWLRQRIWKHGHYLFH/ÿlPHWWHXUUlFHSWHXUH[HPSWGHOLFHQFHFRQWHQXGDQVOHSUlVHQWDSSDUHLOHVWFRQIRUPHDX[&15Gÿ,QQRYDWLRQ6FLHQFHVHW'lYHORSSHPHQWlFRQRPLTXH&DQDGDDSSOLFDEOHVDX[DSSDUHLOVUDGLRH[HPSWVGHOLFHQFH/ÿH[SORLWDWLRQHVWDXWRULVlHDX[GHX[FRQGLWLRQVVXLYDQWHV /ÿDSSDUHLOQHGRLWSDVSURGXLUHGHEURXLOODJH /ÿDSSDUHLOGRLWDFFHSWHUWRXWEURXLOODJHUDGLRlOHFWULTXHVXE LPmPH VLOHEURXLOODJHHVWVXVFHSWLEOHGÿHQFRPSURPHWWUHOHIRQFWLRQ QHPHQW 7KHGHYLFHPHHWVWKHH[HPSWLRQIURPWKHURXWLQHHYDOXDWLRQOLPL WVLQ VHFWLRQRI566DQGFRPSOLDQFHZLWK5665)H[SRVXUH  XVHUVFDQREWDLQ&DQDGLDQLQIRUPDWLRQRQ5)H[SRVXUHDQGFRPSO LDQFH /HGLVSRVLWLIUHQFRQWUHO H[HPSWLRQGHVOLPLWHVFRXUDQWHVG lYD OXDWLRQ GDQVODVHFWLRQGH566HWODFRQIRUPLWliO H[SRVLWLRQ GH566UI XWLOLVDWHXUVSHXWREWHQLUO LQIRUPDWLRQFDQDGLHQQHVXUO H[SRVL WLRQHWODFRQIRUPLWl GHUI +HUHE\=KXKDL+RNVL7HFKQRORJ\&2/7'GHFODUHVWKDWWKHUDGLR  HTXLSPHQWW\SH'85*2'.Z.Z:LUHOHVV0HFKDQLFDO.H\ERDUG DQG ,QILQLWH:LUHOHVV5HFHLYHUDUHLQFRPSOLDQFHZLWK'LUHFWLYH6,1R7KHIXOOWH[WRIWKH8.GHFODUDWLRQRIFRQIRUPLW\ LV DYDLODEOHDWWKHIROORZLQJLQWHUQHWDGGUHVVKWWSZZZGXUJRGF RP

External Photos

Report No.: FCC022022-5381RF1 Page 1 of 8 TIRT-TRF/FCC01-2(E):2021A0 ATTACHMENT PHOTOGRAPHS OF EUT Report No.: FCC022022-5381RF1 Page 2 of 8 TIRT-TRF/FCC01-2(E):2021A0 Report No.: FCC022022-5381RF1 Page 3 of 8 TIRT-TRF/FCC01-2(E):2021A0 Report No.: FCC022022-5381RF1 Page 4 of 8 TIRT-TRF/FCC01-2(E):2021A0 Report No.: FCC022022-5381RF1 Page 5 of 8 TIRT-TRF/FCC01-2(E):2021A0 Report No.: FCC022022-5381RF1 Page 6 of 8 TIRT-TRF/FCC01-2(E):2021A0 Report No.: FCC022022-5381RF1 Page 7 of 8 TIRT-TRF/FCC01-2(E):2021A0 Report No.: FCC022022-5381RF1 Page 8 of 8 TIRT-TRF/FCC01-2(E):2021A0

Internal Photos

Report No.: FCC022022-5381RF1 Page 1 of 9 TIRT-TRF/FCC01-2(E):2021A0 ATTACHMENT PHOTOGRAPHS OF EUT Report No.: FCC022022-5381RF1 Page 2 of 9 TIRT-TRF/FCC01-2(E):2021A0 Report No.: FCC022022-5381RF1 Page 3 of 9 TIRT-TRF/FCC01-2(E):2021A0 Report No.: FCC022022-5381RF1 Page 4 of 9 TIRT-TRF/FCC01-2(E):2021A0 Report No.: FCC022022-5381RF1 Page 5 of 9 TIRT-TRF/FCC01-2(E):2021A0 Report No.: FCC022022-5381RF1 Page 6 of 9 TIRT-TRF/FCC01-2(E):2021A0 Report No.: FCC022022-5381RF1 Page 7 of 9 TIRT-TRF/FCC01-2(E):2021A0 Report No.: FCC022022-5381RF1 Page 8 of 9 TIRT-TRF/FCC01-2(E):2021A0 Report No.: FCC022022-5381RF1 Page 9 of 9 TIRT-TRF/FCC01-2(E):2021A0

RF Exposure Info

Report No.: FCC022022-5381RF14 Page 1 of 6 FCC Radio Test Report FCC ID: 2AXCA-K620W Project No. : 022022-5381 Equipment : K620w Wireless Mechanical Keyboard Brand Name : DURGOD Test Model : K620w Series Model : N/A Applicant : Zhuhai Hoksi Technology CO.,LTD Address : Room803, No.3 BLDG, No.6, Pingbei 1 Rd., Nanping Technology & Industry Park, Xiangzhou St., ZhuHai,China Manufacturer : Zhuhai Hoksi Technology CO.,LTD Address Factory Address : : : Room803, No.3 BLDG, No.6, Pingbei 1 Rd., Nanping Technology & Industry Park, Xiangzhou St., ZhuHai,China Zhuhai Hengcang Electronic Technology Co.,Ltd 3rd floor, A building, No. 7 of 3rd pingxi Road, Nanping Technical industry park, Zhuhai, China Date of Test : 2022.09.05-2022.10.31 Issued Date : 2022.10.31 Report Version : V1.0 Test Sample : 20220513018140 Standard(s) : FCC Guidelines for Human Exposure IEEE C95.1 & KDB447498 D04 The above equipment has been tested and found compliance with the requirement of the relative standards by TIRT Inc. • The test result referred exclusively to the presented test model /sample. • Without written approval of TIRT Inc. the test report shall not reproduced except in full. Add: Plant 3,Gongjindianzi,Shatian, Kengzi Street, Pingshan District, Shenzhen, Guangdong, China TEL: +86-0755-27087573 Prepared by : Stone Tang Approved by : Daniel Chen Report No.: FCC022022-5381RF14 Page 2 of 6 REPORT ISSUED HISTORY Report No. Version Description Issued Date Note FCC022022-5381RF14 V1.0 Original Report. Valid Report No.: FCC022022-5381RF14 Page 3 of 6 1. TEST FACILITY Add: Plant 3,Gongjindianzi,Shatian, Kengzi Street, Pingshan District, Shenzhen, Guangdong, China 2. GENERAL CONCULUSION According to FCC §§1.1307 and KDB 447498 D04, the available maximum time-averaged power or effective radiated power (ERP), whichever is greater, is less than or equal to the threshold P th (mW). 1) Option A. 1-mW Test Exemption Per § 1.1307(b)(3)(i)(A), a single RF source is exempt RF device (from the requirement to show data demonstrating compliance to RF exposure limits, as previously mentioned) if the available maximum time-averaged power is no more than 1 mW, regardless of separation distance. This exemption applies to all operating configurations and exposure conditions, for the frequency range 100 kHz to 100 GHz, regardless of fixed, mobile, or portable device exposure conditions. This is a standalone exemption, and it cannot be applied in conjunction with any other test exemption. 2) Option B. SAR-Based Exemption A more comprehensive exemption, considering a variable power threshold that depends on both the separation distance and power, is provided in § 1.1307(b)(3)(i)(B). This exemption is applicable to the frequency range between 300 MHz and 6 GHz, with test separation distances between 0.5 cm and 40 cm, and for all RF sources in fixed, mobile, and portable device exposure conditions. Accordingly, a RF source is considered an RF exempt device if its available maximum time-averaged (matched conducted) power or its effective radiated power (ERP), whichever is greater, are below a specified threshold. This method shall only be used at separation distances (cm) from 0.5 centimeters to 40 centimeters and at frequencies from 0.3 GHz to 6 GHz (inclusive). Pth is given by: Report No.: FCC022022-5381RF14 Page 4 of 6 Table B2-Example Power Thresholds (mW) Frequency (MHz) Distance(mm) mW 5 10 15 20 25 30 35 40 45 50 300 39 65 88 110 129 148 166 184 201 217 450 22 44 67 89 112 135 158 180 203 226 835 9 25 44 66 90 116 145 175 207 240 1900 3 12 26 44 66 92 122 157 195 236 2450 3 10 22 38 59 83 111 143 179 219 3600 2 8 18 32 49 71 96 125 158 195 5800 1 6 14 25 40 58 80 106 136 169 3) Option C MPE-Based Exemption An alternative to the SAR-based exemption is provided in § 1.1307(b)(3)(i)(C), for a much wider frequency range, from 300 kHz to 100 GHz, applicable for separation distances greater or equal to λ/2π, where λ is the free-space operating wavelength in meters. The MPE-based test exemption condition is in terms of ERP, defined as the product of the maximum antenna gain and the delivered maximum time-averaged power. For this case, a RF source is an RF exempt device if its ERP (watts) is no more than a frequency-dependent value, as detailed tabular form in Appendix B. These limits have been derived based on the basic specifications on Maximum Permissible Exposure (MPE) considered for the FCC rules in § 1.1310(e)(1). Report No.: FCC022022-5381RF14 Page 5 of 6 In the case of fixed RF sources operating in the same time-averaging period, or of multiple mobile or portable RF sources within a device operating in the same time averaging period, if the sum of the fractional contributions to the applicable thresholds is less than or equal to 1 as indicated in the following equation. Where: a = number of fixed, mobile, or portable RF sources claiming exemption using paragraph (b)(3)(i)(B) of this section for Pth, including existing exempt transmitters and those being added. b = number of fixed, mobile, or portable RF sources claiming exemption using paragraph (b)(3)(i)(C) of this section for Threshold ERP, including existing exempt transmitters and those being added. c = number of existing fixed, mobile, or portable RF sources with known evaluation for the specified minimum distance including existing evaluated transmitters. P i = the available maximum time-averaged power or the ERP, whichever is greater, for fixed, mobile, or portable RF source i at a distance between 0.5 cm and 40 cm (inclusive). P th,i = the exemption threshold power (P th ) according to paragraph (b)(3)(i)(B) of this section for fixed, mobile, or portable RF source i. ERP j = the ERP of fixed, mobile, or portable RF source j. ERP th,j = exemption threshold ERP for fixed, mobile, or portable RF source j, at a distance of at least λ/2π according to the applicable formula of paragraph (b)(3)(i)(C) of this section. Evaluated k = the maximum reported SAR or MPE of fixed, mobile, or …

Text truncated - open the document above for the full version.

Test Report

Approval sheet Page 1 of 11 RFPCA430816IMAB301_V01 Apr.2020 PCB ANTENNA 2.4 GHz Working Frequency Halogens Free Product P/N: RFPCA430816IMAB301 Customer: Customer ‘s Part No.: Approval No.: Issue Date: *Contents in this sheet are subject to change without prior notice. Approval sheet Page 2 of 11 RFPCA430816IMAB301_V01 Apr.2020 Version Date Description Author V01 2020 Apr. New Release SHLEE Approval sheet Page 3 of 11 RFPCA430816IMAB301_V01 Apr.2020 ELECTRICAL CHARACTERISTICS Item Specification Working Frequency Range 2.4 ~ 2.5 GHz(Note-1) Return Loss -10 dB(Max) Gain(peak) 3.12 dBi VSWR < 2.0 Impedance 50 Ohm Nominal Radiation Omni-directional Polarization Linear Vertical Operation Temperature -20°C ~ +65°C *Note 1. Central Frequency should be defined after customers’ application approval. MATERIAL TABLE Items Description Antenna PCB FR4 T=0.6mm(黑漆板) Cable Ø1.13 Cable (Black) Connector IPEX Compatible(Gold) Double Tape 3M9888T ORDERING RULE RF PCA 4308 16 I M A B 3 01 Type Code Product Code PCB Dimension (Unit: mm) Cable Length (unit: cm) Connector Brand Type of Connector Application Project status Wire Diameter Project Walsin RF Device PCB Antenna Per 2 digits of length, width e.g.: 4308 Length 43mm, Width 8.5mm 2 digits for cable length e.g.: 16 Length 16cm A: N C:MCX D:IPEX III E: IPEX IV F: IPEX A13 H: Hirose I: IPEX M: MMCX S: SMA T: TNC U:MURATA N: None A: Reverse Female B: Reverse Male F: Female M: Male N: None 0: 0GHz 3: 3GHz 5: 5GHz 6: 6GHz A: 2.4GHz ISM band B: GSM 900/1800 dual band G: GPS band L: 2.4/5.2/5.8 GHz tri-band N: NFC T: LTE band W: WCDMA band B: MP T:During Test X: Pile Run 0:None 1:∅0.81 2:∅1.32 3:∅1.13 4:Low Loss ∅1.13 5:∅0.5 6:RG316 7: ∅1.37 8:RG178 9:Low Loss ∅1.37 01~99 series number Approval sheet Page 4 of 11 RFPCA430816IMAB301_V01 Apr.2020 Dimensions Approval sheet Page 5 of 11 RFPCA430816IMAB301_V01 Apr.2020 Test Report ■ Experimental Setup Approval sheet Page 6 of 11 RFPCA430816IMAB301_V01 Apr.2020 Approval sheet Page 7 of 11 RFPCA430816IMAB301_V01 Apr.2020 ■ELECTRICAL CHARACTERISTICS Return Loss Approval sheet Page 8 of 11 RFPCA430816IMAB301_V01 Apr.2020 ■Antenna Efficiency & Peak Gain 2400~2500 MHz Approval sheet Page 9 of 11 RFPCA430816IMAB301_V01 Apr.2020 ■RADIATION PATTERN 2400~2500 MHz Phi=0.00deg Gain . dB Approval sheet Page 10 of 11 RFPCA430816IMAB301_V01 Apr.2020 Phi=90.00deg Gain . dB Approval sheet Page 11 of 11 RFPCA430816IMAB301_V01 Apr.2020 Theta=90.00deg Gain . dB

Test Report

Report No.: FCC022022-5381RF5 Page 1 of 46 TIRT-TRF/FCC01-2(E):2021A0 Product Name: K620w Wireless Mechanical Keyboard Report No: FCC022022-5381RF5 Product Model: K620w Security Classification: Open Version: V1.0 Total Page:46 TIRT Testing Report Prepared By: Checked By: Approved By: Stone Tang Randy Lv Daniel Chen Report No.: FCC022022-5381RF5 Page 2 of 46 TIRT-TRF/FCC01-2(E):2021A0 FCC Radio Test Report FCC ID: 2AXCA-K620W This report concerns: Original Grant Project No. : 022022-5381 Equipment : K620w Wireless Mechanical Keyboard Brand Name : DURGOD Test Model : K620w Series Model : N/A Applicant : Zhuhai Hoksi Technology CO.,LTD Address : Room803, No.3 BLDG, No.6, Pingbei 1 Rd., Nanping Technology & Industry Park, Xiangzhou St., ZhuHai,China Manufacturer : Zhuhai Hoksi Technology CO.,LTD Address Factory Address : : : Room803, No.3 BLDG, No.6, Pingbei 1 Rd., Nanping Technology & Industry Park, Xiangzhou St., ZhuHai,China Zhuhai Hengcang Electronic Technology Co.,Ltd 3rd floor, A building, No. 7 of 3rd pingxi Road, Nanping Technical industry park, Zhuhai, China Date of Test : 2022.09.05-2022.10.19 Issued Date : 2022.10.20 Report Version : V1.0 Test Sample : Engineering Sample No.: 20220513018140 Standard(s) : FCC CFR Title 47, Part 15, Subpart C FCC KDB 558074 D01 15.247 Meas Guidance v05r02 ANSI C63.10-2013 • The test result referred exclusively to the presented test model /sample. • Without written approval of TIRT Inc. the test report shall not reproduced except in full. Add: Plant 3,Gongjindianzi,Shatian, Kengzi Street, Pingshan District, Shenzhen, Guangdong, China TEL: +86-0755-27087573 Report No.: FCC022022-5381RF5 Page 3 of 46 TIRT-TRF/FCC01-2(E):2021A0 Table of Contents Page REPORT ISSUED HISTORY 6 1 . SUMMARY OF TEST RESULTS 7 1.1 TEST LOCATION 8 1.2 MEASUREMENT UNCERTAINTY 8 1.3 TEST ENVIRONMENT CONDITIONS 9 2 . GENERAL INFORMATION 10 2.1 GENERAL DESCRIPTION OF EUT 10 2.2 DESCRIPTION OF TEST MODES 11 2.3 PARAMETERS OF TEST SOFTWARE 12 2.4 BLOCK DIAGRAM SHOWING THE CONFIGURATION OF SYSTEM TESTED 12 2.5 SUPPORT UNITS 12 3 . AC POWER LINE CONDUCTED EMISSIONS 13 3.1 LIMIT 13 3.2 TEST PROCEDURE 13 3.3 DEVIATION FROM TEST STANDARD 13 3.4 TEST SETUP 14 3.5 EUT OPERATION CONDITIONS 14 3.6 TEST RESULTS 14 4 . RADIATED EMISSIONS 15 4.1 LIMIT 15 4.2 TEST PROCEDURE 16 4.3 DEVIATION FROM TEST STANDARD 17 4.4 TEST SETUP 17 4.5 EUT OPERATION CONDITIONS 18 4.6 TEST RESULTS - 9 KHZ TO 30 MHZ 18 4.7 TEST RESULTS - 30 MHZ TO 1000 MHZ 18 4.8 TEST RESULTS - ABOVE 1000 MHZ 18 5 . BANDWIDTH 19 5.1 LIMIT 19 5.2 TEST PROCEDURE 19 5.3 DEVIATION FROM STANDARD 19 5.4 TEST SETUP 19 5.5 EUT OPERATION CONDITIONS 19 Report No.: FCC022022-5381RF5 Page 4 of 46 TIRT-TRF/FCC01-2(E):2021A0 Table of Contents Page 5.6 TEST RESULTS 19 6 . MAXIMUM OUTPUT POWER 20 6.1 LIMIT 20 6.2 TEST PROCEDURE 20 6.3 DEVIATION FROM STANDARD 20 6.4 TEST SETUP 20 6.5 EUT OPERATION CONDITIONS 20 6.6 TEST RESULTS 20 7 . CONDUCTED SPURIOUS EMISSIONS 21 7.1 LIMIT 21 7.2 TEST PROCEDURE 21 7.3 DEVIATION FROM STANDARD 21 7.4 TEST SETUP 21 7.5 EUT OPERATION CONDITIONS 21 7.6 TEST RESULTS 21 8 . POWER SPECTRAL DENSITY 22 8.1 LIMIT 22 8.2 TEST PROCEDURE 22 8.3 DEVIATION FROM STANDARD 22 8.4 TEST SETUP 22 8.5 EUT OPERATION CONDITIONS 22 8.6 TEST RESULTS 22 9 . MEASUREMENT INSTRUMENTS LIST 23 10 . EUT TEST PHOTO 24 APPENDIX A - AC POWER LINE CONDUCTED EMISSIONS 26 APPENDIX B - RADIATED EMISSION - 9 KHZ TO 30 MHZ 29 APPENDIX C - RADIATED EMISSION - 30 MHZ TO 1000 MHZ 30 APPENDIX D - RADIATED EMISSION- ABOVE 1000 MHZ 33 APPENDIX E - BANDWIDTH 39 APPENDIX F - MAXIMUM AVERAGE OUTPUT POWER 41 APPENDIX G - CONDUCTED SPURIOUS EMISSIONS 43 APPENDIX H - POWER SPECTRAL DENSITY 45 Report No.: FCC022022-5381RF5 Page 5 of 46 TIRT-TRF/FCC01-2(E):2021A0 Table of Contents Page Report No.: FCC022022-5381RF5 Page 6 of 46 TIRT-TRF/FCC01-2(E):2021A0 REPORT ISSUED HISTORY Report No. Version Description Issued Date Note FCC022022-5381RF5 V1.0 Original Report. 2022.10.20 Valid Report No.: FCC022022-5381RF5 Page 7 of 46 TIRT-TRF/FCC01-2(E):2021A0 1. SUMMARY OF TEST RESULTS Test procedures according to the technical standard(s): FCC CFR Title 47, Part 15, Subpart C Standard(s) Section Test Item Test Result Judgment Remark 15.207 AC Power Line Conducted Emissions APPENDIX A PASS ------ 15.247(d) 15.205(a) 15.209(a) Radiated Emissions APPENDIX B APPENDIX C APPENDIX D PASS ------ 15.247(a)(2) Bandwidth APPENDIX E PASS ------ 15.247(b)(3) Maximum Output Power APPENDIX F PASS ------ 15.247(d) Conducted Spurious Emissions APPENDIX G PASS ------ 15.247(e) Power Spectral Density APPENDIX H PASS ------ 15.203 Antenna Requirement ------ PASS Note(2) Note: (1) “N/A” denotes test is not applicable in this test report. (2) The device what use a permanently attached antenna were considered sufficient to comply with the provisions of 15.203. Report No.: FCC022022-5381RF5 Page 8 of 46 TIRT-TRF/FCC01-2(E):2021A0 1.1 TEST LOCATION Company: Beijing TIRT Technology Service Co.,Ltd Shenzhen Address: 101, 3 # Factory Building, Gongjin Electronics Shatin Community, Kengzi Street, Pingshan District, Shenzhen, China CNAS Registration Number: CNAS L14158 A2LA Registration Number: 6049.01 FCC Accredited Lab. Designation Number: CN1309 FCC Test Firm Registration Number: 825524 Telephone: +86-0755-27087573 1.2 MEASUREMENT UNCERTAINTY ISO/IEC 17025 requires that an estimate of the measurement uncertainties associated with the emissions test results be included in the report. The measurement uncertainties given below are based on a 95% confidence level (based on a coverage factor (k=2)) The TIRT measurement uncertainty as below table: Uncertainty Parameter Uncertainty Occupied Channel Bandwidth ±142.12kHz RF power conducted ±0.74dB RF power radiated ±3.25dB Spurious emissions, conducted ±1.78dB Spurious emissions, radiated (30MHz~1GHz) ±4.6dB Spurious emissions, radiated (1GHz ~ 18GHz) ±4.9dB Conduction Emissions(150kHz~30MHz) ±3.1dB Humidity ±4.6% Temperature ±0.7°C Time ±1.25% Note: Unless specific…

Text truncated - open the document above for the full version.

Test Report

Report No.: FCC022022-5381RF0 Page 1 of 46 TIRT-TRF/FCC01-2(E):2021A0 Product Name: K620w Wireless Mechanical Keyboard Report No: FCC022022-5381RF0 Product Model: K620w Security Classification: Open Version: V1.0 Total Page:46 TIRT Testing Report Prepared By: Checked By: Approved By: Stone Tang Randy Lv Daniel Chen Report No.: FCC022022-5381RF0 Page 2 of 46 TIRT-TRF/FCC01-2(E):2021A0 FCC Radio Test Report FCC ID: 2AXCA-K620W This report concerns: Original Grant Project No. : 022022-5381 Equipment : K620w Wireless Mechanical Keyboard Brand Name : DURGOD Test Model : K620w Series Model : N/A Applicant : Zhuhai Hoksi Technology CO.,LTD Address : Room803, No.3 BLDG, No.6, Pingbei 1 Rd., Nanping Technology & Industry Park, Xiangzhou St., ZhuHai,China Manufacturer : Zhuhai Hoksi Technology CO.,LTD Address Factory Address : : : Room803, No.3 BLDG, No.6, Pingbei 1 Rd., Nanping Technology & Industry Park, Xiangzhou St., ZhuHai,China Zhuhai Hengcang Electronic Technology Co.,Ltd 3rd floor, A building, No. 7 of 3rd pingxi Road, Nanping Technical industry park, Zhuhai, China Date of Test : 2022.09.05-2022.10.19 Issued Date : 2022.10.20 Report Version : V1.0 Test Sample : Engineering Sample No.: 20220513018141 Standard(s) : FCC CFR Title 47, Part 15, Subpart C FCC KDB 558074 D01 15.247 Meas Guidance v05r02 ANSI C63.10-2013 • The test result referred exclusively to the presented test model /sample. • Without written approval of TIRT Inc. the test report shall not reproduced except in full. Add: Plant 3,Gongjindianzi,Shatian, Kengzi Street, Pingshan District, Shenzhen, Guangdong, China TEL: +86-0755-27087573 Report No.: FCC022022-5381RF0 Page 3 of 46 TIRT-TRF/FCC01-2(E):2021A0 Table of Contents Page REPORT ISSUED HISTORY 6 1 . SUMMARY OF TEST RESULTS 7 1.1 TEST LOCATION 8 1.2 MEASUREMENT UNCERTAINTY 8 1.3 TEST ENVIRONMENT CONDITIONS 8 2 . GENERAL INFORMATION 9 2.1 GENERAL DESCRIPTION OF EUT 9 2.2 DESCRIPTION OF TEST MODES 10 2.3 PARAMETERS OF TEST SOFTWARE 11 2.4 BLOCK DIAGRAM SHOWING THE CONFIGURATION OF SYSTEM TESTED 11 2.5 SUPPORT UNITS 12 3 . AC POWER LINE CONDUCTED EMISSIONS 13 3.1 LIMIT 13 3.2 TEST PROCEDURE 13 3.3 DEVIATION FROM TEST STANDARD 13 3.4 TEST SETUP 14 3.5 EUT OPERATION CONDITIONS 14 3.6 TEST RESULTS 14 4 . RADIATED EMISSIONS 15 4.1 LIMIT 15 4.2 TEST PROCEDURE 16 4.3 DEVIATION FROM TEST STANDARD 17 4.4 TEST SETUP 17 4.5 EUT OPERATION CONDITIONS 18 4.6 TEST RESULTS - 9 KHZ TO 30 MHZ 18 4.7 TEST RESULTS - 30 MHZ TO 1000 MHZ 18 4.8 TEST RESULTS - ABOVE 1000 MHZ 18 5 . BANDWIDTH 19 5.1 LIMIT 19 5.2 TEST PROCEDURE 19 5.3 DEVIATION FROM STANDARD 19 5.4 TEST SETUP 19 5.5 EUT OPERATION CONDITIONS 19 Report No.: FCC022022-5381RF0 Page 4 of 46 TIRT-TRF/FCC01-2(E):2021A0 Table of Contents Page 5.6 TEST RESULTS 19 6 . MAXIMUM OUTPUT POWER 20 6.1 LIMIT 20 6.2 TEST PROCEDURE 20 6.3 DEVIATION FROM STANDARD 20 6.4 TEST SETUP 20 6.5 EUT OPERATION CONDITIONS 20 6.6 TEST RESULTS 20 7 . CONDUCTED SPURIOUS EMISSIONS 21 7.1 LIMIT 21 7.2 TEST PROCEDURE 21 7.3 DEVIATION FROM STANDARD 21 7.4 TEST SETUP 21 7.5 EUT OPERATION CONDITIONS 21 7.6 TEST RESULTS 21 8 . POWER SPECTRAL DENSITY 22 8.1 LIMIT 22 8.2 TEST PROCEDURE 22 8.3 DEVIATION FROM STANDARD 22 8.4 TEST SETUP 22 8.5 EUT OPERATION CONDITIONS 22 8.6 TEST RESULTS 22 9 . MEASUREMENT INSTRUMENTS LIST 23 10 . EUT TEST PHOTO 24 APPENDIX A - AC POWER LINE CONDUCTED EMISSIONS 26 APPENDIX B - RADIATED EMISSION - 9 KHZ TO 30 MHZ 29 APPENDIX C - RADIATED EMISSION - 30 MHZ TO 1000 MHZ 30 APPENDIX D - RADIATED EMISSION- ABOVE 1000 MHZ 33 APPENDIX E - BANDWIDTH 39 APPENDIX F - MAXIMUM AVERAGE OUTPUT POWER 41 APPENDIX G - CONDUCTED SPURIOUS EMISSIONS 43 APPENDIX H - POWER SPECTRAL DENSITY 45 Report No.: FCC022022-5381RF0 Page 5 of 46 TIRT-TRF/FCC01-2(E):2021A0 Table of Contents Page Report No.: FCC022022-5381RF0 Page 6 of 46 TIRT-TRF/FCC01-2(E):2021A0 REPORT ISSUED HISTORY Report No. Version Description Issued Date Note FCC022022-5381RF0 V1.0 Original Report. 2022.10.20 Valid Report No.: FCC022022-5381RF0 Page 7 of 46 TIRT-TRF/FCC01-2(E):2021A0 1. SUMMARY OF TEST RESULTS Test procedures according to the technical standard(s): FCC CFR Title 47, Part 15, Subpart C Standard(s) Section Test Item Test Result Judgment Remark 15.207 AC Power Line Conducted Emissions APPENDIX A PASS ------ 15.247(d) 15.205(a) 15.209(a) Radiated Emissions APPENDIX B APPENDIX C APPENDIX D PASS ------ 15.247(a)(2) Bandwidth APPENDIX E PASS ------ 15.247(b)(3) Maximum Output Power APPENDIX F PASS ------ 15.247(d) Conducted Spurious Emissions APPENDIX G PASS ------ 15.247(e) Power Spectral Density APPENDIX H PASS ------ 15.203 Antenna Requirement ------ PASS Note(2) Note: (1) “N/A” denotes test is not applicable in this test report. (2) The device what use a permanently attached antenna were considered sufficient to comply with the provisions of 15.203. Report No.: FCC022022-5381RF0 Page 8 of 46 TIRT-TRF/FCC01-2(E):2021A0 1.1 TEST LOCATION Company: Beijing TIRT Technology Service Co.,Ltd Shenzhen Address: 101, 3 # Factory Building, Gongjin Electronics Shatin Community, Kengzi Street, Pingshan District, Shenzhen, China CNAS Registration Number: CNAS L14158 A2LA Registration Number: 6049.01 FCC Accredited Lab. Designation Number: CN1309 FCC Test Firm Registration Number: 825524 Telephone: +86-0755-27087573 1.2 MEASUREMENT UNCERTAINTY ISO/IEC 17025 requires that an estimate of the measurement uncertainties associated with the emissions test results be included in the report. The measurement uncertainties given below are based on a 95% confidence level (based on a coverage factor (k=2)) The TIRT measurement uncertainty as below table: Uncertainty Parameter Uncertainty Occupied Channel Bandwidth ±142.12kHz RF power conducted ±0.74dB RF power radiated ±3.25dB Spurious emissions, conducted ±1.78dB Spurious emissions, radiated (30MHz~1GHz) ±4.6dB Spurious emissions, radiated (1GHz ~ 18GHz) ±4.9dB Conduction Emissions(150kHz~30MHz) ±3.1dB Humidity ±4.6% Temperature ±0.7°C Time ±1.25% Note: Unless specifical…

Text truncated - open the document above for the full version.

Test Setup Photos

BLE SRD

Contact Information

Applicant

Gavin Jiang(CEO)
[email protected]+86-756-8686313Fax: +86-756-8686313

Technical Contact

BTL Inc.Steven Lu
[email protected]86-769-83183000

No.3 Jinshagang 1st Rd, Shixia, · China

Non-Technical Contact

BTL Inc.Rose Liu
[email protected]+8676983183000

Test Firm

Beijing TIRT Technology Service Co.,Ltd ShenzhenQuan Chen
[email protected]+86 150 0208024

Technical Specifications

#Rule PartsFrequency RangePower Output
215C2.40 GHz - 2.48 GHz200.00 µW
Confidentiality
Long Term
Grant Notes
Output power listed is conducted. End-users must be informed of transmitter operating conditions for satisfying RF exposure compliance.

Other Applications from Zhuhai Hoksi Technology CO.,LTD

K610w Corona Wireless Mechanical Keyboard - FCC ID 2AXCA-K610WCORONA - Zhuhai Hoksi Technology CO.,LTD
2AXCA-K610WCORONA

K610w Corona Wireless Mechanical Keyboard

Oct 29, 2023

Equipment Class

DTS - Digital Transmission System
K620w Corona Wireless Mechanical Keyboard - FCC ID 2AXCA-K620WCORONA - Zhuhai Hoksi Technology CO.,LTD
2AXCA-K620WCORONA

K620w Corona Wireless Mechanical Keyboard

Oct 29, 2023

Equipment Class

DTS - Digital Transmission System
DGK710 Wireless Mechanical Keyboard - FCC ID 2AXCA-DGK710 - Zhuhai Hoksi Technology CO.,LTD
2AXCA-DGK710

DGK710 Wireless Mechanical Keyboard

Jul 30, 2023

Equipment Class

DTS - Digital Transmission System
The third mock examination mechanical keyboard - FCC ID 2AXCA-TGK200 - Zhuhai Hoksi Technology CO.,LTD
2AXCA-TGK200

The third mock examination mechanical keyboard

Feb 13, 2023

Equipment Class

DTS - Digital Transmission System
K330w Plus Wireless Mechanical Keyboard - FCC ID 2AXCA-K330WPLUS - Zhuhai Hoksi Technology CO.,LTD
2AXCA-K330WPLUS

K330w Plus Wireless Mechanical Keyboard

Dec 21, 2022

Equipment Class

DTS - Digital Transmission System